Settings for inspection point user field

Hai gurus,
i want to know the settings for inspection point user field(150)
1) Field combination = 150
2 )Inspection type = ?
3) Functional location- field active  = ?(predefined field)
under user field
1)Text length 18 - Field active = ?
2)Text length 10 - Field active = ?
3)Number  length 10 - Field active = ?
4)Number length  3 - Field active = ?
5) Date - Field active = ?
6) Time - FIeld active = ?
waiting for positive reply.
regards,
sekar chand

dear Sekar
1) 150 inspection point is maily used for production related inspection. 03 , 04 . it is a freely defined inspection point which means you want to carry out several inspections for each operation during the production process
2) It is not Inspection type it is inspection point type- There are mainly 3 inspection point type
Freely defined - explained
Equipment related - You need this inspection point type if you want to carry out calibration inspections and record the results of test equipment inspections or inspections of functional locations
Inspection points to identify samples-You need this inspection point type if you want to manage samples and record inspection results for physical samples
3) Predefined field is for identification of the inspection point.
Example for inspection point type  1
For inspection point type 1 (inspection point for equipment) that is used, for example, in a calibration inspection, the equipment number must be entered. (To access the results recording function, however, you can use a different key word instead of 'equipment number', such as, 'test equipment').
Example for point 3
The sample-drawing procedure determines the number of samples to be taken. The system automatically creates an inspection point for each sample.
4) User fields are again identification. You can add in key work text which will appear while result recording.
5) Field Active  -This helps in sorting out the user fields.  An identification field is only active if you have made an entry in this field.Fields with numeric entries are required fields. The numbering sequence that you define for these fields uniquely identify an inspection point.
a typical example can be User field/field active/keyword combination
1)Text length 18 -1 -Inspector Name
2)Text length 10 - 2- Location
3)Number length 10 - 3- Shift No
4)Number length 3 - 4- Section No
5) Date - 5- Date
6) Time - 6-  Time
please Date and Time populates automaticaly. it is not mandatory that you use all the fields
Hope this helps
Regards
gajesh

Similar Messages

  • Inspection point user field

    Hi
    Inspection points i want to activate 3 userfieds -- for free text
    but in standard only 2 fields for free text, 2 for numeric 1for date and time
    how can I change any one the numeric into text field?
    Is it possible to increase the field lengh?
    plz guide me
    thanks
    Sami

    Dear Sami
    I dont this this can be done thru in standard. Kindly check the below exits for the possibility
    QAPP0001  User exit QAPP 1 (create inspection point)
    QAPP0002  User exit QAPP 2 (create inspection point & other data)
    QAPP0003  User exit QAPP 3 (IDI: inspection point and other data)
    QAPP0004  Customer exit 4 for insp. point proc. (partial lot default)
    QAPP0005  Create partial lot
    QAPP0006  User function key call 001 (CTRL-F11) and confirmation ID
    QAPP0007  User function key call 002 (CTRL-F12)
    Regards
    gajesh

  • How to reset all Internet Explorer 8 settings for a different user profile?

    Sometimes users on locked down PCs that need their IE settings reset to resolved issues such as improper/old cached credentials stored in the browser after a password change etc.  These issues can be resolved by opening
    Internet Options, Advanced tab, Reset, Delete All, Reset.
    The users cannot do this because the Advanced Tab is hidden by policy.  If an administrator logs in with a different account, of course, anything they change is in their profile and not the user's profile.
    Is there some way for an administrator user to log in and access Internet Control Panel settings for a different user's Internet Options so they can reset the browser for a limited user?
    We need a more streamlined way to do this instead of needing to either blow away the user's entire Windows profile or else go through the convoluted process of getting the GPO admins to undo the group policy for one user to unhide the tab, have the help
    desk reset the browser for the user and then have the GPO admins reapply the original policy.

