Nexus 7000 show tech-support

Is there a way to do a show tech-support and pipe it to a file or tftp so that I can send it to a vendor?  If so, what would the command be?
Thanks.
Jeff

You can use the redirect feature
show tech-support > bootflash:tsupport_file
http://www.cisco.com/en/US/partner/docs/switches/datacenter/sw/4_2/nx-os/fundamentals/command/reference/fnd_commands.html#wp1136081
Thanks
Hatim

Similar Messages

  • Using ACS to deny show tech-support

    I am trying to deny the show tech-support command using Cisco Secure ACS command authorization sets (picture included). All other deny commands are working (is show running-config) but no matter what I do the show tech is un-successful. Any ideas?

    Do you have these authorization commands configured?
    aaa new-model
    aaa authentication login default group tacacs+ local
    aaa authorization exec default group tacacs+ local
    aaa authorization commands 0 default group tacacs+ local
    aaa authorization commands 1 default group tacacs+ local
    aaa authorization commands 15 default group tacacs+ local
    tacacs-server host 10.1.1.1 key cisco123
    Debug aaa author should display:
    AAA/AUTHOR/CMD: tty2 (2846421758) user='switchuser'
    AAA/AUTHOR/CMD (2846421758): send AV service=shell
    AAA/AUTHOR/CMD (2846421758): send AV cmd=show
    AAA/AUTHOR/CMD (2846421758): send AV cmd-arg=tech-support
    AAA/AUTHOR/CMD (2846421758): send AV cmd-arg=
    AAA/AUTHOR/CMD (2846421758): found list "default"
    AAA/AUTHOR/CMD (2846421758): Method=tacacs+ (tacacs+)
    AAA/AUTHOR/TAC+: (2846421758): user=switchuser
    AAA/AUTHOR/TAC+: (2846421758): send AV service=shell
    AAA/AUTHOR/TAC+: (2846421758): send AV cmd=show
    AAA/AUTHOR/TAC+: (2846421758): send AV cmd-arg=tech-support
    AAA/AUTHOR/TAC+: (2846421758): send AV cmd-arg=
    TAC+: Using default tacacs server-group "tacacs+" list.
    TAC+: Opening TCP/IP to 10.1.1.1/49 timeout=5
    TAC+: Opened TCP/IP handle 0x2E8FEA4 to 10.1.1.1/49
    TAC+: 10.1.1.1 (2846421758) AUTHOR/START queued
    TAC+: (2846421758) AUTHOR/START processed
    TAC+: (-1448545538): received author response status = FAIL
    Make sure to modify the original ACS Shell Command Authorization...
    deny tech-support instead of deny tech.

  • Show Tech-support

    I ran the command show tech-support without page and other options on IDS, output is just going on from last 2 hours. I phave pressed ^c many times but it's not coming to prompt and not stopping.
    If any one have solution please update..

    You should be able to stop it using 'CTRL+C'.

  • Show tech support hanging at initiating.

    Hi all,
    UCS blade M3 200 is showing RAM Degraded.
    Confirmed RAM inventory was identic in the OS and BIO.
    Acknowladge the error
    reset the bmc
    None of these resolve the issue.
    I decided to collect collect the show tech support but this is stuck at initiating
    How can I clear this process and re-issue the show tech support to see if this run

    Rami,
    What version of UCSM??
    If the system is still sitting at initializing the tech bundle you can try to force a switchover. 
    connect local-management
    cluster lead b
    A RAM degraded message means the system has detected a correctable error but is still being used.  This isn't something you can clear by acknowledging the error.  It could indicate a problem DIMM.  If the OS and BIOS display the max memory amount this means it has not mapped out - which is good.  Have a look at the blade's memory stats and see how frequently the CE memory errors are happening.  If they happen as a one-time event they may eventually clear.  If they continue to occur you should open a TAC case and replace the DIMM.
    Regards,
    Robert

  • Show tech-support from Nexus

    Is there a way to disable the pager on the Nexus5k so that I don't need to continuously hit the "space" when doing "show tech"?

