Simulation model which call functions in an other dll...

I have a C simulation model that I implement like NI Model Framework template (NI_VStand_Model_Framework_Guide.pdf ). If I use this simple model I can deploy on my PXI. But I must call functions which are in an other dll. When I call functions in other DLL I can't deploy because Veristand specify that the model is not compatible.
NI VeriStand: The specified compiled model is not compatible with NI VeriStand.
=========================
NI VeriStand: NI VeriStand Engine.lvlib:VeriStand Engine Wrapper (RT).vi >> NI VeriStand Engine.lvlib:VeriStand Engine.vi >> NI VeriStand Engine.lvlib:VeriStand Engine State Machine.vi >> Model Execution.lvlib:Initialize Model Loop Data.vi >> SIT Model API.lvlib:Initialize Model.vi >> SIT Model API.lvlib:Load Model DLL.vi
<append>=========================
NI VeriStand: Failed to load c:\ni-rt\NIVeriStand\Models\LD1_T1.dll
If I use DLL Checker there is no bad import.  How to add a simulation model in veristand which call function in an other DLL?

Thank you for your answer.
I know how to import a dll in veristand. My Dll  is LD1_T1. I can import it in Veristand without error. But this DLL depends of an other dll (addition.dll) as you can see in the print screen.
When I try to deploy to my PXI I have an error message of compatibility. 
NI VeriStand: The specified compiled model is not compatible with NI VeriStand.
=========================
NI VeriStand: NI VeriStand Engine.lvlib:VeriStand Engine Wrapper (RT).vi >> NI VeriStand Engine.lvlib:VeriStand Engine.vi >> NI VeriStand Engine.lvlib:VeriStand Engine State Machine.vi >> Model Execution.lvlib:Initialize Model Loop Data.vi >> SIT Model API.lvlib:Initialize Model.vi >> SIT Model API.lvlib:Load Model DLL.vi
<append>=========================
NI VeriStand: Failed to load c:\ni-rt\NIVeriStand\Models\LD1_T1.dll
For LD1_T1.dll I have use NI Model Framework template (NI_VStand_Model_Framework_Guide.pdf ).
If I check my Dll with dll checker it's ok but I can't deploy. 
Please somebody have an idee to deploy my model ?

Similar Messages

  • Calling function wsastartup() of wsock32 DLL

    Could someone tell me how to use the function "wsastartup()" of wsock32.dll to initial a network connection?
    Here is the definition of the wsastartup() function:
    int WSAStartup(
    __in WORD wVersionRequested,
    __out LPWSADATA lpWSAData
    Parameters
    wVersionRequested [in]
    The highest version of Windows Sockets specification that the caller can use.
    The high-order byte specifies the minor version number; the low-order byte specifies the major version number.
    lpWSAData[out]
    A pointer to the WSADATA data structure that is to receive details of the Windows Sockets implementation.
    Return Value
    If successful, the WSAStartup function returns zero. Otherwise, it returns one of the error codes listed below.
    For more wsastartup() detail, please visiti
    http://msdn.microsoft.com/en-us/library/ms742213%28VS.85%29.aspx
    I've tried many times and that cause labview to crash.
    Please give an example, thanks.
    Devin

    smercurio_fc wrote:
    The LabVIEW network functions don't operate at that low of a level. Based on what you are looking to get, it seems to me that a third-party software solution would be far easier to use than to try to call Windows API functions from LabVIEW. Have you tried Google to find such software?
    I would say it depends what network throughput numbers the OP wants to calculate. If sending out data through TCP/IP to some remote location and calculating the maximum or average possible throughput from that it could certainly be done in native LabVIEW. One thing to watch out here is that LabVIEW uses the network socket API in a specific way that is for instance not suited for high througput server applications. So the numbers calculated in such a way would be meaningful in comparison with each other but not necessarely a good indication what a high througput server application could achieve using overlapped and/or I/O Completion Ports Winsock calls.
    If it is about generic data about the winsock usage then there are IPHLP.DLL APIs to get at some of that data and some is available through the registry in the Performance data section.
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Call function defined in other class

    Hi..
    I am new to Java programing .
    I want to know how to call a function defined in second class from first class.
    Please help me.

