Problem with Seeburger BIC

Hi Guru.
I've a question for you!!
I'm using the Seeburger BIC Mapping Designer but I'va a big problem: I' can't create the deploy file.
I'm try to follow all the documentation that i find in internet but doesn't work...
After the generation of the XML 2 EDI mapping I want to create the deploy file.
After the selection of this function the system shows the following message:
"You can't create a deploy file for this project! There is no SDA/SCA numbers for this project!"
Have you some solution or workaround?
Thanks
Regards Manuel Chiarelli

Hello Manuel
I assume the Seeburger MD is installed on a client system? If yes, you need to start the Mapping Designer in ProjectAdmin mode.
Below is an excerpt from the SAP_BICMD_config_en.pdf. See the section "Start Mapping Designer as ProjectAdmin"                                                                               
Start Mapping Designer as ProjectAdmin                                    
In order to assign projects to SCAs, you need to modify the bic_mapping_designer.ini. This file is located under <BIC MD Installation path>/Bin/bic_mapping_designer_ini. Open the file with your  
favorite text editor and add to following line below the last CmdLineArg <number> line
CmdLnArgX=-ProjectAdmin                                                   
Please note the CmdLnArgX prefix must have an ascending numbering where X is representing the number. Save the file and exit. After that restart the MappingDesigner.           
Regards
Mark

Similar Messages

  • SAP GTS------- SAPPI with Seeburger BIC----- ATLAS using with SAP PI

    Hi All,
    I have scenario this SAP GTS----->SAPPI with Seeburger BIC--->ATLAS(German customs system)
    1)Inbound flow: SAP GTS will send the customs declaration message to ATLAS(German customs system)
    2)outbound flow: response messages from ATLAS(German customs system) approved the customs declaration message and send to SAP GTS
    How to achieve using with SAP PI with Seeburger modules. What are adapter is required for this scenario.
    Idoc coming from SAP GTS to Seeburger BIS and then convert to EDIFACT send to Atlas systeam.
    For mapping  Source is Idoc (CCECUS02) and Target is EDIFACT(CUSDEC_UN_D96B).
    Regards,
    Ramesh

    >
    Ramesh Gulipalli wrote:
    > Hi All,
    >
    > I have scenario this SAP GTS----->SAPPI with Seeburger BIC--->ATLAS(German customs system)
    >
    > 1)Inbound flow: SAP GTS will send the customs declaration message to ATLAS(German customs system)
    > 2)outbound flow: response messages from ATLAS(German customs system) approved the customs declaration message and send to SAP GTS
    >
    > How to achieve using with SAP PI with Seeburger modules. What are adapter is required for this scenario.
    >
    > Idoc coming from SAP GTS to Seeburger BIS and then convert to EDIFACT send to Atlas systeam.
    >
    > For mapping  Source is Idoc (CCECUS02) and Target is EDIFACT(CUSDEC_UN_D96B).
    >
    > Regards,
    > Ramesh
    > .
    for converting an XML to EDI or vice versa you can use the seeburger adapter.
    http://www.seeburger.com/xi-pi-adapters/

