Restricting Coherence traffic to a single NIC in a box with 2 NICs

Hi All,
I have a new question, or rather a request for confirmation / correction.
Am I right, that for restricting Coherence traffic to a dedicated network card and segment, I need to do the following things:
1. Set up a route entry in the routing table directing the multicast address to the particular network interface, e.g. (syntax might not be correct, assume 225.1.1.1 to be the clusteraddress and eth1 the dedicated network interface).:
route add 225.1.1.1/32 eth12. Set tangosol.coherence.localhost to the ip address of eth1 within the same machine. (different setting on each box).
Do I need to do anything else?
Thanks and best regards,
Robert

Hi Cameron,
it seems, we needed to add the route for the multicast IP on Linux to be directed to the Gigabit network interface, after all. Without that, the cluster heartbeat was noticed, but the Linux box was not able to join the cluster of HP-UX boxes.
We are also receiving this warning, but I don't think it has anything to do with the connection problem:
2006-11-13 12:38:02.154 Tangosol Coherence 3.2/357 (Pre-release) <Warning> (thread=main, member=n/a): UnicastUdpSocket failed to set receive buffer size to 1428 packets (2096304 bytes); actual size is 89 packets (131071 bytes). Consult your OS documentation regarding increasing the maximum socket buffer size. Proceeding with the actual value may cause sub-optimal performance.
Best regards,
Robert

Similar Messages

  • "Dynamic List Box with Single Selection" Survey Suite in CRM 6.0

    Hi
    I am using CRM 6.0. There in Survey Suite there are 2 answering options "Dynamic List Box with Single Selection" & "Dynamic List Box with Multiple Selection". I am able to make out, how we can assign values to this. I have seen example "Example_Dynamic_survey" also.
    I believe we have to use programming for populating this. But how do we have to carry that out.
    Thanx and Regards
    Hitesh

    Hi Hitesh,
    There is no need of programming for populating values for Answer category 'List Box with Single Selection' or 'List Box with Multiple Selection'. You have to follow the following steps to populate values for those:
    - In the Answer Category select List Box with Single Selection from drop down list
    - Then on left hand side tree, right click on Answer and select Insert Answer Option (Answer->Insert Answer Option)
    - Then on right side, provide Text for the answer (value)
    - To add more values, repeat the process Answer->Insert Answer Option and providing text for those answers in the right side.
    Similarly you can populate values for 'List Box with Multiple Selection' also.
    This has to be done in the transaction CRM_SURVEY_SUITE.
    Hope this is clear to you
    regards
    Srikantan

  • How to Restrict Single Delivery Date for PO with Multiple Line Items

    Dear Experts,
    How to Restrict Single Delivery Date for PO with Multiple Line Items.
    System needs to through Error Message if User Inputs Different Delivery Dates for PO with Multiple Line Items in ME21N Tcode.
    Can we achive this by Some Enhancement in SAP or Not ???
    If so how to do it.
    Any Inputs is highly appreciated.
    Thanks and Regards,
    Selvakumar. M

    Hi Selvakumar,
    we can resrict the PO to have a single delivery date in all the line items by means of giving a error message or overwiting the delivery date keyed/determined in the line item.
    You can use the BADI -> ME_PROCESS_PO_CUST. In which you need to implement the method PROCESS_SCHEDULE.
    (for technical aid - This method will be called for each and every PO line item, From the imporing parameter im_schedule we can get all the details of current PO line, even we can change the data in the current PO line. )
    Regards,
    Madhu.

  • Can you restrict APEX users to a single browser session?

