Problems with write to measuremen​t file

My VI doesn't seem to write my signal properly when writing is enables.. however, if i change the "Write to measurement file" Express VI to a Write to Spreadsheet function, the signal is written correctly. From what I understand in previous discussions, there is a bug associated with enabling a write to measurement file, so is there a way to enable write to spreadsheet instead of using the express VI or is there a way I can bypass this bug?
Thanks,
TFlax
Attachments:
Analog test and collection.vi ‏700 KB

This is my second program ever written, first in matlab, so I am very new to the field. So why I choose one way over another I have no reasoning, all I know is that it works. I am collecting electromyography analog signals, with a range of +/-5V.. the "bad" writing with write to meas file is that I am getting a flat signal (range between -.01 to +0.01, give or take).. where when written with write to spreadsheet, the signal has proper voltage range and normal frquency and amplitude characteristics seen in EMGs.
I tried using a case structure for the write to spreadsheet, however it only writes the buffer size during continuous sampling. I need it to write the entire time the boolean (enable button) is true, also the enable button is operated as switch when pressed.
The discussion about the write to measurement file: http://forums.ni.com/ni/board/message?board.id=170​&message.id=454380
Thanks again

Similar Messages

  • Problem with write key VIs (config-file)

    Hi
    My problem is this: when I use the write key VIs to write to an ini-file, the values are not written/updated in the ini-file. Does
    anybody has a solution???
    thank YOU!!!
    Attachments:
    writetest.vi ‏32 KB

    astroboy wrote:
    Hi Dennis, writing key updates or add lines, but the problem is that it also causes all lines to be clumped together, making it unreadable.
    What's the better way?
    Clement
    I was complaining about the poor formatting of the .ini files myself a couple years ago in this thread. http://forums.ni.com/ni/board/message?board.id=170&message.id=273552
    I found the offending piece of code was buried pretty deep in the Config File VI hierarchy.
    One idea is to go back after the file is written and find where all the section headers are and insert your own blank lines.
    Also look at this thread http://forums.ni.com/ni/board/message?board.id=170&view=by_date_ascending&message.id=408776
    You may also want to add kudoes to the config file idea in the Idea board.  http://forums.ni.com/t5/LabVIEW-Idea-Exchange/Comments-in-configuration-file-ini/idi-p/927874#A614 
    Message Edited by Ravens Fan on 09-17-2009 10:29 PM

  • Problem with windows not liking any files named prn

    I recently found a problem with windows not liking any files
    called prn.html, prn.cfm etc etc. If you try and create a file like
    prn.html then it will say "File already exists".
    I initially thought it was a Cold Fusion error as I was
    getting some bizarre error messages when trying to write prn.html
    using cffile.
    Does anyone know a work around for it?

    Hi,
    Not only "prn" but also for the terms like "AUX", "NUL" you
    can't create any directories or files in Windows because these are
    reserved terms with Windows which is meant for some device
    drivers...

  • Problems with multiple idocs in one file ( Inbound file )

    HI,
    Thanks in Advance for your suggestions.. Highly appreciated.
    We have problems with multiple IDocs in one file.
    We are using XIB ( Amtrix ) as Middleware to receive the files.
    Curretenly When the file contains one IDoc then there is no problem. IDoc is created and everything is ok.
    If file contains two IDocs ( for example two messages ORDERS and DELVERY ) then it is creating two IDocs but both IDocs contains ORDERS plus DELIVERY segements information. That is the problem. Some how SAP unable to differentiate the IDocs in the file.. But it knows that how many idocs are there in the file..because it is creating exact number of idocs.
    We are using TRFC port ... Do I need to change it to File port..
    When we have more than one idoc do we need set any parameter in the file ...