    You can then copy the file off to a FTP/TFTP/SCP server.  The no-more works as well, but this is a handy trick.
    I agree.  I've never seen the "no-more" before.
    There's another one:  sh tech | redirect tftp:///filename.txt"

  • Is it possible to limit the output of "show tech-support" to the data from a single switch in a cluster?

    I need to provide the output for one 3750x switch out of a cluster of 7.
    With all of the various stats, the entire log will be fairly large.

    From the master switch open a session to that switch and than run "sh tech-support"
    session 7
    sh tech
    HTH

  • Nexus 7000 Show Run in XML

                      Hi Guys,
    I would like to obtain the show run output in XML. We are running Nexus 7010 version 6.1(4). After multiple reaches, I found out that we need to load the xsd file to the bootflash. So, I've downloaded the n7000_xsd.6.2.6.tar.gz file from the Cisco web site. My question is:
    Do I need to unzip the file before it can be accessed?
    How do I active the xsd file from the bootflash?
    How can I get the running configuration in XML format?
    FYI, show ip arp | xml is working fine but show run | xml is still giving me the output in text format. Your help is greatly appreciated.

    Hello Allen,
    we have prioritized this now. Fix for the enhancement (CSCuj13151) would come in June 2014 in 7.x release. we are also planning to backport the fix in the 6.x release tentative around June 2014.
    https://tools.cisco.com/bugsearch/bug/CSCuj13151/?reffering_site=dumpcr
    Thanks,
    Richard.
    *Rate if its useful.

  • We have router 7609s,so we need to know,router RAM,so how it will get i have show tech-support configuration.can you tell me pls

    how will get ram of router 7609s and 7206 ,can you tell whats bydefault RAM of both routers,please give me response ASAP.

    Hello
    Do you want to know how much RAM you have in 7600, Show version command can be use to find it
    Cisco 7206VXR (NPE400) processor (revision A) with 245760K/16384K bytes of memory.
    Above router has 245760K+16384K/1024 = 256MB of RAM.
    Thanks
    Kunal

