LabVIEW TestStand Runtime Server

I am using TS3.5 and LV8.2 and my LabVIEW Adapter is TestStand LabVIEW Runtime Server. When I launch my TestStand/TestExec application the TSLVRTS automatically launches too and everything runs fine, the problem is that when I close the app the TSLVRTS stays open and it is supposed to close automatically.
This is the content of the TestStandLVRTS.ini:
[TestStandLVRTS]
viSearchPath=<topvi>:\*
[Server Options]
Hide=TRUE
[TestStandLVRTS]
hideRootWindow=TRUE
Does anyone has an idea of what could be causing this? or where to get a full list of the flags that can be set in the TestStandLVRTS.ini file?
I have exactly the same flags in my TestStandLVRTS.ini file for LV7.0 and TS3.0 and everything works fine.
Thank you for your help

In TestStand 3.0 and prior, the LabVIEW Runtime Server shut down when the Adapter was unloaded.  However, this behavior was intentionally changed in TestStand 3.1.  When multiple processes were using the LabVIEW Runtime Server, this caused problems when one of the processes exited.  The Runtime Server was closed, even though the other process may still be using this server.  To correct this undesirable behavior, we do not try to shut down the Runtime Server.  The LabVIEW Runtime Server is left open intentionally.  You will not be able to change any flags to have it shut down since the code is inside the LabVIEW Adapter for TestStand.
Allen P.
NI

Similar Messages

  • Can't create Labview 6.02 runtime server.

    I tried to use the Labview source code for the Runtime Server to build a LV 6.02 Runtime Server that I can use in TestStand 2.0 with a Visual Basic Operator Interface.
    Right now, I cannot run an example TestStand sequence with the example Visual Basic Operator Interface...I get error 18002.

    This error means the VI that you are trying to call is not executable. There are usually 2 reasons for this.
    1) The most likely cause is that you have not assembled your VIs for distribution. Whenever you try to run a VI on a machine using the the LV run-time engine, you must distribute other VIs on which your VI is dependent. TS ships with a tool that will search you sequences, find all called VIs and then gather up all the necessary support files. You then must change your TS search directories to reference these compiled files so that your sequences use them over the development VIs. These are the files that you must distribute to your target machine. I STRONGLY recommend that you test your assembled VIs and your run-time server on your development machine befo
    re distributing. If it doesn't work on the development machine it is a waste of time to distribute. Please read the NIDZ document "Overview of Distributing TestStand when your Sequences use the LabVIEW Standard Prototype Adapter".
    2) The other cause is that you VI is truely broken (e.g. bad wires, bad subVI, etc). Usually you would have detected this problem when running the VI on your development machine.
    Nemo

  • LabVIew Runtime server

    The first version of TS I used was 3.1about 1+ years ago and never heard about the LabVIEW Runtime Server, I always used either the LV RTE or the Dev System as my LV adapters. Now, I'm trying to move some old stuff that is in TS3.0 LV7.0 to TS3.5 LV8.2 and I am having problems creating the LVRTS executable (windows problems). Does anybody know where can I find documentation on this? Everybody seems to have forgotten why are we even using it...
    Thank you.

    Hi,
    The Runtime Server was provided, so that you could run the LabVIEW code modules, when deployed on a system with no developement system. The Server could either be the LVRTS or the Labview Operator Interface.
    What windows problems are you having?
    One thing to remember, make sure all you VIs are at the same versions that includes your code modules and the various TS assoicated VI's.
    You dont really have to do much with the RTS, just mass compile all the relevant VI's. Load the bld file and rebuild.
    Regards
    Ray Farmer
    Regards
    Ray Farmer

  • Test Engineer (LabVIEW/TestStand) Required - Detroit, Novi - Michigan

    Hi all,
    Harman International Inc., is looking for a Test Engineer to add to our Team.
    Job Location: Novi, MI
    Job Type: Full Time / Permanent
    Job Location: Novi, Michigan
    Job Description,
    Knowledge in electronic design for testability requirement.
    Knowledge in LabView/TestStand/Process Model test development platform.
    Able to develop testing tools (including but not limited to communication protocol tool, driver interface either for specific product, device and/or instrument etc) in LabView/TestStand environment via VB, DotNet or other interfaces as appropriate.
    Able to develop, debug and implement manufacturing test SW package based on test spec & test requirement for optimized production test quality control and efficiency.
    Knowledge of measurement statistical analysis for production support.
    Experience: 3 - 10 years.
    Please send me Private Message (PM) for the contact details to send your resumes.
    Note that candidates must be authorized to work in US (H1B VISA)
    Thanks
    Vijay

    cross-posted on https://lavag.org/topic/18822-test-engineer-labviewteststand/#entry113145
    Jim
    You're entirely bonkers. But I'll tell you a secret. All the best people are. ~ Alice

