Multisim simulation error

I am encountering an error while simulating AD636, ADG407 and AD623. I even tried to use ADI Multisim AD Edition but still receiving the same type of error.  These multisim symbols are downloaded from Analog Devices website.
I have provided the following links to gain access to the error log files and screen capture of the circuit.
AD636 simulation error, multisim failed to resolve the problem using convergence assistant:
http://www.engineers.auckland.ac.nz/~htar006/error/ad636/capture.jpg
http://www.engineers.auckland.ac.nz/~htar006/error/ad636/Circuit2.ms10
http://www.engineers.auckland.ac.nz/~htar006/error/ad636/simulation_log_file.log
ADG407 simulation error, also multisim failed to resolve the problem using convergence assistant:
http://www.engineers.auckland.ac.nz/~htar006/error/adg407/capture.jpg
http://www.engineers.auckland.ac.nz/~htar006/error/adg407/Circuit1.ms10
http://www.engineers.auckland.ac.nz/~htar006/error/adg407/simulation_log.log
AD626 output is clipped operating in single supply mode and biased in the middle of the supply voltage:
http://www.engineers.auckland.ac.nz/~htar006/error/ad626/capture.jpg
http://www.engineers.auckland.ac.nz/~htar006/error/ad626/Circuit4.ms10
and for the AD623
http://www.engineers.auckland.ac.nz/~htar006/error/ad623/capture.jpg
http://www.engineers.auckland.ac.nz/~htar006/error/ad623/Circuit6.ms10
http://www.engineers.auckland.ac.nz/~htar006/error/ad623/simulation_log.log
I hope anyone can help me clear out the problem.
Regards,
Harold
Attachments:
error.zip ‏993 KB

Hi Harold,
Circuit 2
Please use the attached model.  The sqrt function is causing a problem with the current SPICE engine, you can replace sqrt with pwr () function and the model should behave the same.
Circuit 1.
You need to add a semi colon to indicate comment on the line shown below.  Double click on the component and select Edit Model
R_VB_C     422 500 1E6             components on these nodes
Circuit 4. 
I believe this is a model issue.  There are many models that were not designed to work single power supply and I believe is the case here.
Circuit 6. 
I ran the circuit in ADI edition and also 10.0.1 and was not able to replicate the simulation error.
Tien P.
National Instruments
Attachments:
AD636.txt ‏4 KB

Similar Messages

  • Multisim simulation error voltage

    I am evaluating Multisim11 with this circuit.  I was thinking of the LM317, but the LM117 was in the library.  It looks like it simulates adequately when the switch is on, but not when it is off (23KV from a 24V supply).  What am I doing wrong?  Thanks.
    Attachments:
    Design1.ms11 ‏67 KB
    test.jpg ‏51 KB

    Hi mstepp,
    I have attached the modified circuit to this post. You can right-click the LM117H and select Save Component to DB. Then you can add this component to your user database. As far as the transistor goes, the simulation models for all the components are developed by the manufacturers so they usually try to make them as realistic as possible. If there is more than one simulation model available, they are shown on the bottom right under Model manufacturer/ID in the Select a Component Window. You can try different models if available.
    Hope this helps.
    Regards,
    Tayyab R,
    National Instruments.
    Attachments:
    Design1 voltage issue mod.ms11 ‏71 KB

  • Capacitor simulation error

     Hi; I Have an problem;
    When simulating  "time step too small " often occurs;  After Using Convergence Assistant; I can simulate but the output of XSC1 is not corrent , It include direct flow,
    The capacitor C1 not filter dirent flow. and in "alteractive simulation settings" ->"initial conditions" is changed from "Automatically ..." to "user defined"
    If I change from "user defined " to "Automatically ...", when simulating the simulation error dialog occurs.  the multisim version is 10.0 

    Avoid re-build the circuit map, I post the circuit map directly. 
    summarize:  "interactive simulation settings" -> "set to zero"     result:     output have direct flow.
                        "interactive simulation settings" -> "user define"     result:     output have direct flow.
                        "interactive simulation settings" -> "DC operating ..."     result:     simulation error occurs: time step too small
                        "interactive simulation settings" -> "Automatically ..."     result:     simulation error occurs: time step too small
    Would you like to explain the role of "time step" in multisim?
    Thank you! 
    Attachments:
    bjt_time_too_small.zip ‏68 KB

