I controled voltage output by vertical pointer slide In my vi.Now,I try tocontrol it by a series accurate values. I want to get output according to the array's value.

I controled voltage output by vertical pointer slide In my vi.Now,I try to
control it by a series accurate values. I want to get output according to
the array's value.
Attachments:
input+output.vi ‏51 KB

Yun,
Here's a simple example I wrote that does what you are trying to do. You can wire an array into an Analog Out 1D DBL 1 chan N Samples. Then I wired the size of the array into the number of samples per channel on the timing vi.
Regards,
Danny F
Danny Funk -- Staff Product Support Engineer -- InsightCM R&D -- National Instruments
Attachments:
AnalogOut Array.vi ‏20 KB

Similar Messages

  • On slide No. 13 of my Keynote presentation, I have varous pictures that go through automatically just as I programmed them, but if I I want to get by clicking to the next slide , it does not let me. How can I program so when I want goes to next slide?

    On slide No. 13 of my Keynote presentation, I have varous pictures that go through automatically just as I programmed them, but if I I want to get by clicking to the next slide , it does not let me. How can I program so when I want goes to next slide?

    Keynote is programmed to execute all of the effects in a build sequence before it will move to the next slide.
    If you want tobe able to move to the next slide at any time in a sequence of builds, you will need to set all of the builds on that slide to:  "on click". You will then need to execute each build by pressing the space bar or click the left mouse button for each object.

  • I just have a big explanation point on a black screen when I try to open on of my little photos  how do I get my picture back

    I can not get some of my pictures on I photo to come up in a slide show or enlarge them  the screen just turns black with a big explanation mark where the picture should be...as soon as I take it bak down it shows up in my photo line up  how do I get this explantion point to disappear and my picture back????

    What version of iPhoto?
    The general answer is to back up your iPhoto library, depress the command and option keys, launch iPhoto and rebuild your library
    LN

  • How to control HV power supply (0-5V control voltage)?

    Hey there,
    I (LV newbie) wonder how to control my DELTA ELEKTRONIKA Powersupply with Labview. The control interface is a 0-5V analog input to set the power supply's output current.
    Also I want to get some feedback of the set power supply current from an second (GPIB-controlled) instrument.
    So how do I have to program a closed loop contol (application is not time critical), cause it would be mixed up of controlling by analog out (0-5V) and feedback loop driven on the GPIB-Card? 
    For a first step a simple control loop to set the current and monitor it on an analog input would also be an assistance .
    THX for anyone helping

    Look in the example finder for DAQmx functions for analog input and analog output.

  • I am extremely upset. I purchased my iPad in SA and I am traveling in Greece. When I want to make use of the free apps, I get a message that the app is not available in the SA store. What is the point of having an iPad if you cannot use it worldwide?

    I am extremely upset. I purchased my iPad in SA and now I am in Greece. I cannot download free apps as I get a message that the apps are not available in the SA store and only in US stores. When I change to the US store the same thing happens. What is the point of having an iPad if I cannot use it worldwide??? I feel that I wasted my money purchasing it as I specifically purchased it to use when I travel. How can I get access to all the available apps and why are they restricted.

    You can use your iPad worldwide. However, each AppleID is tied to
    a specific country's store. To use the AppStore in any country, you
    must be in that country and have a credit/debit card issued by a financial
    institution in that country with a verified billing address in that country.
    It is the developer's choice which AppStores he makes his app available
    from, and some countries prohibit certain apps.
    To make a purchase from the US store (including downloading a free app
    available in the US store), you must be in the US and have card issued
    in the US with verified billing address in the US.
    You can use your purchases from the SA store worldwide, but you
    cannot make purchases in other than the SA store unless you meet
    the aforesaid conditions.

  • How do I get routing data from the Map App (powered by TomTom) so I can display the point-to-point annotations (turn-by-turn navigation) without leaving my own application.

    I have a tableView displaying a list of contacts from a Cloud Database.  After selecting a contact, I push to a programmatically created MKMapView.  Then I display the initial region (the view) that includes the users current location (starting point) and their selected destination (end point).
    Now I want to display annotations (as described in the Location Awareness Programming Guide) that displays polylines which will represent the turn-by-turn navigation IN MY OWN APPLICATION, and not in the Map App currently used in IOS6. 
    Due to licensing and its becoming depricated in IOS 6, I do not want to get routing data from the Google Maps API.  How do I get routing data from the IOS 6 Map App (powered by TomTom) so I can display the point-to-point annotations (turn-by-turn navigation) without leaving my own application?
    I checked out Stack Overflow and other forums which basically left me with the impression that this is not possible. I also checked out the TomTom iPhone Mobile SDK User Guide from the TomTom Developer Portal and am still confused.  It must be possible to retrieve routes, since the Map App can display turn-by-turn directions.  How can I retrieve turn-by-turn data that I may display as a route within my own application?

