Run script in autosys at a specified time.

I have created a shell script.
I want to run the script in Autosys.
Please note that my shell script runs as "$ ksh run.ksh"
How do I make autosys run this script at 5:00PM every day?
insert_job: abc job_type: c
box_name: run.box
command: ksh run.ksh
machine: mach1
#owner: mach1@mymach
permission: gx,wx,me,mx
std_out_file: /x401/autosys/output/${AUTORUN}_${AUTO_JOB_NAME}.out
std_err_file: /x401/autosys/output/${AUTORUN}_${AUTO_JOB_NAME}.err
alarm_if_fail: 0
profile: /export/home2/prof.profile

Hi,
Please open a terminal and type crontab -e and press enter. The vi editor will open in command mode, press the I key to enter INSERT mode, Type the following line, substituting the full path for the one shown below, into the vi editor:
00 17 * * * /usr/bin/ksh run.ksh
Press the ESC key to exit INSERT mode and return to command mode, Type :wq to save and exit the file.
You can also specify a user that you want to setup a crontab entry for by doing the following command:
#crontab -e -u <user>
You'll want to replace the <user> with the username which you wish to set the crontab entry for.
Cheers
Terry

Similar Messages

  • How to schedule a concurrent request to run at a specified time/day?

    Hi All,
    How to schedule a concurrent request to run at a specified time/day (ex: Sunday 12pm)?
    Thanks,
    Chiru
    Message was edited by:
    Megastar_Chiru

    Is this to run periodically ?
    During the request submission, click schedule, choose the specific days, and click on S = Sunday.
    Change the start date on the date of the sunday you want to run, eg : 15-JUL-07 14:00:00, change the end date as well.

  • Running a Java program automatically at a specified time

    How to run a Java appln automatically at a specified time?

    Java Application, or method within a running Java application?
    To run Java you would have to use the OS native tools.
    Windows Scheduled Tasks
    Newbie: Intro to cron.
    To execute a block of code within a running Java VM, you want to look at Timer.

  • Can we run script logic at the time of preparing reports.

    Helo Everybody!
    I am new to SAP BPC.
    Can we run script logic at the time of preparing reports.
    Thanks & Regards,
    Satish.

    If you mean, "Can we run script logic at the time of preparing reports" is equivalent to entering data into the report and sending it to the database, then yes, you may run logic as Marcel indicates.  Defualt logic is ALWAYS run for ANY and EVERY set of data that is sent via an input template from the field.  You may also run logic when posting a jOURNAL entry as well.  But be careful....if default logic attempts to perform to MANY or COMPLEX calculations, the time it takes to complete the process may not be in expectations with the users plans.  There is a fine design balance required when planning to run logic at the time of input, as opposed to running in a package or at specific times during the day.
    Hope this helps.

  • Automatically run report at specified time

    Hi,
    Is it possible to run the specified report which is registered with Portal automatically at a specified time?!
    with best regards,
    Mathan

    Mathan,
    I'll assume you are talking about the Oracle Reports and Oracle9iAS Portal integration. Best bet would be to ask the Reports folks in the Oracle Reports forum.
    Rich

  • Time Machine Service - Run scripts after backup

    I am running Mavericks Server (10.9.5), server version 3.2.2
    The server is used as a backup destination for a lot of Macs, and I am trying to create a complementary service that keeps track of all of the incoming backups and logs all backup events.
    Is there any way to have a script execute whenever the Time Machine service completes a backup, or for that matter, and way to tell when a backup is running or has completed?
    The options I have thought of so far are:
    1. Script that monitors the logs to look for appropriate events
    2. Run script on timer that scans the backup folder and looks for new backups
    Neither of these seems ideal to mean, so I was hoping someone might have a better idea.
    Thoughts?

    In order to back up the configuration and state of some services the server needs them to termporarily be turned off.  This includes the backing up of Time Machine.
    So in order to back up the Time Machine configuration and details about what computers it is backing up where, the server would need to turn off the Time Machine backup service.  But if it's turned off, it can't use it to back things up.
    Similarly, imagine you needed to restore the backup.  To view the backups you would need the Time Machine backup service to be working.  But you can't overwrite the configuration and status information of a service which is turned on, because that would confuse the process doing the serving.  But if the process is turned off, you can't use it to restore the backup.
    So do what Linc said: use the System Preferences panel to back the computer up, and don't back it up to the same device you're backing up its Time Machine clients to.

