Serial RS232 directly to a USB DAQ?

Hello,
I have a question regarding serial communication: is it possible to directly hook a device via RS232 serial to digital pins of a USB-6211 DAQ? (Or maybe even a USB-6008?)
If so, where should I wire the pins to?
If not, could you recommend me a not too expensive, yet functional RS232 to USB adapter which could work fine? (I am planning to interface a Datex capnometer or a Fresenius Pilot C infusion pump first, however if I could find a relatively well-priced multi-port adapter I would go on with both. BTW, can I include more NI-VISA queries in parallel in LabVIEW?) 
Thanks
Engage! using LV2012
Solved!
Go to Solution.

The main difficulty is that I am not familiar with these devices. I thought it was not suitable because all the pages say that cables based on these chips are for 3v3 to 5v connections between an arduino and a pc, while there are some more expensive cables which do not mention uart or 3v3 connection.
Should I worry about this or can I go on with these chips?
Engage! using LV2012

Similar Messages

  • I am trying to authenticate at Filevault preboot using external Serial (RS232) to USB convertor where USB port is connected to my mac machine.But on preboot I am not able to type the password using console where my machine is connected.

    I am using an external keyboard which is actually a Device KeyAT who do the keyboard simulator kind of operation over Serial (RS232) to USB connector.
    I have a controller machine connected with Serial Port and MAC machine is connected by a USB port to that device.
    I am able to type the password on OS X login screen but on using the same device and set up on Filevault preboot I am not able to type the password.
    This connector is detected as a USB 2.0 composite device in System Hardware table.
    Can someone hints or point out a potential cause or to rectify this issue.
    Thanks in Advance.

    Which os version are you using? 
    Which iPod Nano model do you have?  iPod Models 
    iPod not recognized in iTunes and Mac desktop 

  • How to generate a bipolar pulse train in LabView using USB DAQ 6211?

    Hi,
    I am setting up a system to generate either a single square pulse or a train of square pulses using LabView, with controls to adjust the frequency, amplitude, number of pulses etc. I have had a lot of help from NI tech support setting up the actual VI itself which seems to be working fine, and outputting the pulses via a USB DAQ 6211 using a square waveform generator and the AO1 channel on the DAQ.
    The problem that I now have is that I need to pulses generated in a train to be bipolar (as they are connected to electrodes so need to be bipolar o avoid salt build up on the electrodes from the voltage going in one direction only, at least that is how I understand it!).
    How can I set up my LabView VI to generate a bipolar pulse train instead of always being positive voltage? I am new to this area and so am trying to learn but there is so much to learn!
    Thanks,
    spamjam

    Hi Shalini,
    Apologies for taking a while to get back to you, I hope I can explain what it is that we need to create with the pulses. I understand what you mean about the existing pulses having a positive and negative on the graph - but we need the pulses to start from a resting voltage and the first pulse to be positive, then back to zero, then the second pulse to be negative then back to zero etc. This is to do with reversing the direction of the current between two electrodes to prevent build up of salts on one electrod from the current always passing in the same direction. 
    I have attached a .Tif file to this post to try to illustrate what I mean - the top picture shows how the pulses are currently generated, then bottom on is what we would like to produce if this is possible?
    Thanks for your help,
    Spamjam
    Attachments:
    Slide1.jpg ‏38 KB

  • SR400 change from GPIB to serial RS232

    Hello! 
    I am new to labview. I was given the task of changing our SR400 gated photon counter from GPIB interface to serial RS232. I am not quite sure to go about this with the code I was given. 
    The sr_400 count VI writes parameters to the SR400 and then reads the data from it using the GPIB. What is the easiest way to change the VI so it uses serial RS232? Should I just removed the GPIB parts in SR400 A gate and Read and replace them with the example for RS232? 
    I would appreciate your help.
    Thank you,
    Maira
    Attachments:
    sr_400 count.vi ‏19 KB
    SR400 Read.vi ‏20 KB
    SR400.LLB ‏132 KB

    Do I need to add a configure serial port function for the write and read part or will one be enough? 
    Do I just directly replace the GPIB functions or do I also need to alter the stacked sequence structures?
    I'm sorry to bother you but I really don't know anything about labview. 
    -Maira

  • What is maximum read out speed of USB DAQ 6343

    hello everyone,
    we have new USB DAQ 6343.Its application note(or say characteristcs) says that it's sampling rate is 500K Sample/second.Now i need some clarification from you guys.I have to read digital data(serial or parallel). so plz tell me how much far I can go with this product for both ways.
    thanks in advance, 
    Solved!
    Go to Solution.

