I'm pretty new to LV all together, but I'm working on writing a program to monitor information off our CAN network, like oil pump speed, water temp, batt voltage, etc.  Is there a way to monitor these signals using the frame api, opposed to channel api, and display them continuously on a gauge/meter?  Since I'm using PDA module, I have to use the frame api, and not channel.  Frame api seems a little more vague to me than channel api.  Any advice or tips are welcome.
Also on a side note, I copied/pasted a tab that i changed the background color to yellow from a windows targeted program to a PocketPC one.  The tabs stayed yellow when I built and transfered the .exe to the pda, but i don't have any control now on its color because PDA module doesn't have Property Nodes.  Every now and then, the tabs will go to default grey, and i have to undo the changes to get it back to yellow.  Is there some way to control the color?  I don't think the Change Control Color works in this case.
Thanks ahead for any comments and advice.

....By the way, i'm using a PCMCIA-CAN/2 (HS) card on a PDA running WinCE5.0 and soon to be one running WinCE4.2...

Similar Messages

  • CAN periodic transmit message with different modes using Frame API's

    I want to transmit a CAN message periodically using Frame API's. I am able to send messages which dont have modes inside the message. For some messages having multiplexer in ".ncd " files and inside that multiplexer having different modes. Now in order to send all the modes of that message periodically by configuring them once by using Frame API's i did not  find a way. I am able to send messages but the last updated mode is only sent periodically. Is there any way that CAN message having different modes can be sent periodically, updating all modes periodically automatically using Frame API's.

    Hello Kpraveen,
    You could set the period for N*Period, N being the number of modes.  You just need to make sure your application changes the modes fast enough to update each periodic frame.
    For example, say you have 2 modes and the frame's period should be 10ms.  That means that you would like that frame to go out twice every 10ms, updating mode 1 and then mode 2.  So, that means that the frames period can be 5ms. 
    1.  It will start by updating mode1
    2.  5ms later, it will update mode2
    3.  5ms later it will update mode1 again
    mode 1 really has a  period of 10ms...
    You just have to make sure that you can update the frame fast enough, or switch between modes fast enough, or you will send the same mode twice.
    Let me know if this helps, or if I an not understanding this properly.  Have a great day.
    O. Proulx
    National Instruments
    www.ni.com/support

  • Please Help.  How can you monitor a directory using jndi connection to a ldap server?

    How can you monitor a directory using jndi connection to a ldap server? I
    want the ldap server to monitor the content change in a file system
    directory on another computer on the network. Can someone please help.
    Thanks
    Fred

    Hi,
    Why do you want to use LDAP for Hard disk monitoring..???
    U can do this by creating a MD5 checksum for all the files existing in some
    perticular
    directory and every hour or any configurable period u can recalculate the
    checksum
    to find out the change in the content.
    I guess all u need is to get the code for "updatedb" utility of Linux and
    instrument it for ur needs..
    Hope it helps...
    -aseem
    mr wrote:
    How can you monitor a directory using jndi connection to a ldap server? I
    want the ldap server to monitor the content change in a file system
    directory on another computer on the network. Can someone please help.
    Thanks
    Fred

  • Can you Monitor an ONS 15454 with Mars?

    Can you Monitor an ONS 15454 with Mars?  Is there a specific "Device Type" to use in order to do this?

    ONS 15454 is not a supported device on MARS.
    Here is the supported platform on MARS for your reference:
    http://www.cisco.com/en/US/docs/security/security_management/cs-mars/6.1/compatibility/local_controller/dtlc6x.html
    Hope that helps.

  • Printing from iphone 4s, can you print without using airprint enabled printers

    printing from iphone 4s, can you print without using airprint enabled printers?

    There are other apps that allow printing to various apps.
    I use ePrint; works great for my work and home printers.

  • HT3819 Can you share photos using home sharing?

    Can you share photos using home sharing?

    You can't use homesharing, but you can use the iCloud Photo Stream to do something similar : http://support.apple.com/kb/HT4486

  • I have an Apple Cin HD Display 23" monitor, purchased in 2006.  I use it with a old PC (2007) running Win XP.  Works fine.  Can this monitor be used with a new PC with Intel 4th gen i5 processor, running Win 8.1?

    I have an Apple Cin HD Display 23" monitor (part no. M9178LL/A), purchased in 2006.  I use it with an old PC (2007) running Windows XP.  Works fine.  Can this monitor be used with a new PC with Intel 4th gen i5 or i7 processor, running Win 8.1?

    I have an Apple Cin HD Display 23" monitor (part no. M9178LL/A), purchased in 2006.  I use it with an old PC (2007) running Windows XP.  Works fine.  Can this monitor be used with a new PC with Intel 4th gen i5 or i7 processor, running Win 8.1?

