Labview2011 SIT Connection Manager service

Good day, I am developing an application where I have to communicate com matlab simulink. I have reviewed several bibliographies and material .... in which I refer to SIT Connection Manager service, which I find in my version of Labview (2011) and matlab2011a
thank very much

Have fun.
Alex Thomas, University of Manchester School of EEE LabVIEW Ambassador (CLAD)

Similar Messages

  • How to specify finite simulation stop time in VI generated using SIT connection manager

    Hello,
    I have a SIMULINK model which I want to run on a desktop ETS. I'm following this procedure:
    1. Convert the SIMULINK model in a .DLL using RTW build in Matlab. The target of this build is nidll.tlc.
    2. Create a host VI with required indicators and map the parameters using SIT connection manager.
    3. Configure the DAQ (and then SIT connection manager generated the driver and IO files for me.)
    4. Using LV project, run the driver on the desktop ETS and host VI on the host machine.
    The code is working fine, without any error.
    My question is this: Since in the driver VI, the simulation time is set to -1, which implies "continuous", the simulation goes on until I hit the stop button on the host VI.
    I tried changing this default value to some other value. The simulation then does run for the defined amount of time but then I'm getting error 2206.
    What is an appropriate way to stop the simulation on the RT target?
    Thanks
    Gayatri
    PS: I'm using LV 8.5, LVRT 8.5, SIT 4.0, Matlab @2007a.

    The VI in the Driver VI called SIT Initialize Model.vi has an input called time step (sec) (-1: use model time step) which does what you want it to. It doesn't actually affect the time step of the solver used in the built model DLL, just the rate at which the main base rate loop actually runs in real time. In fact, base rate loop period would be a better name for this control. If you set it, you won't alter your model, but you will be able to adjust the rate of the base rate loop.
    Simply create a control from this input terminal on your driver VI and fill in an appropriate period in seconds. Make sure to set this value as default in the control so that the Driver VI remembers it.
    You will have to take into account that your model will still think it's running at the time step it was compiled at. So your model simulation time and the actual wall clock time won't match up.
    Jarrod S.
    National Instruments

  • HP Connection manager service not installed. Application will exit

    I'm actually having a number of problems with this laptop, but I figured I'd start with this one. I get the message "HP connection manager service not installed. Application will exit.
    As strange as this may seem, when I get this message,  I also cannot open any of the folders on my desktop. I don't know if the problems are related or not.
    Any help is appreicated !
    If this helps its model number is A5F92AV

    Hi @krazykat_randi ,
    Welcome to the HP Forums!
    It is a superb place to find answers and suggestions!
    For you to have the best experience in the HP forum I would like to direct your attention to the HP Forums Guide Learn How to Post and More
    I grasp that you are having multiple issues with your notebook, one of which is when you try to open the connection manager you get the message "HP connection manager service not installed. Application will exit.".  You also can not open folders on your desktop.
    Have you checked for viruses or malware?  MS Malicious Software Removal Tool.
    This is not a recommendation but many people have used Malwarebytes with success also.
    Have you tried running MS Fix It  to aid with overcoming issues?
    Have you tried doing a restore  back to when it was working properly?
    If you still have issues I suggest you do a recovery back to factory.
    HP PCs - Performing an HP system recovery (Windows 7)
    If you have not yet done a backup you will have an opportunity during the recovery to do one.
    HP PCs - Restoring Files that were Backed Up Using HP Recovery Manager (Windows 7)
    Hope this helps!
    Sparkles1
    I work on behalf of HP
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos, Thumbs Up" on the bottom right to say “Thanks” for helping!