    I'm using APEX3.2.1
    Is there a package,function, view or table in APEX that can be checked to see if a user_id
    already has an active session (one that hasn't been purged yet).
    I wish to restrict each user to a single active browser session.
    Cheers
    dfrost

    Hi Roel
    I've had a look at the views and it looks to be exactly what I'm after thanks very much for your help.
    I've only been working on APEX a short while the info on the forum and all the expert blogs are of huge help.
    Thanks
    Derek
    Australia

  • RDS 2012 R2 - Allow Some Users Multiple Logon Sessions and Restrict Other Users to a Single Session

    In Server 2012 R2 RDS, is there a way to allow some users to log on multiple times, but restrict other users to a single logon? On an OU or AD group basis?
    I know there is a GPO setting under Computer Configuration for restricting users to a single logon, but this does not allow me to differentiate on a user basis (only on a per server basis).
    Thanks,
    James

    Hi James,
    From my perspective and knowledge, sorry to say but there is no such option\way to provide this permission at same time. If a user specifies a different program to start when the user connects to the RD Session Host server, a new session will be created on
    the RD Session Host server for the user, even if the RD Session Host server is configured to restrict users to a single session. A user can specify a program to start on connection on the Programs tab under Options in Remote Desktop Connection.
    Hope it helps!
    Thanks.
    Dharmesh Solanki
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • VMQ issues with NIC Teaming