  • LabVIEW / TestStand Opening in Rockleigh NJ

    Crestron is looking for a talented individual to fill the position of Test Engineer III at our corporate headquarters in Rockleigh NJ (07647). This position will be part of our Test Framework Development team, and will develop advanced production test platforms using National Instruments’ LabVIEW, TestStand and Visual Studio C#. This role will focus heavily on creating the underlying structure for Crestron’s automated test platforms and on designing modular test systems that can be adapted to a wide variety of applications and products. The systems that you produce will be used by downstream engineering teams to develop final acceptance tests for Crestron’s products.
    Key responsibilities:
    Create LabVIEW VIs to interface with a variety of test instrumentation, and with Crestron equipment and software
    Use MS Visual Studio to create C# code that will exercise Crestron hardware. We will provide extensive training on how to work with Crestron systems 
    Support TestStand automation of production tests
    Assist in the selection and adoption of test instrumentation
    Work closely with product designers and firmware developers during the new product development process
    Work closely with other test engineers during the test development, integration and implementation of production tests
    Other duties as assigned
    Crestron is looking for a highly motivated, results-driven individual with exceptionally strong computer programming and technical skills. A successful candidate will have extreme proficiency with LabVIEW, TestStand and C#, Java or C++. General electrical engineering knowledge and experience with product testing in a manufacturing environment is essential.
    Required Skills and Experience:
    Bachelor’s of Science degree in Electrical Engineering, Computer Engineering, or Computer Science; Masters preferred
    Extremely strong proficiency with NI LabVIEW, NI TestStand and C#, Java or C++. This position will rely heavily on these skills and we will focus on them during the interview
    6 - 10 years of engineering experience with at least 4 years in a test or software engineering related role
    Comprehensive understanding of product test methodologies and techniques
    Superior written and oral communication skills; the ability to work closely with a diverse group of individuals
    A desire to be an essential part of a fast paced, innovative engineering team 
    A passion for quality and a drive for excellence
    https://www2.apply2jobs.com/crestron/ProfExt/index.cfm?fuseaction=mExternal.showJob&RID=2728
    If your interested and able to work in New Jersey USA without requiring sponsorship, etc please either apply through the link above or send me PM with your resume.
    Regards,
    Shaun

    Hi Enquiry,
    The reason for giving personal mail id is: "it is convenient to access
    personal mail id than official id.. I have no intent to hijack your
    cv 
    If you are interested, then you may send your CV @
    [email protected]  . You may ask why not HR mail id ... reason is
    obvious I want to get referral money: smileywink: 
    Regards,
    Naresh.K
    Naresh
    Software Engineer

  • Is it possible to connect labview with opc server without using NI dsc Module ?

    Hellow sir,
    I want to get data over labview using OPC server and i am not using any dsc module vi (Alams, print, GUI, security).I am using share variable to get data from OPC server to labview. Now i want to deploy that application to third party computer. (where there is no NI software is installed)
    i am using labview 8.6 and 2009.
    Many ? like....
    1) what is the procedure to install that application in third party computer.
    2) Do i need to use my dsc run time licence..?
    waiting for your valuable feed back.
    Thank you.
    CLAD
    Labiew programmer

    Hi, When you connect to NI OPC Server by creating New I/O Server > OPC Client. You will see all registered OPC Servers running on local machine or remote machine. I used KepServerEx from Kepware and LSIS OPC Server from LG with no problems. Just make sure that the OPC server is running.
    Hope it helps
    Waleed El-Badry MSc.,MCPD, ISTQB Certified Tester
    Assistant Lecturer
    Mechatronics Department
    Faculty of Engineering
    Misr University for Science & Technology
    Attachments:
    LG.png ‏57 KB

  • LabVIEW/TestStand/PXI Engineering Architect Role in fast growing Semiconductor Services Company