  • Problems with Seeburger FTP Receiver adapter

    Hello,
    I am working on a scenario sending ORDERS05 Idocs to EDI vendors.
    For this i have configured Seeburger Receiver FTP adapter with 2 modules to convert XML-EDI format. Since this is the test, I have pointed Seeburger to local FTP server with following settings
    Hostname <Hostname of our FTP server>
    Port <Port # of our FTP server>
    Host Path/VAN partner id <some local directory of FTP server>
    Payload mode: Maindocument.
    At runtime i received following exception
    Message could not be forwarded to the JCA adapter. Reason: Fatal exception: javax.resource.ResourceException: >> Description: com.seeburger.jftp.app.exception.FtpExceptionSoftProcessingError: Unexpected reply: 500 'SITE system 1': command not understood>> Details: com.seeburger.jftp.app.exception.FtpExceptionRethrowError: Error in session: {type:FTPConnectionId}{binding:82ea8d3089dc3e898ae2e608d9d8487d}{channel:a52d1aaa8dd63ff59c2f590e78586a77}{toparty:TestEDIParty} CAUSED BY: com.seeburger.jftp.app.exception.FtpExceptionOpenConnectionError: Error while connection to remote host CAUSED BY: com.seeburger.jftp.app.exception.FtpExceptionRethrowError: Error while executing command QUOTE site system 1 CAUSED BY: com.seeburger.jftp.app.exception.FtpExceptionSoftProcessingError: Unexpected reply: 500 'SITE system 1': command not understood>>SendingStatus: NOT_TRANSMITTED>>FaultCategory: COMMUNICATION_ERROR>>Retryable: true>>Fatal: true
    Few questions related to this
    1] can we use Seeburger adapter to generate EDI files on local FTP server
    2] If not Seeburger can we use normal File adapter to do the same. I tried the same by configuring BIC module in File adapter so that it would convert XML to EDI format and was hoping file to be generated on FTP server. It generated one line XML file with following text "<info>Converted message locates in a attachment</info>". Any idea how to retreive attachments in File receiver adapter (as far as i know no attachments are supported in File receiver adapter).
    Any idea how to generate EDI files with Seeburger FTP on test server?
    Thanks in advance.
    Regards
    Rajeev

    Hi Rajeev,
    > 1] can we use Seeburger adapter to generate EDI files on local FTP server
    Yes we can use.
    > Any idea how to generate EDI files with Seeburger FTP on test server?
    It is like a normal process, how to generate the EDI files in normal means without FTP. Check this link
    https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/10b17369-9522-2c10-84a6-d75d8a8ace22
    BIC
    https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/00b66651-eeea-2b10-e5a6-8459ec30d948
    Regards
    Ramesh

  • Problem in SEEBURGE BIC mapping adapter

    Hi experts
               I am using SEEBURGER MAPPING adapter for file to idoc scenario .I have to convert an input flat file into xml using BIC mapping adapter.The problem is that when i am giving input file to convert into xml ,the conversion is failing with a error that a special character(?) occurs in the begining of file.when we r opening the file then we r not able to see any special character.The file is in UTF16 Little endian encoding. we r unable to find that how the spechial character is coming in the input files and how to debugg it.Plz guide me how to proceed.Is there any function in SEEBURGER to remove special character from the source file?
    Regards
    Neha

    Hi Neha,
    Seeburger is providing Modules (Configurable in CC module chain) described in SAPXI_SeeXIModules_en.pdf with additional functionality like Replace String,Start Local Up, Charset Conversion, zip and dynamic Configuration.
    So if you have those modules installed you can use Replace String functionality to replace this string.
    Regards
    Naycho

  • Problem with Seeburger Message splitter

    I'm doing a Inbound 850 from VAN...but for now I have a sample file which has 2 orders in it and this is the error I get:
    Information Channel fromFile: Send binary file  "/usr/sap/KPX/COMM/EDI/out_split/850_E2X_1.dat", size 2918 with QoS EO.
    Information MP: entering1
    Information MP: processing local module localejbs/CallBicXIRaBean
    Information SEEBURGER BICXIADAPTER.MODULE Message entered Module (CallBicXIRaBean) and will be passed to the adapter now.
    Information SEEBURGER BICXIADAPTER +++ starting conversion with mapping: See_E2X_ANSIX12_850_V4010 +++
    Information SEEBURGER BICXIADAPTER +++ CONVERSION SUCCESSFUL +++
    Information SEEBURGER BICXIADAPTER.MODULE BIC Module (CallBicXIRaBean) is exiting succesfully.
    Information MP: processing local module localejbs/Seeburger/MessageSplitter
    Warning SEEBURGER/MSGSPLITTER: There is no attachment to split. So there is nothing to do.
    Information SEEBURGER/MSGSPLITTER: Finished splitting!
    I have the set the parameterName "split" to true...
    Any idea why its not splitting?
    Thanks,
    Srini
    Edited by: Srinivas Davuluri on May 13, 2009 10:10 AM