  • How to Set Automatic to turn on and off at specified time my TV with STB

    It seems very frustrating talking with Verizon tech support, that's why I turn to you guys to find if anyone knows the answer to my question above.,from my experience calling verizon for my tech support regarding fiosTV and most of my experience from Verizon are either inept and giving the customer the run around by keeping you on hold for the longest and not having the answer after all the time I spend with the tech on the phone or they will tell you that the that there is no such thing; and when you call again when you get another tech on the phone you get completely different answer if not an inept answer. 
    My Specific question is, if  I turned off my STB (top box) and my TV at a particular time; and I like my TV with STB to turn on at a specified time ( example I turned off my STB and TV at 9:00 PM ) and would like my TV with the STB to be turn on like 11:00 PM to turn off at 12:00 midnight by itself, not to record  but just to turn on as reminder and to serve as power saver incase I fall asleep ( this is just example scenario). How would I do that? The manual of either remote control or the STB does not provide that information. My television manual say the TV can but I can not turn it on automatically with the STB connected.
    I called Verizon tech, he first sounded inept and sounded like he just talking from a scripted lines, and would not tell me straight forward that he does not know the answer; I  explained that I switched to Verizon Fios for its claim in high and advance technology as they compare themselves by far higher in technology as compared with Cable or direct TV, and with Cable Vision I was able to used the above automatic turn on and off with the remote; I asked for his supervisor or maybe more expert tech support, He turned over the call to his supervisor, who told me that the STB or the remote Fios TV does not have that level of capability which sounded to me like a joke, he also told me that the STB can not be turn on and off because STB is always set as on; I told him I can see the green light turns on and off on the STB each time I press the ON button on the Verizon Remote; he defended that its always on because the timer is ON, and he told me instead FIOSTV has another feature that although it will not turn the feature on and off automatically, it will serve as reminder, I asked him How to carry out that function, the tech supervisor said  to me to just press the record button on my remote, which I know right away that it will just record, and  I told him that its not what I want to accomplish, this Tech Supervisor insisted that it will not record but will set to notify me, but surely it did record and it just wasted and used my DVR memory capacity the time when he put me on hold for a long period of time, I knew it recorded because the red button on the STB/TVR was on., and it did not notify me in anyway what time the TV and STB will turn on. That was a complete  waste of time, instead of him getting the issue to higher level of their tech support and try to research thru and get back to the client. To me, simple feature as this, is such absurd to claim that fiosTV has more advance features than others, where infact they can not even have their tech support answer such simple question.  
    Any one here has any idea, please help.

    The set top box does not offer any auto on or auto off feature. 
    you can only do that if your TV offers the feature. 
    If neither your TV nor the STB offer that feature (in this case the stb does not offer) then you can go to a radio shack or a similiar store and purchase a AC timer.  they make them and you plug them into your wall, they are very cheap.
    I have had directv and fios and neither of my systems did an automatic on or off. 
    BUT my samsung TV upstairs does have that feature (auto on and off)   and I have not checked my mitsubishi downstairs. 
    so you may want to check your settings on your TV to see if it will do it, like my samsung does. 

  • Script error line 2053 the specified module could not be found URL res://ieframe.dll/preview.js

    Script error line 2053 the specified module could not be found URL res://ieframe.dll/preview.js

    The issue is caused when Windows creates the printer profile in the control panel that it doesn't correctly create it with the drivers.
    We're not going to completely uninstall all the HP software, instead we're going to remove the corrupt Windows printer profile and reinstall it.  Total time for this on an average computer is about 5-10 minutes to completely repair (including reboot).
    1) Navigate to Start Menu > Devices and Printers or Start Menu > Control Panel > Printers
    2) Select each printer profile for the printer with an issue, then select remove device/printer.
    3) Reboot
    4) Navigate to Start Menu > All Programs > HP > insert model # here > Add Printer (or Setup Wizard)
    5) Follow the setup prompts to reinstall the printer profile and it recreates the Windows printer.
    6) Run the HP Update Tool from Start Menu > All Programs > HP if your printer installs it, rebooting afterwards if necessary.
    7) Test by printing google.com (uses very little ink when the test page comes out).
    Let me know if you have any questions or issues.
    Thanks,
    Dan
    I work for an internation tech company and personally perform thousands of computer repairs a year. I'm based out of the US working for a US company, and have been working on computers for over 13 years.
    ****Click the White Kudos star to say thanks****
    ****Please mark Accept As Solution if it solves your problem****

  • Weather App that reports to your notification center at a specified time?

