XIR2 on Windows: on the webi report server, the lowest value I can use for the setting "Maximum Simultaneous Connections" is 5.
Is there any way I can change this manually, possibly in the registry so this value can be set as "1"?
Thanks in advance
R

The important thing to realize about wireless is that it's a shared medium and only one device can transmit at any one time on a given channel so the number of users per AP will depend largely on what sort of traffic you'll be putting over the wireless.
If you expecting it to replace structured cabling in an office environment then you can probably expect quite a bit of data, especially if you have a Windows domain and fat clients.
I wouldn't put more than 7 - 15 users per radio (depending on load)
If you install a dual radio AP - something like an 1142a/g/n, then you can split the users between the two frequencies (assuming that some of the clients support 802.11a) and if they support N then that's even better
For that number of users I would strongly suggest you install 3x APs (dual radio), that way you can have 3 non over-lapping channels in the 802.11g frequency and will be able to provide the best possible performance to the users
As a side note you should also connect the APs to Gigabit ports so that you get the benefit of the higher throughputs provided by 802.11n
Cheers,
John
Sent from Cisco Technical Support iPad App

Similar Messages

  • Maximum Simultaneous Connections??

    In the server admin for Leopard it has a default 1024 for maximum simultaneous connections. The most you can enter in the server admin is 2048.
    Is there a way to edit some files to allow for 10,000 simultaneous connections?

    Specifically which service are you talking about?
    I'm guessing you're talking about web services, but it's important to say so because each service has its own set of limits.
    That said, 1024 is a LOT of connections for any web server. Don't forget that only applies to actual active connections - people downloading a page from your server. Once the page is served the connection is available for some other user. It may take the original user a few seconds to read the page before they click a link and go to the next page.
    For reference, I run many sites with millions of page views per month and most of my servers sit in single, or maybe double-digit numbers of active connections at a time.
    If you think your site is really going to have thousands of simultaneous active users you probably need to look at what you're doing and scale across multiple servers rather than trying to run that much traffic through a single machine.

  • What to set maximum simultaneous connection to?

    Hello
    What do I set maximum simultaneous connection to (web server settings)? In Apache manual you can calculate "maxClient" by taking the avaiable free RAM and split that with the memory each httpd process using. In my case that would be: 6000 / 15 = 400 maxClient.
    But in Apples "Web tech admin" pdf they write: "...Browsers often request several parts of a webpage at the same time, and each request creates a connection". Does that really mean that every image need a separate connection – or have I missunderstand anything?
    At the moment I have it set to the default 1024. But, CPU usage is very often in the 90-100% region… So, should I go by Apache's definition or Apples default?
    Best regards, Magnus

    You'll want to look at where the CPU time is going across everything that is going on, and at how much memory is in use; at a more holistic approach toward tuning.  Unless you're getting a substantial load on Apache or unless you're very marginal on available memory, tweaking the maximum processes isn't usually a huge win.
    If you are looking at comparatively large volumes of http traffic and that 90-100% CPU is largely web-related, then you'll want to profile the server using the Safari or other tools, and look at optimizations and at web caching, and potentially at adding web servers.
    And yes, a web browser can have multiple parallel connections into a web server.
    The maximum connections stuff sets up the numbers of Apache http client processes, which is why you're looking at memory with that discussion you've found.
    Something similar to this command will get you the accumulated CPU time and the memory (rss) size for the Apache processes:
    ps -A -o ucomm,rss,time | grep -i httpd
    There are Apache tuning articles around the 'net, but I'd first make sure it's Apache that's soaking up the CPU time and not some other constraint.

  • Upload Maximum Date Rate Lower Than Upload Data Ra...

