Field Point marked as invalid in project

I have posted a question regarding Field Point issues. If you have Field Point experience could you please check the post.
I'm posting here to reach a broader audience.
Thanks.
Mark Yedinak
"Does anyone know where the love of God goes when the waves turn the minutes to hours?"
Wreck of the Edmund Fitzgerald - Gordon Lightfoot

Hello Mark,
Based on the behavior you've described, I would check the local .iak configuration file, which may have become corrupted during the crash.  With newer versions of the driver (which you'd be using in 2012) you rarely need to interact with the iak file directly but there's still a local copy cached and this is what's loaded when you add a FieldPoint to a project. You may also want to double-check that the FP controller, module, and channel names don't have any odd characters that would interfere with resolving a network path (eg @  /  \  % etc.).
Regards,
Tom L.

Similar Messages

  • Problem setting project end point (can't access the end point marker)

    I can't seem to set my project end point because the slider control that adjusts the spacing of the measures is obstructing my pointer from being able to click on the end point marker. Any hints as to how I can move the coation of this slider control so that I can access the end point marker with my pointer?

    6ftmama wrote:
    FYI - the end point marker now turns into a bracket when you hover over it.
    THe End-of-Project Marker doesn't change at all. What you see is a change of the Mouse Pointer.
    This is called a "Click Zone" where the Mouse Pointer changes to different shapes when moving over or click on an object or an area in the window.
    Here the Mouse Pointer changes to "Trim Tool" or "Resize Tool".
    Pointer Tool:
    Resize Tool:
    It is the same Tool wne you move the Mouse Pointer of the right edge of a Region to resize its length.
    Hope that helps
    Edgar Rothermich
    http://DingDingMusic.com/Manuals/
    'I may receive some form of compensation, financial or otherwise, from my recommendation or link.'

  • How can I get all the options of Field Point Explorer 3.0.2 in Measuremen​t and Automation Explorer 3.1?

    I am a student using LabVIEW and Compact Field Point to implement a
    senior design project in Electrical and Computer Engineering.  We
    have LabVIEW 7.1 and a cFP-2020 and additional modules.  We are
    trying to use the CTR-500 module to output a pulse train to drive a
    stepper motor.  We have found instructions online of how to do
    this, but they all use Field Point Explorer.  The instructions
    make use of options in Field Point Explorer that are not included in
    Measurement and Automation Explorer (the software included with the
    cFP).
    I have downloaded Field Point Explorer 3.0.2 and followed the
    directions.  Now, in LabVIEW, when I using the newly created .iak
    file, I get a dialogue asking to find the SubVI: 'FP Read (Float Array
    -IO).vi'.  Included with LabVIEW are subvis for FP Read, but not
    with the float array part.  So I figure I cannot use Field Point
    Explorer created .iaks with LabVIEW 7.1.  So how cannot I access
    the same options in Measurement and Automation that I was able to find
    in Field Point Explorer?
    Thanks

    Hi,
    FieldPoint Explorer is no longer used to configure FieldPoint systems. However, I do not think that the configuring your system in FieldPoint Explorer is causing the error.
    FieldPoint systems are now setup in Measurement and Automation Explorer (MAX).  Information on setting up FieldPoint systems in MAX can be found in the MAX help under: Installed Products>> FieldPoint. Also, I recommend upgrading to the latest FieldPoint driver and version of MAX.  The FieldPoint VI's will be slightly different when you upgrade, so there is a good chance that this will eliminate the error.
    Regards,
    Hal L.

  • Bogus error message: "The field jnlp has an invalid value: https."

    We are running into a variant of an old bug. With a Windows XP client using JRE 1.5.0_05, we get:
    {noformat}Launch File Error: The field <jnlp> has an invalid value: https
    Java 1.4+ is required for HTTPS support{noformat}
    which of course is a strange thing for a 1.5 JRE to be squawking about. We found a Sun bug report 6433293 that reports this behavior as occuring on Solaris but not on Windows. We're seeing it on Windows. The bug report suggests that the error message text is the "wrong message" and may be totally unrelated to the actual problem (although it is triggered by having an https URL in the "href" attribute of the <jnlp> tag).
    Because of our customer environment, upgrading the JRE beyond 1.5.0_05 is NOT an option for us. I googled the message and found one blogpost that suggested the error may be related to the XML encoding (which seems surprising, but they claimed changing the encoding fixed the problem for them). I tried fiddling with the encoding values, but to no avail. Anyone know anything about this bug, and any possible workarounds?

