Plant can'be selected

Hi  expert
I create sto in system , the mateiral will be transfered from plant A to Plant B.
But when I input the material, It can't choose plant B, ( in seleted list , I can't see it)  but this part already maintained for plant B.
when I do standard Po, It could create Po which purchase from vendor A to plant B.
So what's the problem of this ?
Thanks
Alice

hi,
Did you maintain as follows:
1.SPRO >> IMg>>Materials Management >> Purchasing >> Purchase Order >> Set Up Stock Transport Order >> Assign Document Type, One-Step Procedure, Underdelivery Tolerance
here assign supplying plant as A
plant as B
and Doc type
2. 3.     On the Change View u201COrder Types for Stock Transport Orderu201D: Overview  screen, enter the following information:
supplying plant B
Plant As A
and doc. type...
SAVE it..
And then try again...
Regards
Priyanka.P

Similar Messages

  • How can I select 2 options in Interactive reports

    Hi Friends
    I have a doubt about Interactive reports/ ALV interactive reports. Is there any option to select multiple selections in interactive reports. If I am displaying in a screen CustNo, Name, Country.
    I want to see order details of that customer in another screen using AT Line-Selection. Can I select multiple customer nos at a time and also can I see those order details whom I selected over in first list.
    Please send me reply ASAP if there is any option with suitable example.
    Thanks
    Praveen.