    You can try the following script
    Reset Internet Explorer all Setting to default using PowerShell Script
    http://gallery.technet.microsoft.com/scriptcenter/Reset-Internet-Explorer-20f838e7
    but this script still launches an interactive interface, you can ask in this form to improve the script to achieve an totally unattended process.
    The Official Scripting Guys Forum!
    http://social.technet.microsoft.com/Forums/scriptcenter/en-US/home?forum=ITCG
    You can create a task schedule to trigger the process. When computer starts or
     IE open , the script launches itself automatically.
    Schedule a task
    http://windows.microsoft.com/en-au/windows/schedule-task#1TC=windows-7
    Regards
    Yolanda
    TechNet Community Support

  • Pop-up screen does not appear for inspection point- In-process inspection

    Hi,
    We havs set up inspection points( time-based) in the master recipe. In that inspection point , we have defined date,time and inspector name as 3 fields to be maintained , before the results recording can start for each characteristic.
    Even though the inepction point is assigned in the header QM data of recipe , system does not give the pop-up at all to record the date , time and inspector's name.
    Please let me know what settings might be missing to get this pop-up screen to record the inspection date,time and inspector's name.
    Regards,
    Manohar

    The Sampling procedure with free inspection points radio button is chosen. However, we are not getting the pop-up screen of QE11.
    What we are trying to get in QA32 , is when we click on "results recording" push button , we want to get QE11 screen to pop-up so that the inspector's name and date and time are recorded , before the results recording screen comes.
    Please suggest whether this is a personal setting or master data setting or config setting or some exit to be used.
    Regards,
    Manohar

  • Custom exit or badi for changing the user fields in operation of process order

    Hi all
        I want to find a exit or badi to set default value to the user fields in operation of process order when COR1.
        I have tried exit 'PPCO0001', but this exit is call after commit work, so I can not change any thing
        I also tried to use badi 'workorder_update', 'before_update', but all parameters in this BADI are importing, can't be changed, I've tried to change it and then program dump.
        Do you have any solution for this question?
    Thanks

    Do a Implicit Enhancement at the PBO of this subscreen.

  • Change default security settings for new Discoverer users? How?

    Hello, using Discoverer 10g with SSO integration.
    I've created two roles and create in advance users in the DB user, granting them
    one of the two roles. The two roles privileges for Discoverer are already configured.
    This way, when I create the user in the DB before launching Disco, granting the user one or the other role, I should be all set about what the user can or cannot do on Discoverer (Plus).
    So far the theory :)
    The problem is that the full permission given by Discoverer to each new user override the role settings, so each new user can do everything (instead one of the roles forbids saving and sharing, for example).
    I have to go to Disco Admin and uncheck the "Plus/Viewer" checkbox for the user to make roles actually work as expected.
    How can I set Discoverer user default as "Cannot do anything" on Plus/Viewer so that roles apply without further admin intervention?
    Thanks
    Mario

    Thanks a lot Rod.
    The problem here is we need to allow portal users the ability to access Discoverer Plus without using Disco Admin: once a user is registered in the SSO, he should be able to connect successfully to Discoverer.
    So we need creating user privileges on behalf of Disco Admin.
    Tough job, but it seems it ca be done.
    Regards,
    Mario

  • Runtime error for Inspection Point Results Recording

    Hi,
    I am changing the already done Results Recording for using already used Inspection Point.
    I am getting the runtime error. Anybody came across such error?
    Regards
    Ramakanth

    Hi,
    In the in-process inspection I am using Inspection Points. Initially I have done Results Recording once with quantities.
    And then again I wanted to change the quantities for the same Inspection Point. So, I went to Results Recording for same Inspection Point and changed the quantities and saving. At this event I am getting Runtime error.
    I  have even deactivated one BADI INSPECTIONLOT_UPDATE and tried again. Even then I am getting same error.
    Ultimately my requirement is this:
    My client wants UD at operation level. They want only quantity which is accepted in Results Recording to be moved to the next operation. In the operation level confirmation the system should only accept the quantity which is accepted in Results Recording.
    Any suggestion in this regard.
    Thanks
    Ramakanth