    Unfortunatly I can't get the spec online
    Error
    You are not authorized to view this document
    but you should have get it with your device
    However the datasheet is telling me something like 500kS/s aggregate (500kS/s / <number of channels read> ),  but up to 1MS/s for digital input. However you need to get the data into your PC. If you read one 8 bit port @1MS/s the USB should be able to handle the datastream.
    Greetings from Germany
    Henrik
    LV since v3.1
    “ground” is a convenient fantasy
    '˙˙˙˙uıɐƃɐ lɐıp puɐ °06 ǝuoɥd ɹnoʎ uɹnʇ ǝsɐǝld 'ʎɹɐuıƃɐɯı sı pǝlɐıp ǝʌɐɥ noʎ ɹǝqɯnu ǝɥʇ'

  • Can I write directly to a USB virtual port ?

    I am using a Zebra TLP 2844 printer connected via USB.  It does not generate a conventional serial port but is shown as a virtual printer port in the printer config.
    For some reason, the newer driver does not provide the ability to rotate my label 90 degrees and I need to send a printer cmomand straight to the printer.
    Any options for this ?
    May end up having to find the older printer driver that provides for 90 degree location.
    Note this is not a Portrait / Landscape issue as I have many other systems already printing correctly but this is yet another  "Upgrading to Windows 7" issue I have run into.
    Thanks for any thoughts...
    Doug
    "My only wish is that I am capable of learning each and every day until my last breath."

    At least one other install is also Win 7 running LV 2011 though that should have no effect.  Am using the MS Word specific print functions to populate fields (bookmarks) in a word document (for a label) and sending it to the printer.
    The Word document I am using on the other machine prints fine.  On this new setup, it prints incorrectly (rotated 90 degrees so only part of the information prints on the label).  I am using the latest driver. The other machine may not though so I had considered rolling the driver back to a previous version.
    Continuing to work on it, I found that an alternate version of the label that I had on hand would print ok.  Tried to compare all the settings between the good printing label and the not good one.  Tried adjusting all that to no avail.  Finally made a copy of the good printing one and pasted the required text and bookmarks and saved it and now it will print.
    It seems that the page layout, margins and such are very critical when printing to a small label on this printer. (Label is only 1.75 wide by .75 high)  If I tried to adjust the margins and shift the content, it would change how the label printed (rotation) and I could never recover back to printing correctly.
    I am going to file this as a "barely stable document/printer situation" and hope it doesn't take a wild turn.  Will make my label document read-only so that it won't inadvertently get changed.
    The reason I wanted to write directly to the USB was to send a raw printer command to rotate the print 90 degrees.  Hopefully I won't have to figure out how to do that now.
    Case closed for me at this point.
    Thanks....
    Doug
    "My only wish is that I am capable of learning each and every day until my last breath."

  • RS 232 TO USB DAQ

    Hi,
    Is is possible to sync. RS 232 with USB DAQ 6008? i have a GPS mouse and i am woundering whether i could, physically wire each individual ports of RS 232 (output port) with NI USB DAQ 6008 and read the data in labview. thankyou.
    sincerely,
    solomon

    Yes if the baud rate is low enough for the 6008. Rember there is about 11 bits per byte (start data parity stop) and you want to over-sample at a factor of 10 or for each bits cell time.
    Converting the data stream to something that can be aprsed wll be like designing a chip for serial. THen you have to pars the data.
    It will be an excellent learning adventure so have fun.
    If this is not jus to learn something, I'd suugest you look into purchasing a widget that will give you GPS sync'd time pulses.
    Trying to help,
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • USB DAQ with ARM controller boards

    Hello,
         I wish to use USB DAQ (for example USB6509) with ARM or CORTEX-M3 board. I recently purchased one cortex - M3 (by luminary micro) from NI with labview embedded software. I wish to control and monitor large number digital I/Os using USB6509 but the controller card i wish to use is cortex-m3 boards. 
    can some one tell me is it possible at all? if yes, how to go about this? 
    thanks in advance
    Nabhi

