Status 56 in receiving system

Hi SDNers,
By BD87 transaction, I have to catch the status in receiving system.
To perform this task, I do the following steps:
1) Go to BD87 trx.
2) Select an idoc with status 3.
3) Execute the Tracing IDOCS system-wide (Trace IDOC).
I should obtain an idoc with status 53 in receiving system.
However, I finally obtain an idoc with status 56.
Where could I check to find the problem?
Thanks in advance for your help
Regards
Leo

Hi a®s,
Thanks for your soon asnwer. I've checked in the receiving system by WE20 and there is not an entry for my system source.
Are you talking about that when you say "idoc type is maintained"?
Thanks again
Regards
Leo

Similar Messages

  • Error status 51 in receiver system

    Hi ,
        I am trying to synchronise Purchase Requisitions of two different Application Servers of SAP  through IDOC. I am using the IDOC type "PREQCHANGE01". I am doing the mapping of IDOC segments on the sender system programmatically. I have mapped all the fields required for the purchase Requisition.
    Idoc is successfully transferred from sender system to receiver system, In my receiver system, while trying to view the inbound idoc in "WE02", it is in status 51 and giving errors as follows.
    1. Enter Document Type
    2. Document contains no items
    3. Instance <My PR No> of object type PurchaseRequisition could not be changed.
    Please help me solve this.
    Thanks in Advance,
    Cheers,
    Vivek.

    Hello,
    The Idoc is made up of 3 Main segments,
    Control Record
        IDoc number, Direction, Status, Basic type, Extension, Message type ,Sender or Recipient information, Port, Partner number,  
         Partner Type, SAP Release
    Data Records
        The structure of a data segment depends on the segment type
    Status Records
        Status: the status reported by the segment
        Message: the text describing the status.
    You need to fill the map the Idoc Data Record with the PR details.
    Check the below link [IDOC1|http://wiki.sdn.sap.com/wiki/display/ABAP/CustomIdocTransferingfromOneapplicationserverintoAnotherapplicationserver]
    [IDOC2|http://wiki.sdn.sap.com/wiki/display/ABAP/ALEandIDocs]
    These links will help you understand the mapping and how you need to code your logic.
    Regards,
    Abhishek

  • How to get the status idoc from recieveing system

    Hi All,
    In our requirement we will be sending an idoc to the recieveing system. we are planning to get the staus of the idoc.
    How can you  recieve the status of the idoc that idoc has been is saftly reached to target server.
    Can any one share the solution if you have confirgured  the same before.
    We are planning to use : Middleware.

    Hi Anil,
    If get the status 03 means your idoc successfully send to receiving system port. But in the receiving system if there any issue in processing you can't get these updated status automatically from receiving system. You know Idoc works in asynchronous mode. To get the status you need send one idoc with status (error , success ot warning) from receiving system to sending system.
    Thanks
    Subhankar.

  • IDoc Status 02 ( Could not find code page for receiving system )

    Hi All,
    I am getting Idoc status 02 when I am trying to send IDocs from ECC to PI system ( Production ).
    Error description.
    Could not find code page for receiving system
    Message no. E0266
    Diagnosis
    For the logical destination PIP001, you want to determine the code page in which the data is sent with RFC. However, this is not currently possible, and the IDoc cannot yet be dispatched.
    Procedure for System Administration
    Possible causes are:
    1. The entry no longer exists in the table of logical destinations.
    2. The target system could not be accessed at runtime.
    3. The logon language is not installed in the target system.
    4. In the destination system, no logon language is maintained
    Please help.
    Thanks - Vinay.

    Hi Vinay,
    Status 02 occurs when data is not passed to port suceessfully. Check the RFC desination  is working fine and your able to connect to target system and also check correct port is assigned.
    Regards,
    Vinod.

  • Idoc in status 03 - not received by receiving system

    Hello All,
    I have researched a lot on this topic on the forum - but what I am facing is something peculiar - so posting the complete scenario.
    I have three interfaces based on change pointers mechanism where change pointers have been activated for message type HRMD_A.
    There are three distribution models which filter the same message type and send to receiving system GIS – for the logical systems:
    FI
    Concur
    Russia
    When IDoc is triggered using standard program RHALESMD (transaction RE_RHALESMD - HR: Evaluate ALE Change Pointers), there could be three or less IDocs produced depending on the filter criteria.
    For example, you could have an IDoc each for all above three partners.
    When the above program is triggered in the development system all three IDocs reach GIS.
    All the custom code and configuration is transported from DEv to QA. When I trigger the above program in QA, not all  IDoc reaches GIS. Others stay in the system in status 03.
    If I check tRFC queue (transaction BD75), there are no IDocs in the queue.
    If I use another program to change status from 03 to 12, the status changes, but IDoc still does not reach receiving system.
    I have compared Dev and QA systems, deleted and generated partner profile, distribution model, port in QA – but nothing works.
    Not all IDocs reach GIS.
    I read on the forum that I need a commit work. But because I am using a standard program - RHALESMD - where do I commit work?
    Your inputs will be helpful.

