Open Dataset No Authority runtime error

Hi friends
I am getting error like this
No Authorization to open the file 'HCM_PAYROLL_MDATA_IT2010.LSMW.READ'.
Can anyone help me . whay i am getting .
Error in the abap program /1cadmc/sap_lsmw_read_00000036' had to be terminated coz it has come crass a statement that unfortunately cannot be excuted.

Could you please explain wht you was trying to do
wht code you wrote?
For better understanding
Best Regards

Similar Messages

  • Can't open PDFs, Initially received runtime error,updated Reader - new error Adobe Reader has stopped working, uninstalled re-installed same error message Adobe Reader has stopped working

    Can't open PDFs, Initially received runtime error,updated Reader - new error Adobe Reader has stopped working, uninstalled re-installed same error message Adobe Reader has stopped working

    Assuming that you are in Win (which you haven't said), you can try using this tool to first remove all traces of previous versions of Reader:
    http://labs.adobe.com/downloads/acrobatcleaner.html
    Then, download the full offline Reader installer from 
    http://get.adobe.com/reader/enterprise/
    and run it immediately after restarting your computer.

  • While installing latest update I lost ability to open Itunes.  Getting "runtime error" and then next box says error 1114.  Tried uninstalling and reinstalling and does not work.  Getting same error.  Very frustrating.

    Cannot open Itunes after trying to install latest update.  Getting runtime error and then error 1114.  Tried uninstalling and reinstalling and still getting same error.  How do I fix this.  Very frustrating!

    Hi there,
    Earlier iTunes (and supporting applications) need to be completely uninstalled before you can install the new version. Here's the complete Apple info on this: http://support.apple.com/kb/HT1923
    Mobile device application will most likely fail to uninstall, so you would need to visit its location(s) and manually delete the files then folder(s). The location of the folders is documented in this link from Apple.
    It's a pain, but it should work.

  • Unable to Open Inbox in SBWP - runtime error

    Hi Gurus,
    I have a problem with my inbox - I'm experiencing runtime error (time_out) when opening it. It says 'Time limit exceeded', and 'The program 'SAPFSSO0' has exceeded the maximum permitted runtime without interruption and has therefore been terminated.
    Can anyone of the Workflow experts tell me what is the probable cause, and what do you sugggest to solve this and prevent from happening again?
    Thanks!
    Regards,
    Joyreen

    This may or may not solve your problem but gives you an idea on performance of SBWP.
    Check the Note 764707 - Performance in Business Workplace
    This note describes the factors that affect the performance in the Business Workplace, and ways in which you can improve the performance:
    The performance in the workflow inbox depends on several factors:
    1. Use of organizational objects (O, S ...) for tasks
    If agent assignment for tasks is controlled using organizational objects, a structural explosion is necessary. Complex organizational structures can mean that the time required to construct the inbox is greater. This is carried out once a day for each user when the user logs on initially, and the information is then buffered. As a result, the initial construction of the inbox takes the most time.
    2. Number of work items in the system
    The time required for selecting work items for a user increases with the number of work items that exist in the system.
    3. Number of work items that are displayed in the workflow inbox or in the subordinate views.
    4. Use of dynamic columns
    The dynamic columns are filled on a task-specific basis with content that is determined dynamically during runtime. To do this, it is necessary for the system to read the work item container and then to determine the attributes to be displayed, for example, of an business object.
    Displaying the dynamic columns greatly affects performance, since the system accesses both the work item container and application tables.
    5. Grouping according to contents, content type and sort key
    Each work item carries the two container elements WIObject_ID (dominant object) and WIGroup_ID (Grouping characteristic) to its container. Both elements are defined so that an object reference can be included.
    Grouping according to content and content type is based on the container element WIObject_ID, and grouping according to sort key is based on WIGroup_ID. For each of these grouping types, the system needs to access the container for each work item to read the object reference. In addition, the system must determine the default attribute of the respective object, which involves accessing the application tables.
    6. Showing the columns group object and work item contents
    As above, showing the two columns is based on the container elements WIObject_ID and WIGroup_ID. The system determines the values to be shown by reading the work item container and the default attribute of the relevant object.
    Solution
    1. Detail the assignment of tasks in the organizational model.
    2. Archive work items that are no longer needed (see Note 49545).
    3. In the Business Workplace, BAdIs are available for the following purposes:
    a) WF_BWP_SELECT_FILTER
    This BAdI enables you to limit the number of the work items displayed by filtering. It is mainly suited to scenarios where all users are working on the same inventory of work items (for example, call center).
    (see Note 765783)
    b) WF_BWP_DYN_COLUMN
    Hiding the dynamic columns improves performance in the Business Workplace.
    If this is not possible, you can implement the BAdI WF_BWP_DYN_COLUMN to determine the values of the dynamic columns directly from the application data. The BAdI is available with Note 848382.
    c) WF_BWP_OBJ_ATTRIBUTE
    With this BAdI, it is possible to set the default attributes of the dominant object (_WI_Object_ID) and the grouping characteristic (_WI_Group_ID). The default attributes are used for grouping according to content, and grouping according to sort key and for hiding the group object column and work item content.
    The BAdI is available with Note 848382.
    4. It is also advisable to implement Note 848382 (or one of the corresponding Support Packages) if you do not want to implement either of the BAdIs. The note also contains an optimization that affects the determination of the object references in the container elements WIObject_ID and WIGroup_ID.
    Header Data
    Regards,
    PR.

