PCIe 7852R and SCB-68 connectivi​ty

1) NI SCHC68-68-EPM compatable with this R series board to connect digital lines (connector 1 and 2) to SCB-68A? The recommended NI SHC-68-68-RDIO is only 1m and would be of great inconvenience.
2) I want to ultimately connect the PCIe 7852R card analog+digital inputs and outputs to BNC (50 Ohm) breakout box. Does the SCB-68A terminal block provide any advantages over using unterminated cable such as SCH-68-NT-S directly?
3) How would I go about impedance matching the I/O from the FPGA to the BNCs?
Thanks!

Hi pobedil,
1. The NI SCH-68-68-RDIO is the only supported cable for connectors 1 and 2 of the PCIe-7852R.  The cable was specifically designed for the high performance and bandwidth of the R Series cards, and the length of the cable is specific for the impedance matching.
2. The main benefit of using a terminal block such as the SCB-68A is its ready-to-use access to each of the cable's pins via screw terminals.  If you wanted to create your own harness for the pins, the unterminated cable would be fine, but it requires you to make your own custom wiring scheme.
3. Some basics on impedance matching can be found in the link below:
http://www.ni.com/white-paper/3475/en#toc3
Andrew T.
National Instruments

Similar Messages

  • NI PCI 6221 and SCB-68 and timer

    I'm using NI PCI 6221 and SCB-68.  Can I use timer with Single Two-Signal Edge-Separation Measurement. Is this type of measurement can be set with that hardware combination. I,m asking becouse when I,m using DAQ ASSISTANCE it pointing the pin name that doesn,t exist on the SCB-68.

    Hi Fazi,
    The SCB-68 has pinout labels for E-series DAQ cards while the NI PCI-6221 is one of the newer M-series DAQ cards.  The Single Two-Signal Edge-Separation Measurement you want to take is possible with your card.  Below is a KnowledgeBase article which gives the SCB-68 pinouts for M-series cards. Let me know if this fully answers your question or I assumed something wrong.
    SCB-68 Quick Reference Label for M Series
    Alex A.
    Applications Engineer

  • Connecting PCI-6035E and SCB-68 and control a laser to turn on/off

    I have connected SCB-68 to a 15pin cable and connected to a laser. From computer I have connected PCI-6035E board to SCB-68 to control a Laser to turn on and off from a LabVIEW program. I have connected PIN#, 6,7, 14 from SCB-68 to 15pin connecter cable, and I connected PCI-6035E board to SCB-68. My program is not turning on the laser.
    Solved!
    Go to Solution.

    dnchari:
    Thanks for the manual. Youll need to set up the jumpers for external modulation and laser enable as shown in section II of the manual.
    On you 15 pin connector you will need to wire pin 4 to pin 5. This will enable the laser. Later, once you can verify modulation, maybe we can use the DAQ card to control the on/off.
    You made mention of DACOUT0 and AOGND, these look like the signals you need to connect- DACOUT0 wired to pin 8 (EXT MOD) and AOGND to pin 7 (GND).
    NOTE: Looks like 0V into the laser is no power, 1.350V into it is full power, so do not exceed 1.350V when commanding the analog output voltage.
    Hopefully this should get you started. Wear the proper wavelength laser safety goggles.
    -AK2DM
    ~~~~~~~~~~~~~~~~~~~~~~~~~~
    "It’s the questions that drive us.”
    ~~~~~~~~~~~~~~~~~~~~~~~~~~

  • How can I configure NI PCI 6221 and DAQ SCB-68 for pressure sensors?

    Hello
    everybody,
    I am using the measuring board (NI PCI 6221) and DAQ
    SCB-68 for the data acquisition.
    With the DAQ-Assistant I created AI for the voltage of
    pressure sensors. In a big indicator panel from this DAQ-Assistant I see the
    voltage for both sensors in the correct size. But if I set sensors in the
    blockdiagramm to control the signals for sensor one I get a wrong voltage size
    and for sensor 2 nothing.
    How can I configure this data acquisition equipment to
    get the correct signals?
    Thanks a lot for your help.