  • ACE 20 Modular - show tech too large

    Hi
    A Client sent me a show tech of this ACE 20, is inserted into a VSS, but this file is very large, the reason is a command "show acl-merge merged-list vlan 93".. Somebody can tell me is this information is normal, or not, I think that is possible attack point to the farm server. the service is up, in the other ace20. the symptom is can not reach the VIP of the service.
    `show acl-merge merge vlan 93 in`
    All ACEs in merged list 5 Total:6377 Non-redundant:5608
    Priority:164, Lineno:0, ACE-id:61470 Action:PERMIT, Path-id:0x81/0x0/0x0:6/0[6/]
    Pmap:0x5, Log:FALSE/FALSE[FALSE][FALSE], Interval:0/0[0][0]
    Hash1:0x0 Hash2:0x0
    Generated:TRUE, need-to-add-in-comp:NO_ACT_NEEDED, redundant:FALSE
    Parent:: feature:SECURITY ace-lineno:8 ACL priority:0[G:0,P:0,C:0,ACL:0]
    Parent:: feature:TO CP ace-lineno:2 ACL priority:16779265[G:0,P:1,C:8,ACL:1]
    Feature:SECURITY Policy:1[1][1] sec-level:0x0 Intratype:SKIP
    Feature:TO CP Policy:1[1][1] sec-level:0x0 Intratype:TERMINATE
    Intertype:TERMINATE     
    IP address SRC:0.0.0.0/0.0.0.0 DST:172.23.98.20/255.255.255.255
    Ports SRC:RANGE 8 8 DST:RANGE 0 0       
    Protocol:1
    Hit Count:0 Active:TRUE Timerange:0
    Priority:326, Lineno:0, ACE-id:61471 Action:PERMIT, Path-id:0x81/0x0/0x0:6/0[6/]
    Pmap:0x5, Log:FALSE/FALSE[FALSE][FALSE], Interval:0/0[0][0]
    Hash1:0x0 Hash2:0x0
    Generated:TRUE, need-to-add-in-comp:NO_ACT_NEEDED, redundant:FALSE
    Parent:: feature:SECURITY ace-lineno:8 ACL priority:0[G:0,P:0,C:0,ACL:0]
    Parent:: feature:TO CP ace-lineno:2 ACL priority:16781313[G:0,P:1,C:16,ACL:1]
    Feature:SECURITY Policy:1[1][1] sec-level:0x0 Intratype:SKIP
    Feature:TO CP Policy:1[1][1] sec-level:0x0 Intratype:TERMINATE
    Intertype:TERMINATE     
    IP address SRC:0.0.0.0/0.0.0.0 DST:165.183.93.51/255.255.255.255        
    Ports SRC:RANGE 8 8 DST:RANGE 0 0       
    Protocol:1
    Hit Count:0 Active:TRUE Timerange:0
    Priority:487, Lineno:0, ACE-id:61472 Action:PERMIT, Path-id:0x81/0x0/0x0:6/0[6/]
    Pmap:0x5, Log:FALSE/FALSE[FALSE][FALSE], Interval:0/0[0][0]
    Hash1:0x0 Hash2:0x0
    Generated:TRUE, need-to-add-in-comp:NO_ACT_NEEDED, redundant:FALSE
    Parent:: feature:SECURITY ace-lineno:8 ACL priority:0[G:0,P:0,C:0,ACL:0]
    Parent:: feature:TO CP ace-lineno:2 ACL priority:16783361[G:0,P:1,C:24,ACL:1]
    Feature:SECURITY Policy:1[1][1] sec-level:0x0 Intratype:SKIP
    Feature:TO CP Policy:1[1][1] sec-level:0x0 Intratype:TERMINATE
    Intertype:TERMINATE     
    IP address SRC:0.0.0.0/0.0.0.0 DST:165.183.93.51/255.255.255.255        
    Ports SRC:RANGE 8 8 DST:RANGE 0 0       
    Protocol:1
    Hit Count:0 Active:TRUE Timerange:0
    Priority:647, Lineno:0, ACE-id:61473 Action:PERMIT, Path-id:0x81/0x0/0x0:6/0[6/]
    Pmap:0x5, Log:FALSE/FALSE[FALSE][FALSE], Interval:0/0[0][0]
    Hash1:0x0 Hash2:0x0
    Generated:TRUE, need-to-add-in-comp:NO_ACT_NEEDED, redundant:FALSE
    Parent:: feature:SECURITY ace-lineno:8 ACL priority:0[G:0,P:0,C:0,ACL:0]
    Parent:: feature:TO CP ace-lineno:2 ACL priority:16785409[G:0,P:1,C:32,ACL:1]
    Feature:SECURITY Policy:1[1][1] sec-level:0x0 Intratype:SKIP
    Feature:TO CP Policy:1[1][1] sec-level:0x0 Intratype:TERMINATE
    Intertype:TERMINATE     
    IP address SRC:0.0.0.0/0.0.0.0 DST:165.183.93.61/255.255.255.255        
    Ports SRC:RANGE 8 8 DST:RANGE 0 0       
    Protocol:1
    Hit Count:0 Active:TRUE Timerange:0

    Hi.
    We reboot the ACE20, and let one contex in this module..  The services is OK now, but my only doub is why the show tech-support is too large and appear the out of command show acl-merge merged-list vlan 93, with a lot of line.. 
    I try to run command "show tech-support" again and submit.

  • For those of you with a Windows computer and the iOS device is not syncing or showing up in iTunes. here is a known solution that has been working for tech support!

