Limits for Numeric Test

Hi All,
I am trying to load limits for a numeric test from an excel file.
I have couple of questions on this.
1. For exporting these values using “Import/Export
Properties”, when I press limits, I get “CompExpr”, “Limits.HighExpr” & “Limits.LowExpr”
in Selected box automatically. But in Limit tab, if mention “Limits.HighExpr”
& “Limits.LowExpr” I get error. But I can load the values with “Step.Limits.Low”
& “Step.Limits.High”. Is it correct?
2. In Limit Tab, I have tried all the option
for loading “CompExpr”. In my Excel file, against “CompExpr”, I mentioned “GELE”,
“GELE (>=<=)”, “GELE (>= <=)”…… But I get error
always. Can you please help me
I have attached .seq and .xls file.
TestStand Version is 4.2.
Thanks,
Sanad MM
Solved!
Go to Solution.
Attachments:
Numeric Test.seq ‏9 KB
Numeric Test Parameters.xls ‏17 KB

Hi,
Could anyone can help me to solve the issues in loading comparision string?
Thanks in advance.
Sanad MM

Similar Messages

  • Report limits for individual tests

    Hi All
    I have a system under test which I interrogate (via RS232) for embedded hardware and firmware information. The reported response has to be added to the final test report along with all the other specified test cases.
    e.g.
    Operator:  xyz
    Date:  xyz
    UUT Type: xyz
    Serial Number: xyz
    PTS 2.1 Embedded H/W (Processor)  12345 version A  12345 version A
    PTS 2.1 Embedded H/W (Amplifier)    23456 version B  23456 version B
    PTS 2.1 Embedded H/W (Filter)         34567 version c  34567 version c
    PTS 2.1 Embedded H/W (Pre-Amp)   45678 version D  45678 version D
    PTS 2.2 12V OFF Current                  2.1mA  5  LT
    PTS 2.2 12V ON Current                   250mA  300  LT
    etc
    etc
    The only way I can think of to get the information into the main body of the report is to perform a 'String Value' test on it. However I then get the limits displayed in the report as well making the final report look messy. I do need all the limits in the report for the usual test cases e.g. voltages, currents etc so I cannot turn off limit reporting in the configuration  report options.
    Is there a way to turn OFF the limits reporting for individual test cases?
    Regards
    IanR

    What version of TestStand are you using?
    You could change the step to an 'Action' step and put the RS232 string in the report text for the step?  It depends on how your report options are setup in your environment.  Where I work, we do not put any Action steps in the report just Pass Fail results.  Hence you would have to change the Status Expression for your Action step to something other than "Done"....
    Otherwise in TestStand 4.0, you can click on the Property Browser view under the Properties Tab.  Right Click on the Limits container and select 'Advanced -> Edit Flags'
    Within that box there is an option 'Is Limit' checked, perhaps by unchecking this option it will not be put in the report.  Although I would NOT do this, because it is difficult for anyone taking over your code ( unless you document you changed this flag ) to see that it is unchecked.
    Thanks,
    Paul Holzrichter

  • How to auto set one numeric test step's limits?

    i want to auto set a numeric test step's limits ,the limit's value is got from one number control and one offset control in LV front panel of my programm.when i change the number control in my fronet panel of LV, and it will auto set the limits to my step in teststand.How to realize it? Using local variable or...?? pls help me and give me a example source code.thanks

    Hi,
    You should use the SetValNumber VI off of the TestStand Palette on your Controls Palette. The property you are trying to set is for the step and is identifed by the lookup string(s):
    "Step.Limits.High", and "Step.Limits.Low"
    Have a look at the examples inside of \Examples\AccessingPropertiesAndVariables\UsingLab​VIEW\AccessingPropertiesAndVariables.seq.
    Bob

  • Different decimal point character for numeric limit test vs multiple numeric test with database logging