    We finally found the solution to this, so I will follow up for the sake of posterity. Thanks, Andrew, for the pointer to JaNeLa. While it didn't tip us off to this particular problem, it did get us thinking in the right direction: that there was something about the JNLP file, completely unrelated to what the error message was reporting, that was causing the problem. Turns out that the Java 1.5.0_05 WebStart JNLP parser had a bug, such that it was tripped up by a JNLP file containing more than one XML comment in immediate succession. It seems unbelievable, but it was completely reproducible. Our JNLP file began like this:
    <?xml version="1.0" encoding="utf-8"?>
    <!-- here's a valid XML comment -->
    <!-- here's another valid XML comment, but it freaks out JWS 1.5.0_05 -->
    <jnlp spec="1.0+" codebase="https://ourserver/ourApp" href="https://ourserver/ourApp/ourApp.jnlp"/> By accounts, this was patched in 1.5.0_10, and we know that the problem didn't occur in 1.6.0_13. In case anyone else has this problem, that's something to look for. (Note: this isn't the only cause of this erroneous error message. It apparently got printed out when the parser was unhappy about various things. I saw another report that someone had a problem with their "encoding" attribute value on their xml header, and fixing that solved their problem.)

  • Help on field point subvi

    Hi to all, sorry for not making things clear.
    I'm designing a project about field point temperature control. This is my first time doing on field point so please help me as much as possible. thank you..I found an example of field point temperature control and some of the subvi are missing, i.e. FP open, read, write, and so on. also, this project is a turn on/off fan with a relay. however, i'm using three fans and it should turn on/off at different time depending on the set of temperature,,, for example, fan1 will turn on at 25 degree C and turn off at 30 degree C,,then Fan 2 will turn on at 35 and off at 40,,, and fan 3 will do the same at 45 and off at 50 degree C,,
    Can one Thermo couple do the job or should i have all Three thermo couple.
    thank you in advance

    Hello nw,
    I will try to address all of your questions in an organized manner.
    1.  To change the [c]FP-TC-120 readings from millivolts to degrees you
    will need to use Measurement and Automation Explorer (MAX). 
                A.  Find your
    FieldPoint controller under Remote Systems in MAX. 
                B.  Right-click
    on your controller and choose to Find Devices. 
                C.  Then, a
    dialog box will appear so you can name your FieldPoint controller. 
                D.  You can use
    the default name or re-name the controller yourself.  Click ok when you
    have named your controller.
                E.  This will display
    all of the devices you have connected to your controller.
                F.  Click on the
    [c]FP-TC-120 module and select the Channel Configuration Tab.
                G.  A Range option
    will appear so you can change the measured range of the module to
    degrees.  You can also define the thermocouple type on the Channel
    Configuration            
              Tab.
    2.  If you want to turn on and off your heater and fan based on the
    temperature, the example you found has the basic structure.  It will read
    the temperature in via the FieldPoint Read.  You can replace the pid.vi
    with a case structure to write different values to your relay module via the
    FieldPoint Write VI.
    3.  I am assuming that you are using a [c]FP-TC-120.  If this is
    correct, you will be unable to measure the temperature via a thermistor. 
    The [c]FP-TC-120 is a thermocouple input module and only able to measure
    voltages and temperatures via thermocouples.
    If you need further assistance, please provide a comprehensive list of the
    hardware you are using. 
    Also, I would recommend looking through the FieldPoint Help
    which can be found at C:\Program Files\National
    Instruments\FieldPoint\documentation\Online Help\fplv.chm.  If you are new
    to LabVIEW, taking a look at this KnowledgeBase
    Article that contains many LabVIEW learning resources.
    Message Edited by Ching P. on 09-05-2007 10:39 PM
    Regards,
    Ching P.
    DAQ and Academic Hardware R&D
    National Instruments
    Attachments:
    Temp_Range_new.jpg ‏96 KB