    I know this seems to be an emerging issue ever since the update to iTunes 11.1.4, some iPhones or other iOS devices are not showing up in iTunes or syncing. I'm not sure if Apple really knowns of this issue, but tech support has a (mostly) sure fire way of resolcing this issue. It's only for Windows computers though.
    Go to the article http://support.apple.com/kb/ts1538 and follow the Section 5 Verify Apple Mobile Device USB driver is installed. When you clik on that section, go to your version of Windows (it seems to be happening mostly across Windows 8) . And then to the section: If Apple iPod, Aple iPhone, or Apple iPad is listed.
    The gist of what you need to do:
    Windows 8 (since it seems to be the most affected) move your cursor to the upper ight corner of your screen) and click on the Magnifying glass. Type in devmgmt.msc and this should bring up the Device Manager. Onc eyou are in the device manager, look for the "Portable device" or "Universial Serial bus Controller" list, and you should see the "Apple iPhone/iPad/iPod" listed. Onc eyou see it, right click it, choose "Update software driver." Now, IT WILL SAY THE DRIVER IS UPDATED. I CANNOT STRESS THIS ENOUGH. Select "Browse my computer for driver software." Onc eyou choose that, select "Let me pick from a lsit of drivers on my computer." You should see the option "Have Disk." Choose that. Again, I KNOW you do not have a physical disk, but the file we need is already on your computer. After Hard Disk, choose Browse again. Follow this file path to the file we need: C:\Program Files\Common Files\Apple\Mobile Device Support\Drivers.. In the Driver's folder, you should see the "usbaaple" or "usbappl64" (if you have the 64 bit for Windows). Double click on that file, and hit OK. The file should install, and once it's finished check your iTunes!!! You may want to unplug your device and plug it back it before doing all of this. I REALLY hope this works for you all as well!

    How can I change my file extension from m4p to something else? I have had no success being able to play or burn my purchased music. I keep getting error 2122. If I can change the format I should be able to move it to another player or at least burn it in Nero. Thanks.
    Angie

  • NAT support on the Nexus 7000?

    Hi
    I've been trying to determine if the Nexus 7000 supports NAT. I've had a look around but can't find anything definitive, if anybody can confirm whether the 7K supports NAT it'd be much appreciated.
    Thanks
    Malc

    Page 20-21 of this switch guide has a chart that says h/w NAT isn't supported. The NX-OS config guides I've seen that mention NAT do so in the context of IPv6 saying IPv6 eliminates the need for NAT/PAT, so I wouldn't count on seeing NAT in the 7k's. Grab a 6500 dedicate a router to that purpose.

  • Nexus 7000 SSL wildcard SSL certificate support ?

    Hello
    i want to verify if Nexus 7000 supports Wildcard SSL's.
    Cheers

    I have the same problem on a 5515-X, and I've tried pretty much the  same things. The weird thing for me is that everything worked great  until I did an OS upgrade. Back on 8.6.1, my browser successfully  verified the certificate on my SSL VPN login page, and AnyConnect never  brought up any warning boxes. But after I upgraded to 9.1.3, the box was  back to using a self-signed cert. The wildcard identity certificate  seems to have just disappeared, though the GoDaddy CA cert and my local  CA cert both stayed intact.
    I've used OpenSSL to convert and verify my cert file  in a number of different ways, but all of my supposedly valid files  still get the import operation failed message. So it seems like there  was some OS change that suddenly made my wildcard incompatible, but I  haven't figured out what it is yet.
    Hope this helps, for both our sakes.

  • Nexus 7000 and 2000. Is FEX supported with vPC?

    I know this was not supported a few months ago, curious if anything has changed?

    Hi Jenny,
    I think the answer will depend on what you mean by is FEX supported with vPC?
    When connecting a FEX to the Nexus 7000 you're able to run vPC from the Host Interfaces of a pair of FEX to an end system running IEEE 802.1AX (802.3ad) Link Aggregation. This is shown is illustration 7 of the diagram shown on the post Nexus 7000 Fex Supported/Not Supported Topologies.
    What you're not able to do is run vPC on the FEX Network Interface that connect up to the Nexus 7000 i.e., dual-homing the FEX to two Nexus 7000. This is shown in illustrations 8 and 9 of under the FEX topologies not supported on the same page.
    There's some discussion on this in the forum post DualHoming 2248TP-E to N7K that explains why it's not supported, but essentially it offers no additional resilience.
    From that post:
    The view is that when connecting FEX to the Nexus 7000, dual-homing does not add any level of resilience to the design. A server with dual NIC can attach to two FEX  so there is no need to connect the FEX to two parent switches. A server with only a single NIC can only attach to a single FEX, but given that FEX is supported by a fully redundant Nexus 7000 i.e., SE, fabrics, power, I/O modules etc., the availability is limited by the single FEX and so dual-homing does not increase availability.
    Regards