    A reputed Semiconductor Services company is on the cusp of major growth due to recent Brand Recognition and happy customers. The company is looking for a capable, motivated senior engineer or developer who wants to take the next step toward technical/architecture leadership, team leadership and opportunities to make lasting impressions on customers in order to grow the business and themselves. Some questions to ask yourself before you apply:
    a) Do you have 2+ years of experience in LabVIEW/TestStand/PXI with a strong foundation in Electrical/Electronics/Communications/Computer Engineering
    b) Do you feel that your technical skills in the LabVIEW/TesStand/PXI space have evolved to the level that you can punch above your weight compared to the number of years of experience. We are looking for go-getters who may be 2-3 years experience but make a lasting impression on any customers and come across as 4-5 years of experience because of your innate smartness, command of engineering/architectural concepts, communication skills and can-do attitude
    c) Are you driven by a sense of integrity, respect to your colleagues and a strong team spirit
    d) Do you believe that every meeting and deliverable to a customer is a vehicle for company and personal growth?
    e) Do you enter every project and opportunity with a view to ensuring customer delight and loyalty?
    f) Are you fearless about entering new allied technologies such as LabVIEW FPGA/Xilinx//Altera based FPGA/ Microcontroller programming and system design
    If the answer to these questions is yes, please email [email protected] with your most updated resume and prepare to embark on a career that will fuel your  job satisfaction and growth in the years to come. A strong technical background in the areas mentioned is essential and will be tested.
    Company Information:
    Soliton Technologies Inc. is a value-driven Engineering Services company with over 15 years of experience and steady services growth in the Semiconductor, Automotive, Biomedical and Test and Measurement industries. (www.solitontech.com). Soliton's services range from LabVIEW and TestStand based Validation Automation (often PXI based), GUI Frameworks, Embedded Development Services on NI Embedded targets as well as Microcontrollers, High Speed FPGA Design, Enterprise Software Development on Multiple programming platforms ( C, C++, C#, .NET, Python, Java, HTML5 etc) and Vision Based Test Systems. The company has a strong Semiconductor focus in the past decade with multiple Fortune 500 customers with steady growth and a track record of customer retention.
    Compensation: Not a constraint for the right candidate.

    Hi,
    Kindly arrange an interview process.
    I have attached my resume
    Regards,
    Bharath Kumar

  • LabView/TestStand Developers wanted in Dallas with Systems Integrator

    VI Technology is currently looking for LabView/ TestStand developers for the Dallas Area. www.vi-technolgy.com  Please email [email protected] or call or dallas office at 972-233-1950 ext 201. 

    Thank you for your replies. We have found a suitable candidate.

  • Oracle/wh/runtime/server/Util does not exist - while creating runtime repos

    While running OWB Runtime Assistant, at about 60% completed, getting an error.
    Here is the last few lines from the log file:
    oracle.wh.util.DebugUtility: [processSPAWN]: wholeLine =..\..\..\jdk\jre\bin\javaw -classpath ../../lib/int/rtpplatform.jar;../../lib/int/rtpcommon.jar;../../../jdbc/lib/ojdbc14.jar;../../../lib/xmlparserv2.jar;../../../sqlj/lib/runtime12.jar;../../../jdk/jre/lib/rt.jar oracle.wh.runtime.platform.service.install.ServiceInstaller %host %port %serviceName %user %password
    Mon Feb 06 11:58:00 CST 2006
    oracle.wh.util.DebugUtility: after executing the output
    Mon Feb 06 11:58:00 CST 2006
    oracle.wh.util.DebugUtility: Runtime Platform Property Load Beginning...
    Mon Feb 06 11:58:00 CST 2006
    oracle.wh.util.DebugUtility: java.sql.SQLException: ORA-29540: class oracle/wh/runtime/server/Util does not exist
    Mon Feb 06 11:58:00 CST 2006
    oracle.wh.util.DebugUtility: [processSPAWN]: A spawned program error. Exception = java.lang.Exception: Error : java.sql.SQLException: ORA-29540: class oracle/wh/runtime/server/Util does not exist
    Mon Feb 06 11:58:00 CST 2006
    oracle.wh.util.DebugUtility: [processSPAWN]: Get the error, stop processing...
    Mon Feb 06 11:59:47 CST 2006
    oracle.wh.util.DebugUtility: Assistant operation is unsuccessful ...
    =========================================
    The database version is 9.2.0.4 on XP
    OWB version is 10.1.0.2 on the same XP host.
    I'd prefer NOT to change (upgrade or degrade) the versions of db and owb, as the same version combination works just fine in production, and I'm trying to create the same environment on my local PC.
    Thanks for your help.
    vr

    I did that and my output is all good:
    All PL/SQL packages and functions are valid
    Platform properties have been loaded correctly
    Platform location has been seeded correctly
    NLS messages have been loaded correctly
    The platform service is available
    PL/SQL procedure successfully completed.

