Operation sequencing in R/3 not scheduled

I have a routing with one operation for a machine.  In APO I need to finite schedule both the machine and the operator capacities.  I created a second work center for the labor and added a parallel sequence to the routing to start and stop at operation 0010.  The formula in the labor work center is the standard for labor capacity and labor scheduling.  The execution time for the standard operation, machine time, and the parallet sequence for the labor is the same.  But when I use the 'schedule' function in the routing to check the scheduling data the machine operation is scheduled correctly but there is no time scheduled for the parallel sequence.
Has anyone had this issue before, and if so what corrective action needs to be taken or what have I set up incorrectly.

I need for APO to finite schedule both resources.  If I create the requirement as a secondary capacity on the work center it is not identified in APO (in the PDS) as a calendar resource.  And only calendar resources can be finite scheduled.  In this case both the machine and the labor are critial.  I cannot over schedule any one machine and I have a limited number of operator capacities.  Therefore both have to be finite scheduled.  I have 36 seperate machines but only 8 operators.  I therefore cannot have more than one order at a time on a machine and no more than eight total orders at any one time due to the limited number of operators.
If I simulate the scheduling in the routing I have duration for the standard operation but nothing for the parallel operation.  In the PDS I only see the capacities for the machine and setup operators which are a second capacity in the machine work center, but no capacity for the parallel operation.
If you have a better idea let me know.
Side note - data for parallel operation is not going to the PDS in APO.  But that's another issue.
Thanks for the info
Regards,
Stan

Similar Messages

  • Scrap quantity to be minus with operation sequence is not check in co11

    hello!
    PP experts
    i have problem in confirmation of production order.
    suppose i have production order of 15 qtys.with four operation to be confirmed (co11).
    operation qty.yield srcap qty.
    0010 1 5 0
    0020 14 1
    0030 14 0
    now, in 0020 operation i have 14 yield & 1 srcap quantity & when i go for 0030
    operation for confirmation it will show the default quantity of previous operation,0020 qty. i,e 14 qtys.but if i put the quantity 15 in this operation (0030)
    its allowing to confirmed 15 qtys. because the plan qty is 15.but i want to minus the 1srcap qty. from 15 plan qty. & system should allowed only 14 qtys
    (15-1=14) for confirmation.plus i want the flexibility of operation sequence not to checked.
    i set operation sequence - error when operation sequence is not adhered to in OPK4,its minus the scrap qty. but not allowing the flexibility of operation sequence
    confirmations.
    please send me the setting for the above query in the confirmation (co11)
    regards,
    mangesh

    Hi,
    The same  question was asked few days before by MR Gowri Sankar. The same question you are repeating
    check in OPKP Production scheduling profile in the confirmation Tab
    Enable the check box Adjustment quantities in order to actuals and then try
    in CO11n.
    Also you need to set the overdelivery tolerance as warning message in opk4.
    Regards,
    nandha

  • Scrap quantity to be minus with operation sequence is not check in co01

    hello!
    PP experts
    i have problem in confirmation of production order.
    suppose i have production order  of 15 qtys.with four operation to be confirmed (co11).
    operation  qty.yield  srcap qty.
    0010          1 5              0
    0020          14              1
    0030          14              0
    now, in 0020 operation i have 14 yield & 1 srcap quantity & when i go for 0030
    operation for confirmation it will show the default quantity of previous operation,0020 qty. i,e 14 qtys.but if i put the quantity 15 in this operation (0030)
    its allowing to confirmed 15 qtys. because the plan qty is 15.but i want to minus the 1srcap qty. from 15 plan qty. & system should allowed only 14 qtys
    (15-1=14) for confirmation.plus i want the flexibility of operation sequence not to checked.
    i set operation sequence - error when operation sequence is not adhered to in OPK4,its minus the scrap qty. but not allowing the flexibility of operation sequence
    confirmations.
    please send me the setting for the above query in the confirmation (co11)
    regards,
    mangesh
    thsnks

    Mangesh
    1) you have confirmed yield qty14 nos in operation 020 , scrap Qty 1
    2) Automatically in during confirmation of operation 030, in yield qty field 14 nos is coming
    3) If you want to change that operation 030, yield qty into 15, system giving error message
    4) you want the system to accept the 15 nos in operation 030
    Pl state whether my understanding is right

