Hi,
I'm totally new to Softmotion. So my questions might be very naive.
Anyway, we are currently using a Deltatau motion controller with three motor drives. The drives are all linear type and the motion controller provides the commutation. The motion controller is kind of expensive, a few $k. So I'm thinking, if it is possible to use a small embedded PC for a few $$$ and load it with the Softmotion software and control the drives.
So a few questions:
1) Can the Softmotion perform decoding if I connect the A/B encoder signal to the digital I/O of the embedded PC?
2) Can the Softmotion perform commutation and output the A/B signals with DAC?
3) I assume connecting the limit switches to the I/O should be no problem for the Softmotion to pickup.
4) What is the cost of the Softmotion per copy?
Anyway, those are my questions today. Is there anybody who might have done it this wya before?
Thanks,
Jay

Hi Jay,
Take a look at this tutorial for acquiring a basic knowledge of what the software can do, but more important, what hardware setup you need to do this tasks.
There are several approaches (CompactRIO, PCI, PXI) but fundamentally NI handles 3 types of signals (CCW, CW which are Direction & step. Plus a drive enable) that we use for controlling motor drives. If your drive accepts these signals we could say you could potentially use NI products to interface with it.
I encourage you to talk to one of our local sales engineers for more information.
Alejandro | Academic Program Engineer | National Instruments

Similar Messages

  • Where is the output for PWM on NI 7774 connected to motion control card 7356

    Hi,
    I have NI motion control card 7356 which interfaced through 7774 interface board. PWM outputs are written to be on pins 5 and 9 on Digital IO, yet there is no indication about the whereabouts of these PWMs on the interface board (7774). Would you please help???
    Asst. Prof. Vasfi Emre Omurlu, Ph.D.

    Simitci,
    For the digital I/Os a UMI-7774 provides access to 16 digital lines. If you want to access other signals of the digital connector, you shouldn't connect it to the UMI but to another breakout box like the SCB-68. Please note that compared to the UMI-7774 the SCB-68 doesn't provide optical isolation or 24 V connectivity. If this doesn't work for you, you could think of building a customized cable that connects the lines for the16 digital I/Os to the UMI and the rest of the signals to another connector or breakout box.
    You also should be aware of the fact that the PWM outputs of 73xx boards are static. That means that you can change the duty cycle and output frequency of these signals in software only, which is quite slow. In most cases these PWM signals can't be used for motion control tasks.
    What do you intend to do with the PWM signals?
    Thanks and kind regards,
    Jochen Klier
    National Instruments

  • Can I replace my original LED control card to inverter card in T500

    I bought my T500 half years ago.  It is WXGA 1280*800 with LED backlight.  However, I want to upgrade the screen to WSXGA+, which is 1680*1080, unfortunately, the WSXGA+ works with inverter card.  My question is , can I replace my original LED control card by inverter card?
    part number of those 2 are
    LED control:  42W8080/ 42W8081 /42W802 ( I do not remember the exact same )
    Inverter card: 41W1338
    Thanks
    Sean 

    Welcome to the forum!
    The answer to your question is "no".
    Cheers,
    George
    In daily use: R60F, R500F, T61, T410
    Collecting dust: T60
    Enjoying retirement: A31p, T42p,
    Non-ThinkPads: Panasonic CF-31 & CF-52, HP 8760W
    Starting Thursday, 08/14/2014 I'll be away from the forums until further notice. Please do NOT send private messages since I won't be able to read them. Thank you.

  • Replacing my Intel 5100 AGN card with a Intel 2200 (X200 Thinkpad)

    Hi there,
    Does anyone knows if this will work ? 
    I'm planning to change the 5100 AGN card with an old Intel 2200 model because I want to play with OSX86 on my X200.
    -- Shay

    Answer should be available here http://www.insanelymac.com/forum/index.php?showforum=152

  • Has anybody used motion control card like a CNC contol with G-codes with part program editor?

    I have to use national instruments PXI 7344 motion card to substitute a CNC control that uses G-codes and M-codes in a part program . I need to know if some body has already developed such an application and also developed a part program editor.

    ABMSoft - an NI alliance member in Eastern Europe has developed a very powerful G-code interpretor for LabVIEW. Their ABMS-NC toolkit for LabVIEW also includes an offline simulation tool. They have successfully deployed many machines using this toolkit. Its available directly from ABMSoft for $995. You can contact ABMSoft directly.
    More info on ABMSoft (Contact info and product details)
    http://sine.ni.com/apps/we/niaa.com_view?p_all_id=7974
    Documentation on ABMSoft's website
    http://www.abmsoft.com/NI-NC.pdf
    Thanks,
    Rahul
    Rahul Kulkarni
    National Instruments

  • Motion:  Video Cards with Mac Pro?

    I don't see the new video cards for the Mac Pro listed in the "minimum" or "recomended" system requirements.
    Does anyone know how these new cards will rate?