    Hi All
    Apologies if this is a long one but I thought the more information I can provide the better.
    We have recently designed and built a new Hyper-V environment for a client, utilising Windows Server R2 / System Centre 2012 R2 however since putting it into production, we are now seeing problems with Virtual Machine Queues. These manifest themselves as
    either very high latency inside virtual machines (we’re talking 200 – 400 mSec round trip times), packet loss or complete connectivity loss for VMs. Not all VMs are affected however the problem does manifest itself on all hosts. I am aware of these issues
    having cropped up in the past with Broadcom NICs.
    I'll give you a little bit of background into the problem...
    Frist, the environment is based entirely on Dell hardware (Equallogic Storage, PowerConnect Switching and PE R720 VM Hosts). this environment was based on Server 2012 and a decision was taken to bring this up to speed to R2. This was due to a number
    of quite compelling reasons, mainly surrounding reliability. The core virtualisation infrastructure consists of four VM hosts in a Hyper-V Cluster.
    Prior to the redesign, each VM host had 12 NICs installed:
    Quad port on-board Broadcom 5720 daughter card: Two NICs assigned to a host management team whilst the other two NICs in the same adapter formed a Live Migration / Cluster heartbeat team, to which a VM switch was connected with two vNICs exposed to the
    management OS. Latest drivers and firmware installed. The Converged Fabric team here was configured in LACP Address Hash (Min Queues mode), each NIC having the same two processor cores assigned. The management team is identically configured.
    Two additional Intel i350 quad port NICs: 4 NICs teamed for the production VM Switch uplink and 4 for iSCSI MPIO. Latest drivers and firmware. The VM Switch team spans both physical NICs to provide some level of NIC level fault tolerance, whilst the remaining
    4 NICs for ISCSI MPIO are also balanced across the two NICs for the same reasons.
    The initial driver for upgrading was that we were once again seeing issues with VMQ in the old design with the converged fabric design. The two vNics in the management OS for each of these networks were tagged to specific VLANs (that were obviously accessible
    to the same designated NICs in each of the VM hosts).
    In this setup, a similar issue was being experienced to our present issue. Once again, the Converged Fabric vNICs in the Host OS would on occasion, either lose connectivity or exhibit very high round trip times and packet loss. This seemed to correlate with
    a significant increase in bandwidth through the converged fabric, such as when initiating a Live Migration and would then affect both vNICS connectivity. This would cause packet loss / connectivity loss for both the Live Migration and Cluster Heartbeat vNICs
    which in turn would trigger all sorts of horrid goings on in the cluster. If we disabled VMQ on the physical adapters and the team multiplex adapter, the problem went away. Obviously disabling VMQ is something that we really don’t want to resort to.
    So…. The decision to refresh the environment with 2012 R2 across the board (which was also driven by other factors and not just this issue alone) was accelerated.
    In the new environment, we replaced the Quad Port Broadcom 5720 Daughter Cards in the hosts with new Intel i350 QP Daughter cards to keep the NICs identical across the board. The Cluster heartbeat / Live Migration networks now use an SMB Multichannel configuration,
    utilising the same two NICs as in the old design in two isolated untagged port VLANs. This part of the re-design is now working very well (Live Migrations now complete much faster I hasten to add!!)
    However…. The same VMQ issues that we witnessed previously have now arisen on the production VM Switch which is used to uplink the virtual machines on each host to the outside world.
    The Production VM Switch is configured as follows:
    Same configuration as the original infrastructure: 4 Intel 1GbE i350 NICs, two of which are in one physical quad port NIC, whilst the other two are in an identical NIC, directly below it. The remaining 2 ports from each card function as iSCSI MPIO
    interfaces to the SAN. We did this to try and achieve NIC level fault tolerance. The latest Firmware and Drivers have been installed for all hardware (including the NICs) fresh from the latest Dell Server Updates DVD (V14.10).
    In each host, the above 4 VM Switch NICs are formed into a Switch independent, Dynamic team (Sum of Queues mode), each physical NIC has
    RSS disabled and VMQ enabled and the Team Multiplex adapter also has RSS disabled an VMQ enabled. Secondly, each NIC is configured to use a single processor core for VMQ. As this is a Sum of Queues team, cores do not overlap
    and as the host processors have Hyper Threading enabled, only cores (not logical execution units) are assigned to RSS or VMQ. The configuration of the VM Switch NICs looks as follows when running Get-NetAdapterVMQ on the hosts:
    Name                           InterfaceDescription             
    Enabled BaseVmqProcessor MaxProcessors NumberOfReceive
    Queues
    VM_SWITCH_ETH01                Intel(R) Gigabit 4P I350-t A...#8 True    0:10             1            
    7
    VM_SWITCH_ETH03                Intel(R) Gigabit 4P I350-t A...#7 True    0:14             1            
    7
    VM_SWITCH_ETH02                Intel(R) Gigabit 4P I350-t Ada... True    0:12             1            
    7
    VM_SWITCH_ETH04                Intel(R) Gigabit 4P I350-t A...#2 True    0:16             1            
    7
    Production VM Switch           Microsoft Network Adapter Mult... True    0:0                           
    28
    Load is hardly an issue on these NICs and a single core seems to have sufficed in the old design, so this was carried forward into the new.
    The loss of connectivity / high latency (200 – 400 mSec as before) only seems to arise when a VM is moved via Live Migration from host to host. If I setup a constant ping to a test candidate VM and move it to another host, I get about 5 dropped pings
    at the point where the remaining memory pages / CPU state are transferred, followed by an dramatic increase in latency once the VM is up and running on the destination host. It seems as though the destination host is struggling to allocate the VM NIC to a
    queue. I can then move the VM back and forth between hosts and the problem may or may not occur again. It is very intermittent. There is always a lengthy pause in VM network connectivity during the live migration process however, longer than I have seen in
    the past (usually only a ping or two are lost, however we are now seeing 5 or more before VM Nework connectivity is restored on the destination host, this being enough to cause a disruption to the workload).
    If we disable VMQ entirely on the VM NICs and VM Switch Team Multiplex adapter on one of the hosts as a test, things behave as expected. A migration completes within the time of a standard TCP timeout.
    VMQ looks to be working, as if I run Get-NetAdapterVMQQueue on one of the hosts, I can see that Queues are being allocated to VM NICs accordingly. I can also see that VM NICs are appearing in Hyper-V manager with “VMQ Active”.
    It goes without saying that we really don’t want to disable VMQ, however given the nature of our clients business, we really cannot afford for these issues to crop up. If I can’t find a resolution here, I will be left with no choice as ironically, we see
    less issues with VMQ disabled compared to it being enabled.
    I hope this is enough information to go on and if you need any more, please do let me know. Any help here would be most appreciated.
    I have gone over the configuration again and again and everything appears to have been configured correctly, however I am struggling with this one.
    Many thanks
    Matt

