[IDOC] WE19 send successfully ...but where it is?
Hi,
creating scenario IDOC -> XI -> File with own IDOC.
After sending it with we19 he said "IDoc sent to SAP system or external program".
In we02 and we05 the IDOC it says "Data passed to port OK".
Business Systems:
Sender : SAPBS Client 200
Receiver: SAPXI Client 001
(Both on same SAP server)
But it never appears in sxmb_moni nor a file is created on receiver system.
How to debug where the error could be?
-RWE doesn't show an error in adapter monitoring.
-Destination is tested successfully
What else?
thanks
chris
Ok, my fault. Looking in XI client for sm58. In Busines system I found IDOCs with following error:
"Transaction IDX1: Port SAPERP_200, client 200, RFC destination contain e"
I think this shoul mean error. But why?
I checked [this guideline|https://wiki.sdn.sap.com/wiki/pages/viewpage.action?spaceKey=XI&title=SAPR3%28Idocs%29ToXI--Steps+Summarized&decorator=printable]
It seems he tries to use a port for ERP_200 (R/3 System), but I think he shouldn't or?
My configuration again:
R/3 system
sm59: ERP_00_001
we21: P_XI_OB (using destination ERP_00_001)
BD54: ERP_00_001 (XI System)
WE20: ERP_00_001 using my Message Type ZPersonal_Test with Receiver port P_XI_OB)
XI system
sm59 : ERP_00_200 (is this for sending back acks or to get meta data?)
idx1: Port: SAPERP Client: 200 Destination ERP_00_200)
IDX2: SAPERP - IDOC Type: ZPersonal_Test - Client 200
While collecting these information I found following:
- My BS for SAP XI (client 001) have no logical system name. The technical system
got ERP_00_100, but the BS didn't take it. How to insert it?
But if this is the error, why he said error in SAPERP_200 ?
- Why I have to use two different transaction (we21 in R/3 and IDX1 in XI)
for creating ports. What's the different?
thx
chris
Similar Messages
-
IDOC Inboun processing success but no record posted to table
Hi,
We are performing ALE refresh in RCD221 (development system). The ALE IDOCS are extracted for HR area with Message class as HRMD_A, the IDOCS are processed successfully from the sending system (RCB) and reaches the receving system RCD221. While we process the inbound IDOCS in RCD221 records are not getting posted in the table, however the IDOC status is shown as successful (53). This is happening when we are processing the data for object type 'P'.
Regards,
Bharath Mohan B.RFC destinations, Logical systems, and then Partner profiles needs to be maintained. and You need to create the Distribution model in sender system.
Partner profiles maintained in both the systems, soure Outbound properties
Target Inbound properties.
if you have two clients in system it will be easily you can check. -
I installed windows 7 on my macbook pro. all is working but lan adaptor and sound od laptop is not working. please help me or send the link where i can download the these drivers.I have lost my resource cd .
If you are running Lion or Mountain Lion, the drivers are downloaded from within Bootcamp Assistant. If you are running Snow Leopard the drivers are on your Snow Leopard install disk.
Read the Bootcamp Install Guide for your version of OSx. http://www.apple.com/support/bootcamp/
Bootcamp questions should be asked in the Bootcamp forum where the Bootcamp gurus hang out https://discussions.apple.com/community/windows_software/boot_camp -
I got this problem when I tried to configure out-going email and add an account to farm administrator group.
I configure out-going email according to this website http://technet.microsoft.com/en-us/library/cc288949.aspx
Here are the screen shots.
The SMTP server and email accounts work out OK when I use Outlook 2010 to test.
Anyone can help me about it? Thanks.
Here is the log.
