Agilent Technologies 54200A Oscilloscope LabVIEW 8.2 driver

 Hello: I need LabVIEW 8.2 driver for HP 54201A DSO
Regard fahim

http://www.ni.com/downloads/idnet/
I'm sure you're more than capable of typing "54200" into the search box.
Also, from within LabVIEW,  Help -> Find Instrument Drivers.

Similar Messages

  • Agilent Technologies 2000 3000 X-series Driver Example Timeout

    I am running the example VIs, "Acquire Waveform.vi" and "Acquire Waveform Continuously.vi," that come with the Agilent Technologies Oscilloscope driver "Agilent 2000 3000 X-series."
    While my issue and attempts at dealing with it are detailed in the attatched pdf, I will outline them here. When I run either of these example VIs, the initalize the scope without error, and they succesfully run the Auto setup VI, but whenever the VI attempts to read data from the scope, it exceeds the maximum allowed time for any reasonable value I input. I get the following error:
    "Error 1073807339 at VISA read in Agilent 2000 3000 X-series.lvlib: wait for acquisition complete.vi->Agilent 200300 X-series.lvlib: read wave forms (single).vi-> 2000 3000 X-series Acquire save forem.vi
    Possible reasons: VISA (Hex 0xBFFF0015) Timeout expired before operation complete"
    I ran the VI with several inputs for maximum time, starting from 1ms and working my way up to 1,000,000ms. I get the same error for all of these except the longest time, in which case the error reads "The connection for the given signal has been lost" (not surprising, 16 minutes is a long time)
    Additionally, I have to power cycle my scope to regain control after running this VI. I assume (hope) that this is a related issue and once the VI no longer times out, the scope will function normally.
    I have looked through the existing forum posts related to this and found a few that weren't close enough or weren't answered satisfactorily, however, if you think I have missed something in that regard, please feel free to tell me or post a link to that particular thread.
    Any tips tricks and advice would be greatly appreciated and kudos will be given to helpful posts.
    Other information:
    Labview version 13
    VISA verions 5.4
    OSX verison 10.7.5
    Link to driver:
    http://sine.ni.com/apps/utf8/niid_web_display.download_page?p_id_guid=9E84674573AF6AB8E0440021287E6A...
    Solved!
    Go to Solution.
    Attachments:
    labviewnotes.pdf ‏1240 KB

    Thanks. You don't have a complete communication failure then.
    I know I've used this scope and driver without any problems but the interface was probably GPIB. The USBTMC driver is supposed to emulate the GPIB protocol. I don't know if the issue is with agilent's implementation or something else. I would first make sure you have the latest driver and firmware from them. I would then try it on a Windows machine. Maybe someone else has other ideas.

  • [BUG] Agilent ESA PSA Series LabVIEW driver for Models E4401B and E4402B

    Agilent ESA PSA Series LabVIEW driver are not working with Models E4401B and E4402B.
    Driver Version 2.1.1
    LabVIEW: 2009
    Web Link: http://sine.ni.com/apps/utf8/niid_web_display.download_page?p_id_guid=309EBE8FF8BC0E76E0440003BA7CCD...
    Problem: ID Query in "Agilent ESA PSA Series.lvlib:Initialize.vi". ID Answer from Instrument is not match with strings in Match Array. Somebody left whitespace at the strings end. ("Hewlett-Packard,\sE4401B\s" and "Hewlett-Packard,\sE4402B\s").
    Everything else is working well.

