Output control and outbound parameters

Can you please help me locate the output control and outbound parameters...
thank you in advance...

Hi Pabito,
              I am assuming that you need to send an outgoing EDI - Mail or fax to a specific partner. This process is possbile if you could set up the output control for sales  documents.
spro->sales & distribution -> BF -> Output control-> output determination -> maintain output determination for sales documents -> Assign output types to partner function.
Make sure that an output determination procedure is assigned to the sales dco type.
Also Maintain condition records for the output type and the transmission medium(EDI) using the trx NACE.
I hope this is what you are looking for, i also have a faint notion that you might be lookin how to setup an edi connection with the partner.!!!
If my notion is right do ping back to know more abt that,If you find this piece of information do take some time to award points to mee
- Girish

Similar Messages

  • Output control and message types

    Hi guys,
    my problem is this:I have created a new message type for output control for Purchase Order but when I create a new PO and click on 'messages'  I expect that the new message type appear as a DEFAULT for example other messages like NEU,etc....
    Customizing is OK--> I have parametrized the tr.NACE in all points and also Message Determination Schemas...What can I do?Is there a way to set message types as a DEFAULT for Output control  in Purchase Order?
    Thanks in advance,10 points for a resolutive answer...
    Bye
    Maximilian

    HI
    I assume that you have created a new message type by cpoying a standard.
    Basic:
    You need to maintain access sequence, form routine, forms.. for this output types (which should not be a problem if you are copying from std.)
    Important:
    You also need to maintain the Fine- tuned control for message type, for  the new output type.
    You need to add your new output type in the output determination schema.
    then the thing should work. try!
    MRao.

  • Output Control and Copy Control

    I have the following problem.
    My client has a copy control for transfering data from a quotation to a different type of quotation. The quotation (old one) has a sold-to-party and a ship-to-party. These two partners are copied to the new quotation. If for any reason the ship - to - party is changed, then while printing an output for the quotation, the old ship - to - part is being printed.
    What should I do?

    Hi Stilianos,
    Please go to NACE t-code and check your output condition records regarding of your access sequence and output type.  condition record may effect your ship-to  like your problem.
    Moreover, check your routines maintained properly your copy control partner item routine and copying requirement to your copy control item level from SD>Sales and distribution>Sales>Maintain Copy Control for Sales Documents > Copying control: Sales doc to sales doc.
    I hope these will be helpful for your issue. Additionally, please share with us the progress about it.
    Regards,
    Sinan

  • Paging control and URL parameters

    Hi there,
    Please check out this page:
    http://martinique.org/activities/sports.php
    Go to the section "Skiing Surfing"
    1 - Use the navigation to go through the records.
    2 - Take a look at the URL in the browser window.
    Now, please go to the section "Hiking" and repeat 1 & 2.
    Note that the URL is appending the new parameters instead of replacing the previous one.
    What am I doing wrong here.
    Please help me to solve this problem.
    Thank you much!

    The code generated by the Dreamweaver recordset navigation bar automatically adds any existing variables to the end of the query string. The following code (just above the DOCTYPE) comes from a recordset navigation bar on one of my pages:
    $queryString_listAuthors = "";
    if (!empty($_SERVER['QUERY_STRING'])) {
      $params = explode("&", $_SERVER['QUERY_STRING']);
      $newParams = array();
      foreach ($params as $param) {
        if (stristr($param, "pageNum_listAuthors") == false &&
            stristr($param, "totalRows_listAuthors") == false) {
          array_push($newParams, $param);
      if (count($newParams) != 0) {
        $queryString_listAuthors = "&" . htmlentities(implode("&", $newParams));
    $queryString_listAuthors = sprintf("&totalRows_listAuthors=%d%s", $totalRows_listAuthors, $queryString_listAuthors);
    I haven't tested this, but to eliminate the extra variables in the query string, comment out the whole of the if statement like this:
    $queryString_listAuthors = "";
    if (!empty($_SERVER['QUERY_STRING'])) {
      $params = explode("&", $_SERVER['QUERY_STRING']);
      $newParams = array();
      foreach ($params as $param) {
        if (stristr($param, "pageNum_listAuthors") == false &&
            stristr($param, "totalRows_listAuthors") == false) {
          array_push($newParams, $param);
      if (count($newParams) != 0) {
        $queryString_listAuthors = "&" . htmlentities(implode("&", $newParams));
    $queryString_listAuthors = sprintf("&totalRows_listAuthors=%d%s", $totalRows_listAuthors, $queryString_listAuthors);
    You will need to do that for each of your recordset navigation bars.