  • How to solve simulation error

    Hi,
    I am new out here,so need your help with a few things.
    I am continuously getting a simulation error with almost every circuit i am implementing. It runs the convergence assistant but it couldn't reproduce the error for any of my circuits so didn't help.
    Is there any tutorial available or any website which helps out on how to design to remove such errors or steps to rectify them ?
    regards,
    S!D 

    Hi S!D;
    Since you don't give much information on the error you're obtaining I can think of two common issues, the first one is that Multisim is searching for an unexisting folder and the second one is an issue regarding the power inputs of your circuits. I attach two links to documents that can help you solve either one of the issues I mentioned, but if you get a different error from the ones I've told you, could you send more information regarding the error you obtain?
    http://digital.ni.com/public.nsf/allkb/221393F998C08491862571ED0077FCC3?OpenDocument
    http://digital.ni.com/public.nsf/allkb/15526EB2464F3EDD8625722C00696BB0?OpenDocument
    Hope the information is useful.
    Good luck
    Francisco Arellano
    National Instruments Mexico
    Field Systems Engineer - Energy Segment
    www.ni.com/soporte

  • Constant Simulation Errors

    Hey everyone
    I have been trying to make a rather simple relay control timing circuit and I keep running into errors when I flip the trigger swithch. I get a simulation error that wants me to run a convergence check. When I run the check, it will not find anything. Even when simulating just a part of the circuit, or removing components in case it is a Spice error, I still get this error coming back. It only stops when I turn off the 5v supply. I then tried to provide a seperate 5v supply, but the error comes back. Anyone have ideas what is going on? I ran an electrical check and the errors it gives me do not make sense for the components I am using.
    The circuit is attached.
    Thanks
    Attachments:
    CircDesignLEEFI.ms12 ‏225 KB

    Hi,
    You can go to Simulate -> Interactive Simulation Settings. Change the Intial conditions drop down menu to "Set to zero". Then run the simulation. It does not seem to be giving an error after this. Check the output of your circuit to make sure if you are seeing what you expect.
    Hope this helps.
    Regards,
    Tayyab R,
    National Instruments.

  • Long simulation errors

    Hi,
    I have some long simulations to run and to get realistic resuilts I need to keep the timestep small.
    I am getting simulation failures with 'internal simulation error'.
    If I remove some variables it can go longer.
    After the failure if I open the grapher it tries to graph the data but halts and restarts every 6-8 seconds and starts over -forever.  Each try it is able to plot some varying amount of the data.  The data is very good with the small timestep as opposed to longer timesteps, but it does not seem MS12 can handle the amoun tof data.
    What are the limitations?  How many samples of how many variables can I accumulate and still have the simulation and grapher work?
    Thanks.

    I tried the recorder, but is seems to only take up to four signals.  It also hangs MS after closing the configuration panel.
    I have had better luck just saving a segment of the data I want.  i.e. I run a 50msec simulation but the first 40 msec is start up activity.  I tell MS to simulate 40-45 msec, and though it simulates the full interval it only stores the segment of data requested.  The grapher can then handle that.  At least it could until I tried to turn on sample display.  Then it never recovered and I had to kill MS and lost my overnight simulation data. :-(
    The fine timestep simulation data is vastly more accurate than default timesteps or other values suggested in the forums.
    I should think there should be a simulation option that forces finer timesteps when signals are active and stretches them out when static.  If I just set the simulation tolerances tighter does this do that?
    Thanks,
    David B

  • Multisim 13 error?

    I am simulating a simple circuit.
    One of my nets shows on the 4 channel oscilloscope the expected values: going from -20V on 71 us to +20V on 96 us.
    The bahaviour of the circuit does not reflect this.
    After searching I put multimeters on the same net.
    On 71 us  this showed -17V and on 96 us -12V.
    This looks to me a simulation error.
    Note that after many simulation errors (stops) I had to put the parameters at
    ABSTOL 1E-6 VNTOL 1E-3 RELTOL 1E-2 RSHUNT 1e*8 and max transient iterations at 500.
    Thanks for any comments
    Attachments:
    Schermafdruk 2014-07-28 10.51.21.png ‏143 KB
    Schermafdruk 2014-07-28 11.06.50.png ‏201 KB
    test1.ms13 ‏426 KB