    Hi all,
    I have a problem with decimal point character and database logging.
    I've deselected "Use Localized Decimal Point" in Station Options->Localization. Teststand should now use "." as decimal point character (ignore the "'s).
    When logging to database this is only true for Multiple numeric limit test results, not for Numeric limit test results.
    Numeric limit test results use "," as decimal point character where it should be "."
    I can't trust the localization settings on the PC as different endusers might have different settings.
    Example:
    (STEP_NAME and PROP_RESULT.DATA)
    Numeric limit test 1,50127667932332
    Multiple numeric limit test result_1 1
    Multiple numeric limit test result_2 1
    Multiple numeric limit test result_3 10.0304317
    I've changed the Limits->Numeric format for each test but this change is only applied to the report, not the database result.
    Read the manuals but didn't find anything...
    Have I missed something obvious, or is this some kind of bug?
    Teststand version is 2010.
    Windows versions are XP SP3 and Win7. Same behavior on both OS.

    When something is logged to the database as a number, the database is probably storing it in a way that is independent of any sort of decimal point localization. When you view the items in the database however it is probably going to show you the number based on the current locale settings. This is likely purely cosmetic, for display purposes.
    -Doug

  • Creating custom edit step (LV) for multiple numeric test

    Hello,
    i want to write a custom edit step (LabView) for a custom multiple numeric test (TestStand 3.0). It should be the replacement for the editmultinumericmeasurementstep. Have anybody done this before and example code or a solution?
    greetings schwede

    Hello,
    thankyou for your answer. But it doesn`t help. I know how to create a custom step type. But I want to create a custom multiple numeric limit test step type with a custom vi as the editmultinumericmeasurementstep. It is quiet difficulty, because i want to create my own measurements (see the attachment). The name of the test should not be measurement 0 or 1 but LED test color oder LED test intensity.
    greetings schwede
    Message Edited by Schwede on 12-06-2007 02:42 AM
    Attachments:
    Test.rtf ‏1414 KB

  • Multiple numeric test measurment name vb6

    I am trying to obtain the names of Multiple Numeric Test measurements from Visual Basic (vb6).
    I have read the knowledgebase article 2NE7K56E which gives excerpts from an example for LabWindows/CVI
    and am getting closer, but no solution yet.
    Here is what I have and the error I get:
        Dim stepAsPropObj As PropertyObject
        Dim measAsPropObj As PropertyObject
        Dim sName as String
        stepAsPropObj = currentStep.AsPropertyObject()
        i=0
        Do While (existsMultiResults)
            'the following works to obtain upper limit
            limitsArrayHigh(i) = FormatNumber(stepAsPropObj.GetValNumber("result.measurement[" & Format(i) & "].limits.high", 0), 3)
            'the following statement gives the error "Specified value does not have the expected type":
            measAsPropObj = stepAsPropObj.GetPropertyObjectByOffset(i, 0)
            sName = measAsPropObj.Name   'dont know if this works or not. not getting this far.
        Loop
    It seems that "result.measurement" has to be specified somewhere,
    but everything I try gives a different error.
    Can anyone show me how to do this.
    Thanks very much.
    Jon  

    Jon,
    I'm not sure at this point why you are getting the error when trying to access the name of the Measurement.  This is one of those cases where it might be easier for me to send you a small example that reads the measurement's name in VB.  This might be easier than me trying to find out what is the difference between your code and mine.
    Make sure to re-link the .Net assembly to point to the new location where you decompress the files.
    Let me know if this works on your computer and what differences you see between this and your code.
    Regards,
    Santiago D
    Attachments:
    Measurement_DotNet.zip ‏37 KB