    I do not know the type of sensor you are using. But pressure transducers may have a very low output voltage(in the mVolt range). They also need an excitation voltage. Here is an introduction. http://focus.ti.com.cn/cn/lit/an/sloa034/sloa034.pdfThen working with pressure sensors I always use 3 stages in the circuit.
    1 Instrumentation Amplifier as a preamp
    2 filterstage
    3 Final amp and output buffer
    (you may combine stage 2 and 3)
    Besides which, my opinion is that Express VIs Carthage must be destroyed deleted
    (Sorry no Labview "brag list" so far)

  • PCIe 7842r to SCB-68A

    Hi,
    I have brought a PCIe 7842r, and it comes with the SCB 68A as the connector block.
    I wanna use the connector block for analog input and digital output, so I connected the pin68 and pin 67 with two wires. The pin 68 and pin 67 on SCB68A corresponds to the AI+ and AI- on the PCIe 7842r too, so it fits perfectly.
    Next step,  I want to use the PCIe 7842r to make a digital output, and I plan to use pin 36 and pin 2, which corresponds to DIO0 and DGND.
    However, the pin 36 and pin2 on the SCB68A is DGND and PFI14, which doesnt match with the output from the PCIe 7842r.
    Is there any suggestion for tackling this problem?
    Best,
    Matthew
    Solved!
    Go to Solution.

    MatthewTang wrote:
    On page 9, you have to magnify that to see the label
    If you look at the label on that page closely, you will see that it is for M and X Series DAQ Devices.  You should read the section on using the SCB-68A as a Direct Feedthough (page 14) and use the label I linked to eariler for your R Series card.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Sharing an external sample clock between PCI-6722 and PCI-6602

        I need PCI-6602 work with PCI-6722。6602 shares 6722’s ao/SampleClock as external clock and triggered by 6722’s ao/StartTrigger。The master device is 6722, which refered as Dev1, and the slave device is 6602, which refered as Dev2. A RTSI line is used to connect the two devices correctly.
        I use C API to finish my program and my code is as follows:
    //config 6722 analog out task
    1、DAQmxCreateTask("NI6672", &hAOTask);
    2、DAQmxCreateAOVoltageChan(hAOTask, "Dev1/ao0", "", -10.0, 10.0, DAQmx_Val_Volts, "" );
    3、DAQmxCfgSampClkTiming(hAOTask, "", 1000.0, DAQmx_Val_Rising, DAQmx_Val_ContSamps, 1000);
    4、DAQmxWriteAnalogF64(hAOTask, 1000, 0, 10.0, DAQmx_Val_GroupByChannel, data, NULL, NULL);
    //config 6602 counter task
    5、DAQmxCreateTask("NI6602", &hCounterTask);
    6、DAQmxCreateCICountEdgesChan(hCounterTask, "Dev2/ctr0", "", DAQmx_Val_Rising, 0, DAQmx_Val_CountUp);
    //use /Dev1/ao/SampleClock for external clock
    7、DAQmxCfgSampClkTiming(hCounterTask, "/Dev1/ao/SampleClock", 1000.0, DAQmx_Val_Rising, DAQmx_Val_ContSamps, 1000);
    //use /Dev1/ao/StartTrigger
    8、DAQmxSetTrigAttribute (hCounterTask, DAQmx_ArmStartTrig_Type, DAQmx_Val_DigEdge);
    9、DAQmxSetTrigAttribute (hCounterTask, DAQmx_DigEdge_ArmStartTrig_Src, "/Dev1/ao/StartTrigger");
    10、DAQmxSetTrigAttribute (hCounterTask, DAQmx_DigEdge_ArmStartTrig_Edge, DAQmx_Val_Rising);
    //start counter task first
    11、DAQmxStartTask(hCounterTask);
    //start 6722 task
    12、DAQmxStartTask(hAOTask);
    I run it on the MAX virtual Device, and the Step 11always returned -89120。
    I try to slove this problem, so I change the Step 7, use /Dev2/PFI9 to instead of /Dev1/ao/SampleClock.
    7、DAQmxCfgSampClkTiming(hCounterTask, "/Dev2/PFI9", 1000.0, DAQmx_Val_Rising, DAQmx_Val_ContSamps, 1000);
    The code runs well, but I don’t know which terminal is connected by /Dev2/PFI9. Does it connect to /Dev1/ao/SampleClock?
    I use another API DAQmxConnectTerms to ensure that, I add a Step before Step 11.
    DAQmxConnectTerms( "/Dev1/ao/SampleClock", "/Dev2/PFI9", DAQmx_Val_DoNotInvertPolarity );
    The program also run well. But I am still not sure that 6602 is sharing /Dev1/ao/SampleClock。If not, which terminal of Dev1 is connected by /Dev2/PFI9?
    Is my code right? If not, hwo to fix my code or supply some example for me? Thanks.