    My understanding is that the X1900 is pretty powerful, the 7300 - not so much - more like the 6600, and of course the Quadro is smokin' - but probably not good bang-for-buck when it comes to Motion. Meaning that the Quadro will give great results, but not a LOT over the X1900...
    Of course, the x1900 still has the 2k texture limit. And it's too early for any aftermarket/flashing options yet.
    Patrick

  • How to use ELMO motion control device with LABVIEW

    Hi,
    I am
    new to LabVIEW withvery little controls
    experience (just now graduated).  I need to use LabVIEW, NI USB 6009( DAQ)
    and a Harmonica servo drive from Elmo to control a voice coil.  . What I
    am looking for is some general guidance to get me started; point me in
    the correct direction so I can get rolling.  I will be using a RS-232
    line between the Harmonica and the PC.
    I have generated a sine waveform to the NI USB 6009 from LABVIEW. I have to send this signal through the ELMO Harmonica 5/60 N to control a voice coil. I have
    been reading the Elmo SimpleIQ Software Manual and am  lost Kindly help me out. 
    Regards,
    Pawan 
    The software manual states using Interpreter Language or User
    Programming Language.  Both of the languages seem to resemble what I
    remember of C++, sort of.  The document explains "while" and "for"
    loops, etc.; however, my understanding is that I should be able to use
    LabVIEW to accomplish such tasks and then just ask LabVIEW to output a
    command to the Bassoon to control my voice coil.  My best guess is that
    I use the "System Commands" to output commands to the Bassoon although
    the software manual also mentions compiling code similar to that of
    standard programming modes.
    Please help me out.
    Thanks        

    Continued here.
    LabVIEW Champion . Do more with less code and in less time .

  • I am using 7340 motion control card. what i am doing is ,first of all i initialise my 7340 card by MAX and then through motion assistant i am making a 1-d motion for my steeper motor using drive MID-7604/7602.

    then i generate the labview code from there,,,,,,,,what is happening in labview is i am able to run the motor but to stop the motor by using stop button there or by using a while to stop the motor...it is not responding i have to go back to motion assistant to stop the motor...............can any body suggest me what to do ,,,is there any problem in my softwares settings..................???????
    Message Edited by 0518 on 02-17-2009 01:39 AM

    Hello,
    You have mentioned that you are using motion assistant to generate the code. Do you run the LabVIEW VI that it has generated or are you directly running it from Motion assistant? 

  • PWM in Motion Control

    HI All,
    I am facing a problem in Motion Controller.
    We are using PCI 7344 and UMI 7774.
    Now their is a connector on the Motion control card for Digital I/O.
    In this Pin No 5 and Pin No9 are PWM1 and PWM2 respectively.Now I have used to VI PWm duty and config PWM. I am seeing the PWM waveform on CRO.But to my surprise the output is not matching the required data.
    IF you go for HElp and click config PWM VI block , you can see a table given where the internal clock selected corresponds to a particular frequency in 734X and 735X.Now since I am using 7344 my frequency should match with 734X table , whereas this is not happening and
    my frequency matches the table of 735X.
    SO i am bit confused about the controller specs or is someor the other way Iam missing some thing more.
    Regards
    Manish Karnik
    Cruiser Controls
    Mumbai.

    Manish,
    please have a look at this table which comes with the NI Motion function help file for NI-Motion 7.2. This table should contain the correct values. The latest revisions of the 734x are named 7340 and the PWM output should follow this table.
    Best regards,
    Jochen Klier
    National Instruments Germany
    Message Edited by Jochen on 07-05-2006 01:34 PM
    Attachments:
    PWM table.jpg ‏233 KB

  • PXI ethernet activation requires initializing motion control?

    On a PXI with multiple 7344 motion control cards and an ethernet LAN connection, ethernet does not become active (e.g., flickering LED on the PXI controller connector) until the 7344 card is initialized. Shouldn't ethernet become active as part of booting up?

    The behavior is no longer reproducible, although several combinations of booting and plugging in the Ethernet cable were explored. LAN access is now available promptly upon booting or connecting the cable, as expected. A residual explanation might be that Win2K on the PXI 8175 controller did not fully respond when DHCP on the local router/firewall changed the PXI's IP address, due to changes in the network configuration. In this case, initializing the 7344 cards is taken as an event that caused the OS to complete LAN activation. Many other events with other hardware might have had the same effect.

  • 4 channel independen​t motion controll adressing

    I want to run four indepent motion/plc programs with each system using one axis and one analog output as a channel of the same motion controll card (PCI 7344)
    Each indepentent system has its own bottons for starting different setions of a semi automated process and these processes are intependent in timing.
    Can this be done with one 4 axis PCI 7344 NI motion card?