  • Mapping to Variables Using SIT Connection Manager

    Hello,
    I have a quick question regarding the SIT Connection manager and mappings.  I was wondering if it is possible to map to variables, using the SIT Connection Manager Wizard, that I can make in the Project Window and drop into my block diagram.  I have the SIT system buried under another VI and it is a hassle to keep having to connect the variables up to their values.  I would like to just be able to map directly to them.  If this is or is not a possibility please let me know.  Thank you.
    Michael B
    LabVIEW 8.5
    SIT 4.0
    Message Edited by Michael B on 11-30-2007 12:52 PM

    Hey Michael,
    Thank you for contacting National Instruments.  I am not sure if I completely understand your question.  Would it be possible for you to walk me through the process you are currently going through to set up these mappings?
    Also, I wanted to clarify what you meant by connecting to variables.  I know you can use the manager to map to indicators and controls, but I am not sure if this is what you are trying to accomplish.
    I look forward to hearing back from you.
    Regards,
    Kevin H
    National Instruments
    WSN/Wireless DAQ Product Support Engineer

  • Using SIT connection manager with large simulink models is extremely slow

    Hello,
    I'm trying to use a large simulink model in LabVIEW but once the DLL is correctly generated and the SIT connection manager is invoked to explore the model sinks, sources and parameters, it takes hours to generate the model connections tree. Afterwards, when the connections tree is completed, it is impossible to handle it because every operation performed takes a lot of time and memory (i.e. to expand a block to see which parameters are inside).
    The version of SIT I'm using is 2.0.3 with LabVIEW 7.1.
    Is there anybody experienced with large simulink models and SIT?
    Thanks and regards.
    Ignacio Sánchez Peral
    SENER Ingeniería y Sistemas S.A.
    Control Systems Section
    Aerospace Division
    C/ Severo Ochoa, 4 (PTM).
    28760 Tres Cantos (Madrid) Spain.
    [email protected]
    Tel + 34 91 807 74 34
    Fax + 34 91 807 72 08
    http://www.sener.es

    The VI in the Driver VI called SIT Initialize Model.vi has an input called time step (sec) (-1: use model time step) which does what you want it to. It doesn't actually affect the time step of the solver used in the built model DLL, just the rate at which the main base rate loop actually runs in real time. In fact, base rate loop period would be a better name for this control. If you set it, you won't alter your model, but you will be able to adjust the rate of the base rate loop.
    Simply create a control from this input terminal on your driver VI and fill in an appropriate period in seconds. Make sure to set this value as default in the control so that the Driver VI remembers it.
    You will have to take into account that your model will still think it's running at the time step it was compiled at. So your model simulation time and the actual wall clock time won't match up.
    Jarrod S.
    National Instruments

  • SIT Connection Manager

    Hi all,
    I have installed the Simulation Interface Toolkit and I have read the SIT manual. However, when I want to do the example which appears, there is a problem. This is, in simulink there isn`t any problem but in Labview doesn`t appear the SIT Connection Manager on the front panel menu bar, Tools»SIT Connection Manager and I don´t know why.
    If someone could help me, I would be grateful.
    Thank you.

    Do you have multiple versions of LabVIEW installed on your computer?  If so, you may have installed SIT to another LabVIEW folder.  Go to your LabVIEW\project folder and see if sitwiz.llb is there.  If not, then SIT did not get installed to this version of LabVIEW.  Check other LabVIEW folders on your hard drive and see if it got installed there instead.  If so, then you can uninstall SIT, then reinstall and make sure the correct version of LabVIEW is selected when going through the installer wizard.
    Good luck,
    -D
    Darren Nattinger, CLA
    LabVIEW Artisan and Nugget Penman

  • Site Connection Manager

    i am new bie in Content server , just starterd learning the ucm and Site Studio 10gR4....
    I want to practice 10gR4 , creating sites , i found 10gR4 sample videos viewlets that are helpfull in learing ,
    but i am unable to make connection of 10gR4 with my UCM server
    please guide

    able to resolve the issue
    was typing wrong url.
    thnx

  • HP CONNECTION MANAGER

    Received the following error message - HP connection manager service has stopped responding.  Please exit and restart the application''
    A fatal error occurred, check the HP connection manager in event viewer for  more details
    Retreiving the COM class factory for component with CLSID (24DB46C8-C842-4E91-9AC4-8A9525A551D) FAILED DUE TO THE FOLLOWNG ERROR:  80070422