    Hi Suneel,
    Please go to transaction SM58 and check if the IDocs are stucked up on the t-rfc queue. If so, you can right click and choose Execute LUW to release them.
    or
    Execute the program RSARFCRD and get the corresponding Transaction id and then execute the program RSARFCSE for processing the entries in TRFC Queue.
    Regards,
    Ferry Lianto

  • Infopackage Idocs in status 2 - could not find code page for receiver system

    Hi,
    We just migrated our production system from BW 7.01 non unicode to BW 7.4 on HANA.
    We now encounter issues with idocs while loading data into bw from our ECC5 source. When we analyze idocs in the source system it appears with the message "could not find code page for receiver system"
    One weird thing is that the idoc seems to have been created before we started the infopackage in bw.. We controlled system time and AS time and everything seems ok.
    We did not encounter this issues on our previous migration test runs..
    Hope someone can help
    Christophe

    Hi,
    Thanks for responding. We finally found out what the problem was.
    We have two applications servers on our ECC with 2 different OS. One of them could not reach the new BW HANA server.
    Regards
    Christophe

  • Error "codepage could not be determined for the receiver-system"

    Hi,
    we use the idoc-adapter to send message from mySAP ERP to PI.
    All worked fine.
    So, this morning I have changed the datatype of the messageId from "char" to "int" in mySAP ERP in the customizing menue (install param). So, no message received in SAP PI.
    When I start transction "we05" in mySAPERP" I get the following error:
    "codepage could not be determined for the receiver-system" status 02.
    I have changed the datatyp to "char" but the same probleme
    Can anybody help me please?
    Regards
    Stefan

    This error shouldn't occur unless there is some modification at the OS level codepages.
    Please check the entried in the RFC destination for connecting to the XI system. Unicode settings.
    Regards,
    Prateek

  • Issue:Creation of Extended iDOC data entries in receiving system.

    Hi all,
    I have extended standard IDOC MATMAS05 for classification view.I am receiving the data successfully on recewing side.And i  have done coading in user exit to store data in database  table inside
    IDOC_INPUT_MATMAS01- function module.
    When i execute the BD10 from sending sytem and view the idoc at receiving end from WE05 i can see the idoc but when i try to see the material i cant see the classification(extended) view in mm03.Rest of the views are created .When i execute the idoc from WE19 ,Classification(extended) view gets created.
    Please guide me so that the CLASSIFICATION view get automatically created in receiving system without using WE19.
    Thanks.

    Yes i used this function module-
    CALL FUNCTION 'BAPI_OBJCL_CREATE'
                  EXPORTING
                    objectkeynew            = objectkeynew1
                    objecttablenew          = 'MARA'
                    classnumnew             = wa_classnumnew1
                    classtypenew            = z1sklart-klart              "classtypenew1
                    status                  = '1'
      STANDARDCLASS           =
      CHANGENUMBER            =
                    keydate                 = sy-datum
      NO_DEFAULT_VALUES       = ' '
    IMPORTING
      CLASSIF_STATUS          =
                  TABLES
      ALLOCVALUESNUM          =
                    allocvalueschar         = allocvalueschar2[]
      ALLOCVALUESCURR         =
                    return                  = return1
    *WAIT UP TO 1 SECONDS.
                CALL FUNCTION 'BAPI_TRANSACTION_COMMIT'
                 EXPORTING
                   wait          = 'X'
    IMPORTING
      RETURN        =
    Please explain me how to maintain the Views Status at MARA general info segment level.

  • PI 7.11 handling EOIO Backlog in Engine Status for a Receiver Component

    Hi
    In our PI 7.11 we have for more days had an EOIO Backlog of 120 messages for one of our receiver components when checking the Engine status Backlog tab (RWB -> Component Monitoring -> Adapter Engine -> Engine Status -> Backlog tab -> Receiver Components section)
    My question is how I can process the backlog. There is nothing to see in either smq1/smq2/sm58 on the PI system or in smq1/smq2 on the receiver system.
    Thanks in advance.
    Mikael

    HI,
    Go to MessagingSystem of the server and there the option for the EOIO Sequence Monitoring will be available and can make use of that...
    MessagingSystem link is http://host:port/MessagingSystem there the message which bloking the other messages can be seen...
    HTH
    Rajesh

  • Outbound IDOC not received at the receiver system.

