Infoset problem

We tried to get Appraisal related data which is part of PCH logical database from tables HRP1000, HRP1001, HRP1045 in an infoset. In the same infoset we have fields for PNP logical database for other PA and OM related data.
The Infoset is not working and it is timing out once it goes into the HRP tables loop. Can we extract data from both logical databases in an Infoset?
Any help is appreciated.

Can you just make do with PNPCE? All OM data related to the employee is already there.
I'm guessing youve done table join for fields in both logical databases?
Edited by: Clueless Noobie on Feb 19, 2008 5:42 AM

Similar Messages

  • Infoset problem: rollup issue

    Hi,
    I have a problem in Infoset.
    Actually i built an infoset based on two infocubes.
    One cube has - Customer, revenue, cost
    Other cube - Customer, name, address
    1st Cube
    Customer     Period/fiscal year      Fiscal year         Revenue    Cost
    A                  01/2008                  2008                   10             5
    A                  02/2008                  2008                   20             2
    B                  02/2008                  2008                   30             5
    2nd cube
    Customer     Name          Address
    A                John            12 street
    B                michael       45 street
    Now im getting value while doing infoset
    A          John           12street         01/2008       2008      10            5    
    B          michael       45 street       02/2008       2008       30           5
    It doesnot consider the line 2 of 1st cube. I want it to rollup and show revenue and cost as 1020 and 52
    How should i do that?
    Regards

    Are you using inner join or left outer join?
    Checkout the below thread if this is of use.
    InfoSet Joins - Left Outer Join problems

  • Modifying  the Ad-hoc Query Infoset : problem with P9105 fields.

    Hi all,
    Am having problem with Infoset of Ad-hoc Query .
    i need to add the Critical role Field Group to ZHR_PA_01 Infoset of Satandard Area.
    for this i have imported that Infotype 9105 and included the following standard fields by drag and drop.
                    1. Role Category
                    2. Role SubCategory
                    3. Global Identifier 
                    4. Personnel Number
    and then Saved and Generated the infoset succesfully.(No syntax errors)
    But
    While testing, using the T-Code:  S_PH0_48000510
    if i select one of these above fields for the report,
    Am getting the message that "Error when generating the report".
    Error Description:The report cannot be generated because the internal description is invalid or incomplete.
    means what may be the problem.?
    if i select other fields its working fine.
    can any body explain me clearly..??
    Regars,
    Kalam A.

    Hi Manoj,
      yes, i have saved the T-code.and generated the Infoset Succesfully.
    and its showing the those additional fields while testing.
    for remaining fields its working fine.
    but am not getting wats problem with the four fields of P9105 infotype.
    could you please suggest me.?
    Regards,
    Kalam A.

  • InfoSet problem with BI 7

    We have a query on an InfoSet in production system (BW 3.0B) that is working fine. The same query on the same InfoSet in development system (BI 7) is not displaying master data attribute values. It does show values only for navigational attributes.
    My team and I have separately verified that the master data exists and active.
    Obviously we don't want to mark the attributes as navigational just so we can display the data in the reports.
    A quick search in OSS did not return any applicable SAP Notes.
    Does anyone know what has changed in BI 7 and how to overcome the issue? Thank you very much for your help.

    Hi SK,
    1. Use transaction RSD1 -> enter the name ZUCESID.
    2. Go to master data/texts tab  check if the "Character is Infoprovider" flag is set or not
    If this flag is not checked, then check the flag and assign a infoarea to it.
    Assign points if helpul
    Regards, Uday

  • BI 7.0 Infoset query open problem: query_tech_name_Fxx is not a valid char.

    Our BASIS transport our BW 3.5 queries to BI 7.0 system.  We can open all queries on the BI 7.0 box without problem except Infoset queries.  The Infoset is composed of two ODSs and when openning it BI 7.0 query designer, can not see any design element in the panes of Rows, Columns, Free Char. and etc., instead the error msg shows (in between two dashed lines below):
    Terminate: query_technical_name_Fxx is not a valid characteristic for InfoProvider [A122(BRAIN)]
    Diagnosis
    Customer enhancement RSR00002 or the implementation of BAdI RSR_OLAB_BADI delivers query_technical_name_Fxx as the characteristic to be calculated. 1. is, however, not a valid key figure for InfoProvider .
    System Response
    The information from query_technical_name_Fxx is ignored.
    Procedure
    Check the exit.
    Procedure for System Administration
    We've checked the enhancement RSR00002 and it's components and find they are all the same as our BW 3.5 system.  query_technical_name_Fxx is Company Code InfoObj. in one ODS and it's one of the key to join these two InfoSets.
    Any idea?
    Thanks