    Hi JCC,
    Thanks for bringing this to our attention, a Corrective Action Request has been created: CAR - Corrective Action Request - #247239 and a member of R&D will take a look into this to get the issue resolved.
    Kind Regards,
    Applications Engineer

  • Help file for the Plug and Play driver of Agilent Technologies E5071C

    I just download the Plug and Play driver of Agilent Technologies E5071C from the below link:
    http://sine.ni.com/apps/utf8/niid_web_display.model_page?p_model_id=5692
    I find that there is only some examples and not any help file with detail description for each input of those VIs. Although there is brief description for each VI when I press "Ctrl+H" on the VI,I still can't figure out how to use this driver. :-(
    Is there any help files with more detail description?
    Or any related examples for my reference? I hope to measure the S11 and S21 of the SMA cables

    The driver implements the commands defined by agilent.
    So look in the agilent programmers manual to find the meaning and how to handle the instrument.
    greetings from the Netherlands

  • Agilent 33220a labview 7.1 driver

    Hi,
    I want to ask LabVIEW 7.1 driver for Agilent 33220A. I installed 7.0 and as a result it doesnt work.
    Can somebody help me about this matter
    Thanks a lot

    thank you very much for your quick answer,
    After  I installed driver to the int.library, the blocks of the driver doesnt seen as seen in the attached.
    Attachments:
    hata.JPG ‏40 KB

  • Unterminated errors using NI's IVI (AG6000) with Agilent's DSO5054A Oscilloscope

    Hi,
    I keep getting timeout errors when using the IVI file ag6000 with Agilent's DSO5054A Oscilloscope over GPIB.  Using TestStand, I am able to calibrate the o-scope about 50-60% of the time and read from the o-scope about 2% of the time.  When sending a command using the IVI, the o-scope typically displays "query UNTERMINATED."  Attached is the error TestStand gives when it is not able to talk correctly.  In MAX, I can talk to the o-scope using the GPIB communicator tool 100% of the time.
    Is there an updated version of the ag6000 IVI file that works with the DSO5054A that I don't know about?
    Thanks.
    Attachments:
    Common Error.JPG ‏115 KB

    I believe I am giving enough time for the commands.  What I meant was that I know the NI GPIB card is good, the cable is good, and the o-scope is good, it is just the o-scope just does not like the signals sent using either the LabVIEW LabWindows/CVI Measurement Studio for Visual Studio IVI or the LabVIEW Plug and Play driver.  The site takes me from the DSO5054A page to a 6000 series driver, although according to the description it should work with the o-scope.
    http://sine.ni.com/apps/utf8/niid_web_display.model_page?p_model_id=10028
    Using the above IVI/Plug and Play drivers, the DSO5054A reads the correct signal but unterminated, so it doesn't know what to do half the time.  In TestStand, I added in the initiate command and added a wait of 10 seconds, and when it doesn't timeout on the calibrate command it will timeout on the fetch/read command.  In LabVIEW, using the read single waveform.vi the GUI displays the signal from the o-scope about 10% of the time, while the rest of the time it times out with error code -1073807339.

  • Dso1022a (LabVIEW 7.1 driver?)

    Please let me know if my driver can be converted for use with LabVIEW 7.1.
    Thank You.
    Instrument - Agilent DSO1022A Oscilloscope (USB connection)
    Source driver written for LabVIEW 8.2
    Request resulting driver compatible with LabVIEW 7.1
    Solved!
    Go to Solution.
    Attachments:
    agilent_dso1000_series.zip ‏784 KB

    try the attached
    Attachments:
    Agilent DSO1000 Series 7.1.zip ‏687 KB

  • Agilent 33250 vi for labview 6.1

    Hi i need agilent 33250a vi for labview 6.1

    There is an instrument driver on the Instrument Driver Network but it will support LV7.0. Since the driver is supported by NI you can make a request through support to let them convert it for you to LV 6.1
    Message Edited by waldemar.hersacher on 10-23-2008 12:50 PM
    Waldemar
    Using 7.1.1, 8.5.1, 8.6.1, 2009 on XP and RT
    Don't forget to give Kudos to good answers and/or questions

  • Unable to load LabVIEW RT from drive

    Trying to boot RT on PXI-8187 controller with original setup, what ever RT boot selection is used either hardware switch or BIOS RT boot option, the terminal will show the following:
    Unable to load LabVIEW RT from drive!
    Booting safe mode from ROM...
    mount: Mounting /dev/Ma1 on /home/ftp/c failed: Invalid argument
    Entering safe mode.
    IP address is: 0.0.0.0
    Of course after that you can't do any thing to configure the RT target from the MAX on the host computer.
    Please Help.