    Hello there,
    I have just brought up my BT Home Hub 5 stats and my upload data rate is higher than my upload maximum date rate. Is this normal? My upload noise margin has dropped to 4.9 - 5.1 dB. I've had BT Infinity just over 2 days and was wondering if this was normal for FTTC connections?
    Many thanks,
    William

    normally the data rate will be lower than max data rate but yours is that close I would not bother unless it starts to affect your connection which is unlikely
    If you like a post, or want to say thanks for a helpful answer, please click on the Ratings star on the left-hand side of the post.
    If someone answers your question correctly please let other members know by clicking on ’Mark as Accepted Solution’.

  • Maximum simultaneous connections for WRT350N

    Hi,
    What is the maximum number of simultaneous connections that the WRT350N router can handle whilst allowing 1 user to surf the internet?
    I need to know this so I can set the maximum number of connections in uTorrent. My upload speed is 1.1 mbps, which is roughly 140 kBps.
    The PC has a direct connection to the router, the wireless has been turned off.

    There is no such defined number of user for TCP/IP connection.However,you can try to tweak the settings on the application and check if that helps.read this link and this link.

  • WiFi Hotspot Maximum Simultaneous Connection

    Hello,
    does anybody know how many simultaneous connections can be made with an iPhone Wifi Hotspot?
    Thanks, cheers

    CDMA model: 5, GSM model: 3.

  • What is the maximum number of users that can be simultaneously connected to a shared drive on an Airport Extreme

    What is the maximum number of users that can be simultaneously connected to a shared drive on an Airport Extreme?

    50
    I haven't tried this, but imagine that things are going to be quite slow.

  • Simultaneous connection of more than one unit of GPIB device

    Dear all out there,
    Would anyone has any idea/ solution in programming of ATE that makes Simultaneous connection of more than one unit?
    What's the better, if not the best, way of initialisation, acquisition and report generation for such system? without significant delay incurred.
    For instants,
    1. Initialise X number of, say, Agilent 34401A multimeter (GPIB)
    2. Acquiring of meter readings from each meter, limit check and write to respective report
    Any idea/ sample code/ solution is very much appreciated.
    Regards
    ian.f k
    Ian F
    Since LabVIEW 5.1... 7.1.1... 2009, 2010
    依恩与LabVIEW
    LVVILIB.blogspot.com

    albert geven wrote in message news:<[email protected]>...
    > The connection of multiple multimeters to the gpib bus is normal, the
    > only thing you need to do is switch them each to a unique address on
    > this bus.
    > Your program can best initialise all multimeters once in the beginning
    > of your program and read out those meters when appropriate.
    With many instruments there are two types of "initialise."
    One type, which is a reset, choose range, etc., as you suggest can
    be done at the beginning of a program or section of a program.
    However, the other type of initialize is to sent the SCPI INIT command
    to the instrument. This command tells the instrument to take a measurement
    (or scan of measurements).
    When dealing with multiple multimeters, there are at least 2 ways of
    handling measurements. The slow way deals with one instrument at a
    time -- using the SCPI commands INIT, wait FETCH?, or perhaps just READ?
    sent to each instrument. It is slow because each instrument must wait
    for the previous instrument to finish before it can start.
    The better way is to set up each instrument for the desired measurement.
    If simultaneous triggering is needed, either use some type of external
    trigger or BUS trigger if the instrument can use it. After all instruments
    are set up, issue the INIT command to each instrument, then trigger.
    when all measurements are completed, use the FETC? command to get the
    results from each instrument. Note that there may be Plug&Play drivers
    to issue these commands for your instrument.
    [email protected]
    www.CompleteTest.com

  • AIR-LAP1131AG-E-K9 maximum of simultaneous connections

    Hi,
    Does any body know what is the maximum of simultaneous connections that the AIR-LAP1131AG-E-K9 access point supports?
    Any help is much appreciated!