  • Limitation for CLOB columns? - ORA-01704: string literal too long

    Hello!
    I'm trying to update a CLOB column with more than 35000 characteres, but I get "ORA-01704: string literal too long".
    The code:
    declare
    l_clob clob;
    begin
    update test set test = empty_clob()
    WHERE ID = 1
    returning test into l_clob;
    dbms_lob.write( l_clob, length('A...here 35000xA...A'), 1,'A...here 35000xA...A');
    end;
    Is there any limitation for CLOB columns?
    Thanks for help.
    Daniel

    user605489 wrote:
    32768 characteres :)Actually it's 1 character less than 32K...
    *32767*
    SQL> declare
      2    v_vc varchar2(32768);
      3  begin
      4    null;
      5  end;
      6  /
      v_vc varchar2(32768);
    ERROR at line 2:
    ORA-06550: line 2, column 17:
    PLS-00215: String length constraints must be in range (1 .. 32767)
    SQL>I guess it comes from a legacy thing where signed words (2 bytes) are/were used to represent a value. As the most significant bit of the word is used to represent the sign of the number the range goes from -32768 to 32767.

  • Increasing Email Size Limits for some users

    Hi All,
    For some users (management) i needed to arrange that they are able to send bigger files then the default 10MB limit to each other.
    I used this procedure to do so,
    https://www.simple-talk.com/sysadmin/exchange/increasing-email-size-limits-for-your-high-profile-users-in-exchange-2010/
    In a nutshell:
    Set Global Transport Org. Config to 200MB
    Set Transport Send and Receive connector to 200MB
    Created a Distribution group adding the MT members and me (for testing)
    Created a transport Rule for the 10MB limit for all users and exception for the distribution group
    (Believe me, i am not happy with the 200MB size limit)
    All seems to work but i have one issue that i cannot tackel or maybe it is by design.
    -Managemant can also send big files to all
    users who do not have this privelige, this is not someting i want, sending 100MB+ attachments to over 150 users.
    Is this by design or do i mis something?
    Thanks,
    Ron

    Hi RonGielgens,
    Attachment size in exchange has to be set on
    Global settings
    Connectors (send and receive connectors)
    Mailbox
    The global settings will affect all the others. of course connectors will affect specific servers and mailbox one user. You have to set the global to the absolute max size you want to allow in your organization.
    after you do this you will need either to set the 10MB on each mailbox
    Get-Mailbox | Set-Mailbox -MaxSendSize 10MB -MaxReceiveSize 10MB
    Then change the limit on specific mailbox
    or another way is to create a transport rule that will reject the email if the attachment size it > 10MB unless the sender/recipient is the required user or group.
    so basically create 2 transport rules
    1. reject messages sent to anyone with attachment > 10mb unless the recipient is userX
    2. reject messages sent from anyone with attachment > 10mb unless the sender is userX
    Normal case it should not allow.
    Thanks, MAS
    Please mark as helpful if you find my comment helpful or as an answer if it does answer your question. That will encourage me - and others - to take time out to help you.

  • Export Limits for Multiple Sequences in the Same Sequence File for TS3.0

    Hi,
    I am using TestStand 3.0 to a test application. Because we want to have our limits in a csv-file I have tried to use the Import/Export tools in TS. But this application only supports to export limits for the selected sequence (e.g. main, or subseq1) at a time. This makes it a pretty hard job to export limits from 30 test sequences. What I need is a possibility to export my limits from �all sequences� in my seq-file.
    I have found an article on NI Dev. Zone about �Export Limits for Multiple Sequences in the Same Sequence File (TestStand 1.0.x)�.
    http://sine.ni.com/apps/we/niepd_web_display.DISPLAY_EPD4?p_guid=B45EACE3D9CB56A4E034080020E74861&p_node=DZ52236&p_submitted=N&p_rank=&p_answer=&p_sourc
    e=External
    I have tried to use this code but because it�s for TS 1.0.2 the limits from my multi num test step and my custom steptypes isn�t exported. So that doesn�t fulfill my needs.
    Is there an updated version with �all sequences� added to TS 3.0? Is there other good solutions to my problem out there?
    Best Regards,
    Morten Pedersen
    CIM Industrial Systems A/S
    Denmark