  • Operation sequence in BOM

    Hi friends,
    while defining Bill of material, operation sequence number is populating by default as 1, does it really matter to exactly use operation sequence number (10) from routing?
    Will it be any issue from planning or mfg perspective If I setup bill of materials with operation sequence as 1 (as default) and operating sequence numbers in routing are set up as 10, 20, 30 etc... ???
    Please let me know.
    Regards,
    kumar

    Hi,
    Benefits of keeping Operation sequence as 10, 20, 30 etc.
    1. End user will know at which operation particular material from BOM is required
    2. In case of Operation Pull, material will be consumed at appropriate operation sequence (This will not matter if you are using Assembly Pull, Push or any other Supply Type). This will impact costing.
    3. You will be able to add same components against different operations
    4. In case of planning, planning engine will give appropriate suggestions (if Mfg lead time is short then this will not matter)
    5. You will be able to print pick slips based on operation seq. i.e. If you want to issue components required at operation 10 only then you can achieve that using this method
    6. You will be able to scrap components effectively
    etc.
    Regards,
    swapnil Mehar

  • Operation Sequence & Confirmation Type  checked at PO Confirmation-CO11N

    Hi All,
    Thanks in Advance for solution.
    My client wants that, at the time of Production order Confirmation - CO11N, SAP should check Operation Sequence and its Type of Confirmation (Partial or Final)
    For Operation Sequence I have done necessary Configuration (SPRO) settings in Confirmation parameters. But how to check for Confirmation TYPE??
    For Example, I have production order with 5 operations, now if I confirm First (1st) operation with PARTIAL CONFIRMATION, then when I confirm Second (2nd) operation with Final Confirmation, it should check that previous operation is Partially Confirmed and thus allow me to confirm Second operation only Partially. Currently I am able to do Final Confirmation for Second operation in above scenario.
    How can the above thing be restricted please let me know?
    Regards,
    Ravi Davda

    During  configuration  the confirmation parameters are set as per the follow IMG path
    Production> > shopfloor control >> operation >> confirmation >> Define confirmation. Here we have 3 views in the first view of generally valid setting we will
    give check 1) error when operation sequence is not adheredto
                    2)  & 3) Error If over delivery & Underdelivery tolerence is not maintained as per Workscheduling view of Material master record
                    4) Error if the quality inspection value not exist
    In the 2nd view ONLY we have General individual screen in that we have
                    1) confirm type : choices are Partial / Full confirmation
                    2) Goods movement : If the indicator is set the system will give log screen message and ask you to say Y or N to correct the errors in goods movement
                 An other indicator for Quantity / activity as  control indicator
                 I think this will help
         Regards,
         Raj

  • Check of operation sequence in order

    Hi all,
    I don't want to check of operation sequence in order. so  how can I do this? Are there any customizing for this case?
    Best regards,
    Hilal Çakır
    email : [email protected]

    Make the following changes in control key or use the control key which have this setting
    In OPJ8, for a control key
    Confirmation = Confirmation possible but not necessary
    In OPK4, for a plantb and production order type combination in Generally valid settings tab page -
    Checks sub page
    operation sequence = set operation sequence is not checked
    With this setting  it will work

  • Operation sequence

    Hi, my operation sequence is mix of std and parellel, how to maintain the same thru ca01? when i click on sequence, always std is appearing and it is grade out, not changable. how to select diffenrt seq like parallel or alternative>?

    Dear Yadav,
    Plz refer this link
    [Routing;
    Regards
    kumar

  • Operation sequence restriction in CO19

    Dear Guys,
                We have 5 operations (10,20,30,40,50) for an material. I already assigned the value for confirmation field of control key "PP01" as "2 Confirmation required". But during production operation confirmation by using CO19, system allows user  to skip the operation confirmation process without confirming the previous operation. If i change the value of operation sequence as"Error when operation sequence is not adhered to" in "parameter for operation confirmation" screen, the  issue will be solved? what kind of values i want to set for this issue?
    current value as "operation sequence is not checked"
    Thanks

    Raja Sekaran wrote:
    If i change the value of operation sequence as"Error when operation sequence is not adhered to" in "parameter for operation confirmation" screen, the  issue will be solved? what kind of values i want to set for this issue?
    >
    > * current value as "operation sequence is not checked"
    >
    > Thanks
    yes, that setting in OPK4 should be enough.
    The following is the documentation
    Check of operation sequence in order
    Defines whether a system message is to be issued when the operation sequence is not adhered to and if so, which type of message.
    This key only applies to confirmations at operation level.
    Dependencies
    To find out whether the operation sequence has been adhered to, the following checks are carried out:
    Have preceding operations already been confirmed?
    Does the confirmed yield from the preceding operations exceed the total confirmed quantity of the operation to be confirmed?

