Using SXMB_MONI to view input and output messages

Within XI can I view both the input message and the output message ?
I have an IDOC Order being transformed into XML format.  Using SXMB_MONI I can see the transaction and the input IDOC Order but cannot see the resulting output XML Order.  Is it possible to do or is there some other transaction?

Hi,
Check in SXMB_MONI for xml message it is appearing the pipeline steps , if not do the below setting to appearing piepline steps in moni.
Tcode : SXMB_ADM
Execute integration engine and configuration
click on specific configuration
go to change mode
Category : RUNTIME
Parameter :  LOGGING
Current value : 1
then save..test the scenario once again.
now go to moni double click the message check the xml message has left hand side pipeline steps are appearing..
  Expand Inbound mesage -> Expand the Payloads -> Double maindocument you will find the input payload
  Expadn Technical routing -> Expand the Payloads -> Double maindocument you will find the output payload
  then you will find the output xml payload.
Regards,
Venu.

Similar Messages

  • SSIS: How to use one Variable as Input and Output Parameter in an Execute SQL Task

    Hello,
    i need your help,I'm working on this issue since yesterday and have no idea how to deal with it.
    As I already said in the tilte i want to start a stored procedure via a Execute SQL Task which has around 15 prameters. 10 of these should be used as input AND output value.
    As an example:
    i have three  Variable:
    var1    int        2
    var2    int     100
    var3    int     200
    the stroed procedure:
       sp_test
          @var1 int
          @var2 int output
          @var3 int output
       AS
       BEGIN
            SET @var2 = @var2 * @var1
            SET @var3 = @var3 + @var1
       END
    So in the Execute SQL Task i call the Stored Procedure as follwos:
        Exec sp_test  @var1 = ?, @var2 = ? output, @var3 = ? output
    (I use an OLE DB Connection)
    The parameter mapping is as follows:
    User::Var1        input                   numeric              0                 -1
    User::Var2        input/output         numeric              1                 -1
    User::Var3        input/output         numeric              2                 -1
    Now my problem. If i set  Var2 and Var3 as Input parameter the values are still the same after running the package. If i set them to a output value the are both Null because the procedure doesnt get any values.
    I already tried to list them a second time - like
        User::Var2        input                  numeric              1                 -1
        User::Var2        output                 numeric              1                 -1
    or i use a new variable
        User::Var2                  input                  numeric              1                 -1
        User::Var2Return        output                 numeric              1                 -1
    but i alwas get the error
    "Multiple-step OLE DB operation generated errors. Check each OLE DB status value, if available. No work was done."
    Has anybody an idea how I can solve this problem?
    Thanks a lot.
    Kind Regards,
    Alice

    Hi Alain,
    thx for your answer.
    I have around 15 procedures called one after the other to calculated and modify my values. Each procedure is responsible for an other but overlapping set of variables. So i thought it would be a good idea to call them one after the other with the needed variables via a execute sql task.
    So if i use a result set, how i get my stored procedure to return 10 values? I would have to use a Function instead of a procedure, wouldn't i?
    As if i have 15 procedures this would be a lot of work.
    But thanks a lot for the idea. I think an other idea would be to create one function which calls all stored procedures and returns all the calculated values as a result set, wouldn't it?.
    Kind Regards.
    Alice

  • How can I use a different driver for audio input and output?

    I did a search of course, and came up with something about an aggregate. I have no idea what this is, how to do it, or if it would even work for me.
    What I am trying to do is:
    1) Record into Logic Express using my Tascam US-122.
    2) Have playback come out of my computer sound system, not the Tascam.
    If I go over to the Audio setup window, I can only record when the driver is set to Tascam US-122. Likewise, I can only listen to sound when my Built-In Audio is selected. It gets rather annoying going between the two.
    So, would this aggregate thing solve my problem? If so, how do I do it? Thanks for any help!
    -allen

    Yes it should do what you want.
    Go to "Audio Midi Setup", and go to the Audio menu and click "Open Aggregate Device Editor". The interface is pretty simple but if you do get stuck, just use the help function in Audio Midi Setup, as it has a step by step guide.
    Then when you return to logic, go to the Preferences>Audio>Drivers section and select Aggregate Device as the new driver rather than either the built in sound or the tascam. Then the inputs and outputs will apply to BOTH devices.