  • Runtime error R6025 Pure virtual function call....the program shuts down as soon as its opened

    iTunes shuts down as soon as it is opened.  Message says Runtime error R6025.  pure virtual function call.  What is this and can it be fixed???

    For general advice see Troubleshooting issues with iTunes for Windows updates.
    The steps in the second box are a guide to removing everything related to iTunes and then rebuilding it which is often a good starting point unless the symptoms indicate a more specific approach. Review the other boxes and the list of support documents further down page in case one of them applies.
    Your library should be unaffected by these steps but there is backup and recovery advice elsewhere in the user tip.
    If you've already tried a complete uninstall and reinstall try opening iTunes in safe mode (hold down CTRL+SHIFT) as you start iTunes, then going to Edit > Preferences > Store and turing off Show iTunes in the Cloud purchases. You may find iTunes will now start normally.
    tt2

  • Unable to create a file in Application Server using OPEN DATASET stattement.

    I am unable to create a file in Application Server using the following statement.
    OPEN DATASET filename FOR OUTPUT
    IN TEXT MODE ENCODING DEFAULT
    MESSAGE msg.
    The message I'm getting is "Permission Denied". I have checked authorisation using SU53 which says "The last authorization check was successful". Please help.

    You can use following code to capture the error.
    TRY.
          OPEN DATASET filename FOR OUTPUT IN BINARY MODE MESSAGE V_MSG.
          CATCH CX_ROOT
          INTO EXCEPTION.
          CALL METHOD O_EXCEPTION ->IF_MESSAGE~GET_TEXT
            RECEIVING
            RESULT = V_MSG.
          MESSAGE v_msg
          TYPE 'E'.
    ENDTRY.
    You can capture error in v_msg.
    Following are the exceptions for the same:
    Exceptions
    Catchable Exceptions
    CX_SY_FILE_OPEN
    Cause: The file is already open.
    Runtime Error: DATASET_REOPEN
      CX_SY_CODEPAGE_CONVERTER_INIT   
    Cause: The desired conversion is not supported. (Due to specification of invalid code page or of language not supported in the conversion, with SET LOCALE LANGUAGE.)
    Runtime Error: CONVT_CODEPAGE_INIT
    CX_SY_CONVERSION_CODEPAGE
    Cause: Internal error in the conversion.
    Runtime Error: CONVT_CODEPAGE
    CX_SY_FILE_AUTHORITY
    Cause: No authorization for access to file
    Runtime Error: OPEN_DATASET_NO_AUTHORITY
    Cause: Authorization for access to this file is missing in OPEN DATASET with addition FILTER.
    Runtime Error: OPEN_PIPE_NO_AUTHORITY
      CX_SY_PIPES_NOT_SUPPORTED   
    Cause: The operating system does not support pipes.
    Runtime Error: DATASET_NO_PIPE
    CX_SY_TOO_MANY_FILES
    Cause: Maximum number of open files exceeded.
    Runtime Error: DATASET_TOO_MANY_FILES   Non-Catchable Exceptions   
    Cause: An attempt was made to open a pipe that is already open.
    Runtime Error: DATASET_PIPE_POSITION
    Hope that will help you.
    Please reward if useful.

  • Portal Runtime Error on sdn

    Hi,
    On sdn , in the Contribution Points Table , there is a Tab named  Additional Points. I got a link there with text Invitation to SAP Network Profiles
    When i click on that A Page opens with message
    Portal Runtime Error.
    An exception occured while processing your request.
    Any Clue ?
    Regards
    Rajendra

    Hi, Gaikwad
    Same problem with some other members too, this issue has forwarded to concern team refer to [Thread|Invitation to the SAP Network Profiles;  Lakshmipathi's Reply.
    Regards,
    Faisal

  • Runtime Error on Acrobat.exe.