  • How to understand "outbound parameters" and "inbound parameters" in WE20?

    Hi,
    How to understand "outbound parameters" and "inbound parameters" in transaction code:WE20? Which side is based to set the outbound/inbound parameters?
    As I can only set "outbound parameters" for the both partner type:customer and vendor.
    so, When do we need to set the parameter "inbound parameter"?
    Thanks.

    Hi,
    If you deals with inbound IDoc processing then you need only to maintain partner profile for inbound parameter.
    However, if you deal with outbound IDoc processing then you need to setup partner profile for outbound parameter.
    In special case, you may need to setup both inbound and outbound parameters for example the sender needs to have confirmation or acknowledgement for completion of inbound IDoc processing.
    Please check this links and should help you to learn/start with ALE.
    http://help.sap.com/saphelp_erp2004/helpdata/en/dc/6b835943d711d1893e0000e8323c4f/content.htm
    http://www.sapgenie.com/sapgenie/docs/ale_scenario_development_procedure.doc
    Also you can check this online document for ALE and IDoc.
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/BCMIDALEIO/BCMIDALEIO.pdf
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/BCMIDALEPRO/BCMIDALEPRO.pdf
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/CABFAALEQS/CABFAALEQS.pdf
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/BCSRVEDISC/CAEDISCAP_STC.pdf
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/BCSRVEDI/CAEDI.pdf
    Hope this will help.
    Regards,
    Ferry Lianto
    Please reward points if helpful.

  • Problem of configuration the requirement output control ?

    Hi ,
    i am now in a very urgent situation that is the system does not create the message type after executing the transaction VL31N.
    In detail :
       I have used the transaction NACE to configure the "Requirements output control" and i have created 3 message type (Z1 , Z2, Z3)  ( type V6 : handling unit) and i have coded for each of them to check the requirements for creating the messsage type ( the message type will be created if the sy=subrc = 0 after the forms are executed.
    FORM KOBEV_Z1.
    Check condition from the structure  komkbv6
    if cond Ok
      sy-subrc = 0.
    endif.
    ENDFORM KOBEV_Z1.
      FORM KOBEV_Z2.
    Check condition from the structure  komkbv6
    if cond Ok
      sy-subrc = 0.
    endif.
      ENDFORM KOBEV_Z2.
      FORM KOBEV_Z3.
    Check condition from the structure  komkbv6
    if cond Ok
      sy-subrc = 0.
    endif.
      ENDFORM KOBEV_Z3.
    But in fact , even if i have put the sy-subrc = 0 for each of them or for all , the message type was not created as i need .
    Result :
      if the message type is created automatically after executing the KOBEV or KOBEV , a printing program will be called to print the SAPscript form , but till now , i can not do that , to print the form i have to created the message type by hand ..
    Is the something wrong in the system ? How can i configure them to run well ?
    Please help me .
    PS : I will reward immediately and i am waiting
    Thank you very much

    Hi,
    If you are supposed to bring across characteristic values to your target, then you will not be able to jump from the result line. The configuration expects that the values of the characteristic marked as being used in the jump are filled with unique values. When you use the result line as a source for your jump, the values in the result line will most likely be based on the sum of multiple characteristic values.
    Hth,
    -Jacob

