Rejections during in-process inspections
hi, is any std report available to find what are the produts rejected during in-process inspection,(at which operation) against each prod order? also can we know how many products passed without defect (after in-process insp) during in-process inspection against prod order?
Dear,
Do the defect recording at that time craete automatic notification then you will get this report in QM10 and QM11.
Else use the report QA33.
Regards,
R.Brahmankar
Similar Messages
-
Sampling Inspection at variable rate during Receiving process
Hello,
We would like to perform sampling inspection during receipt process, actually we perform sampling for couple of supplier, the QA procedure is to inspect 10% of the total qty( we don't have lot/serial control set for items), if any failure then need to increase sampling rate to another by 10%.
As I understand Quality module in 11.5.10 allows for sampling at receiving process. But I am not sure, does it allow for above requirement to perform at different sampling rate based on failure.
Looking forward for your expert comments.
Thanks,In quality module, you can setup rules that can alter the sampling rate. It is called skip lot inspections.
e.g. you can say that
* inspect 1 in every 5 shipments.
* But if any shipment is found bad, inspect 3 in every 5 shipments.
* Once 10 consecutive inspections are successful, then revert back to 1 in every 5 shipments.
Keep in mind the functionality works on number of receipts - not quantity in each receipt.
First you have to enable your org for skip lot inspections
Then you define a skip lot process code. This is where you define your logic/rules.
Then setup your sampling collections plan.
Hope this answers your question
Sandeep Gandhi
Omkar Technologies Inc.
Independent Techno-functional Consultant -
In-process inspection for rework operation
Hi all,
i have a production order to which the in-process inspection characteristics are assigned in routing. when a production order is released, an in-process inspection lot is created. Inspection is carried after the end of an operation. During which rework will be carried out if the product is rejected. Rework operations are trigged through trigger points assigned to the production order. A reference operations set indicating the rework operations is assigned to the trigger point. rework operation in the reference opeation set is also assigned with inspection characteristics. But during the results recording, the rework inspection characteristics are not displayed for results recording.....
pls explain the possible solution.
regards,
sravan kumar vHello
I think that the process can be mapped in one of these ways:
- according to what you describe this is closer to a good receipt inspection and not to in-process inspection, as the trigger for the inspection is the GR and not the release of the order. So, why dont you give a chance to a 04 inspection type, with inspection lot creation for every GR ? Check the indictor in MM02, QM view for "04" inspection, and uncheck the "Stock in quality", so you dont get caught by the stock in quality and resembles in process "Non-stock relevant" inspection
- alternatively you can define the use of inspection points ? So you are adding new results as new confirmations are made. Disadvantage: you can only give one usage decision to the inspection Lot, irrespective of the number of samples you have analyzed.
Regards -
Rejected material in quality inspection
Dear Guru's,
Is there any report to find out the rejected quantity in quality inspection with reference to the GR and PO.
Rgds,
cherukuriDear Guru,
we can generate or standard reports are available.
If u tell me the processes how u feed the data for rejections , i can give a better solution.
two methods are there
1) Notifications
2) GR Processes
more clarity is required.
shridhar
9880644496 -
Production order should be confirmed before in-process inspection UD
We guys,
I have activated the In-process inspection for one Finished goods and inspection lot is getting created when Production order released. This production order can be confirmed without UD for In-process inspection lot.
Please let know How can I control that Production order should not be able confirm before UD of Inspection lot for in-process inspection.
When production order released it means an production has just starded. Then What is the meaning in getting the inspection lot created on release of production. I think it is supposed to be on completion of each opration.
Please give your inputs.
Thanks
DhanuHello
inprocess inspection are used to assisst you to record results , defect , rework, during the production operation. It is defined to get created during the release of the order. It gives QM personnel a control over the quantity confirmation. You can do the result recording based on time and quantity.
Operation confirmation and UD are independent and it will not be possible to do confirmation once you do the UD.
The controls that can be brought in 03 inspection for a better usage
1) Result recording mandatory for all inspection points
2) QM operation can be confirmed only by QM personnel
3) At the time of GR of the order check whether UD for the lot is given. Make UD mandatory for GR of the order
4) Only after QM operation confirmation the next operation can be confirmed
5) make use of Rework to capture rework cost and First Pass Yield
Hope this gives some picture to you
Regards
gajesh -
i tryed to restore my phone but it turn off during the process and an error happens so should i do ?
Hello there, VladlsSwag.
