Messages: SFF8472-5-THRESHOLD_VIOLATION

Hi Folks,
I have new switch CISCO WS-C4510R-E with SUP6-E. I am getting following messages on my console.
*Jan 27 03:04:08.515: %SFF8472-5-THRESHOLD_VIOLATION: Te5/2: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -11.3 dBm.
*Jan 27 03:04:09.707: %SFF8472-5-THRESHOLD_VIOLATION: Te6/2: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -11.3 dBm.
What is wrong with my power or something. Below pasted show power and show power modules out put.Do I need to contact TAC? any help is highly appricated.
SW#show power
Power                                             Fan      Inline
Supply  Model No          Type       Status       Sensor   Status
PS1     PWR-C45-6000ACV   AC 6000W   good         good     good
PS1-1                         110V   good
PS1-2                         110V   good
PS2     PWR-C45-6000ACV   AC 6000W   good         good     good
PS2-1                         110V   good
PS2-2                         110V   good
Power supplies needed by system    : 1
Power supplies currently available : 2
Power Summary                      Maximum
(in Watts)              Used     Available
System Power (12V)       1125        1700
Inline Power (-50V)         0         935
Backplane Power (3.3V)     40          40
Total                    1165 (not to exceed Total Maximum Available = 2100)
                             Output Power To Chassis            Input Power
                    =======================================  ==================
Power Measurement   System Power (12V)  Inline Power (-50V)
(in Watts)                (+/- 12W)        (+/- 50W)              (+/- 5%)
PS1                        168                    0                  280
PS2                        156                   50                  343
Total                      324                   50                  623
SW#show power module
                             Watts Used of System Power(12V)
Mod   Model                 budgeted instantaneous  peak   out of reset  in reset
1    WS-X4548-RJ45V+           60         --        --         60          25
2    WS-X4548-RJ45V+           60         --        --         60          25
3    WS-X4548-RJ45V+           60         --        --         60          25
4    WS-X4548-RJ45V+           60         --        --         60          25
5    WS-X45-SUP6-E            260         --        --        260         260
6    WS-X45-SUP6-E            185         --        --        185         185
7    WS-X4548-RJ45V+           60         --        --         60          25
8    WS-X4548-RJ45V+           60         --        --         60          25
9    WS-X4548-RJ45V+           60         --        --         60          25
10    WS-X4548-RJ45V+           60         --        --         60          25
--   Fan Tray                 200         --        --        --          --
       Total                  1125         --        --        925         645
                        Watts used of Chassis Inline Power (-50V)
                        Inline Power Admin  Inline Power Oper
Mod   Model                PS     Device       PS     Device     Efficiency
1    WS-X4548-RJ45V+          0        0         17       16          94
2    WS-X4548-RJ45V+          0        0         11       10          94
3    WS-X4548-RJ45V+          0        0         11       10          94
4    WS-X4548-RJ45V+          0        0         11       10          94
5    WS-X45-SUP6-E            -        -          -        -           -
6    WS-X45-SUP6-E            -        -          -        -           -
7    WS-X4548-RJ45V+          0        0          5        5          94
8    WS-X4548-RJ45V+          0        0         17       16          94
9    WS-X4548-RJ45V+          0        0         11       10          94
10    WS-X4548-RJ45V+          0        0         11       10          94

Hello,
I have same issues on our network on all non Cisco X2 modules starting on nearly the same day (devices have nearly same update). I can't say that it is only cosmetic nature due to the fact that after a lot of these messages happened I registered SPT topology changes. This happened on several of my devices but it is not very often. For our customers it is a two second hit, where services are not available. Our software is on the 15.0 release train so a lot of possibilities to upgrade to higher versions are not given at this time.
Are in the above mentioned Cisco internal Bug (ID CSCth08212/CSCte94616) additional information which can be helpful but are not open to people outside TAC?
With kind regards
Stefan
I forgot to mention that the message in my case describes a lot of temperature alerts (ranging from -130°C up to 130°C) that are violated and less of alerts belonging to the power.

Similar Messages

  • Cisco 2960S SFF8472-5-THRESHOLD_VIOLATION

    Hi All
    I have a issue connecting my Cisco 3750X 12 port fibre switch to my Cisco 2960S 24Port switch using Multi Mode Fibre.
    I have Mode condtioning cables connecting to the SFP (GLC-LH-SMD) on the 3750 via a fibre patch panel which bring me to the 2960s with its Mode conditioning cable and SFP (GLC-LH-SMD).
    The fibre port on the Cisco 2960S was up for all of 10 mins and has gone out with the following error message.
    %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/26: Rx power high warning; Operating value:  -2.7 dBm, Threshold value:  -3.0 dBm.
    I did a show int transceiver command and got the following output.
    DS-THN-SW3#show interfaces transceiver
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                     Optical   Optical
               Temperature  Voltage  Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (dBm)     (dBm)
    Gi1/0/26     25.2       3.31      -5.1     -28.5
    All SFP's are new as is the Multi Mode Fibre cable running from one building to another.

    Hi All,
    One of  member port of port channel was flapping and Here is the error message
    Error log:
    .Mar 17 08:27:37: %SFF8472-5-THRESHOLD_VIOLATION: Te6/1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -11.3 dBm.
    Cisco TAC analyse the issue under 629566213 but  their initial advices was not much experience oriented.
    Finally I have resolved the issue just by entering following command.
    switch 6 frulink reload
    Janaka Wellege Bsc.Eng
    University of Peradeniya.