  • Field Point FP-1000 communication issue - Device found but offline in MAX

    Hello,
    I am trying to control several field point PLCs in a level tank. They are communicating through a FP-1000 module. I am able to add the devices through a configuration file in MAX. But there is an error saying " The device is offline. Make sure the device is connected and its power is on. " All of the field point PLCs have green light on for both " Power" and "Ready". I am not sure what the issue is here. I am using Labview 2014 and Field Point , VISA drivers are installed. Please see attached pictures for details.
    Many Thanks
    FLiu
    Attachments:
    IMG_1359.JPG ‏4812 KB
    IMG_1360.jpg ‏2220 KB
    IMG_1361.jpg ‏2251 KB

    Thanks for your reply. I installed the most updated version for both ones. It turns out the configuration file for FP-1000 bank points to the wrong COM port for the Serial communication. I am able to communicate with the system now. I do have another problem through. I only have excutable labview files and a configuration file for the control system that I am working with. The original VI project file were lost. After importing the right configuration file in MAX, I installed the excutables and tried to run it. There is no response at all.The labview only last a few seconds and stopped. Any thoughts are greatly appreciated.
    Thanks
    Fliu

  • How to configure field point cFP2120

    Hi,
         I am doing a project using LabVIEW... I am using field point cFP2120  as the interface... The problem is that my PC is not detecting the field point... Can you suggest a solution???

    Hi jaks,
       From the user manual:
    Number of Flashes        Error Condition
    0 (stays lit)                     The cFP-21xx did not power on correctly. Contact
                                           National Instruments for assistance.
    1                                     The cFP-21xx is in reset mode or is unconfigured. Make
                                           sure the RESET IP switch is in the OFF position and
                                           restart the controller. Refer to the Measurement &
                                           Automation Explorer Help for FieldPoint for more
                                           information about configuration.
    2                                     The cFP-21xx has detected an error in software. This
                                           usually occurs when an attempt to upgrade the software
                                           is interrupted. Repeat the software upgrade process.
    3                                     The cFP-21xx is in safe mode. Either the controller is
                                           ready for software installation or the SAFE MODE
                                           switch is in the ON position.
    4 (or more)                    The cFP-21xx has detected an unrecoverable error.
                                          Contact National Instruments for assistance.
    In which of these condition are you?  If you never configured that module, and led flashes once, you have the  correct start-up condition, but it is strange that you cannot access module; check if Windows Fierewall is turned ON or if Antivirus' firewall is ON, they can be blocking MAX in connecting to device!
    graziano

  • Unable to Build VC++ application it showing error 1 LINK : fatal error LNK1104: cannot open file 'NiFieldPoint71D.lib' but I am Using Measurement Studio 2009 ,NI DAQ 7.01 and Field Point 6.05.

    I am having a application in Visual Studio 2003 on Windows XP  , Now I am Migrating the application in Visual Studio 2005 on Windows-7 .
    In my Development PC , I was install Measurement Studio 2009 ,  NI DAQ 7.01 and Field Point 6.05.
    my application is Showing following error:
    Linking...
    LINK : fatal error LNK1104: cannot open file 'NiFieldPoint71D.lib'
    Build log was saved at "file://c:\EdacsNt\Source\SaftyServices\NICfpDAQDl?l\Debug\BuildLog.htm"
    NICfpDAQDll - 1 error(s), 0 warning(s)
    When I copy from NiFieldPoint71D.lib library from Measurement Studio 7.1 and put in :\Program Files\National Instruments\MeasurementStudioVS2005\VCNET\Lib.
    my application is Showing following error:
    1>Linking...
    1>atlsd.lib(atltrace.obj) : error LNK2005: "unsigned int (__stdcall* ATL::g_pfnGetThreadACP)(void)" (?g_pfnGetThreadACP@ATL@@3P6GIXZA) already defined in NiFieldPoint71D.lib(StdAfx.obj)
    1>atlsd.lib(atlbase.obj) : error LNK2005: "class ATL::CAtlWinModule ATL::_AtlWinModule" (?_AtlWinModule@ATL@@3VCAtlWinModule@1@A) already defined in NiFieldPoint71D.lib(StdAfx.obj)
    1>   Creating library ..\..\lib\debug\NICfpDAQDll.lib and object ..\..\lib\debug\NICfpDAQDll.exp
    1>..\..\bin\debug\NICfpDAQDll.dll : fatal error LNK1169: one or more multiply defined symbols found
    I want to ignore NiFieldPoint71D.lib from using project setting(Linker->Input->ignore Specific Library ) but still it is showing same error.
    In the project Setting I am done following setting:
    "C:\Program Files\National Instruments\MeasurementStudioVS2005\VCNET\Lib";"
    C:\Program Files\National Instruments\NI-DAQ\Lib"
    Linker->Input->ignore Specific Library: mfcs71d.lib;libc.lib;'NiFieldPoint71D.lib
    Please provide some solution.
    Thanks
    Nityanand