    Hi..
    If both the classes are in same package, and the function is not private, u can call the function by using an object of the second class. If they r in separate packages, u have to import the package in which the second class is. In any case, public methods are allowed and private methods are not allowed to be invoked.
    Hope this info may help u..

  • Calling function between subprojects and DLL in WINCE7

    We inherit a project develop using Platform Builder with WINCE7 and Visual Studio 2008. The project has a BSP, 5 sub-projects and a DLL. The problem is that when we add a function to the DLL Data Manager and try to call the new function from any of the subproject
    using an Data Manager object that is currently used in the subproject to call other functions on the Data Manager DLL, we get the following error:"Error 107 Configuration_Setting_Mapper.obj : error LNK2019: unresolved external symbol "public: void
    __cdecl Data_Manager::Configuration_Manager::Set_Default_TEST(void)" (?Set_Default_TEST@Configuration_Manager@Data_Manager@@QAAXXZ) referenced in function "public: bool __cdecl Configuration_Setting_Mapper::Set_UserName_Default(void)" (?Set_UserName_Default@Configuration_Setting_Mapper@@QAA_NXZ)
    Same error is received when we try to change the return type of any of the functions in the Data Manager DLL. Do we have to set a link between the Data Manager and the subproject? What could be missing?

    So the import library for the DLL needs to be updated (with the new function which you are exporting). Otherwise, it's as though you installed a new version of desktop Windows with new capabilities but used the old API libraries; your code won't link because
    the API library *you are using* doesn't match the DLL you want to call.
    Since your code compiles, you're obviously using the new header file(s).
    So, what to do? Without seeing the projects and understanding how the original structure was intended to work, I'm not sure we can say. You may be linking with a library in the SDK folder but not regenerating that library when the DLL changes, or you may
    not be generating a new import library when rebuilding the DLL.
    Paul T.

  • Call function module in new task

    I need to call a function module starting new task but the problem is that it has inporting parameters also. Please help me in doing this. Points will be rewarded.

    Look at the ABAP keywords RECEIVE RESULTS FROM FUNCTION.  This is where you can get the results from the CALL FUNCTION MODULE... NEW TASK...
    It's all in the ABAP help for CALL FUNCTION MODULE.
    matt

  • Call function maximum print.

    Hi all.
    I have print proble. if  sombody  know that , please let me know.
    if  the  number of itab is  '400',  when 300 times print is not printing.  logic like below.
    loop at itab.
    call function 'OPEN_FORM'
        exporting
          device  = 'PRINTER'
          dialog  = ' '
          form    = 'Z_CPS_OUTBOX'
          options = option
        exceptions
          others  = 9.
      if sy-subrc <> 0.
        exit.
      endif.
      call function 'WRITE_FORM'
        exporting
          element  = l_element
          function = 'SET'
          type     = 'BODY'
          window   = 'MAIN'
        exceptions
          others   = 8.
      call function 'WRITE_FORM'
        exporting
          element  = l_element
          function = 'SET'
          type     = 'BODY'
          window   = 'BARCODE'
        exceptions
          others   = 8.
      call function 'CLOSE_FORM'
        exceptions
          others = 4.
      if sy-subrc <> 0.
        exit.
      endif.
    endloop.

    can u jot down ur exact requirement..
    why r u opening and closing the form inside the loop?
    u could have done this:
    openform...
    loop at itab.
    writeform...
    endloop.
    closeform...

  • Calling RFC function module in other SAP system...

    Hi,
    I have a report on one SAP system and a function module on other system. The function module is RFC enabled. How can I call this RFC enabled function module from other SAP system in the report which is different SAP ?
    system.
    Thanks.
    Regards,
    Rajesh.

    call the function module in orginal system in se38 ,copy the function module ,paste the function module in other system,and maintain destination here ,otherwise you will get short dump.
    here detination should be SM59 destination,this is case sensitive.
    Reward Points if it is helpful
    Thanks
    Seshu

  • Which is the best way for a called function to identify caller class name.