  • How to use a bluetooth cellphone for audio input and output

    Hello, I was wondering how to set-up my Mac Book so that I can use my bluetooth cellphone for audio in and audio out. Ideally, I would like to use my handset for talking on iChat and Skype. Has anyone had any luck doing this? When I bond my cellphone these optiosn do not appear. I know that this is easy to do on a Windows machine but I am not sure about how to do it on my Mac Book.
    Thanks!

    Yes it should do what you want.
    Go to "Audio Midi Setup", and go to the Audio menu and click "Open Aggregate Device Editor". The interface is pretty simple but if you do get stuck, just use the help function in Audio Midi Setup, as it has a step by step guide.
    Then when you return to logic, go to the Preferences>Audio>Drivers section and select Aggregate Device as the new driver rather than either the built in sound or the tascam. Then the inputs and outputs will apply to BOTH devices.

  • I have on;y one audio port can i use it for input and output at the same time?

    i have the new macbook pro 13 in and i want to connect aguitar as input and output on an amp but i have only one audio port

    You can't use the jack as an input and output simultaneously. The solution is to look for a USB or Firewire interface to get your guitar sound into the computer.

  • Table name input. and output i need  all rows and columns  using procedures

    hi,
    question: table name input. and output i need all rows and columns by using procedures.
    thanks,
    To All