    Hi David Mc,
    Thanks for your reply. I have already considered this solution because the source code is added in the folder described in your reply. But that is not a good solution. It will cost me a lot of time to establish the toolchain, reverse engineer the source code, make the implementations and build a new dll (most off these is already knowledge by NI). And when NI make future releases of TestStand I have some merge work to do every time NI have made some changes in the files I have changed.
    But as I write above: I have hoped that NI already has/or could made a solution like the one to 1.0.2 (see link in root) to me. And then they could include it in the next version.
    I don't think I am the only one in the TestStand world that ne
    ed this feature.
    Best regards,
    Morten Pedersen
    CIM Industrial Systems A/S
    Denmark

  • Equipment for building test lab

    Hello all,
    I'm looking for a little input on the two options I'm weighing for building my virtual test lab. If at all possible, I would rather not have my daily PC running my virtual lab, but I leave that option open. I'm thinking of purchasing a Dell PowerEdge 2950 II
    (from ebay), installing Windows Server 2008 R2, installing VM VirtualBox so that I can set up an Active Directory environment to prepare me for the MCITP exams. This option would allow me to conserve the resources of my daily PC. If I were to use my daily
    PC (I7 quad, 3GB RAM, 80GB SSD, and 1TB storage with only 200GB of free space) I would more than likely have increase RAM and buy another HDD to store the VMs. How much more trouble would it be to go the PowerEdge 2950 II route?
    Thanks.

    Hi,
    We recommend that you review the Windows Catalog to identify servers that are qualified for use with Hyper-V. You can identify systems that support the x64 architecture and
    Hyper-V by searching the Windows Server catalog. Personal advice is you’d better to buy the 2950III
    it’s the newer product.
    More information:
    Requirements and Limits for Virtual Machines and Hyper-V in Windows Server 2008 R2
    http://technet.microsoft.com/en-us/library/ee405267(WS.10).aspx
    Hope this helps.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Can we Install SQL Server Express with Advanced Services x 64 bit for our testing purpose without procuring any license? Also can we use it for commercial use if we are neglect risk sof using it on Production?

    Can we Install SQL Server Express with Advanced Services x 64 bit for our testing purpose without procuring any license? Also can we use it for commercial/Production
    use if we are agree to take risk of using it on Production?

    Hi,
    Yes you can, but you should be aware of the limitations of MS SQL Express version.
    1. 1GB RAM
    2. 10 GB database size per database excluding log file (SQL 2008 R2 and above)
    3.Job Scheduling service is not available with SQL Server Express.
    4.Data import and export feature is not available with SQL Server Express.
    5.Limitation on number of CPU
    Refer following article for features supported by different editions of MS SQL Server.
    Features Supported by the Editions of SQL Server 2012
    Please mark solved if I've answered your question, vote for it as helpful to help other users find a solution quicker
    Praveen Dsa | MCITP - Database Administrator 2008 |
    My Blog | My Page

  • Format mask for Numeric and Data data

    1)Is there any way to suppress timestamp for 12:00:00 value from a date column with TO_CHAR? except that value we should display time value for date column, like this
                 01/12/2009 01:15:01  , 01/12/2009 12:00:00
                 this should be like
                 01/12/2009 01:15:01 , 01/12/2009
                 2) Can I display "0." decimal infornt of numeric value? I used to_char('0.1','9999990.99') , but its displays leading spaces How can I toggle fm for numeric values ?
    Thanks,
    Hesh.
    Edited by: Hesh on Jun 23, 2009 12:27 AM

