Special proc key parameter's in spro

Plese Give me navigation for  the special proc key parameter's setting Txn Or Navigation

ThanQ for your immediate answer
I want to plan in plant 1001 and Produce in plant 1002 for which i have made settings in special proc key parameter's of spro for  plant1001 alt plant as 1002 and made necessary changes in material master data (spl proc key as 40 in mrp-2 view) But for my requirement, issuing plant should be plant 1002 only. Please suggest any other settings required for planning in one plant and producing in another plant.

Similar Messages

  • Special Proc KEy 30 in Material master in MRP 2

    respective guru's
    Pls explaing about the special proc key 30 (Sub contract)in material master of MRP2  and how to use  for external processing .

    Hi,
    In fyou want to get a material from a sub-contractor you will have to use spl proc key as 30.
    Suppose you watn to receive a HALB matl from contractor use key 30.
    When you run mrp, a planned order will be created.
    Convert this in to pur order.
    use me2o or mb1b & send the raw material to the contractor thro 541 mvnt.
    Then use migo 101 mvmnt & receive HALB.
    You have to use 30 only if you need to get the full material from the contractor.
    Suppose you have 3 operation for the halb & you want the contractor to do only the 20th operation then you go for ext processing. For this give control key pp02 in the opreation 20 in the routing.
    Regards,
    Senthilkumar SD

  • MB21 - Reservation in reference to a BOM - Special procurement key

    Hello,
    I want to create a manual material reservation against a WBS element in reference to a BOM which uses a special procurement key at component level. This special procurement 70 uses the following configuration points:
    -  Procurement type: External procurement
    -  Withdrawn alternate plant indicator: checked
    -  Issuing plant: 0410
    When creating the reservation with MB21, the BOM referenced is created in plant 0100. I was expecting component reservations created from plant 0410 but not. All reservations created are from plant 0100. Any ideas why the special procurement key is NOT taken into account in this scenario using MB21?
    On the other hand, I successfully tested this procurement key within a PM order; all component reservations created are from plant 0410, as expected. 
    Thanks for your help.
    Christian

    Hi Christian,
    Happy to see your posting. Good that your work is going ahead.
    But, I think your initial post was not checking "How to..." but was "Why it is not possible in manual MB21 when possible with PM order linked scenario?". Right? For "How to.." the SAP feedback is OK to make use of user exit which one can anyway decide (without SAP involvement) to carry out his/her work.
    May I know specific--Has SAP suggested a SAP Note wherein use of User Exit is recommended? or a simple reply to your SOS message as a recommended option?
    The reason behind making this point is How it can be considered as standard behaviour when on one side - BOM explosion wrt special proc key and creating reservation/requisition through PM order scenario goes successful and on the other hand not possible through manual MB21?
    Bye..

  • Cross company code Stock transfer - Special procurement Key

    Hi,
    Please clear my following doubts...
    1. We have two company codes, Company code: A1 having a Plant: AP1, Company code B1- Pant BP1,
    Finished goods sold from the plant AP1 are purchased from the plant BP1, so is there is any possibility to create a special procurement key having BP1 as the delivering plant and assign the key in AP1 materials.
    2. Can i combine the two plants AP1 and BP1 for total online planning (MD01) by creating a scope of planning indicator? and run a single MRP run for both plants at a time...
    Please clarify...
    Thanks,
    JK

    JK,
    I dont think Scope Planning is problem. You can create Scope of planning combining multiple plants, use transaction OM0E.
    I doubt on Special procurement key option for STO across cross company codes, as the special setting needed in that case would be that Plant as to be created as Vendor / Customer. I would suggest to post this to MM forum for further response on this.
    Regards,
    Prasobh

  • Special procurement Key in APO

    How do I define in APO the special procurement key relationships between plants within the company or consignment/ subcontracting, just want to maintain the same relationship as in R/3. I know you answered about special procurement type U: stock transfer which I got it, could you please explain how I maintain the above Sp. procurement keys in APO.
    Thanks Mono
    Harish's reply:
    As far as i know you cant maintain Spl procurement keys in APO. This is used as an indicator in the material master for CIF and for creation of Transportation lanes in APO. So if you create manually more transportation lanes in APO to other source locations it will all be considered as sources of supply unlike in R3.