    Which is the best way for a called function to identify the caller class name .
    1)Using sun.reflect.Reflection from called function
                    Class caller = Reflection.getCallerClass(2);
                    System.out.println("Caller Class Name ::"+caller.getName());2) Analyzing current threads stack trace from called function
                    StackTraceElement[] stElements=Thread.currentThread().getStackTrace();
                    System.out.println("Caller Class Name ::"+stElements[3].getClassName());Is there any alternate ways to achieve the same .Which is the best way ?
    Called function doesn’t have any arguments, I don’t want t pass any arguments from caller function to called function.
    Plz help.
    With kind regards
    Paul

    798185 wrote:
    Which is the best way for a called function to identify the caller class name .
    Is there any alternate ways to achieve the same.SecurityManager
        // 0 is the anonymous SecurityManager class
        // 1 is this class (also works in static context)
        // 2 is calling class
        static Class getClass(int i) {
            return new SecurityManager() {
                protected Class[] getClassContext() {
                    return super.getClassContext();
            }.getClassContext();

  • User Exit for Variable which calls to a Function Module is NOT working ???

    Hi all,
        I have a created a variable 'ZNBUSDAY' with Processing Type 'Customer Exit' on 0SCL_DELDAT  (Date). The query is on 0PUR_C04 and passing 0SCL_DELDAT  to Function Module  Z_WORKDAY to get the Next Business Day by using the company Calendar(30). The following code is NOT working and what is WRONG with it, PLEASE? The FM is working FINE.
    DATA: wa_calendar(2) TYPE c value '30',
          wa_znbusday    like sy-datum,
          0scl_deldat    like sy-datum,
          p_days         TYPE i value 1.
    case i_vnam.
       when 'ZNBUSDAY'.
       CLEAR wa_znbusday.
       CALL FUNCTION 'Z_WORKDAY'
         EXPORTING
         CURR_DATE        = 0scl_deldat
         NUMBER_DAYS      = p_days
         CALENDAR         = wa_calendar
       IMPORTING
         WORK_DAY         = wa_znbusday
         l_s_range-low  = wa_znbusday.
         l_s_range-opt  = 'EQ'.
         l_s_range-sign = 'I'.
         append l_s_range to e_t_range.
    endcase.
    Thanks,
    Venkat.

    Hi Venkat,
    Looks like you're only assigning type sy-datum to 0scl_deldat but not the actual value. Try the following:
    DATA: wa_calendar(2) TYPE c value '30',
          wa_znbusday    like sy-datum,
          0scl_deldat    like sy-datum,
          p_days         TYPE i value 1.
    case i_vnam.
       when 'ZNBUSDAY'.
       CLEAR wa_znbusday.
       0scl_deldat = sy-datum.
       CALL FUNCTION 'Z_WORKDAY'
         EXPORTING
         CURR_DATE        = 0scl_deldat
         NUMBER_DAYS      = p_days
         CALENDAR         = wa_calendar
       IMPORTING
         WORK_DAY         = wa_znbusday
         l_s_range-low  = wa_znbusday.
         l_s_range-opt  = 'EQ'.
         l_s_range-sign = 'I'.
         append l_s_range to e_t_range.
    endcase.
    Kind regards,
    Alex