  • Sales and distribution output control Help

    Dear gurus..
    I have made my customized Output type from
    IMG -> SD -> BASIC FUNCTION -> OUTPUT CONTROL -> OUTPUT DETERMINATION -> OUTPUT DETERMINATION USING THE CONDITION TECHNIQUE -> MAINTAIN OUTPUT DETERMINATION FOR SALES DOCUMENTS -> MAINTAIN OUTPUT TYPES.
    I have attached my program and form to the following parameters..
    But when i go to VA42 and enter details for the header ouput area i cant find my customized output type
    please help
    Regards
    Saad.Nisar

    Saad,
    It seems you didnt proper configured Output procedure.
    Please follow this step and check
    --> Go to transaction NACE to add your own output types.
    --> Goto transaction NACE and select the application type and Click on Output types button.
    --> Click on Change button and Select Processing routines and click on NewEntries button.
    --> Give the output type and Give your program and FORM routine and save it
    Check also u must have to put your new outut types into the procedure.
    Hope it will help.
    Thanks,
    Raja

  • Standard script and code for output control ticket in IW32

    Hi,
    I am working on a output control ticket which gets printed using transaction IW32.
    I have to create Z driver program and z form and attach it to shop paper.
    I just wanted to make sure that RIPRCT00 and PM_COMMON are the standard program and form for this output control ticket.
    Because even though if I keep a break point in the program RIPRCT00 to see the data its fetching, when I do the print preview after going in IW32 I don't go inside the standard program RIPRCT00.
    So I am wondering if RIPRCT00 and PM_COMMON are the standard prohgram and form attcahed with output control ticket ?

    You must enter something in the form.  The reason for this is because in the program when it is going to execute the print of the papers, it is call the subroutine(form) of the print program.  It gets these values from your configuration in SPRO.  It is doing something like this.
    perform print_paper in program zriprct00.
    Of course, "print_paper"  and "zriprct00" are variables retrieved from the configuration.
    So, in summary,  In SPRO,  configure the output type to use the PRINT_PAPER form of program "ZRIPRCT00" and the sapscript form ZPM_COMMON. 
    If you are developing a completely new "Z" print program, you must have an entry point in which the program is executed.  You will have to have a subroutine(form) very simular to PRINT_PAPER,  or you can just copy and paste that code into your new program. 
    Make sense?
    Regards,
    Rich Heilman

  • SharePoint DateTime Control "Hour, Minute, and Second parameters describe an un-representable DateTime"

    I am facing a strange behavior from SharePoint:DateTime control.
    I have a webpart containing couple of fields along with datetime control. If I leave this page inactive for a while and then click submit, an exception is thrown stating that "Hour, Minute, and Second parameters describe an un-representable DateTime". 

    Hi,
    According to your post, my understanding is that you got datetime control error.
    The problem may be lied in the Time component. You can disable the time component and go for a date only rendering of the control by setting
    DateTimeField.DateOnly = true.
    http://social.technet.microsoft.com/Forums/sharepoint/en-US/64c05363-fd7e-49bb-8239-c93ec78172b6/datetime-control-using-basefieldcontrol?forum=sharepointgeneralprevious
    what’s  more, you can the ULS log to see the details errors.
    For SharePoint 2013, by default, ULS log is at
    C:\Program Files\Common Files\Microsoft Shared\Web Server Extensions\15\LOGS
    Thanks & Regards,
    Jason
    Jason Guo
    TechNet Community Support

  • Need Help Audio Amplitude Output Controlling Multiple Parameters

    What I am trying to accomplish here is having one audio track effect multiple parameters, obviously all of the parameters would be slightly different so I'm not just making duplicates of one object.
    Anyways, is there a way to use the audio amplitude to effect multiple parameters. I want to only have to analyze the audio one time, and then have that analyzation control multiple things. I've tried a Rig, but that doesn't seem to give me the options I need to configure this.