  • NEXUS 7000 xcvrInval

    Hi,
    I have some Nexus 7000 with FET-10G with xcvrInval status
    Eth7/33          N5k-S1-3T-1/3   xcvrInval trunk     auto    auto    Fabric Exte
    and some other FET-10G with notconn status
    Eth7/8           FEX-101         notconnec 1         auto    auto    Fabric Exte
    If I inter exchange the position of both FET-10G the status port doesn´t change
    FET-10G from 7/8 to 7/33
    FET-10G from 7/33 to 7/8
    7/33 holds xcvrInval status
    7/8 holds notconnec status
    I have reconfigured from default interface with same results
    Next you´ll find the same serial number in deferent port, the diference is the current
    when is xcvrInva or when is notconnec
    What can I do to get FET10G in e7/33 validated?
    sh interface e7/33   transceiver details
    Ethernet7/33
          transceiver is present
          type is Fabric Extender Transceiver
          name is CISCO-FINISAR  
          part number is FTLX8570D3BCL-C2
          revision is A  
          serial number is FNS17201TE5    
          nominal bitrate is 10300 MBit/sec
          Link length supported for 62.5/125um fiber is 10 m
          Link length supported for 50/125um OM3 fiber is 100 m
          cisco id is --
          cisco extended id number is 4
          cisco part number is 10-2566-02
          cisco product id is FET-10G            
          cisco vendor id is V02
          number of lanes 1
                 SFP Detail Diagnostics Information (internal calibration)
                    Current              Alarms                  Warnings
                    Measurement     High        Low         High          Low
        Temperature   19.30 C        75.00 C      5.00 C     70.00 C       10.00 C
    [7m--More-- [m
        Voltage        3.31 V         3.63 V      2.97 V      3.46 V        3.13 V
        Current        0.06 mA  --     11.80 mA     4.00 mA    10.80 mA       5.00 mA
        Tx Power          N/A        22.69 dBm    8.69 dBm     18.69 dBm     12.69 dBm
        Rx Power          N/A        22.99 dBm    6.09 dBm     18.99 dBm     10.09 dBm
        Transmit Fault Count = 0
        Note: ++  high-alarm; +  high-warning; --  low-alarm; -  low-warning
    now in slot 7/8
    Ethernet7/8
          transceiver is present
          type is Fabric Extender Transceiver
          name is CISCO-FINISAR  
          part number is FTLX8570D3BCL-C2
          revision is A  
          serial number is FNS17201TE5    
          nominal bitrate is 10300 MBit/sec
          Link length supported for 62.5/125um fiber is 10 m
          Link length supported for 50/125um OM3 fiber is 100 m
          cisco id is --
          cisco extended id number is 4
          cisco part number is 10-2566-02
          cisco product id is FET-10G            
          cisco vendor id is V02
          number of lanes 1
                 SFP Detail Diagnostics Information (internal calibration)
                    Current              Alarms                  Warnings
                    Measurement     High        Low         High          Low
        Temperature   23.17 C        75.00 C      5.00 C     70.00 C       10.00 C
    [7m--More-- [m
        Voltage        3.30 V         3.63 V      2.97 V      3.46 V        3.13 V
        Current        7.50 mA       11.80 mA     4.00 mA    10.80 mA       5.00 mA
        Tx Power      17.65 dBm      22.69 dBm    8.69 dBm     18.69 dBm     12.69 dBm
        Rx Power     -12.21 dBm --   22.99 dBm    6.09 dBm     18.99 dBm     10.09 dBm
        Transmit Fault Count = 0
        Note: ++  high-alarm; +  high-warning; --  low-alarm; -  low-warning
    NX7K-1-VDC-3T-S1-L2FP# sh int e7/33
    Ethernet7/33 is down (Transceiver validation failed)
