ABAP SCREEN PAINTER DOUBT

Hi friends,
Any one can tell me the solution to resolve the error maximum number of internal sessions reached  .
regards,
p.varadarajan

Hi
Ossnote .... 34154 is very interesting.
This is concerned with internal sessions: The R/3 System offers the option to change from one information level to another: by branching in the menu path (for example "Goto" or "Information system"), double-clicking in ABAP lists, cross-references in hypertext and so on. Technically speaking, you call one program/transaction from within another one (ABAP/4 statements CALL DIALOG or CALL TRANSACTION, but not CALL SCREEN). For the user, it is desirable that this process is reversible, that is, that you can also go back step by step. The whole path is therefore stored in a stack of so-called internal sessions. If the maximum number of internal sessions is reached, you cannot go any further.
<b>This maximum number is hardcoded as 9, and this cannot be changed.</b>
Regards
Raj

Similar Messages

  • ABAP : Screen Painter error

    Hi Experts ,
    I need your help. Actually i have started working in ABAP as welll. need to know that below is the coding being done for Screen Painter and need your help  in troubleshooting error. the Error is :
    "Program ZSCREENPAINTER1
    "TYPE LINE" or "LIKE LINE" expected, not "BEGIN". ."
    coding that i have done is :
    PROGRAM  ZSCREENPAINTER1.
    DATA : OK_CODE TYPE SY-UCOMM,
    types: BEGIN OF EKPO,
           EBELP TYPE EBELP,
           BUKRS TYPE BUKRS,
           WERKS TYPE WERKS,
           MATKL TYPE MATKL,
           END OF EKPO.
    thanks & regards ,
    M.S

    just to add to all these answers..
    '.' (Dot) acts as end of statement in ABAP as ';' works for C..
    and ':'(colon) is used for  pipeline or chaining more than one statement.. and chained statements are joined using ','(comma)
    so
    left side : right side1,
                 right side2,
                 right side3.
    "this actually means..
    left side right side1. " ends here
    left side right side2. " ends here
    left side right side3. " ends here
    hope you understand now... its BASIC abap...

  • Screen painter doubt

    hi guys i am a fresher in abap and am havin a prob..
    wen makin the module pool program...
    i m addin two buttons to my screen painter..
    NEXT and BACK
    when in the module pool screen i am giving case n when statement it says case not defined and when i make a module for it in se38 it says for WHEN 'BACK'.. tat when should be followed by case..
    pl help

    Hi Abhi,
    Here you have to understand one concept, when you are clicking on Back or next pushbuttons it has to communicate the next action that you have given in the code that can be done using SY-UCOMM.
    If you declare Ok code in module pool elements than use OK_CODE.
    And you have to define your FCT code for Back and Next which will help you to trigger the action when button is click. Suppose double click on Back opens a window in that give fct code as BACK.
    Coming to code part.
    Case Sy-ucomm.
    When 'BACk'.
    Call screen 100.
    endcase.
    that means when i am clicking on back i am calling screen 100 understand the concept of your problem.
    Cheers!!
    VEnk@

  • ABAP : Screen Painter - Graphical layout

    Hi Experts ,
    I am doing an assignment for the screen painter. but when i click on the layout of it , I am not getting the graphical input. kindly advise. is there some new setting to made.
    thanks & regards ,
    M.S

    Hi M.S,
    If the setting is already check, then the problem is in GUI. While installing GUI there is a option for Screen painter. You need to check it at GUI inatall
    For patch details refer [Graphical Layout Editor|http://help.sap.com/saphelp_nwmobile71/helpdata/en/d1/801b77454211d189710000e8322d00/frameset.htm]
    Regards
    Edited by: Rajvansh Ravi on Nov 26, 2009 6:20 AM

  • Abap screen painter

    How to display negative values for a screen field on a screen.?

    Hi Kishore,
    Check out the link: To display negative value on the screen for amount
    Cheers,
    Brad

  • ABAP Dictionory type FLTP is nt allowed for  screen Painter!!