    Hi Gleb
    I can't seem to attach any images / links until my account has been verified.
    There are a couple of entries in the ndisplatform/Operational log.
    Event ID 7- Querying for OID 4194369794 on TeamNic {C67CA7BE-0B53-4C93-86C4-1716808B2C96} failed. OidBuffer is  failed.  Status = -1073676266
    And
    Event ID 6 - Forwarding of OID 66083 from TeamNic {C67CA7BE-0B53-4C93-86C4-1716808B2C96} due to Member NDISIMPLATFORM\Parameters\Adapters\{A5FDE445-483E-45BB-A3F9-D46DDB0D1749} failed.  Status = -1073741670
    And
    Forwarding of OID 66083 from TeamNic {C67CA7BE-0B53-4C93-86C4-1716808B2C96} due to Member NDISIMPLATFORM\Parameters\Adapters\{207AA8D0-77B3-4129-9301-08D7DBF8540E} failed.  Status = -1073741670
    It would appear as though the two GUIDS in the second and third events correlate with two of the NICs in the VM Switch team (the affected team).
    Under MSLBFO Provider/Operational, there are also quite a few of the following errors:
    Event ID 8 - Failing NBL send on TeamNic 0xffffe00129b79010
    How can I find out what tNIC correlates with "0xffffe00129b79010"
    Without the use of the nice little table that I put together (that I can't upload), the NICs and Teams are configured as follows:
    Production VM Switch Team (x4 Interfaces) - Intel i350 Quad Port NICs. As above, the team itself is balanced across physical cards (two ports from each card). External SCVMM Logical Switch is uplinked to this team. Serves
    as the main VM Switch for all Production Virtual machines. Team Mode is Switch Independent / Dynamic (Sum of Queues). RSS is disabled on all of the physical NICs in this team as well as the Multiplex adapter itself. VMQ configuration is as follows:
    Interface Name          -      BaseVMQProc          -        MaxProcs         
    -      VMQ / RSS
    VM_SWITCH_ETH01                  10                             
         1                           VMQ
    VM_SWITCH_ETH02                  12                              
        1                           VMQ
    VM_SWITCH_ETH03                  14                               
       1                           VMQ
    VM_SWITCH_ETH04                  16                              
        1                           VMQ
    SMB Fabric (x2 Interfaces) - Intel i350 Quad Port on-board daughter card. As above, these two NICs are in separate, VLAN isolated subnets that provide SMB Multichannel transport for Live Migration traffic and CSV Redirect / Cluster
    Heartbeat data. These NICs are not teamed. VMQ is disabled on both of these NICs. Here is the RSS configuration for these interfaces that we have implemented:
    Interface Name          -      BaseVMQProc          -        MaxProcs       
      -      VMQ / RSS
    SMB_FABRIC_ETH01                18                                   2                           
    RSS
    SMB_FABRIC_ETH02                18                                   2                           
    RSS
    ISCSI SAN (x4 Interfaces) - Intel i350 Quad Port NICs. Once again, no teaming is required here as these serve as our ISCSI SAN interfaces (MPIO enabled) to the hosts. These four interfaces are balanced across two physical cards as per
    the VM Switch team above. No VMQ on these NICS, however RSS is enabled as follows:
    Interface Name          -      BaseVMQProc         -         MaxProcs      
       -        VMQ / RSS
    ISCSI_SAN_ETH01                    2                                    2                           
    RSS
    ISCSI_SAN_ETH02                    6                                    2                           
    RSS
    ISCSI_SAN_ETH03                    2                                   
    2                            RSS
    ISCSI_SAN_ETH04                    6                                   
    2                            RSS
    Management Team (x2 Interfaces) - The second two interfaces of the Intel i350 Quad Port on-board daughter card. Serves as the Management uplink to the host. As there are some management workloads hosted in this
    cluster, a VM Switch is connected to this team, hence a vNIC is exposed to the Host OS in order to manage the Parent Partition. Teaming mode is Switch Independent / Address Hash (Min Queues). As there is a VM Switch connected to this team, the NICs
    are configured for VMQ, thus RSS has been disabled:
    Interface Name        -         BaseVMQProc        -          MaxProcs       
    -         VMQ / RSS
    MAN_SWITCH_ETH01                 22                                  1                          
    VMQ
    MAN_SWITCH_ETH02                 22                                  1                           VMQ
    We are limited as to the number of physical cores that we can allocate to VMQ and RSS so where possible, we have tried balance NICs over all available cores where practical.
    Hope this helps.
    Any more info required, please ask.
    Kind Regards
    Matt