09/20/2012 09:21:00.36 w3wp.exe (0x1F7C)
0x1138
SharePoint Foundation E-Mail
8gsf
High
#160008: The e-mail address 'admin3.sharepoint@domain' contains illegal
characters. df98555c-612f-4a58-9443-ab6e9a4fcc53
09/20/2012 09:21:00.36 w3wp.exe (0x1F7C)
0x1138
SharePoint Foundation General
8kh7 High
Cannot complete this action. Please try again.
df98555c-612f-4a58-9443-ab6e9a4fcc53
09/20/2012 09:21:00.36 w3wp.exe (0x1F7C)
0x1138
SharePoint Foundation E-Mail
7946 Critical
Cannot complete this action. Please try again.
df98555c-612f-4a58-9443-ab6e9a4fcc53
09/20/2012 09:21:00.36 w3wp.exe (0x1F7C)
0x1138
SharePoint Foundation Runtime
tkau Unexpected
Microsoft.SharePoint.SPException: The user or users have been added successfully, but there was an error in sending the e-mail message. The server may not be set up correctly to send e-mail. To verify that e-mail is configured correctly, contact your
server administrator. at Microsoft.SharePoint.ApplicationPages.AclInv.SendEmailInvitation(EntityEditor picker, String subject, String message) at Microsoft.SharePoint.ApplicationPages.AclInv.BtnOK_Click(Object sender, EventArgs e)
at System.Web.UI.WebControls.Button.OnClick(EventArgs e) at System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(IPostBackEventHandler sourceControl, String
eventArgument) at System.Web.UI.Page.ProcessRequestMain(Boolean includeStage...
df98555c-612f-4a58-9443-ab6e9a4fcc53
The e-mail address I have tested it for several times and there is no problem.
Anyone has any clue about this error?Hi.
This I have seen before...
It can be that the SMTP relay server is configured to only allow certain IP ranges or addresses.
It can be that the firewall on the SP server does not allow for SMTP traffic (normally 25, for example for Exchange).
It can be that there is an Antivirus on the SP server(Client AV) that prohobits the Timer service to send email from this server. I have seen MacAfee do this. Needed an policy change.
If, its the builtin SMTP service you are using, check this link:
http://blog.sharepointrx.com/2010/11/18/setting-up-the-iis-smtp-server-for-sending-email-from-sharepoint-2010-on-server-2008-r2/
Check that and try again.
Regards
Thomas Balkeståhl - Technical Specialist - SharePoint -
http://blog.blksthl.com
Download the SharePoint Branding Project here
Download the SharePoint 2010 Site Settings Explained here -
Scenario is HTTP to db. In HTTP client, when Sender is Business Component, Pi is getting data successfully but when Business system is used as sender Pi is not getting any message in sxi monitor. Please help
Hi Ankita,
Try to trace at ICM level, Go to smicm transaction
Set level to 3.
Later send your request. Finally trace the request in:
When you have seen the log, check if any exception is raised with your request or the request and share it here.
Regards. -
i have scenario SOAP to IDOC
when i'm using business service in sender side it is getting an error as follows
sender message can not convert to ALE Logical system
in this i'm using altova spy as testing tool
my sender interface is asynchronous
but when i'm using business system everything is working fine
In sender side i'm using soap adapter,i checked the logical system everything is fine
mainly the problem is why it is working when i'm using business system rather than business service
my pi version is pi 7.0
thanks in advance
regards
satishHi Satish,
You are sending IDOC's to SAP system right. we should create Business system not business service.
so we should create the business system as web AS ABAP in SLD and import the same in ID.
When we create the business system in SLD the logical system name is assigned for the business system. like SAPCLNT100...It plays a key role in IDOC scenarios.
sender message can not convert to ALE Logical system
Reasons for this issue is
1) logical system name is unable to read from SLD for that corresponding business system.
Goto business system click on Adapter specific identifiers from the menu --> read from SLD.
it will automatically fetch the logical system name from the SLD.
2) Sometimes the logical system name will be deleted from the business system in SLD.
Delete the business system and re-create it, and follow the above procedure.it will resolve your issue.
Regards
Bhargava Krishna -
i have final cut pro x-i have been using the share button previously and had no problem.as of today i share a movie to 720hd, and after a while it says share successful but i cannot find where the movie has been saved???need help--i cannot find the destination. can this be changed.it used to go to itunes, home video.thanks, dimitrios
EExactly what settings are you using. Some go to iTunes.