    Hello All,
    ABAP Dictionary type FLTP is nt allowed for  screen Painter!!  am getting this error message if am giving some input.
    Thanks
    santu
    Edited by: santu4u on Oct 23, 2009 1:48 PM

    Hi
    Instead of FLTP use Quantity or Currency or Packed Decimals type fields for the Screen Elements.
    While you save the data into the database if the database field is of type FLTP the values entered would be automatically converted into FLTP type. We need not take care of this.
    ---?? What do you mean by IDES version --->
    You mean in SE11 or SE16, Wherever it may be you can not use FLTP type on Screen Fields.
    This is Standard SAP Procedure, As mentioned Above you can use Packed Decimals or Currency or Quantity Fields
    Cheers
    Ram
    Edited by: Ramchander Krishnamraju on Oct 23, 2009 2:10 PM
    Edited by: Ramchander Krishnamraju on Oct 23, 2009 2:13 PM

  • Passing the values from selection screen to screen painter

    Hello Friends,
    I'm making one report program in which im calling  one screen which i have designed, in my selection screen there is a select option for customer  tht accepts value range now i want to select all the customers entered in select options and pass these values in screen(screen painter).
    pls guide me how this can be done.
    Regards,
    Sunny

    Screen painter is a tool in ABAP dev workbench used to create the screens using the
    T-code SE51. In the screen painter, you can define the following interface elements with their associated attributes.
    1. Input/Output Fields
    2. Field Names
    3. Checkboxes
    4. Radio Buttons
    5. Group Boxes
    6. Sub screens.
    7. Pushbuttons with No Fixed Position
    Create a Z program in tcode SE38.
    Go to transaction SE51.
    Enter the created program name and screen number.
    Click on flowlogic tab. 
    Uncomment the statement u201C MODULE STATUS_0100 u201C. 
    CASE SY-UCOMM.
        WHEN 'EXIT'.
          LEAVE PROGRAM.
        WHEN 'BACK'.
          LEAVE PROGRAM.
        WHEN 'DISPLAY'.
          SELECT SINGLE Fileds to selsct
               INTO (interanl table or tablename-fileds)
          WHERE Condition.    WHEN 'CLEAR'.
          CLEAR table.
      ENDCASE.
    ENDMODULE.

  • Regarding the flow logic in screen painter

    Hi Experts
    I am a BW guy and i am new to ABAP and i need your help to solve my problem.
    I have created a table for master data(zemp_data) in R/3 se11..which has fields like zempid,zempname,zmgrid,zdeptid,zdeptname and i have created the respective fields in screen painter too but my problem is i dont know how to link this fields  in the screen painter to the  fields in table .to be more clear i want the flow logic or module pool code to link this table when i give an entry in the screen painter for the respective  fields..i will really appreciate your answers and award the maximum points for the usefull answer ..as i dont know ABAP much if it is a step by step approach ..that would be helpfull
    Regards,
    RK.

    Hi Karthik,
    Please consider the following
    In the screen...the fields must be from the database table in Se11..(in screen painter -> use.."get from Dictionary" -> enter the table name -> select the fields -> drag and drop on the screen) or must have the same name in the database table..This will be a link but unless you code to fetch values from database or update values to database there will be no action taking place
    Usually in the PBO(process befor output) we write the code to display values before we accept data from the user ie,set default values on the screen if required and prepare the screen for user input
    in the PAI of the screen painter we can do data processing ie, data validations,checks and saving based on what the user wants
    So imagine you have buttons placed on the screen and there are buttons from standard application bar like BACK,SAVE, set using PFstatus..all the user actions will be linked to a function cod..ie whenever user presses a button we can uniquely idntify what was pressed by assigning a function code to each button in the menu painter or PF status and do the action accordingly
    Assume that you have created a push button on the screen painter and assigned it a function code "PUSH"
    so whenever you press the button in the variable sy-ucomm "PUSH" will be captured..this you can check in PAI for the screen like
    Case sy-ucomm.
    when 'PUSH'.
    do the needful coding
    when 'SAVE'
    Modify database table
    endcase.
    you can check the standard demo programs in SE38 -> program name-> display for basic ABAP coding you have asked for
    (1)demo_dynpro_input_output .
    (2)demo_dynpro_dictionary
    (3)demo_dynpro_push_button
    Pls let us know if you need more help on the same
    Reward if helpful
    Regards
    Byju

  • How to set Function Code for Radion Buttons in Screen painter

    Hi,
    I have faced problem of grouping 3 radio buttons in screen painter (no graphical editor). How to do it?
    I have checked similiar threads in SDN, but those are for graphical editor.
    Radio Buttons in custom screeen
    http://****************/Tutorials/ABAP/Checkbox/page1.htm
    http://****************/Tutorials/ABAP/Checkbox/page2.htm
    Regards,
    Sukhbold