  • Regular Expression for floating point numeric field

    Hi,
    the requirements for the field are as follows:
    - floating point numeric field 7 digits in length
    - the field must contain a decimal (dot) and either one, two or three digits to the right of the decimal
    - (leading zeroes are required if needed to fill up the 7 characters)
    My example shown below does not check for the length of 7 characters:
    public static void main(String[] args) {
        String str = "04100.0";
        System.out.println(str);
        Pattern f_1To7 = Pattern.compile("^([0-9]*\\.[0-9]{1,3})$");
        Matcher matcher = f_1To7.matcher(str);
        if (matcher.find()) {
            // yes, we've found something
            System.out.println("We matched the pattern!");
        } else {
            System.out.println("Better luck next time!");
    }When changing the pattern to
    ^([0-9]*\\.[0-9]{1,3}){7}$the whole expression will be repeated 7 times - but I would like to have to whole String to be 7 characters long.
    Here are some examples for the field:
    050.500 or 04100.0Thanks a lot and best regards,
    - Stephan

    Jackler wrote:
    Perhaps I did not express clearly enough. My problem is not a java issue - what I need is a regular expression (pattern) suiting my requirements:
    -floating point numeric field 7 digits in length
    -contains a decimal and either one, two or three digits to the right of the decimal
    ...Assuming that you are going to use Java*, you could use a lookahead at the start of your regex:
    "^(?=\\d{4,6}\\.\\d{1,3}$).{8}$"Meaning:
    ^             # match the start of the string
    (?=           #
      \d{4,6}     #   ensure that there are between 4 and 6 digits...
      \.          #   followed by a DOT...
      \d{1,3}     #   followed by 1 to 3 digits
    .{8}$         # match exactly 8 characters directly followed by the end of the string* or some other language that has look-ahead support (most PCRE implementations have them)

  • Different MICs for Inspection points

    How can you do if you like to have different inspection characteristics for different (freely-defined) inspection points. E.g. if you take a sampl (sampl 1) by using freely-defined inspection ponits and test 5 differnt MICs, then 10 minutes later you pick another sample (sampl 2) out of your production and there you only need to inspect 3 MICs. How can you set this up?

    Hi ,
    Better create different operation in routing & then assign different MIC s to different to operation .I think that will be better option
    ( Aster 5 mins you are going to check only 2 MIC then that will be 1 opoeration ,Then after 10 mins you are checking 5 MICs then that will be 2 nd operation like wise you can check & take result of different sample at different stages.
    Regards
    SANIL

  • Defect recording for inspection points

    Hi,
    My client having requirement of recording the defects every hour.in standard SAP defects recording with respect to inspection point is not possible.Is there any other way to do this.
    Regards,
    S.P.Selvathangam

    Hi,
    It is not a problem follow the below step.
    1). Go QM01 enter notification type Q3 (Manual Defect and Notification creation) and press enter.
    2). After enter system will raise the one pop up screen here enter the production order as well as operation number and press enter.
    3), After that it will open defect with notification screen here you can enter defect qty, defect code reason, causes etc and save.
    For any query revert.
    Thanks & Regards,
    S.Babusingh

  • BAPI for inspection point

    Hi,
    I am trying to find BAPI through which i want to do inspection point and result recording. If anyone has done then let me know which bapi is suitable and provide what are all data's need to pass.
    Regards / US

    Hi,
    Check the documentation for function BAPI_INSPOPER_RECORDRESULTS. That gives a pretty detailed description of all the import requirements
    Functionality
    You can use this method to confirm the result of a quality inspection for an inspection operation or inspection point. The following functions are supported:
    Creating an inspection point 
    Closing an inspection point 
    Changing inspection point data 
    Recording inspection results at characteristic level (summarized) 
    Recording inspection results at sample level (summarized) 
    Recording inspection results at single value level
    You define within an inspection operation whether you work with or without inspection points. In accordance with this specification, the parameter INSPPOINTDATA is required or optional.
    Regards,
    John

  • Change Word & Excel Settings for ALL FUTURE USERS

    We have a computer lab in which each student has his/her own login.  They use Word and Excel 2010 in the classroom.  There are several settings that the teacher likes to set for his students, but currently he must log in to all 120 of the student
    accounts and set the settings.  A summary of those settings is:
    Change default font size to 12
    Change paragraph to single spacing with no space after text
    Add items to the quick launch bar at the top of the screen
    I'm working on setting up a new computer for imaging for him.  Is there any way for me to make these setting changes globally, so that each student gets the correct settings when they log on for the first time?