-
IDOC: Status (Error/Success/information)report to Sender system
How would one send a message(error/success/information) to the sending(external) system to inform them of the statuses of the messages they've sent to our SAP system?
Hi Baumann,
you have an option called Audit reporting in which you can have the status of idoc at sender side.read the following.
Setting Up Audit Reporting
In the default behavior, after an IDoc is dispatched to a destination system, the sender does not know the state of the process on the destination system. You can configure the system, however, for cross-system reporting. You must model the ALEAUD message between the systems.
Two programs enable cross-system reporting.
1)RBDSTATE. This program is scheduled to run periodically on the destination system. It reports the status of incoming IDocs to the sending system, using the ALEAUD message and ALEAUD01 IDoc. This status information is recorded separately from IDoc status information in the audit logs.
2)RBDAUD01. This program is executed on the sending system. It analyzes the audit log and displays the output as a report.
The RBDSTATE program returns the following statuses, from the receiving to the sending system.
RBDSTATE Is Run on the Receiving System
Status of IDoc in receiving system Status reported to sending system via ALEAUD
53 (Application document posted.) 41 (Application document created in receiving system.)
51 (Error: Application document not posted.) Status 39 (IDoc is in the receiving system.) This status is repeated each time RBDSTATE is run, as long as the IDoc remains in status 51.
68 (Error: No further processing.) 40 (Application document not created in receiving system.)
reward points if helpful, -
I am sending internal tabledata as a email body successfully.But how displa
I am sending internal tabledata as a email body successfully.But how i display the headings in that email.can anyone suggest?
you can append some space in between heading line and subject like below..
Heading
objtxt = ' I AM SAP USER'.
APPEND objtxt.
APPEND objtxt.
APPEND objtxt.
APPEND objtxt.
after Heading...
objtxt = ' i am part of the abap.......'.
APPEND objtxt. -
Migration Assit , PC to MAC - The migration was successful, but I don't know where the files are. It says they're under a different user, 'owner' . I tried to access via sys pref/system/users&groups, but it asks for a password for owner which I don't have. What must I do to access my files?
My experience is with MS PC's I'm new with the MAC Book Pro.Then, see if this works:
Mac OS X 10.6 Help- If you forget your administrator password
If you are running Lion or Mountain Lion you may need to do the following to access the same utility:
Boot to the Recovery HD:
Restart the computer and after the chime press and hold down the COMMAND and R keys until the menu screen appears. Alternatively, restart the computer and after the chime press and hold down the OPTION key until the boot manager screen appears. Select the Recovery HD and click on the downward pointing arrow button.
When the menubar appears select Terminal from the Utilities menu. Enter resetpassword at the prompt and press RETURN. Follow instructions in the dialog window that will appear.
Or see Reset a Mac OS X 10.7 Lion Password and OS X Lion- Apple ID can be used to reset your user account password. -
When I download a document, I get a message saying download was successful, but a blank screen where the document should be. What am I doing wrong?
I go to an internet company and try to download a document from it. A tab pops up saying the download was successful, but all I see is a blank screen with UI at the top. I don't understand where the download is going.Thanks so much for your reply fanboy20.
Yes, just made sure of that. I do have the latest version of Flash player. But I have just staggered upon the answer. Chalk it up to being a newbi. I was not putting my apple tv to sleep and it would not allow me to see
you tube on my computer while it was still operating on my TV. When I realized that, I put the apple tv to sleep and bingo, my computer runs you tube fine. Thanks again for your response. -
HT5312 ok but where do i go to send me rescue email so i can retrive the ans
ok but where do i go to send me rescue email so i can retrive the ans
If you have already have a rescue email address (which is not the same thing as an alternate email address) set up on your account then you can try going to https://appleid.apple.com/ and click 'Manage your Apple ID' on the right-hand side of that page and log into your account. Then click on 'Password and Security' on the left-hand side of that page and on the right-hand side you might see an option to send security question reset info to your rescue email address.