    admin state is up, Dedicated Interface
      Belongs to Po51
      Hardware: 1000/10000 Ethernet, address: 8478.ac23.6cec (bia 8478.ac23.6cec)
      Description: N5k-S1-3T-1/3
      MTU bytes (CoS values):  MTU  1500(0-2,4-7) bytes  MTU  2112(3) bytes
      BW 10000000 Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA, medium is broadcast
      Port mode is trunk
    auto-speed  auto-duplex,, media type is 10G
      Beacon is turned off
      Auto-Negotiation is turned on
      Input flow-control is off, output flow-control is off
      Auto-mdix is turned on
      Rate mode is dedicated
      Switchport monitor is off
      EtherType is 0x8100
      EEE (efficient-ethernet) : n/a
      Last link flapped never
      Last clearing of "show interface" counters 07:22:09
      0 interface resets
      Load-Interval #1: 30 seconds
        30 seconds input rate 0 bits/sec, 0 packets/sec
        30 seconds output rate 0 bits/sec, 0 packets/sec
      Load-Interval #2: 5 minute (300 seconds)
        300 seconds input rate 0 bits/sec, 0 packets/sec
        300 seconds output rate 0 bits/sec, 0 packets/sec
      RX
        88 unicast packets  0 multicast packets  0 broadcast packets
        0 input packets  0 bytes
        0 jumbo packets  0 storm suppression packets
        0 runts  0 giants  0 CRC/FCS  0 no buffer
        0 input error  0 short frame  0 overrun   0 underrun  0 ignored
        0 watchdog  0 bad etype drop  0 bad proto drop  0 if down drop
        0 input with dribble  0 input discard
        0 Rx pause
      TX
        88 unicast packets  0 multicast packets  0 broadcast packets
        0 output packets  0 bytes
        0 jumbo packets
        0 output error  0 collision  0 deferred  0 late collision
        0 lost carrier  0 no carrier  0 babble  0 output discard
        0 Tx pause
    NX7K-1-VDC-3T-S1-L2FP# sh int e7/33
    Ethernet7/8 is down (Link not connected)
    admin state is up, Dedicated Interface
      Belongs to Po101
      Hardware: 1000/10000 Ethernet, address: 8478.ac23.6cd3 (bia 8478.ac23.6cd3)
      Description: FEX-101
      MTU bytes (CoS values):  MTU  1500(0-2,4-7) bytes  MTU  2112(3) bytes
      BW 10000000 Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA, medium is p2p
      Port mode is fex-fabric
    auto-speed  auto-duplex,, media type is 10G
      Beacon is turned off
      Auto-Negotiation is turned on
      Input flow-control is off, output flow-control is off
      Auto-mdix is turned on
      Rate mode is dedicated
      Switchport monitor is off
      EtherType is 0x8100
      EEE (efficient-ethernet) : n/a
      Last link flapped 5week(s) 1day(s)
      Last clearing of "show interface" counters never
      0 interface resets
      Load-Interval #1: 30 seconds
        30 seconds input rate 0 bits/sec, 0 packets/sec
    [7m--More-- [m
        30 seconds output rate 0 bits/sec, 0 packets/sec
      Load-Interval #2: 5 minute (300 seconds)
        300 seconds input rate 0 bits/sec, 0 packets/sec
        300 seconds output rate 0 bits/sec, 0 packets/sec
      RX
        10588 unicast packets  0 multicast packets  0 broadcast packets
        4 input packets  0 bytes
        0 jumbo packets  0 storm suppression packets
        0 runts  0 giants  0 CRC/FCS  0 no buffer
        0 input error  0 short frame  0 overrun   0 underrun  0 ignored
        0 watchdog  0 bad etype drop  0 bad proto drop  0 if down drop
        0 input with dribble  0 input discard
        0 Rx pause
      TX
        10588 unicast packets  1 multicast packets  0 broadcast packets
        4 output packets  5688 bytes
        0 jumbo packets
        0 output error  0 collision  0 deferred  0 late collision
        0 lost carrier  0 no carrier  0 babble  0 output discard
        0 Tx pause

