Hi All,
i had created an Custom Infotype.
In that infotype i had created Tabstrip control with 2tabs.
Each Tab contain 4 fields.
When creating( F5) a record in transaction PA30, it allowing me create a record and the record is available in Data base table.
1. My doubt is, when Display the Record through F7 and Change mode (F6), Still the fields are in editable mode. But not in Display Mode ( Editable Mode ).
How to Disable the Fields for this Tab Strip Control. I have not used any Group Field for this. Can we need to Main tain anything.
But SAVE option is automatically disabled.Iam not able to SAVE when i press F7 but in Editable is the My Problem.
2. And one more query is, when press F5 or F6 or F7 it is show the following message at End screen,i.e.
Protected tab titles are not supported (tab MENU_TABSTRIP title PUSH1) . But MENU_TABSTRIP is My Tab Strip control text Name and PUSH1 is my Tab1 , Function code.
How to remove this message.
Points will be rewarded.
Thanks,
N.L.

Hi,
Try this ....In the Table Control, double click on a field. In the attributes make that field as output only...
Hope it helps,
Swathi

Similar Messages

  • Table update problem in tabstrip control

    Hi experts.
    i have one tabstrip control having 4 tabs.
    in those tabs i am updating one table say ztable(database table).
    my problem is this is happening in pai of every tab.
    but what ever i am updateing table those changes will reflect in other tabs.
    where i have to write code like pbo or what i should do.
    what ever i am updateing in tab1 i have to see in tab2.what ever i have update i should see in tab3.
    but it is not showing the updates when we will go for other tabs.
    Thanks

    Hi,
    Please check the following things :
    1 . The Fucntion code type for each tab is blank
    2 . Same subscreen area is assigned to each tab
    3 . Corresponding subscreen is dynamically incorporated into the subscreen area CALL SUBSCREEN in the flow logic
    If you are not doing this, then you are scolling in SAP GUI, not in your program. In this case the values entered in TAB1 won't get reflected in TAB2.
    If this is the case in your program, fix the above three points. then it will work.

  • Problem in Tabstrip Control in Custom Infotype Creation

    Hi All,
    Can any body tell me how to process with Tabstrip Control in an Custom Infotype.
    Iam creating Customizing Infotype With Tabstip Control.The Tabstrip Control have 2tabs.Each tab have Custom some fields.
    But iam not able activating the sample Tabstrip control.
    Can u tell me how to approach to create this in Modulepool programming for my Custom Infotype.
    Points wil be rewarded.
    Thanks,
    N.L.Narayana

    Hello Swapna,
    Thanks for your reply.
    This is my code for tabstrip control.
    AT SELECTION-SCREEN.
    CASE SSCRFIELDS-UCOMM.
       WHEN 'BOOK'.
         tabb1-prog = 'ZAXOMM005_V1'.
         tabb1-dynnr = 1.
         tabb1-activetab = 'TABS1'.
         option = '1'.
       WHEN 'SUMM'.
         tabb1-prog = 'ZAXOMM005_V1'.
         tabb1-dynnr = 2.
         tabb1-activetab = 'TABS2'.
         option = '2'.
       WHEN 'POST'.
         tabb1-prog = 'ZAXOMM005_V1'.
         tabb1-dynnr = 3.
         tabb1-activetab = 'TABS3'.
         option ='3'.
    *CH01 start
       WHEN 'RSET'.
         tabb1-prog = 'ZAXOMM005_V1'.
         tabb1-dynnr = 4.
         tabb1-activetab = 'TABS4'.
         option = '4'.
    ENDCASE.
    case option.
      when '1'.
    IF  SSCRFIELDS-UCOMM = 'ONLI'.
       if p1_werks is initial or p1_lgort is initial or
          p1_bstar is initial or p1_gjahr is initial.
         message e000(vz) with text-001.
       endif.
    ENDIF.
      when '2'.
    IF  SSCRFIELDS-UCOMM = 'ONLI'.
       if p2_gjahr is initial.
         message e000(vz) with text-005.
       endif.
    ENDIF.
      when '3'.
    IF  SSCRFIELDS-UCOMM = 'ONLI'.
       if p3_gjahr is initial.
         message e000(vz) with text-005.
       endif.
        ENDIF.
    *CH01 start
      when '4'.
    IF  SSCRFIELDS-UCOMM = 'ONLI'.
      if s4_werks is initial or p4_gjahr is initial.
         message e000(vz) with text-001.
      endif.
      if p4_book is initial and
         p4_summ is initial.
         message e000(vz) with text-022.
      endif.
       ENDIF.
    endcase.
    I can give you some more information.
    If I execute from program it is working fine, if I execute from T.code it is not working properly.
    Regards.
    Krishna.