The following Knowledge Base article provides some steps for troubleshooting your issue:
iPhone: Hardware troubleshooting
http://support.apple.com/kb/ts2802
Particularly:
Will not turn on, will not turn on unless connected to power, or unexpected power off
Verify that the Sleep/Wake button functions. If it does not function, inspect it for signs of damage. If the button is damaged or is not functioning when pressed, seek service.
Check if a Liquid Contact Indicator (LCI) is activated or there are signs of corrosion. Learn about LCIsand corrosion.
Connect the iPhone to the iPhone's USB power adapter and let it charge for at least ten minutes.
After at least 30 minutes, if:
The home screen appears: The iPhone should be working. Update to the latest version of iOS if necessary. Continue charging it until it is completely charged and you see this battery icon in the upper-right corner of the screen . Then unplug the phone from power. If it immediately turns off, seek service.
The low-battery image appears, even after the phone has charged for at least 20 minutes: See "iPhone displays the low-battery image and is unresponsive" symptom in this article.
Something other than the Home screen or Low Battery image appears, continue with this article for further troubleshooting steps.
If the iPhone did not turn on, reset it while connected to the iPhone USB power adapter.
If the display turns on, go to step 4.
If the display remains black, go to next step.
Connect the iPhone to a computer and open iTunes. If iTunes recognizes the iPhone and indicates that it is in recovery mode, attempt to restore the iPhone. If the iPhone doesn't appear in iTunes or if you have difficulties in restoring the iPhone, see this article for further assistance.
If restoring the iPhone resolved the issue, go to step 4. If restoring the iPhone did not solve the issue, seek service.
My issue is still not resolved. What do I do next?
Contact Apple Support.
Thanks for reaching out to Apple Support Communities.
Cheers,
Pedro. -
COA's with In-process Inspection & w/o Batch Management
Hi Folks,
We are doing in-process inspection in our system, for production. Also, we donot use batch management. Yet, we've COA's that need to be generated on our finished products before their dispatch to the customers.
I've previously used COA's in a Batch Managed & GR Inspection (type 04) scenario. Not sure if COA's can be generated for my scenario (in-process inspection & no batch mgmt). Would like to take suggestions from you experts on how do I approach this.
Thanks
AnandI believe you should be able to generate COA's using the 03 inspection results, but... I've never tested it or tried to do it. But in using 03's there are some issues that you'd have to check on and test out.
I don't think you'll be able to have the same test in the inspection lot more then once. This can happen if you run the same test at different operations of the process. Such as water content which might be tested several times during production. You might also have some issues if you use inspection points. I think it will use the last test result regardless of inspection points. But I'm not 100% sure on that.
You will also to need to make sure there are UD's on the inspection lot. You'll probably want to run the Auto UD for production lots and have it close all lots where the order has a TECO status.
Other then those cautions, it should work similarly to reporting results from an 04 inspection lot.
Craig -
In-Process Inspection material having inspection type 04
Dear Sir/Mam
My question.In-Process Inspection material having inspection type 04.As we accept the inspection lot we put the stock into unrestricted.But when we have to reject we convert that stock into new material or if rework to be carried out,the criteria is stock should be quality,than production people cancel the confirmation and rework is carried out through trigger point.So my concern can we put the stock in block and in background whole production order is cancelled.
Thanks
kunalDear Kunal
This is the process i have defined for rework. let me know your feedback
1.Reject the material in QA32 to block stock
2.Reverse faulty material using Tcode MB1A u2013 262 movement type against the production order
3.if you need to scrap highly faulty materials use Tcode MB1A u2013 551 movement type against a cost centre
4.Create a rework order using Tcode Co01 order type (PP03)
5.Enter the Parent production order number in the goods receipt tab in Co01. (inbound delivery)
6.Issue goods against the rework order using MIGO
7.confirm the rework order through co11n
8.Move the material back from block to quality using Tcode MB1B u2013 349 movement type (activate 08 inspection)
9.Inspection lot created
10.Do the posting accordingly
Regards
Gajesh -
Making GL Account field editable during Approval Process
Hi Experts,
We are in SRM 7.0 and using process controlled workflow.
As a business requirent,we want the GL account field to be editable during the approval process i.e during approval process,approve wants to change the GL account in the shopping cart as the GL account may not be correctly entered.
Is it possible to make the GL account field editable during approval process?if Yes,please share how it can be done.
Any pointers will be highly appreciated.