    Hi,
    For Word, the custom font is customized via the Normal.dotm template, located at %APPDATA%\Microsoft\Templates. Navigate to this location, right click on the template and choose Open. On the Home tab, in the Font group select the font of your choice, then
    right click on the editing area, click Paragraph and select single spacing and other settings you need to configure, click OK then save the file.
    For Excel, the font is customized via a registry key:
    Important
    This section, method, or task contains steps that tell you how to modify the registry. However, serious problems might occur if you modify the registry incorrectly. Therefore, make sure that you follow these steps carefully. For added protection, back up the
    registry before you modify it. Then, you can restore the registry if a problem occurs. For more information about how to back up and restore the registry,
    http://windows.microsoft.com/en-US/windows7/Back-up-the-registry
    HKEY_CURRENT_USER\Software\Microsoft\Office\14.0\Excel\Options
    Name: Font
    Type: REG_SZ
    Value: Arial,12
    After we define the Word template and changed the Excel Font registry key, we need to deploy it globally via an MSP file:
    1. Create a customization .msp file using the Office Customization Tool: drag and drop the
    setup.exe of the Office installation source in the Run box, and pass it the switch
    /admin
    2. This will open OCT (Office Customization Tool)
    3. Select the first option: Create a new Setup customization file for the following product and click OK
    4. We are now ready to add all our files into then MSP
    5. Under Additional Content – click Add Files to add here the template for Word (Normal.dotm). In the
    File Destination Path dialog box, in the Destination path on the user's computer list, select
    %AppData\Microsoft\Templates, and then click OK
    6. Under Additional Content - click Remove files, and then click
    Add. In the File Path dialog box, under
    Path and file name of file to be deleted, enter %AppData%\Microsoft\Templates\Normal.dotm, and then click
    OK. (This will remove any Normal.dotm file from the users’ computers that is from a previous installation of Word.)
    7. In the console tree, click Add registry entries, and then click
    Add. Follow the path I mentioned for Excel: HKEY_CURRENT_USER\Software\Microsoft\Office\14.0\Excel\Options, type in the information and click
    OK to save.
    8. In the console tree, click Remove registry entries, and then click
    Add. Type in the registry key information above and click
    OK to save. This will remove the previous font setting for Excel.
    We have now finished creating the customization file. You can save it from
    File – Save as – Name.msp
    We are now ready to create the start-up script and add it to the GPO that will deploy these settings to the whole organization.
    To create the .bat file that will be used in the start-up script, please open Notepad and use the following text:
    setlocal
    reg query HKEY_CLASSES_ROOT\Installer\Patches\9EA4D5478DD17EE45B1A1E670AC471BC
    if %errorlevel%==1 (goto Patches) else (goto End)
    REM If 1
    returned, the patch is not installed. Install the patch here.
    :Patches
    "%windir%\system32\msiexec.exe" /p \\server\shared_folder\Name.msp /qn
    REM If 0 or other was returned, the patch is already installed. Do nothing.
    :End
    Endlocal
    Please NOTE that you need to change the
    \\server\shared_folder to point to the correct path and MSP file in your environment.
    Save the Notepad file as Name.bat in the same shared location (\\server\shared_folder)
    On the Domain Controller create a new Policy and assign it to the desired
    Organizational Unit. Edit the policy and go under:
    User Configuration – Windows Settings –
    Scripts (Logon/Logoff)
    Double click Logon – click Add
    Under Script name please type the location and the name of the .bat file we created earlier (please use UNC path and not a drive letter)
    For your reference:
    Office 2010 – Deploying custom fonts across all applications
    http://blogs.technet.com/b/emeaoffice/archive/2012/12/12/office-2010-deploying-custom-fonts-across-all-applications.aspx
    Set the default font and page margins in Office Word 2007 for a group of users(Also works for Word 2010)
    http://technet.microsoft.com/en-us/library/dd631810(office.12).aspx
    By the quick launch bar, do you mean the Quick Access Toolbar? If so, when you customize the it in a particular application, Office 2010 creates an *.officeUI file for that application that contains the customization XML. With this understanding, you can
    do one of the following:
    •Modify an existing *.officeUI file with the desired customizations by updating the XML code.
    •Create the desired customizations by using the Customization dialog in the Microsoft Office application, apply the customizations, and then browse to the *.officeUI file.
    Please note we need to customize the Quick Access Toolbar in each application.
    Detailed steps to deploy the Quick Access Toolbar can be found in this MSDN article below:
    http://msdn.microsoft.com/en-us/library/ee704589(office.14).aspx
    I hope the information is helpful.
    Regards,
    Melon Chen
    TechNet Community Support
    It's recommended to download and install
    Configuration Analyzer Tool (OffCAT), which is developed by Microsoft Support teams. Once the tool is installed, you can run it at any time to scan for hundreds of known issues in Office
    programs.