  • Tabstrip Control Problem

    I created a form with a a two-tab tabstrip (using the wizard).  On the first tab is an ALV grid, on the second, a text field.  When I run the program and the first grid shows up with the ALV grid just fine.  When I click the second tab, however, the program just terminates.  I'm a newbie so it's probably something obvious.  Thanks in advance!

    hi ,
    look at this...
    http://help.sap.com/saphelp_nw04/helpdata/en/04/10f2469e0811d1b4700000e8a52bed/frameset.htm
    Tabstrip control
    check this test code...
    TABLES : VBAK ,VBAP.
    CONTROLS : TAB_STRIP TYPE TABSTRIP.
    CONTROLS : TAB_CNTRL TYPE TABLEVIEW USING SCREEN 0002.
    DATA : OK_CODE_0101(20).
    DATA : D_REPID TYPE SY-REPID,
    D_SUBSCR TYPE SY-DYNNR.
    DATA : D_VBELN TYPE VBAK-VBELN.
    TYPES : BEGIN OF D_STRUCT,
    VBELN TYPE VBELN_VA,
    POSNR TYPE POSNR_VA,
    MATNR TYPE MATNR,
    FMENG TYPE FMENG,
    NETWR TYPE NETWR_AP,
    END OF D_STRUCT.
    DATA : ITAB TYPE STANDARD TABLE OF D_STRUCT WITH HEADER LINE.
    DATA : D_WA TYPE D_STRUCT.
    *& Module GET_SCR OUTPUT
    text
    module GET_SCR output.
    IF OK_CODE_0101 IS INITIAL.
    D_SUBSCR = '0001'.
    ENDIF.
    D_REPID = SY-REPID.
    endmodule. " GET_SCR OUTPUT
    *& Module EXIT_MODULE INPUT
    text
    module EXIT_MODULE input.
    SET SCREEN 0.
    LEAVE SCREEN.
    endmodule. " EXIT_MODULE INPUT
    *& Module USER_COMMAND_0101 INPUT
    text
    module USER_COMMAND_0101 input.
    case ok_code_0101.
    when 'TAB1'.
    D_SUBSCR = '0001'.
    TAB_STRIP-ACTIVETAB = 'TAB1'.
    WHEN 'TAB2'.
    D_SUBSCR = '0002'.
    TAB_STRIP-ACTIVETAB = 'TAB2'.
    WHEN 'GET1'.
    D_SUBSCR = '0002'.
    TAB_STRIP-ACTIVETAB = 'TAB2'.
    ENDCASE.
    regards,
    venkat.

  • Tabstrip control  Tab line navigation button display issue

    I have a tabstrip that has more tabs than can be displayed at the top of the tabstrip control.  When this happens a navigation button appears on the far right of the tab line( the line that contains all the tabs).  This has been working fine for several years.  Recently I needed to increase the width of the tabstrip control so that it was 160 character wide.  Now when the tabstrip displays, the tab line stops displaying at around 130 characters so the navigation button no longer shows.  As it turns out, the button is still there and functions as normal, except that it cannot be seen even though there are still too many tabs to all be displayed. 
    This appears to me to be a bug in the tabstrip control, but before I start complaining to SAP I thought I would ask here to see if anyone else might know of a solution to this problem. 
    Thanks for looking.