    Thanks Michael. Apologies for the slow reply I was away for a bit (holiday blitz at work and visiting family madness etc.etc.) back now, I set both options you requested to "never " and retried the CMS software with no change. 
    I do have progress of a sort though, as a test I took a separate test PC and put a clean install of Win7 on and loaded up the CMS software (it worked perfectly) and then took the version of ole32.dll off that machine and put it onto the computer I had built
    for her (using Linux) and...
    got a new error code. Darn I was so sure I had found a clever solution this time lol.
    Anyway now when the CMS fails it gives me a similar error but the offending module is "ntdll.dll" sooo... I tried taking the "working" version of ntdll.dll from the test box and moving it over (making sure to back up the existing ones
    first so I could put them back if needed) to her new PC and the PC would not boot. 
    It seems to want the original versions of a few Dynamic Link Libraries and if I could somehow give it those while not breaking Win7 it should theoretically work seeing as it no longer errors with ole32.dll. 
    ntdll.dll however seems necessary for Win7 to boot.
    So what I am wondering now is:
    Is there some way to have both versions of the DLL file in the system32 folder (bypassing the "cannot have two files with the exact same name in the same folder" thing) or rename the original DLL's something else and somehow make the CMS look for
    the new named versions so the system has the updated DLL's it needs to boot/run and the CMS has the old ones it wants to run or is there someway to have a self contained install of the CMS, say on a USB flash drive and give it it's own E:/windows/system32/needed
    dll's  path to the files it needs? 
    Willing to try any other options or settings you may have come up with as well.
    Thanks again for your reply and my apologies for not answering sooner.

  • How to use a Time - Voltage Array to Control a Analog Voltage Output using DAQmx Write VI

    I have an array of Time values associate with Voltage values that I want to use to control a Anolog Votage Out Device (PXI-6251) using DAQmx.  The array contains 1,000 elements.  The time values are NOT evenly spaced, the rate changes through the array.  The array is output once, timed to other processes.
    My problem is I haven't been able to locate a reference on how to handle the timing variability in the array.  If time was equally spaced I could use a loop....
    The attached showes the array, first row is time (ms) and the second row is voltage (volts).
    Can someone point me in the right direction?
    David
    Attachments:
    TimeVoltage.png ‏11 KB

    David,
    if you have only Base version of LabVIEW, this will be a time consuming task.
    If you have either Full or Professional, you will find interpolation-functions in the mathematic palette.
    I am not sure which ones serves you best,  but i'd startexperimenting with Interpolate 2D.
    hope this helps,
    Norbert 
    [Edit]: You could also use a polynominal fit on your voltage values. You will get a function describing the voltage over time. But you will have to modify this function to take care of the variation of time spacing. If you have a function describing your voltage over your (nonconstant) timestamps, you can simply create values for constant timeslices for your voltage.
    Message Edited by Norbert B on 11-06-2008 10:21 AM
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • I'm working on DC Motor control using DAQ. There is sufficient voltage output from DAQ but not current. What should i do so as to drive the motor

    I'm working on DC Motor control using DAQ. There is sufficient voltage output from DAQ but not current. What should i do so as to drive the motor. Could you suggest me appropriate driver IC using which this problem can be solved.
    Saravanan.T

    You really should use a DC motor controller to control a DC motor, look at the 754410 IC for a good example. You should be able to interface these to most DAQ devices.
    Alan