  • What is Make System Settings for Measuring Points and Measurement Documents

    Dear PM Guru's,
    i have doubht on the above customization section? in which situations we can activate or create new one ? whats its importance, how its impacts on our business scenarios. please suggest me and help me. Now i am in realization phase i am not observed much more difference with this check box .
    i hope i will get the answer very soonly, and thanks to all of the PM gurus

    Hi,
    << Moderator message - Cut and paste response from http://www.consolut.com/en/s/sap-ides-access/d/s/doc/YY-OLI0IMRCCUST removed. Plagiarism is not allowed in SCN >>
    Regrds
    Jitender
    Edited by: Rob Burbank on Jun 6, 2011 10:53 AM

  • Different inspection point field combination for each operation ?

    Hi
    I see that i can choose inspection point user field combination in the inspection plan header.
    But what i need is to define different combinations for each operation,
    Is this possible?
    If not do u have any other suggestions?
    Thanks,
    Alper,

    Dear Alper,
    I just meant in config .SPRO > Quality Management > Quality Planning >Inspection Planning >Define Identifier for Inspection Points
    you can make use of all the identification field for your purpose ( Text length 18, text length 10, Number length 10, number length 3 )
    operation wise what is needed to enter you make use of it
    Only a suggestion
    Regards
    gajesh

  • Inspection Point table

    Dear All,
    we are in the process of automating the results recording process using a Z program. For the results recording i have used Inspection points. What i mainly want to do is from several characteristics, Initially record results for one inspection characteristic and later record results for a different inspection characteristic. In the STD  SAP this allows to do. What i want to know is since i use the Inspection points, what are the tables that will be used?
    Thanks and Regards,
    DTD

    Hi
    Hope these details will help you
    QALS Inspection lot record
    QAPP Inspection point
    TQ79 Table with inspection point/user field combinations
    TQ79T Key words for inspeciton point user fields
    QAMR Characteristic results during inspection processing 
    QAMV Characteristic specifications for inspection processing 
    Regards
    Charith

Maybe you are looking for

  • PDF portfolio works in what versions?

    How do I know what versions or Acrobat or Reader my PDF portfolio will work in? Will it work in reader?

  • ABAP code for BI 7.0 transformations start routine

    Hi all, I am trying to update data from DSO1 (Source1: transaction data) to Infocube(TARGET) In the transformations Start routine, I have to read DSO2(Source2: Master data) for some fields. DSO1 has CUSTOMER as part of key DSO2 has CUSTOMER (key) and

  • File not found during installation (WinXP)

    Well, I downloaded Oracle 11g for Windows (32 bit) from http://www.oracle.com/technetwork/database/enterprise-edition/downloads/index.html, and, basically, after having had some trouble configuring a new database, I selected the option to (simply) in

  • Post complete logs/output/versions/error messages

    When you have an issue, post the ENTIRE output or log. Information is crucial to being able to solve any problem. I've seen threads go for pages and all someone needed to do was ask for a log file or simple command output. Don't do this It doesnt wor

  • Foxit Reader is not opening pdf files online