    Thanks for the swift response. Always ideas are useful.
    As of now , Middleware cannot split the file.
    Thing is SAP is creating two Idocs with different message types. Problem is First IDoc contains ORDERS message type but also DELIVERY segments as well. Second IDoc with DELIVERY message tyoe but ORDERS segments as well... This is the problem... I think we are missing some field activation in file for EDIDC record.
    As far as I know file port supports the number of IDocs in one file.. Hope TRFC port also supports that

  • Strange problem with linking to external vob-file

    I have a strange problem with linking to external vob-file. I
    have created a link using BudApi:
    on mouseup
    set OK = baOpenFile ( the pathname &
    "Files\General\Video\VTS_01_1.VOB", "normal")
    end
    This code opens mpg-videos correctly, but nothing happens
    when I try to open vob-files with the same code. The strangest
    thing is that when I change the default program for vob-files to
    WinDVD this code works and the file opens, but when I change the
    default program to Nero Showtime this code doesn't do anything
    (when I open the file 'manually' from the folder, it opens
    correctly on Nero Showtime). My client uses Nero Showtime, so I
    really would appreciate any help on this one.

    temes wrote:
    >
    quote:
    Originally posted by:
    Newsgroup User
    >> When using Nero Showtime as a default program, the
    error code is 31,
    >> "There is no application associated with the given
    filename".
    >
    > Which suggests that something has gone wrong with file
    associations.
    > If
    > you double-click one of these files in an Explorer
    window does it fire
    > up Showtime and open the file?
    >
    >
    > Yes, the file opens correctly in Nero Showtime when
    double-clicking
    > it in an Explorer. I tried the file associations and
    created a
    > html-page with a link to the vob-file, and the html-link
    opens the
    > vob-file correcly with Nero Showtime. My client reported
    this
    > problem, so it's not just my computer which is having
    this problem.
    If you open a command prompt, do you get an association
    listed like this
    example for .txt files:
    C:\>assoc .txt
    .txt=txtfile
    C:\>ftype txtfile
    txtfile="D:\Program Files\JGsoft\EditPadLite\EditPadLite.exe"
    "%1"
    Andrew

  • Problem with Write To Measurement File Express VI not writing to file if file was deleted after the first call (7.1)

    I'm using the Express Write to LabVIEW Measurement File in LV7.1.
    I have it set to "Save to one file"  and have tried both "Overwrite file" and "Using next available file name" for the "If a file already exists" conditions.
    The path/filename is passed into the function.
    It works fine the first time around.  If the file is deleted before the function is called again, an error occurs since LV is unable to find the file.
    I have had to stop and re-run my program in order to write to use the function again.
    Since I am able to delete the file I assume it was closed but it seems like LV expects it to be there, even though the function was supposed to create/open/close the file...  Is there any way to reset this without stopping/restarting the program?
    Since my application creates several files (only one using the Express VI) I am checking for the filenames and requiring that they be deleted (or a new filename be used) before acquiring data.  Everything has worked great, except for the Express VI.
    Thank you,
    David

    Ok, I've edited the VI you posted to reproduce my error (this time with 8.0). 
    I added a "master stop" and "start log" button.  To demonstrate my problem:
    1.  Run the VI
    2.  Click "START LOGGING" - c:\test.txt is created
    3.  Click "STOP" - c:\test.txt is closed
    4.  Delete the file c:\test.txt with Windows shell or explorer
    5.  Click "START LGGING" - a new c:\test.txt file should be created but instead an error is raised in the Write LabVIEW Measurement File function.
    Any ideas?
    Thanks,
    Dave
    Attachments:
    Write LV Meas File 2.vi ‏96 KB

  • Data format problem with Write to Spreedsheet File

    I have a problem with the data format with Write to spredsheet file.
    I have an N*3 array, where the 3 elements in each row should has different length. When I used Write to spreedsheet file,
    it can only save the three data in one format. How can I save them in the format of "%0.8f %0.3f %0.2f"?
    Thanks for your help.

    Hi powerplay,
    another solution may be to convert column-wise using "number to fractional string", then interleaving resulting arrays and again using "array to spreadsheet string" (with "space" as separator).
    Many ways lead to Rome
    Best regards,
    GerdW
    CLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 on WinXP+Win7+cRIO
    Kudos are welcome

  • Problem with importing saved .json backup file in fresh installed firefox 3.6.8? Message "unable to process the backup file", when i choosed option "Restore" from menu "organize your bookmarks" !?