  • SFF8472-3-THRESHOLD_VIOLATION on ME-3800X

    Hi All,
    Please see the logs below on Cisco ME-3800X, We are using IOS  "me380x-universalk9-mz.153-2.S.bin"
    %SFF8472-3-THRESHOLD_VIOLATION: Gi0/8: Rx power low warning; Operating value: -20.3 dBm, Threshold value: -19.0 dBm.
    is this bug ?anyone encounter this error ?
    Please help on this.
    Regards.

    Similar symptoms are in Cisco IOS Release 15.1(3)S5 but it was resolved
    CSCtu42387
    Symptoms: Gigabit and 10 Gigabit Fiber link reporting threshold violation alarm in Cisco ME3600, Cisco ME3800, and Cisco 7600 devices. The "%SFF8472-3-THRESHOLD_VIOLATION: Gi0/11: Rx power high alarm" error message is seen on ports.
    Conditions: This symptom is observed on Cisco ME3600, Cisco ME3800, and Cisco 7600 devices. The messages are seen with the interface shut or no shut.
    SFF8472-3-THRESHOLD_VIOLATION Gi5/1: Rx power low alarm; Operating value:
    -28.5 dBm, Threshold value: -24.0 dBm
    Workaround: Fixing the fiber signal issue or disconnecting the fiber from the transceiver has been known to stop the messages

  • SFF8472-5-THRESHOLD_VIOLATION ISSUE IN WS-C2960X-48TD-L SWITCH

    Hi,
    I am getting Rx power low warning message in cisco WS-C2960X-48TD-L SWITCH. we are using same cisco SFP module at both end.
    SFP Module Details:
    PID: SFP-10G-SR 
    Error Messages
    Apr 15 13:34:35.457: %SFF8472-5-THRESHOLD_VIOLATION: Te2/0/1: Rx power low warning; Operating value: -10.8 dBm, Threshold value:  -9.9 dBm.
    Apr 15 13:34:34.890: %SFF8472-5-THRESHOLD_VIOLATION: Te2/0/1: Rx power low warning; Operating value: -10.8 dBm, Threshold value:  -9.9 dBm. 
    Apr 15 13:44:37.217: %SFF8472-5-THRESHOLD_VIOLATION: Te2/0/1: Rx power low warning; Operating value: -10.6 dBm, Threshold value:  -9.9 dBm.
    Apr 15 13:44:36.647: %SFF8472-5-THRESHOLD_VIOLATION: Te2/0/1: Rx power low warning; Operating value: -10.7 dBm, Threshold value:  -9.9 dBm.
    Apr 15 13:54:38.988: %SFF8472-5-THRESHOLD_VIOLATION: Te2/0/1: Rx power low warning; Operating value: -11.0 dBm, Threshold value:  -9.9 dBm.
    Please tell me how can i fix this issues.
    Regards,
    Neeraj 

    Hello,
    I have same issues on our network on all non Cisco X2 modules starting on nearly the same day (devices have nearly same update). I can't say that it is only cosmetic nature due to the fact that after a lot of these messages happened I registered SPT topology changes. This happened on several of my devices but it is not very often. For our customers it is a two second hit, where services are not available. Our software is on the 15.0 release train so a lot of possibilities to upgrade to higher versions are not given at this time.
    Are in the above mentioned Cisco internal Bug (ID CSCth08212/CSCte94616) additional information which can be helpful but are not open to people outside TAC?
    With kind regards
    Stefan
    I forgot to mention that the message in my case describes a lot of temperature alerts (ranging from -130°C up to 130°C) that are violated and less of alerts belonging to the power.

  • CET: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Rx power high warning; Operating value: -0.9 dBm, Threshold value: -1.0 dBm.

    Hei
    we have some switches that are connected with our nexus switches via SFP-10GLR. all switches are ok but only one is getting warnings in the logs saying: CET: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Rx power high warning; Operating value:  -0.9 dBm, Threshold value:  -1.0 dBm.
    all the SFP,s are same in alle switches.

    %SFF8472-5-THRESHOLD_VIOLATION Vs SFF8472-5-THRESHOLD_VIOLATION.
    The first one is printed for the ports that are configured, but not connected/active.
    You can avoid such error messages simply shutting down unused ports.
    The latter indicates that there is a real threshold violation.
    For more details on these error messages, check out.
    http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/15.1/XE_330SG/system/messages/emsg.html#wp1634341
    Action Plan:
    ========
    Can you please try clearing the interface counters, so that we can notice the frequency of errors.
    Also I researched on the logs that we are observing on our device and have seen cases where the issue has been resolved by physically removing and reinserting transceiver.
    Please refer below link for more details:
    http://www.cisco.com/cgi-bin/Support/Errordecoder/index.cgi?action=search&counter=0&paging=5&links=reference&index=all&query=SFF8472-5-THRESHOLD_VIOLATION

  • Cat 4500 showing error %SFF8472-5-THRESHOLD_VIOLATION: Te3/1: Rx power low alarm