    hi Kevin,
    check if helps following oss note
    Note 983449 - Termin A122 1COLUMN no valid characteristic of infoprovider
    Symptom
    Termination A 122 Brain occurs when you test and generate a query. The system does not recognise the characteristic 1COLUMN.
    Other terms
    Query, condition, COB_PRO
    Reason and Prerequisites
    This problem is caused by a program error.
    Solution
    SAP NetWeaver 2004s BI
               Import Support Package 10 for SAP NetWeaver 2004s BI (BI Patch 10 or SAPKW70010) into your BI system. The Support Package is available once Note 914304 "SAPBINews BI 7.0 Support Package 10", which describes this Support Package in more detail, has been released for customers.
    In urgent cases, you can implement the correction instructions.
    You must first implement Notes 932065, 935140, 948389, 964580 and 969846, which provide information about transaction SNOTE. Otherwise, problems and syntax errors may occur when you deimplement some notes.

  • BI 7.0 Problem while executing query on Infoset containing Infocubes

    Hi All,
    While executing quey on infoset containing infocubes we are getting following error message.
    EError while reading data; navigation is possible
    EError reading the data of InfoProvider A2PPI103
    EError when generating the SQL statement
    E[IBM][CLI Driver][DB2] DSNT408I SQLCODE = -204, ER ROR:  SAPR3.T00001 IS
    I>> Row: 11 Inc: RAISE_READ_ERROR Prog: CL_RSDRV_VPROV_BASE
    any idea what could be the reason ?

    Hi All,
    it's very interesting the question of HariPrasad because from yesterday i have the same problem in  a similar environment:
    @5C\QError@     Error reading the data of InfoProvider ZC1ITS02
    @5C\QError@     Error when generating the SQL statement
    @5C\QError@     [IBM][CLI Driver][DB2] DSNT408I SQLCODE = -204, ERROR:  SAPBWD.T00002 IS AN UNDEFINED NAME  DSNT41 8I SQLSTATE   = 42704 SQLSTA
    May the SQL generator does'nt work well whit cube and DB2 ??
    If i execute the Infoset with the debbugging option i can see the SQL code:
    ...........FROM "/BIC/PZC1CPROD0" "T00001",
    "T00002"
    WHERE................
    the first table is an infoobject, the second one is the "missing" cube...............
    Hari, did you solve the problem in the meantime ??
    Thank's to all, Ray.

  • I am facing a problem in a crystal report which is based on Infoset query

    Hi All,
    I am facing a problem in a crystal report which is based on Infoset query.in the Cost Analysis - Planned vs. Actual Order Costs
    There are two querys like Query: CO_OM_CA_20_Q1 and InfoSet: ZBPBI131_INFO_ODVR. I build infoset query based on sap best practice user guide but problem is not able to find CO_OM_CA_20_Q1
    Best Regards,
    Srinivas

    Hi,
    I would first of all suggest you don't open the same question twice. this looks like a duplicate to this entry:
    Best Practices v3.31 - SAP InfoSet Query connection
    Did you assign the queries and the infosets to an InfoSet user group and you assign the SAP account to it as well ?
    Ingo

  • I am facing a problem in a crystal report which is based on Infoset query.i

    Hi All,
    I am facing a problem in a crystal report which is based on Infoset query.in the Cost Analysis - Planned vs. Actual Order Costs
    There are two querys like Query: CO_OM_CA_20_Q1 and InfoSet: ZBPBI131_INFO_ODVR. I build infoset query based on sap best practice user guide but problem is not able to find CO_OM_CA_20_Q1

    Please re-post if this is still an issue to the Business Objects Integration Kits - SAP Forum or purchase a case and have a dedicated support engineer work with you directly

  • Problem with variable on 0fiscper on a infoset in a report

    hi ,
    I have an infoset  on two ods's , ods1 & ods2. I have used inner join and the join is on field 0fiscper and fiscal variant. Which are  present in both ods.
    In my query i have created a variable on ods1 0fiscper, the same variable appears for ods2 0fiscper also.
    I have two issues mainly
    1. In the variable entry screen when i click  the button for value selection - i am get a lot of values for 0fiscper , even though my both ods have 6 periods only. I have other reports which use the same variable there i don't have a problem.
    2. And after the query is executed when i try to filter on 0fiscper i get the following error
    <b>System error in program CL_RSMD_RS_SPECIAL and form GET_DIME_VALUES-02 (see long text)</b>
    I am assuming the problem are due to the info set.
    Any help is appreciated.