    Here's the scenario:
    I work outdoors and live in the Midwest so the weather can and often does vary A LOT from day to day.
    I plug my iPad in for the night and go to sleep.
    When I wake up, I hit the home button to see my notification center. Contained there is the report from this weather app, telling me the basic information immediately: Current temperature, the day's high/low, any preciptiation chance.
    Now here's the added bonus that I really want:
    Everyone knows the temperature changes drastically from night to day, so a temperature reading would need to be taken near to the time that you wake up. What if you could set this app to display the information at a certain time? It's a concept just like an alarm where an action is triggered at a specified time, in this case, weather readings. Say I'm getting up at 6am. I'd set the app to report at 5:55am or something like that.
    OR the much simpler apprach would just be to add a weather widget of some sort to the lock screen. If that's an option, I'd gladly go for that as well.
    So does anything like this exist?
    Thanks to all!
    [EDIT]
    I found the solution to my question. I had a feeling it was something really easy that I was just missing. Thanks! Feel free to delete this thread. I would but I'm not sure how or if I even can.

    You are correct that things would be easier if it was automatic. However, you will generally find that it is a program with a built-in scheduler, such as a backup program or a video recording program, that left some code behind even if the program was trashed or removed from the system.
    As far as the PDP11, I don't think I could afford the electricity to run one even if I had one. The PDP11 is the first computer I was exposed to in medical imaging. I list it because every once in a while it draws out the truth from folks like yourself when they admit to knowing what one is.
    I think the first disk drives that thing used were housed in recycled washing machines using the old motors to drive the spindles.
    -DP

  • Lock Frontpanel when user takes no activity in a specified time

    Hello !
    I have a PanelPC with Touchscreen and want to lock the frontpanel when the user doesn't make an input for a specified time. After this time the frontpanel locks and shows a password input to unlock the frontpanel. How do i detect if the user makes no input ? The VI has to run, because it makes an automatic control/ regulation of a factory. I found an example with a password protection, but i don't know how to detect the user input. Can anyone help me ?

    You can monitor the "mouse events" and also the "keypress events (using the keyboard)" and with this FP can be locked/unlocked based on the time out. 
    Create an event structure so that it will be easy to handle the mouse events. Add another frame of this event structure which can be used for handling the timeout and when ever a event occurs on the FP you can reset it to 0
    Regards
    Guru (CLA)
    Attachments:
    timeout.vi ‏13 KB

  • Run Script action not working when verifying bundle

    I have a critical "Run Script" action in a bundle. When verifying the bundle, the script doesn't seem to run and the verify action hangs indefinitely.
    I see the following lines in the ZCM Log:
    Code:
    [DEBUG] [07/21/2011 19:05:48.670] [5880] [runscriptenf] [1] [TeachGH] [Run Script Action] [] [Found script engine cmd.exe. Not using it since cmd.exe does not take parameters.] [] []
    [DEBUG] [07/21/2011 19:05:58.311] [5880] [runscriptenf] [1] [TeachGH] [Run Script Action] [] [Run Script Action - Ended - 7:05:58 PM] [] []
    nothing else is logged after those 2 lines. It seems like ZCM decides not to run the script for some reason, but is still waiting for it to complete? Or is it possible that it has moved onto the next action, but it is hanging there and not reporting it to the log?
    I have no time to troubleshoot right now, will do so in depth tomorrow. Just wanted to get this posted in case anybody has a clue.

    Nevermind, the next action is running, and that is what is hanging, which I doubt is Zenworks fault... Time for some more troubleshooting.

  • Job not released in the given specified time(Job_close)

    Hi,
    I need to run a program through job.I created a job using JOB_OPEN
    And submitted the job name and job count to the required program
    And closed the job using JOB_CLOSE.
    My problem is the job getting scheduled but not released/ processed automatically by the specified time I need to release it manually through SM37.
    My code.
    JOB_OPEN
    SUBMIT VIA job_name and job count
    l_time = sy-uzeit + 60.
    CALL FUNCTION 'JOB_CLOSE'
                EXPORTING
                  jobcount             = l_jobcount
                  jobname              = l_jobname
                  SDLSTRTDT            = sy-datum
                  SDLSTRTTM            = l_time
                  STRTIMMED            = 'X'
                IMPORTING
                  job_was_released     = l_released
                EXCEPTIONS
                  cant_start_immediate = 1
                  invalid_startdate    = 2
                  jobname_missing      = 3
                  job_close_failed     = 4
                  job_nosteps          = 5
                  job_notex            = 6
                  lock_failed          = 7
                  OTHERS               = 8.
    After the above code execution SY-SUBRC is ‘8’ and And the L_released is having balnk.If I pass start immediately the the job processed immediately. And the L_released is having ‘X’.
    Please help me….