    Hello Friends,
    i have catalyst 4503 series switch and i am trying to configure it, there is not any physical media connected to the switch yet.
    but i have installed the X2-10GB-SM modules in its module (WS-X4606-X2-E)
    without any cable or connectivity with other switches.
    i am facing the error which is
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/1: Rx power low alarm; Operating value: -30.0 dBm, Threshold value: -18.4 dBm.
    *Jul 18 07:34:13.710: %SFF8472-5-THRESHOLD_VIOLATION: Te3/2: Rx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.9 dBm.
    *Jul 18 07:34:13.710: %SFF8472-5-THRESHOLD_VIOLATION: Te3/3: Rx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.9 dBm
    any idea to get off this problem?
    thanks

    Gents,
    Looks like something is amuck as I just received a new 4507 as well and I am getting similar messages. Anyone have an idea as to what is going on?  I too have not connected anything to this yet, just doing a burn in. I am installing into a cancer center and need to have this ready by the first.
    regards,
    Stephen
    Below is the info needed:
    CC-4507RE#sh mod
    Chassis Type : WS-C4507R+E
    Power consumed by backplane : 40 Watts
    Mod Ports Card Type                             Model             Serial No.
    ---+-----+--------------------------------------+------------------+-----------
    1   48 10/100/1000BaseT UPOE E Series         WS-X4748-UPOE+E   CAT1621L24P
    2   48 10/100/1000BaseT UPOE E Series         WS-X4748-UPOE+E   CAT1621L24M
    3     4 Sup 7-E 10GE (SFP+), 1000BaseX (SFP)   WS-X45-SUP7-E     CAT1617L5UY
    4     4 Sup 7-E 10GE (SFP+), 1000BaseX (SFP)   WS-X45-SUP7-E     CAT1619L1D3
    5   12 10GE SFP+                             WS-X4712-SFP+E     CAT1618L1LD
    M MAC addresses                   Hw Fw           Sw               Status
    --+--------------------------------+---+------------+----------------+---------
    1 a493.4c9f.a37c to a493.4c9f.a3ab 1.1                               Ok
    2 a493.4c9f.a43c to a493.4c9f.a46b 1.1                               Ok
    3 a493.4cd4.32c0 to a493.4cd4.32c3 2.1 15.0(1r)SG5 03.03.00.SG      Ok
    4 a493.4cd4.32c4 to a493.4cd4.32c7 2.1 15.0(1r)SG5 03.03.00.SG     Ok
    5 a493.4c55.6cb8 to a493.4c55.6cc3 1.1                               Ok
    Mod Redundancy role     Operating mode     Redundancy status
    ----+-------------------+-------------------+----------------------------------
    3   Active Supervisor   SSO                 Active
    4   Standby Supervisor SSO                 Standby hot
    ROM: 15.0(1r)SG5
    CC-4507RE uptime is 2 weeks, 5 hours, 47 minutes
    Uptime for this control processor is 2 weeks, 5 hours, 49 minutes
    System returned to ROM by power-on
    System image file is "bootflash:cat4500e-universalk9.SPA.03.03.00.SG.151-1.SG.bi
    n"
    Jawa Revision 7, Snowtrooper Revision 0x0.0x1C
    *Jul 20 07:24:07.884 UTC: %SFF8472-5-THRESHOLD_VIOLATION: Te3/1: Rx power low al
    arm; Operating value: -40.0 dBm, Threshold value:-12.4 dBm.
    *Jul 20 14:28:18.155 UTC: %SFF8472-5-THRESHOLD_VIOLATION: Te4/1: Rx power low ala
    rm; Operating value: -40.0 dBm, Threshold value: -12.4 dBm.

  • Optic power levels - %SFF8472-5-THRESHOLD_VIOLATION

    Can some explain this to me...
     %SFF8472-5-THRESHOLD_VIOLATION: Te1/0/1: Tx power low alarm
    If I am getting a LOW TX alert the issue can't be with the fibre and it has to be something do to with the optic / line card / software or chassis. I presume DOM is reporting this before the light is put onto the link... as in before it even touches the fibre.
    Any help is much appreciated.

    Hi
    It could be a bad transceiver.  Did you try reseating the transceiver once?
    If not helping please try replacing it and check.
    Thanks,
    M

  • SFF8472-5-THRESHOLD_VIOLATION

    Hello,
    I have a switch 3750X connected to a nexus 5000 via DWDM SFP (C3KX-NM-10G). The IOS of the 3750X is universalk9 12.2(58)SE2 and of the Nexus 5.2(1)N1(2a).
    I get all 10 seconds on the 3750x the following error:
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/1/2: Rx power high alarm; Operating value:  -1.7 dBm, Threshold value:  -6.0 dBm.
    When I add a buffer attenuator, nothing changed.
    Is this a bug of cisco or what can I do?
    BR
    Andreas

    Hello,
    I have a switch 3750X connected to a nexus 5000 via DWDM SFP (C3KX-NM-10G). The IOS of the 3750X is universalk9 12.2(58)SE2 and of the Nexus 5.2(1)N1(2a).
    I get all 10 seconds on the 3750x the following error:
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/1/2: Rx power high alarm; Operating value:  -1.7 dBm, Threshold value:  -6.0 dBm.
    When I add a buffer attenuator, nothing changed.
    Is this a bug of cisco or what can I do?
    BR
    Andreas

  • WS-X45-SUP8-E: %SFF8472-5-THRESHOLD_VIOLATION

    Hello,
    I got a WS-X45-SUP8-E Core switch with TenGigabitEthernet ports.
    one of the port on the core give the following error:
    %SFF8472-5-THRESHOLD_VIOLATION: Te5/4: Rx power low warning; Operating value: -12.4 dBm, Threshold value:  -9.9 dBm.
    The other switch connected on this link doesn't.
    It also doesn't seem like a Bug because the rest of the port are up and running just fine, same switches and SFP.
    I already changed the SFP and patch kabels.
    any ideas??
    Thanks.