If you don't have a rescue email address then see if the instructions on this user tip helps : https://discussions.apple.com/docs/DOC-4551 -
Service Pack for Proliant installing successfully but returning failure in OSD task sequence
Building bare metal servers with SCCM 2012 SP1 CU2 OSD and running into an issue with HPs where they attempt to install the Service Pack for Proliant 2013.02.0. I am using a package with a program. Here is the program command line:
Hpsum.exe /use_latest /allow_non_bundle_components /current_credential /silent
The application installs successfully but there is a distinct delay and then errors thrown that fails the TS. Setting 'continue on error' is a work around but not what I want to have in the production environment. How can I get around this issue?
This is the same exact package and program that ran perfectly fine in SCCM 2007, but we are seeing this as a new issue since the migration to SCCM 2012.
I'd like to solve this issue as well as get rid of the "Waiting for job status notification....InstallSoftware"
Any suggestions?
SMSTS.LOG
Invoking Execution Manager to install software InstallSoftware
12/3/2013 9:59:49 AM 1568 (0x0620)
Installing software for PackageID='WCD002D2' ProgramID='Silent install' AdvertID='WC120008' has started, jobID='{8B4082A9-9477-4D1F-9DEC-6A3F19EC3F6F}'
InstallSoftware 12/3/2013 9:59:50 AM
1568 (0x0620)
Setting TSEnv variable 'SMSTSInstallSoftwareJobID_WCD002D2_WC120008_Silent install'='{8B4082A9-9477-4D1F-9DEC-6A3F19EC3F6F}'
InstallSoftware 12/3/2013 9:59:50 AM
1568 (0x0620)
Waiting for installation job to complete.. InstallSoftware
12/3/2013 9:59:50 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:00:20 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:00:50 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:01:20 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:01:50 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:02:20 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:02:50 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:03:20 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:03:50 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:04:20 AM 1568 (0x0620)
Launching command shell. OSDSetupHook
12/3/2013 10:04:25 AM 2696 (0x0A88)
Windows station: WinSta0 OSDSetupHook
12/3/2013 10:04:25 AM 2696 (0x0A88)
Desk"Apple-tab-span" style="white-space:pre;"> OSDSetupHook
12/3/2013 10:04:25 AM 2696 (0x0A88)
executing command: C:\WINDOWS\system32\cmd.exe /k
OSDSetupHook 12/3/2013 10:04:25 AM
2696 (0x0A88)
executed command: C:\WINDOWS\system32\cmd.exe /k
OSDSetupHook 12/3/2013 10:04:25 AM
2696 (0x0A88)
Waiting for job status notification... InstallSoftware
12/3/2013 10:04:50 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:05:20 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:05:50 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:06:20 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:06:50 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:07:20 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:07:50 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:08:20 AM 1568 (0x0620)
Waiting for job status notification... InstallSoftware
12/3/2013 10:08:50 AM 1568 (0x0620)
CompleteExecution received InstallSoftware
12/3/2013 10:09:00 AM 3320 (0x0CF8)
CompleteExecution processed InstallSoftware
12/3/2013 10:09:00 AM 3320 (0x0CF8)
Received job completion notification from Execution Manager
InstallSoftware 12/3/2013 10:09:00 AM
1568 (0x0620)
Installation completed with exit code 0x80070001
InstallSoftware 12/3/2013 10:09:00 AM
1568 (0x0620)
Installation failed with error (0x80070001)
InstallSoftware 12/3/2013 10:09:00 AM
1568 (0x0620)
Setting TSEnv variable 'SMSTSInstallSoftwareJobID_WCD002D2_WC120008_Silent install'=''
InstallSoftware 12/3/2013 10:09:00 AM
1568 (0x0620)
GetExecRequestMgrInterface successful InstallSoftware
12/3/2013 10:09:00 AM 1568 (0x0620)
Releasing job request, jobID='{8B4082A9-9477-4D1F-9DEC-6A3F19EC3F6F}'
InstallSoftware 12/3/2013 10:09:00 AM
1568 (0x0620)
Releasing of Job Request successful InstallSoftware
12/3/2013 10:09:00 AM 1568 (0x0620)
CompleteJob successful InstallSoftware
12/3/2013 10:09:00 AM 1568 (0x0620)
Entering ReleaseSource() for D:\_SMSTaskSequence\Packages\WCD002D2
InstallSoftware 12/3/2013 10:09:00 AM
1568 (0x0620)
reference count 1 for the source D:\_SMSTaskSequence\Packages\WCD002D2 before releasing
InstallSoftware 12/3/2013 10:09:00 AM
1568 (0x0620)
Released the resolved source D:\_SMSTaskSequence\Packages\WCD002D2
InstallSoftware 12/3/2013 10:09:00 AM
1568 (0x0620)
pInstall->Install(sPackageID, sProgramName), HRESULT=80070001 (e:\nts_sccm_release\sms\client\osdeployment\installsoftware\main.cpp,361)
InstallSoftware 12/3/2013 10:09:00 AM
1568 (0x0620)
Install Software failed, hr=0x80070001 InstallSoftware
12/3/2013 10:09:00 AM 1568 (0x0620)
Process completed with exit code 2147942401
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)
Failed to run the action: HP Server Pack for ProLiant 2013.02.