  • Controlling XML output Livecycle Designer 8.0

    Hello.
    I am new to XML and somewhat new to LiveCycle Designer, however I have acclimated rather well.
    Here is what I want to do:
    1) Create a PDF fill-in-form (including various fields...text, numeric, radio buttons, and some FormCalc functions)
    2) Create a Submit button that emails an XML file to the form administrator
    3) Use MS Excel to import XML files into pre-mapped fields
    Basically, I do not have server database support, and this is the best workaround (and most functional) I could come up with.
    After mapping fields in Excel, I exported the *.xsd and created a new data connection within LiveCycle. Then, I linked the schema fields with the bindings - corrected any errors, and have tested the form (form1). I made the submit button - that's all good, too. When I import the XML into Excel - that's where I have a problem, and it's not an issue with Excel to my knowledge, but rather how the form generates the XML output.
    For example, I have 25 fields that will be outputted via XML. My PDF form consists of 4 pages (8.5" x 11"). When I created the form and got to the end of the page, I "inserted new page" and went on my merry way. When I import the XML, Excel properly maps the fields, however, it does not import the info to a single row. What I have discovered is that since my PDF form consists of 4 pages (each bound to "sheet[*]"), the XML output looks like the following:
    Example of the XML output from my form:
    <form1>
    <sheet>
    <submissionID xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    >743</submissionID>
    <reviewerID xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    >234</reviewerID>
    <date xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    >24/01/2008</date>
    </sheet>
    <sheet>
    <tag1>input</tag1>
    <tag2>input</tag2>
    </sheet>
    </form1>
    Wherever there is a "<form>" tag (hence a new page in my PDF document), Excel puts that data on a new column. All fields within form1 are imported and mapped to the correct field, however importing a single XML file will occur on 4 rows.
    I bound each "page" as "sheet[*]" mostly because that is the only way I knew how to use FormCalc to do calculations from fields that occur at different places throughout the document.
    So, I have tried to be as clear as possible, and would like suggestions/help as how to control the XML output from a LiveCycle document. If I am to modify the outputted XML and remove the multiple instances of <sheet> and </sheet> then Excel imports the data just fine and on a single row.
    I would love some help on this rather specific problem. I guess it's a very basic issue that someone with experience could help.
    Thank you so much!!
    Jim

    I have a vital form that clients fill out, which is passed to many people in the company along the workflow. The form is a Planner and we have in the following PDF, Word Doc..
    Well before, the Planner.pdf was originally created in Word, since most people have access to Word.. but evolved to a PDF form created from the Word Doc via Adobe LiveCycle Designer 8.0 w/ User Rights enabled so that the form could be filled out and saved using Adobe Reader.. which was a step better than Word.. being that it is free. But this needed to be easier and more to the point b/c some clients don't particularly like installing the latest version of Reader, even if you provide them the link. Nor do they like saving the form, filling the form, and attaching the form to send back.
    My goal is to have the client fill an HTML version of the form, submit and be done with it, but everyone in the workflow be able to easily receive the filled Planner as a PDF form.
    So some months ago I ran into this post Chris Trip, "Populate Livecycle PDF from mySQL database using PHP" #8, 22 Sep 2007 4:37 pm
    which uses the command line Win32 pdftk.exe to merge an FDF file into an existing PDF on the remote server, and serve this to whoever.
    My problem was with shared hosting and having the ability to use the Win32 pdftk.exe along with PHP which is predominantly used on Linux boxes. And we used a Linux box.
    so i created the following unorthodox method, which a client fills the HTML version of the Planner, all field values are INSERTED into a table in MySQL DB, I and all filled planners that have been filled by clients to date can be viewed from a repository page where an XML file is served up of the corresponding client, but someone would have to have Acrobat Professional, to import the form data from the XML file into a blank form.. altoughh this is simple for me.. I have the PHP file already created so that when a Planner is filled and client submits. >> the an email is sent to me with a table row from the repository of the client name, #, email, and a link to d-load the XML file,
    But I also have the PHP files created so that the Planner can be sent to by email to various people in the workflow with certain fileds ommitted they they do not need to see, but instead of the XML file beiong served up i need the filled PDF Planner to be served.
    I can do this locally with ease on a testing server, but I am currently trying to use another host that uses cross-platform compatibility so i can use PHP and the pdftk.exe to achieve this, as that is why I am having to serve up an XML file b/c we use a Linux server for our website, and cant execute the exe.
    Now that I am testing the other server (cross-platform host), just to use them to do the PDF handling (and it's only $5 per month) I am having problems with getting READ, WRITE, EXECUTE permissions..
    Si guess a good question to ask is can PHP do the same procedure as the pdftk.exe, and i can eleminate it.
    or how in the heck can i get this data from the DB into a blank PDF form, like i have described??
    here are some link to reference
    Populating a LiveCycle PDF with PHP and MySQL
    http://www.andrewheiss.com/Tutorials?page=LiveCycle_PDFs_and_MySQL
    HTML form that passed data into a PDF
    http://www.mactech.com/articles/mactech/Vol.20/20.11/FillOnlinePDFFormsUsingHTML/index.htm l
    and an example
    http://accesspdf.com/html_pdf_form/

  • Why Levels mid-point slider and Exposure Gamma Correction slider not the same?