    Hello,
    i changed the patches between 2 switches and now we got the error on a other switch. so the fiber between the core and access switches is giving the problems.
    in the on coming weeks where going to replace the fiber cable.
    MANY THANKS!!!

  • %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm

    Hi,
    I am facing a strange problem in one of my Cisco Catalyst 4900M switch. We have a ten gig WAN link which went down (error-disabled) couple of weeks back with logs suggesting Low TX power.
    Tried followingtroubleshooting approach, but it did not resolve the problem.
    SFP replaced
    Tried connecting the link on a different port.
    Fibers tested and found to be OK
    Performed loop test and was able to see the loop on both end of the P2P link.
    Replaced the Cables between PTT demarcation till switch patch panel.
    Switch Logs:
    IOS Version: bootflash:cat4500e-entservices-mz.150-2.SG1.bin
    Model: Cisco Catalyst 4900M
    *Jun 19 12:32:36.582: %PM-4-ERR_DISABLE: link-flap error detected on Te1/1, putting Te1/1 in err-disable state
    *Jun 19 12:34:04.154: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 12:44:04.254: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 12:54:04.354: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 13:04:04.454: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 13:14:04.558: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 13:24:04.658: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 13:34:04.761: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 13:44:04.861: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 13:54:04.961: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 14:04:05.061: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 14:14:05.161: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 14:24:05.261: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 14:34:05.361: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 14:44:05.461: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 14:54:05.561: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    *Jun 19 15:04:05.661: %SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -12.2 dBm.
    Switch1#
    Switch1#
    Switch1#
    Switch1#sh int te1/1
    TenGigabitEthernet1/1 is down, line protocol is down (err-disabled)
      Hardware is Ten Gigabit Ethernet Port, address is 2c54.2de6.5100 (bia 2c54.2de6.5100)
      Description: ***P2P ***
      MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec,
         reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA, loopback not set
      Keepalive set (10 sec)
      Full-duplex, 10Gb/s, link type is auto, media type is 10GBase-LR
      input flow-control is off, output flow-control is off
      ARP type: ARPA, ARP Timeout 04:00:00
      Last input 02:39:04, output never, output hang never
      Last clearing of "show interface" counters 2w0d
      Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0
      Queueing strategy: fifo
      Output queue: 0/40 (size/max)
      5 minute input rate 0 bits/sec, 0 packets/sec
      5 minute output rate 0 bits/sec, 0 packets/sec
         2367 packets input, 199072 bytes, 0 no buffer
         Received 2367 broadcasts (2367 multicasts)
         1 runts, 0 giants, 0 throttles
         5 input errors, 4 CRC, 0 frame, 0 overrun, 0 ignored
         0 input packets with dribble condition detected
         5951 packets output, 453948 bytes, 0 underruns
         0 output errors, 0 collisions, 13 interface resets
         0 babbles, 0 late collision, 0 deferred
         0 lost carrier, 0 no carrier
         0 output buffer failures, 0 output buffers swapped out
    Switch1#
    Switch1#sh int te1/1 transceiver detail
    ITU Channel not available (Wavelength not available),
    Transceiver is internally calibrated.
    mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    A2D readouts (if they differ), are reported in parentheses.
    The threshold values are calibrated.
                                  High Alarm  High Warn  Low Warn   Low Alarm
              Temperature         Threshold   Threshold  Threshold  Threshold
    Port       (Celsius)          (Celsius)   (Celsius)  (Celsius)  (Celsius)
    Te1/1       30.7                74.0        70.0         0.0       -4.0
                                  High Alarm  High Warn  Low Warn   Low Alarm
               Voltage            Threshold   Threshold  Threshold  Threshold
    Port       (Volts)            (Volts)     (Volts)    (Volts)    (Volts)
    Te1/1      0.00                   N/A         N/A         N/A        N/A
               Optical            High Alarm  High Warn  Low Warn   Low Alarm
               Transmit Power     Threshold   Threshold  Threshold  Threshold
    Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
    Te1/1      -40.0                 4.4         0.4        -8.2      -12.2
               Optical            High Alarm  High Warn  Low Warn   Low Alarm
               Receive Power      Threshold   Threshold  Threshold  Threshold
    Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
    Te1/1      -12.3                 4.4         0.4       -14.4      -18.4

    I did replace the SFP with a new one.
    Interface Te1/2 is up and working.
    SESK_P2P10G-4900MSOD-SW1#sh int te1/2 transceiver de
    ITU Channel not available (Wavelength not available),
    Transceiver is internally calibrated.
    mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    A2D readouts (if they differ), are reported in parentheses.
    The threshold values are calibrated.
                                  High Alarm  High Warn  Low Warn   Low Alarm
              Temperature         Threshold   Threshold  Threshold  Threshold
    Port       (Celsius)          (Celsius)   (Celsius)  (Celsius)  (Celsius)
    Te1/2       34.6                74.0        70.0         0.0       -4.0
                                  High Alarm  High Warn  Low Warn   Low Alarm
               Voltage            Threshold   Threshold  Threshold  Threshold
    Port       (Volts)            (Volts)     (Volts)    (Volts)    (Volts)
    Te1/2      3.22                   N/A         N/A         N/A        N/A
               Optical            High Alarm  High Warn  Low Warn   Low Alarm
               Transmit Power     Threshold   Threshold  Threshold  Threshold
    Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
    Te1/2       -1.5                 4.4         0.4        -8.2      -12.2
               Optical            High Alarm  High Warn  Low Warn   Low Alarm
               Receive Power      Threshold   Threshold  Threshold  Threshold
    Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
    Te1/2       -3.6                 4.4         0.4       -14.4      -18.4