Incorrect function. (Error: 80070001; Source: Windows)
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)
MP server http://MP_server.company.com. Ports 80,443. CRL=false.
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)
Setting authenticator TSManager
12/3/2013 10:09:00 AM 3372 (0x0D2C)
Set authenticator in transport TSManager
12/3/2013 10:09:00 AM 3372 (0x0D2C)
Sending StatusMessage TSManager
12/3/2013 10:09:00 AM 3372 (0x0D2C)
Setting message signatures. TSManager
12/3/2013 10:09:00 AM 3372 (0x0D2C)
Setting the authenticator. TSManager
12/3/2013 10:09:00 AM 3372 (0x0D2C)
CLibSMSMessageWinHttpTransport::Send: URL: MP_server.company.com:80 CCM_POST /ccm_system/request
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)
Request was succesful. TSManager
12/3/2013 10:09:00 AM 3372 (0x0D2C)
Set a global environment variable _SMSTSLastActionRetCode=-2147024895
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)
Set a global environment variable _SMSTSLastActionSucceeded=false
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)
Clear local default environment TSManager
12/3/2013 10:09:00 AM 3372 (0x0D2C)
Let the parent group (System Management Install) decides whether to continue execution
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)
The execution of the group (System Management Install) has failed and the execution has been aborted. An action failed.
Operation aborted (Error: 80004004; Source: Windows)
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)
Failed to run the last action: HP Server Pack for ProLiant 2013.02. Execution of task sequence failed.
Incorrect function. (Error: 80070001; Source: Windows)
TSManager 12/3/2013 10:09:00 AM
3372 (0x0D2C)Hello Guys!
HP ProLiant Support Pack / Service Pack uses different Exit Codes, due to that this software support other operating systems than Windows. Therefore HP has standardized to use other Exit Codes, which Windows Detect as failures.
HPSum Exit Codes:
ExitCode 1 = "Installation Successful"
ExitCode 2 = "Installation Successful, but a reboot is required"
ExitCode 3 = "Installation was canceled, or no components were updated"
EcitCode 9009 = "Installation did not complete. Check the path and make sure that the Installation exists at the specified location"
HP recommends to use following Batch File to workaround this issue for SCCM:
=======================START_BatchFile=============================
:Init
@Echo Off
Cls
:Main
Echo HP Proliant Service Pack Setup
Echo Source : %~dp0
Echo ===============================================================================
Echo Installing the HP Proliant Service Pack Setup
Echo Command: "%~dp0hpsum.exe" /use_latest /target:%COMPUTERNAME% /force /Use_WMI /s
"%~dp0hpsum.exe" /use_latest /target:%COMPUTERNAME% /force /Use_WMI /s
:CheckForErrors
Echo HP Proliant Service Pack Stauts:
If "%errorlevel%"=="0" (
Echo *******************************************************************************
Echo INSTALLATION FAILED!