    Hi
    Request you to try this step and see if this fixes your issue.
    Start -> Control Panel-> Program and Features-> Select HP Connection Manager and select Repair.
    Let us know how it goes!
    "I work for HP."
    ****Click the (purple thumbs up icon in the lower right corner of a post) to say thanks****
    ****Please mark Accept As Solution if it solves your problem****
    Regards
    Manjunath

  • Can't connect to Configuration Manager Service manager

    So after a failed upgrade to R2, I've had to restore the database as the R2 upgrade corrupted the DB.
    I am now working though the minefield of component errors. However I can't connect to the configuration manager service manager, I get this error:
    Error communicating with the specified Configuration Manager Site Server
    So I have done a site reset and I still have the same issue.
    I have tried several accounts, all with full permissions on the site server and in configuration manager.  I'm stumped now.
    Anyone experienced this before and found a solution?

    Hi,
    Any useful information in your ConfigMgrSetup.log and windows event log?
    Best Regards,
    Joyce Li
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • How can I find out the server port for a secured FTP site and creating a FTP Connection Manager

    I have to create a FTP Task to go out and get the files that our 3rd party vendor will be dropping on a secured FTP site. I have all the credentials to access that Secured FTP Site and have successfully done so through FileZilla.
    Now I need to set-up a FTP Task to go out and get their files and in so doing create a FTP Connection Manager. Is there any way I can determine the
    Server Port number from the Secured FTP site? I let it default to 21 and tried the Test Connect and it failed.
    Thanks for your review and am hopeful for a reply.

    Hi ITBobbyP,
    SSIS has a built in FTP task, while this only works for the FTP protocol, it doesn’t support SFTP. But there are some free clients like WinSCP and
    SSIS SFTP Task Control Flow Component
    available in the CodePlex which can invoked from SSIS.
    References:
    SSIS SFTP Task Control Flow Component approach
    WinSCP approach
    Thanks,
    Katherine Xiong
    Katherine Xiong
    TechNet Community Support

  • Request management service issue with SSL Sites

    Hi guys,
    I've configured up the request management service, but after start the service on our wfe servers (even before to configure specific web applications),  our ssl sites begin to fail and the event viewer start to alert several errors, by the other hand,
    sites over 80 port with no SSL works as expected.
    I've found some similiar scenarios without a happy ending. Below you can find some of the main errors in event viewer and ULS Logs. In
    this post  solved a very similar issue using ssl host headers with a unique ip but we are using fqdn certificates so it is not an option for us.
    I've already checked the
    good posts from Spencer Harbar and He says that is good idea to use host named site collection, but this is not an option for me because we need to use Self Service Creation and mixed authetnication, besides, None of the Technet literature that i've reviewed
    says  something about don't support path based site collection.
    So far, the only way to avoid this errors is not using the service(discouraging finding), These are some errors we got on Event viewer and logs:
    Machine 'MACHINENAME (AppPool(_LM_W3SVC_515444293_ROOT))' failed ping validation and has been unavailable since '3/28/2014 3:55:48 PM'.  (Just starting the service Event viewer begis to have a bunch of this errors)
    03/28/2014 13:34:01.96 w3wp.exe (0x1184)
    0x154C SharePoint Foundation
    Request Management ai2q3
    High Reached maximum number of failed machines based on ping results for this routing group
    53c2819c-8216-20f3-68c0-c0a3e55c92d5
    03/28/2014 13:34:01.96 w3wp.exe (0x1184)
    0x154C SharePoint Foundation
    Request Management ai2q4
    Medium Unavailable machines based on ping results: MACHINENAME
    53c2819c-8216-20f3-68c0-c0a3e55c92d5
    03/28/2014 13:34:01.97 w3wp.exe (0x1184)
    0x1C2C SharePoint Foundation
    Request Management adc7u
    Medium Mapping URI from 'https://HOSTNAME:443/Style Library/somos-sura-css/inicio/inicio.css' to 'https://MACHINENAME/Style%20Library/somos-sura-css/inicio/inicio.css'
    53c2819c-8217-20f3-68c0-cb2f392c388b
    Seems like it tries to find a site with the machine name, not the host name registered in the Alter access mappings (like portal.acme.com) .
    I would appreciate some feedback about this. Another posts with similar issues:
    http://amolmeshe.blogspot.com/2013/05/sharepoint-2013-request-management.html 
    http://www.akspug.org/Blog/Post/4/Request-Management-and-Error-8316 
    Regards,