    Hi Mono
    Are you planning to run MRP in R3 and also plan in APO for the same materials. Depending on the sequence one of the runs is wasted
    you normally plan selected materials in APO  and the rest in R3
    You can use the X0 in product master for APO relevant indicator and CIF only these materials to APO and plan it here
    as for the spl procurement keys
    If you have a special producrement key in R3 the Transportation lanes are created automatically with the  correct source of supply or you can ensure you manually create this(and block or delete the others) so the planning  will be the same as it would be in  R3

  • How to disable "special" f-key function on Apple Wireless Keyboard in Windows 7

    Hi.  I dual-boot my iMac using an Apple Wireless Keyboard.  In Mac OS's "Keyboard" system preference pane, I've chosen to treat the F-keys as actual F-keys, and not the "special" function keys, such as volume control and screen brightness.  This however does not carry over to the Windows environment.
    I cannot find an option to do this on the Windows 7 side.  I've tried SharpKeys (popular Windows freeware key-mapping registry editor), however the program doesn't recognize the key being pushed (unless I hold the "Fn" key, at which point, it sees it as the F# key).
    To reiterate, I'd like to know how to use the F1 through F12 keys as F1-F12 in Windows 7, without having to use the "Fn" key.

    Hi alexia416,
    If you would like to use your Apple keyboard in Boot Camp with the standard function keys as the default, you may find the following article helpful:
    Boot Camp: Use the function keys on an Apple keyboard
    For other keyboard-related Boot Camp issues, this article is also useful:
    Boot Camp: About keyboards and key assignment for Microsoft Windows - Apple Support
    Regards,
    - Brenden