    Hi Andy,
    There are a few interfaces that can be used depending on the data you want to send.
    If you want to use Wifi then dongles will be difficult as you would have to write a USB driver for this.  The simplest method would be to use a WiFi ethernet access point to put it on the network.
    If you are looking at general wireless technologies there is quite a lot based on serial technologies.  If you look at http://www.active-robots.com/products/radio-solutions/index.shtml there is a lot based on RS-232 which is available on the ARM7 board.  You may also find some that are based on UART ports, SPI or I2C that should be able to connect.
    I also wanted to draw your attention towards the SingleBoardRIO. It offers the form factor but is much more powerful by allowing you alot of DIO and programmable FPGA.  This is a single board version of the CompactRIO which has the same features but is larger and heavier so depending on the project may not be suitable. Check out ni.com/singleboard and maybe get in touch with your local NI branch for more information.  The SBRIO will offer the same connectivity options as the ARM board with the WiFi access point the simplest way to connect.
    Cheers,
    James Mc
    ========
    CLA and cRIO Fanatic
    wiresmithtech.com/blog

  • LAVA Gives away NI $150 USB DAQ

    The LAVA website is giving away a NI USB DAQ worth $150 in the latest coding challenge.
    http://forums.lavag.org/index.php?showtopic=3423
    Michael Aivaliotis
    VI Shots LLC

    Hi Lynn, thanks for the response. I'll try to answer all of your questions.
    I'll scope the outputs with an oscilloscope but the rated rise time on the encoder is quick enough that it shouldn't be an issue. I also run the program on just one analog input with no problems. I figure if there was noise in the encoder signal it would show up no matter how many analog inputs I'm sampling.
    When I run two inputs I have error -200019 coming out of the DAQmx Read VI. This error doesn't show up on just one analog input, only when I run two and only when the behavior that I describe in the next paragraph shows up.
    The zeros are in my written data but you can clearly see them in the measurement window. The attached picture is what my front panel looks like after a successful run. When it doesn't sample correctly the primary graph (cylinder pressure) drops to zero after between 50-150 samples. I open the spreadsheet and I see that it's recorded primarily zeroes.
    I've tried this on both Windows 7 and XP to the same results. I am aware of the XP USB connectivity issues and I installed the necessary Microsoft patch. The card is connected directly to a USB port, I believe it's 2.0. If by load you mean how much avalaible memory and CPU power is available, it doesn't look I'm even close to maxing out the PC. I tried closing excess programs as well as disabling all the other functions of the Labview program (analyzing and writing to file) to see if I was asking it to do too much at a time.
    Attachments:
    v34 Screenshot.JPG ‏432 KB

  • I am trying to reinstall CS3 from a download I bought several years ago, and it is saying my serial number is invalid.  I am taking the serial number directly from the list of products on my Adobe account.  Please advise

    I am trying to reinstall CS3 from a download I bought several years ago, and it is saying my serial number is invalid.  I am taking the serial number directly from the list of products on my Adobe account.  Please advise

    Uninstall and try the Adobe Creative Suite Cleaner Tool before reinstalling - it helps resolve installation problems for CS3 thru CS6 and for Creative Cloud
    http://www.adobe.com/support/contact/cscleanertool.html

  • TS2529 I am unable to backup my iphone 5 iOS 6.0.1 (connected directly to laptop USB) with my itunes 11 for Win 7 64bits. The process starts and fails to complete giving the error: itunes could not complete backup of iphone because iphone disconnected.

    I am unable to backup my iphone 5 iOS 6.0.1 (connected directly to laptop USB) with my itunes 11 for Win 7 64bits. The process starts and fails to complete giving the error: itunes could not complete backup of iphone because iphone disconnected.
    I have restarted the PC, the iphone, changed the lightining cable and nothign resolves it: backup never completes.

    Hi, I disabled the antivirus and the firewall. Same result
    I even deleted the backup folder inside C:\Users\...\Apple Computer\MobileSync\Backup to eliminate any corruption in the old backup files.
    Nothing changed: Session either times out or i get the same error message: itunes could not back up iphone because iphone disconnected. It always happens during step 3 out of 4 which is "transfering purchased apps from iphone to PC" and comes after step 2 which is backup.
    My iphone 5 is not jailbroken, and is a factory unlocked phone.
    Any other suggestion?
    Pls help

  • How do I update a program written for a Legacy DAQ into one for a USB DAQ?