    If you are trying to set up the job to start at some point in the future - use the SDLSTRTDT and SDLSTRTTM, but do not set the STRTIMMED to 'X'.  You can either schedule it for the future (with the sy-datum and sy-uzeit+60 you desginated) or you can set it to begin immediately.  But I don't believe you can do both.
    In your code example, your are setting both the "start immediately" plus giving it a future date and time.
    Give that a try and see if it helps.
    -Mark

  • How can I disarm the counter in a specified time?

    I am using 6602 counter. I use 2 counters to perform "Buffered Period Measurement ". I use internal time base (20MHz) as the SOURCE, and wire the signal to the Gate. The counters are triggered by a trigger signal.
    Now I just want to stop counting the signal in a specified time after the counters triggered. After that time, even the input signal is still running,the counting must be stopped. How can I implement this purpose? I don't know how to disarm the counter when the counter are still running, and how to exactly determinate the stop time.
    Thanks for any advise. I have attach my present routine here.
    Attachments:
    counters.vi ‏192 KB

    Just to expand a bit on Justin's answer to outline a few particulars.
    You mentioned using 2 counters to capture buffered periods so I'm assuming that you'll enable triggering to guarantee that they both have the same start time. Note that in this scheme, element #0 of your array of buffered periods will represent the time from the Trigger edge until the first Gate edge.
    Since your description made it sound acceptable to ignore pulse periods occurring later than the interval of interest, perhaps you can collect data for a little longer than necessary, then reset the counters and trim off the periods that came in "too late" using 'Array Subset.' A quick-and-dirty way is to loop over each array of periods, performing a cumulative sum until it exceeds the specified data collection time interval. That'll tell you the length of the subset you need to keep.
    The hard part is that after starting the measurement, you'll need to poll task attributes/properties to determine when the trigger has been received. Only after that's been determined would you start keeping track of approximate time in software.
    There are ways to do the timing in hardware if you get more of the 6602's counters involved. Here's one way:
    1. First configure your 2 counters for buffered period measurement. However, instead of using the internal timebase for a Source, use another counter's output as a Source. Under DAQmx, the internal routing details are handled for you; under traditional NI-DAQ, you'll need to make explicit routing via RTSI.
    Note that in this scheme, these 2 counters don't need to be triggered.
    2. Next, generate a finite-duration pulse train at 20 MHz (examples can be readily found under LabVIEW help or this website). This pulse train should last for your data collection time interval, and will act as the Source signal for your period measurements. It is important that the period-measuring counters are started before the finite pulse train.
    The finite pulse train uses 2 counters -- one to generate the output pulse train at 20 MHz and a "helper" that produces a single pulse whose duration equals your data collection interval time.
    If you need to synchronize to some external trigger signal, you can set the "helper" counter to be triggered, but there'll be one subtle catch. The first period measurement in your buffers will not include the time from the external trigger signal until the beginning of the single "helper" pulse, i.e., the "delay" time spec for the pulse. You can either make this very very short and ignore it, or make it any convenient duration and then add it to the first period measurements. Be careful though: the timebase for this "delay" time isn't necessarily the same as the timebase used to measure periods.
    There's quite a bit of complication there, so let me suggest an easier way that assumes no need to synchronize to an external trigger. (I'll use DAQmx terminology, since the traditional NI-DAQ would get complicated again with explicit RTSI signal routing.)
    A. As describe in #1 above, configure your period-measuring counters to use a 3rd counter's output as the timing source terminal.
    B. After starting your 2 period-measuring counters, start up the 3rd counter to generate a continuous 20 MHz pulse train.
    C. After the 3rd counter starts, call the 'Wait (ms)' function from the Time & Dialog palette. Wait for slightly longer than your desired collection time.
    D. Read all buffered periods from the counters. You may need to first query each to find out how many are waiting to be read.
    E. Reset all 3 counters.
    F. Do the cumulative sum work on the two buffered period arrays to determine where each should be truncated.
    Note that step "C" above will leave you stuck while data is being collected. A small variation would be to read a reference time ("Tick Count (ms)") right after starting your 20 MHz counter, then set up a loop that allows you to terminate early (logical OR of, say, "abort" button, data acq error cluster error, and time comparison). In that loop, you put a delay of maybe 50-200 msec using "Wait (ms)."
    "Wait (ms)" will output a tick count from which you subtract the reference time. When the difference exceeds your data collection time, you can exit the loop and continue with step D above.
    -Kevin P.