  • Use a single variable value to compare with 2 characteristics

    Hi guys
        I need some advice on how to use a single variable value to compare with 2 characteristics in a Infocube.
    eg : I hv 2 characteristics in Infocube
           Launch date  &  Closing Date
       Now I want to display report where the variable date (inputted by user) is equal to Launch Date and Closing Date.
        with regards

    Bobby,
    if I right understood your situation, you have an input variable ZINPUT (related to a date 'A') and 2 others dates (yours Launch and Closing dates, 'B' and 'C').
    You want to display only the rows where A(user input)=B=C.
    Now you have to create 2 new variables (called ZB and ZC, related to B and C dates) NOT marked as 'ready for input' and set to 'mandatory variable entry'.
    Call Transaction CMOD for the definition of the customer exit (if not already existing!).
    Create a new project, maintain the short text, and assign a development class.
    Goto Enhancements Assignments and assign RSR00001. Press the button components to continue.
    Double-click on EXIT_SAPLRRS0_001. For documentation place the cursor on RSR00001 and use the menu Goto -> Display documentation. 
    Then double-click on ZXRSRU01. If the include doesn’t exist you have to create it; assign a development class and a transport request.
    Enter the coding:
    DATA: L_S_RANGE TYPE RSR_S_RANGESID.
    DATA: LOC_VAR_RANGE LIKE RRRANGEEXIT.
    CASE I_VNAM.
    WHEN 'ZB'.
    (and you have to repeate the same code also for the variable 'ZC' !)
    IF I_STEP = 2.
    READ TABLE I_T_VAR_RANGE INTO LOC_VAR_RANGE
    WITH KEY vnam = 'ZINPUT'.
    if sy-subrc = 0.
    L_S_RANGE-LOW  = LOC_VAR_RANGE-LOW.
    endif.
    L_S_RANGE-sign = 'I'.
    L_S_RANGE-opt = 'EQ'.
    append L_S_RANGE to e_t_range.
    ENDIF.
    ENDCASE.
    Save and activate the coding and the project.
    Now go to your query and use these two new variables to restrict B and C....et voilà !!!
    Let me know if you need more help (and please assign points !!! be generous !!!)
    Bye,
    Roberto

  • SR-IOV Uplink Port with NIC Teaming

    Hello,
    I'm trying to setup my uplink port profile and logical switch with NIC Teaming and SR-IOV support. In Hyper-V this was easy, just had to create the NIC Team (which I configured as Dynamic & LACP) then check the box on the virtual switch.
    I'm VMM it does not seem to like to enable NIC Teams with SR-IOV:
    Can anyone advise? I'm not using any virtual ports. I just want all my VMs to connect to the physical switch though the LACP NIC Team, something which I thought would be simple.
    I have a plan B - don't use Microsoft's NIC Teaming and instead use the Intel technology to present all the adapters as one to the host. I'd rather no do this.
    Thanks
    MrGoodBytes

    Hi Sir,
    "SR-IOV does have certain limitations. If you configure port access control lists (ACLs), extensions or policies in the virtual switch, SR-IOV is disabled because its traffic totally bypasses the switch.
    You can’t team two SR-IOV network cards in the host. You can, however, take two physical SR-IOV NICs in the host, create separate virtual switches and team two virtual network cards within a VM. "
    There is really a limitation when using NIC teaming :
    http://technet.microsoft.com/en-us/magazine/dn235778.aspx
    Best Regards,
    Elton Ji 
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected] .

  • WAAS issue with NIC teaming

    Hi,
    Can someone tell me what has the NIC teaming effect on WAAS.
    I was preparing a demo for one of my client but before this they were using another popular WAAS product. According to my client, they had a big network issue with NIC teaming, i.e one ip and 2 mac addresses with server loadsharing.
    scenario.
    Before the demo i just wanted to confirm that WAAS has nothing to do with the above mentioned problem...can anybody confirm...