    Hi,
    cresate a managed bean in viewScope within the parent page and pass it as an argument to the child task flow. The managed bean contains/exposes a method to hide the menu items you don't want to show (or just disable them). The child task flow then can call the managed bean (from its input parameter reference) and invoke the method (e.g. in a method call activity as the default activity of the task flow).
    See this blog entry for more details: http://one-size-doesnt-fit-all.blogspot.de/2010/09/master-child-btf-chaperone-contextual.html
    Frank

  • Module Pool (tabstrip control Error :  )

    I am trying to activate tabstrip control in module pool but error is coming like no sub screen is assigned to tabstrip pushbutton
    tab12.
    my main screen is : 0221
    flow logic for 0221 is below :
    PROCESS BEFORE OUTPUT.
    CALL SUBSCREEN SUB1 INCLUDING SY-REPID '0321'.
    CALL SUBSCREEN SUB2 INCLUDING SY-REPID '0322'.
    PROCESS AFTER INPUT.
    CALL SUBSCREEN SUB1.
    CALL SUBSCREEN SUB2.
    MODULE USER_COMMAND_0221.
    and 0321 and 0322 is subscreen and i also gave ref field sub1 and sub2 .
    can you plz help me to solve the problem ?

    Hi,
    yes i created sub screen. i am going to explain what i have done .
    step : i created screen 200 (i choose subscreen)and inside 200 i put  tabstripcontrol then in tab1 i gave ref field sub1 and tab2 i gave ref field sub2 and fatch code ic1 and ic2.
    and then i created screen 221 and 222.
    inside 200 flow logic i wrote below code but still its giving me same error.
    PROCESS BEFORE OUTPUT.
    CALL SUBSCREEN SUB1 INCLUDING SY-REPID '0221'.
    CALL SUBSCREEN SUB2 INCLUDING SY-REPID '0222'.
    PROCESS AFTER INPUT.
    CALL SUBSCREEN SUB1.
    CALL SUBSCREEN SUB2.
    MODULE USER_COMMAND_0221.
    i dont know is it required to make any normal screen .
    please try to give me ans as soon as possible.

  • Screen error in tabstrip control

    hi all,
    I'm practicing a program for Tabstrip control.
    it will be like this
    tab1           tab2
    number1    result
    number2
    number1 number2 result are of integer data types.
    now the problem is
    the program is giving result when I declare the above variables as char...that to with some limit.
    but if the varilable are of type int program is givng an error called screen error.
    why this is happening ?
    whats the solution for it?
    points assured,
    Usha.

    HI,
    try like this...
    1.goto that perticular Screen Element List, there you will find a tab General Attributes.
    2.In that change the Format Column for that perticular field from CHAR to INT1 ( by default it will take as CHAR ).
    now you will not get any error.
    Regards,
    Sathish Reddy.

  • Tabstrip control issue, screen freezes

    I have a Screen with a tabstrip control with 4 tabs.  It will let me select tab 1, tab 2, tab 3, and tab 4, but when tab 4 is selected, and i click another tab, the screen freezes, and will not allow me to get out, what is the problem?

    Can you send the code ,may after the tab 4 is selected ,you are not activating the tab or no screen is attached.