    First of all, it doesn't "hurt" anything to have mulitple audio behaviors added to parameters. It doesn't duplicate the audio in any way. What IS the PITA, is you really have to wait for the audio behaviors to "process" (all the way to 100%) because if they're interupted, they'll often NOT finish creating the keyframes all the way to the end of the project.
    You can easily add Link Behaviors to anything that is already under audio pararmeter control. You can chain them indefinitely.
    However, one good example that might be coincidentally convenient is to create a Number Generator, turn off Animate and link the audio to the Value. Make sure, in the audio behavior to set the Scale value to the maximum value you will need (default is 1 and number values from 0 to 1 are not terribly useful for most things in Motion.)  You can subsequently link other parameters to the Number's Value (Object.Numbers.Value from the Source Parameter dropdown in the Link Behavior). You can use the Value offset and Scale parameters in the link behavior to "shape" the behavior for each subsequent parameter under control. The sometimes useful side effect is that you have a visual number to monitor (you can set its opacity to 0 to hide it for the final project appearance.)
    For the image below, I created two Number generators and linked the same audio file to each, setting the left number value to the Left Channel of the audio and the right number value to the Right Channel of the audio. I created a small rectangle and created two Replicators off of it (Shape: Rectangle/Tile Fill/Columns 1/Rows 15/ Origin Bottlom). I used Color Over Pattern to color the "audio meter" effect and a Sequence Replicator with an Opacity parameter, Sequencing To, Traversal Custom and to the Location parameter, I linked each back to the corresponding Number Value (Scaled to 100 for percent in the Audio behaviors). The Link behavior to each Location has the Value Offset set to -100 [location works from -100% to 0%].
    You could link any number of parameters to the Number Values, and not have the audio parameters re-analyze all the time.

  • Comparing switch control and switch output and setting switch control accordingly

    Hello,
            i am developing a GUI for a system which contains relays to control the motors. For the same purpose i am using switch control on my GUI to control these relays.when these relay  are turned ON by the switch control on my GUI, they give back status to the GUI, which i am displaying as a switch status .
    Now the switch control and switch status on GUI must be same every time so that user can know the actual state of relay and control it.
    Now i have a condition when i have already turned ON switch from my GUI but due to some reason (may be communication fault or anything else) rellay is not turned ON and i get status of relay as OFF on my switch indicator. So the situation is" the switch control is in ON state and switch indicator displays OFF state".  which is practically wrong.
    I want that in this case the GUI should detect the status of the switch indicator and if the switch control is not the same , the switch control should be set as per the switch indicator so that user can use the switch again to turn the switch ON

    Hello Mike,
                        Thanks for the response!!
    As i have described the situation above, in any case if switch control fails to send message to relay due to some hardware fault , in that case relays will be off and the switch on GUI will be ON , and user will think that the relay is ON.Which is false condition.
    i tried to use property value(signl)   to give back the status of switch indicator to the switch control.
    You can have a look at attached files which i have made as demo.
    Now the problem is when i run my GUI for the first time all the switch on the front panel are off by default which creates a conflict to control the switches.
    Besides i am unaware of the timing events and how to implement it in my application . It would be great if you could provide some more details about it.
    Thanks & Regards,
    Shivkant Paswan
    Attachments:
    switch control trial.zip ‏16 KB

  • Purchase Order Output Control

    Hi,
    I am trying to create an ORDERS05 IDoc when a PO is created and sent to a folder via EDI processing.
    Here are the steps I followed...
    1. Created RFC Destination for EDI Subsystem (TCP/IP connection)
    2. Created File port and included the RFC Destination in the Outbound trigger tab.
    3. Created partner profile (Vendor)
             a. Outbound parameters - message type ORDERS,
                      i. Outbound Options - receiver port - file port created in step 2
                                                    basic type - ORDERS05
                      ii. Message Control - Application - EF
                                                     Message Type - NEU
                                                     Process Code - ME10
    4. Create PO (ME21)
    when I look under Menu Header -> Messages it goes to a printer instead of the File Port I created.
    Am I missing a step? Please let me know.
    Thanks,
    Sneha