    Hello,
    my problem is with importing saved .json backup file in fresh installed firefox 3.6.8? Message "unable to process the backup file", when i choosed option "Restore" from menu "organize your bookmarks" !?
    Normally that i followed all instructions from your support site, and that i tried many things, but nothing helped :( !?
    my .json file isn't corrupted cause it was saved on another partition before formatting my OS.
    Please don't tell me that my bookmarks are lost :( cause i had many important things in that bookmarks, on 100.s pages :( ....
    Thanks in advance!
    Sincerely,
    hoho33

    "
    Can you restore that JSON backup in a new profile?
    Did you make sure that it is really a JSON backup and that there is no missing or hidden other file extension?
    A JSON backup starts with: {"title":"","id":1,"dateAdded"
    A HTML backup starts with: <!DOCTYPE NETSCAPE-Bookmark-file-1>
    You can try if you can restore that JSON backup in a new profile.
    Create a new profile as a test to check if your current profile is causing the problems
    See Basic Troubleshooting: Make a new profile
    If that new profile works then you can transfer some files from the old profile to that new profile (be careful not to copy corrupted files)
    See http://kb.mozillazine.org/Transferring_data_to_a_new_profile_-_Firefox
    Please for administration of this support site, make possibility to quote someone's answer, on this way is dificult to answer somebody who wrote some suggestion!
    No, i can't restore JSON backup in new profile, even on fresh installed OS XP SP3, with fresh installation of latest version of firefox!
    MAN I TOLD YOU 10X IT'S 200 % JSON BACKUP FILE!!! I'M NOT IN IT FROM YESTERDAY, I WORK IN IT 12 YEARS!!!
    I tried restoring json backup in new profile, but nothing, i couldn't restore, cause that stupid error from screen shot which i posted again appears !
    Man i'm not totally noob i repeat 2nd time here, and normally that i know to create new profile, and that i tried that, but that didn't help!
    I can't believe that FIREFOX has not good support team, and doesn't care for yours users, this will not give me more reason to use in future firefox
    like borwser, if i don't have good support, and when i have problem like this, to loose all my very important bookmarks and passwords on them, and
    firefox support won't to help me to solve my problem!
    If somebody from firefox support team read this, i can give you Remote desktop access to my computer to try solve this problem, like other serious company
    like HP, Dell , etc. give remote desktop support to their users!
    Corel are you from firefox support team? Please don't write same suggestions, cause i know to read, and i understand well if you write once some suggestion!
    Greetzz

  • Improving Write to Measuremen​t File Rate

    Hello again everyone,
    I was wondering if I could once again get some help with my VI which is dealing with data aquisiton, display and logging. I'm attempting to display and record all the data that is incoming serially from some external ADC boards. The data is received at 500Hz and I am trying to currently record this through the use of Write to Measurement file, however i'm finding that I am not recording all the data that is captured into the file. When I tested this code I found I was only getting a recorded sample rate of about 3Hz... I'm looking to reach at least recording the data at 50Hz minimum, however i'm having trouble figuring out how.
    I currently have a global loop with a delay of 100ms, however reducing this increment did not noticeably increase the rate at which the data is recorded. I suspect it is due to the time taken to carry out everything within the loop, however I don't know how to improve this, using a different structure perhaps? If someone could take a look at my VI and give me some pointers on how to improve the cycle rate that would be awsome.
    Also, I find that the display is quite laggy in displaying the incoming data. Again this wasn't improved by changing the delay in between the loops or selecting the synchronous display option. The delay in inputing data at the ADC and seeing the result on the screen was somewhere around 1 second!
    Any help would be greatly appreciated as I don't know how to sort this problem out.
    Thanks in advance!
    Stirling
    Attachments:
    Serial read v2.2.vi ‏136 KB