    Hi Ans,
    You are rigth, I have defaulted againt the port, now configured with switchport mode FEX, and now the FET-10G is validated
    NX7K-1-VDC-3T-S1-L2FP(config-if)#  description FEX-101
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   switchport
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   switchport mode fex-fabric
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   fex associate 101
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   medium p2p
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   channel-group 101
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   no shutdown
    NX7K-1-VDC-3T-S1-L2FP(config-if)#
    NX7K-1-VDC-3T-S1-L2FP(config-if)# sh int e7/33 status
    Port             Name            Status    Vlan      Duplex  Speed   Type
    Eth7/33          FEX-101         notconnec 1         auto    auto    Fabric Exte
    NX7K-1-VDC-3T-S1-L2FP(config-if)#
    Thanks for your help, and have a nice weekend.
    Atte,
    EF

  • SFP Detail Diagnostics Information Nexus 7000

    Hello guys,
    I have a question about why one port on a Nexus 7000 with a N7K-M132XP-12 (32 port 10G card) doesn't show any values
    when looking at "show inter e 9/27 transceiver details", all values are just zero.
    N7K# show inter e 9/27 transceiver details
    Ethernet9/27
     transceiver is present
     type is 10Gbase-SR
     name is CISCO-EXCELIGHT
     part number is SPP5101SR-C1
     revision is A
     serial number is EXX13050136
     nominal bitrate is 10300 MBit/sec
     Link length supported for 50/125um OM2 fiber is 82 m
     Link length supported for 62.5/125um fiber is 26 m
     Link length supported for 50/125um OM3 fiber is 300 m
     cisco id is --
     cisco extended id number is 4
     number of lanes 1
     SFP Detail Diagnostics Information (internal calibration)
     Current Alarms Warnings
     Measurement High Low High Low
     Temperature N/A 0.00 C 0.00 C 0.00 C 0.00 C
     Voltage N/A 0.00 V 0.00 V 0.00 V 0.00 V
     Current N/A 0.00 mA 0.00 mA 0.00 mA 0.00 mA
     Tx Power N/A 0.00 dBm 0.00 dBm 0.00 dBm 0.00 dBm
     Rx Power N/A 0.00 dBm 0.00 dBm 0.00 dBm 0.00 dBm
     Transmit Fault Count = 2
     Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
    Tried to remove the SFT+ and inserted a new, but same results, all values are 0.
    Does anyone know why it doesn't show any values?
    We are runing version 6.2(8)
    And here's the port configuration:
    interface Ethernet9/27
     switchport
     switchport mode trunk
     spanning-tree port type edge trunk

    You are correct.  There isn't any option for seeing the hit count on the prefix-list on the Nexus series.
    HTH

Maybe you are looking for

  • What are all the ways to clean the ipad smart cover?

    my smart cover is getting quite dirty, i would like to know what are the ways of cleaning it without damaging it, itis not a leather cover

  • Ipod overheating and not turning on

    My Ipod touch 2nd Gen wont turn on even though i has charge and the back of the ipod is really hot, any suggestions?

  • Registration of adobe

    In design cs4 not showing up under my adobe ID after 24hours. No email from adobe has been sent either. Who do I call other than a robot.

  • Problem in SICF

    Hi, I want to have automatic logon into a bsp page (application) ICF path: /default_host/sap/bc/bsp/sap/ Everthing works fine in SAP DEV and when I transport it to SAP TEST there seems to be a problem because none of the fields in "Anonymous Logon Da

  • Changing Bubblesize in Portfoliochart by URL-Command

    Hello all, in our case we have filled the third column of the datatable with fixed values (e.g. 10). So the bubblesize of all dataseries is the same (requirement of our customer). So, the only way to change the bubble size is to change the value of t