  • Labview and ole-server

    Hi,
    I need information about the activation of an "OLE server" via Labview.
    This server is activated without any problems by using the "CreateObject ("servername")" command within the Excel and Visual Basic environment and all methods are available. I tried an automation-refnum to find the server in the Labview Library - without any success.
    How might I realise this Labview Problem?
    Thanks
    Alex

    Hi BSS
    Your ActiveX device must be registerd in windows.
    Than you can create for example an ActiveX Container.
    Open the context menu by right-clicking and  select "Insert ActiveX Object ..."
    Is your ActiveX device not listed there. Choose "Create Object from File"
    instead of "Create Control" and directly select it
    I give you some attachements to visual the actions.
    Lars
    Attachments:
    ActiveX general programming example.PNG ‏3 KB
    ActiveX Container.JPG ‏82 KB
    Create Object From File.JPG ‏53 KB

  • LabView/TestStand Developer - Herndon, VA

    Senior Production Test Engineer
    Job Description:
    ABOUT THE COMPANY iDirect is dedicated to providing next generation solutions for broadband IP networking via satellite networks. For more than 20 years, the VT iDirect organization has focused on meeting the economic and technology challenges across the satellite industry. Today, the product portfolio, branded under the name iDirect, sets new standards in performance and efficiency, making it possible to deliver voice, video and data connectivity anywhere in the world. As the leading innovators in the satellite communications industry, our diverse and talented team of Internet, satellite and telecommunications professionals continues to break new ground and create significant opportunities for network operators, for service providers and resellers, and for corporate networking professionals. If you are ready for the challenges, responsibilities, and rewards that come with working in a high-energy, fast-paced environment, then this is the job for you!
    ABOUT THE POSITION
    We are looking for a true leader in the area of production test development and implementation to significantly upgrade our capabilities and sophistication in an outsourced manufacturing environment. This is a unique opportunity to develop, implement and lead the vision for production test engineering. The Senior Production Test Engineer will be in integral part of the global manufacturing operations team and will interact with the Software and Design test functions. This is a great opportunity to join a growing company in a rapidly developing industry.
    RESPONSIBILITIES:
    Participate in all aspects of product testing within the manufacturing environment.
    Develop, debug and maintain LabView/TestStand code to support production test.
    Partner with Manufacturing Engineering, Quality and Reliability teams to monitor, measure and improve production yields. Develop and optimize the debugging approach incorporating a closed loop corrective action process for root cause identification and correction.
    Identify test process cost savings opportunities and work with other Supply Chain teams to identify and realize regular efficiency improvements and cost reductions.
    Lead projects to improve existing test systems and solve any issues that prevent delivery of professional testing capabilities.
    REQUIRED EXPERIENCE:
    The ideal candidate will come from a communications electronics environment with emphasis in wireless communication, and have a thorough understanding of current test strategies and approaches. In addition, the candidate should have the ability to develop and articulate a clear vision for effective and cost efficient production testing in outsourced manufacturing.
    BS in Engineering required. BSEE preferred, BSEET, computer science/engineering or equivalent experience will be considered.
    10+ years in test engineering or related areas in complex electronics manufacturing environment.
    5+ years of experience working at or with a Contract Manufacturer.
    Experience with LabView/TestStand, Boundary Scan, BIST, POST.
    Strong technical documentation skills including test requirements and test plan development.
    Solid understanding of software design and debug.
    DESIRED EXPERIENCE:
    Experience using databases such as SQL.
    Experience with a variety of programmable instruments; such as Spectrum Analyzers, power dividers, signal generators, logic analyzers, etc.
    Significant RF experience and wireless communications strongly preferred.
    Knowledge of application of test methods (ICT, AOI, and RF communications) desirable.
    Experience with National Instruments hardware a plus.
    Experience programming and interfacing ATE's in VB, C, C++, LabView, shell scripts, Perl, programming language skills for measurement, data acquisition and instrumentation control a plus.
    Equal Opportunity Employer M/F/D/V

    Hi,
    Kindly arrange an interview process.
    I have attached my resume
    Regards,
    Bharath Kumar

  • Does the LabVIEW TestStand UI button control support multi-line captions?

    I would like the caption of a LabVIEW TestStand UI button control to wrap onto two lines (multi-line) instead of being confined to a single line.  For example, instead of the caption looking like:
    Loop On Selected Steps...
    I would like it to appear like this:
    Loop On Selected
            Steps...
    I have plenty of vertical space on my TestStand operator interface but my horizontal space is limited, so it would be preferrable to grow buttons vertically instead of horizontally.