    I am using Acrobat Professional version 8 on XP SP3.  It had always worked in the past but now, after opening, I get a Runtime error when trying to make a new PDF.
    Event Viewer gives:
    "Faulting application acrobat.exe, version 8.1.0.137, faulting module adobeupdater.dll, version 5.0.0.316, fault address 0x000475a3."
    I have run the Repair in the installer from the original distribution disk to no effect.  This was after a system reboot and with nothing else started.  The system runs Trend for security, which had not fully started either when I tried to re-run the program.  I jave also run repair from the Help menu in the application itself, with a reboot afterward.  There have been no significant changes made to the system, except possibly automatic updates, since it was working fine.  It even crashes when I try to get the versionn number form the Help-About menu selection.

    I would suggest going to Help>Repair. Then doing Help>Update to get the updates current. Hopefully that will resolve the problem. When you do a repair from the original CD, you may lose updates.

  • Runtime error affecting only Encore CS5

    My CS5 Creative Suite 5 Production Studio has run fine up to yesterday, on my 64 bit PC with Windows 7 Professional.
    Only Encore CS5 is affected...and only when I try to start a new Encore project.  The crash does not happen if I open an existing Encore project...which opens and works as usual. 
    New Encore projects won't open and get the following alert, crashing Encore:  'This application has requested the Runtime to terminate it in an unusual way.  Please contact the application support team for more information.
    I can't finish my projects and need fast help.

    Hi Stan ... I can't open any new project or save it.  With the 'Basic & Advanced window open I enter the name and location of the new project.  Click OK and then it opens momentarily and a RunTime Error window opens and closes Encore.  It says Windows is looking for a solution, but none is found.  As a result I can't change preferences.
    Up until I held the CTRL SHIFT ALT key upon opening, Encore would let me open past projects..just not new ones.  Now I can't open any of them...new or past.
    But I can open the test project that I open with holding the 3 keys down while opening.
    On older projects I'm now getting a new alert "Could not create Blu-ray ntsc sd mped-2.epr.  The path is not valid.'  Tried 5 past projects and none opened.
    Very frustrating.  All my other Adobe programs open...PhotoShop, Premiere, etc.  Just Encore is affected.
    On another note...over the last few months I get 4 DLL alerts that it can't find them...I just close them and everything runs well...as did Encore up to a few days ago.  May not be related.
    Thanks for your help.

  • Can't execute PSE 10 today...giving me a runtime error and shuts down.

    I have been using this program successfully for sometime but today program won't open because of a runtime error.  I have read some of the posts but they are too complicated for me to understand.  I need a clear answer on how to resolve this. 

    There is another way to remove preferences.
    Go to location "C:\Users\[User]\AppData\Roaming\Adobe\Photoshop Elements" and delete the 10.0 folder there. Please make sure that "Appdata" is hidden folder so you have change the folder visible permission from controlpanel in case you don't see the appdata folder.
    Hope this might help.

  • TS3297 Runtime error R6025

    When trying to open itunes Store, message - Runtime Error R6025 appears & closes i tunes

    someone told me about a quick fix until apple addresses the issue. put a shortcut onto your desktop, right click on the shortcut and choose run as administrator. you can search away. it worked for me.

  • Problem updating itunes, now I can not access, Runtime error R6034 using windows 7

    I need some assistance.
    I am trying to update itunes on my computer. I am getting a message which reads: errors occurred while installing the updates.
    I can not access itunes at all now.
    Also i am getting an error when I open windows which reads:
    Runtime Error!
    an application has made an attempt to load the C runtime library incorrectly.
    please contact the applications support team for more information.
    How do I fix this?

    Hello there, Duane Harris.
    The following Knowledge Base article provides in-depth troubleshooting steps for resolving your issue:
    Can't connect to the iTunes Store
    http://support.apple.com/kb/TS1368
    Thanks for reaching out to Apple Support Communities.
    Cheers,
    Pedro D.

  • PS6 R6034 runtime error

    Hi,
    After installing and opening PS6 I get
    'Runtime Error! R6034 An application has made an attempt to load the C runtime library (Win7 64bit)'
    Clicking on this it will come back seven times, after which PS6 starts.
    Following up on all the advice from Adobe Forums and Microsoft I've tried the following:
    Checked all my updates
    Checked for viruses and malware
    Run CCClean and SysMechanic
    Uninstall PS6
    Reboot
    Run Adobe Creative Suite Cleaner
    Restart
    Install CS6
    Install updates
    No change!
    I've also reinstalled the MS runtime library, tried to start in safe mode, all to no avail.