    Hi Stirling,
    I don’t think it’s a problem with the Write to Measurement
    File.vi. You need to have a look at the VISA Read.vi. You are reading 5K at
    every iteration of the loop and that could probably be causing the delay. A
    great way to troubleshoot this would be to turn on highlight execution.
    Also, you should consider using the Array to Cluster.vi and
    the Convert to Dynamic Data.vi in the Write to Measurement File.vi block. This
    shouldn’t effect anything; just a suggestion to take advantage of LabVIEW functions.
    Adnan Zafar
    Certified LabVIEW Architect
    Coleman Technologies

  • Write to measuremen​t file help

    Hi,
    I am a beginner. I am working on a VI.
    But have some problems that I couldn't solve.
    Here is the VI attached, I get on the output the positive and negative peak values which I then write to a mesurement file.
    But now I just get my last values of positive and negative peak in the measurement file.
    But I there were different values before that last values also. I want to save all the values, or every time that values changes on postive and negative, I would like to save all values to a file.
    Would be great if someone can help me with it.
    Regards,
    Raj
    Attachments:
    VI_HELP.vi ‏103 KB

    If you did the TDMS file your self (not use the express VI).  Then you could specify the group to write into and the channels.  It sounds like you want to add new channels each time you acquire a set of samples.  Look in the example finder (Help->Find Examples) for TDMS Write Triggered Data.vi.  It looks like a decent example to get you started.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • System time in Write TO Measuremen​t File

    Hi, everyone. I'm Sorin.
    I use a DAQ 6210 in Labview 8.2 to aquire some analog data at 1 sec,and i have 2 questions, please:
    1. I need to record the data into a file .lvm, so i use "Write TO Measurement File" module with one column of time (X axe). But this time is relative, and i want to be system time instead. Is there any way to resolv that ?
    2. Also, in my Waveform Chart i put absolute time because i couldn't find system time, though i need it. How can i change that ? Although, once i played with charts, and i succeeded to see system time, but now i can't. And i'm sure it wasn't complicate. 

    Hi Sir
    I had similar problem. I tried to write to a measurement file with absolute time, instead of relative time here I got.
    Also, I want the format to be sth like this 13/09/25 18:16:01.
    Could you help me?
    Thanks
    LabVIEW Measurement
    Writer_Version 2
    Reader_Version 2
    Separator Tab
    Decimal_Separator .
    Multi_Headings No
    X_Columns Multi
    Time_Pref Absolute
    Operator FriedmanLab
    Date 2013/09/25
    Time 14:09:10.2151017189025878906
    ***End_of_Header***
    Channels 1
    Samples 1
    Date 2013/09/25
    Time 14:09:10.2151017189025878906
    X_Dimension Time
    X0 0.0000000000000000E+0
    Delta_X 1.000000
    ***End_of_Header***
    X_Value Untitled Comment
    0.000000 21.787387 Enter a description
    10.000572 21.847446 Enter a description
    20.001144 21.841562 Enter a description
    30.000716 21.908628 Enter a description
    40.001288 21.902826 Enter a description
    50.004860 21.963112 Enter a description
    60.035434 21.967730 Enter a description
    70.031005 21.968933 Enter a description
    80.011576 22.039718 Enter a description
    90.000148 22.065121 Enter a description
    wei shen
    Attachments:
    Untitled.jpg ‏74 KB

  • Attach labels for write to measuremen​t file and graphing

    I am currently having alot of problems with attaching labels to double type of wires and changing the label attached to the dynamic type of wires. I want the write to measurement file to have the correct headings but the current headings for the columns are displaying untitled or change the heading for the dynamic type of wire. I attached a picture of the program and I would be very grateful if anybody knew how to change these headings.