Thanks & Regards,
RupeshHi,
You can find info in help.sap.com.
http://help.sap.com/saphelp_srm70/helpdata/EN/5c/b5a6783fc34466834fbc48def23d2d/frameset.htm
http://help.sap.com/saphelp_srm70/helpdata/EN/01/ad7bc4d66f4bc1a52a0cd21cdfa2ff/frameset.htm
Level Type: There are 3 possible entries. Approval with completion, Approval and Automatic. Within
a completion step the document can be changed by the approver if the u2018Changeableu2019 flag is set.
Within the approval phase, the document can only be approved or rejected but not changed. It is not
possible to mix the two phases of completion and approval. The completion phase is always before
the approval phase. The automatic step is a final means of validating the approval process, and to
verify that at least one step was returned without any error (example: event 0EV999). Depending on
the task ID assigned to the automatic step, the document will then be either approved or rejected.
Regards,
Masa -
CRM 2011+An error has occurred during report processing. (rsProcessingAborted)
Hi,
i have installed CRM 2011 on-premise version in Server A. Database and CRM 2011 Reporting Extenison in Server B. Both the server are 64 bit server and IIS 7.0 . i can able to browse the Report server url. USer as been added in Sql DB Logins and
as permission to Reportserver and ReportservertempDB.
i can able to access the CRM Reports only using Admin Credenttials that is from the credential which Report server is installed and configured
Error in server 1:
Web service request SetDataSourceCredentials to Report Server
(http://servername/Reportserver_XXXSQLSRVR)failed with SoapException. Error: An error has occurred during report processing. (rsProcessingAborted).
Error in Server 2: took this error From error log file
processing!ReportServer_0-1!7e4!03/16/2011-10:34:51:: e ERROR: Data source 'CRM': An error has occurred. Details: Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: Cannot create a connection to data source 'CRM'. ---> Microsoft.Crm.Reporting.DataExtensionShim.Common.ReportExecutionException:
Caller S-1-5-21-1587242514-2812063576-513219026-1110 has insufficient privilege to run report as user 9f69b98c-c73d-e011-bd85-842b2b6567dd
processing!ReportServer_0-1!7e4!03/16/2011-10:34:51:: e ERROR: An exception has occurred in data source 'CRM'. Details: Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: Cannot create a connection to data source 'CRM'. ---> Microsoft.Crm.Reporting.DataExtensionShim.Common.ReportExecutionException:
Caller S-1-5-21-1587242514-2812063576-513219026-1110 has insufficient privilege to run report as user 9f69b98c-c73d-e011-bd85-842b2b6567dd
processing!ReportServer_0-1!7e4!03/16/2011-10:34:51:: i INFO: DataPrefetch abort handler called for Report with ID=. Aborting data sources ...
processing!ReportServer_0-1!7e4!03/16/2011-10:34:51:: e ERROR: Throwing Microsoft.ReportingServices.ReportProcessing.ProcessingAbortedException: An error has occurred during report processing., ;
Info: Microsoft.ReportingServices.ReportProcessing.ProcessingAbortedException: An error has occurred during report processing. ---> Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: Cannot create a connection to data source 'CRM'.
---> Microsoft.Crm.Reporting.DataExtensionShim.Common.ReportExecutionException: Caller S-1-5-21-1587242514-2812063576-513219026-1110 has insufficient privilege to run report as user 9f69b98c-c73d-e011-bd85-842b2b6567dd
Eventvwr error in server 2:
Failed to unload app domain DefaultDomain. The following exception occurred: Error while unloading appdomain. (Exception from HRESULT: 0x80131015).
I tried the Following ways to fix it
1.added User as content manager
2.In CRM apppool i have Admin in identity column
its really paining when i'm unable to access the CRM 2011 Default Reports. got stucked for a day.
Thanks, Saraswathy KumaraveluHi All,
I encountered this same issue today after installing CRM 2011.
CRM 2011 on Server A
SQL and SSRS 2008 R2 on Server B
I found that I got the same errors described here when running the standard reports even after I had installed the Reporting Extension (CRM 2011 replacement for CRM 4.0 Data Connector). The reason I got the error was because the 'Data Source Type' had not
been updated in Report Manager.
Here's how I resolved:
1. Browse to Report Manager (http://SERVERB/Reports)
2. Open the Organisation_MSCRM folder
3. Click Show Details
4. Open the MSCRM_DataSource
5. Change the Data Source Type from Microsoft SQL Server
to Microsoft Dynamics CRM SQL
*Note: - This option is only available once Reporting Extension has been installed on SSRS Server.
6. Clear the contents of the Connection String box
7. Set the Connect Using: option to Credentials Supplied by user running the report
but do NOT check the
Use as Windows Credentials when connecting to the DataSource option.