  • Error submitting tasks: Operation could not be completed within the specified time

    I've created a Batch Application and I'm having an issue running a job.  Its suppose to synchronize 2 azure blob containers.
    In my JobSplitter, I compare 2 azure blob containers and find the files in the first container that need to be copied over to the second one.  Just figuring out which files to copy over can take about 5 to 6 minutes the first time this is run depending
    on the number of files that need to get copied over.
    Once we have the files that need to be copied, we group them into sets and create a task for each set.
    The exe that the TaskProcessor runs doesn't do anything just yet. All it does is write the arguments sent to it into a file. Nothing major.
    On the last run, about 900 tasks were created. Four of the tasks completed successfully. I can download the output files for them just fine. The next 4 tasks failed with an error.
    Looking in the JobLogs, I see this:
    The job orchestrator finished
    Failed to process job ac8dd4a3-d882-4ec1-847d-48844fa3e1f4: Error submitting tasks: Operation could not be completed
    within the specified time. RequestId:27eab612-c8ce-4e4b-8dfb-00e7024c71ec Time:2015-01-29T00:37:03.5943898Z
    Has anyone seen this before?
    Thanks,
    matt

    This error is usually a transient error, typically related to an internal storage timeout.  We're working on a fix for it.
    In the meantime, if you go into the Batch Apps portal, select the failed job and click Reprocess in the command bar, Batch Apps should re-run the failed tasks and the not-run tasks.  (Note that the tasks that already succeeded will not be re-run, and
    we will not re-run the job splitter to create new tasks.)
    Please let us know if you continue to see this problem or if reprocessing the job doesn't work for you.

  • Getting the below error when running the Baseline.grf for the first time

    I am getting the below error when running the Baseline.grf for the first time.
    Appreciate your support in resolving it.
    Error below:
    INFO [main] - *** CloverETL framework/transformation graph, (c) 2002-2012 Javlin a.s, released under GNU Lesser General Public License ***
    INFO [main] - Running with CloverETL library version 3.2.1 build#63 compiled 04/01/2012 12:53:21
    INFO [main] - Running on 4 CPU(s), OS Windows 7, architecture amd64, Java version 1.6.0_20, max available memory for JVM 901120 KB
    INFO [main] - Loading default properties from: defaultProperties
    INFO [main] - Graph definition file: graph/Baseline.grf
    INFO [main] - Graph revision: 1.114 Modified by: mkressirer Modified: Thu Apr 12 13:27:18 EDT 2012
    INFO [main] - Checking graph configuration...
    INFO [main] - Graph configuration is valid.
    INFO [main] - Graph initialization (Baseline)
    INFO [main] - [Clover] Initializing phase: 0
    INFO [main] - [Clover] phase: 0 initialized successfully.
    INFO [main] - register MBean with name:org.jetel.graph.runtime:type=CLOVERJMX_1306871483270_0
    INFO [WatchDog] - Starting up all nodes in phase [0]
    INFO [WatchDog] - Successfully started all nodes in phase!
    INFO [RUN_GRAPH1_0] - Running graph ./graph/InitDataStore.grf in the same instance.
    INFO [RUN_GRAPH1_0] - Checking graph configuration...
    INFO [RUN_GRAPH1_0] - Graph configuration is valid.
    INFO [RUN_GRAPH1_0] - Graph initialization (InitDataStore)
    INFO [RUN_GRAPH1_0] - [Clover] Initializing phase: 0
    WARN [RUN_GRAPH1_0] - WS messenger cleanup failed.
    java.lang.NullPointerException
         at org.apache.axis2.client.Stub.cleanup(Stub.java:134)
         at com.opensys.cloveretl.component.WebServiceClient.free(Unknown Source)
         at org.jetel.graph.Phase.free(Phase.java:487)
         at org.jetel.graph.TransformationGraph.freeResources(TransformationGraph.java:681)
         at org.jetel.graph.TransformationGraph.free(TransformationGraph.java:955)
         at org.jetel.graph.runtime.PrimitiveAuthorityProxy.executeGraph(PrimitiveAuthorityProxy.java:149)
         at org.jetel.component.RunGraph.runGraphThisInstance(RunGraph.java:511)
         at org.jetel.component.RunGraph.runSingleGraph(RunGraph.java:409)
         at org.jetel.component.RunGraph.execute(RunGraph.java:302)
         at org.jetel.graph.Node.run(Node.java:414)
         at java.lang.Thread.run(Thread.java:619)
    WARN [RUN_GRAPH1_0] - Some graphs wasn't executed (because graph "./graph/InitDataStore.grf" finished with error).
    WARN [RUN_GRAPH1_0] - Some graph(s) finished with error.
    ERROR [WatchDog] - Graph execution finished with error
    ERROR [WatchDog] - Node RUN_GRAPH1 finished with status: ERROR caused by: Graph './graph/InitDataStore.grf' failed!
    ERROR [WatchDog] - Node RUN_GRAPH1 error details:
    org.jetel.exception.JetelException: Graph './graph/InitDataStore.grf' failed!
         at org.jetel.component.RunGraph.execute(RunGraph.java:324)
         at org.jetel.graph.Node.run(Node.java:414)
         at java.lang.Thread.run(Thread.java:619)
    INFO [WatchDog] - [Clover] Post-execute phase finalization: 0
    INFO [WatchDog] - [Clover] phase: 0 post-execute finalization successfully.
    INFO [WatchDog] - Execution of phase [0] finished with error - elapsed time(sec): 2
    ERROR [WatchDog] - !!! Phase finished with error - stopping graph run !!!
    INFO [WatchDog] - -----------------------** Summary of Phases execution **---------------------
    INFO [WatchDog] - Phase# Finished Status RunTime(sec) MemoryAllocation(KB)
    INFO [WatchDog] - 0 ERROR 2 20132
    INFO [WatchDog] - ------------------------------** End of Summary **---------------------------
    WARN [exNode_0_1306871483270_RUN_GRAPH1] - Attempt to unregister non-registered thread in the ContextProvider.
    ./graph/InitDataStore.grf: Execution of graph failed! Error during graph initialization: Phase 0 can't be initilized.
    INFO [WatchDog] - WatchDog thread finished - total execution time: 2 (sec)
    INFO [main] - Freeing graph resources.
    ERROR [main] - Execution of graph failed !