    An example of using DBMS_SQL package to execute dynamic SQL (in this case to generate CSV data in a file)...
    As sys user:
    CREATE OR REPLACE DIRECTORY TEST_DIR AS '\tmp\myfiles'
    GRANT READ, WRITE ON DIRECTORY TEST_DIR TO myuser
    /As myuser:
    CREATE OR REPLACE PROCEDURE run_query(p_sql IN VARCHAR2
                                         ,p_dir IN VARCHAR2
                                         ,p_header_file IN VARCHAR2
                                         ,p_data_file IN VARCHAR2 := NULL) IS
      v_finaltxt  VARCHAR2(4000);
      v_v_val     VARCHAR2(4000);
      v_n_val     NUMBER;
      v_d_val     DATE;
      v_ret       NUMBER;
      c           NUMBER;
      d           NUMBER;
      col_cnt     INTEGER;
      f           BOOLEAN;
      rec_tab     DBMS_SQL.DESC_TAB;
      col_num     NUMBER;
      v_fh        UTL_FILE.FILE_TYPE;
      v_samefile  BOOLEAN := (NVL(p_data_file,p_header_file) = p_header_file);
    BEGIN
      c := DBMS_SQL.OPEN_CURSOR;
      DBMS_SQL.PARSE(c, p_sql, DBMS_SQL.NATIVE);
      d := DBMS_SQL.EXECUTE(c);
      DBMS_SQL.DESCRIBE_COLUMNS(c, col_cnt, rec_tab);
      FOR j in 1..col_cnt
      LOOP
        CASE rec_tab(j).col_type
          WHEN 1 THEN DBMS_SQL.DEFINE_COLUMN(c,j,v_v_val,2000);
          WHEN 2 THEN DBMS_SQL.DEFINE_COLUMN(c,j,v_n_val);
          WHEN 12 THEN DBMS_SQL.DEFINE_COLUMN(c,j,v_d_val);
        ELSE
          DBMS_SQL.DEFINE_COLUMN(c,j,v_v_val,2000);
        END CASE;
      END LOOP;
      -- This part outputs the HEADER
      v_fh := UTL_FILE.FOPEN(upper(p_dir),p_header_file,'w',32767);
      FOR j in 1..col_cnt
      LOOP
        v_finaltxt := ltrim(v_finaltxt||','||lower(rec_tab(j).col_name),',');
      END LOOP;
      --  DBMS_OUTPUT.PUT_LINE(v_finaltxt);
      UTL_FILE.PUT_LINE(v_fh, v_finaltxt);
      IF NOT v_samefile THEN
        UTL_FILE.FCLOSE(v_fh);
      END IF;
      -- This part outputs the DATA
      IF NOT v_samefile THEN
        v_fh := UTL_FILE.FOPEN(upper(p_dir),p_data_file,'w',32767);
      END IF;
      LOOP
        v_ret := DBMS_SQL.FETCH_ROWS(c);
        EXIT WHEN v_ret = 0;
        v_finaltxt := NULL;
        FOR j in 1..col_cnt
        LOOP
          CASE rec_tab(j).col_type
            WHEN 1 THEN DBMS_SQL.COLUMN_VALUE(c,j,v_v_val);
                        v_finaltxt := ltrim(v_finaltxt||',"'||v_v_val||'"',',');
            WHEN 2 THEN DBMS_SQL.COLUMN_VALUE(c,j,v_n_val);
                        v_finaltxt := ltrim(v_finaltxt||','||v_n_val,',');
            WHEN 12 THEN DBMS_SQL.COLUMN_VALUE(c,j,v_d_val);
                        v_finaltxt := ltrim(v_finaltxt||','||to_char(v_d_val,'DD/MM/YYYY HH24:MI:SS'),',');
          ELSE
            v_finaltxt := ltrim(v_finaltxt||',"'||v_v_val||'"',',');
          END CASE;
        END LOOP;
      --  DBMS_OUTPUT.PUT_LINE(v_finaltxt);
        UTL_FILE.PUT_LINE(v_fh, v_finaltxt);
      END LOOP;
      UTL_FILE.FCLOSE(v_fh);
      DBMS_SQL.CLOSE_CURSOR(c);
    END;This allows for the header row and the data to be written to seperate files if required.
    e.g.
    SQL> exec run_query('select * from emp','TEST_DIR','output.txt');
    PL/SQL procedure successfully completed.Output.txt file contains:
    empno,ename,job,mgr,hiredate,sal,comm,deptno
    7369,"SMITH","CLERK",7902,17/12/1980 00:00:00,800,,20
    7499,"ALLEN","SALESMAN",7698,20/02/1981 00:00:00,1600,300,30
    7521,"WARD","SALESMAN",7698,22/02/1981 00:00:00,1250,500,30
    7566,"JONES","MANAGER",7839,02/04/1981 00:00:00,2975,,20
    7654,"MARTIN","SALESMAN",7698,28/09/1981 00:00:00,1250,1400,30
    7698,"BLAKE","MANAGER",7839,01/05/1981 00:00:00,2850,,30
    7782,"CLARK","MANAGER",7839,09/06/1981 00:00:00,2450,,10
    7788,"SCOTT","ANALYST",7566,19/04/1987 00:00:00,3000,,20
    7839,"KING","PRESIDENT",,17/11/1981 00:00:00,5000,,10
    7844,"TURNER","SALESMAN",7698,08/09/1981 00:00:00,1500,0,30
    7876,"ADAMS","CLERK",7788,23/05/1987 00:00:00,1100,,20
    7900,"JAMES","CLERK",7698,03/12/1981 00:00:00,950,,30
    7902,"FORD","ANALYST",7566,03/12/1981 00:00:00,3000,,20
    7934,"MILLER","CLERK",7782,23/01/1982 00:00:00,1300,,10The procedure allows for the header and data to go to seperate files if required. Just specifying the "header" filename will put the header and data in the one file.
    Adapt to output different datatypes and styles are required.