    Hi,
    U want to create radio button in the selection screen  then u can create like this
    PARAMETERS : c1 AS CHECKBOX USER-COMMAND cd,
    r1 RADIOBUTTON GROUP rad,
    r2 RADIOBUTTON GROUP rad.
    AT SELECTION-SCREEN OUTPUT.
    IF c1 = 'X'.
    LOOP AT SCREEN.
    IF screen-name = 'R1'.
    screen-input = '0'.
    screen-active = '0'.
    MODIFY SCREEN.
    ENDIF.
    ENDLOOP.
    ELSE.
    LOOP AT SCREEN.
    IF screen-name = 'R1'.
    screen-input = '1'.
    screen-active = '1'.
    MODIFY SCREEN.
    ENDIF.
    ENDLOOP.
    Thanks,

  • SCreen Painter working not correctly.

    Hi,
    In se53 when we go to screen painter it's not coming properly..
    some line is coming.
    and we got EU_SCRP_WN32 : timeout during allocate / CPIC-CALL: 'ThSAPCMRCV'  error message.
    we have sap gui 710 with patch level 7.
    the dumpfile also generated.
    Runtime Errors         STORAGE_PARAMETERS_WRONG_SET
    Date and Time          22.07.2008 12:44:27
    Short text
    The system is configured incorrectly.
    What happened?
    The current program had to be terminated because of an
    error when installing the R/3 System.
    The program had already requested 453411792 bytes from the operating
    system with 'malloc' when the operating system reported after a
    further memory request that there was no more memory space
    available.
    What can you do?
    Note which actions and input led to the error.
    For further help in handling the problem, contact your SAP administrator
    You can use the ABAP dump analysis transaction ST22 to view and manage
    termination messages, in particular for long term reference.
    In the system profile, set the parameters
    -abap/heap_area_dia and
    -abap/heap_area_nondia
    to a maximum of 453411792. To be on the safe side, reduce the value by 10,000,
    000.
    Then restart the SAP system.
    Error analysis
    When the program was running, it was established that more
    memory was needed than the operating system is able safely
    to provide. To avoid a system crash, you must prevent this
    situation from occurring.
    Last error logged in SAP kernel
    Component............ "EM"
    Place................ "SAP-Server mtw02sdec01_DE7_00 on host mtw02sdec01 (wp
    1)"
    Version.............. 37
    Error code........... 7
    Error text........... "Warning: EM-Memory exhausted: Workprocess gets PRIV "
    Description.......... " "
    System call.......... " "
    Module............... "emxx.c"
    Line................. 1881
    The error reported by the operating system is:
    Error number..... " "
    Error text....... " "
    How to correct the error
    Report the error to the group responsible for installing your
    R/3 System.
    Please help.
    regards
    deepak

    Dump is telling you what to do...
    Review abap/heap_area_dia and abap/heap_area_nondia
    I presume you try that before posting right?...
    Whats the issue then?
    Regards
    Juan

  • Having Problems with my Screen Painter

    Hi,
    I'm new to SAP and I'm still learning. I'm on this part of tutorial wherein I am trying to create a Screen using the Screen Painter. But the problem is, the interface of SAP in the book looks something like this:
    http://www.kodyaz.com/articles/sap-abap-tutorial-alv-grid-cl_gui_alv_grid-screen-painter.aspx
    But my interface looks different. I'm sorry I can't post the picture here but It can be well described. It looks like a "notepad" with horizontal lines.
    Has anyone encountered this kind of screen painter? Hope someone could help me.
    Thanks.

    Hi,
    Do you receive some error like 'Graphical Layout Editor not available 37527'. Does the problem occurs only for some users or for all the users?
    If the issue is for all users, I suggest to check notes 101971 and 204910.                                                                               
    If its for a particular user, please make sure "graphical layout editor" is checked under SE51->munu Utilities/settings->tab ScreenPainter.           
    Hope this info helps,
    Br,
    Javier

  • Screen painter is not working properly.