    Check out this sample.  It uses two ALV grids.  On the first one you can do multiple selection, hit the continue buttons and it will throw another ALV with those material/plant records.  Implement the following program.  Create screen 100 and 200.  One each screen create a custom container called ALV_CONTAINER(screen 100) and ALV_CONTAINER2(screen 200).  Create the gui status for both.  Don't forget to create a "CONTINUE" button on the gui-status 100.
    report zrich_0006.
    tables: mara.
    type-pools: slis, icon.
    * Internal Tables
    data: begin of ialv occurs 0,
          matnr type mara-matnr,
          maktx type makt-maktx,
          end of ialv .
    data: begin of ialv2 occurs 0,
          matnr type mara-matnr,
          werks type marc-werks,
          end of ialv2.
    * Miscellanous Variables
    data: index_rows type lvc_t_row,
          index like line of index_rows.
    data: alv_container type ref to cl_gui_custom_container,
          alv_container2 type ref to cl_gui_custom_container,
          alv_grid type ref to cl_gui_alv_grid,
          alv_grid2 type ref to cl_gui_alv_grid,
          row_table type lvc_t_row with header line,
          ok_code like sy-ucomm,
          layout  type lvc_s_layo,
          fieldcat type lvc_t_fcat,
          fieldcat2 type lvc_t_fcat.
    select-options: s_matnr for mara-matnr.
    start-of-selection.
      select mara~matnr makt~maktx
                 into corresponding fields of table ialv
                     from mara
                          inner join makt
                             on mara~matnr = makt~matnr
                                    where mara~matnr in s_matnr
                                      and makt~spras = sy-langu.
      sort ialv ascending by matnr.
      call screen 100.
    *      Module  status_0100  OUTPUT
    module status_0100 output.
      set pf-status '0100'.
      set titlebar '0100'.
      data: lt_exclude type ui_functions.
    * Create Controls
      create object alv_container
             exporting container_name = 'ALV_CONTAINER'.
      create object alv_grid
             exporting  i_parent =  alv_container.
    *  Populate Field Catalog
      perform get_fieldcatalog.
    * Optionally restrict generic functions to 'change only'.
    * (The user shall not be able to add new lines).
      perform exclude_tb_functions changing lt_exclude.
    * Set selection mode to "D"  --  Multiple Lines
      layout-sel_mode = 'D'.
      call method alv_grid->set_table_for_first_display
          exporting
               is_layout              = layout
               it_toolbar_excluding   = lt_exclude
               i_structure_name       = 'IALV'
          changing
               it_outtab       = ialv[]
               it_fieldcatalog = fieldcat[].
    endmodule.
    *      Module  USER_COMMAND_0100  INPUT
    module user_command_0100 input.
      case sy-ucomm.
        when 'BACK' or 'CANC'.
          perform free_containers.
          if sy-subrc = 0.
            set screen 0.
            leave screen.
          else.
            leave program.
          endif.
        when 'EXIT'.
          perform free_containers.
          leave program.
        when 'CONTINUE'.
    * Retrieve selected rows from ALV grid
      clear index_rows.  refresh index_rows.
      call method alv_grid->get_selected_rows
               importing
                     et_index_rows = index_rows.
    * Do something with those selected rows here
          loop at index_rows into index.
            read table ialv index index-index.
            if sy-subrc = 0.
              select * appending corresponding fields of table ialv2
                           from marc
                               where matnr = ialv-matnr.
            endif.