    Currently it is suggested around 25 devices per radio. It really depends on the bandwidth that is required by applications. I have seen 50+ on and ap with just web and email traffic. I have also seen up to 4 with video transfers.
    I know with the 7.2 code, you can specify they max user per radio or ap.
    Sent from Cisco Technical Support iPhone App

  • Simultaneous connections with different logins

    Hi,
    We have successfully configured our CR25wiNG to work with our AD (tight integration).
    From time to time, we need to connect to a file server (Windows Server 2012) using RDP
    with a specific user. After logged in to the server, Cyberoam disconnect the former
    user and automatically redirect to the captive portal page.
    How can we avoid this behavior ?
    This topic first appeared in the Spiceworks Community

    Hi pyro61,
    Unfortunately there's not a really great solution for you.  The
    way an SCXI chassis works is that it multiplexes all of the channels
    that are in the scan list.  The only way that you can get rid of
    some of the samples would be to do it in software and programmatically
    look at only half of the data except for that one point per second that
    you want.
    You can either sample all 64 channels at their maximum rate
    (200 kS/s / 64 = 3,125 S/s), or you can pick some rate lower than that
    rate.  If you need to sample the different modules at different
    rates then you will have to have those different modules in different
    chassis.  Otherwise you are limited to one rate per chassis.
    Note: If you have the modules configured for parallel mode,
    then you could read multiple modules at multiple rates; however, in
    your case this will not work because you are only using one DAQ board
    (the SCXI-1600),
    the modules you are using are not supported for parallel mode, and
    because you can only read 8 channels at a time when in parallel mode.
    My best recommendation would be to sample as fast as you can, and then discard the unwanted thermocouple data.
    Regards,
    Otis
    Training and Certification
    Product Support Engineer
    National Instruments

  • Connect more than 3 ATV's at the same time to one iTunes Library.

    Seriously! Im about to go nuts on this!
    I have a big problem, I have 13 ATV's, 1 x MacMini witch has two external drives on 1TB containing film attached to it.
    I want to be able to connect all the ATV's to the same iTunes library, I know that you cant stream to 13 ATV's simultaneously. I just want them to be connected to the library so i dont have to run to the computer to connect another one just because you change location inside the boat.
    I have been in contact with Apple Pro support numerous of times regarding this and the only answer you get it pretty much.. this is the way it is.. like it or not..
    Have contacted Royal Caribbean Cruise ships yard down in Miami to try getting hold of the guy who had to do with the 1400 iMacs the had installed on their vessels. Not received a reply from him yet..
    Does anyone else have any tips on how I can approach or try to contact?
    I know that me with my few ATV's is a man with no voice when it comes to speak to Apple about this problem.. But the thing is that i am working as an IT Officer on a private owned yacht 70m+ and have allot of contact with other IT guys from other private owned vessels (read hundreds of hundreds private owned yacht around the globe) how was like me.. looking for a nice, quiet good looking pice of equipment with a nice, easy to use interface that isn't going to cost 100 000€.. If you start looking at it in that way, my 13 ATV' all of a sudden could been 1300? or maby even 13 000? when you start counting on potential yachts around the globe..
    I mean i understand why Apple have limited their iTunes to not be able to handle more than 3 ATV's at the same time.. but i still think its wrong to cut all possible changes to make it able to connect more than 3 external medias to the same library. They could have made a solution like what they have done with the Quicktime for example.. the player that comes standard in OSX is the basic one.. go online pay "what ever amount" and whips you have a pro version.. could have done exactly the same thing when it comes to iTunes.. basic pre installed.. buy a code in apple store and whips you have pro features..
    It cant just be me in the hole world ho has this problem?!?!
    Incredibly grateful for answers or thoughts.
    Best regards Timpos

    AC, Thank you for you reply.
    Even though it is supposed to be a 'simple' home video system it has so much potential!
    And i mean i know there is an solution since i know the Caribbean cruises are using apple as media centers onboard their ships. have to admit that i do not know if they are using frontrow or some other application created buy some other company.. i just know that some one must know how to get around it all and make it work..
    Just wish i had someone to get in contact with that is working hands on every day with this product, and get strait, good, final answers.. no "pro support" since im not happy with their answers anymore..
    I know i start to sound desperate.. but thats because i am..