  • The timeout period elapsed prior to completion of the operation or the server is not responding

    the timeout period elapsed prior to completion of the operation or the server is not responding.
    The error shows while executing a (select query) telerik report in MVC.

    Hello,
    Did you set the CommandTimeOut property of the SQL Command when you call the connection string to SQL Server?
    If your select query is complex or the data is larger, please try to specify connectiontimeout property to maximum integer value.
    Regards,
    Fanny Liu
    Fanny Liu
    TechNet Community Support

  • TCP Provider: An operation on a socket could not be performed because the system lacked sufficient buffer space or because a queue was full.

    Hi All,
    We have snapshot replication . Job is failing in between due to below error.
    Error messages:
    The process could not connect to Subscriber 'XX:SD'. (Source: MSSQL_REPL, Error number: MSSQL_REPL20084)
    Get help: http://help/MSSQL_REPL20084
    TCP Provider: An operation on a socket could not be performed because the system lacked sufficient buffer space or because a queue was full. (Source: MSSQLServer, Error number: 10055)
    Get help: http://help/10055
    A network-related or instance-specific error has occurred while establishing a connection to SQL Server. Server is not found or not accessible. Check if instance name is correct and if SQL Server is configured to allow remote connections. For more information
    see SQL Server Books Online. (Source: MSSQLServer, Error number: 10055)
    Get help: http://help/10055
    Login timeout expired (Source: MSSQLServer, Error number: HYT00)
    Get help: http://help/HYT00
    Please suggest

    Hi Khushi,
    According to your description, your snapshot replication job fails and you come across the error related to TCP Provider. Based on my research, the issue could occur as the following two situations.
    1. OS runs out of memory for TCP buffers. When people use the two switch: the /PAE switch in the c:\boot.ini file and the /3gb switch in the boot.ini file. If the applications require many OS resources, such as by opening many TCP connections, this can cause
    the OS to run out of memory for resources like TCP buffers.
    2.OS runs out of available TCP “ephemeral” ports. When the client machine is opening many TCP connections and is running Windows Server 2003, Windows XP, or any earlier version of Windows, it may run out of TCP “ephemeral” ports.
    To work around the issue, please follow the two solutions as below.
    1.Remove the /3gb switch from c:\boot.ini. The root problem in this case is memory pressure on the OS, so removing the /3gb switch will give more memory to the OS and will alleviate this problem.
    2.Make more ephemeral ports available following the steps in the article:
    http://support.microsoft.com/kb/196271
    For more information about the process, please refer to the article:
    http://blogs.msdn.com/b/sql_protocols/archive/2009/03/09/understanding-the-error-an-operation-on-a-socket-could-not-be-performed-because-the-system-lacked-sufficient-buffer-space-or-because-a-queue-was-full.aspx
    Regards,
    Michelle Li

  • SCOM 2012 R2 installing on SQL 2012 SP1 - Error Code: 0x80131904, Exception.Message: Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding.