    Try this VI I made. It takes in a Double signal and a string, names your signal, and outputs it as a Dynamic Data.
    I used this with the Write to Measurement File without any issues!!!
    To name a Dynamic Data Signal, use the Set Dynamic Data Attributes VI found in Express > Signal Manipulation
    Hope this helps,
    Cheers
    Attachments:
    Name DBL Signal VI.png ‏59 KB
    Name DBL Signal for Measurement File.vi ‏35 KB

  • Problems with write latency

    Hi to all storage gurus,
    One of our disk systems (HP EVA8000) has been quite busy lately. HP has
    spent days analyzing the situation and the result of the analysis was
    that the disk system is ok but there are occasionally up to 2000 ms
    write latencies. According to them this is not out of ordinary and
    operating systems should be able to handle the situation.
    The problem is that Netware seems not always to be able to handle such
    write latencies and the clustered services may go to comatose when the
    write latency is so high. This does not happen on every such occasion,
    but too often anyways. Netware is the only operating system which has
    any problems with our EVA8000. In this particular EVA we we have roughly
    200 hosts, out of which about 10% are Netware. Thus is seems rather
    clear that something is wrong with our Netware setup or Netware itself,
    we just dont have any clues what.
    All servers have NW6.5 SP8, and HP supported Qlogic HBA's with latest HP
    supported bios and drivers.
    In our Startup.ncf we have:
    set multi-path support=on
    LOAD SCSIHD.CDM AEN TOFACTOR=5
    LOAD QL2X00.HAM SLOT=201 /LUNS /ALLPATHS /PORTNAMES /MAXLUNS=12
    /XRETRY=400 /XTIMEOUT=60 /BACKOFF
    LOAD QL2X00.HAM SLOT=202 /LUNS /ALLPATHS /PORTNAMES /MAXLUNS=12
    /XRETRY=400 /XTIMEOUT=60 /BACKOFF
    The error messages are as follows:
    18.06.2009 15.30.14 : COMN-3.27-34
    Severity = 5 Locus = 2 Class = 6
    NSS-2.70-5005: Volume KOTI12/USER2 user data write
    (20204(zio.c[2301])) to block 122610663(file block 4810)(ZID
    146302323) failed.
    18.06.2009 15.30.15 : COMN-3.27-1092
    Severity = 4 Locus = 3 Class = 0
    NSS-3.00-5001: Pool KOTI12/SARKA is being deactivated.
    An I/O error (20204(zio.c[2279])) at block 29505990(file block
    104772)(ZID 3) has compromised pool integrity.
    Any ideas what could be wrong?
    Best regards,
    Jonne Viljanen
    University of Helsinki