  • Simultaneous connections to the same server from IE and NN

    Hi,
    We are using iws4.1.
    IE5+ can make only atmost 2 simultaneous connections to our server and
    NN makes 4 connections.
    We found certain pages hosted by iws4.1 like www.netscape.com can make
    more than 2 simultaneous connection from same browser.
    The above tests are done from a dialup connection
    Is there a way to increase the no. of simultaneous connections from both
    IE and NN with the knowledge on the end user.
    Thanks in advance
    rvenky

    Could you please post the code, if you do not mind. Also if you could post the connection pool definition of both the pools that would help too.
    If the business method is coded in the following way
    m1() {
    conn1 = // get connection
    conn2 = // get another connection
    // do some thing with conn1
    // do some thing else with conn2
    conn1.close();
    conn2.close();
    Could you try modifying the code in the following way and see if that helps
    m1() {
    conn1 = // get connection
    // do some thing with conn1
    conn1.close();
    Basically start using conn2 after conn1 is used
    conn2 = // get another connection
    // do some thing else with conn2
    conn2.close();
    regards
    sankar

  • Max number of simultaneous connections?

    Hi everyone!
    how is possible to determine in advance the max number of simultaneous connection for my FMS?
    thanks!

    Hi,
    Like Jay had mentioned the limitation on the number of connection to server depends on the capability of your server.
    You can get the maximum number of connections made to the server, number of active clients... etc details through Administration APIs.
    'getServerStats' gives you the "total_connects", which is the maximum number of connections made to the server. "connected" property will return the number of active clients to your server at one point. It also has many more statistics for your reference. This api returns the overall information of the server. If you want to get the details for specific vhost, you can use getVHostStats or getActiveVHostStats. To get more details on Administration API, refer your pdf documentation on "Administration API", that gets installed in your system under "$Root\Flash Media Server\documentation\flashmediaserver_3.5_administrationAPI.pdf".
    Regards,
    Janaki L

  • Lower than expected battery life? (pic warning)

    I have the x61s w/ the UltraLight screen and 4-cell cylindrical battery. According to the specs I should be getting up to 4.5h.From what I've heard, lenovo's estimations are actually normally quite accurate.
    Well here's the thing - I probably top out at about 3hrs. This is QUITE a bit lower than expected. Could it be a faulty battery? I'm expecting more out of this baby!
    Message Edited by Kaitlyn2004 on 05-01-2009 07:13 PM
    Message Edited by JaneL on 05-01-2009 10:59 PM

    The 4.5 hours estimate is when you don't use your laptop for anything other than word processing, and dim out your LCD. In addition it would also require you not use any wireless connection or lot of background processes.  
    You can check your battery condition, by going into power manager and look at what is the design capacity and actual capacity?
    Message Edited by JaneL on 05-01-2009 10:59 PM
    Regards,
    Jin Li
    May this year, be the year of 'DO'!
    I am a volunteer, and not a paid staff of Lenovo or Microsoft