          endloop.
          perform free_containers.
          leave to screen 200.
      endcase.
    endmodule.
    *      Form  FREE_CONTAINERS
    form free_containers.
      if not alv_container is initial.
        call method alv_container->free.
        clear: alv_container.
        free : alv_container.
      endif.
      if not alv_container2 is initial.
        call method alv_container2->free.
        clear: alv_container2.
        free : alv_container2.
      endif.
    endform.
    *      Form  Get_Fieldcatalog - Set Up Columns/Headers
    form get_fieldcatalog.
      data: ls_fcat type lvc_s_fcat.
      data: columnno(3) type n value '0'.
      refresh: fieldcat.
      clear: ls_fcat.
      ls_fcat-reptext    = 'Material Number'.
      ls_fcat-coltext    = 'Material Number'.
      ls_fcat-fieldname  = 'MATNR'.
      ls_fcat-ref_table  = 'IALV'.
      ls_fcat-outputlen  = '18'.
      ls_fcat-col_pos    = 1.
      append ls_fcat to fieldcat.
      clear: ls_fcat.
      ls_fcat-reptext    = 'Material Description'.
      ls_fcat-coltext    = 'Material Description'.
      ls_fcat-fieldname  = 'MATKX'.
      ls_fcat-ref_table  = 'IALV'.
      ls_fcat-outputlen  = '40'.
      ls_fcat-col_pos    = 2.
      append ls_fcat to fieldcat.
    endform.
    *      Form  Get_Fieldcatalog2 - Set Up Columns/Headers
    form get_fieldcatalog2.
      data: ls_fcat type lvc_s_fcat.
      data: columnno(3) type n value '0'.
      refresh: fieldcat2.
      clear: ls_fcat.
      ls_fcat-reptext    = 'Material Number'.
      ls_fcat-coltext    = 'Material Number'.
      ls_fcat-fieldname  = 'MATNR'.
      ls_fcat-ref_table  = 'IALV2'.
      ls_fcat-outputlen  = '18'.
      ls_fcat-col_pos    = 1.
      append ls_fcat to fieldcat2.
      clear: ls_fcat.
      ls_fcat-reptext    = 'Plant'.
      ls_fcat-coltext    = 'Plant'.
      ls_fcat-fieldname  = 'WERKS'.
      ls_fcat-ref_table  = 'IALV2'.
      ls_fcat-outputlen  = '4'.
      ls_fcat-col_pos    = 2.
      append ls_fcat to fieldcat2.
    endform.
    *      Form  EXCLUDE_TB_FUNCTIONS
    form exclude_tb_functions changing pt_exclude type ui_functions.
    * Only allow to change data not to create new entries (exclude
    * generic functions).
      data ls_exclude type ui_func.
      ls_exclude = cl_gui_alv_grid=>mc_fc_loc_copy_row.
      append ls_exclude to pt_exclude.
      ls_exclude = cl_gui_alv_grid=>mc_fc_loc_delete_row.
      append ls_exclude to pt_exclude.
      ls_exclude = cl_gui_alv_grid=>mc_fc_loc_append_row.
      append ls_exclude to pt_exclude.
      ls_exclude = cl_gui_alv_grid=>mc_fc_loc_insert_row.
      append ls_exclude to pt_exclude.
      ls_exclude = cl_gui_alv_grid=>mc_fc_loc_move_row.
      append ls_exclude to pt_exclude.
    endform.
    *      Module  status_0200  OUTPUT
    module status_0200 output.
      set pf-status '0200'.
      set titlebar '0200'.
    * Create Controls
      create object alv_container2
             exporting container_name = 'ALV_CONTAINER2'.
      create object alv_grid2
             exporting  i_parent =  alv_container2.
    *  Populate Field Catalog
      perform get_fieldcatalog2.
      call method alv_grid2->set_table_for_first_display
          changing
               it_outtab       = ialv2[]
               it_fieldcatalog = fieldcat2[].
    endmodule.
    *      Module  USER_COMMAND_0200  INPUT
    module user_command_0200 input.
      case sy-ucomm.
        when 'BACK' or 'CANC'.
          perform free_containers.
          if sy-subrc = 0.
            set screen 0.
            leave screen.
          else.
            leave program.
          endif.
        when 'EXIT'.
          perform free_containers.
          leave program.
      endcase.
    endmodule.
    Regards,
    Rich Heilman