    Hi,
    I used the recovery CD to change the file system to NTFS, it took a while and it installed windows XP from scratch differently from FirstWare that ghosts it (I think). And it didn't install any NI stuff what so ever.
    At the end I got the same result as with using the remote system format disk option.
    i.e. The RT controller boots in safe mode displaying the previous message without the mount error but this time I can configure the IP address.
    Still I can't install software to it, I get the list of features to install, I select them and press next, then I get a dialog saying:
    Cannot process install because other dependencies are required:
    LabVIEW RT 1.0.1
    LabVIEW RT 6.0.1
    LabVIEW RT 6.1.0
    LabVIEW RT 7.0.0
    LabVIEW RT 7.1
    Is this a host or RT Controller issue now?
    What's next? Thanks for the help

  • Labview 6 compatible driver for HP89410A Vector Analyzer

    Does anyone know where I can get a labview 6 compatible driver for an HP89410A Vectory Analyzer?
    I have found labview 7 and labview 8 drivers for the hp894xx family of devices, however I cannot use them as I only have labview 6.
    Barring a prewritten driver, how hard would it be to convert a labview 7 driver to make it compatible with labview 6?

    The conversion is easy since there is a VI Tree VI in the driver. Since the driver was originally written in 1999 and has been up-converted to 7.0 and 8.0, saving it back down to 6.0 shouldn't be an issue.
    Attachments:
    hp89400_6.zip ‏1194 KB

  • LabVIEW 2010 FPGA Driver for Xilinx SPARTAN 3E Starter Board

    Dear Friends,
    Is there any possibility to release a LabVIEW 2010 FPGA Driver for Xilinx SPARTAN 3E Starter Board?
    Regards,
    wedo
    Solved!
    Go to Solution.

    Hi Brad,
    So glad to get your post here!
    I’m looking forward to download the new installer.
    I wonder whether the new driver will support the 10/100 Ethernet Physical Layer Interface, since the last drivers aren’t support this feature!?
    Also, will be any new examples included with the new driver? For instance: an example for the StartaFlash Memory; I have done an example for this but I couldn’t get it work! I don’t know why! You may check my post and the example in the following link!
    http://forums.ni.com/t5/LabVIEW/Spartan-3E-StrataF​lash-Memory-wrong-reading/m-p/1030898
    By the way, is there any plane to develop a driver for the Spartan-3E (1600Kgate) kit? Both kits (500KGate and 1600KGate) have the sample on-board peripherals, the only difference is in the number of Gates (FPGA chip). I think all that is needed is to add the component ID (29597843---->3E1600) and revise the xc3s1600e.bsd and 3sXXXe.nph.
    Thanks in advance & kindest regards,
    wedo

  • Piloter Agilent 33120 A depuis Labview

    Hello,
    I have to pilot a multimeter Agilent 33120 A with Labview and my problem is that I downloaded drivers here :http://sine.ni.com/apps/utf8/niid_web_display.download_page?p_id_guid=E3B19B3E9066659CE034080020E748...
    I tried to test one of the example given with drivers but it doesn't work, does anybody has an idea of the problem?
    Do you think it could be about the interface because i'm using a RS 232 wire and I didn't see this type of interface in the suggested interfaces on the website i gave by the link.
    Thanks

    Attachment
    Attachments:
    printscreen2.pdf ‏253 KB

  • Intel Rapid Storage Technology with a single mechanical hard drive.

    Do you recommend installing Intel Rapid Storage Technology with a single mechanical hard drive.
    MSI website suggest these IRST drivers for my motherboard:
    - Intel Rapid Storage Technology Driver
    - Intel Rapid Storage Technology Floppy Driver for 7x series
    - Intel Rapid Storage Technology Driver for 7x series
    Board: MSI Z77A-GD55 LGA 1155 Intel Z77 HDMI SATA 6Gb/s USB 3.0 ATX Intel Motherboard with UEFI BIOS
    Hard Drive: SAMSUNG Spinpoint F3 ST1000DM005/HD103SJ 1TB 7200 RPM 32MB Cache SATA 3.0Gb/s 3.5" Internal Hard Drive
    Multiple responses/opinions is encouraged for complete verification.
    Thanks!