  • VARRAY as Stored Proc output parameter

    VARRAY as Stored Proc output parameter
    I have an Oracle VARRAY data type declared as follows:
    CREATE TYPE NUMBER_ARRAY AS VARRAY(100) OF NUMBER;
    I have a stored procedure which takes a single input and
    returns a NUMBER_ARRAY as output:
    CREATE OR REPLACE PROCEDURE one_in_number_array_out(
    IN_PARAM IN NUMBER,
    OUT_NUMBER_ARRAY OUT NUMBER_ARRAY )
    IS
    BEGIN
    -- OUT_NUMBER_ARRAY getting populated here
    END one_in_number_array_out;
    I want to be able hit this proc using TopLink StoreProcedureCall objects and retrieve through a map.
    I thought I would be able to do something like:
    public void execute() {
         StoredProcedureCall call = new StoredProcedureCall();
              call.setProcedureName( getStoredProcedureName() );
              call.addNamedArgumentValue("IN_NUMBER_PARAM", new Double(324) );
              call.addNamedOutputArgument("OUT_NUMBER_ARRAY", "numberArray"); // use an alias
         ClientSession clientSession = .....getClientSession();
    // EXCEPTION OCCURS on following call:
              Map row = (Map) clientSession.executeSelectingCall( call ).firstElement();
              Object numberArray = row.get( "numberArray" );
              System.out.println("numberArray = " + numberArray);
    But, when I call the stored proc I get the following stack trace:
    LOCAL EXCEPTION STACK:
    EXCEPTION [TOPLINK-4002] (TopLink - 9.0.3 (Build 423)): oracle.toplink.exceptions.DatabaseException
    EXCEPTION DESCRIPTION: java.sql.SQLException: ORA-06550: line 1, column 7:
    PLS-00306: wrong number or types of arguments in call to 'ONE_IN_NUMBER_ARRAY_OUT'
    ORA-06550: line 1, column 7:
    PL/SQL: Statement ignored
    INTERNAL EXCEPTION: java.sql.SQLException: ORA-06550: line 1, column 7:
    PLS-00306: wrong number or types of arguments in call to 'ONE_IN_NUMBER_ARRAY_OUT'
    ORA-06550: line 1, column 7:
    PL/SQL: Statement ignored
    ERROR CODE: 6550
         at oracle.toplink.exceptions.DatabaseException.sqlException(Unknown Source)
         at oracle.toplink.internal.databaseaccess.DatabaseAccessor.executeDirectNoSelect(Unknown Source)
         at oracle.toplink.internal.databaseaccess.DatabaseAccessor.executeCall(Unknown Source)
         at oracle.toplink.threetier.ServerSession.executeCall(Unknown Source)
         at oracle.toplink.internal.queryframework.CallQueryMechanism.executeCall(Unknown Source)
         at oracle.toplink.internal.queryframework.CallQueryMechanism.executeCall(Unknown Source)
         at oracle.toplink.internal.queryframework.CallQueryMechanism.executeSelectCall(Unknown Source)
         at oracle.toplink.internal.queryframework.CallQueryMechanism.executeSelect(Unknown Source)
         at oracle.toplink.queryframework.DataReadQuery.executeNonCursor(Unknown Source)
         at oracle.toplink.queryframework.DataReadQuery.execute(Unknown Source)
         at oracle.toplink.queryframework.DatabaseQuery.execute(Unknown Source)
         at oracle.toplink.queryframework.ReadQuery.execute(Unknown Source)
         at oracle.toplink.publicinterface.Session.internalExecuteQuery(Unknown Source)
         at oracle.toplink.threetier.ServerSession.internalExecuteQuery(Unknown Source)
         at oracle.toplink.threetier.ClientSession.internalExecuteQuery(Unknown Source)
         at oracle.toplink.publicinterface.Session.executeQuery(Unknown Source)
         at oracle.toplink.publicinterface.Session.executeQuery(Unknown Source)
         at oracle.toplink.publicinterface.Session.executeSelectingCall(Unknown Source)
         at com.gs.lab.rr.db.plsql.gs_practice_pkg.OneInNumberArrayOutStoredProcedure.execute(OneInNumberArrayOutStoredProcedure.java:51)
         at com.gs.lab.rr.db.plsql.gs_practice_pkg.PracticeStoredProceduresTest.testOneInNumberArrayOutStoredProcedure(PracticeStoredProceduresTest.java:54)
         at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
         at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39)
         at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
         at java.lang.reflect.Method.invoke(Method.java:324)
         at junit.framework.TestCase.runTest(TestCase.java:154)
         at junit.framework.TestCase.runBare(TestCase.java:127)
         at junit.framework.TestResult$1.protect(TestResult.java:106)
         at junit.framework.TestResult.runProtected(TestResult.java:124)