  • Dynamic F4 help for workcenter based on plant given in select-option

    Hi all,
    I need to give F4 help on work center based on plant values in the select-options in the selection screen. I am using the FM DYNP_VALUES_READ to get the low and high values in the plant  field of selection screen. The problem is i do not know how to fetch the extension values of s_werks. dynpro fields what i am passing is s_werks-low and s_werks-high. But how will i name the extension field of s_werks. Even i have tries giving only s_werks. But FM is giving invalid dynpro field exception . Please help on this.

    You need to use FM DYNP_VALUES_READ to read values entered on selection screen and then you need to use FM F4IF_INT_TABLE_VALUE_REQUEST.
    FM DYNP_VALUES_READ can read the values of screen fields
    You have to use the function module DYNP_VALUES_READ to read the selection screen data after u enter the field value in Plant . Based on that, then call the function module F4_INT_VALUE_REQUEST. And this function module will
    retrive based on the value enter on the field1.
    F4IF_INT_TABLE_VALUE_REQUEST
    This function module displays a value list that you created in an ABAP program. The value list is passed to the function module as the table parameter VALUE_TAB. If you specify the import parameters DYNPPROG, DYNPNR, and DYNPROFIELD, the user’s selection is returned to the corresponding field on the screen. If you specify the table parameter RETURN_TAB, the selection is returned into the table instead.
    Have a look at below sample code:
    If you have two parameters, you want to display values(f4) in parameter 2 depending on the values entered in parameter 1.
    REPORT Z_SRI_HELP_VALUE_FOR_TABLES .
    tables tcurt.
    DATA DYFIELDS LIKE DYNPREAD OCCURS 1 WITH HEADER LINE.
    PARAMETERS: P_WAERS LIKE TCURT-WAERS, "Currency
    P_LTEXT LIKE TCURT-LTEXT, "Long Text
    P_KTEXT LIKE TCURT-KTEXT. "Short Text
    Example of updating value of another field on the screen
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_WAERS.
    CLEAR: DYFIELDS[], DYFIELDS.
    *select currency
    CALL FUNCTION 'HELP_VALUES_GET'
    EXPORTING
    fieldname = 'WAERS'
    tabname = 'TCURT'
    IMPORTING
    SELECT_VALUE = P_WAERS.
    get long text for the selected currency
    SELECT SINGLE LTEXT FROM TCURT
    INTO DYFIELDS-FIELDVALUE
    WHERE SPRAS = SY-LANGU
    AND WAERS = P_WAERS.
    IF SY-SUBRC 0.
    CLEAR DYFIELDS-FIELDVALUE.
    ENDIF.
    update another field
    DYFIELDS-FIELDNAME = 'P_LTEXT'.
    APPEND DYFIELDS.
    CALL FUNCTION 'DYNP_VALUES_UPDATE'
    EXPORTING
    DYNAME = SY-CPROG
    DYNUMB = SY-DYNNR
    tables
    dynpfields = DYFIELDS .
    Example of reading value of another field
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_KTEXT.
    *read another field
    CLEAR: DYFIELDS[], DYFIELDS.
    DYFIELDS-FIELDNAME = 'P_WAERS'.
    APPEND DYFIELDS.
    CALL FUNCTION 'DYNP_VALUES_READ'
    EXPORTING
    DYNAME = SY-CPROG
    DYNUMB = SY-DYNNR
    TABLES
    DYNPFIELDS = DYFIELDS .
    READ TABLE DYFIELDS INDEX 1.
    get short text and update current field
    SELECT SINGLE KTEXT FROM TCURT
    INTO P_KTEXT
    WHERE SPRAS EQ SY-LANGU
    AND WAERS EQ DYFIELDS-FIELDVALUE.
    Have a look at below sample code:
    REPORT ZTEST_F4 .
    DATA : BEGIN OF ITAB OCCURS 0,
    NAME LIKE KNVK-NAMEV,
    E_MAIL LIKE ADR6-SMTP_ADDR,
    END OF ITAB.
    PARAMETER : P_EMAIL LIKE ADR6-SMTP_ADDR.
    INITIALIZATION.
    ITAB-NAME = 'A'.
    ITAB-E_MAIL = email@removed '.
    APPEND ITAB.
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_EMAIL.
    CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
    EXPORTING
    RETFIELD = 'E_MAIL'
    DYNPPROG = 'ZTEST_F4'
    DYNPNR = '1000'
    DYNPROFIELD = 'P_EMAIL'
    VALUE_ORG = 'S'
    TABLES
    VALUE_TAB = ITAB
    EXCEPTIONS
    PARAMETER_ERROR = 1
    NO_VALUES_FOUND = 2
    OTHERS = 3
    Another Code sample:
    REPORT DEMO_DYNPRO_F4_HELP_MODULE.
    TYPES: BEGIN OF VALUES,
    CARRID TYPE SPFLI-CARRID,
    CONNID TYPE SPFLI-CONNID,
    END OF VALUES.
    DATA: CARRIER(3) TYPE C,
    CONNECTION(4) TYPE C.
    DATA: PROGNAME LIKE SY-REPID,
    DYNNUM LIKE SY-DYNNR,
    DYNPRO_VALUES TYPE TABLE OF DYNPREAD,
    FIELD_VALUE LIKE LINE OF DYNPRO_VALUES,
    VALUES_TAB TYPE TABLE OF VALUES.
    CALL SCREEN 100.
    MODULE INIT OUTPUT.
    PROGNAME = SY-REPID.
    DYNNUM = SY-DYNNR.
    CLEAR: FIELD_VALUE, DYNPRO_VALUES.
    FIELD_VALUE-FIELDNAME = 'CARRIER'.
    APPEND FIELD_VALUE TO DYNPRO_VALUES.
    ENDMODULE.
    MODULE CANCEL INPUT.
    LEAVE PROGRAM.
    ENDMODULE.
    MODULE VALUE_CONNECTION INPUT.
    CALL FUNCTION 'DYNP_VALUES_READ'
    EXPORTING
    DYNAME = PROGNAME
    DYNUMB = DYNNUM
    TRANSLATE_TO_UPPER = 'X'
    TABLES
    DYNPFIELDS = DYNPRO_VALUES.
    READ TABLE DYNPRO_VALUES INDEX 1 INTO FIELD_VALUE.
    SELECT CARRID CONNID
    FROM SPFLI
    INTO CORRESPONDING FIELDS OF TABLE VALUES_TAB
    WHERE CARRID = FIELD_VALUE-FIELDVALUE.
    CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
    EXPORTING
    RETFIELD = 'CONNID'
    DYNPPROG = PROGNAME
    DYNPNR = DYNNUM
    DYNPROFIELD = 'CONNECTION'
    VALUE_ORG = 'S'
    TABLES
    VALUE_TAB = VALUES_TAB.
    ENDMODULE.
    The screen flow logic is as follows:
    PROCESS BEFORE OUTPUT.
    MODULE INIT.
    PROCESS AFTER INPUT.
    MODULE CANCEL AT EXIT-COMMAND.
    PROCESS ON VALUE-REQUEST.
    FIELD CONNECTION MODULE VALUE_CONNECTION.
    For the Flight number field, the POV module VALUE_CONNECTION is called. The
    function module DYNP_VALUE_READ transports the value of the screen field CARRIER into the program. The program then reads the corresponding values from the database table SPFLI into the internal table VALUES_TAB using a SELECT statement, and passes the internal table to F4IF_INT_TABLE_VALUE_REQUEST. This displays the internal table as input help, and places the user’s selection into the screen field CONNECTION.
    I hope it helps.
    Best Regards,
    Vibha
    Please mark all the helpful answers