    Hi,
    Seeburger responded and added a patch, but now I'm getting this error:
    Information Channel fromFile: Send binary file  "/usr/sap/KPX/COMM/EDI/out_split/850_E2X_1.dat", size 2918 with QoS EO.
    Information MP: entering1
    Information MP: processing local module localejbs/CallBicXIRaBean
    Information SEEBURGER BICXIADAPTER.MODULE Message entered Module (CallBicXIRaBean) and will be passed to the adapter now.
    Information SEEBURGER BICXIADAPTER +++ starting conversion with mapping: See_E2X_ANSIX12_850_V4010 +++
    Information SEEBURGER BICXIADAPTER +++ CONVERSION SUCCESSFUL +++
    Information SEEBURGER BICXIADAPTER.MODULE BIC Module (CallBicXIRaBean) is exiting succesfully.
    Information MP: processing local module localejbs/Seeburger/MessageSplitter
    Information SEEBURGER/MESSAGESPLITTER: Trying to establish CCI Connection to Message Splitter Adapter
    Information SEEBURGER/MESSAGESPLITTER: Creating CCI Interaction
    Warning SEEBURGER/MESSAGESPLITTER: There is no attachment to split. So there is nothing to do.
    Information SEEBURGER/MESSAGESPLITTER: Finished splitting!
    Information SEEBURGER/MESSAGESPLITTER: Message Splitter Module (CallMessageSplitterXIRaBean) is exiting succesfully.
    Information MP: processing local module localejbs/CallSapAdapter
    Information The application tries to send an XI message asynchronously using connection File_http://sap.com/xi/XI/System.
    Information Trying to put the message into the send queue.
    Information Message successfully put into the queue.
    Information The application sent the message asynchronously using connection File_http://sap.com/xi/XI/System. Returning to application.
    Information MP: leaving
    Information File "/usr/sap/KPX/COMM/EDI/out_split/850_E2X_1.dat" deleted after processing.
    Any suggestions??
    Thanks,
    Srini
    Edited by: Srinivas Davuluri on May 14, 2009 11:32 AM
    Edited by: Srinivas Davuluri on May 15, 2009 10:00 AM

  • Seeburger BIC Mapping Designer-Project Explorer.......

    Hi Everyone,
          I have a Problem with Seeburger BIC Mapping Designer. The problem is All the Projects/Mappings that i have done are suddenly disappeared in the Project Explorer, but my projects are available in the C:\Program Files\SEEBURGER\MappingDesigner\user\bicmd folder. I think the file "Project.xml" is refreshed.
    what could be the problem and please suggest me with the suitable solution.
    I am currently using 6.3.2 Version of BICMD.
    Regards,
    Varun Reddy.K
    Edited by: Varun Reddy K on May 7, 2008 4:58 PM

    Hi Seshagiri,
        Thanks for your reply, even i opened and closed it multiple times, but no use.
    Regards,
    Varun.

  • Seeburger BIC vs Informatica Conversion Agent

    Hi Experts,
    I am hoping I can seek some feedback on the above mentioned subject. I am going through an implementation currently which involves EDIFACT and X12 - various message types e.g. Orders, Desadv, Invoice, Order Confirmation and a few more.
    As part of the implementation we need to choose a tool to do EDI to XML conversion which can also do EDIFACT/X12 validations (syntax & semantic) plus a functional Acknowledgment.
    The two final options we have chosen are Informatica's Conversion Agent and Seeburger BIC (given we are using Seeburger FTP adapter for communication already).
    Now to make a final decision I was hoping if some people can share their experience (s) and give some pro's and con's for choosing one or the other please?
    Any comments will be highly appreciated.
    regards

    Hi mimranacc,
    I was hoping if someone can comment on Conversion Agent as well or if there is a white paper on the comparison of the two?
    I have extensively worked on Conversion Agent. My experience has been real good with this tool. It is quite handy and easy to use.
    Apart from unstructured messages from MS Word, PDF, Excel, PowerPoint etc, Conversion Agent can manage semi-structured formats like EDI, HL7, ANSI X12, COBOL and HIPA.
    It consists of set of libraries that are deployed on PI's J2EE server and is accessed by AE during runtime.
    The +ve points are -
    1. Very easy to install and use,
    2. Easily integrated with SAP PI,
    3. No additional adapter required for transformation to / from XML,
    4. No extra adapters installed on PI server, which enhances the performance,
    5. Monitor Conversion Agent messages in Integration Server.
    Unfortunately, I haven't worked with Seeburger BIC, so can't provide you a comparison.
    Hope this helps.
    Regards,
    Neetesh