         at junit.framework.TestResult.run(TestResult.java:109)
         at junit.framework.TestCase.run(TestCase.java:118)
         at junit.framework.TestSuite.runTest(TestSuite.java:208)
         at junit.framework.TestSuite.run(TestSuite.java:203)
         at org.eclipse.jdt.internal.junit.runner.RemoteTestRunner.runTests(RemoteTestRunner.java:329)
         at org.eclipse.jdt.internal.junit.runner.RemoteTestRunner.run(RemoteTestRunner.java:218)
         at org.eclipse.jdt.internal.junit.runner.RemoteTestRunner.main(RemoteTestRunner.java:151)
    INTERNAL EXCEPTION STACK:
    java.sql.SQLException: ORA-06550: line 1, column 7:
    PLS-00306: wrong number or types of arguments in call to 'ONE_IN_NUMBER_ARRAY_OUT'
    ORA-06550: line 1, column 7:
    PL/SQL: Statement ignored
         at oracle.jdbc.dbaccess.DBError.throwSqlException(DBError.java:134)
         at oracle.jdbc.ttc7.TTIoer.processError(TTIoer.java:289)
         at oracle.jdbc.ttc7.Oall7.receive(Oall7.java:573)
         at oracle.jdbc.ttc7.TTC7Protocol.doOall7(TTC7Protocol.java:1891)
         at oracle.jdbc.ttc7.TTC7Protocol.parseExecuteFetch(TTC7Protocol.java:1093)
         at oracle.jdbc.driver.OracleStatement.executeNonQuery(OracleStatement.java:2047)
         at oracle.jdbc.driver.OracleStatement.doExecuteOther(OracleStatement.java:1940)
         at oracle.jdbc.driver.OracleStatement.doExecuteWithTimeout(OracleStatement.java:2709)
         at oracle.jdbc.driver.OraclePreparedStatement.executeUpdate(OraclePreparedStatement.java:589)
         at oracle.toplink.internal.databaseaccess.DatabaseAccessor.executeDirectNoSelect(Unknown Source)
         at oracle.toplink.internal.databaseaccess.DatabaseAccessor.executeCall(Unknown Source)
         at oracle.toplink.threetier.ServerSession.executeCall(Unknown Source)
         at oracle.toplink.internal.queryframework.CallQueryMechanism.executeCall(Unknown Source)
         at oracle.toplink.internal.queryframework.CallQueryMechanism.executeCall(Unknown Source)
         at oracle.toplink.internal.queryframework.CallQueryMechanism.executeSelectCall(Unknown Source)
         at oracle.toplink.internal.queryframework.CallQueryMechanism.executeSelect(Unknown Source)
         at oracle.toplink.queryframework.DataReadQuery.executeNonCursor(Unknown Source)
         at oracle.toplink.queryframework.DataReadQuery.execute(Unknown Source)
         at oracle.toplink.queryframework.DatabaseQuery.execute(Unknown Source)
         at oracle.toplink.queryframework.ReadQuery.execute(Unknown Source)
         at oracle.toplink.publicinterface.Session.internalExecuteQuery(Unknown Source)
         at oracle.toplink.threetier.ServerSession.internalExecuteQuery(Unknown Source)
         at oracle.toplink.threetier.ClientSession.internalExecuteQuery(Unknown Source)
         at oracle.toplink.publicinterface.Session.executeQuery(Unknown Source)
         at oracle.toplink.publicinterface.Session.executeQuery(Unknown Source)
         at oracle.toplink.publicinterface.Session.executeSelectingCall(Unknown Source)
         at com.gs.lab.rr.db.plsql.gs_practice_pkg.OneInNumberArrayOutStoredProcedure.execute(OneInNumberArrayOutStoredProcedure.java:51)
         at com.gs.lab.rr.db.plsql.gs_practice_pkg.PracticeStoredProceduresTest.testOneInNumberArrayOutStoredProcedure(PracticeStoredProceduresTest.java:54)
         at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
         at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39)
         at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
         at java.lang.reflect.Method.invoke(Method.java:324)
         at junit.framework.TestCase.runTest(TestCase.java:154)
         at junit.framework.TestCase.runBare(TestCase.java:127)
         at junit.framework.TestResult$1.protect(TestResult.java:106)
         at junit.framework.TestResult.runProtected(TestResult.java:124)
         at junit.framework.TestResult.run(TestResult.java:109)
         at junit.framework.TestCase.run(TestCase.java:118)
         at junit.framework.TestSuite.runTest(TestSuite.java:208)
         at junit.framework.TestSuite.run(TestSuite.java:203)
         at org.eclipse.jdt.internal.junit.runner.RemoteTestRunner.runTests(RemoteTestRunner.java:329)
         at org.eclipse.jdt.internal.junit.runner.RemoteTestRunner.run(RemoteTestRunner.java:218)
         at org.eclipse.jdt.internal.junit.runner.RemoteTestRunner.main(RemoteTestRunner.java:151)
    Thanks in advance,
    John