    Thanks Kalpanashri,
    I followed what you said and this is what I received...
    <i>Maintain outgoing EDI-connection data for partner 1002514
    Message no. VN032
    Diagnosis
    The system could not locate the EDI partner agreements (outbound) for partner 1002514.
    System response
    You cannot use transmission medium 'EDI' with this partner.
    Procedure
    Maintain the EDI partner agreements for partner 1002514. Make sure to create entries for output control as well as for outbound parameters.</i>

  • Degugging Inbound and Outbound idocs

    Hi friends,
    Can any one help me in debugging Inbound and outbound IDocs?
    1.I found the inbound FM using Tcode we19,clicked the inbound FM button and called it in the debugging mode.
      While debugging the Inbound FM iam nt able to figure out the actual problem.Is there any way to reach out the exact problem?
    2.How to find out the outbound Idoc FM and debug it?
    Your help is appreciated.
    Thanks in Advance.

    Hi,
    Inbound or Outbound IDoc processing FM can be found iin partner profiles(WE20).
    for Outbound: WE20 --> choose partner type --> Outbound parameters --> choose message type --> Message control Tab --> Double click on Process code to get the FM assigned.
    for inbound: WE20 --> choose partner type --> Inbound parameters --> choose message type --> inbound options --> Double click on Process code to get the FM assigned.
    For debugging, use Tcode WE15 for outbound, But before that u need to set the output type dispatch time as 1 (Send with periodically scheduled Job). Go to Output type assignment screen --> assign the output type --> choose further processing --> Set Dispatch time as 1 --> Save.
    Note: U need to keep the break point in the Outbound FM or exit if any before going to WE15 to debug from that point.
    Hope it helps,
    SG.

  • EDI output message for Outbound Deliv send with application own transaction

    Dear All,
    I encountering a problem with the output message "WSOR" via EDI.
    What i want:
           I would to configure this message output without the Dispatch time " 3: Send with application own transaction".
    What is encountering now:
          I have done the setting in "VV22" or VV21, with the conbination of Delivery type and Shipping point. and the setting is EDI with dispatch time 3: Send with application own transaction.
    But When i use ME2O to create the outbound delivery for subcontractor, the message output "WSOR" process automatically and the dispatch time is 4: Send immediately (When application save).
    Can anyone please advice me what are the setting or area that i need to check!!
    Thank you very much,
    Regards,
    Chee Wee

    Hi
    Try here...
    Logistics Execution -> Shipping -> Basic Shipping Functions -> Output Control -> Output Determination -> Maintain Output Determination for Outbound Deliveries
    Regards
    Eduardo

  • Distibution Model- Outbound parameters for message type could not be found

    Hi SRM Gurus,
                          Have you ever encountered this error while buidling Distribution model in BD64 -
    When I try to generate partner profile, I am getting this error-
    Outbound parameters for message type BBPCO BBPCO01 could not be created
    Partner not found in partner table
    This error is occuring for all message types.
    Please let me know the solution if anyone has encountered this error before.
    Thanks & Regards
    Kapil

    Hi
    Are you geting this error while generate partner profile?
    hope your sender and receiver logical system are correct.double check.
    VERSION 3
    OUTPUT MODE - tRANSFER idoc immediately option
    connectivity between both sytems are ok.
    did you save modelview ?
    now ports automatically created . check we21 ,we20..
    check your sm59 rfc destination? what type connection you made ? hope you maynot do mistake. howevercheck itup.
    ask basis consultant assistance why ports anot genrated for backend system after you executed
    tbd05 - do yo have entry ?
    regards
    muthu

Maybe you are looking for