    FYI, when you create a variable on a characteristic (in your case FISCPER), those variables are not query specific. They are known as global variables and hence are avble in all queries were 0FISCPER is used.
    As for the error message...please look into the SAP Note <a href="https://websmp103.sap-ag.de/~form/handler?_APP=01100107900000000342&_EVENT=REDIR&_NNUM=1006369&_NLANG=E">1006369</a>.
    Hope this helps.

  • Problem in select query in QUERY INFOSET

    Hi All
    I have requirement to find the sales text maintained for sales order in mass in production. By using the FM READ_TEXT i can pass the necessary values to get the sales text. We dont want to write a program and then transprot to P01. So what i did in SQ02 i create a infoset and worte code in the infoset. Here i am facing the problem that in the select query where clause what ever  on the selection screen values, for that the query need to fetch the records. But selection screen is dymically selected based on SQVI t-code.
    In select query if i write like this
    SELECT TDOBJECT TDNAME TDID TDSPRAS
           FROM STXH
           INTO TABLE IT_TEXT_DETAIL
           WHERE TDOBJECT     EQ C_KNMT .
    Here i have hardcoded KNMT so it will fetch only that value irrespective of any values on the selection screen. How to get the values based on the selection screen. I debugged the query it automatically generates the code for selection screen which i am not able to pass in the program.
    SAP has generated this code
    select-options SP$00004 for STXH-TDOBJECT.
    select-options SP$00005 for STXH-TDNAME.
    select-options SP$00006 for STXH-TDID.
      If i pass SP$00004 on where clause its giving me error. So how to pass it dynamically. Waiting for experts answer.
    Regards
    Vijay

    Hi Vijay,
    In this case concatenate 'TDOBJECT' 'EQ' C_KNMT INTO V_WHERE (Say) SEPERATED BY SPACE.
    DATA : v_where(90) type c.
    clear v_where.
    CONCATENATE  'TDOBJECT'
                               'EQ'
                               C_KNMT
                               INTO V_WHERE
                               SEPERATED BY SPACE.
    SELECT TDOBJECT TDNAME TDID TDSPRAS
           FROM STXH
           INTO TABLE IT_TEXT_DETAIL
           WHERE (V_WHERE) .
    Try to do this and let me know in case of any.
    Regards,
    SRinivas

  • Problem using SELECT-OPTIONS in an InfoSet with a field of data type UNIT.

    I have created a simple InfoSet that links MARA with MARM. In the 'Selections' section of the InfoSet I have a variable named 'ZMEINH' defined as
    Description: UOM
    Selection Text: UOM
    Format FOR: MARM-MEINH
               EXTRAS: DEFAULT 'PAC' OPTION EQ SIGN I.
    When I ran a query to allow selections on the MEINH field, instead of 'PAC' being the default, there was "***" showing in the UOM selection and if I attempted to execute the query it gave me a message that "Unit *** is not created in languague EN'.  If I overide the "***" and enter 'PAC', I get the list of records that I expect.
    I assume this is because MEINH has a data type of "UNIT".
    How can I do a conversion so I can define a default value 'PAC' for MARM-MEINH in the infoSet that will carry through to any queries I created.
    Thank you very much for any help.
    Richard Salisbury

    Thank you both for you help!
    In our T006 there actually is a PAC and not a PAK. The T006A had as DE-PAK though.
    I had this same type of language problem when trying to match an "order type". German is the "base" language in our system so maybe that means that raw data is stored with the German constant?
    Anyway, I changed it to PAK and it works. When under a time schedule, that is what counts.
    Thank you again for the quick response!
    Richard Salisbury