  • Status icons on tabstrip controls

    Hello
    I have a problem displaying the status icon on a tabstrip control.
    I've created an infotype. On the tabstrip control, I've added texteditors and status icons.The status icon is there as an indication to state whether there is information populated in the texteditor.
    The texteditors all have information populated in them. Whenever I run the infotype on PA30, the status icon does not appear. It only appears when I click on the texteditor button which is not what i want it to do.
    On PA30,I would like the ICON to appear when there is information in the texteditor and not when I click on the texteditor button.
    Please advice me on how to fix this problem.
    Thanks
    Adhil Ramruthan

    REPORT  ZICON_CONTROL.
    tables: icon.
    controls: tc type tableview using screen 100.
    data: begin of it_data occurs 0,
           icon(4),
           value(02),
          end of it_data.
    "Based on condion you populate the ICON data here
    "if the case is editable and then you have to do the same in PBO
    it_data-icon = '@0A@'."ICON_RED_LIGHT.
    it_data-value = '00'.
    append it_data.
    it_data-icon = '@08@'. "ICON_GREEN_LIGHT.
    it_data-value = '01'.
    append it_data.
    call screen 100.
    *&      Module  transfer_data  OUTPUT
    *       text
    module transfer_data output.
    read table it_data index tc-current_line.
    endmodule.                 " transfer_data  OUTPUT
    Flow logic.
    PROCESS BEFORE OUTPUT.
    MODULE STATUS_0100.
    loop at it_data with control tc.
      module transfer_data.
    endloop.
    PROCESS AFTER INPUT.
    loop.
    endloop.
    MODULE USER_COMMAND_0100.

  • Tabstrip Controls Einfügen

    Hallo,
    ich habe ein kleines Problem mit dem Tabstrip Control im SUD Editor.
    1. Welches ActiveX Control ist am besten geeignet?
    2. Wenn ich anderes Controls einen Tabtrip zuordnen, ich habe das Problem das der Tabstrip immer im Vordergrund ist und eine einstellung wie zOrder habe ich nicht gefunden. Ich schätze das es irgendwie mit der Layersteuerung funktioniert, aber leider hatt bisher alles nicht funktioniert.
    Über eine kleine Hilfestellung oder Gedankenanregung würde ich mich freuen.
    Viele Grüße
    Axel Manz

    Hallo Herr Manz,
    Sie haben Recht, so etwas programmiert man am Besten über die Layers des Dialogs. Ich lade dazu mal ein kleines Beispiel hoch, es simuliert eine Art TabControl - vielleicht können Sie es ja direkt anwenden.
    Allgemein kann der Z-Index der Bedien- und Anzeigeelemente über die Tabulatorreihenfolge festgelegt werden (Kontextmenü...) Das wirkt sich aber erst bei laufendem Dialog aus, und nicht in der Entwicklungsumgebung.
    Ingo Schumacher
    Applications Engineering
    National Instruments
    Attachments:
    TabControl.sud ‏13 KB

  • How can i hide a tabstrip control

    On my screen there are a pushbutton and a tabsrtip control which contain two tabs.
    initial,the tabstrip is visible,and the button with icon_collapse icon.
    then,i click the button ,and the tabstrip must be invisible,and the button's icon will change to icon_expand.
    if i use screen-name conditions to set the tab invisible,but the tabstrip has a shadow on the screen.the color of the space obtained by the tabstrip is different with other space's color.
    How can i set the color same with other if i want to hide the tabstrip.
    ths very much.