    Hello Shokey,
    From looking over your post, it looks like you want to program in C, using simulated instruments, a master/slave design with a PCI-6602 and PCI-6722. The PCI-6722 is the master device and the PCI-6602 is the slave device. In order to implement this with the real cards, you would need a RTSI cable between the 2 cards in order to pass the triggers and the sample clock. Unfortunately with simulated devices you can't implement this so parts of your code won't be able to work exactly like if you had the instrument.
    If you did have the instrument, you can implement this by performing the following steps:
    Master Device:
    1.) Export the ao/SampleClock and ao/StartTrigger to a RTSI Line. (See DAQmx C Reference help for DAQmxExportSignal to export these)
    Slave Device:
    1.) Set the Sample clock and the trigger to the RTSI.
    There is another forum that I think will help you out to implement this correctly. In this forum, the customer was trying to export a trigger through a RTSI and the problem he was experiencing was a broken RTSI cable. His code, he states, works. I hope this helps you with this and if you have any more questions, feel free to post.
    Jim St
    National Instruments
    RF Product Support Engineer

  • Connecting Yaskawa Sigma II Servo Drive (SGDH) to PCI-7344 and UMI-7774

    Hi,
    I have  NI PCI-7344 and UMI-7774 and i want to
    Connect the UMI-7774 to Yaskawa Sigma II Servo Drive (SGDH) , the servo motor drive is connected to the servo motor with original Yaskawa cables.
    1.  do you know if National instruments provide special cables to connect the UMI-7774 to the Yaskawa Sigma II Servo Drive (SGDH) ?
         i know there is special cable to connect this servo drive to the NI PCI-7390
         http://zone.ni.com/devzone/cda/tut/p/id/5908 
        (you can find in this link that this cable exist: 50 Pin cable for connecting MCA-7790Y to Yaskawa Sigma II Servo Amplifier)
         but this is not the case here, i need to connect the Servo Drive to the UMI-7774..
     2. Where can i find a tutorial on how to configure the PCI-7344 in MAX to send simple commands to the Servo Drive
          i.e.  to run the servo motor from position A to position B (10,000 encoder pulses)
    i'll be gratefull for any help
    Regards
    Moti

    Hi MotiM,
    We do not have a cable that will let you directly connect the UMI-7774 to a Yaskawa Drive.  We do sell cables that will have the Dsub connector to match the UMI-7774 with pigtails to wire to the drive.  If you take a look at the product page for the UMI-7774 you can see the different cables listed under the accessories.
    To perform a simple move in Measurement and Automation (MAX) is very simple.  In MAX under NI-Motion select your PCI-7344. Under this section select the settings option (by default it will be called Default 7340 settings).  Select the Servo radio button.  Initialize your controller.  Then you can select Interactive and 1-D Interactive and command your motor from there.  I have attached an image with the important areas highlighted for you. 
    Message Edited by Adam_H on 09-19-2008 03:41 PM
    Adam H
    National Instruments
    Applications Engineer
    Attachments:
    MAX.jpg ‏93 KB

  • Issue using PCIe-1430 and Magma ExpressBox1

    Hi - I'm trying to get my laptop working with the PCIe-1430 Camera Link frame grabber and the Magma ExpressBox1. The device shows up in the device manager twice, saying the drivers are installed but there are problems with the device. One device shows error code 10 ("This device cannot start."). The other shows error code 12 ("This device cannot find enough free resources that it can use (Code 12)     If you want to use this device, you will need to disable one of the other devices on this system."
    I've tried disabling one and the other PCIe-1430 devices, and I'm not sure what other devices I could try to disable. The computer has 3GB of RAM, so I'd doubt that's the problem. I've noticed that the board is PCIe x4 and the ExpressBox1 interface is x1, but since there is a bridge in between I assumed this would, at the worst, result in a lower maximum transfer rate. The Magma website mentions National Instruments boards in one of their case studies. Any ideas what may be causing this?
    Thanks