    Hi,
    when i execute se51 the screen painter is not coming properly.
    some dotted line coming and throughing the below message.
    EU_SCRP_WN32 : timeout during allocate / CPIC-CALL: 'ThSAPCMRCV'
    i am using sap gui 710 final release with patch 7.
    can plz suggest wht should be the problem.
    Regards
    deepak

    Hi Deepak,
    As Ashutosh said, please post the thread in the ABAP forum. Do not create a new one.
    Moderators,
    Please move this thread to ABAP forum.
    For the time being, refer the notes: [204910|https://websmp130.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/sapnotes/index2.htm?numm=204910], [885581|https://websmp130.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/sapnotes/index2.htm?numm=885581] and [101971|https://websmp130.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/sapnotes/index2.htm?numm=101971]
    Regards,
    Srihari

  • Report  and SAP-SCRIPT  &  SCREEN PAINTER

    Hi all ,
      I need some help.
    1)How to transport sap-script.
    2) print program of sap script are client-dependent or client-independent.
    3)Database tables ( on se11)  are client-dependent or client-independent. ( is sy-mandt will make dependent or independent)
    4) how to create select-option on screen painter or with module pool programming.
    5)performance tuning for ABAP report.
    points for all answers assured.
    thanks.

    Ihave some notes on transporting sapscript for earlier version of SAP. 
    The steps may vary based on your version and Suppport PAckages levels. 
    In the future your version and platform detials will help in a quicker response.
    Summary of sapscript EXPORT / IMPORT process.
    Steps to export Layout Sets (sapscript)
    Log on the Source system and client
    This may have to be client 000 and then again in the client in which you do developement.
    Note that sapscript is client dependent
    SE38 and execute program RSTXR3TR
    Tranport number: DS1K9#####
    Mode field: EXPORT
    File system: Server -  radio button
    The dataset name: /usr/sap/trans/data/DS1K9#####.layoutsets
    CHECK the Display dataset contents checkbox
    Execute
    Steps to import Layout Sets (sapscript)
    Log on the target system and client.  This may have to be client 000 and then in the client in which you test, or ultimatly production.
    SE38 and execute program RSTXR3TR
    Tranport number: DS1K9#####
    Mode field: IMPORT
    The dataset name: /usr/sap/trans/data/DS1K9#####.layoutsets
    CHECK the Display dataset contents checkbox
    Execute
    Note: when importing into Production, the export does not need to be performed. 
    Therefore only the import protion is required once the sapscript has been exported from Development.

  • How to set default values on the screen painter parameters?

    Hello ABAP Gurus,
    I would just want to ask how to set default values on the screen painter parameters.
    Thank you for your replies.

    Hi,
    To set default values for screen painter parameters initialize the field names with default values in the PBO module....
    say u have the field name as f_field1....
    in the PBO of that screen initialize it....
    f_field1 = '100'  "here 100 is the default value.
    <b>reward points if useful.</b>
    regards,
    Vinod Samuel.

  • Table view control problem in screen painter

    Hi All,
    i am unable to display the contents in the table view control in screen painter....actually i have created two screen one to take input and second to display details on next screen in table view control..but i m nt getting that details...
    my second screen PBO/PAI code is
    PROCESS BEFORE OUTPUT.
    loop at itab with control TCNTRL CURSOR tcntrl-current_line.
    MODULE STATUS_0101.
    endloop.
    PROCESS AFTER INPUT.
    loop at itab.
    endloop.
    MODULE USER_COMMAND_0101.
    can anyone solve my problem????????
    Thanks,
    Jayshree

    Hi,
    Use below approch (syntax may not be correct as I have typed it in notepad but use it as guide line)
    ***In screen flow logic
    PROCESS AFTER INPUT.
      module cancel at exit-command.
      chain.
        field: zproject_details-originator,
            zproject_details-proj_type.
        module check_data on chain-request.       
      endchain.
      module user_command_002.
    ***In abap code
    module cancel input.
      leave program.
    endmodule.
    module check_data input.
      if zproject_details-originator is initial.
        message exxxx "throw error message here
      endif.
      if zproject_details-proj_type is initial.
        message exxxx "throw error message here
      endif.      
    endmodule.
    module user_command_002.
      save_ok = ok_code.  "good practice to save okcode
      clear ok_code.
      case save_ok.
        when 'save' " using constant for fcode here is better
          perform save_data. "make it moduler instead of writing whole code in case statement
      enscase.
    endmodule.
    form save_data.
    ** do some additional checks if required before saving
    update zproject_details from zproject_details. " update database table here from work area contents
    endform.
    Regards,
    Vishal

Maybe you are looking for