    The answer is short and simple: yes.
    You only need to make sure that the controller is initialized before
    you start your four applications and that you don't share resources
    between the programs.
    Best regards,
    Jochen Klier
    National Instruments Germany

  • Download for 7342 motion control

    Are there any downloads avaliable to control an xy stage using Labview 6.1 and a PCI-7342 motion control card?

    Two Axis Vector Move with Position Monitor.vi located in the Multiple Axis.llb ('default LabVIEW path'\Examples\Motion\FlexMotion\) demonstrates two-axis motion and should work with the PCI-7342. That example demonstrates the fundamentals of two-axis vector move but if you need a more specific example let me know.
    Yusuf C.
    Applications Engineering
    National Instruments

  • How can I use flex motion control VI without hardware?

    I would like to try and simulate the motion control of my system before i hook up the motion control card. But when I use the VI in flex motion contro took kit it asks for address or something and gives me an error. Can't I just simulate without hardware?

    Hello,
    The only way you can use FlexMotion without any hardware is to set it up as Open Loop Stepper Control. Otherwise, you will get errors when no encoder signal is fed back to the controller.
    Please let me know if you have any further questions.
    Regards,
    Andy Bell
    Application Engineer
    National Instruments

  • Error -10401 appears when I try to read in my Encoders (TTL-Signa​l) via a LabView-"n​uDrive 2SX-411" and Motion Controller Card

    Hy there.
    Im using two "Haidenhain ERN 420" Encoders with TTL-Output Signal
    A NI-Motion Controller 7334 with an NI-"nuDrive 2SX-411"
    When I try to Read the Encoders Position (with ex.-Programm/Source) the Message: "Error -10401 occurred at AI Group Config ... the specified device is not a NI-product" appears
    Can anybody help me to initiallize/Use the Encoders in Labview 6.01?
    thanks, phil.

    Phil,
    It looks to me according to the error that you were trying to use DAQ functions to access the Motion controller. The Motion controller uses its own functions. There are two for reading position:
    Functions Palette >> Motion & Vision >> Flexmotion >> Trajectory Control >> Read Position.
    Functions Palette >> Motion & Vision >> Flexmotion >> Analog & Digital I/O >> Read Encoder Position.
    You may find a useful example in:
    C:\Program Files\National Instruments\LabVIEW 6.1\examples\Motion\FlexMotion\One Axis.llb\One Axis Move with Position Monitor.vi
    Make sure that you have configured and initialized your board properly in MAX.
    I would suggest that you post your question on the Motion Control section and not in the LabVIEW section. Also, check the Dev
    elopment Library section of the NI Developer Zone for the Motion Control section with tutorials and example code.
    Good luck!
    Nestor.
    Nestor
    National Instruments

  • Wanted Computer Controled Electronic Cards with Software for Motion Control

    Hi everybody
    Already worked on designing a cnc table to cut sheet materials.
    But we don't know enough for electronics. We think a system which is
    software driven from pc. So, we look for Wanted Computer Controled
    Electronic Cards with Software for Motion Control but we don't know more
    which motors, electronic cards and control panel we have to use.
    Please help me. Thanks.
    Atilla KESKEKLER
    Ahmet Bayman Cad. No 10/4 Otosanayi 4.Levent 80650 Istanbul Turkiye
    Tel: + 90 212 270 74 00 Fax: + 90 212 270 75 89
    www.aareklam.com.tr [email protected]

    Dear Atilla,
    You should contact AutomationSolutions (www.AutomationSolutions.com) to receive help with designing your system. They can spec your motors and help you picking the correct controllers and drivers from National Instruments to control the motors that you want to use. Please let me know if you need more information about the capabilities of Motion Control systems from National Instruments.
    Thank You,
    Morten Jensen
    National Instruments

Maybe you are looking for

  • Two items same colour swatch; showing differently!

    I am constantly having this problem so I thought I'd ask for a bit of guidance. I have a colour swatch that I use regularly, and I use it for table headers a lot. For some reason on the same page, using the same swatch the table headers look differen

  • My flash player doesnt display text

    so every time i goto youtube.com or listen.grooveshark.com, theres text it the flash player thats suppost to show up, for like the names of videos or music. but its not there any reason why, and how do i fix it...? i use google chrome but i've found

  • Wants me to sign in, I already have

    I have opened Adobe Download Assistant and am logged in as it says up the top right "Welcome, xxxxx" However at the bottom I am trying to download Premiere CS6 and it says below the download bar "Please sign in with you Adobe ID to continue." Am I no

  • Need speedily response

    Upgraded my bbm messenger and after doing so the set up would not go through, please respond as soon as possible so as to advise me what to do as i am in dire need. After you've helped you can add me on bbm Removed personal information to comply with

  • Where is the "core" folder?

    I'm using Mac OS X 10.7.4 Server and I'm looking for the core folder to get a core dump. It's not in the root directory. Where is this core folder? Regards, Oliver