    Hi,
    According to your post, my understanding is that you had an issue about the Request management service with SSL sites.
    It’s a known issue that the request management service could not work with the SSL site.
    We had already reported the issue to the product team, as a workaround, if you want to use the request management service, you can change the https site back to http.
    What’s more, the SharePoint 2013 SP1 has been relased, you can install it to check whether it works.
    http://support.microsoft.com/kb/2817429/en-us
    Thanks & Regards,
    Jason
    Jason Guo
    TechNet Community Support

  • TS1424 Message saying...Connection Manager invoke failed to find service connection URL why?

    When I go to sign in it iTunes a message comes up stating:  Connection Manager::invoke::Failed to find service connection url.  Does anyone know what this means and how to fix this issue?

    Check over on the right side of the thread here under More Like This. Look for one that has a green checkmark which means it is answered. I have read of this however, I do not know how to solve it. It seems as though it is one particular carrier this happens to.

  • TS1424 Tried to use my apple id to update some apps and got"Connection Manager::invoke:: Failed to find service connection url"  After this occured a few times I reset the id password, and this was confirmed by email.  It still fails with same message.  I

    Tried to use my apple id to update some apps and got"Connection Manager::invoke:: Failed to find service connection url"  After this occured a few times I reset the id password, and this was confirmed by email.  It still fails with same message.  Ideas?

    Hi, you have to logout from your iTunes account and reconnect it:
    Settings / iTunes & App Stores / ...
    https://mobilfunkexperten.de/news/13450/sporadische-probleme-im-itunes-und-app-s tore
    Hope this helps... :-)

  • HT1527 Whenever I try to redeem a card or access my account I get a message "connection manager invoke failed to find service connection url".  I reset my password, logged out and tried logging back in, same message.  How do I solve this issue?

    Whenever I try to log in to my account or redeem gift cards, I get a message saying "Connection Manager Invoke Failed to find a service connection url".  I changed my password, logged out and the same thing keeps happening.  Does anyone have a solution for this?

    Hello,
    Try to go to the settings on your phone... Settings > Store > Click your Apple ID: And sign out from your account, then sign in again .... This solved the problem for me on my iPhone 4s

  • I can't log on to itunes account. Keep getting the error: Connection Manager::invoke::Failed to find service connection url. What can I do?

    I can't log on to my itunes account. Keep getting the error: "Connection Manager::invoke::Failed to find service connection url". What can I do?

    Hi, Buster1932.
    I would recommend logging out of your account then logging back in.  If the issue persists, see the article below. 
    iTunes: Advanced iTunes Store troubleshooting
    http://support.apple.com/kb/ts3297
    Cheers,
    Jason H. 

Maybe you are looking for

  • Difference Between Applet and Swing

    Difference Between Applet and Swing

  • Upgrade windows 8.1 is not showing in store

    Dear Team, Greetings for the Day! We are using windows 8 pro. We wish to upgarde with windows 8.1 pro. We are following below process: 1) We have already windows update in windows 8 pro. 2) We are not getting any option upgrade 8.1 in store. Note: Pl

  • Same file name from sender to receiver file adapter with out using UDF

    Hi All, I am working on FILE TO FILE. My requirement is same file name from sender to receiver file adapter. Is it possible to do using only Adapter Specific message properties?  i mean with out using UDF. Thanks Karthik

  • XI as middleware between Portal & R3

    Hi, I have a customer woh is considering implementing R3 & Portal. Does anyone can tell in avarege what is the overhead in performance if the XI comes between the portal & R3 ? what will be the pros & cons implementing XI in this scenario ? thanks

  • Adobe reader x will exit after about 10 seconds

    adobe reader x (10.1.2 ) will exit after about 10 seconds. I have xp (sp3), almost g gigs of ram, pent 4, 2.8 ghz, I have totaly erased and reloaded reader, flash, no luck. I load it independently and as soon as I get to a document it counts out the