    Hi,
    I am getting an issue during a SCOM 2012 R2 installation while creating the SCOM DataWarehouse database. Setup seems to timeout during creating the datawarehouse database. I can see all database files created in windows explorer on the SQL server before
    setup rolls the SCOM install back.
    Has anyone seen this issue before or know how to help resolve it?
    Appreciate your help, below is the SCOM installation log:
    Thanks
    Marc
    [13:27:27]: Always: :Creating Database: OperationsManagerDW
    [13:35:28]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [13:43:28]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [13:51:29]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [13:59:30]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:07:30]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:15:31]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:23:31]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:31:32]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:39:32]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:47:33]: Warn: :Warning:Retry on SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:55:33]: Error: :DB operations failed with SQL error -2: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    : Threw Exception.Type: System.Data.SqlClient.SqlException, Exception Error Code: 0x80131904, Exception.Message: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:55:33]: Error: :StackTrace:   at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection, Action`1 wrapCloseInAction)
       at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj, Boolean callerHasConnectionLock, Boolean asyncClose)
       at System.Data.SqlClient.TdsParser.TryRun(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj, Boolean& dataReady)
       at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString)
       at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async, Int32 timeout, Task& task, Boolean asyncWrite, SqlDataReader ds)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, TaskCompletionSource`1 completion, Int32 timeout, Task& task, Boolean asyncWrite)
       at System.Data.SqlClient.SqlCommand.InternalExecuteNonQuery(TaskCompletionSource`1 completion, String methodName, Boolean sendToPipe, Int32 timeout, Boolean asyncWrite)
       at System.Data.SqlClient.SqlCommand.ExecuteNonQuery()
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SqlRetryHandler.ExecuteNonQuery(SqlCommand sqlCommand, Int32& result)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SqlRetryHandler.Execute[T](SqlCommand sqlCommand, SqlRetryPolicy retryPolicy, GenericExecute`1 genericExecute)
    [14:55:33]: Error: :Inner Exception.Type: System.ComponentModel.Win32Exception, Exception Error Code: 0x80131904, Exception.Message: The wait operation timed out
    [14:55:33]: Error: :InnerException.StackTrace:
    [14:55:33]: Error: :Error:Failed to execute sql command. Setup has reached maximum retry limit.
    [14:55:33]: Warn: :Sql error: 11. Error: -2. Error Message: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:55:33]: Error: :Exception running sql string
    DECLARE @sql NVARCHAR(MAX);
    SET @sql = 'CREATE DATABASE ' + QUOTENAME(@DatabaseName) + '
        ON PRIMARY(NAME=MOM_DATA,FILENAME=''' + REPLACE(@Filename, '''', '''''') + ''',SIZE=' + CAST(@Size AS VARCHAR) + 'MB,MAXSIZE=UNLIMITED,FILEGROWTH=' + CAST(@FileGrowth AS VARCHAR) + 'MB)
        LOG ON(NAME=MOM_LOG, FILENAME=''' + REPLACE(@LogFilename, '''', '''''') + ''',SIZE=' + CAST(@LogSize AS VARCHAR) + 'MB,MAXSIZE=UNLIMITED,FILEGROWTH=' + CAST(@LogFileGrowth AS VARCHAR) + 'MB)';
    EXEC(@sql);: Threw Exception.Type: System.Data.SqlClient.SqlException, Exception Error Code: 0x80131904, Exception.Message: Timeout expired.  The timeout period elapsed prior to completion of the operation or the server is not responding.
    [14:55:33]: Error: :StackTrace:   at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection, Action`1 wrapCloseInAction)
       at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj, Boolean callerHasConnectionLock, Boolean asyncClose)
       at System.Data.SqlClient.TdsParser.TryRun(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj, Boolean& dataReady)
       at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString)
       at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async, Int32 timeout, Task& task, Boolean asyncWrite, SqlDataReader ds)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, TaskCompletionSource`1 completion, Int32 timeout, Task& task, Boolean asyncWrite)
       at System.Data.SqlClient.SqlCommand.InternalExecuteNonQuery(TaskCompletionSource`1 completion, String methodName, Boolean sendToPipe, Int32 timeout, Boolean asyncWrite)
       at System.Data.SqlClient.SqlCommand.ExecuteNonQuery()
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SqlRetryHandler.ExecuteNonQuery(SqlCommand sqlCommand, Int32& result)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SqlRetryHandler.Execute[T](SqlCommand sqlCommand, SqlRetryPolicy retryPolicy, GenericExecute`1 genericExecute)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.DBConfigurationHelper.DBConfiguration.RunSqlCommandsList(IEnumerable`1 sqlCommands)
    [14:55:33]: Error: :Inner Exception.Type: System.ComponentModel.Win32Exception, Exception Error Code: 0x80131904, Exception.Message: The wait operation timed out