  • How to call function which return and out

    My function specifcation is
    FUNCTION GetGoogleScholarActivation (
    pi_clnt_id IN google_scholar_status.clnt_id%TYPE,
    pi_status_type IN ci_status_type_tab_type,
    po_status OUT ci_status_tab_type,
    po_date OUT ci_date_tab_type
    RETURN NUMBER ;
    where type is
    TYPE ci_status_type_tab_type IS TABLE OF VARCHAR2 (1) INDEX BY BINARY_INTEGER;
    TYPE ci_status_tab_type IS TABLE OF VARCHAR2 (10) INDEX BY BINARY_INTEGER;
    TYPE ci_date_tab_type IS TABLE OF VARCHAR2 (8) INDEX BY BINARY_INTEGER;
    I am trying to call function in SQL PLUS for testing as
    declare
    var number ( 10);
    TYPE p_st1 IS TABLE OF VARCHAR2 (1) INDEX BY BINARY_INTEGER;
    p_st p_st1 ;
    type p_status1 IS TABLE OF VARCHAR2 (1) INDEX BY BINARY_INTEGER;
    p_status p_status1 ;
    TYPE p_date1 IS TABLE OF VARCHAR2 (8) INDEX BY BINARY_INTEGER;
    p_date p_date1 ;
    Begin
    p_st(0) := 'A';
    var := PQDKGOSH.GetGoogleScholarActivation(11920 , p_st, p_status ,p_date );
    dbms_output.put_line ('Activation_status '|| p_status(0) );
    dbms_output.put_line ('Activation_date '|| p_date(0) );
    dbms_output.put_line ('Retun Value'|| var );
    End;
    but getting error PLS-00306: wrong number or types of arguments in call to
    'GETGOOGLESCHOLARACTIVATION'
    so how to test from SQL Plus

    HI
    I tried to execute below like this
    declare
    var number ( 10);
    p_st ci_status_type_tab_type ;
    p_status ci_status_tab_type;
    p_date ci_date_tab_type;
    Begin
    p_st(0) := 'A';
    var := PQDKGOSH.GetGoogleScholarActivation(11920 , p_st, p_status ,p_date );
    dbms_output.put_line ('Activation_status '|| p_status(0) );
    dbms_output.put_line ('Activation_date '|| p_date(0) );
    dbms_output.put_line ('Retun Value'|| var );
    End;
    still iget error
    PLS-00201: identifier 'CI_STATUS_TYPE_TAB_TYPE' must be declared
    becuse this declareation i did in package specification .
    and i am trying to execute the function .

  • Why Service Call and why not call Function module Directly in WD ABAP

    Hi,
    I have created a Webdynpro applications and the logic requires calling avrious Function modules.
    Do I need to create Service Call for each Function module or call them directly.
    It would be great if you can suggest me under what cases I need to opt for Service call
    For example, if I use 'RP_CALC_DATE_IN_INTERVAL', do I need to use Service call or call function module directly.
    Note: I have searched forums but could not get the correct answer which I want
    Thanks!

    The Service Call is really meant to be a wizard/time saver.  It has the advantage that it can generate matching context nodes/attributes for the interface of the Function Module you are calling. However everything that the service call does can also be created by hand.
    Personally I'm not a fan of what the service call wizard generates.  Its good as a time saver or for beginners, but I find I prefer to touch up the code it generates anyway. I much prefer to create a nice reusable model class with its own unit test and then consume this model class (with the service call wizard) from WD.  This model class might contain one or more function module calls depending upon what logic I need to access.

  • Facing issue with tRFC (CALL FUNCTION in BACKGROUND TASK DESTINATION

    In transcation CJ20N there is aBADI call ZCL_IM_CL_IM_PROJ_UPDATE in which there is a method
    IF_EX_PROJECTDEF_UPDATE~AT_SAVE.  My requirement is that when the status of the project is changed and saved then after the SAVE some actions are to be performed (BDC for transcation CJ30 & CJ9FS are to be called).
    Since this method is called AT SAVE and i need to call the bdc after the comit (of SAVE) is done. So I have made a RFC FM in which I am calling the bdc. and then calling the FM as
    CALL FUNCTION <FM> in BACKGROUND TASK DESTINATION <sy-sysid>.
    For the txn. CJ9FS bdc this method is working fine and bdc is called after SAVE but for txn. CJ30, at times,the bdc  is not working though if I run the BDC FM seperately using SE37 then its working fine.
    Can any body guide me where I am going wrong.

    The scenario works fine for me. The issue was unable to create a proper test condition in the RFC.
    CALL FUNCTION 'ZMY_RFCASYNC'
       IN BACKGROUND TASK
       EXPORTING...
       TABLES...
       EXCEPTIONS...
    Simulated error condition in 'ZMY_RFCASYNC'
    and got entry in SM58 by simply making an exception. 
    Thank you all.