  • Multiple inputs and outputs using DAQmx VIs

    Hello,
    I am fairly new with the LabView programming language.  I have a few training books that I have been reading, and I have been following online tutorials and reading the forums.  However, I have come to a problem where I don’t see a clear solution.  I am using LabView 2009 (9.0f3) and DAQmx VIs.
    I am using a NI 9172 chassis PLC, with two 9201 AI cards, 9217 AI RTD card, 9472 DO card, 9263 AO card, and two 9237 AI Bridge cards.
    I am reading eight analog inputs with the 9201 cards, two analog RTD inputs with the 9217 card, three digital outputs with the 9472 card, three analog outputs with the 9263, and eight analog inputs with the 9237 cards.
    I wrote a simple program to test one digital output task, two of the analog output tasks, and a single analog input task.  I put all of them in the same while loop, and it worked perfectly.  However, when I add analog input tasks to the same loop, I get an error 200022.    So I tested each sensor individually by changing the channel before each run.  I searched error 200022 and found that this is because I cannot start another analog input task until the previous one ends.  With this said, I don’t know how to acquire an analog voltage in the same task as an analog RTD voltage.  Both inputs take different constants in the start task DAQmx icon.
    Attached is my test program.  It is titled “Test All”. This is the program I used to test the various sensors.  I tested the input sensors one at a time, and it worked fine.  A few tasks are written just to test functionality, and will be added to later.  The data is only displayed on the screen.  I will add triggers and data write to disk functions later.  This program works now, but if I add more analog inputs, it will generate the 200022 error.
    Can someone show me how to correctly write the code for multiple inputs and outputs using DAQmx?  All training materials and tutorials I can find all show a single input or single output, not multiples of each.  Thanks for looking.
    -Randy
    Attachments:
    TestAll-NI.vi ‏32 KB

    Hi RandyC,
    The Knowledge Base article Using Different Types of DAQmx Global Channels in the Same Task goes into a little more depth of what Bryan is talking about, and it also includes some example code to help show what to do.
    Hope that helps,

  • How to get input and output using math interface toolkit

    Hi,
    I am fairly new to labview and i am trying to convert my labview code
    into matlab mex files using math interface toolkit. I cant see any
    input or output terminals when i try to convert the code to mex files
    even though my vi has plenty of inputs and outputs that should be
    available during conversion.
    just to cross  check i made another vi in which i inputted an
    array of data to an fft and outputted it to an array again. i tried to
    convert this code to mex files but was still not able to see any input
    or output terminals, which makes me believe that i must be doing
    something wrong at the very basic level and inspite of trying really
    hard for some days now i have not been able to figure out that might be.
    So please help.
    I am attaching the basic vi that i created along with the link that i followed for converting labview code to mex files.
    http://zone.ni.com/devzone/conceptd.nsf/webmain/EEFA8F98491D04C586256E490002F100
    I am using labview 7.1
    Thanks
    Attachments:
    test.vi ‏17 KB

    Yes, you've made a very basic mistake. You have front panel controls and indicators but none of them are connected to the VI's connector pane. right click on the VI's icon and select "Show Connector". You use the wiring tool to select a connection there and then select a control or indicator. Use the on-line help and look up the topic "connector panes". There are some sub-topics on how to assign, confirm, delete, etc.

  • How to control (the input and output) EXE file after I call it using exec?

    Hi,
    I knew that I can use runtime.exec() to call one EXE file, and this works. But this EXE has two characteristics:
    1. After this exe starts, it asks user to input number such as 1 or 2 onto computer screen, then press return. Then the exe will start the calculation.
    2. after it starts calculation, it prints 3 columns of numbers onto the screen.
    My two questions are:
    1. How to use java to input the number such as 1 or 2 automatically? this EXE can not work like this in DOS command line:
    C:> file.exe parameter
    The parameter is the number such as 1 or 2 that I wanna input.
    2. how to redirect the 3 columns of numbers from computer screen to txt file?
    My colleague can solve these two questions using Mathematica. So I know that definitely there is at least one solution for it. I just can not do it using Java. This wierd exe file bothered me a lot and I really wish that I can get help from someone in java community.
    Thank you!
    Tony

    When you call Runtime.exec, you get a Process object. (I presume something similar happens when you use ProcessBuilder.) Process has methods with names getOutput, getInput, and getError. These correspond to the standard input, standard output, and standard error streams of the spawned process.
    You can read and write to the process on the streams corresponding to input and output that the process writes to the console.
    [add]
    In fact, you should be grabbing and reading the output/error streams anyway, because of the points raised by the Traps article. Google "Java Runtime exec traps" and you'll probably get a link to this JavaWorld article, which describes common Runtime.exec problems and how to solve them.
    Edited by: paulcw on Jun 15, 2010 4:09 PM

  • How to view the input and output layouts created in the planning folder?