  • Seeburger BIC Mapping Designer: Special Character (German Umlaut) Problem

    Hi,
    i have created a Mapping with Seeburger Mapping Designer (Invoicd96a to XML). I started the test environment, compiled the mapping and converted the Message to XML. I got a syntax error in the destination file so i added the setSourceEncoding("UTF-8") option and i got a working xml file.
    My problem is that all special characters, will be displayed as ? So the word "Beträge" will be converted to "Betr?ge".
    What i have to di, to fix this problem ?
    Thanks in advance 
    Matthias

    hi,
    i have to create an Edifact to XML Mapping with the BIC Mapping Designer. After creation i can deploy this mapping to SAP XI and calling it by using it as module in the specified adapter.
    My idea is that the mapping should working correct in test enviroment before i deploy to SAP PI.
    Perhaps anyone has an idea.
    regards
    Matthias
    P.S.: A few month ago i had a similar problem with the conversion agent and it was just a "secret" checkbox

  • Seeburger BIC problem

    Hello experts,
    I'm facing a nasty Seeburger BIC problem in my receiver adapter when converting from XML to EDI.
    The error is:
    - SEEBURGER BICXIADAPTER.MODULE Message could not be forwarded from the Module (CallBicXIRa) to the JCA adapter.
    Adapter Framework caught exception: BICMODULE:Adapter call failed. Reason:
    - Delivering the message to the application using connection File_http://sap.com/xi/XI/System failed, due to: com.sap.engine.interfaces.messaging.api.exception.MessagingException: Error in BICMODULE-module:Adapter call failed. Reason: .
    As you can see, the reason is not mentioned.
    When I look into the message monitoring, I see the message does not have a payload. On the SOAP ducument is provided with this content:
    authorization:Basic UElJU1VTRVI6SUQzaW5zdGFsbA== accept-encoding:gzip
    sap-xi-messageid:4BA11A89186666D8E1000000C0A8A310 content-
    length:2916349 host:id3-ma-dwh1.mrco.be:51300 user-agent:SAP NetWeaver Application Server (1.0;711) content-
    type:multipart/related;boundary=SAP_001E0BFD21001DEF8CBF15AFFC885B07_END;type="text/xml";start="" soapaction:"http://sap.com/xi/XI/Message/30"ApplicationMessageasynchronous4ba11a89-1866-66d8-e100-0000c0a8a3102010-
    03-17T19:07:56ZID2CLNT001SteriaVANBC_UTILMDToSteriaVANMDSnapShot_In_AExactlyOnceInformationOffID2CLNT001XI4ba11a89-1866-66d8-e100-0000c0a8a3103.0is.13.id3-ma-dwh1XI4ba11a89-1866-66d8-e100-0000c0a8a3103.0af.id3.id3-ma-dwh1XIRA4ba11a89-1866-66d8-e100-0000c0a8a310MainDocumentApplication
    The Seeburger modules used in my receiver adapter:
    1. localejbs/CallBicXIRaBean -- BIC
    2. localejbs/Seeburger/Zip -- ZIP
    The Module Configuration:
    BIC - destEncoding - ISO8859_1
    BIC - destSourceMsg - MainDocument
    BIC - destTargetMsg - MainDocument
    BIC - mappingName - X2E_....
    BIC - srcEncoding - ISO8859_1
    ZIP - mode - zip
    ZIP - sourceDest - MainDocument
    ZIP - targetDest - MainDocument
    ZIP - zipFormat - gzip
    Messages fail at random. ABAP mapping and data are ok.
    I think there is a problem with capacity or memory or something.
    Anyone any idea?
    Thanks a lot!
    Dimitri

    >
    Dimitri Sannen wrote:
    > Hello experts,
    >
    > I'm facing a nasty Seeburger BIC problem in my receiver adapter when converting from XML to EDI.
    >
    > The error is:
    >
    > - SEEBURGER BICXIADAPTER.MODULE Message could not be forwarded from the Module (CallBicXIRa) to the JCA adapter.
    >
    > The Seeburger modules used in my receiver adapter:
    >
    > 1. localejbs/CallBicXIRaBean -- BIC
    > 2. localejbs/Seeburger/Zip -- ZIP
    >
    Dimitri,
    The reason that you are getting this error is because you are missing the exit module bean. add this module after the zip module
    Processing sequence
    3. localejbs/ModuleProcessorExitBean        Local Enterprise Bean     Exit
    Module configuration
    exit     JNDIName     deployedAdapters/SeeXIAS2/Shareable/SeeXIAS2
    There is an exit entry missing which actually is used to pass the bic data to PI box.
    Regards,
    Pavan