    It can't find an Endeca specific class when running via the clover command line utility. Thus, the classpath being set in that shell script is not incorporating the .jar files where the endeca-specific classes are packaged. I would start by adding an line to see what your classpath is set to. There are actually already some lines of shell script in clover that you can uncomment to see what .jars are getting loaded:
    #echo $CLOVER_LIB/*
    for i in $CLOVER_LIB/*.jar $CLOVER_LIB/*.zip; do
         LOCAL_CLASSPATH="$LOCAL_CLASSPATH:$i"
    done;
    #for i in `ls $CLOVER_LIB/*.jar`; do
    #echo $i
    #done;
    You could also echo LOCAL_CLASSPATH to see what is getting set there. At the end of the day, you will need the endeca-specific jars to load which can be found here: /Endeca/Discovery/2.3.0/Integrator/plugins/com.endeca.latitude_1.0.0/*
    HTH,
    Dan
    http://branchbird.com

Maybe you are looking for

  • Missing file - warning msg ?

    When I open my ibooks author file I get a missing file warning. The warning window show the missing file name but no other information. How can I find the page where this file is missing and fix the issue? thanks in advance Rohit

  • Mac Mail Sent File bogging down Mail, and entire system

    At Mail start up, when I go to my Sent File, it appears to be attempting to update/access the file (that shouldn't need that much updating).  The small pie chart icon that shows progress next to the Sent Folder starts, but doesn't progress past the f

  • BPM with Synch Interface

    Hello I have scenario Sysnh HTTP -> BPM. I have control step in BPM that cancel process in case of error. When the process is canceled sysch sender does't get error immediately. Sender wait until timeout. Is it possible to configure that IE must retu

  • Macbook system preferences won't save

    My system preferences, such as dock and trackball settings don't save when I restart my computer.  After setting all preferences to my liking, added and removed apps from the dock, even moved the dock itself only to find everything upset when I turn

  • System migration / Cloning - Copying to temp HDD then copy back to new Mac

    Well, what I need... An instruction how and using what to copy/clone my system firstly to external USB drive then to other (same) Macbook. Precisely, I have MacBook black one, 80Gb, external HDD is 120Gb... used space on OS X (10.4.8) partition is 34