    Hmm... Still not quite sure what your saying. It sounds like by coincidence the other accelerator box got the same IP as one of their servers. They should have been able to fix that quite simple, not to mention test for it by doing the equivalent of "show int" on the box before plugging it in.
    Or possibly they had some type of proxy arp configured wrong?
    Either way we're running WAAS boxes on our networks that have teaming of NIC's via HP's teaming utility using "Transmit load balancing" on the servers. The WAAS boxes are configured for ether-channeling their NIC's and using WCCP for traffic redirection.
    Actually, if you did them using WCCP rather than inline, there definitely shouldn't be a MAC conflict since the WAAS boxes will be on a different subnet at that point. No chance of a problem like that with Layer-3 separation...

  • Single invoice for multiple orders with different divisions

    Dear All,
    while I am trying to do single invoice for muliple orders with different divisons invoice is gettting splitted..In copy control vbrk routine I  tried with 003 and 007 etc..but result is same..what configuration need to be done for getting the single invoice
    Thanks In advance
    Regards
    CNRNAIR

    Hello
    single invoice for multiple orders with "different divisions" invoice is getting split
    FYI - Different Division means different Sales Area.
    So, sales doc (whether sales order, Delivery & Billing) is applicable to EXACTLY one sales area.
    Thus, combining docs with different sales area is practically impossible.
    Provided, you are using common division.
    Hope this assist you,
    Thanks & REgards
    JP

  • I created a form with Single Choice fields, 4 days with times listed. But, I want the user to only be able to choose one time, and the time chosen to be unavailable for other users. How do I do this?

    I created a form with Single Choice fields, 4 days with times listed. But, I want the user to only be able to choose one time, and the time chosen to be unavailable for other users. How do I do this? I have 4 blocks of Single Choice fields in order for the summary page to give me each day in the final report. But, I need the user to be able to make a selection of any day and time and that apointment to no longer be available to future users when they log in. Plus, when the user clicks on the time, they are unable to change their mind and choose another time. Here's the link if you want to see what I'm talking about: 2015-2016 Workload Apportionment Review

    I'm afraid not.    It's not rocket science but you need to do some coding. 
    You'll need to find a script (php) and save it to your local site folder.  Then reference the script in your form's action attribute like so.
         <form action="path/form-to-email-script.php" >
    The input fields in your HTML form need to exactly match the script variables. 
    I'm  assuming you're hosted on a Linux server which uses PHP code.  Linux servers are also case sensitive, so upper case names are not the same as lower case names.  It's usually best to use all lower case names in your form and script to avoid confusion.
    Related Links:
    Formm@ailer PHP from DB Masters
    http://dbmasters.net/index.php?id=4
    Tectite
    http://www.tectite.com/formmailpage.php
    If this is all a bit beyond your skill set, look at:
    Wufoo.com (on-line form service)
    http://wufoo.com/
    Nancy O.

  • In iTunes 10, I could type "Sinatra" in the search file, and would get a list of all tracks with "Sinatra" in any field.   In iTunes 11 I get these clever little windows, with nice arrows, but no lists to view.   What am I missing?

    In iTunes 10, I could type "Sinatra" in the search file, and would get a list of all tracks with "Sinatra" in any field.   In iTunes 11 I get these clever little windows, with nice arrows, but no lists to view.   What am I missing?

    Thanks for chipping in.   I discovered something after trying what you suggested.   I have quite a few collections of hits by year from Time Life and Billboard.  I've eliminated duplicate tracks that appear in both collections (or other CDs for that matter), but cross-reference the CD where I deleted the track and placed in in the comments section of the CD track I retained.   If I "search" by song name, only the remaining track appears.   But if I want to hear for example Classic Rock 1964, only those tracks remaining would be there when I pull up that CD.   So, I type "Classic Rock 1964,"  in the search field.  First the boxes on the right of the screen open up showing album icons.  Showing four tracks by album with a button to view 10 more, then four songs with an option to vies 18 more.   I finally noticed that at the top of the boxes is a blue band that reads, :Show Classic Rock 1964 in Music.  When I double click on this blue band, all 24 tracks from the original CD appear in the song list format even though I had deleted two of them because they appeard in a Beach Boys CD.   On those tracks, I had referenced Classic Rock 1964 in the comments field.    So, bottom line, Search will also look in the comments field if you click "filter by all" in the magnifying glass to the left of the search field.   And you can move all tracks that if finds into a song list by double clicking on the blue band.