  • BICS Conection problem with prompts

    Hi, All.
    I have one problem with prompts in Webi 4.0. I build BEx query on the Infoset, create OLAP Connection in IDT. And then I try build webi reports appear one problem, I try create prompt on key field, but I cannot do this. Earlier, then I do report on universe I can do this. Can anybody give me advise by this problem?
    Regard.
    Fanil

    Hi Jothi.
    I agree with you but Bex do not allow you to have a restiction to certain values and then a variable on top of that. I have to build the filter in the Webi report and I cannot build it on the description. I have to build it on the key.
    Koos.

  • Mappings_user.sca - Seeburger BIC Mapping Designer

    Hello experts,
    I have read SAP note 1353318 about how to start the BIC adapter on PI 7.1.
    Question: where do I get the file "mappings_user.sca" from? It says it is on the BIC Mapping Designer-CD, but the installation files I received via the Internet - I do not have the CD.
    Can I somehow create that file with the BIC Mapping Designer that I have already installed?
    Thank you for any hint you can give me!
    Best regards,
    Peter

    Hey peter,
                       go to your seeburger installation directorys bin folder and check for bicdesigner.ini file and add the  below cmd
    CmdLnArgX=-ProjectAdmin  where X will be 4 (i.e. count of cmd line agrs used ) .
    Then start the bic mapping designer tool and go to tools option there you can see a new option called Assign Projects to SDA, after that you can create a deploy file..This is new option provided by seeburger bic so that only project Admin can have rights of creating the deploy file.
    If you still face any problems post the same..
    HTH
    Rajesh

  • Can SeeBurger BIC Mapping tool automatically remove Delimiters?

    Hi all,
    When we map IDOC's to EDI X12 messages using the SeeBurger BIC Mapping tool, we sometimes have delimiters occur in fields such as name or address. We are using the setDestinationDelimiter and have changed our delimiters so this occurance is rare. However the problem may still occur. This causes an invalid message to be passed to our partner.
    One option is to use XI mapping and the replace function on each field however this is cumbersome and not the ideal solution.
    Is there a way to automatically remove Delimiter characters from fields as part of the BIC Mapping.
    Cheers,
    John

    Hi Satish,
    Thanks for re-iterating the problem. You are absolutely right that this does cause an invalid message.
    Also thanks for your suggestion regarding asking business not to enter the data, this has been done and as stated the occurences of these delimiters in the fields will be low, usually due to user error.
    We still however want to cater for these occurrences and prevent an invalid message being sent to the partner.
    I'm not sure if you've ever used the BIC Mapping tool and what I'm really looking for is someone with experience in this area to give a solution that works. Anyone out there who can help?
    Cheers,
    John

  • SEEBURGER BIC

    Hi All,
    I have a question regarding Seeburger BIC, I have read thru one of the Blogs (/people/bla.suranyi/blog/2006/06/08/sap-xi-supports-edifact) which tells that Native EDIFACT is converted into XML EDIFACT and the actual mapping is done in SAP XI. When Seeburger BIC has the capability of coversion from ANY to ANY format why it is preffered to do the mapping in SAP XI.
    Can anybody explain what are the pros and cons of using Seeburger BIC for any to any conversion.
    Regards,
    Bharani

    I feel SAP XI is a middleware tool and doesn't have the capabilities for the EDI Mapping
    Without Seeburger there is a possibility for developing of adapter or adapter module for this conversion. Seeburger however provides many other functionalities like monitoring and supporting various protocols.
    mapping in SEEBURGER would be lot more easier in SEEBURGER when compared to SAP XI.
    This is possible. It is not mandatory to use Seeburger with XI. However when you post question in XI forum you will get replies related to Seeburger linked with XI only
    There is a conversion engine present if you purchase Seeburger alone and have no XI associated with it. The problem here is seeburger can change the structure of message but does not have vast support of adapters as XI does. Therefore Seeburger with XI provides the best solution. This would be of your interest
    http://www.seeburger.com/any-to-any/
    Regards,
    Prateek