    Thank you Thierry,
    The model is attached. I changed hierarchical blocks to subcircuits, I hope this makes sure it is complete.
    A confidential part of the main circuit has been removed, but the error still shows up, also with the inputs of the LM293D now within spec.
    In the first screenprint you see that net C1_active, attached to connector ON is 0V on oscilloscope XSC7, T2, and 10.233V on multimeter XMM1.
    In the second screenprint it is 20V on XSC7, T1, and 10V on XMM1.
    In case you look into it, please note that my other comment about a possible error in the model for LM293D (no open collector output) is also demonstrated in this model.
    Kind Regards,
    Jan
    Attachments:
    Schermafdruk 2014-07-29 10.09.11.png ‏130 KB
    Schermafdruk 2014-07-29 10.09.55.png ‏129 KB
    test.ms13 ‏426 KB

  • Multisim simulation not working

    Hi
    I'm a newbie at multisim.
    I would like to ask any one out there for help. After I have built up a project and I click on simulate in mul;tisim nothing happens yet the same project works like a dream under proteus.
    My question is is there a setting that needs to be activated or setup so as to be able to run simulation under Multisim.
    Or is there a specific way of getting projects to work in multisim.
    Please help me if any one can as i prefer multisim over proteus.
    thanks in advance
    Ernest

    Hi Tien P
    Thank you for replying to my post much appreciated.
    At the moment im trying to get a running message to work as well as a digital clock i have checked all connections countless times and they are as the schematic diagram has given them
    but when i execute the project nothing happens and no i dont get any error messages. So i'm assuming all is well but no message scrolls or no time is displayed. I dont know much about programing so i cant see if the fault is maybe there.
    Thanks Again
    Ernest

  • Simulation error message

    Hi,
    I really need you help. I've bought a book with a Multisim 10.1 Student Edition.
    When I want to simulate something, I receive the following error message:
    "This circuit has no power sources: unable to determine the simulation timestep automatically.
    Please add a power source or set the simulation timestep under "Interactive Simulation Settings" to proceed."
    I am using Windows XP.
    Some time before I downloaded Evaluation Version from NI website and had the same problem.
    Thank you for your help.
    Best,
    Anis

    Hi,
    Just as Johann explains, you need to set a VCC and GND on your schematic so the digital components can work correctly, here's a link to a document that has a more detailed explanation on why you need them and how to connect them.
    http://digital.ni.com/public.nsf/allkb/221393F998C08491862571ED0077FCC3?OpenDocument
    Hope the information is useful.
    Good Luck
    Francisco Arellano
    National Instruments Mexico
    Field Systems Engineer - Energy Segment
    www.ni.com/soporte

  • MCU Simulation Error

    Hello!
    I'm just used Multisim 10 Evaluation Version. I got a problem with the simulation of Microcontroller Unit, the PIC16F84A. I got a circuit, and try to simulated it with my assembly source file. But when I try to simulate it I got an error of:
    Multisim  -  2007-05-11 21:21:41
    ----------------------------Building: Project: act3-----------------------------
    interupt.asm
    Note: Due to path length limitations in the Microchip MPASM for PIC16, the path D:\National.Instruments.Circuit.Design.Suite.v10.0​.Power.Pro\interrupt\interrupt\interrupt\act3\ has been mapped to the drive Z: temporarily for this operation.
    Error: Unable to run assembler.
    How can I fix this? What are the settings before running a MCU simulation?
    I've attached my circuit below.
    Thank you.
    Message Edited by hala_oi on 05-11-2007 08:31 AM
    Message Edited by hala_oi on 05-11-2007 08:45 AM
    Attachments:
    inter.jpg ‏67 KB
    inter.jpg ‏67 KB

    Hi CheValier,
    I just found out that the MCU compiler does not simulate on Vista or a 64 bit OS and you will get this message:
    D:\National.Instruments.Circuit.Design.Suite.v10.0​.Power.Pro\interrupt\interrupt\interrupt\act3\ has been mapped to the drive Z: temporarily for this operation.
    Error: Unable to run assembler.
    I know that R&D have fixed this issue and will likely be available in future release.
    Tien
    Message Edited by Tien P on 05-31-2007 10:01 AM
    Tien P.
    National Instruments

  • Trip simulation error in WD ABAP

    Hi SDNers,
    We are using WD ABAP based travel management via ESS/MSS with EP 7.0 ECC 6.0 EhP4 landscape.
    We are trying to raise a travel request for various employees (pernrs), it gives the following error message.
    Trip can not be saved due to errors in simulation  Display Help
    Entry not found in table T706V. Argument: SCP AIN 1A 0031620100419
    We have maintained cost cetre details in Infotype 17, 27, 0001, maintianed the entries in above view (V_T706V) for India country gruping.
    Still gives the same error messages for various employees.
    However, the trip is successfully recorded in trip, pr05 tcodes.
    Please suggest the way forward, we are stcuk with this issue from past two days.
    Regards,
    Anil Kumar

    V_T706V is the perdiem table. Make sure that you have configured properly in this table.