    Upon further investigation, it looks like this is a bug (or a "feature change") in TestStand 4.0.  The TestStand 3.5 UI button control automatically placed text on succesive lines if the width of the button decreased below the size required to accomodate all of the caption text on a single line.  However, this is no longer the case in TestStand 4.0.  TestStand 4.0 does not place text on successive lines when the button size decreases below the threshold.  I cannot figure out any way to place button captions on multiple lines using the 4.0 UI button control, including setting the caption programmatically with a carriage return inserted between successive text lines.

  • Hi..I really don't understand how can labview can be a server, can you explain and give me some examples with steps on how to make the labview as a server? Please......

    nn
    Solved!
    Go to Solution.

    erm ok i will explain...
    actually..i know that labview can be a client or server. when the labview be a client, it can access other enable activeX application such as excel or word. i manage to do that a little such as to open excel file and save it at another location by using activeX functions or using the report generation toolkit. yes, i already know and understand the flow or concept of how the labview can be a client. But by using others activeX application especially excel, how can we make the labview be a server? i just need a very easy example and few steps for me to understand how can labview be a server or how excel can control the labview properties?
    really desperate to increase new knowledge.....:-)
    thank you very much for helping me....

  • LabView 11 Runtime

    Does anyone know why a program that is designed in LabView 2011, won't work on LabView 2011 Runtime on another computer.  I have tested the executable on the computer that the VI was built on, and it does work.  However, it will not change cases when it is run on a Windows 7 and a Windows XP computer running the runtime or regular LabView 2011. The LabView is version 11.0 on both computers as well.  Attached is the VI. Thanks for your help!
    Solved!
    Go to Solution.
    Attachments:
    ConditionalLoopV7withoutDAQ.vi ‏10 KB

    String comparisons can get weird.  If you accidentally add some white space or start a new line that you can't see, then the comparison will be way off.  Instead of using a string, you might want to use an Enum instead.  This will make sure you have very defined inputs and the user can't screw it up nearly as easily.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • HCL America Needs: ATE, Labview/Teststand Engineer: Lake Forest, CA

    Domain: RF/Communication/SATCOM (Aerospace industry)
    Required Skills:
    - Labview
    - Teststand
    - SQL
    - MS Access
    - RF / Antenna knowledge
    Forwared responses to: jc[dot]hcltech[at]gmail[dot]com.
     

    Dear Sir/ Madam,
    I am writing in response to your job notification for Embedded Testing.
    I am a B.E ECE with an aggregate of 7.73% marks.
    - I have good knowledge of programming languages like C, C++, Embedded C,Assembly and Basics of LABVIEW.
    - I’m compatible on working various operating systems like Linux, windows, etc.
    - I have also done 6 months internship from Electro System Associates(ESA) Bangalore.
    Also I have an Experience in the Field of Testing and Measuring Instruments.
    I am from Electronics background .Please provide me an opportunity .
    Some of my personal qualities which you may find useful for this role are:
    - Ability to learn quickly coupled with innovative ideas for problem solving
    - Ability to work in a team with strong communication skills
    - Hardworking and sincere towards work with an ability to take directions
    Please find my detailed CV for your consideration. If you need any more details, please let me know.
    Thanking you for your time and looking forward to hear from you.
    Sincerely
    Gopinath.s
    Ph:9535569115

Maybe you are looking for

  • SSRS Subscription Misrun

    Hi, I have a SSRS Report with a subscription scheduled to run quarterly Jan, Apr, Jul, Oct on the 1st of each month.  The report ran this past Feb. 1st.  I'm unsure why? Can this be fixed? Thank you in advance.

  • Multi-Language content

    Hi, In my content area, i have a URL Item. This item calls a procedure in the database (ex. Alain.Show_Plants.Main?Pant_Id=1). In my procedure, I call the function wwctx_api.get_nls_language to get the language of the current user. But the function a

  • Save tabcontrol content in variant on dynpro

    Hi all, I've the following problem : I'm using a dynpro instead a selection screen. I had to do this because I'm using a Tabcontrol and we cannot use this element on an standard selection screen. I would like to have the possibility to fill the field

  • Database (catalog) for images stored on external devices

    I have lots and lots of images spread across various internal, external drives, cd's, dvd's. My question is does the new LR keep tabs of exactly where my image files are? I am considering purchasing iMatch because it will keep a running database and

  • Decision between multiple alternatives