  • Seeburger BIC mapping error(on changing mandatory fields)

    Hi Experts,
    I am working on IDOC to EDIFACT file scenario with seeburger.
    Earlier my end to end scenario was working fine. I got a requirement to change all the mandatory fields of segment NAD into non mandatory field. To acheive this i changed my Seeburger BIC mapping and target XSD in PI. After this process i create .sca file and ask basis to upload it.
    But after deployment i am getting error in communication channel where i am using BIC mapping. The error is message is quite big, still i am attaching a part of it. Please help
    Message processing failed. Cause: Error in BICMODULE-module:Temporary error: BIC XI Adapter call failed. Reason: 2 errors occured. First error: BICMapping: runMapping() FATAL ERROR: java.lang.OutOfMemoryError: Java heap space (failed to allocate 16777240 bytes) Stacktrace: java.lang.OutOfMemoryError: Java heap space (failed to allocate 16777240 bytes) at java.io.ByteArrayOutputStream.write(ByteArrayOutputStream.java:95) at java.io.BufferedOutputStream.write(BufferedOutputStream.java:105) at sun.nio.cs.StreamEncoder$CharsetSE.writeBytes(StreamEncoder.java:336) at sun.nio.cs.StreamEncoder$CharsetSE.implWrite(StreamEncoder.java:395) at sun.nio.cs.StreamEncoder.write(StreamEncoder.java:136) at java.io.OutputStreamWriter.write(OutputStreamWriter.java:191) at java.io.BufferedWriter.flushBuffer(BufferedWriter.java:111) at java.io.BufferedWriter.write(BufferedWriter.java:212) at java.io.Writer.write(Writer.java:126) at com.seeburger.jucon.dochandler.util.GrammarFileWriter.write(GrammarFileWriter.java:262) at com.seeburger.jucon.dochandler.EdiSegmentData.write(EdiSegmentData.java:234) at com.seeburger.jucon.dochandler.Segment.write(Segment.java:645) at com.seeburger.jucon.dochandler.EdiSegmentData.write(EdiSegmentData.java:390) at com.seeburger.jucon.dochandler.Segment.write(Segment.java:645) at com.seeburger.jucon.dochandler.EdiDocWriter.write(EdiDocWriter.java:367) at com.seeburger.jucon.dochandler.InhouseDocWriter.flush(InhouseDocWriter.java:884) at com.seeburger.jucon.mapping.Mapping.run(Mapping.java:2429) at com.seeburger.jucon.seebicapi.BICMapping.runMapping(BICMapping.java:1724) at com.seeburger.jucon.seebicapi.BICMapping.run(BICMapping.java:2518) at com.seeburger.jucon.seebicapi.BICMapping.startSyncMapping(BICMapping.java:1415) at com.seeburger.bicxiadapter.CCIInteraction.convert(CCIInteraction.java:1201) at com.seeburger.bicxiadapter.CCIInteraction.convertCalledFromModule(CCIInteraction.java:911) at com.seeburger.bicxiadapter.CCIInteraction.execute(CCIInteraction.java:313) at com.seeburger.xi.api.cci.impl.nw71.SeeXIInteractionProxy71.execute(SeeXIInteractionProxy71.java:86) at com.seeburger.bicxiadapter.module.CallBicXIRaBean.process(CallBicXIRaBean.java:384) at com.seeburger.xi.api.module.impl.nw71.SeeModuleAdapter71.process(SeeModuleAdapter71.java:78) at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method) at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39) at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25) at java.lang.reflect.Method.invoke(Method.java:585) at com.sap.engine.services.ejb3.runtime.impl.RequestInvocationContext.proceedFinal
    java.security.AccessController.doPrivileged(Native Method) at com.sap.engine.core.thread.impl3.SingleThread.execute(SingleThread.java:169) at com.sap.engine.core.thread.impl3.SingleThread.run(SingleThread.java:266) DESCRIPTION: BICMapping: FATAL ERROR: Internal Fault. Class could not be load or instatiated. Check Installation, access rights. Last error: java.lang.OutOfMemoryError: Java heap space (failed to allocate 16777240 bytes)
    Regards,
    Shradha