    [14:55:33]: Error: :InnerException.StackTrace:
    [14:55:33]: Always: :Failed to create and configure the DB with exception.: Threw Exception.Type: System.Data.SqlClient.SqlException, Exception Error Code: 0x80131904, Exception.Message: Timeout expired.  The timeout period elapsed prior to completion
    of the operation or the server is not responding.
    [14:55:33]: Always: :StackTrace:   at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection, Action`1 wrapCloseInAction)
       at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj, Boolean callerHasConnectionLock, Boolean asyncClose)
       at System.Data.SqlClient.TdsParser.TryRun(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj, Boolean& dataReady)
       at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString)
       at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async, Int32 timeout, Task& task, Boolean asyncWrite, SqlDataReader ds)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, TaskCompletionSource`1 completion, Int32 timeout, Task& task, Boolean asyncWrite)
       at System.Data.SqlClient.SqlCommand.InternalExecuteNonQuery(TaskCompletionSource`1 completion, String methodName, Boolean sendToPipe, Int32 timeout, Boolean asyncWrite)
       at System.Data.SqlClient.SqlCommand.ExecuteNonQuery()
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SqlRetryHandler.ExecuteNonQuery(SqlCommand sqlCommand, Int32& result)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SqlRetryHandler.Execute[T](SqlCommand sqlCommand, SqlRetryPolicy retryPolicy, GenericExecute`1 genericExecute)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.DBConfigurationHelper.DBConfiguration.RunSqlCommandsList(IEnumerable`1 sqlCommands)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.DWConfigurationHelper.DWConfigurationProcessor.RunAdminScripts(String sqlServerInstance, Nullable`1 port, String databaseName, Int64 dbSize, Int64 logSize, String dbPath, String logPath)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.DWConfigurationHelper.DWConfigurationProcessor.ConfigureDataWarehouseDatabase(String sqlServerInstance, Nullable`1 port, String databaseName, Int64 dbSize, Int64 logSize, String dbPath,
    String logPath)
    [14:55:33]: Always: :Inner Exception.Type: System.ComponentModel.Win32Exception, Exception Error Code: 0x80131904, Exception.Message: The wait operation timed out
    [14:55:33]: Always: :InnerException.StackTrace:
    [14:55:33]: Error: :CreateDataWarehouse failed: Threw Exception.Type: System.Data.SqlClient.SqlException, Exception Error Code: 0x80131904, Exception.Message: Timeout expired.  The timeout period elapsed prior to completion of the operation or
    the server is not responding.
    [14:55:33]: Error: :StackTrace:   at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection, Action`1 wrapCloseInAction)
       at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj, Boolean callerHasConnectionLock, Boolean asyncClose)
       at System.Data.SqlClient.TdsParser.TryRun(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj, Boolean& dataReady)
       at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString)
       at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async, Int32 timeout, Task& task, Boolean asyncWrite, SqlDataReader ds)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, TaskCompletionSource`1 completion, Int32 timeout, Task& task, Boolean asyncWrite)
       at System.Data.SqlClient.SqlCommand.InternalExecuteNonQuery(TaskCompletionSource`1 completion, String methodName, Boolean sendToPipe, Int32 timeout, Boolean asyncWrite)
       at System.Data.SqlClient.SqlCommand.ExecuteNonQuery()
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SqlRetryHandler.ExecuteNonQuery(SqlCommand sqlCommand, Int32& result)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SqlRetryHandler.Execute[T](SqlCommand sqlCommand, SqlRetryPolicy retryPolicy, GenericExecute`1 genericExecute)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.DBConfigurationHelper.DBConfiguration.RunSqlCommandsList(IEnumerable`1 sqlCommands)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.DWConfigurationHelper.DWConfigurationProcessor.RunAdminScripts(String sqlServerInstance, Nullable`1 port, String databaseName, Int64 dbSize, Int64 logSize, String dbPath, String logPath)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.DWConfigurationHelper.DWConfigurationProcessor.ConfigureDataWarehouseDatabase(String sqlServerInstance, Nullable`1 port, String databaseName, Int64 dbSize, Int64 logSize, String dbPath,
    String logPath)
       at Microsoft.SystemCenter.Essentials.SetupFramework.InstallItemsDelegates.OMDataWarehouseProcessor.CreateDataWarehouse()
    [14:55:33]: Error: :Inner Exception.Type: System.ComponentModel.Win32Exception, Exception Error Code: 0x80131904, Exception.Message: The wait operation timed out
    [14:55:33]: Error: :InnerException.StackTrace:
    [14:55:33]: Error: :FATAL ACTION: CreateDataWarehouse
    [14:55:33]: Error: :FATAL ACTION: DWInstallActionsPostProcessor
    [14:55:33]: Error: :ProcessInstalls: Running the PostProcessDelegate returned false.
    [14:55:33]: Always: :SetErrorType: Setting VitalFailure. currentInstallItem: Data Warehouse Configuration
    [14:55:33]: Error: :ProcessInstalls: Running the PostProcessDelegate for OMDATAWAREHOUSE failed.... This is a fatal item.  Setting rollback.
    marc nalder