    Hi,
    I have been looking into this, and everyone I look the ExpressBox1 has only 1 PCI slot and it is x16.  Are you using a different version?  If it is only one PCI slot, then it should not show 2 devices in Windows.  Also how many PCIe-1430's are you trying to use?
    Regards,
    Greg H.
    Applications Engineer
    National Instruments

  • Measuring temperatur​e using thermocoup​le and SCB-68 box

    I used thermocouple and SCB-68 box to measure temperature. But the readings were fluctuating around the expected value. So I removed the thermocouple and short-circuited the differential input channels. As expected, the voltage reading was not zero and also fluctuating. It seems that there was something wrong with the SCB-68 box. What might lead to this and how to solve this problem? Thanks.

    The problem could be either the SCB-68 or the DAQ card you are using to make the measurement. You should first ensure that the DIP switches (S1 - S5) of your SCB-68 are in the correct position for your application. Please refer to the SCB-68 User Manual for more information on this subject.
    SCB-68 68-Pin Shielded Connector Block User Manual
    http://digital.ni.com/manuals.nsf/websearch/74C86A​DEF0E4813F86256C84007CB3AB?OpenDocument&node=1180_​US
    What do you mean by fluctuating? Full swings from 10V to 10V? Hitting one rail? Close to 0V but looks like noise in mV or uV? If your fluctuation is very slight, for example off by a few millivolts, than you could be picking up noise or your board could need to be calibrated. You can read more about accuracy and
    calibration from the following web page:
    Calibration Solutions from National Instruments
    http://www.ni.com/support/calibrat/
    If you have an E-Series Card you may be interested in running our Online E-Series Diagnostic Utility. This utility takes about 3 minutes to run, will perform a calibration, and will generate a report of anything that may be wrong with your board.
    Online E Series Diagnostic Utility
    http://www.ni.com/support/selftest/
    Regards,
    Justin Britten
    Applications Engineer
    National Instruments

  • How can i use PCIe 1433 and basler line camera to construct image and pocess it?

    hello! every one ,I am new to machine vision.i have two problems to ask.First,how can i use line camera and 1433 to acquire 2-D image?second,if i want to pocess the 1-D signal ,how can i do it ?i expect for your answer ,thank you!

    What you are trying to do is not something you can easily do in a forum, but I can give you the basics.
    You have a CameraLink frame Grabber (PCIe 1433) and a LineScan Camera
    The framegrabber needs to be configured to understand how to communicate with the camera.  You need a file from the camera vendor.  This file might already be installed.  You can use MAX to check if it is, under Devices/IMAQ.
    Assuming you can get to the point where you can communicate with the camera, you need to configure your acquisition.
    Since the camera is a line scan camera, it captures image data one pixel ine at a time.  You will need to configure the frame grabber to determine how many lines per image you want.  The low limit is usually 1, and the high limit is either based on the framegrabber's internal memory, or that of the computer.
    If you are using labview, you will need to open a sessing to the camera, acquire the image(s), and then close the session when you are done.
    Once the image(s) are captured, you can performa analysis using the NI Vision Toolkit.
    Sorry, but there is no way to condense years into one post.
    Machine Vision, Robotics, Embedded Systems, Surveillance
    www.movimed.com - Custom Imaging Solutions

  • Thermistor measurement using NI PCI-6036E and CB-68LP

    Hi everyone,
    I am quite new to LabVIEW and DAQ and I am in an attempt of performing temperature measurement using the only existing hardware available which are NI PCI-6036E and CB-68LP. I was in the attempt of trying to perform the example of temperature measurement based on a book by Robert H. King "Introduction to Data Acquisition with LabVIEW", but as I go further I realized that the hardware I have is totally different that the one in the book, as the one in the book can perform direct resistance measurement from the thermistor.
    I have learnt that there is a need of external excitation current needed but I am not sure of now to create one.
    Is it true that I need to do a lot of external circuitry in order for me to realize the temperature measurement with only PCI-6036E and CB-68LP? I don't have a budget to buy SCXI or BNC-2120 accessory.
    I bought a breadboard and a few resistors and connected to a voltage supply to build the external excitation but it failed miserably. 
    I am using Windows XP PC running LabVIEW 2011. 