  • Threshold violation on Portchannel

    I created port channel between 3750 ME and 3750-X, using MM fiber, but getting an error message
    %SFF8472-5-THRESHOLD_VIOLATION: Gi2/1/1: Rx power high warning; Operating value:  -1.6 dBm, Threshold value:  -3.0 dBm.
    *Mar  1 00:12:11.318: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/1/1: Rx power high warning; Operating value:  -1.5 dBm, Threshold value:  -3.0 dBm. (NWP-TEST-3750-X-1)
    *Mar  1 00:12:15.135: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/1/1: Rx power high war
    Please suggest how can I fix this
    Thanks

    Hello.
    Try to replace SFP module and fiber cable.
    Please provide "show int trans de" from both sides.
    What is the length (and type) of fiber cable you are using?

  • Threshold_Violation error messages

    Hi guys,
    I recently noticed company core switch cisco 4507 generating the below error messages from the 10gig module.
    *Jan 28 22:16:10.752: %SFF8472-5-THRESHOLD_VIOLATION: Te3/2: Rx  power low alarm; Operating value: -12.7 dBm, Threshold value: -12.4 dBm.
    *Jan 28 22:16:03.004: %SFF8472-5-THRESHOLD_VIOLATION: Te7/2: Rx  power low warning; Operating value: -10.4 dBm, Threshold value:  -8.4  dBm.
    Interface ten3/2 is interconnecting another 4507 within the same network cabinet.
    Interface ten7/2 is interconnecting a different site distribution switch that is 400meters away.
    Anyone who can assist.???