    You posted this in the LabVIEW forum.
    Are you programming in LabVIEW?
    There is a separate Measurement Studio for VC++ forum. http://forums.ni.com/t5/Measurement-Studio-for-VC/bd-p/231

  • [solved] Various MP3s are marked as [invalid encoding] with Quod Libet

    Various MP3s are marked as [invalid encoding] when I attempt to open them in Quod Libet. These same MP3s open fine in VLC. I checked and I have everything related to gstreamer installed: good, bad, ugly, ffmpeg. My thinking is that should do it but it doesn't. The error listed is "Resource not found." But of course Quod Libet does have the correct path to the file. Also, in case this could be related, the files all appear to show raw unicode in the comments tag rather than the comments. LIke so: 000010A3 000010E3 000057E6 000062C2 0004F705 0005B198 00008000 00008000 00005A9C 00005A3F.  Rather than... well I'm not sure what that's supposed to be.
    I checked the wiki on gstreamer but and glanced at Pulse's but Pulse, ALSA, and OSS don't seem to be relevant.
    Last edited by xidar (2012-06-28 21:36:29)

    Yep I went back and looked and it's everything, except one song, that has an "é" and also the bôa album. I'll file a bug report about and call it solved.
    Also, I cleared all the extra tags and the junk text (which was probably a custom tag at  one point) that was in comments and it works. So maybe iTunes screwed up the formatting and Ex Falso took and mangled all of my comments because of it and something to do with unicode.
    Last edited by xidar (2012-06-28 22:01:26)

  • Problemi di startup con field point 1000

    Gentile Signore,
    Nella nostra azienda Electrolux Home Products stiamo usando i vostri moduli Field Point tipo FP 110, FP 120 e FP 1000.Il SW che stiamo usando è fornito dalla CANARY LABS e la versione del Field Point è la 3.0. Vi allego la risposta del tecnico della CANARY LABS che ha visionato gli errori e mi ha consigliato di contattarvi.
    Saluti
    Attachments:
    errors.txt ‏2 KB

    I only know of the standard stuff on FieldPoint from NI.  The Quickstart Guide is good for wiring, and there is HELP>FieldPOINT in LabVIEW itself (you need to make sure the FieldPOINT software option is installed on your computer as it isn't in the default installation of LabVIEW).
    After connecting you FP-1000 to an RS-232 COM Port, the next step is to open a new LabVIEW Project and Add New "Targets and Devices...":
    From there you can get to the configuration screen:
    -- James
     BTW, after the initial learning hurdle, FieldPOINT is very easy to use.

  • Using field points how the dc voltage measuremen​t is done?

    i am new to labVIEW..  Using cFP-AI 100  i am trying to measure a dc voltage [5volts].. all the field point items are configured on MAX. when the example VI provided runs there is error indicating that the connection is broken or network module is not pwered on.. but i have checked both .. What may be the problem?

    Hi ELUE,
    When you say "all the FP items are configured on MAX," does that mean you can see and connect to the device? Can you take readings in MAX from the FieldPoint module I/O menu under the Data Neighborhood?
    If you're able to read from the I/O menu you are probably using the default I/O point in the example. It's usually necessary to choose the I/O point before running the example.
    Cheers.
    | Michael K | Project Manager | LabVIEW R&D | National Instruments |

  • The field point 4.1 software does not get installed, how to install the software and work on field point 20xx

    We want to know the basics of installation of field point s/w and where to start from after installation.
    Then we also need the details of HOW TO WORK in it. what are the other hardware and software that are necessarily to be installed along with field point in the PC. How to connect the hardware fp2000, to the PC.
                      Actually we tried installing the field point s/w, but we did not get the field point explorer icon to continue working.

    Hi.
    You can find informations in the NI Developer Zone (Distributed I/O -Fieldpoint)
    http://zone.ni.com/devzone/devzone.nsf/webcategories/67EFA8729F4A7741862567E1006EDA74
    and here for the Basics:http://zone.ni.com/devzone/conceptd.nsf/webmain/2124F6BBD29663D886256CB80054DBD7
    Configure your fieldpoint in MAX.