    Hi,
    Based on the log, I recommend you use the following way to test SQL connectivity.
    You can use a UDL file to test various connectivity scenarios, create a simple text file, rename the extension from TXT to UDL, fill out the necessary information on the connection tab then test the connection, and troubleshoot as necessary
    if it fails to connect.
    For more information, please review the link below:
    The easy way to test SQL connectivity
    http://blogs.technet.com/b/michaelgriswold/archive/2014/01/06/the-easy-way-to-test-sql-connectivity.aspx
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Export (not schedule) Webi as PDF

    Hello,
    I found code snippets to export (not schedule) an existing Crystal Report to PDF.
    However, I could not find a similar code snippet or documentation for Webi. I would like to export an existing Webi instance (managed) to PDF. I do not want to schedule the Webi because I need to preserve the data contained in that instance. I am trying to mimick the "Save to my Computer as..." functionality of Webi XI R2, but without the need to open/view the report.
    Please point me in the proper direction. I have browsed through the Report Engine API but could not relevant information.
    Thank you

    Towards the end of page at following link
    http://devlibrary.businessobjects.com/BusinessObjectsXIR2SP2/en/en/RE_SDK/resdk_dg_doc/doc/resdk_net_CustoWebI_dg/ewucw_053.html#1037054
    shows how to view a report in Xls, you can change OutputFormatType to PDF to view a report in Adobe. From Adobe it can be saved to local computer.

  • Could not complete this operation the. File was not found.

    I am running Illustrator CS6 on a Mac version 10.9.1. My problem is that when I try to "Save for Web" I get an error message of:
    "Could not complete this operation the. File was not found."
    What is it even talking about?!? It can save it normally, but not as a .jpg, .png, etc.
    I just restarted the program (but this isn't the first time I received this error). Now it says something new:
    Some names of the files being saved contain non-Latic characters. These file names will be incompatible with some Web browsers and servers.
    I simply named the file "6.png"
    That time it did allow me to save though. What is going on!??

    +1
    I am getting the same error message for "Save for Web" on Adobe Illustrator CS6 on my Macbook Pro Version 10.10
    "Could not complete this operation the. File was not found."
    Frustrating

  • Operation ' Change Attribute TSTATE ' could not be carried out for Request

    hi,
    i am unable to delete the request Id  from  DSO. and when i checked that, it says request is partially activated(error occured during the activation)
    and when i checked the logs i got the following error messages:
    Operation ' Change Attribute TSTATE ' could not be carried out for Request 609249
    Termination in problem report 'RSS2_DTP_RNR_SUBSEQ_PROC_SET' in row '      361'
    i even thought it was BASIS issue but it was not.
    due to this error the process chain is failing daily
    kindly help
    regards
    laksh

    hi arvind,
    i tried using the both the methods you had mentioned, i am able to delete the request at that moment but its again coming back, i think as it is a partially activated request so may be that is why it is happening
    but the problem is still there
    regards
    Laksh

  • Operation ' Change Attribute TSTATE ' could not be carried out

    Hi All,
    When I attempt to compress an infocube I get the following error messages:
    @5C\QError@     Operation ' Change Attribute TSTATE ' could not be carried out for Request 1114486
    @5C\QError@     Termination in problem report 'RSS2_DTP_RNR_SUBSEQ_PROC_SET' in row '255'
    I checked the request 1114486 in infocube and saw that its status is green however the overall status in the load monitor was "deleted".
    How can I fix the problem with this request ?
    It is a very old request and it was already uploaded to several other targets.
    Thanks in advance..
    Berna

    hi,
    It can be due to large data volume which might require more system resources then usual, see if there is any dump related to this in ST22, Also check whether any request is currently running on cubefor data  loaded to cubeor getting load to further targets
    try compression for less requests say 3 or 4, see if it works or not
    hope it helps
    regards
    laksh

Maybe you are looking for

  • Delete Email from Server... or Not...

    I have yet to see a single person raise the same challenge I am having with email. So, I suspect there must be a feature I am not configuring properly... or something. I have configured a POP email account. I want to be able to delete from the server

  • Need to upgrade from iTunes 5 to 7, but must uninstall first...

    Is my music library (playlists and all) going to be safe when I delete the old version? I can't load the new version until I delete the old, according to the prompt I get when I try to upgrade. I am dusting off my early generation iPod and starting u

  • Backing up macbook pro to time capsule for first time via ethernet

    I set up a new 2T Time Capsule / Airport, let it run overnight, only about half way backed up.  I deleted first backup file, and want to do the backup via ethernet.  How do I do this?

  • Sort datagrid column in groupby

    Hai   can any one help to sort the advanced datagrid column in ascending   by default the values will be in groupby format..   how to sort in groupby... Thanks in Advance

  • Loading frames before images (preloader question)

    I've got an .swf of which is 83% images and weighs ~4mb. For that big size I decided I would do an preloader, however, the preloader's frame will only load after images and other resources are loaded. Basically, the preloader will only appear after 8