    Hi all,
    How to view the input and output layouts created in the planning folder in the bw 3.5?
    Thanks
    Pooja

    Hi,
    You can refer to this link. How to create planning folder and executing the planning folder.
    http://help.sap.com/saphelp_nw04/Helpdata/EN/5d/7c4b52691011d4b2f00050dadfb23f/frameset.htm
    Hope this helps

  • Synchronisation of input and output using myDAQ

    Hello!
    I am currently using the NI myDAQ and use both analoge output. and both analoge inputs. The sampling rate needs to be as high as 200k Hz. (Also within the while loop I do quite a lot of data manipulation and saving into text files.)  My vi works generally fine, but I still have to problems:
    1. How can I ensure that the read and write tasks are synchronised? I found out that it is not possible to use other trigger than the sample clock for write and read tasks using the myDAQ. (Is this right?) So as a workaround for me it is not important that the tasks start at the same time, but I want to ensure that the delay between "Start Write Task" and "Start Read Task" always is the same.  Is this possible? And how can I realise it?
    2. If I want to generate a non periodical signal that is not constant, how do I best generate this? At the moment I use a Sine Waveform.vi with a frequency of 0 and I change the offset input with every loop. I also tried to use the FormulaWaveform.vi but with this my produced waveform seemed to stop after completing the "number of samples in the waveform". But the sampling info must be the same for both AO channels I use, so I cannot simply increase this number.
    Thanks a lot for any help! Jules
    Attachments:
    MyDAQReadWrite.vi ‏72 KB

    hi Jules,
    If you only want to ensure that the delay between "Start Write Task" and "Start Read Task" always is the same, you can realize it with a simple while loop (with Wait Until Next ms Multiple).
    But if you want to synchronize for example both analog input, you can see how it works in different examples. Following Path is shows you how to find these examples:
         In LabVIEW -> Help -> Find Examples... Brows(Brows according to Task): Hardware Input and Output -> DAQmx -> Synchronization -> "Analog Input Synchronizantion.vi"
    To generate a non periodical signal that is not constant, you can change the offset input every loop. If you want to manipulate the offset while running you can also use local variables in the loop.
    In this case you could manipulate for example with a slide control.
    Regards,
    grroesis

  • Data types used in a sub VI - selecting the correct input and output types?

    data types used in a sub VI - selecting the correct input and output types?
    I can never work out how to choose an input or output format for Subvi's.
    I want to create a SubVI for the code in red. I needs an VI Server Reference compatible input and an output that goes to  a waveform.
    Thanks in advance.
    Attachments:
    data types.PNG ‏11 KB

    GerdW,
    I realise now I have taken us in the wrong direction. apologies for that.
    History, this is not my code and I do not own the process and NOT my preferred method of using it. I was looking for a simple way to make subtle changes.
    What we do - We use these programs to collect data from typically 6 pressures and 6 temperature probes and capture RS232 / USB VISA strings from sensors.
    So every few weeks / months or up to a year we rearrange each sensor location to suit the new process. I did not write the code. I cannot change the procedure too much without resistance.
    So headers in the CSV file have the DaqMX string passed through the code. Great.
    Other data to the CSV file comes from calculations or extracted from the VISA string. Hence why we have headers with "Untitled 1 ()". These values also go to a History Chart.
    So I was looking for a simple way to read the the local variable label as it is always linked to the front page indicator. People can cope with editing the indicator label, save the VI and hit run.
    TL;DR - GerdW is now a psychologist.
    Attachments:
    data to csv and history chart.png ‏1043 KB

  • Can you perform simultaneous timed digital input and output using a PCI-6120?

    Is it possible to do simultaneous timed digital input and output using a PCI-6120? It seems that timed digital operations require using the group read/write commands, which utilize an entire port. Since the PCI-6120 has only 1 digital I/O port, I would like to be able to use 2 lines as outputs and 1 line as input, and do both in a deterministic fashion. i.e. create a digital signal with known pulse widths and read an input line at a known time after the outputs were set. Is this possible to do with only one digital I/O port?