    Hi,
    Im sending an IDOC from sap to a non-sap system. During this process, from sap system it is executing successfully without any erros and the status is also '03' .
    The problem is that the other system is unable to receive the IDOC sent from SAP system.
    The connection is like TCP/IP and the registered server program is given as 'PROGRID' in RFC destination.
    I would like to know what would be the possible cases where this IDOC is not received at the receiver system.
    The configuration is perfect as per my knowledge. Just want to confirm one thing 'do i need to include any message type such as "SYNCH".
    Awaiting for your solutions.
    Thanks
    rohith

    Hi,
    If the IDOC is sent successfully from the sender system then the status of the IDOC will be '03' , no matter whether the receiver has received the IDOC or not.
    As per your case,
    Check the Partner Profile parameters , whether the basic and extended message types are used properly.
    The message type Synchron (Sync) is generally needed in Inbound IDOC side. Check whether you have added SYNCH or not.
    Hope this Helps.
    Regards,
    Abhinab Mishra.
    Experience is the name everyone gives to their mistakes.

  • Idoc not found in the receiving system

    Hi Experts,
    In the sending system idoc status is 03 (Data passed to port OK), but in the receiving system the idoc is not there. How to rectify this error?
    Thanks & Regards,
    Soumya.

    Hi Soumya,
               Check the RFC connections, becoz in the sending system once the IDOC is sent the status becomes 03 it does not check whether the IDOC has sent to the received system, if there are any errors before sending the IDOC it will not send and the status will be 01, so check the RFC connections at sending and receiving systems.......
    Reward points if this helps............
    Regards,
    Ravi G

  • ALE using HRMDA message type - Comit not perform in receiving system

    Hi,
    I want to use ALE to transfer HR master data between two ECC instances. I have set-up all the configuration; distribution profile, filter etc... I tried to transfer the master data using standard SAP report RHALEINI.
    The iDoc is generated and transfer correctly in the receiving system. The final status of the iDoc is 53 - Application document posted. The issue we have is that the comit to tables is not happening. Infotypes remains empty even if the status of the iDoc says it was posted. We are trying to transfer infotype 0000, 0002, 0001 and 0006
    Anyone can help ?....
    Thanks
    Louis

    Hi Ted,
    Thanks for your answer,
    Autorization is the first thing that we consider. We generate the IDOC by the program RBDMIDOC .
    The job's user is the sap_all authorization. So it should not related with auth.
    And this does not always occur. For example, two days ago it occurs, but today does not occur.
    Best Regards
    Hasan.

  • Idoc failed in Bi system "Could not find code page for receiving system".

    Dear Experts,
    i am getting below error ,Idoc failed in Bi system "Could not find code page for receiving system".
    All the idocs have been successfully posted except one which is giving this error
    Idoc status 02 - could not find code page for receiver system.
    Please guide me
    thanks
    vamsi

    Hello Vamsi,
    check Note 647495 - RFC for Unicode ./. non-Unicode Connections
    If your ERP system sends e. g. chinese data to the SCM system, how should the system know which codepage to use? You have to set the MDMP flag in your ERP system in SM59 and configure in the MDMP extended settings which codepage should be used for what language.
    Please check this thread - IDoc error - Could not find code page for receiving system
    Hope it helps,
    Thanks & Regards,
    Amit Barnawal