    A slight change to Michael's query (corrected a small typo)
    SQL> WITH test_tab
      2         AS (SELECT   SYSDATE date_col FROM DUAL
      3             UNION ALL
      4             SELECT   TO_DATE ('26/06/2009 12:00:00', 'DD/MM/YYYY hh24:MI:SS')
      5               FROM   DUAL)
      6               -- end test data
      7  SELECT   date_col,
      8           TO_CHAR (
      9              date_col,
    10              CASE
    11                 WHEN TO_CHAR (date_col, 'hh24:mi:ss') = '12.00.00'  -- typo error '.' instead of ':'
    12                 THEN
    13                    'dd.mm.rrrr'
    14                 ELSE
    15                    'dd.mm.rrrr hh24:mi:ss'
    16              END
    17           )
    18              dt
    19    FROM   test_tab
    20    /
    DATE_COL             DT
    23-JUN-2009 13:29:42 23.06.2009 13:29:42
    26-JUN-2009 12:00:00 26.06.2009 12:00:00
    2 rows selected.
    -- corrected query --
    SQL>   WITH test_tab
      2         AS (SELECT   SYSDATE date_col FROM DUAL
      3             UNION ALL
      4             SELECT   TO_DATE ('26/06/2009 12:00:00', 'DD/MM/YYYY hh24:MI:SS')
      5               FROM   DUAL)
      6               -- end test data
      7  SELECT   date_col,
      8           TO_CHAR (
      9              date_col,
    10              CASE
    11                 WHEN TO_CHAR (date_col, 'hh24:mi:ss') = '12:00:00'
    12                 THEN
    13                    'dd.mm.rrrr'
    14                 ELSE
    15                    'dd.mm.rrrr hh24:mi:ss'
    16              END
    17           )
    18              dt
    19    FROM   test_tab
    20  /
    DATE_COL             DT
    23-JUN-2009 13:29:44 23.06.2009 13:29:44
    26-JUN-2009 12:00:00 26.06.2009
    2 rows selected.
    SQL>Regards,
    Jo

  • Microsoft Office 2004 for Mac Test Drive query

    does this software have a time limit as to how long i can use it for?
    im gettin a new imac, and wondering if i will have to purchase microsoft office 2004 as well as the "Microsoft Office 2004 for Mac Test Drive" that comes with it.
    any help would b much appreciated
    thanks

    According to http://www.microsoft.com/mac/default.aspx?pid=office2004td the test drive is good for 30 days. Click on the *more info* link to see other limitations. The student edition (available to anyone remotely connected with it) is available for $125 US or cheaper.

  • So I think there should be an app with flash cards that you can fill in your own info with. I'm studying for a test, and how awesome would it be to have my flash cards on my phone!!! Is there already an app like that?

    I think there should be a flash card app that let's u put in ur own info. I'm studying for a test and I think it would be really cool to have my flash cards in my phone!! Is there an app like that already?

    http://www.appshopper.com/education/flashcards

  • Not getting BI query variable selection screen  for few test users

    Hi,
    i am having problem when i am executing the reports. i am not getting variable screen for the test users ID's. but i am getting the screen when when 0BI_ALL authorization selected.
    i want role based authorization, and not complete authorization.
    the parameters in su01 are scl(X) and wlc(X   X  XX   X)
    Thanks,

    Can you please check into Infoobject Maintenance screen in Bex Tab i.e. Query Execution Filter Value Selection. assign "Values from Masterdata Table".
    Try again and let me know.
    Nagesh Ganisetti.

Maybe you are looking for

  • Can I "reset" hard drive capacity

    I'm not sure how it happened (although I suspect it was during an aborted install of Bootcamp), but an 80GB external (firewire) hard drive now shows up as a 55GB hard drive. I have tried everything I can think of -- well, OK, Disk Utility -- but I ju

  • Using the Data Engine Java API

    I try to use the Data Engine Java API to generate an XML document from database data. So as mentioned in the documentation Business Intelligence Publisher User's Guide Release 10.1.3.2 (page 4-26 to 4-27) a) I created a java class (using Jdev Version

  • How to use real-time tracking and filing in EchoSign

    Click the link to learn how to use the notification, tracking, and filing features available in the Adobe electronic signatures service, EchoSign.

  • BPM ALERT

    Hi All, I have configured Alert in alertcatdef, checked everything in RWB , everything works fine till now. But in my BPM scenario two steps in our Integration Process: Container operation and  Control step are defined.No errrors in BPM,when i execut

  • How to get selected Cell value in datagrid?

    Hi guys, I have a datagrid that is editable. I was wondering if it's possible to retreive the cell value after user edits the single cell. My datagrid will trigger griditemEditorSessionSave event if users finish the editing, but I don't know how to g