    see the example of custom tabstrip control for 0591 infotype
    MODULE ztab_strip_active_tab_set OUTPUT.
       IF  psyst-dsubt EQ 'BNPF'.
         g_ztab_strip-pressed_tab = c_ztab_strip-tab2.
         LOOP AT SCREEN.
           IF screen-group4 = '060'.
             screen-active = 0.
             MODIFY SCREEN.
           ENDIF.
         ENDLOOP.
       ELSEIF  psyst-dsubt EQ 'BNES'.
         g_ztab_strip-pressed_tab = c_ztab_strip-tab1.
         LOOP AT SCREEN.
           IF screen-group4 = '050'.
             screen-active = 0.
             MODIFY SCREEN.
           ENDIF.
         ENDLOOP.
       ENDIF.
       IF   psyst-dsubt NE 'BNPF' AND psyst-dsubt NE 'BNES'.
          LOOP AT SCREEN.
           IF screen-group4 = '050'.
             screen-active = 0.
             MODIFY SCREEN.
           ENDIF.
         ENDLOOP.
          LOOP AT SCREEN.
           IF screen-group4 = '060'.
             screen-active = 0.
             MODIFY SCREEN.
           ENDIF.
         ENDLOOP.
         g_ztab_strip-pressed_tab = ' '.
       ENDIF.
       ztab_strip-activetab = g_ztab_strip-pressed_tab.
       CASE g_ztab_strip-pressed_tab.
         WHEN c_ztab_strip-tab1.
           g_ztab_strip-subscreen = '0201'.
         WHEN c_ztab_strip-tab2.
           g_ztab_strip-subscreen = '0203'.
         WHEN OTHERS.
           g_ztab_strip-subscreen = '0202'.
       ENDCASE.
    ENDMODULE.                    "ZTAB_STRIP_ACTIVE_TAB_SET OUTPUT
    check this for hiding one tabstrip in one subtype and another in next subtype

  • How to insert tabstrip control in module pool screen painter

    Hi all!
    plz tell e how to use tabstrip control in module pool screen painter.Also plz give me an example program using tabstrip control.

    To insert tabstrip just open layout of screen and press on the tabstrip button there .
    Use this souce code further to activate it .
    CONTROLS tabstrip TYPE TABSTRIP.
    DATA: okcode TYPE sy-ucomm,
    dynnr TYPE sy-dynnr,
    flag type flag,
    active like tabstrip-activetab .
    call SCREEN 100.
    *& Module USER_COMMAND_0100 INPUT
    text
    MODULE USER_COMMAND_0100 INPUT.
    data: lv_okcode type syucomm.
    lv_okcode = okcode.
    clear okcode.
    case lv_okcode.
    WHEN 'TAB1'.
    dynnr = '0110'.
    WHEN 'TAB2'.
    dynnr = '0120'.
    WHEN 'TAB3'.
    dynnr = '0130'.
    WHEN 'TAB4'.
    dynnr = '0140'.
    WHEN 'TAB5'.
    "check authorization, if authorization fails
    flag = 'X'. "set the global flag
    active = 'TAB1'. "store active tab in global variable
    dynnr = '0110'. "set the screen number
    WHEN 'BACK' or 'EXIT'.
    leave program.
    ENDCASE.
    IF lv_okcode(3) = 'TAB'.
    tabstrip-activetab = lv_okcode.
    ENDIF.
    ENDMODULE. " USER_COMMAND_0100 INPUT
    *& Module STATUS_0100 OUTPUT
    text
    MODULE STATUS_0100 OUTPUT.
    SET PF-STATUS 'MAIN'.
    SET TITLEBAR 'xxx'.
    IF tabstrip-activetab IS INITIAL OR
    dynnr IS INITIAL.
    tabstrip-activetab = 'TAB1'.
    dynnr = '0110'.
    ENDIF.
    "set the activetab explicilty here
    if flag eq 'X'. "from authorization failure
    tabstrip-activetab = active. "'TAB1'
    clear flag.
    endif.
    ENDMODULE. " STATUS_0100 OUTPUT

  • How to hide tabstrip Control at runtime?

    hi to all.
    i used a tabstrip control in my screen.
    i want to make my tabstrip visible or invisible based on t-code
    for my screen.
    it will be total based on t-code.
    if i will enter t-code zins11 it will show me tabstrip for screen 100.
    if i will enter t-code zins12 it will hide me tabstrip for screen 100.
    Reply me.
    thanks.