  • Help needed : javamail Too many simultaneous connections

    Hello
    i'm using javamail to develop a webmail
    i've created a service Class , and all things works well , but i have a serious problem when i browse my webmail ( viewing folders: inbox / spam / etc or messages) i get an error saying :
    Too many simultaneous connections. (Failure)
    i know that the imap server dosen't support more than 10 simultaneous connections.
    But i can't say to users using my webmail to do not a lot of actions !!! , and also when i use thunderbird for example it works fine without errors even if i do a lot of actions/connections
    How can i solve that problem ?
    Thanks
    A1 OK [email protected] authenticated (Success)
    A2 CAPABILITY
    * CAPABILITY IMAP4rev1 UNSELECT LITERAL+ IDLE NAMESPACE QUOTA ID XLIST CHILDREN X-GM-EXT-1
    A2 OK Success
    A3 SELECT INBOX
    DEBUG: no connections in the pool, creating a new one
    * FLAGS (\Answered \Flagged \Draft \Deleted \Seen)
    * OK [PERMANENTFLAGS (\Answered \Flagged \Draft \Deleted \Seen \*)]
    * OK [UIDVALIDITY 616267767]
    * 7 EXISTS
    * 0 RECENT
    * OK [UNSEEN 1]
    * OK [UIDNEXT 90]
    A3 OK [READ-WRITE] INBOX selected. (Success)
    A4 STORE 1 +FLAGS (\Seen)+
    +* OK Gimap ready for requests from MyIP 24if2631473eyx.55+
    +A0 CAPABILITY+
    +* 1 FETCH (FLAGS (\Seen))+
    +A4 OK Success+
    +* CAPABILITY IMAP4rev1 UNSELECT IDLE NAMESPACE QUOTA XLIST CHILDREN XYZZY+
    +A0 OK Thats all she wrote! 24if2631473eyx.55+
    +A1 LOGIN myemail mypwd+
    +A1 OK [email protected] authenticated (Success)+
    +A2 CAPABILITY+
    +* CAPABILITY IMAP4rev1 UNSELECT LITERAL+ IDLE NAMESPACE QUOTA ID XLIST CHILDREN X-GM-EXT-1
    A2 OK Success
    A3 SELECT INBOX
    * FLAGS (\Answered \Flagged \Draft \Deleted \Seen)
    * OK [PERMANENTFLAGS (\Answered \Flagged \Draft \Deleted \Seen \*)]
    * OK [UIDVALIDITY 616267767]
    * 7 EXISTS
    * 0 RECENT
    * OK [UNSEEN 1]
    * OK [UIDNEXT 90]
    A3 OK [READ-WRITE] INBOX selected. (Success)
    A4 STORE 1 +FLAGS (\Seen)
    * OK Gimap ready for requests from MyIP 23if2388548eya.46
    A0 CAPABILITY
    * 1 FETCH (FLAGS (\Seen))
    A4 OK Success
    * CAPABILITY IMAP4rev1 UNSELECT IDLE NAMESPACE QUOTA XLIST CHILDREN XYZZY
    A0 OK Thats all she wrote! 23if2388548eya.46
    A1 LOGIN custom.infoma1 mypwd
    A1 NO [ALERT] *Too many simultaneous connections. (Failure)*
    A2 LOGOUT
    * BYE Logout Requested 23if2388548eya.46
    A2 OK Quoth the raven, nevermore... 23if2388548eya.46
    A4 CLOSE
    A4 CLOSE

    Thunderbird supports disconnected or offline operation. It can disconnect from the server and then reconnect later
    and synchronize its state, so that you never know it was disconnected.
    You can do that too, but it's a lot of work.
    For webmail, the simplest approach is usually to have only one folder open at a time for each user.
    If your IMAP server is limiting you to 10 connections total, across all users, get a new IMAP server.

Maybe you are looking for

  • Can't remember game center email... HELP!

         My little brother has two game center accounts and accidentally signed out of one without looking at which email he had used.  We have tried every email possible and no luck finding the account he had used.  If you know anything about how to fin

  • IWeb stopped working

    Upgraded iWeb to 1.1.2 and Aperture to 1.5 and iWeb hangs upon startup. I get no response from any button. I really need to use it. What's going on? Thanks for any help.

  • Why CO24 is not reliable transaction for me?

    Dear experts, I launch transaction CO24 to check the missing parts list. However, this transaction also gave me a big lists of materials that were not missing. Thus, I couldn't not fully trust this transaction. After the CO24 report, I have to check

  • Two movement type in sales order

    Hi my client requires a stock to transfer to plant (301 mvt type) to happen at the same time while creating the sales order. for this i added one more movement type in schedule lines (mvt type 1 step) in img. but i am not getting the two schedule in

  • Loading dbwsclient.jar

    Having problems while loading dbwsclient.jar. loadjava -u user/password@dev -r -v -f -noverify -genmissing C:\temp\webservices2\sqlj\lib\dbwsclient.jar This user has all JAVA* roles and create any proc, create any table. Get following type of message