    thanks Ankur,
    Below is the output of sh commands,
    CORE1#sh int ten3/2 transceiver detail
    ITU Channel not available (Wavelength not available),
    Transceiver is internally calibrated.
    mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    A2D readouts (if they differ), are reported in parentheses.
    The threshold values are calibrated.
                                  High Alarm  High Warn  Low Warn   Low Alarm
              Temperature         Threshold   Threshold  Threshold  Threshold
    Port       (Celsius)          (Celsius)   (Celsius)  (Celsius)  (Celsius)
    Te3/2       28.1                74.0        70.0         0.0       -4.0
                                  High Alarm  High Warn  Low Warn   Low Alarm
               Voltage            Threshold   Threshold  Threshold  Threshold
    Port       (Volts)            (Volts)     (Volts)    (Volts)    (Volts)
    Te3/2      0.00                   N/A         N/A         N/A        N/A
               Optical            High Alarm  High Warn  Low Warn   Low Alarm
               Transmit Power     Threshold   Threshold  Threshold  Threshold
    Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
    Te3/2       -2.5                 2.9         0.4        -6.5      -10.5
               Optical            High Alarm  High Warn  Low Warn   Low Alarm
               Receive Power      Threshold   Threshold  Threshold  Threshold
    Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
    Te3/2      -12.7                 2.9         0.4        -8.4      -12.4
    CORE1#
    CORE1#sh int ten7/2 transceiver detail
    ITU Channel not available (Wavelength not available),
    Transceiver is internally calibrated.
    mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    A2D readouts (if they differ), are reported in parentheses.
    The threshold values are calibrated.
                                  High Alarm  High Warn  Low Warn   Low Alarm
              Temperature         Threshold   Threshold  Threshold  Threshold
    Port       (Celsius)          (Celsius)   (Celsius)  (Celsius)  (Celsius)
    Te7/2       32.8                74.0        70.0         0.0       -4.0
                                  High Alarm  High Warn  Low Warn   Low Alarm
               Voltage            Threshold   Threshold  Threshold  Threshold
    Port       (Volts)            (Volts)     (Volts)    (Volts)    (Volts)
    Te7/2      3.27                   N/A         N/A         N/A        N/A
               Optical            High Alarm  High Warn  Low Warn   Low Alarm
               Transmit Power     Threshold   Threshold  Threshold  Threshold
    Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
    Te7/2       -2.1                 2.9         0.4        -6.5      -10.5
               Optical            High Alarm  High Warn  Low Warn   Low Alarm
               Receive Power      Threshold   Threshold  Threshold  Threshold
    Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
    Te7/2      -10.5                 2.9         0.4        -8.4      -12.4
    #sh idprom int ten3/2
    X2 Serial EEPROM Contents:
    Non-Volatile Register (NVR) Fields
    X2 Version                           :0x1E = MSA Version 0x1E
    NVR Size in bytes                    :0x100
    Number of bytes used                 :0x100
    Basic Field Address                  :0xB
    Customer Field Address               :0x77
    Vendor Field Address                 :0xA7
    Extended Vendor Field Address        :0x100
    Reserved                             :0x0
    Transceiver type                     :0x2 =X2
    Optical connector type               :0x1 =SC
    Bit encoding                         :0x1 =NRZ
    Normal BitRate in multiple of 1M b/s :0x2848
    Protocol Type                        :0x1 =10GbE
    Standards Compliance Codes :
    10GbE Code Byte 0                    :0x0 =10GBase-LRM
    10GbE Code Byte 1                    :0x0
    SONET/SDH Code Byte 0                :0x0
    SONET/SDH Code Byte 1                :0x0
    SONET/SDH Code Byte 2                :0x0
    SONET/SDH Code Byte 3                :0x0
    10GFC Code Byte 0                    :0x0
    10GFC Code Byte 1                    :0x0
    10GFC Code Byte 2                    :0x0
    10GFC Code Byte 3                    :0x0
    Transmission range in 10m            :0x16
    Fibre Type :
    Fibre Type Byte 0                    :0x1 =MM, Generic
    Fibre Type Byte 1                    :0x0 =Unspecified
    Centre Optical Wavelength in 0.01nm steps - Channel 0 :0x1 0xFF 0xB8
    Centre Optical Wavelength in 0.01nm steps - Channel 1 :0x0 0x0 0x0
    Centre Optical Wavelength in 0.01nm steps - Channel 2 :0x0 0x0 0x0
    Centre Optical Wavelength in 0.01nm steps - Channel 3 :0x0 0x0 0x0
    Package Identifier OUI  :0xC09BE0
    Transceiver Vendor OUI  :0x3E800
    Transceiver vendor name :CISCO-EXCELIGHT
    Part number provided by transceiver vendor       :SDX4101LM-C1-M
    Revision level of part number provided by vendor
    Vendor serial number           :ECL131600C3
    Vendor manufacturing date code :200904274H
    Current Reference :
    5V Stressed Environment Reference 100 percent=1A   :0x0
    3.3V Stressed Environment Reference 100 percent=2A :0x4
    APS Stressed Environment Reference 100 percent=2A  :0x2
    Normal APS Voltage :0x4
    Digital Optical Monitoring Capability Byte  :0xC7
    Digital Optical Monitoring                  :Implemented
    Low Power Start-up(LPS) Mode Capability Bit :0x1
    Reserved             :0x0
    Basic Field Checksum :0x23
    Customer Writable Area :
      0x00: 58 32 2D 31 30 47 42 2D 4C 52 4D 20 20 20 20 20
      0x10: 20 56 30 31 20 45 43 4C 31 33 31 36 30 30 43 33
      0x20: 31 30 2D 32 33 36 38 2D 30 31 20 20 41 30 20 20
    Vendor Specific :
      0x00: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
      0x10: 00 00 00 00 00 00 00 00 00 8A 33 13 43 00 00 00
      0x20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
      0x30: 00 00 02 00 0B 5F C2 DB 77 84 26 70 B7 35 04 D1
      0x40: 39 7C 79 54 98 00 00 00 00 00 00 00 00 00 48 D5
      0x50: 90 7C 15 DB 11 9D 00 CC 20
    CORE1#
    CORE1#sh idprom int ten7/2
    X2 Serial EEPROM Contents:
    Non-Volatile Register (NVR) Fields
    X2 Version                           :0x1E = MSA Version 0x1E
    NVR Size in bytes                    :0x100
    Number of bytes used                 :0x100
    Basic Field Address                  :0xB
    Customer Field Address               :0x77
    Vendor Field Address                 :0xA7
    Extended Vendor Field Address        :0x100
    Reserved                             :0x0
    Transceiver type                     :0x2 =X2
    Optical connector type               :0x1 =SC
    Bit encoding                         :0x1 =NRZ
    Normal BitRate in multiple of 1M b/s :0x2848
    Protocol Type                        :0x1 =10GbE
    Standards Compliance Codes :
    10GbE Code Byte 0                    :0x0 =10GBase-LRM
    10GbE Code Byte 1                    :0x0
    SONET/SDH Code Byte 0                :0x0
    SONET/SDH Code Byte 1                :0x0
    SONET/SDH Code Byte 2                :0x0
    SONET/SDH Code Byte 3                :0x0
    10GFC Code Byte 0                    :0x0
    10GFC Code Byte 1                    :0x0
    10GFC Code Byte 2                    :0x0
    10GFC Code Byte 3                    :0x0
    Transmission range in 10m            :0x16
    Fibre Type :
    Fibre Type Byte 0                    :0x1 =MM, Generic
    Fibre Type Byte 1                    :0x0 =Unspecified
    Centre Optical Wavelength in 0.01nm steps - Channel 0 :0x1 0xFF 0xB8
    Centre Optical Wavelength in 0.01nm steps - Channel 1 :0x0 0x0 0x0
    Centre Optical Wavelength in 0.01nm steps - Channel 2 :0x0 0x0 0x0
    Centre Optical Wavelength in 0.01nm steps - Channel 3 :0x0 0x0 0x0
    Package Identifier OUI  :0xC09820
    Transceiver Vendor OUI  :0x3400A80
    Transceiver vendor name :CISCO-OPNEXT,INC
    Part number provided by transceiver vendor       :TRT5002EN-SMC-6
    Revision level of part number provided by vendor :A1
    Vendor serial number           :OPB17350162
    Vendor manufacturing date code :2013091900
    Current Reference :
    5V Stressed Environment Reference 100 percent=1A   :0x0
    3.3V Stressed Environment Reference 100 percent=2A :0x1
    APS Stressed Environment Reference 100 percent=2A  :0x10
    Normal APS Voltage :0x4
    Digital Optical Monitoring Capability Byte  :0xD7
    Digital Optical Monitoring                  :Implemented
    Low Power Start-up(LPS) Mode Capability Bit :0x1
    Reserved             :0x0
    Basic Field Checksum :0xAE
    Customer Writable Area :
      0x00: 58 32 2D 31 30 47 42 2D 4C 52 4D 20 20 20 20 20
      0x10: 20 56 30 34 20 4F 50 42 31 37 33 35 30 31 36 32
      0x20: 31 30 2D 32 33 36 38 2D 30 34 20 20 41 30 20 20
    Vendor Specific :
      0x00: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
      0x10: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
      0x20: FF FF FF FF FF FF FF FF FF 00 AA 00 A0 FF FF FF
      0x30: FF FF 02 00 11 AB 00 9B 52 D4 A1 C6 DC 79 90 A3
      0x40: 18 A9 77 2C 87 00 00 00 00 00 00 00 00 00 A1 39
      0x50: B9 6D 17 52 0D F0 27 10 FF