    Hi,
    Even I faced a Similar problem...
    1) make sure that the size of the data that is coming to BIC map is not larger than the size defined in the Source field (Check In BIC and SAP XI/PI map.
    2) Make sure id any other seeburger mapping are working fine , This is because you have to deploy the file in form of Active mapping.sca in SAP XI/PI after the changes are made on BIC side.
    3) Check the Adapter Engine Cache ...
    Hope this helps..
    Regards,
    Sainath Chutke

  • Problem with READ Statement in the field routine of the Transformation

    Hi,
    I have problem with read statement with binary search in the field routine of the transformation.
    read statement is working well when i was checked in the debugging mode, it's not working properly for the bulk load in the background. below are the steps i have implemented in my requirement.
    1. I selected the record from the lookuo DSO into one internal table for all entried in source_packeage.
    2.i have read same internal table in the field routine for each source_package entry and i am setting the flag for that field .
    Code in the start routine
    select source accno end_dt acctp from zcam_o11
    into table it_zcam
    for all entries in source_package
    where source = source_package-source
         and accno = source_package-accno.
    if sy-subrc = 0.
    delete it_zcam where acctp <> 3.
    delete it_zcam where end_dt initial.
    sort it_zcam by surce accno.
    endif.
    field routine code:
    read table it_zcam with key source = source_package-source
                                                 accno  = source_package-accno
                                                 binary search
                                                 transportin no fields.
    if sy-subrc = 0.
    RESULT  = 'Y'.
    else.
    RESULT = 'N'.
    endif.
    this piece of code exist in the other model there its working fine.when comes to my code it's not working properly, but when i debug the transformation it's working fine for those accno.
    the problem is when i do full load the code is not working properly and populating the wrong value in the RESULT field.
    this field i am using in the report filter.
    please let me know if anybody has the soluton or reason for this strage behaviour.
    thanks,
    Rahim.

    i suppose the below is not the actual code. active table of dso would be /bic/azcam_o1100...
    1. is the key of zcam_o11 source and accno ?
    2. you need to get the sortout of if endif (see code below)
    select source accno end_dt acctp from zcam_o11
    into table it_zcam
    for all entries in source_package
    where source = source_package-source
    and accno = source_package-accno.
    if sy-subrc = 0.
    delete it_zcam where acctp 3.
    delete it_zcam where end_dt initial.
    endif.
    sort it_zcam by surce accno.
    field routine code:
    read table it_zcam with key source = source_package-source
    accno = source_package-accno
    binary search
    transportin no fields.
    if sy-subrc = 0.
    RESULT = 'Y'.
    else.
    RESULT = 'N'.
    endif.

Maybe you are looking for

  • Problem with SuperDrive in my MacBook Pro

    When I put a CD into my MacBook Pro's optical drive it tries to read it, then spits it out. When I try to put it in again it won't even go in all the way (it bounces out without being pulled in). What diagnostics/maintenance can I do on it before dec

  • PPR and af:InputFile Double Browse

    Hi All, Background: I have an application that uses PPR to upload a file and display the file's content in a textarea. Problem: Performing consecuitive uploads causes a javascript error. Upload 1) Uploads a file successfully, Upload 2) results in a j

  • Do load test for application installed in Weblogic 10.3.4 using OATS 9.31

    Hi Friends, I need to do a load test for my application deployed in Weblogic 10.3.4. I went on to use the Oracle Application testing Suite (OATS 9.31). But it says its compatible only upto Weblogic 10.3.3. So pls advice me to find a way to load test

  • JPanel receives no width or height, but only when run as part of applet

    Applet: http://mazz0.com/drawing/index.html JAR: http://mazz0.com/drawing/DrawingGame.jar Source: http://mazz0.com/drawing/060107/DrawingGame.java This java applet I have written works fine as a standalone application, but when I run it as an applet

  • Undo view hidden folders & files

    hi i had a problem where i was downloading to an external hard drive called storage. i downloaded a file with out the hard drive on so mac put this file on the mac hard drive in a folder called storage, but it has hidden. i googled how to view hidden