  • Problem with Update Text fields in Infoset

    Hi experts,
    Here i would like to rephrase the question. Normaly while working with Infosets, when press "update text fields" button, those fields having text is updated. But one of my field is not updated. I need some help from you for that.
    One more question i've that my field is having check table so i would like to know how exactly the text field is updated.
    scenario.
    Customized IT9320 has field prt_pos added. This field is having check table T528B. But i want text field to be attached is IT1000-STEXT.
    How this can be done, because i suspect that just using check table field IT1000-STEXT is not attached to IT9320-prt_pos.
    Please help. I'm really got stuck here.
    Thanks a lot,
    Toral.
    Hi,
    I'm working on customised Infotype. I need to add one new customised field ie Present Position. This field has number as well as text associated with it. There is a check table attached with this field so that text can be displayed alongwith number.
    I need this field in SAP/Adhoc query. But when i go to SQ02 this fields shows only value. Text is disabled for this field. I'm not sure why is it so.
    I looked into other infotype which as one field using same data element, and that field shows both value as well as text. Please help me to rectify this issue for present position field.
    Thanks,
    Toral.
    Edited by: Toral Sheth on Jul 4, 2008 2:01 PM

    You would be much better off with one multi-line form field.
    There are many problems with trying to determine when one is at the end of the display field with text entry.

  • Problem with custom code in infoset query

    Hi,
    I have created a infoset. In the infoset i added a few additional fields and wrote code in the field code for those fields. I saved and generated the infoset. But in the output of the query, i am getting blank values for those additional fields. When i checked the generated program (SE38), the code is not present in the program.
    If anyone has encountered a similar problem and resolved it, please let me know where i am going wrong.
    Thanks.

    Hello,
    After adding the code for additional fields in Infoset, please syntax check and then activate the Infoset. Then the program will be regenerated with your custom code.
    Thanks,
    Venu

  • Problem accessing Infosets using Query with SQL

    Hi,
    I have Lumira desktop version 1.18.0.
    Using the Query with SQL connection, I successfully connected to SAP R/3 6. I was able to view the User Groups under CATALOG_VIEW, but it seems I cannot go beyong this point and select an Infoset. When I click on an Infoset I expect the Query pane to be populated with the SQL statement but nothing happens.
    I attached a screenshot for clarification
    Thanks
    Dany

    Hi Dany,
    A suggestion for you would be to use another client tool & check if the behavior is the same. I suggest that you use Information Design Tool (from BOE 4.1), create a connection to your ERP, then a data foundation on top of that connection and check if the behavior is the same. This way we can isolate if the problem is caused by the client tool or by the backend.
    My 2 cents
    Antoine

  • *Problem in Query Designer using Infoset

    Hi,
    I'm having an Infoset that I'm creating a quey against.
    The query works fine with a few characteristics and keyfigures.
    But sometimes i got the following error messages when adding another characteristics or keyfigure:
    Operand data type varchar is invalid for sum opera tor.Operand data type varchar is invalid for sum o perator.
    Notification Number RSQBW 000
    Error when generating the SQL statement
      Notification Number RSQBW 804
    DBMAN 305
    BRAIN 289
    Can anyone help me, please?
    Thanks,
    Ingmarie Gärdströ

    It sounds as if the Key Figure that you added to your query has been defined underlying RDBMS (e.g. Oracle) for your BW system as an alphanumeric (VARCHAR) and since the data isn't defined as being numeric, it can't sum the data. This might also be caused by an known problem the BW application and there may be an OSS Note, or more than one, that resolves this issue.

Maybe you are looking for

  • Junk Mail won't move to Junk folder after training+switching to automatic

    After training for months, I switched my preferences to automatic and now my existing junk mail doesn't move to the junk folder. Dual 2 GHz PowerPC G5   Mac OS X (10.4.3)  

  • Bitt locker loss a recovery Key

    my respected sir                        i am using window 7 ultimate on my computer i lost my recovery key of Bit locker when i use the password to unlock my driver Show this massage (bit lockernot Response) how i can unlock my Drive. In my drive my

  • What to Do About an Upgrade?

    Okay, here's my dilemma.... I upgraded to my current phone, a Samsung Galaxy Nexus, in January 2013, making it eligible for an upgrade in January 2014.  Since my wife's phone was working fine at the time, I transferred her upgrade to get the phone. 

  • BUG?  ViewObject contains more than one Row with equal Key objects

    JDeveloper 10.1.2.1 build 1913 JClient app aView ----bView --------cView ------------dView BEFORE: cView's detail row set contains two dViewRowImpl rows, as expected: row 0: key = 100 row 1: key = 101 ACTION: An attribute, X, in dView is modified by

  • How to manually insert a jumper multisim

    hi i want to transfer my circuit to ultiboard but i need a jumper how do i add it on multisim my version does not support automatic insertion.