    Hello,
    This can be done in LabVIEW. There is actually an example that installs with NI-DAQ.
    Below is a link to a Knowledge Base that explains how to find the correlated digital I/O examples.
    http://digital.ni.com/public.nsf/websearch/B849664604EB34B886256D12005B5520?OpenDocument
    Just take a look at the example titled �Continuous CDIO with external clock (E).vi�
    Best regards,
    Justin Tipton
    National Instruments

  • Synchronize input and output tasks to start at the same sample point [C++ NI_DAQmx Base]

    I'm trying to initiate the analog input and output streams to start reliably at the same sample. I've tried triggering the output from the start of the input using the following code [NI-DAQmx Base 2.1 under Mac OS X with an M-Series multifunction board]. It compiles and runs, but gives an error message at the call to "DAQmxBaseCfgDigEdgeStartTrig". Any suggestions about synchronized I/O on this platform?
    #include "NIDAQmxBase.h"
    #include
    #include
    #include
    #define DAQmxErrorCheck( functionCall ) { if ( DAQmxFailed( error=( functionCall ) ) ) { goto Error; } }
    int main( int argc, char *argv[] )
    // Task parameters
    int32 error = 0;
    TaskHandle inputTaskHandle = 0;
    TaskHandle outputTaskHandle = 0;
    char errorString[ 2048 ] = {'\0'};
    int32 i;
    time_t startTime;
    // input channel parameters
    char inputChannelList[] = "Dev1/ai0, Dev1/ai1";
    float64 inputVoltageRangeMinimum = -10.0;
    float64 inputVoltageRangeMaximum = 10.0;
    // output channel parameters
    char outputChannelList[] = "Dev1/ao0, Dev1/ao1";
    char outputTrigger[] = "Dev1/ai/StartTrigger";
    float64 outputVoltageRangeMinimum = -10.0;
    float64 outputVoltageRangeMaximum = 10.0;
    // Timing parameters
    char clockSource[] = "OnboardClock";
    uInt64 samplesPerChannel = 100000;
    float64 sampleRate = 10000.0;
    // Input data parameters
    static const uInt32 inputBufferSize = 100;
    int16 inputData[ inputBufferSize * 2 ];
    int32 pointsToRead = inputBufferSize;
    int32 pointsRead;
    float64 timeout = 10.0;
    int32 totalRead = 0;
    // Output data parameters
    static const uInt32 outputBufferSize = 1000;
    float64 outputData[ outputBufferSize * 2 ];
    int32 pointsToWrite = outputBufferSize;
    int32 pointsWritten;
    for( int i = 0; i < outputBufferSize; i++ )
    outputData[ 2 * i ] = 9.95 * sin( 2.0 * 3.14159 * i / outputBufferSize );
    outputData[ 2 * i + 1 ] = -9.95 * sin( 2.0 * 3.14159 * i / outputBufferSize );
    // ------------------- configure input task -----------------------
    DAQmxErrorCheck ( DAQmxBaseCreateTask( "", &inputTaskHandle ) );
    printf( "Created input task\n" );
    DAQmxErrorCheck ( DAQmxBaseCreateAIVoltageChan( inputTaskHandle, inputChannelList, "", DAQmx_Val_RSE, inputVoltageRangeMinimum, inputVoltageRangeMaximum, DAQmx_Val_Volts, NULL ) );
    printf( "Created AI Voltage Chan\n" );
    DAQmxErrorCheck ( DAQmxBaseCfgSampClkTiming( inputTaskHandle, clockSource, sampleRate, DAQmx_Val_Rising, DAQmx_Val_ContSamps, samplesPerChannel ) );
    printf( "Set sample rate\n" );
    // ------------------- configure output task -----------------------
    DAQmxErrorCheck ( DAQmxBaseCreateTask( "", &outputTaskHandle ) );
    printf( "Created output task\n" );
    DAQmxErrorCheck ( DAQmxBaseCreateAOVoltageChan( outputTaskHandle, outputChannelList, "", outputVoltageRangeMinimum, outputVoltageRangeMaximum, DAQmx_Val_Volts, NULL ) );
    printf( "Created AO Voltage Chan OK\n" );
    DAQmxErrorCheck ( DAQmxBaseCfgSampClkTiming( outputTaskHandle, clockSource, sampleRate, DAQmx_Val_Rising, DAQmx_Val_ContSamps, samplesPerChannel ) );
    printf( "Set sample rate\n" );
    // trigger output when input starts
    DAQmxErrorCheck ( DAQmxBaseCfgDigEdgeStartTrig( outputTaskHandle, outputTrigger, DAQmx_Val_Rising ) );
    printf( "Set output trigger\n" );
    // ------------------- configuration -----------------------
    // write output signal
    DAQmxErrorCheck ( DAQmxBaseWriteAnalogF64( outputTaskHandle, pointsToWrite, 0, timeout, DAQmx_Val_GroupByScanNumber, outputData, &pointsWritten, NULL ) );
    printf( "Write output signal\n" );
    // set up input buffer
    DAQmxErrorCheck ( DAQmxBaseCfgInputBuffer( inputTaskHandle, 200000 ) ); // use a 100,000 sample DMA buffer
    // initiate acquisition - must start output task first
    DAQmxErrorCheck ( DAQmxBaseStartTask( outputTaskHandle ) );
    DAQmxErrorCheck ( DAQmxBaseStartTask( inputTaskHandle ) );
    // The loop will quit after 10 seconds
    Dr John Clements
    Lead Programmer
    AxoGraph Scientific