  • Vlans dhcp status are not received

    Hello,
    I am configuring vlan on sg300-20 in dhcp mode.
    One  vlan that is directed connected to the adsl router get ip address and when I connect host to the ports in this vlan they also receive ip address and can go on internet.
    The other four vlans dhcp status are not received.
    Kindly help me check this. Thanks
    Below is the config log:
    switch4ba497#sh running-config
    config-file-header
    switch4ba497
    v1.2.9.44 / R750_NIK_1_2_584_002
    CLI v1.0
    file SSD indicator encrypted
    ssd-control-start
    ssd config
    ssd file passphrase control unrestricted
    no ssd file integrity control
    ssd-control-end cb0a3fdb1f3a1af4e4430033719968c0
    vlan database
    vlan 5,10,20,30,40
    exit
    voice vlan oui-table add 0001e3 Siemens_AG_phone________
    voice vlan oui-table add 00036b Cisco_phone_____________
    voice vlan oui-table add 00096e Avaya___________________
    voice vlan oui-table add 000fe2 H3C_Aolynk______________
    voice vlan oui-table add 0060b9 Philips_and_NEC_AG_phone
    voice vlan oui-table add 00d01e Pingtel_phone___________
    voice vlan oui-table add 00e075 Polycom/Veritel_phone___
    voice vlan oui-table add 00e0bb 3Com_phone______________
    ip dhcp relay address 192.168.3.1
    ip dhcp information option
    no boot host auto-config
    bonjour interface range vlan 1
    hostname switch4ba497
    line telnet
    exec-timeout 0
    exit
    no passwords complexity enable
    username cisco password encrypted 7af78c911d5b48bea1dc2449d9d89513abeb4be5 privilege
    15
    ip http timeout-policy 0 http-only
    ip name-server  192.168.1.1 192.168.3.1
    ip telnet server
    interface vlan 1
    ip address 192.168.2.254 255.255.255.0
    no ip address dhcp
    interface vlan 5
    name WAN
    ip address dhcp
    interface vlan 10
    name Studio
    ip address dhcp
    interface vlan 20
    name Service
    ip address dhcp
    interface vlan 30
    name Admin
    ip address dhcp
    interface vlan 40
    name Data
    ip address dhcp
    interface gigabitethernet1
    switchport mode access
    interface gigabitethernet2
    switchport mode access
    switchport access vlan 10
    interface gigabitethernet3
    switchport mode access
    switchport access vlan 10
    interface gigabitethernet4
    switchport mode access
    switchport access vlan 10
    interface gigabitethernet5
    switchport mode access
    switchport access vlan 10
    interface gigabitethernet6
    switchport mode access
    switchport access vlan 10
    interface gigabitethernet7
    switchport mode access
    switchport access vlan 10
    interface gigabitethernet8
    switchport mode access
    interface gigabitethernet9
    switchport mode access
    switchport access vlan 20
    interface gigabitethernet10
    switchport mode access
    switchport access vlan 20
    interface gigabitethernet11
    switchport mode access
    switchport access vlan 20
    interface gigabitethernet12
    switchport mode access
    switchport access vlan 20
    interface gigabitethernet13
    switchport mode access
    switchport access vlan 30
    interface gigabitethernet14
    switchport mode access
    switchport access vlan 30
    interface gigabitethernet15
    switchport mode access
    switchport access vlan 30
    interface gigabitethernet16
    switchport mode access
    switchport access vlan 30
    interface gigabitethernet17
    switchport mode access
    interface gigabitethernet18
    switchport trunk native vlan 40
    interface gigabitethernet19
    switchport mode access
    switchport access vlan 5
    interface gigabitethernet20
    switchport trunk native vlan 5
    switch4ba497#sh ip int
        IP Address         I/F       Type     Directed   Precedence   Status
                                              Broadcast
    0.0.0.0/32          vlan 10   DHCP        disable    No         Not
                                                                    received
    0.0.0.0/32          vlan 20   DHCP        disable    No         Not
                                                                    received
    0.0.0.0/32          vlan 30   DHCP        disable    No         Not
                                                                    received
    0.0.0.0/32          vlan 40   DHCP        disable    No         Not
                                                                    received
    192.168.2.254/24    vlan 1    Static      disable    No         Valid
    192.168.3.102/24    vlan 5    DHCP        disable    No         Valid
    switch4ba497#
    Also i do not understand why the ip address is 0.0.0.0/32 because the dhcp server ip address is 192.168.3.1

    Dear Customer,
    Thank you for reaching Small Business Support Community.
    In Layer 2 system mode, only the management VLAN can be configured with a static or dynamic IP address. In Layer 3 system mode, all the interface types (ports,LAGs, and/or VLANs) on the device can be configured with a static or dynamic IP. Configuring the device to work in either mode is performed in the Administration >System Settings page
    When a DCHP Client starts a discovery process, it assigns a dummy IP address 0.0.0.0 before the real address is obtained. This dummy address has the status of “Not Received”.
    Pretty much your problem should be solved by changing to Layer3 system mode.  Please let me know if anything comes up and/or if there is any further assistance I may help you with.
    Kind regards,
    Jeffrey Rodriguez S. .:|:.:|:.
    Cisco Customer Support Engineer
    *Please rate the Post so other will know when an answer has been found.

  • Could not find coding page for receiving system

    Hi,
    We have set up the configuration of RFC connections in SM59. We want to send an IDoc from a Unicode to a non-Unicode system. Message 'Could not find coding page for receiving system' appears. We activated some solutions described in OSS notes and added the required authorization to the communication user but it still doesn't work. What else can cause (solve) this problem?
    Regards, Jan

    Hello Jan,
    I had the following situation:
    After seup of an ALE/IDOC scenario with another SAP but Non unicode system sometimes the outbound PROJECT idocs failed with the error message "Could not find code page for receiving system". Status of Idoc was 02. When reprocessed some minutes later with report RBDAGAIN it worked.
    It turned out that for what'o'ever reason the connectivity was down for a very short time but long enough to get the Idocs failed.
    That's what I meant with the error text could be misleading.
    We solved this problem with a daily job with report RBDAGAIN for reprocessing.
    Regards
    Michael

Maybe you are looking for