  • I am getting the following error messages:

    I am getting the following error messages:
    May 29 15:31:42.404 utc: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/1: Rx power high warning; Operating value:  -2.0 dBm, Threshold value:  -3.0 dBm.
    May 29 15:41:42.974 utc: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/1: Rx power high warning; Operating value:  -2.0 dBm, Threshold value:  -3.0 dBm.
    What is the solution?

    Hi,
    From the error decoder
    Showing 1-3 of 3 results 
    Page:               1               
    1. %SFF8472-5-THRESHOLD_VIOLATION: [char]: [char]; Operating value: [char]There was a threshold violation as specified in the message.
    Recommended Action: Contact your technical support representative.
    Related documents- No specific documents apply to this error message. 
    2. %SFF8472-5-THRESHOLD_VIOLATION: [char]: [char]; Operating value: [char]There has been a threshold violation as specified in the message.
    Recommended Action: Make sure that the port is active. If port does not need to be active, then transceiver ought to be removed. If port should be active, but is not, then make sure that the connection is appropriate. Sometimes, removing and reinserting transceiver might help. For all other issues, please contact technical support.
    Related documents- No specific documents apply to this error message. 
    3. %SFF8472-5-THRESHOLD_VIOLATION: [char]: [char]; Operating value: [char], Threshold value: [char].The specified port is not connected, or it is connected to a damaged fiber optic cable.
    Recommended Action: If the message relates to an enabled but unconnected DOM transceiver, shut the port to stop the alarm messages. If the alarm persists, or relates to an enabled and connected transceiver, contact your Cisco technical support representative.
    Related documents- No specific documents apply to this error message. 
    Hope this helps
    Regards
    Alex

  • Warning message about Rx power high on Catalyst 4900M

    We get the following warning messages in the log on our 4900M:
    Dec 12 09:21:37.367 EST: %SFF8472-5-THRESHOLD_VIOLATION: Te3/8: Rx power low warning; Operating value: -12.1 dBm, Threshold value:  -9.9 dBm.
    Dec 12 09:31:37.537 EST: %SFF8472-5-THRESHOLD_VIOLATION: Te3/8: Rx power low warning; Operating value: -12.1 dBm, Threshold value:  -9.9 dBm.
    the 4900M is connected to a 3560E at port Te0/2. No violations are reported on the 3560E.
    We have already replaced modules on both the 4900M and the 3560E. We also replaced the fiber patch cables, and moved the patch cables to connect to a backup set of fiber cables.
    Additional logs:
    4900M#show interfaces transceiver module 3
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                     Optical   Optical
               Temperature  Voltage  Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (dBm)     (dBm)
    Te3/5        33.2       0.00      -2.1      -3.1   
    Te3/6        31.9       0.00      -1.6      -3.0   
    Te3/7        30.3       3.22      -2.3      -2.4   
    Te3/8        29.7       3.23      -2.2     -12.1   
    3560E#show interfaces transceiver module 1
    Transceiver monitoring is disabled for all interfaces.
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                               Optical   Optical
               Temperature  Voltage  Current   Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (mA)      (dBm)     (dBm)
    Te0/1        32.0       0.00       8.1      -2.1      -2.0   
    Te0/2        31.2       0.00       1.2      -2.6      -3.9  
    We are unsure what else the issue could be. Any ideas would be appreciated.

    Can you provide more detail as to what is in the link between the 4900M and the 3560E? 
    4900M --- patch cord --- bulkhead panel ---- ? backbone cable ? ---- bulkhead panel --- patch cord --- 3560E
    Do you know if there are any other connectors or splices in the network?  How many fibers are in the backbone cable?  Which transceiver are you using?  