        I am trying to rewrite a program, replacing all of the AI Waveform Scan and AO Update Channel VIs in it with DAQmx VIs. This seems to be the only way for the USB DAQ to respond to the program and not get any errors. I was just hoping for some help in how to replace those VIs with updated DAQmx ones. Attached is the part of the program that I am working on. There is a slight error because of some changes I have made, but the gist of the program is still there.
    Thanks!!
    Attachments:
    DAQdriver.vi ‏52 KB

    What I would suggest is that in either your init state or outside the loop, create two separate tasks for the analog in and the analog out. This means using separate DAQmx Create Channel, DAQmx Timing, DAQmx Start Task, etc. Then, you would have the tasks in your shift registers and pass just the appropriate task to either a DAQmx Write or DAQmx Read. No need to pass channel or device. In the End state, you would add a DAQmx Clear Task for each.

  • Is it possible to burn onto CD a 1hour voice recording recorded via your ipod2 directly to a USB external hardrive CD burner attached to your ipod via USB, without having to use itunes or be online (wifi).

    Is it possible to burn onto CD a 1hour voice recording recorded via your ipod2 directly to a USB external hardrive CD burner attached to your ipod via USB, without having to use itunes or be online (wifi).
    i would like to reduce my carry load when traveling abroad with work, and if this did work then great no more lumpy laptops Mmmmmmmm nice.

    No, you cannot do that at this time.

  • Working directly from a USB on apple applications

    I've been given over 1,000 photos to put into a slideshow with special effects on imovie. My Snow Leopard is already low on space, so I refuse to put the photos on the hardware. I work a lot on imovie and it often has to restart or freezes because I have so much data. Is it possible to work directly from a USB on imovie/iphoto without putting the data actually on the hardware?

    no so i dont know what happened

  • WiFi device that plugs directly into the USB slot on a printer?

    My next door neighbor has a MacBook with Airport installed.  She wants to use the portable around the house and send documents to a printer located in the basement.  She does not need a router to network additional devices, so what is the most reliable, reasonably priced device that plugs directly into the printer's USB port without the use of a cable (e.g. device with receiving antenna)?  Thanks.
    Bob

    Well, Badunit, it's more convenient and takes up less room if it plugs directly into the USB port, plus you save the cost of a cable unless one ships with the unit.  Here are two I found at Amazon:
    http://www.amazon.com/Compact-Wireless-802-11n-Newtork-Adapter/dp/B002VVITG8/ref =sr_1_6?ie=UTF8&qid=1311880281&sr=8-6
    http://www.amazon.com/802-11g-Wireless-Long-Rang-Network-Adapter/dp/B0035H4164/r ef=pd_cp_e_4
    Trouble is, they have too many negative reviews.  Besides, just how well do they work with the Airport Extreme card since most of these reviews are not Mac related, and those that are are negative?
    I'd like a device that is guaranteed to work well with the 2008 MacBook Airport card as the broadcast device.  Perhaps she will have to rely on a separate Linksys router with print server.

Maybe you are looking for

  • Iweb text as image -- help!!!

    I can't understand... I used the black template and I had two different behaviors: in the "about me" page the text box on the left after the publishing has been exported as image (keeping the hyperlinks) while all other pages every text box has been

  • New Zen Firmware Prob

    I got my New Zen today and I played it for two hours.Now I got a very problem. It appeared Firmware problem. I can not turn it off and everything does not work even I reset it. I try to use new firmare but I can not do anything because the firmware p

  • 500 minutes world planminutes status not avaiable online

    I subscribed 500 minutes world plan last month. Verizon said I will be able to check my minutes online. However, when I go to world plan Manage page there are no minutes. I have called customer service and have spent several hours but they couldn't s

  • One Components into 2 different panel problems

    Hi, I have one component, just call it A, and 2 different panels just call it PA and PB. I put A into PA and then I put A into PB, and display PA & PB into screen together. The problem is A is missing in PA but displayed into PB. I know this is behav

  • Language change for standard text

    How to change the language of standard text. ex; from 'EN' to 'CS'