Echo *******************************************************************************
exit 1
If "%errorlevel%"=="1" (
Echo Installation Successful!
exit 0
If "%errorlevel%"=="2" (
Echo Installation Successful, but a reboot is required.
exit 3010
If "%errorlevel%"=="3" (
Echo Installation was canceled, or no components were updated
exit 0
If "%errorlevel%"=="9009" (
Echo Installation did not complete. Check the path and make sure that the
Echo Installation exists at the specified location:
Echo Path: %~dp0
Exit 1
:End
Echo An unknown status code was returned from the PSP.
Echo This status code is [%errorlevel%]. This will be treated as a success,
Echo but please check the installation to make sure it completedly properly!
Exit 0
=======================STOP_BatchFile=============================
God Luck!
Best Regards Anders Horgen -
Trigger Application successful but with no transfer
Hello,
I am using CRS 5.01
I am sending callers to another application once we close. Once the call is sent to the Trigger Application step. The call is then fowarded successfully but I do not hear the next script.
1. I created the Application and trigger.
2. Associated it to a known good script.
3. Created a string with the name of the application.
4. Created the trigger application step.
5. Did NOT put on synchronous, as it was successful without it but errored when it was turned on.
Was wondering what I am doing wrong!
Thanks.No, that's what we have checked. No error on the IDoc. Check that the goods receipt is posted successfully and can see the goods receipt/material document on the PO History screen of the PO. Everything is fine from a confirmation perspective.
Confirmation status is Approved in SRM.
Regards
SF -
HRMD_A idocs sent and processed, but Org chart doesn't reflect it sometimes
From our HR box, we send HRMD_A idocs to our FI box - We have an intermittent issue where we have a position change & the idoc gets created & sent over.
On the inbound side, the idoc gets posted successfully with Status 53. However, this EE does not appear in the org chart as it does on the HR side.
We have these IDocs set up to process immediately, so it passes to the FI port and is processed all within a few seconds.
We come across this issue once about every 3-4 weeks and I can't seem to get anywhere trying to resolve it.
any ideas?There are two main annoying problems with Flash Builder and swc's:
1. Flash Builder doesn't reflect changes made to swc files
Solution : First of all - keep your swc files inside your project folder, you can also disable global swc cache: change as3api.cpp code,refresh swc in flashBuilder bug!
2. Flash Builder breakes content inside swc files (and also popular problem "TypeError: Error #1034: Type Coercion failed: cannot convert flash.display::MovieClip@1f21adc1 to...")
Solution : locate the project .actionScriptProperties file and set useFlashSDK=”false” : Flash Builder 4.7 – useFlashSDK | In Flagrante Delicto!
In this case you can also download latest Apache Flex SDK to target new Flash player versions: http://flex.apache.org/
Hope this helps!
P.
Maybe you are looking for
-
Photos from hard drive to dropbox
I would like to have a safer set-up with my photos in LR. Have anyone tried to do the following: 1. Open LR and move all of your photos from your hard drive (internal and/or external) to dropbox 2. Now you have all the files in dropbox and the LR cat
-
How to set condition in choose from list based on the combo selection
Dear Members, i have a requirement to filter the item based on the itemgroup. After choosing the itemgroup in the dropdown list i have to filter the item for the particular group in the choose from the list.since i have tried in the combo select
-
MFC database compact - how long to run ?
Our MFC server ran out of space yesterday so we've had to do a compact on the database. I followed the instructions on the knowedlge base, answer ID 691, backed it up to another server (mapped a drive and redirected output to that drive) and now tryi
-
R61 - How to effectively usd 4GB in 32-bit Windows
Hi, Due to limitation on 32-bit Windows, only 3GB will be used. Are any programs (e.g. RAM drive) or devices (used as video memory by intergrated chipset such as Intel G35/G45 or AMD 780G) able to utilize the remaining 1GB that is not occupied by Win
-
WMB54G - Win7 64 - I'm going crazy
Hi Guys, i own an WMB54G for a couple of years now and i got it worked under Win7 x64 but now i had to reinstall my system and i can't get it work. First of all, the WMB is okay because under Vista (Dualboot) everything works fine. - When i install t