  • How can I select next page when on shopping website

    When I'm on a shopping website, like BLoomingdales for example, I can't select next page or page 2.  It only stays on the 1st page.  Why is this?

    Hi,
    if you have 3 pages in a smartform do this
    DATA:L_NAME(17)   TYPE C VALUE '%HEADER-FIRSTPAGE'.
    FIELD-SYMBOLS: <FIELD>.
    if plant = '1000'. A page -> B page
      ASSIGN (L_NAME) TO <FIELD>.
      IF SY-SUBRC EQ 0.
        <FIELD> = 'PAGEA'.
      ENDIF.
    ENDIF.
    else               A page -> C page
      ASSIGN (L_NAME) TO <FIELD>.
      IF SY-SUBRC EQ 0.
        <FIELD> = 'PAGEC'.
      ENDIF.
    ENDIF.
    Thanks,
    Nethaji.
    Edited by: Nethaji babu on Apr 30, 2008 8:47 AM

  • Plant Specific Screen Selection Customization

    Hi friends,
    I have a question, I've made a change in the related customization step.
    IMG-> Logistics-General u2013> Material master -> Field Selection -> Define Plant specific field selection and plant specific screen selection
    I deleted one of the status in the field of "maintenance status and "KDEVALBPQSZXCFG" strign became "KDVALBPQSZXCFG"
    (In the line for a specific plant, not all plants)
    The status was "E" and I would like to learn the effect to that change.
    First I expected the system not to allow me to create purchasing view of a material in MM01.
    It allowed indeed. Also it didn't asked me to enter an organizational unit like plant.
    Meanly, I created a material's purchasing view without entering any plant.
    Then I reversed the customization and added "E" to where it belonged before and the string became again  "KDEVALBPQSZXCFG". I tried to create a material again. However the system again didn't asked me any plant.
    How can I bring back the old settings? Should'nt this reverse customization normally bring back it?
    Thanks for your help in advance.
    Best regards,
    Yusuf Gezer

    Hi Sudhi,
    yes I am able to make changes through MM02 for this view, purchasing.
    By the way I think I just found the solution.
    I don't know but somehow during the customization, a check box became active, I realized it while creating a material.
    And it remained as checked even if I made the reverse customization.
    The explanation for the check box: "It is an indicator that causes the data you have entered to be valid for all material master records from this date onwards; the window for entering organizational levels and profiles is redisplayed only on request."
    This lies on the organizational level screen, I saw it when I manually selected that screen.
    It seems there is no problem now.
    Thank you for your interest.
    Best regards,
    Yusuf Gezer