    Hi Lynn,
    Thank you for your reply. I was just wondering at which terminal should I connect the AI0 of the DAQ card. I did the connection accordingly, by placing the external resistor in series with the thermistor. I connected the +5V source to one end of the external resistor and at the same point I place a connection to the AI0 and at the other end of the thermistor to the ground. The voltage seems to be a constant 5V.
    I wanted to monitor the change in temperature of the thermistor by monitoring the voltage variation. When I measure the voltage with an external multimeter there seems to be some changes in the voltage, from 4.51V to 4.54V when I place my thumb on the thermistor to give some heat. However, I couldn't monitor any variation with the VI on LabVIEW. Did I misconnected everything?
    I build the VI solely using DAQ Assistant to measure voltage.

  • How to add PCI 7340 and UMI in my labview program from functions palette or how?

    Am using PCI 7340 and UMI7764 for motion control of a stepper motor.
    How to add the functions for PCI and UMI in my labVIEW program and how
    do I use these further? I need to control the direction of stepper
    motor rotation based on the pressure applied which we calculate as
    either clock.anti clockwise. So which function palette should I use for
    that.
    We use a darlington pair driver unit. ? The output
    from UMI are from the individual axis control whereas the driver input
    is through a serial bus. So what kind of cable should we use to connect
    the UMI with this and how do we connect this or should we use any other
    driver unit? Please explain in detail.
     Thank you

    Thank you I ll see to it

  • Yellow mark - PCI Device" and "Network controller" on Satellite A100-787

    There is a yellow mark in the device manager for a driver called "PCI Device" and also for "Network controller" although the network connection (LAN) is working well and all other functions of the computer seem to be working well.
    What are those devices??

    Regarding the LAN driver, it is installed and working properly (the wired one). The wireless driver is provided by Atheros which I installed from its own setup file and it didnt give me any error so I assume it is installed well although I havent tested the wireless connection yet. I am going to do that shortly.
    As for the PCI device, the card reader is able to read Sony memory stick and one type of SD card with certain teeth arrangement but not another card with a different teeth type. I dont know why it is the case. so this remains a mistery to me.

  • PCI Device and Network Controller uninstalle​d

    Having problems with downloading a pci device and network controller driver for presario cq57? Need help. my hardware id is PCI\VEN_10EC&DEV_5209&SUBSYS_3577103C&REV_01 

    Hi:
    You need to install the Realtek Card Reader driver from your notebook's support and driver page for the PCI device.
    Please  do the following so I can find out what model wireless card your model uses...
    Go to the device manager, find the Other Devices category, and click on the Network Controller needing drivers.
    Then click on the Details tab at the top of the network controller window.
    Now you see a Property drop down list and it is defaulted to Device Description.
    Drop down on that and select the second item on the list (Hardware ID's).
    Post the top string of characters that begin with PCI\VEN.

  • Broken sound card, Can i install a pci card and get sound

    I fried my internal sound card plugging up my mixer through my headphone jack. I have a mirror door, dual 1 ghz prossesors. Can i just install a m-audio pci card and get my sound back. i hope so. thanks.

    The answer is yes, though there seems to be very few Mac compatible sound cards. This is probably because Macs always came with sound built in. The exceptions are the Xserve which have no sound section. I have a dual 1.33GHz G4 Xserve that I have fitted with a M-Audio Audiophile 192 PCI card. This works well but is expensive new (I got mine used). My only complaint (as a general purpose sound card) you have to use the M-Audio app to change the volume - the normal volume controls don't work.
    MUCH cheaper is the USB sound card option. I also have a Griffin iMic on my work Mac and this is plugged into my keyboard usb slot. That means I can conveniently plug my headphones in with just a short cord. Works great, sounds great, and works with the standard volume controls.

Maybe you are looking for