8. Click Apply
9. Restart the SQL Reporting Services Service in
Reporting Services Configuration Manager
10. Test by running one of the Standard CRM Reports (e.g. User Summary)
Ta Da!! - Success!!
Hope this helps! -
Symptom:
When you view a report with SCCM, you may encounter the following error message:
An error has occurred during report processing.
Under the details box, you can see the detailed error information as below:
System.Web.Services.Protocols.SoapException: The report server has encountered a configuration error. Logon failed for the unattended
execution account. ---> Microsoft.ReportingServices.Diagnostics.Utilities.ServerConfigurationErrorException: The report server has encountered a configuration error. Logon failed for the unattended execution account. ---> Microsoft.ReportingServices.Diagnostics.Utilities.LogonFailedException:
Log on failed. Ensure the user name and password are correct. ---> System.ComponentModel.Win32Exception: The user name or password is incorrect
at Microsoft.ReportingServices.Library.ReportingService2005Impl.GetReportParameters(String Report, String HistoryID, Boolean ForRendering, ParameterValue[] Values, DataSourceCredentials[] Credentials, ParameterInfoCollection& Parameters)
at Microsoft.ReportingServices.WebServer.ReportingService2005.GetReportParameters(String Report, String HistoryID, Boolean ForRendering, ParameterValue[] Values, DataSourceCredentials[] Credentials, ReportParameter[]& Parameters)
Figure 1 is the screenshot of the error message in SCCM:
Figure 1.
Cause:
According to the detailed error message, it indicates that “The report server has encountered a configuration error. Logon failed for the unattended execution account.”
and “The user name or password is incorrect”, so this issue would be caused by the mismatched credential stored in report server.
Solution:
To solve this issue, you can follow the steps below:
1.
Access Report Manager URL on your reporting server.
From figure 2, you can see that the URL for Report Manager is
http://SCCM:80/Reports
in our lab environment. You can check your Report Manager URL in Reporting Services Configuration Manager.
Figure 2.
2.
Find out the date source {5C6358F2-4BB6-4a1b-A16E-8D96795D8602} and access it.
Figure 3.
3. Test connection (Figure 4)
You can have a test connection to check whether the credentials stored in the report server are correct or not.
Figure 4.
4.
Modify the password or choose another authentication method
If you want to change the password, please make sure that password is the same as the one that you have set for that user account in the domain.
5. Confirm connection
After you change the password, you can test connection again. From figure 5, we can see that connection created successfully.
Figure 5.
After all the steps above, there is no error message when viewing the report. (Figure 6)
Figure 6.
Please click to vote if the post helps you. This can be beneficial to other community members reading the thread.ok . the user name is sccm.admin this user have the assignment to run as a services, he is a domain admin, on the sql server this user have the sysadmin, i create the reporting with the Reporting Services Configuration Manager, and on the Database i use
the sccm.admin to create the new database, on the Service Account i use sccm.admin user, also this user have local administrator on the SCCM server, + i give him the dbreader on All the database on the SCCM server witch it also the SQL server, i add the sccm.admin
on the reporting web the system role and check the all settings give him full permissions
do i make my self clear ? (my English is not so bright )
now from the SCCM 2012 console , some reports run perfectly, and some run and trow this error at me
Microsoft.Reporting.WinForms.ReportServerException
An error has occurred during report processing. (rsProcessingAborted)
Stack Trace:
at Microsoft.Reporting.WinForms.ServerReport.ServerUrlRequest(Boolean isAbortable, String url, Stream outputStream, String& mimeType, String& fileNameExtension)
at Microsoft.Reporting.WinForms.ServerReport.InternalRender(Boolean isAbortable, String format, String deviceInfo, NameValueCollection urlAccessParameters, Stream reportStream, String& mimeType, String& fileNameExtension)
at Microsoft.Reporting.WinForms.AsyncMainStreamRenderingOperation.RenderServerReport(ServerReport report)
at Microsoft.Reporting.WinForms.AsyncRenderingOperation.PerformOperation()
at Microsoft.Reporting.WinForms.ReportViewer.AsyncReportOperationWrapper.PerformOperation()
at Microsoft.Reporting.WinForms.ProcessingThread.ProcessThreadMain(Object arg)
this poor gay have the same problem
An error has occurred during report processing. (rsProcessingAborted) -
Looking for quick creation of a new contact during activity processing
We are looking for a quick way to create a new contact during the process of activity management. Once I have selected my business partner and then I search for a contact, if the contact I need does not exist yet there are several long involved ways to go create the new contact. Several people from SAP have alluded that there is an add button that should be available on the business partner central search window that comes up when you look for contacts but we have no add button. Does someone know if the add button becomes available later? We are on CRM 5.0 - has anyone customized a way to add a contact here without having to go into the account application relationship tab. We are coming off of Mobile Sales where there is a pop up window to add a contact. We need to replace this functionality.