  • Iphone 3gs Video calling function

    How do I use the video calling function on the 3GS I was told by 02 customer service, that it's below the "call" button under options???????....how do I do this, obviously it needs to be a 3G phone receiving the call, and one that enables video calling....

    I don't know about the slacking part. The iPhone's introduction got many cell phone manufacturers off their collective duffs - away from putting out pretty much the same old stuff year after year without seeing significant improvements. Phones in the smart phone category were primarily targeted at the enterprise or business market prior to the iPhone. Sales of phones in the smart phone category to consumers is on a significant rise due to the iPhone, and how many iPhone "killers" have we seen since? A bunch, which is a good thing.
    Apple doesn't manufacture different iPhone models. There is one model at a time with the only difference being storage capacity or a black or white backing. Video calling may be used heavily in parts of Europe with a significant number of cell phones sold with the capability, but not so in the U.S. - not yet anyway.
    I venture to say we will see this capability with the iPhone at some point. Maybe after LTE (4G) networks get rolled out in many parts of the world. The two largest carriers in the U.S. - Verizon and AT&T are in the process of rolling out an LTE (4G) network which won't be in place extensively for another 2 years or so.

  • PLL simulation model in AWRDE

    Hi,
    Below is a question I got from one of our AWR customers. 
    "Can we generate the simulation model of a PLL Synthesizer IC from its datasheet and/or the PLL available in Elements/Systems/PLL of MWO ?
    Are there simulation models available in MWO for Analog Devices PLL ICs ?"
    My understanding is that if the manufacturer provides the SPICE model of a PLL IC it can definitely be used ina  MWO simulation but I doubt if any manufacturer will. In such a case how feasible is it to build a SPICE model of the PLL from the specifications in the datasheet ? Secondly, since a PLL is a control loop wouldn't it be difficult to close the loop in SPICE programming and have the model converge on a solution in a simulation ? Also, will SPICE models of PLL's simulate fast when there are a lot of extra poles and zeroes for the transfer function ? 
    Anyhow, can someone kindly tell me what I can inform my customer about the PLL question ? 
    Thank you very much

    HI Jake,
        The question becomes what are they trying to do with a PLL model in their simulation?  Do they want to include the phase noise out of a PLL into a mixer simulation or amplifier simulation?  
    You can do system level simulation of a PLL but that would be specifying each block's system behavior.    You can search for PLL examples in our help to find these VSS examples.    If you could find a spice model, you could simulate that, but PLLs are definitely a transiety type of simulation and they can take a long time to settle out.  So unless you are trying to simualte the settling time of a PLL, I go back to the original questin of what problem the customer is trying to solve?   This would also depend on the vendor providing the model, which it sounds like they do not.   
    The most basic level answer is that the Vendor would need to provide the models available for Analog Devices PLL ICs.  
    Thanks,
    AWR Support

  • How to do job_submit on a program which calls a custom FM?

    Hi all,
    I am doing a job_open, job_submit and job_close to submit a FM in background.
    Now, how do I do a job_submit for a program which contains the FM that doing the real processing?
    Details:
    Program ZNSC_WRAP_RMD contains call function "YXAPY_REVIEW_MASTER_DATA'
    CALL FUNCTION 'YXAPY_REVIEW_MASTER_DATA'
        EXPORTING
          i_pay_area                        = ' '
        I_CHECK_OPTION                    =
        I_GUI_ENABLE                      = ' '
        I_PERNR                           =
       IMPORTING
        E_LOCK_EMP_TBL_ERROR              =
        E_TIME_RECON_TBL                  =
        E_UNAPPROVED_TIME_TBL_ERROR       =
        E_WAGE_TYPE_TBL                   =
        E_MISSING_INFO_TBL_ERROR          =
         E_RETURN                          = e_return
        tables
          t_return                          = t_return
    Any idea?

    A job running in the background can not and should not use the frontend resources example GUI.
    In your function module I see a parameter * I_GUI_ENABLE = ' '. Check it's usage and make sure GUI (and frontend processes) are disabled for the job to run in the back ground.
    Any direct or indirect use of classes or FM calls which require frontend cannot execute in background as a job.
    Regards,
    Aabhas

Maybe you are looking for