    Hi,
    Sorry to dig up this thread.
    This is from Z77A-G45 driver page:
    1. Intel Management Engine Driver
    2. Intel Rapid Storage Technology Driver
    3. Intel Rapid Storage Technology Floppy Driver for 7x series
    4. Intel Rapid Storage Technology Driver for 7x series
    http://www.msi.com/product/mb/Z77A-G45.html#/?div=Driver&os=Win7%2064
    Like BiGxSHOOTER, I have a single drive and I don't know the importance of each driver. Can someone tell me which ones I should install and in what order?
    Thanks

  • Using HP 548xxa oscilloscope LabView driver to generate csv files

    I have downloaded the HP 548xxa Oscilloscope driver. I'm not sure how to use the driver so that I can capture waveforms and generate a CSV or fext file of the waveform data

    To understand instrument drivers, you should start by reading chapter 16 of the LabVIEW Measurments Manual. This is a shipping document that you can access from Help>Search the LabVIEW Bookshelf. Your specific driver comes with a VI called hp548xxa Getting Started. This is a high level example that demonstrates how the subVIs in the driver can be used. You should look at this first and get this working. The actual subVI that gets waveform data is hp548xxa Data Read Waveform. This returns a single channel's data as a 1D array and x scale information (timing) as scalars. You can wire this data to Write to Spreadsheet File or create a waveform data type for each channel acquired and use Export Waveforms to Spreadsheet File. The attached example demonstr
    ates this method. Hope it helps.
    Attachments:
    Scope_to_Spreadsheet.vi ‏49 KB

  • Configure Agilent E8408A mainframe in LabView

    How do I configure an Agilent E8408A mainframe with Agilent E8491B IEEE-1394 VXI card and Agilent E1419 Multi-Function (Option 011) so that Labview can recognize it?

    tanonev,
    You can use VISA or the instrument driver you found to communicate with your instrument. Both will work just fine. Usually Instrument drivers are created because they simplify the tasks and allow you to perform common tasks for your device. VISA will allow you to send and receive commands to you device, usually these commands can be found in the manual for your device. This tutorial may help you understand how to use VISA and instruments Drivers better.
    http://zone.ni.com/devzone/conceptd.nsf/webmain/1b247c334745c03f8625694d0045c63c?OpenDocument
    Shawn B.
    National Instruments
    Use NI products on Linux? Come join the NI Linux Users Community

Maybe you are looking for

  • Where can I get an original x58 Pro-E IOH chipset heatsink assy?

    Recently built an i7 gaming rig and like everyone else had high nb temps which I'm not very keen on. I had a Thermalright HR-05 from another build (took it out of my old system and replaced it with the original HS and sold that PC leaving me with it)

  • Save as Adobe PDF opens the wrong installation of AA

    Hi all, I bought an Adobe CC membership and after a month I found out that my apps were expiring. I accidentally set CC on Dutch (native language) but I ordered the English version. No problem, deinstalled all the apps and reinstalled them in the Eng

  • Final Cut Pro X crashes on export

    I chose to ignore the overwhelming negative discussion that has surrounded FCP X and decided to purchase and learn the program early. I went in with eyes wide open hoping I could learn quickly and start turning out video's as good or better than we'r

  • Open note for S_ALR_87008272 using program RKAZUTR1

    Hi Experts, Please provide open note for S_ALR_87008272 using program RKAZUTR1, to run S_ALR_87008272 in Quality and Production client. Thanks Neeraja

  • I have downloaded flash player many time will not complete download.

    I have tried to download many, many, times to download the latest version of your flash player!!!  I have called geek squad to help me fix the problem.  It still has not been resolved.  I have visited you trouble shooting sites and followed all steps