  • Can not select from data dictionary view from a procedure

    Hi,
    I wonder, which privilege is missing here:
    my schema has this roles and privs:
    GRANT CONNECT, RESOURCE TO cb ;
    GRANT CREATE SESSION TO cb ;
    GRANT SELECT_CATALOG_ROLE TO cb ;
    GRANT CREATE SYNONYM TO CB;
    GRANT CREATE VIEW TO CB;
    I create a procedure:
    create or replace procedure dd_test as
    begin
         dbms_output.enable(2000000);
         for r in (select table_name from sys.dba_tab_partitions     where owner = 'CB') loop
                   dbms_output.put_line(r.table_name);
         end loop;
    end;
    sho err
    4/38 PL/SQL: ORA-00942: table or view does not exist
    When I run the core statement form sql prompt, it works !
    so what privilege is missing here ???
    thanks for any hint, Lao De

    Hi,
    thanks for that reply, after doing that I can not select this DD-view from sql-prompt anymore (which I don't wonder ;-). Can you tell me, what idea you had behind that test ?
    I found another instance, where the procedure works and I will compare those privileges, but it's hard to sort out that complex structure of nested roles and sys_privs.
    How ever, I will update here, when I found the missing privilege.
    regards LaoDe

  • Can't select anything in design mode

    I am new on a large Flex project, and when I go into design mode on one of the mxml files, I can't select anything.  The other views work fine.  Is there a lock, or something?   Below is what it looks like (black mark just hides brand info).  Note that there is a red line near the bottom.  It is actually selectable, but it doesn't do anything.  If I go to Source mode and select a chunk of code, then back to design mode, it does show it as selected.
    This in Flex Builder 3, thanks.

    Have you tried using the outline view for selection?
    Jason San Jose
    Software Engineer, Flash Builder

  • Can not "select" partitioning snapshot ?

    I can create partitioning snapshot ( Oracle 8 ) , but I can
    issue SELECT statement with partition-extended object name
    Ex : Selet * from snapshot_name patition ( par_name )
    How to SELECT data from snapshot with partition-extended object
    name ?
    null

    I can create partitioning snapshot ( Oracle 8 ) , but I can
    issue SELECT statement with partition-extended object name
    Ex : Selet * from snapshot_name patition ( par_name )
    How to SELECT data from snapshot with partition-extended object
    name ?
    null

  • Can not select TV speakers when connected via HDMI

    I have a MBP fully updated connected to a Sony TV vis HDMI/miniport.  Up until today this configuration was working fine.  Suddenly, I can no longer select the HDMI speakers in my audio preferences.  They are recognized and appear on the list but when I select them it has no effect.  Before today, when the TV was connected the HDMI output would be automatically selected and I could not access the volume control from the menu bar, which is the way I prefer it. 
    I have restarted with no success in changing this behaviour.  If I open/close the lid, the sound goes to the proper settings for about 2s but then the HDMI speakers are de-selected and the built-in speakers are highlighted.  I can manually select the TV speakers but the setting has no effect.
    However, I *am* getting audio output through the TV but can not control volume from the mac or any app.  I slide the volume slider on the menu bar and the audio output does not change.  The sound is also playing from the laptop speakers which is highly annoying.

    and now there is no audio through the TV at all.  TV works fine with other inputs such as PS3.  Any help?

  • Can not select 'Show HD' in Finder Preferences

    Just performed Data Migration on a new iMac Intel late 2011 from a 2 year old iMac Intel.  For some reason, the Macintosh HD does not display on the desktop.  If I go to Finder Preferences I can not select Hard Disks.  The box is not selected, but If I try to click it, it will not stick.  How do I fix that.  Not much on the internet concering this peculiarity.

    OK, try a couple of things. First is to do some resets, the first I'd recommend doing is restarting the computer in  Safe Mode, this will clear some caches. It's possible one is corrupt. Next is to reset the SMC and PRAM, each of these should be done 2x to ensure they work. Finally if that doesn't do it open Disk Utility (Applications - Utilities - Disk Utility) and Repair Disk Permissions 2x.
    SMC RESET
    Shut down the computer.
    Unplug the computer's power cord and all peripherals.
    Press and hold the power button for 5 seconds.
    Release the power button.
    Attach the computers power cable.
    Press the power button to turn on the computer.
    PRAM RESET
    Shut down the computer.
    Locate the following keys on the keyboard: Command, Option, P, and R. You will need to hold these keys down simultaneously in step 4.
    Turn on the computer.
    Press and hold the Command-Option-P-R keys. You must press this key combination before the gray screen appears.
    Hold the keys down until the computer restarts and you hear the startup sound for the second time.
    Release the keys.