  • Vendor & customer invoice posting.....while simulating  -- error ?...

    Dear,
       While posting vendor and customer Invoice----
          When Invoice date and posting date has given as xx.xx.xxxx with fiscal year xx.xx.xxxx while simulating -  the error message saying that  "posting takes place in the previous fiscal year". When i wanted  to overwrite the error message
    it is telling that --in company code number range 19 is missing for the fiscal year. For the customer the number range 21 is missing. I gave the number ranges while creating vendors and customers accounts. As the document types are already given in default. I haven't changed them.
       As such invoice postings is not saved.
    Pls help me out in this regard.
    Thanks in advance
    regards
    Jyothsna Singh

    Hi....
    The error pertains to maintaining accounting doc number ranges.
    Go to T.code FBN1-- Give company codeselect change intervals buttonCreate number ranges14,16 and 18 for customers and 15,17 and 19 and 21 (21 if required) for the fiscal year.
    Save data.
    Post the doc
    Assign points if helpful
    Regards
    Aravind
    Message was edited by:
            A.Aravind

  • Multisim user error user.ewfg not found

    Hello ! I have a problem with Multisim 8: i've installed it as administrator and when i try to launch it as a user (the user name is student) i get this error: student.ewfg not found default.ewfg nor found! i have enabled Full control options and it still doesn't work. It would be great if anyone can help me. Thank you

    If you logged on the machine with an ‘admin” account Multisim
    starts but when logged on with a "user" account, it does not, then
    this have to be a permission issue.  You need to give everyone full access
    to the following folders:
    1.  Multisim user
    2.  Database
    Double check mscomp_s.prd inside the database folder, the permission you set on
    the Database folder does not inherent to this file.
    Tien P.
    National Instruments

  • Simulation error: C:\USERS... No such file or directory

    When I try to simulate I get this error: C:\USERS\LISA: No such file or directory

    Hello,
    Please send us more details:
    - Multisim version/edition
    - Operating System
    - Do you use an Administrator account in your PC?
    - Do you get the error with a specific schematic?
    Regards,
    Fernando D.
    National Instruments

  • Simulation error in ERM

    Hi Experts,
    We are on GRC AC 5.3 and ERM patch level is: 7_0
    I was simulating a role from change view-> Risk Analysis-> simulate-> iclude users-> yes-> clicked on simualte.
    In configuratio->background jobs, the job status is showing as completed. when drilling down inside in Job history it is showing the message at step 3 that:  Error in backend system/Web service; Name or password is incorrect (repeat logon).
    In Simulation option in the risk analysis also it is showing no logs.
    FYI,  Both Adopters and connectors are working fine. I am stuck in between
    Could any one please tell me, how to resolve the error?
    Regards,
    Gurugobinda

    Hi Alpesh,
    Thank you very much for analyzing the issue and suggesting me the closest solution.
    I am also feeling the same.
    Hi Satyabrata,
    Thanks a lot for your response.
    Regards,
    Gurugobinda

Maybe you are looking for

  • Google Maps Navigation and Google Music problem

    Hello, I love the LG G2 but it has a few concerning issues. First, is the squealling, hissing, cracking, popping, etc. during phone calls, but I have seen that brought up by others. The second problem that I've discovered, and the most upsetting to m

  • Regarding the Discount condition type in sales order

    Hi All I have 3 key combinations in my Discount Condition Type. I have maintained records at all the 3 key combinations and all the records are relevant for a sales. In my sales order all the relevant records (all 3 records) getting displayed, but fo

  • New computer, files always stored on external drive, will not transfer

    Forgive me for this question if it's been answered before, but I've searched through the forums and have not found an answer so I hope you can help this clueless newbie. My old computer crashed. All my music files have always been stored on an extern

  • Is it safe to upgrade my 21" iMac from 4GB to 12GB of RAM

    I want to upgrade my iMac 21" from 4GB of RAM to 12GB and was just wondering if this was safe/ ok?

  • Problems with basic ADC

    Hi there, I have a some problems getting a basic ADC circuit to work. I've attached the file. Where do I go wrong? Thanks for any help! Attachments: ADC-generic.ms10 ‏105 KB