  • Warning message about Rx power high on Catalyst 4500E

    Hi,
    The following messages are logged in the irregular on Catalyst 4500E Supervisor Engine 7-E.
    Are these fiber links required the attenuators?
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.5 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.9 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.6 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.9 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.6 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.9 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.6 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.8 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te2/6: Rx power high warning; Operating value:   0.5 dBm, Threshold value:   0.4 dBm.
    %SFF8472-5-THRESHOLD_VIOLATION: Te3/6: Rx power high warning; Operating value:   0.9 dBm, Threshold value:   0.4 dBm.
    Thank you for your cooperation in advance.
    -------- Additional Logs Start --------
    Cat45E+Sup7E#show interfaces Te2/6 | inc media type
      Full-duplex, 10Gb/s, link type is auto, media type is 10GBase-LR
    Cat45E+Sup7E#show interfaces Te3/6 | inc media type
      Full-duplex, 10Gb/s, link type is auto, media type is 10GBase-LR
    Cat45E+Sup7E#show interfaces transceiver module 2
    Load for five secs: 5%/1%; one minute: 6%; five minutes: 6%
    Time source is NTP, 13:29:28.720 JST Tue Feb 19 2013
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                     Optical   Optical
               Temperature  Voltage  Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (dBm)     (dBm)
    Te2/1        35.6       3.26      -1.6      -0.2
    Te2/2        37.0       3.26      -1.7      -0.3
    Te2/3        35.1       3.27      -2.6      -2.2
    Te2/4        36.7       3.28      -2.5      -2.5
    Te2/5        35.6       3.25      -1.3      -0.9
    Te2/6        35.0       3.26      -1.7       0.6
    Te2/7        36.1       3.28      -2.4      -2.8
    Te2/8        35.1       3.28      -2.4      -3.0
    Te2/9        33.1       3.23      -2.4      -2.4
    Te2/10       32.2       3.32      -2.1      -3.0
    Te2/11       35.0       3.25      -2.5      -2.9
    Cat45E+Sup7E#show interfaces transceiver module 3
    Load for five secs: 6%/2%; one minute: 6%; five minutes: 6%
    Time source is NTP, 13:29:44.348 JST Tue Feb 19 2013
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                     Optical   Optical
               Temperature  Voltage  Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (dBm)     (dBm)
    Te3/1        36.2       3.26      -2.1       0.2
    Te3/2        35.6       3.26      -1.7      -0.6
    Te3/3        36.8       3.26      -2.4      -3.4
    Te3/4        36.8       3.28      -2.5      -2.6
    Te3/5        35.2       3.26      -1.3       0.0
    Te3/6        36.2       3.26      -1.1       0.9
    Te3/7        34.2       3.28      -2.4      -2.8
    Te3/8        34.0       3.29      -2.0      -3.1
    Te3/9        35.4       3.28      -2.5      -2.3
    Te3/10       32.5       3.24      -2.4      -4.2
    Te3/11       34.2       3.28      -2.4      -3.2
    Cat45E+Sup7E#show interfaces transceiver threshold-table
    Load for five secs: 7%/3%; one minute: 6%; five minutes: 6%
    Time source is NTP, 13:29:52.304 JST Tue Feb 19 2013
                  Optical Tx     Optical Rx    Temp     Laser Bias    Voltage
                                                        current
    10GE LR SFP+
    Min1            -12.20        -18.40        -5            N/A          3.00
    Min2             -8.20        -14.40        0             N/A          3.10
    Max2              0.50          0.50        70            N/A          3.50
    Max1              3.50          3.50        75            N/A          3.60
    -------- Additional Logs End --------

    Hello Marivin.
    I am configured new WS-C4500X-32 switches for distribution layer and server aggreation WS-C3650-48TQ-E with these model.
    I am geetting below error message. I read your document but i ham getting here low alaram, i have observed because of this i am loosing connectiy with my neibhor device and ehter channel is flapping.
    Kindly help me to fix this....
    *Jan 28 23:54:04.417: %SFF8472-5-THRESHOLD_VIOLATION: Te1/29: Rx power low alarm; Operating value: -16.4 dBm, Threshold value: -13.9 dBm.
    *Jan 28 23:54:07.317: %SFF8472-5-THRESHOLD_VIOLATION: Te1/31: Rx power low warning; Operating value: -10.5 dBm, Threshold value:  -9.9 dBm.
    *Jan 28 23:54:07.417: %SFF8472-5-THRESHOLD_VIOLATION: Te1/32: Rx power low warning; Operating value: -11.4 dBm, Threshold value:  -9.9 dBm.

Maybe you are looking for

  • Unable to see master data changes

    I added a new field as an Attribute to Master Data (Customer Number) and loaded the data which was successfull. I created an infoset and created a report but am unable to see the values in this new field. I check 'Values in the Infoprovider' on the r

  • Problems in using Windows Explorer with VPC Virtual PC?

    Has anybody experienced problems in using Windows Explorer with VPC Virtual PC? Lacking any "forbidden" or "appropriate usage" guidelines, I regularly use Windows Explorer (Windows 2000) to transfer file from the desktop. I have occasionally sensed t

  • IBook G3 Mac OS 9 Problems

    I bought an old iBook G3 laptop computer from someone on ebay and there's a few problems. The hard drive had less space than advertised so I bought an internal hard drive and my uncle installed it for me. That hard drive had 9.2.2 installed on it but

  • Inability to assign freight vendor at header condition level

    Hello all We are working on ECC 5.0 but will shortly be moving to ECC 6.0. We have a scenario where raw materials are purchased from one vendor and delivered by a freight carrier (for which we are liable). To satisfy a Finance requirement to capture

  • BT Hub phone - Query

    My hub phone fails to record my calls in the menu lists The following menus in the calls list all show "empty" despite having made, received or missed calls. The phone will tell me I have missed acalls but the calls list menu still shows "empty" Can