  • How to fill a new single field in a Infocube with historical data

    Hello Everybody,
    We have an SD infocube with historical data since 1997.
    Some of the infoobjects (fields) of the infocube were empty during all this time.
    Now we require to fill a single field of the infocube with historical data from R/3.
    We were thinking that an option could be to upload data from the PSA in order to fill only the required field (infoobject).
    Is it possible? is there any problem doing an upload from the PSA requests directly to the infocube.
    Some people of our team are thinking that the data may be duplicated... are they right?
    Which other solutions can we adopt to solve this issue?
    We will appreciate all your valuable help.
    Thanks in advance.
    Regards.
    Julio Cordero.

    Remodeling in BI 7:
    /people/mallikarjuna.reddy7/blog/2007/02/06/remodeling-in-nw-bi-2004s
    http://www.bridgeport.edu/sed/projects/cs597/Fall_2003/vijaykse/step_by_step.htm
    Hope it helps..

  • Is it possible UPLOAD a single printer from an LDT with a lot of printers?

    is it possible UPLOAD a single printer from an LDT with a lot of printers? by using FNDLOAD
    here we can
    download a specific printer definition, we need to follow the below syntax
    FNDLOAD apps/ 0 Y DOWNLOAD $FND_TOP/patch/115/import/afcppinf.lct
    source_printer_def.ldt FND_PRINTER PRINTER_NAME=[printer name]

    Duplicate post -- migrate  printers, types, styles and drivers from an 11i to R12 instance us

  • Cisco CME integration with NICE recorder

    Hi Team,
    Please let me know if we can integrate Cisco CME with NICE recorder. If yes, please share the steps involved in configuration on CME side and NICE.
    Warm Regards,
    Dinesh Rathi

    Hi Anas,
    If the panasonic prtocol is H323 will be no problem the CME dial peer will configure as below:-
    dial-peer voice 121 voip
    translation-profile outgoing prefix
    destination-pattern x..
    session target ipv4:192.x.x.x
    dtmf-relay h245-alphanumeric h245-signal
    but if the panasonic protocol is SIP the configuration on CME will be as below:-
    voice service voip
    ip address trusted list
      ipv4 0.0.0.0 0.0.0.0
    allow-connections h323 to h323
    allow-connections h323 to sip
    allow-connections sip to h323
    allow-connections sip to sip
    supplementary-service h450.12
    no supplementary-service sip moved-temporarily
    no supplementary-service sip refer
    sip
      registrar server expires max 250 min 200
      no call service stop
    dial-peer voice 2000 voip
    destination-pattern y...
    session protocol sipv2
    session target ipv4:172.x.x.x
    dtmf-relay sip-notify
    codec g711ulaw
    no vad
    So please can you advise for the above if the two options are right or not??
    Thanks

Maybe you are looking for

  • USB driver for 2wie screws up everytime i boot into os 9.2.2

    Ok. I have a 2wire ethernet router which i used to get online now since the ethernet port decided to take a dump after an electrical storm. I have it connected via usb which i had to install some drivers to get it to work. When i play warcraft 3, whi

  • How to clear Statistical Postings from Cost Center

    Hi All, Is there a way to clear the statistical postings from the cost center it has been incorrectly posted to and be moved to the correct cost center? I think there is a way to do it by making debit and credit entries to the G/L account where the p

  • Fms ns tincan error

    Hi all, I get an very strange error when starting up flash client on our php page: ns: info.description: Invalid tincan object name (stream ID: 1). With this client I connect to an fms witch in turn gets a stream from an remote fms. In the dev envire

  • One mac being difficult on LAN

    Hi, wondering if anyone can help. we have a small LAN in our office, theres a switch, patch panel and router in the cupboard which connects 3 macs and 2 pcs with a RAID shared drive and a laser printer. two of the macs are a mac pro and powermac whic

  • Loosing routing information

    Hello, running Macbook pro with 10.6.5 and frequently I loose the ability to connect to my VPN server. when it happens I can't ping any adresses at my office but the internet http browsing still works. The only solution I found to make it work again