    Both the mid-point slider in Levels and the Gamma Correction slider in Exposure adjustment appear to modify Gamma.  They even use the same numeric scale.
    When Gamma <= 1, both sliders appear to produce the same results (confirmed with a couple of random sample settings and using the Difference blend mode).
    When Gamma > 1, however, the results are very different.  Levels produces more what one would expect in terms of moving the Gamma curve without moving the white and black points but the Exposure Gamma Correction slider seems to do something very different, either moving the black point or applying a very different curve the produces much brighter tones in the dark shadows.
    Can anyone explain why and how these two adjustments produce different results?
    Is this a bug with the Exposure adjustment?
    By the way, in my limited tests of this I was just using a standard RGB file in 16-bit mode - nothing fancy like 32-bit or LAB or anything like that.  Also, Photoshop CS6 Extended.  Both 32- and 64-bit versions show the same behavior.
    Thanks.

    The differing gamma adjustment results also occur in the OS X version of Ps 13.0.1
    The situation is worse than you realize, Dennis. Test with a linear grayscale gradient in 16-bit or 8-bit RGB mode instead of arbitrary images. Remember to view at 100% zoom for an accurate display.
    Gamma adjustments of less than 1 performed by Levels adjustment layer and Exposure adjustment layer do differ but to a less obvious extent than when the adjustment is greater than 1. Differences can be seen in histograms, and low level differences when differencing layers can be made more obvious by adding an Exposure adjustment layer with the exposure increased.
    You'll get further different results by using the gamma adjustment in the "Exposure and Gamma" method of Image > Adjustment > HDR Toning. Notice that the gamma value there has to be specified as the inverse of that in Levels and Exposure.
    I haven't bothered to calculate which, if any, of the three gamma adjustment controls gives correct results because that is Adobe's responsibility.
    It's quite ridiculous that a common routine giving consistent and correct results isn't being used for all these gamma adjustments. Code re-use makes software more robust, simpler to test, simpler to correct, leaner and overall easier to manage. But what do I know.

  • Is there a way to replace a Power Point slide in Captivate and keep the CC notes?

    Hello,
    I have a lot of Power Point slides in my Captivate project. The Power Point presentation is on a Share Point, so it is impractical to "link" the Captivate project with the Power Point presentation.  Now and then we need to make changes to the Power Point slides and then replace the old slide in Captivate with the new slide.  We have a lot of CC notes and TTS attached to each slide, so I lose all of that when I replace the slide.  Is there a way to keep the synchronized CC and TTS notes in place, and just replace the acutal slide?
    Thank you!
    Ryan

    1 - simplest way:
    drag the sound file on to the audio well in the Inspector > document > document tab
    music can only start on the first slide and will play untill the music ends, you can only have one music file in the presentation
    2 - more control
    drag the sound file on to any slide, add the  images on to the same slide and use Builds to reveal each image in turn

  • Odd appearance of horizontal pointer slide

    Hi, anyone have any ideas why Horizontal Pointer Slide numeric controls seem to display oddly when I have the Full Markers/Full Ticks selected?  (see the attached image).  For some reason all but the right-most marker have a bold appearance.  I don't have the font set to bold.  
    This happens at run time, but also can be seen in the UIR editor.  I've attached a UIR file to this message.
    I'm using CVI 2010 SP1, on Windows 7 x64 Professional.  Aero is turned on.
    Thanks for any help.
    Attachments:
    slider.uir ‏3 KB

    Hello -
    This is unfortunately a known issue, and a result of enabling Microsoft ClearType.  To work around this, you can either disable ClearType or disable full tick marks.
    I'm sorry for any inconvenience -
    NickB
    National Instruments

  • Control analog output based on analog input

    Dear forumers,
    I am pretty new to the labview programming so excuse me if this was posted before.
    I use: Labview 8.5 + PCI 6229
    I want to create a real time feedback: to control analog output based on analog input. The task is very simple - if the ai1 (analog input 1) voltage is larger than a constant, then decrease the voltage of the ao1 (analog output 1) by a constant. Otherwise increase the voltage of ao1 by the same constant.
    All should work for 10 seconds.
    I have tried to implement this using 2 daq asistants and various methods. The problem is that I get the whole signal recorded from the ai1 ( 10 seconds) and then modified and released to the output (another 10 seconds). The execution takes 20 seconds instead of 10 and it is not realtime at all.
    Is it a must to make vi in "run continuous" mode to make it work ?
    Please help :}.
    I am attaching 2 examples.
    1. Main idea what I am trying to accomplish
    2. Very simple example that still does not work in real time simultaneously.
    Attachments:
    example-main.vi ‏180 KB
    example-simple.vi ‏147 KB