  • Can not select an address from Contacts in Maverick

    I'm able to access my address book contacts from Mail. 
    But when Contacts window is open,  I can not select a contact (For, CC, Bcc Fields are in grey).
    Is there anyone with suggestions?
    Many thanks!

    Hello
    I am not selecting a group. I am just trying to select a contact, any contact.
    But when I click on contacts icon ...
    and the address book opens, nothing happens when clicking on a specific contact.
    Besides, the fields For (= Para), Cc and Bcc, are not active...
    Many thanks

  • Can not select from SAPTOOLS.DB6PMCF

    We use third-party tool to monitor our SAP systems. We receive an error
    Can not select from SAPTOOLS.DB6PMCF
    when we monitor DB2 database.
    Function DB6PMCF is registered in SAPSID schema. Can I register it also in SAPTOOLS schema? What is a correct procedure for this?

    Hi Milan,
    I think you have to issue the following command for the affected user.
    db2 "grant execute on function saptools.db6pmcf to <user>"
    regards, Javier Rocha

  • Can not select external input for sound

    can not select external input for sound

    Hey there RoosterMonkey,
    It sounds like you have Soundtrack Pro installed but you cannot select your external audio device as an input. I recommend the troubleshooting steps from the article named:
    Soundtrack Pro 3: Troubleshooting Basics
    http://support.apple.com/kb/ht3659
    Update to the latest software versions
    From the Apple () menu, choose Software Update and make sure that you have the most recent updates for your versions of Soundtrack Pro 3, QuickTime, Compressor, Pro Application Support, and other important system files. Installing the latest updates ensures that your software has the latest improvements and enhancements.
    Note: Be sure the application is in the Applications folder and is named Soundtrack Pro before running Software Update.
    Check compatibility and driver versions for third-party devices
    If you're using a third-party sound card, MIDI interface, storage system, control surface, or plug-in, check the support area on the manufacturer's website to be sure that you're using the latest version of the relevant driver or other software for your product. For information on troubleshooting possible issues with Audio Unit plug-ins, go to Soundtrack Pro 3: Troubleshooting Audio Unit plug-in issues.
    Try a different Multitrack Project or Audio File Project
    Sometimes project files can become damaged, causing unexpected behavior in Soundtrack Pro. To create a fresh project, choose File, then New and select Multitrack Project or Audio File. Test to see if the issue is resolved in the new project.
    Delete the User Preferences
    You can resolve many issues by restoring Soundtrack Pro to its original settings. This will not impact your project files. To reset your Soundtrack Pro user preference settings to their original state:
    Quit Soundtrack Pro if it is open.
    In the Finder, choose Go > Go to Folder from the menu bar.
    Type ~/Library/Preferences  in the "Go to the folder" field.
    Remove the "com.apple.soundtrackpro.plist" file from the Preferences folder.
    In the Finder, choose Go > Go to Folder from the menu.
    Type ~/Library/Application Support/Soundtrack Pro  in the "Go to the folder" field.
    Remove the "EffectsCache.plist" file from the Soundtrack Pro folder.
    In the Finder, choose Go > Go to Folder from the menu.
    Type ~/Library/Application Support/Soundtrack Pro/Layouts  in the "Go to folder" field.
    Remove the "Soundtrack Pro.saved.moduleLayout" file from the Layouts folder.
    In the Finder, choose Go > Go to Folder from the menu.
    Type ~/Library/Caches in the "Go to folder" field.
    Remove the "com.apple.audiounits.cache" from the Caches folder.
    Remove receipts and reinstall Soundtrack Pro 3 and Compressor
    Another approach you might consider is reinstalling Soundtrack Pro and Compressor. To do this effectively, you need to remove the applications and their receipts, then install Soundtrack Pro and use Software Update to install additional updates. Compressor gets installed automatically when you install Soundtrack Pro. You don't have to remove everything that was installed with Soundtrack Pro, so follow the steps below to completely reinstall a fresh copy of Soundtrack Pro. Note: Make sure that you have your installation discs handy before beginning.
    In Mac OS X v10.6 Snow Leopard or OS X Lion
    Open the Terminal application and enter the following commands one at a time and an administrator password when prompted. Note: The commands are case sensitive.
    sudo pkgutil --forget com.apple.pkg.Compressor
    sudo pkgutil --forget com.apple.pkg.Qmaster
    sudo pkgutil --forget com.apple.pkg.VideoOutSupport
    sudo pkgutil --forget com.apple.pkg.PSTSharedA
    sudo pkgutil --forget com.apple.pkg.AppleHDVCodec
    sudo pkgutil --forget com.apple.pkg.AppleIntermediateCodec
    sudo pkgutil --forget com.apple.pkg.DSPPublishing
    sudo pkgutil --forget com.apple.pkg.SoundtrackPro
    sudo pkgutil --forget com.apple.pkg.Uncompressed422
    Then, reinstall Soundtrack Pro and Compressor using the following steps:
    Open the Applications folder. Drag the Soundtrack Pro and Compressor applications to the Trash.
    Insert your Logic Studio or Final Cut Studio installation disc and install Soundtrack Pro.
    When finished installing, choose the Apple () menu, then Software Update to update your software to the latest version.
    Open Soundtrack Pro to verify that the issue has been resolved.
    Thank you for using Apple Support Communities.
    Cheers,
    Sterling