  • Hello, I have created a distribution kit for my program.The problem is that the when the program is installed onto another computer, it fails to communicate with field point (Using FP-AO-200 and FP-AO-1000). Help is greatly appreciated, Thanks faen9901

    Hi Everyone,
    I have a program that sends information(analog output) to lab windows cvi in the form of a text file or user input.
    The program runs on the computers that I have the field point explorer and lab windows cvi installed on. In order to run the program without always installing labwindows/cvi and field point; I wanted to create an executable file that could be load on another computer.
    I used the create distribution kit part of labwindows/cvi to do this.After creating the distribution kit, I then installed it
    to another computer.
    My user interface appears on the screen, when the user clicks on the exe. file, but no data is sent to the field point module. I know that the data is being read from the user and textfile because in it appears in the uir.
    The following are some details about the problem:
    1. On another computer without labwindows/cvi and field point explorer not installed - no data is sent to field point module
    I know this because a current is being read on the current meter connected to field point module.
    My questions are the following:
    1. What are the possible reasons for the data not being sent to the field point module?
    2. Do I still need to create an iak. (Installing Field point Explorer) file stored on any new computer that I install my created distribution kit file too?
    Thankyou very much for any help that you can provide. I greatly appreciate it.
    Faen9901

    Re: Hello, I have created a distribution kit for my program.The problem is that the when the program is installed onto another computer, it fails to communicate with field point (Using FP-AO-200 and FP-AO-1000). Help is greatly appreciated, Thanks faen9901Faen9901,
    1) If you do not install FieldPoint Explorer, the FieldPoint Server is not installed so there is nothing on the target computer that knows how to talk to the FieldPoint system.
    2) Yes, you need an IAK file on the target computer. Assuming the settings (i.e. com port#) are identical you can simply include the iak file as part of the distribution.
    3) You also need to include as part of your installer the file "fplwmgr.dll". If this file is not installed, your program will not be able to access the FieldPoint Server. Alternatively, this file is installed automatically if FieldPoint Explorer detects LabWindows/CVI or Measurement Studio Development versions on the target computer or if you choose to do a custom FieldPoint Explorer installation and
    choose to provide LabWindows/CVI support.
    Regards,
    Aaron

  • I have problem in transfeering data using field point via tcp

    I am reading the values from the filed point, which is connected, to the RT controller and transferring the values to the client PC via TCP at a specified acquisition rate.
     Case1 when the acquisition rate is 0.1 minutes I get the values from the controller correctly i.e. 5v, 5v, and the chart shows no change. The timed out of the TCP read is default value i.e. is 250ms
     But when I change the acquisition rate to .5 minutes I get the values as 5v, 0v, 5v, and 0v. The time out of the TCP read is same as first case. The inputs to the field point are at the constant 5v.
    Please tell how to solve the problem so as to see the plot in the chart continuously as inputs for the field points the read
    ing are at constant rate of input 5v.

    Suresh,
    Since this question deals with using the LabVIEW TCP/IP functions, you are better off posting it to the LabVIEW discussion forum.
    Regards,
    Aaron

  • Can FTP-access to field point log file interrupt the running program?

    Can FTP-access to field point log file interrupt the running program?
    We have a problem where our factory process control program on a Field Pointer suddenly stops the process. We are running the development system on a PC, wich deploys the program on the Field point, with user interface on the PC. Quite often the process stops for no apparent reason. I'm not sure right now if the control program on the Field Point is still running or if it stops. We use FTP from a distant PC (over VPN) directly to the Field Point to check if the process is running, by looking for date and size of log files produced during running process. I've never opened och copied any log file during process run, because this I'm sure this would cause problems for new log entries to be written. But can the mere looking at the log folder via XP-pros ftp-functionality cause the Field Point to have problems writing data to a log file?
    I'm not sure how windows XP pro handles "my network places" when it comes to FTP, it look that it keeps some kind of local copy of the folders, or at least the files opened.
    Next version of the program will have only basic functionality on the Field Point, leaving logging etc. to another program on the PC, but right now we are stuck with this system.
    Ola A

    It turned out that the problem lies in the harware of the production machine, it was not a labiew-program problem at all!
    Ola