    If you don't mind seeing the blank grey Tab Strip control box and simply hiding the tabs, this code will help.
      LOOP AT SCREEN.
        IF screen-name CP 'TS_TEST1_TAB*'.
          screen-active = 0.
          modify screen.
        ENDIF.
      ENDLOOP.
    where my Tab Strip name was 'TS_TEST1

  • Problem with custom control and focus

    I've a problem with the focus in a custom control that contains a TextField and some custom nodes.
    If i create a form with some of these custom controls i'm not able to navigate through these fields by using the TAB key.
    I've implemented a KeyEvent listener on the custom control and was able to grab the focus and forward it to the embedded TextField by calling requestFocus() on the TextField but the problem is that the TextField won't get rid of the focus anymore. Means if i press TAB the first embedded TextField will get the focus, after pressing TAB again the embedded TextField in the next custom control will get the focus AND the former focused TextField still got the focus!?
    So i'm not able to remove the focus from an embeded TextField.
    Any idea how to do this ?

    Here you go, it contains the control, skin and behavior of the custom control, the css file and a test file that shows the problem...
    control:
    import javafx.scene.control.Control;
    import javafx.scene.control.TextField;
    public class TestInput extends Control {
        private static final String DEFAULT_STYLE_CLASS = "test-input";
        private TextField           textField;
        private int                 id;
        public TestInput(final int ID) {
            super();
            id = ID;
            textField = new TextField();
            init();
        private void init() {
            getStyleClass().add(DEFAULT_STYLE_CLASS);
        public TextField getTextField() {
            return textField;
        @Override protected String getUserAgentStylesheet() {
                return getClass().getResource("testinput.css").toExternalForm();
        @Override public String toString() {
            return "TestInput" + id + ": " + super.toString();
    }skin:
    import com.sun.javafx.scene.control.skin.SkinBase;
    import javafx.beans.value.ChangeListener;
    import javafx.beans.value.ObservableValue;
    import javafx.event.EventHandler;
    import javafx.scene.control.TextField;
    import javafx.scene.input.KeyCode;
    import javafx.scene.input.KeyEvent;
    public class TestInputSkin extends SkinBase<TestInput, TestInputBehavior> {
        private TestInput control;
        private TextField textField;
        private boolean   initialized;
        public TestInputSkin(final TestInput CONTROL) {
            super(CONTROL, new TestInputBehavior(CONTROL));
            control     = CONTROL;
            textField   = control.getTextField();
            initialized = false;
            init();
        private void init() {
            initialized = true;
            paint();
        public final void paint() {
            if (!initialized) {
                init();
            getChildren().clear();
            getChildren().addAll(textField);
        @Override public final TestInput getSkinnable() {
            return control;
        @Override public final void dispose() {
            control = null;
    }behavior:
    import com.sun.javafx.scene.control.behavior.BehaviorBase;
    import javafx.beans.value.ChangeListener;
    import javafx.beans.value.ObservableValue;
    import javafx.event.EventHandler;
    import javafx.scene.input.KeyCode;
    import javafx.scene.input.KeyEvent;
    public class TestInputBehavior extends BehaviorBase<TestInput> {
        private TestInput control;
        public TestInputBehavior(final TestInput CONTROL) {
            super(CONTROL);
            control = CONTROL;
            control.getTextField().addEventFilter(KeyEvent.KEY_PRESSED, new EventHandler<KeyEvent>() {
                @Override public void handle(final KeyEvent EVENT) {
                    if (KeyEvent.KEY_PRESSED.equals(EVENT.getEventType())) {
                        keyPressed(EVENT);
            control.focusedProperty().addListener(new ChangeListener<Boolean>() {
                @Override public void changed(ObservableValue<? extends Boolean> ov, Boolean wasFocused, Boolean isFocused) {
                    if (isFocused) { isFocused(); } else { lostFocus(); }
        public void isFocused() {
            System.out.println(control.toString() + " got focus");
            control.getTextField().requestFocus();
        public void lostFocus() {
            System.out.println(control.toString() + " lost focus");
        public void keyPressed(KeyEvent EVENT) {
            if (KeyCode.TAB.equals(EVENT.getCode())) {
                control.getScene().getFocusOwner().requestFocus();
    }the css file:
    .test-input {
        -fx-skin: "TestInputSkin";
    }and finally the test app:
    import javafx.application.Application;
    import javafx.scene.Scene;
    import javafx.scene.control.TextField;
    import javafx.scene.layout.GridPane;
    import javafx.stage.Stage;
    public class Test extends Application {
        TestInput input1;
        TestInput input2;
        TestInput input3;
        TextField input4;
        TextField input5;
        TextField input6;
        Scene     scene;
        @Override public void start(final Stage STAGE) {
            setupStage(STAGE, setupScene());
        private Scene setupScene() {
            input1 = new TestInput(1);
            input2 = new TestInput(2);
            input3 = new TestInput(3);
            input4 = new TextField();
            input5 = new TextField();
            input6 = new TextField();
            GridPane pane = new GridPane();
            pane.add(input1, 1, 1);
            pane.add(input2, 1, 2);
            pane.add(input3, 1, 3);
            pane.add(input4, 2, 1);
            pane.add(input5, 2, 2);
            pane.add(input6, 2, 3);
            scene = new Scene(pane);
            return scene;
        private void setupStage(final Stage STAGE, final Scene SCENE) {
            STAGE.setTitle("Test");
            STAGE.setScene(SCENE);
            STAGE.show();
        public static void main(String[] args) {
            launch(args);
    The test app shows three custom controls on the left column and three standard textfields on the right column. If you press TAB you will see what i mean...