  • ADF 11g can not select and copy data from cell of readonly table in IE

    hi,
    In ADF 11g, when render view object as readonly table with Single RowsSelection, using IE browser can not select and copy data from the cell, but it work in firefox.
    is it a bug?
    Edited by: kent2066 on 2009-5-18 上午8:46

    Hi Timo,
    Sorry forgot to mention versions.
    We are using 11.1.1.7 and IE 9.
    I tried in Google but could not get the solution.
    Kindly let me know solution for this.
    PavanKumar

  • Can I Select from table skipping extents linked with lost datafiles?

    Hi~,
    I need your help to recover my database.
    I'm using oracle 9.2.0.8 at Fedora 3 with no-archive mode.
    and I don't have any backup.
    Last night, I experenced hard disk failure.
    I tried OS-level recovery, but I lost some datafiles of tablespace.
    anyway, I wanted to recover my database without data of lost datafiles.
    so, I issued "alter database datafile offline drop" and
    start oracle instance.
    But, datafiles were not removed from dba_data_files view and
    extents linked with lost datafiles were not removed from dba_extents view!
    Selecting query of some table containing extents linked with lost data files,
    I got "ORA-00376: file xxx cannot be read at this time" message.
    So, my question is that..
    HOW CAN I SELECT FROM THAT TABLE WITHOUT SCANNING EXTENTS LINKED WITH LOST DATA FILES?
    Thanks.

    Hi,
    Without being in archivelog and without backup, one can't do any sort of recovery. That's why backups and archivelog are so so important.
    The offline data file command never does actually drop the datafile. It merely indicates to the control file that now the said tablespace will also be dropped. This won't update any view that the files are not supposed to be used or shown to you anymore.
    This is what documentation says about the recovery of the database in the NoARch mode,
    http://download.oracle.com/docs/cd/B19306_01/backup.102/b14191/osrecov.htm#i1007937
    You do need a backup in order to get those tables being read. Oracle doesn't have any feature which can offline/skip the missing extents for you and let you read the data without them.
    HTH
    Aman....