    Hi Michael,
    First of all, thanks very much for taking the time to investigate this problem! Much appreciated.
    You asked for "an actual error code you got and any description that is given". The full output from the program that I posted earlier in this thread is appended to the end of this message. In summary, following the call to...
    DAQmxErrorCheck ( DAQmxBaseCfgDigEdgeStartTrig( outputTaskHandle, outputTrigger, DAQmx_Val_Rising ) );
    ... with ...
    char outputTrigger[] = "Dev1/ai/StartTrigger";
    ...the error message is ...
    DAQmxBase Error: Specified route cannot be satisfied, because the hardware does not support it.
    You asked "specifically which M series device you are using"? It is the PCIe 6251 (with BNC 2111 connector block). I'm testing and developing on an Intel Mac Pro (dual boot OS X and Windows XP).
    You asked for "the location you pulled the code from". Here it is...
    http://zone.ni.com/devzone/cda/epd/p/id/879
    ...specifically from the file "Multi-Function-Synch AI-AO_Fn.c".
    I adapted the NI-DAQmx calls to their NI-DAQmx Base equivalents.
    Finally, you asked "Is the trigger necessary, or do you just need to know that the measurements are running on the same clock?". I believe that some kind of sychronized trigger is necessary in my situation (correct me if I'm wrong). Timing is crucial. Say I initiate an analog output stream that delivers a voltage command step 5 ms from the onset. I need to record the response (analog input stream) so that its onset is accurately aligned (synchronized) at 5 ms. A typical recording situation would stimulate and record a short data 'sweep', then wait for the (biological) system to recover, then stimulate and record another short sweep, and repeat. I need all the recorded sweeps to align accurately so that they can be averaged and analyzed conveniently.
    I definitely do not want my customers to rely on an expensive external TTL pulse generator to initiate and synchronize each 'sweep'. That would effectively eliminate the cost advantage of an NI board, as well as adding unnecessary complexity in setup and use. It would be a show-stopper for me.
    It seems perverse, but would it be possible to use a digital output channel connected directly to a digital input chanel to trigger the input and output streams?
    Regards,
    John.
    Full output from test program. Compiled with gcc 4 under OS X...
    [Session started at 2007-05-23 14:17:01 +1000.]
    LoadRuntime: MainBundle
    CFBundle 0x303cc0 (executable, loaded)
    _CompatibleWithLabVIEWVersion: linkedAgainst: 08208002
    _CompatibleWithLabVIEWVersion: result= false, mgErr= 1, theActualVersion= 00000000
    _CompatibleWithLabVIEWVersion: linkedAgainst: deadbeef
    _CompatibleWithLabVIEWVersion: Reseting Linked Against
    _CompatibleWithLabVIEWVersion: linkedAgainst: 08208002
    _CompatibleWithLabVIEWVersion: result= true, mgErr= 0, theActualVersion= 00000000
    _CompatibleWithLabVIEWVersion: linkedAgainst: 08208002
    _CompatibleWithLabVIEWVersion: result= true, mgErr= 0, theActualVersion= 00000000
    com.ni.LabVIEW.dll.nidaqmxbaselv
    CFBundle 0x313760 (framework, loaded)
    {type = 15, string = file://localhost/Library/Frameworks/nidaqmxbaselv.framework/, base = (null)}
    Amethyst:Library:Frameworks:nidaqmxbaselv.framework
    2007-05-23 14:17:02.248 test-ni[4445] CFLog (21): Error loading /Library/Frameworks/LabVIEW 8.2 Runtime.framework/resource/nitaglv.framework/nitaglv: error code 4, error number 0 (no suitable image found. Did find:
    /Library/Frameworks/LabVIEW 8.2 Runtime.framework/resource/nitaglv.framework/nitaglv: mach-o, but wrong architecture)
    CFBundle 0x1751fdc0 (framework, not loaded)
    Created input task
    Created AI Voltage Chan
    Set sample rate
    Created output task
    Created AO Voltage Chan OK
    Set sample rate
    DAQmxBase Error: Specified route cannot be satisfied, because the hardware does not support it.
    test-ni has exited with status 0.
    Dr John Clements
    Lead Programmer
    AxoGraph Scientific