    Using the SQL/ObjectRelational types as stored procedure arguments is not supported. But it may work...
    You should not pass in the reference to the array type. Instead, do something like this:
    call.addNamedOutputArgument("OUT_NUMBER_ARRAY", "OUT_NUMBER_ARRAY");
    Hope this helps. If not, I suspect it would take some technical services to do this as I don't think the source.zip contains the classes involved in this.
    - Don

  • Special procurement key 65 in MRP view.

    Hi gurus,
    I have two plants A & B.
    A = manufaturing plant.
    B = planning plant.
    In plant A, we have maintained special procurement key as 65(withdrawl from alt.plant B)
    In plant B, we have maintained special procurement key as 55 (production in another plant A)
    My question is that mandatory to maintain 65 in the plant A. What might be the effort if you not maintain.
    Please explain.
    thanks in advance.

    Alapati,
    You cant define special procurement key in both plants for the same material as defined by you. If Plant A is manufacturing you can have special procurement key assigned to the material in Plant B as "Production in Alternate Plant".
    Regards,
    Prasobh

  • Special procurement keys

    Hi experts,
    what are the special procurement keys for MRP related consignments and MRP related sub-contarcting
    rgds
    Lakshmi Reddy

    HI
    Special procurement key for subcontracting:-30
    Special procurement key for consignment:---10
    These can be found in MRP2 view of material master record
    Hope this will help you
    Reward if useful
    Thanks and Regards
    SHYAM.R

  • SPECIAL PROCUREMENT KEY CUSTOMISATION (OMD9)

    Any one can explain the various scenario where in we need to configure special procurement keys in customisation.
    1. When we need to create keys without "As BOM component" indicators?
    2. When we have to use the above indicators?
    Pl. explain with business scenario.

    One option is create new item category for stock transfer and assign that item category to the special procurement key in MRP and assign that tiem category in the purchasing document tyoe config so it will allow this only
    OR the simple solotuion without config is
    Create the screen variant using SHD0 transaction for the doc type ZIC and assing transaction code e.g
    ZINTRA and give the user so whenever they will enter this code, system will defulat the ZIC doc type for STO.

  • Satellite U840W/001 W8 Fn+Z not working in Special Function Key Mode

    Hi,
    I realised that the Fn+Z does not work when my Special Functions Key mode is on i.e: when I can control the volume by just pressing F9 without pressing the Fn button.
    However, when the Special Function Keys Mode is off (& I have to press Fn with the F# buttons to control the volume), only then does the Fn+Z switch the keyboard backlight on & off.
    When I open my function key program, the only option available is to either switch the notification settings on/off. There's no timer control or anything useful on it.
    My BIOS does not have any keyboard backlight setting, only the option to use the normal Fn+F# or to use the special function key mode.
    Please help me.
    Thanks

    >I realised that the Fn+Z does not work when my Special Functions Key mode is on i.e: when I can control the volume by just pressing F9 without pressing the Fn button.
    Hmm in my case using Windows 7, the Fn + Z works even if the Special Functions Key mode is enabled. But I cannot say for sure how it works running Win 8
    On Satellite U940 with Win 8, the Fn + Z works properly too (Special Functions Key mode ON)

  • Satellite L850 - Special function key not working properly

    Hi Everyone,
    I had Satellite L850 (pskg8a-07f001) running windows 8 64 bite for just 2 months.
    Just within this week, the special function key not working, each time I start the pc, i have to go into toshiba desktop assist then function key then click ok, it will working.
    But the touch pad has been set as enabled, also under keyboard setting has been set as special function mode. But don't know why each time start the pc have to go into function key box then click ok.
    When I bought it everything is ok, i can use the special function key to turn up and down the volume and disable wireless...etc
    Please advise. Thks a lot!

    Take a look here:
    Function key changes in Satellite and Qosmio 800 series
    http://aps2.toshiba-tro.de/kb0/TSB2903E00000R01.htm
    You can use the traditional FN + F key mode or just an F key mode.
    This can be enabled and disabled in BIOS or the HWSetup
    In BIOS go to Advanced -> System configuration -> Function key mode
    This mode can be changed
    Also be sure that Function Button option is enabled too