    nooto wrote:
    Thank you for your suggestion.
    I understand the simple arithmetic you are talking about. However I do not understand why it takes 20 seconds instead of 10 to complete the task. In other way to say - why it reads the whole input first (10 seconds) then write the output ( 10 seconds).
    Why doesn't ir read and write simultaneously?
    If I use Elapsed Time function - what feedback response time can I expect ? Is it good to use Elapsed Time if i need fast response time? In my application i would I need about 1 milisecond response time. Currently in the example the rate is 50 Hz, later I would like to change the rate to 1000.
    You simply don't understand the underlying paradigm of LabVIEW -
    dataflow. You have a dependency between the first DAQ Assistant and the
    second. The second simply will not start until the first finishes. There
    is no way around that given your condition that the output depends on
    what you read.
    If you want 1 millisecond response time then you will have to swithc to a real-time OS. Windows does not have that kind of resolution and there is way to much jitter.

  • Correct dimensions for Power POint Slides

    What would you all recommend for dimensions for Power Point slides so that they fill up the screen
    with no border. My customer is cramming too much text on each slide and it is beyond title safe, going to near edge of TV screen upon viewing.
    I have sequences that are both 16 x9 (720 x 480) and 4 x3 .
    Thanks,
    Al

    I agree with that much text it is not looking good on the TV that I am testing it on. On computer it is better. I thought about the color layer below the slide but the design of the slide has 2 color boxes, (one horizontal, one vertical) on it and putting a layer below doesn't look good so far.
    I am probably going to have to edit each slide and shrink the font and increase the borders.
    I am talking to the admin who made them today.
    A bigger problem is that they have trouble playing the DVD's I make with iDVD in their PC environment. The DVD's either play jerkily or not at all compounded by the fact that the people have lost all the remotes to their DVD players and can't pick a chapter. So I am trying to come up with work around.
    Thanks for response,
    Al

  • How to convert a voltage output from a Rogowski coil to its original current waveform ?

    I need to measure current using a Rogowski coil. The voltage output of the coil across a 1k load resistance is directly proportional to the "rate of change of current" flowing through the conductor passing through the center of this coil. So the output is actually :
    y = M * di/dt ; where M is the mutual inductance of the coil.
    I need the output waveform as i(t). This means an integration is required.
    Can some one help me out with this ?
    I am also told that in the frequency domain this integration means a -20dB/decade attenuation and a constant -90 degree phase shift. This is some thing I cannot work out with Labview since I am new to it. I tried a mathematical integratio
    n. But this also does not work.
    Could someone help me out with this ?
    Regards
    PC

    To come up with the most straight forward approach, forget for a moment that you are using LV and think about how you would calculate the answer using paper and pencil.
    You have an input value that (using the formula you gave) is related to the rate change for a parameter (in this case the current). Given that rate of change, how do you calculate the absolute value of the parameter at any given point in time? It's really just a math problem...
    Once you have it worked out on paper, just do the same calculations in LV.
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

Maybe you are looking for

  • Date and Time generation

    hi, I need to "Generate Date and Time between two date ranges" ie For Example if my start date is 12/Jan/2007 00:00:00 AM and end Date is 13/Jan /2007 00:00:00 PM. i need to generate my output as Date 12/Jan/2007 00:00:00 12/02/2007 00:01:01 12/03/20

  • Sending a document as an mail attachment with approve and reject button

    Hi all,      i have an infopath form where a user fills the form and on submit the form is saving as an document in the document library, now my question is, how can i get this document as an mail attachment with approve and reject option.

  • How to create billing document  in VF01 without Excise duties. ?

    Dear All , Here is a scenario that we had done the Goods rcv of a  material without capturing   any excise entry as this material is non excisable , Now an ETO is created  for a  party , After this user   wants this material  to be given to Customer

  • Is there a weblogic 11gr1(10.3.6) plugin for apache 2.4 on windows

    I need to find out what version of Web Server Proxy Plugin is the correct one to work with WebLogic Server 11gr1 (10.3.6) and Apache webserver 2.4. WebLogic Web Server Plug-In 12c  indicates that  it is backward compatible with WebLogic Web Server Pl

  • EA1 - SQL History Timestamp format

    Feature Request "SQL History Timestamp - NLS Date format" (Use the current NLS Date or Timestamp Format preference for formatting the Timestamp displayed in the SQL History window) is listed as Scheduled for 1.5 but has not been included.