    Hi Mylenium,
    I am on WIN7 SP1 Professional, 64, 3Ghz, 12Gig mem, fully updated. Wacom Intous 4 (PTK-640) tablet, Nikon Super Coolscan 5000 ED, driven by Viewscan.
    This "thing" is driving me insane, I woud be eternally grateful for your help.
    Netmedve

  • Runtime Error in OPEN DATASET

    Dear All,
    I am trying to upload a text file in application server. But I am getting the run time error which says-
    " For the statement
        "TRANSFER f TO ..."
    only character-type data objects are supported at the argument position
    "f".
    In this case. the operand "f" has the non-character-type "u". The
    current program is a Unicode program. In the Unicode context, the type
    'X' or structures containing not only character-type components are
    regarded as non-character-type."
    If I remove the quantity fields then the error does not happen. But I have to take quantity fields also. Plz tell me what to do. My code is,
    DATA FILENAME like rlgrap-filename VALUE 'MIGO_VALUE.txt'.
    TABLES VBAK.
    DATA D_MSG_TEXT(50).
    DATA : BEGIN OF it_mseg OCCURS 0,
           mblnr TYPE mseg-mblnr,
           mjahr TYPE mseg-mjahr,
           matnr TYPE mseg-matnr,
    *       erfmg TYPE mseg-erfmg,
           werks TYPE mseg-werks,
           lgort TYPE mseg-lgort,
           END OF it_mseg.
    DATA wa LIKE it_mseg.
    SELECT mblnr mjahr matnr werks lgort FROM mseg INTO CORRESPONDING FIELDS OF TABLE it_mseg WHERE bwart = '101'.
    SORT it_mseg BY mblnr.
    OPEN DATASET FILENAME FOR OUTPUT IN TEXT MODE ENCODING DEFAULT
                          MESSAGE D_MSG_TEXT.
    if sy-subrc eq 0.
    message 'File created succesfully in SAP System'(002) type 'S'.
    endif.
    IF SY-SUBRC NE 0.
      WRITE: 'File cannot be opened. Reason:', D_MSG_TEXT.
      EXIT.
    ENDIF.
    * Transferring Data
    LOOP AT it_mseg INTO wa.
    TRANSFER wa to filename.
    ENDLOOP.
    * Closing the File
    CLOSE DATASET FILENAME.
    Thanks,
    Tripod.

    Thanks Sri for your help. I tried to apply the logic, but the  error i am getting here is -
    "IT_MSEG-ERFMG" must be a character-like data object (data type C, N,D, T, or STRING) STRING).
    Same case here, if I remove ERFMG field, i do not get such error.
    data ld_string type string.
    LOOP AT it_mseg INTO wa.
      CONCATENATE it_mseg-mblnr it_mseg-mjahr it_mseg-matnr it_mseg-erfmg it_mseg-werks it_mseg-lgort INTO ld_string.
         endloop.
    With regards,
    Tripod.

  • Open dataset input error

    Hi guys
    i am trying to open more than 100 files  using open dataset input but i am getting below error
      program is abending reading after 50files..
    Program failing in  open data set error  can u help me please?
    143
    144 * Each file is getting into an internal table
    >>>   OPEN DATASET w_file FOR INPUT IN TEXT MODE ENCODING DEFAULT.
    146   IF sy-subrc <> 0.
    147     CONTINUE.
    148   ELSE.
    149     DO.
    150       READ DATASET w_file INTO s700_delta.
    What command I should give here
    Error analysis
        An exception occurred that is explained in detail below.
        The exception, which is assigned to class 'CX_SY_TOO_MANY_FILES', was not
         caught and
        therefore caused a runtime error.
        The reason for the exception is:
        The maximum number of open files (100) has been exceeded.
    please let me know what should makes changes to avoid this abend?

    Standard programming problem, should be rather trivial to find with a quick search. Basically there's always a limit of how many open file handles you can have at a time.
    Please try to consult the ABAP help next time before posting (or search on SCN). A quick check for [open dataset|http://help.sap.com/abapdocu_70/en/ABAPOPEN_DATASET.htm] would've told you the following:
    You can open up to 100 files per internal session. The actual maximum number of simultaneously open files may be less, depending on the platform.
    Most likely you actually don't want to have all those files open at the same time and you simply forgot to use a [close dataset|http://help.sap.com/abapdocu_70/en/ABAPCLOSE_DATASET.htm] after reading each file.

Maybe you are looking for