Hello Pascale,
"Follow-up" button is present to enable a quick creation of follow up.
That is end user can just input those limited fields, and click on this button to create the document without going into the detail.
And at the same time, standard IC do provides another link to the detailed follow up documents to enable user add more detail.
The link "Follow-up Details" can realize such purpose and should be the one you are asking for.
The steps are:
- select the transaction type in the drop down;
- click on "Follow-up Details" link, this lead to another page of the detailed activity creating, only at this time the activity is being created;
- click on the Back button without save, you will return to the previous screen, and get the link in Activity Clipboard for future access;
Hope I have understood your requirement correctly!
Hongyan -
HI..
I'm having an issue while installing obiee 11g(11.1.1.7.0) in windows server 2012 and using the database as ms sql server 2008. During configuration process after the installation process is completed , here the process is stopped at "Step:executing opmnctl start configuration_obisch1" status "failed"
Here is the error:
Error
opmnctl task failed
Step Executing: opmnctl start coreapplication_obisch1 failed
Configuration Action "Executing opmnctl start coreapplication_obisch1 " has failed. please check log files...
any help would be great
thanks..Friend,
Installer file size is:
Size: *1.23 GB (1,323,085,837 bytes).*
Size on disk: *1.23 GB (1,323,089,920 bytes).*
I tested also disabling antivirus on my PC and disconnect the power cord before starting the installation of JDeveloper. In both tests the result was the same.
Some additional recommendations to solve this case.
Thank you for supporting.
Edited by: Luis_vkacito on Nov 15, 2012 6:48 AM -
when I installed iTunes 10.6 to windows 7, during the process i got this message -" There is a problem with this windows installer package. A program required for this install to complete could not be run" and after that the setup closed automatically. Plaese tell me if any setting up of windows is in order.
Try looking at the two previous discussions listed on the right side of this page with your same question.
Also, try searching/posting in the iTunes forum since you do not have an iPod problem. -
HELP PLS.......when i download iTunes during downloading process on messege shown: "An error occurred during the installation of assembly‘Microsoft CRT.version=”8.0.50727.6195 publicKey Token = 1f c8 b3 b9a 1e 18e 3b processo rArhitecture = x86." please refer to Help and Support for more information. HRESULT: 0x80073712.
when click ok it rolling back and start process download again. and at last this messege appear: Service‘Apple Mobile Device’ (Apple Mobile Device) failed to start. Verify that youhave sufficient privileges to start system services with option
Abort Retry Ignore
i tried all option one by one but i did not success to download itunes.
Please help .You should check Windows update for Service Pack update, if there is any.
Otherwise, try to fix and update windows system filesas follows:
Go to command prompt (START/ALL PROGRAMS/ACCESSORIES right mouse click "command prompt" and choose "Run as Administrator"
type in
sfc /scannow
let Windows fix any system files that need to be repaired.
Restart the computer if it did actually repair any files.
Then do the download again.
Maybe you are looking for
-
HT1688 how can i figure out a passcode on my cellphone?
how can i figure out a passcode that was put on my phone, person locked me out of my phone
-
No Podcast Image :(
I know there are several other posts regarding no image showing in the iTunes listing etc... I, too, have the same problem even AFTER editing, changing, updating, pinging for about 6-7 days now. It most likely is something I'm not doing correctly. No
-
Sapinst segfault with coredump :X
Hei, I want install SAP on Solaris IA 64. I have already install with success Oracle but i have a problem with sapinst ; I have read more and more installation guide and i have check the system with : memlimits -l 20000 [OK] export LD_LIBRARY_PATH=/
-
Using Ipod between work and home computers
I recently got an Ipod and a new laptop. I synced it with my computer at work to put all the music on the Ipod, and now I'd like to set up my Ipod on my new home computer. When I open ITunes, it says something about resetting the ipod to use this lib
-
MacBook Pro, 5.1 audio issue!
Hello Apple community! At first, I searched many threads here and on other forums, also youtube and haven't found answer to my problem. I am trying to set my 5.1 speakers via external sound card. I have found nice topic here by Vegas, who shows how t