  • TTYA Input and Output

    Hi All,
    I am new to this forum as well as new to SUN.
    I tried to boot a Sun Blade 100. The message that appears on the screen is Keyboard not found. use ttya Input and Output.
    I have only a normal MS Keyboard which cannot be connected to SUN. Do we need to have a special Keyboard. Whether we have to use USB Keyboard...
    I just want to know more about TTYA input and output.
    Thanx.

    Hi Martin
    Thanx for your info.I Connected using a second computer that has a serial port as well as a null-modem connection cable.
    The following appears in the second computer..I am not able to type anything from the second computer keyboard..Is there any reason for it..?
    Sun Blade 100 (UltraSPARC-IIe), No Keyboard
    Copyright 1998-2003 Sun Microsystems, Inc. All rights reserved.
    OpenBoot 4.10.6, 512 MB memory installed, Serial #51719739.
    Ethernet address 0:3:ba:15:2e:3b, Host ID: 83152e3b.
    Boot device: disk File and args:
    Bad magic number in disk label
    Can't open disk label package
    Evaluating:
    Can't open boot device
    Type boot , go (continue), or login (command mode)
    >

Maybe you are looking for

  • Agent Desktop Issue

    I've been having some users get logged out of CAD for no reason.  Here is the jtapi log of when this happens.  Any ideas on what might be causing this??? 929: Dec 03 14:42:36.306 CST %JTAPI-PROTOCOL-7-UNK:(P7-10.130.0.12) received Response: com.cisco

  • Can't move big files also with Mac OS Extended Journaled!

    Hi all =) This time I can't really understand. I'm trying to move a big file (an app 9 GB large) from my macbook app folder to an external USB drive HFS+ formatted, but at about 5.5 GB the process stop and I get this error: "The Finder can't complete

  • Sourcing of GOA in Extended Classic Scenario

    Hello all, We are using the <u>extended classic scenario</u> with both Purchase Contracts and Global Outline agreements. Is it possible to use the GOA in the back-end as a source of supply in the sourcing transaction in SRM? What setting do I have to

  • Problems under Windows USB Drivers (Apple Wired Keyboard)

    Hello guys, somehow I have some issues after installing Windows 7 regarding the USB Drivers: if I install the "Intel(R) 7 Series/C216 Chipset Family USB 3.0 eXtensible Host Controller Installation Disk - 1E31"-drivers, doesn't matter if I do it from

  • Help help help me pleas my i pod will not turn on

    HELP HELP HELP HELP me  please my i pod will not turn on...