    Hi JJ,
    Thanks for your insightful answer. We are using execution throttle 16 on
    almost all hosts. However HP suggested to increase the execution
    throttle on Netware hosts to 64, since their IO to disk system is very
    small and thus increasing the value would not cause problems to other
    hosts. Increasing the execution throttle did not solve our problems.
    What value are you using for execution throttle?
    Cheers,
    JV
    > Hi,
    >
    > We had some similar problems (many hosts on an EVA 8000) but only with a
    > disk failure. A disk failure causes latency and thus resulting in node cast
    > out, comatose services or dismounted volumes. And since a san is still is a
    > shared disk system /EXECTHROTTLE might be something to look into. If a
    > couple of hosts have the execution throttle set to high (like 256) then they
    > will fil up the controllers queues first leaving no room for other hosts.
    > We also we played around with the /XTIMEOUT parameter. but not as high as 60
    > (ours is 8 on a 8 node cluster) because the cluster software also needs some
    > time to make a good judgement.
    >
    > Cheers,
    > JJ
    > .
    >
    >
    >
    >
    > "Jonne Viljanen" <jonne.viljanen@rmv_this.helsinki.fi> wrote in message
    > news:[email protected]...
    >> Hi to all storage gurus,
    >>
    >>
    >> One of our disk systems (HP EVA8000) has been quite busy lately. HP has
    >> spent days analyzing the situation and the result of the analysis was that
    >> the disk system is ok but there are occasionally up to 2000 ms write
    >> latencies. According to them this is not out of ordinary and operating
    >> systems should be able to handle the situation.
    >>
    >> The problem is that Netware seems not always to be able to handle such
    >> write latencies and the clustered services may go to comatose when the
    >> write latency is so high. This does not happen on every such occasion, but
    >> too often anyways. Netware is the only operating system which has any
    >> problems with our EVA8000. In this particular EVA we we have roughly 200
    >> hosts, out of which about 10% are Netware. Thus is seems rather clear that
    >> something is wrong with our Netware setup or Netware itself, we just dont
    >> have any clues what.
    >>
    >> All servers have NW6.5 SP8, and HP supported Qlogic HBA's with latest HP
    >> supported bios and drivers.
    >>
    >> In our Startup.ncf we have:
    >>
    >> set multi-path support=on
    >> LOAD SCSIHD.CDM AEN TOFACTOR=5
    >> LOAD QL2X00.HAM SLOT=201 /LUNS /ALLPATHS /PORTNAMES /MAXLUNS=12
    >> /XRETRY=400 /XTIMEOUT=60 /BACKOFF
    >> LOAD QL2X00.HAM SLOT=202 /LUNS /ALLPATHS /PORTNAMES /MAXLUNS=12
    >> /XRETRY=400 /XTIMEOUT=60 /BACKOFF
    >>
    >>
    >> The error messages are as follows:
    >>
    >> 18.06.2009 15.30.14 : COMN-3.27-34
    >> Severity = 5 Locus = 2 Class = 6
    >> NSS-2.70-5005: Volume KOTI12/USER2 user data write
    >> (20204(zio.c[2301])) to block 122610663(file block 4810)(ZID 146302323)
    >> failed.
    >>
    >> 18.06.2009 15.30.15 : COMN-3.27-1092
    >> Severity = 4 Locus = 3 Class = 0
    >> NSS-3.00-5001: Pool KOTI12/SARKA is being deactivated.
    >> An I/O error (20204(zio.c[2279])) at block 29505990(file block
    >> 104772)(ZID 3) has compromised pool integrity.
    >>
    >>
    >> Any ideas what could be wrong?
    >>
    >>
    >> Best regards,
    >>
    >> Jonne Viljanen
    >> University of Helsinki
    >
    >

  • Problems with write to measurement

    My project group has some problems with the write to measurement VI.
    Firstly, for each of the SOC/Voltage...each file only has one value, how to make all value inside one file?
    Secondly,How to make all the different  parameters, such as SOC1, SOC2, Voltage1, Voltage2, appear in one excel file for easier reference?
    Attachments:
    TwoBatteries.vi ‏246 KB

    Look at your settings for the Write to Measurement File.  You are telling it to save to one file, and then use next available filename.  Try append to file.
    Also, use Merge Signals to combine the 4 and write to a single Write to Measurement File.  Right now you have 4 identical ones with the same file name.  They are stepping all over each other.
    When using the Write to Measurment File, try opening up the help file and reading it o understand what each setting does.

  • Problems with spaces in directory or file names and Word.exe

    Hi
    I'm trying to open a file with Word from my java aplication, and I have a problem with some file/directory names.
    I have this
    String cmd = "c:\\Program Files\\Microsoft Office\\Office10\\WINWORD.EXE" + " " + path;
    try {
    Runtime.getRuntime().exec(cmd);
    } catch (Exception errorea){ }
    Here is what happens:
    if path is something like this: "c:\people\info.doc" , there's no problem, Word opens the document, but if path contains blank spaces somewhere, it doesn't work. For example:
    path = "c:\Documents and Settings\info.doc"
    path = "c:\Hi everybody\info.doc"
    path = "c:\tests\test results.doc"
    with the above examples it doesn't work :( Word tries to open "c:\Documents", "c:\Hi" or "c:\tests\test".
    Can anyone help? thanx a lot ! : )

    No, the exec method runs the Word.weird, it shouldn't, and it wouldn't on my system going by the test I just made, but I'm running linux & not windows, maybe the command line parsing is different for some reason.
    The problem is that
    Word starts and then Word says that it can't open the
    file because the name or the path to the file is not
    valid.You still should use the overload that takes a String array.

Maybe you are looking for