  • HP Pavilion Laptop; Only Special Function Keys are Working

    I got my first HP laptop, a HP Pavilion 17-e049wm Notebook, refurbished a few months ago when my original quit out. Until recently, I've been more than happy with its performance. However, a few weeks ago the keyboard started acting both weird and also not working. I'll try to provide as much information as I can, and thank you in advance for your assistance!
    Circumstances before the event:
    -The night before, my keyboard worked one hundred percent fine. I played some games and went to sleep with it closed and hibernating like I always have. The next morning, I took it up with me to play music as I showered. Before I'm accused of water-damaging it, my laptop was very far from shower, so no direct water contact occured, and also we shower with the door open, so there was no build up of steam or humidity that could've done it that couldn't be present in any other situation. I knew that it worked that morning, as I must have logged in to play my music. After closing it and bringing it to my car (without drops or any other jarring), I learned a few hours later that my keyboard had stopped working. 
    -My house doesn't have internet and I havn't recently installed anything, so it's doubtful that some kind of software did it to me.
    What the keyboard does(n't do): 
    -Almost every key doesn't work. The letters, esc, enter, shifts, fn, numberpad, caps lock, etc. I've tried them each, and none work.
    -There are two exclusions to the above statement:
         -The 'special' function keys; All of the keys that share space with my function keys work fine. So my mute, pause, change display, brightness controls, help shortcut, airplane mode, etc. work. So everything from F1 to F12 work.
              -Before anyone assumes that my fn key is stuck or something, the special part is the default. On my keyboard, you hold down the fn key to do the normal fn key functions (f11 skips to the next song, fn+f11 does fullsrceen).
              -Also, I'm not sure if my 'normal' functions work. I tried holding fn on this USB keyboard and then the f# keys, but the 'special' function still is the one that works. However, as I have no control, I don't know if that would have happened anyways.
         -The second exception, which makes me doubt that it is a hardware problem, is that if I hold 'X' and 'C' at the same time, the brightness lowers, as if I tapped my f2 key. Each of those do nothing on their own, but when pushed together, they act identical to the f2.
    -Another thing is that my ported keyboard's caps lock indicator light still shines when either the USB or on-screen's caps lock keys are used.
    What I've tried:
    -Turn it off and back on
    -Turn it off, take out battery, hold the power button, wait, turn on with/without battery
    -Uninstall keyboard driver, restart
    -Summoning a demon 
    -Tried to update driver (can't, up-to-date)
    -Check status through device manager (claims that it's running fine)
    I've basically tried everything I could find that seemed relatively useful from browsing the forums, but it's on my third week keyboardless, nothing works, and I'm so tired of using my girlfriends pretty, sparkling and bedazzled, purple USB keyboard from her days in middle school. If nothing works, I'll have to resort to the system resets and lose applications and my files, which would be a mad bummer yo.
    Thank you again for your help, internet. 

    @cbowman08 ,
    Hello and thank you so much for posting on the HP support forums. Now please I am not stating you have done anything wrong in any way.  This kind of thing happens all the time. 
    You do not need a bunch of steam to cause an issue with water for one thing.  
    Inside your notebook is a huge differential in temperature zones.  If you take a notebook into a shower room even if your water is slightly above room temp there is ample moisture in the air. 
    Air has to travel and if your notebook was on the counter and it is between your shower and the door, any moisture in the air gets to get heated way up and then gets to cool way down and gather on the little metal bits in your notebook.  
    It only takes one drop of water the size of a pin head to bridge a connection and cause a short.
    I hope this is not the case.  I am hoping that the connection cable for your keyboard has come loose.
    So to see if this is just a loose connection instead of a bit of moisture causing the issue here is a link to your maintenance guide,
    Maintenance and Service Guide
    This will show you have to get your system apart to check they keyboard connection.
    As well here is a link to how to gain access to the keyboard and its connection.
    HP Pavilion 17 Replace Keyboard HDD SSD Ram New Model Laptop.
    Check to make sure the keyboard cable didnt just come loose.  Very easy fix.  If it is connected and nothing is loose then you are looking at a replacement keyboard or if the board did get some moisture on it from condensation then you will need to have it sent in for repair.
    If that is the case you will want to contact phone support for repair options.
    Please call our technical support at 800-474-6836. If you live outside the US/Canada Region, please click the link below to get the support number for your region. http://www8.hp.com/us/en/contact-hp/ww-phone-assist.html
    I am hoping for the keyboard connection coming loose here.
    Have a great day and thank you again for posting let me know how it goes.
    Please click the "Thumbs Up" on the bottom right of this post to say thank you if you appreciate the support I provide!
    Also be sure to mark my post as “Accept as Solution" if you feel my post solved your issue, it will help others who face the same challenge find the same solution.
    D5GR
    I work on behalf of HP