  • Problems with remote control and user accounts - error 1759?

    We're running:
    -XP Pro SP2 clients with Zen SP1 IR3a agent, 4.91 SP2 Netware client.
    -We are NOT running Middle Tier.
    -Novell servers are running Netware 6.5 SP7, E-directory 8.7.3.10b or 8.8.
    -Zen server is also SP1 IR3a.
    We have no problem using remote control on workstation objects. We are having intermittent issues with remote controlling user objects. When the issue occurs, we receive the following error, "Error 1759: The selected user is not logged in on any workstations" even though the user is in fact logged in. After some more research, it appears that the "networkAddress" attribute of the user object is blank so we feel that this is the root cause. My question is what would cause the networkAddress attribute to randomly not update? For instance we had a user (verified his login) who we could not remote via the user object (workstation object worked). We checked his networkAddress attribute and found that it was empty. User rebooted and logged in again and his networkAddress attribute populated, and then we could remote control him via the user object. Now this isn't always the case after a reboot. There doesn't appear to be any pattern to when the networkAddress attribute does or does not update. In fact, this particular user has a laptop so he boots it up fresh every morning yet he was not showing a network address when he logged in initially today.
    We've followed the troubleshooting steps in Novell Documentation without any success. Is there anything else that we might be missing, especially with respect to getting the networkAddress attribute to update? We ran a DSreport on that attribute and found about 500 out of a total of 1500 users had no networkAddress. Some of those are sure to be legitimate but that number is much too high for the number of people that should be in the office.
    I've read some older threads on the subject but none of them really provide a firm solution. Also most of the older threads reference Middle Tier which we are not using.
    Thanks in advance.

    > 4.91 SP2 Netware client.
    You could try this TID:
    "A user will no longer have an entry in their "Network Address" attribute
    even though they are logged into the eDirectory Tree."
    http://www.novell.com/support/viewCo...1262&sliceId=1
    "Resolution"
    "This was fixed in the 4.91 SP3 client. NWFS.SYS was modified so that it
    will check the monitor connection on a reconnect and if it is not connected
    close the connection and try and get a new monitor connection to the tree.
    Prior to the 4.91 SP3 client, the solution is to have the user login again
    so that it issues the NDS Finish Login request again that will populate
    Network Address again."
    Regards
    Rolf Lidvall
    Swedish Radio (Ltd)