  • Special Functions keys not working on Satellite C50 - Windows 8.1

    Hello,
    Please could someone help me out.
    I have a Toshiba Satellite C50-A0393 that I got a few months ago with Windows 8.1 already installed (64 bit). Today I got a message saying I needed to look at the PC Health, a Toshiba blue message concerning the access agreement, and I noticed that there were three upgrades that needed to be done, the only one I can remember being the Toshiba Video Player. I think that another one had to do with the charger light?
    I don't know.
    But once I restarted my laptop after the updates I noticed that the special function keys were not working (i.e. the volume, mute, pause and play, etc.). i then went onto the Toshiba Desktop Assist and into system settings and selected the keyboard tab. I then made sure the setting for special function mode was selected.
    Now, when that setting is in place, certain keys work but for F3, F5, F6, etc and when I want to use the special functions only the volume up and down work when pressing 'Fn', but special function mode is still selected? Only those two work, not the mute or flightmode or bluetooth, which was working normally before the upgrades.
    I have googled but cannot find anything specific to 8.1, or not relating to upgrading to 8.1. I cannot find the flashcard utility and do not want to try something where I do not know what I am doing. How can I get these special function keys working again normally? Sorry for the long message but I wanted to give as much info as possible.
    Many thanks,
    Melanie

    Hi
    It sounds strange to me that a Toshiba update (Toshiba Video Player, etc) would affect the function key functionality.
    Nevertheless the function key (F1-F10) can be used in combination with or without the FN button. This depends on the special function key mode.
    In case you want to use the F1-F12 functions without the pressing FN button, the function key mode should be enabled (should be set to special function mode)
    Here the full details how it works:
    https://aps2.toshiba-tro.de/kb0/HTD2503B90001R01.htm
    Now it these buttons would not work even if the FN button has been pressed, then there is some problem with the software.
    First of all I would recommend you to set the BIOS to default because this function key mode can be changed in BIOS too.
    After that, check if the key would work. If not, reinstall the
    Toshiba Function Key Utility
    And Toshiba System Driver
    You can also check if the essential service has not been disabled.
    Start the Task Manager and go to start up items. There you should enable all Toshiba apps and services and then restart.

  • Reg: Subcontracting(30) in special requirement key

    Hi,
    Could you pls explain ab special procurement key for 30 subcontracting for the materail.
    when we run the MRP using subcontracting material, what things needs to created.
    Thanks,
    P.Arunkumar.

    Hello Arun,
    Subcontracting means, you want to perform any operation but you don't have resource for that in that case the vendor is provided with materials (components), which he uses to produce the finished product.
    I think in MRP no need do any thing, please refer the link http://help.sap.com/saphelp_46c/helpdata/en/f4/7d321a44af11d182b40000e829fbfe/frameset.htm
    Hope clear to you.
    Regards
    R. Brahmankar

Maybe you are looking for

  • I am unable to email in elements 11.

    I am unable to email via Elements 11. I am shooting in both raw and jpeg. Also, when I prepare the email the final photo (that is never sent) looks blurry. Help!

  • HOW TO WRITE ,SAVE A FILE IN BLOB COLUMN

    Hi, I have to write a simple utl file and store it in a column of blob data tye..i hav written a piece of code..it shows invalid path as error..please kindly help me create or replace procedure simp_file as fhandler                    utl_file.file_t

  • Can't find how and where to downaload the Oracle Client 8i and Developer 6i

    All, I am looking for downloads at OTN for the following. 1. Oracle Client 8i 2. Oracle Forms and Reports 6i I had them installed on my m/c but lately I have been getting SQL*Net connection failures. I have been suggested to install the whole develop

  • Username and password default for BAM database

    Hi everyone, I have installed in my machine a virtual machine wich have the Oracle BAM 10 installed. We are trying to connect to the BAM database but the problem is I dont know the user default to do it. I also have in my machine(real machine) the BA

  • Conversion from char to byte

    can anybody to convert char which is unicode in java as one byte. i want to print that byte as ascii. i tried below method. char temp='s'; ByteBuffer buff= ByteBuffer.wrap(some byte array of some size); buff.putChar(temp); out.writeByte(buff.getChar(