  • Can you explain when using keywords and addding them to various clips pressing ctrl and a number eg. 1 or 2 it simply closes down FCPX.  Just to the dock as would th yellow -sign. As you gather I am new to this program having only used Final Cut Express 4

    Can you explain when using keywords and addding them to various clips pressing ctrl and a number eg. 1 or 2 it simply closes down FCPX.  Just to the dock as would the yellow -sign.  I am new to this program having only used Final Cut Express 4 previously.
    iMac (early 2009) 24in 2.93GHz 4GB 1066MHz DDR3 SDRAM (To be upgraded ot 8GB in the nextfew days) os x 10.7.2 Lion
    Re: Why don't my arrows on the time line operate and allow me to move to the start and end of the timeline. Iam using the trial version 

    Check System Preferences. I think Control-1 is used by something in the OS now. Switch it off. It's a major p[ain the way the OS is taking over more and more of the keyboard, allowing less options for application use.

  • Can you download and use iphoto on a pc

    Can you Download and use iphoto on a PC

    iPhoto is only available for the iPhone, iPad, iPod touch and Mac, so you can't install it on a PC

  • Can you boot up using time machine

    can you boot up using time machine? have continuous grey screen at startup.

    Time Capsule TC = hardware router and hard disk designed to work with Time Machine.
    Time Machine TM = software in the computer designed to run background backup.
    What you buy is a Time Capsule..
    And yes, that is the whole point of the TC..
    Its fundamental design is a backup device for laptops over wireless so they do not need to be plugged in to do backups.
    You are using it exactly for the intended use.

  • Thinking of purchasing EA6500. Can it monitor bandwidth use by device

    I'm thinking of purchasing a Cisco Linksys EA6500. I need a router that can one monitor bandwidth used by device. Keep exceeding our ISP's network bandwidth allocation, need to identify the devices that are causing this high usage and be able to do so from the router. Does the EA6500's standard software support this, is their router software one can obtain for the unit that does this or is there another home router option that can perform this function? Stephen, Madeisky

    If I were in your shoes, I would find a router that supported it. Linksys routers aren't designed and marketed for stuff like that.
    As was previously said, netgear routers are the only ones that I'm aware of that do that. But there could be others.
    Check here:
    Www.smallnetbuilder.com

  • CAN Read using Frame API

    I'm working with raw CAN data. The protocol sends out response as raw bytes(8 or upto 30)  on CAN Bus when data is requested by a CAN message.
    Example:
    Tx : Message ID with number of bytes you want to receive
    Tx   12X   30 00 00 00 00 00 00 00
    You'll receive the requested 30 bytes (only once) in this format
     22 00 00 00 00 00 00 00
     23 00 00 00 00 00 00 00
     24 00 00 00 00 00 00 00
    I started working using the Transmit Receive same Port.vi in the examples modified it to suite my application.
    I changed the Vi to identify the 24 as the last byte and stop the Vi or wait 1/2 sec if it does not find any data.
    The Problem:
    The Problem I'm facing is sometimes the Vi is missing reading the data and runs for 1/2 sec and shuts off. I am using other trace tools to make sure the desired data is on the bus.
    If I run the Vi 10 times the Vi would miss reading the data atlest 4 times. Since the data is received only once after the request it is important to read immediately after the write.I'm posting the code and help to improve the read process would be appreciated.
    Attachments:
    Transmit_once_Receive_Multiple_Msgs.vi ‏99 KB

    Hi Vamsi,
    If your NI CAN card has 2 ports, you can use the bus monitor to check that the data on the bus is seen by the NI CAN card (you had mentioned that you have other trace tools, but this will make sure that the NI CAN card is reading the bus properly).  You can learn about the bus monitor:
    How Can I Monitor the NI-CAN Bus?
    Using the NI-CAN Bus Monitor Without Going Through MAX 
    To troubleshoot your code, you can use indicators and probes on your String wires at various pointsto make sure that the frame data looks like you expect as you're parsing it.  
    Mark E.
    National Instruments
    Schedule a Free 1-Hour online LabVIEW Tutorial with an NI Applications Engineer

  • How to do frequency division to a external signal use the api with vc

    i use the api and vc do frequency division.
    and i choose the function DAQmxCreateCOPulseChanTicks
    the problem is the parameter of sourceTermianl in DAQmxCreateCOPulseChanTicks
    i just do not how to use it, please help me ,thanks

        I can`t see your VI cause i've a lower version. I hope this VI to do what you want. 
    But now i have one question: Somebody knows why i get this message when i enable the disable diagram of the this vi? The message is attached, version is 8.0, winxp.
    Paul
    Mechatronic engineer
    Lima-Perú
    Attachments:
    FOURIER_TIME_SCALING.vi ‏25 KB
    msg.JPG ‏31 KB

  • Can we monitor SM35 using CCMS

    Can we monitor, SM35 transaction by configuring CCMS?
    suppose a background job fails, can CCMS alert a user by email ?
    upto what level can CCMS be used to monitor systems? any ideas please share.
    Thanks
    Usman

    Sonali,
    You can do this through solution monitoring functionality of Solman.
    Solution Monitoring helps you to manage heterogeneous system landscapes efficiently.
    You can manage:
    ●      your systems and
    ●      your business processes
    in one tool.
    This uniform overview guarantees high performance and availability of all your business processes across various systems and system components. The SAP Solution Manager provides predefined views and values in the function sessions.
    The system monitoring guarantees the real time monitoring of all systems in a solution, based on the Computer Center Management System (CCMS).
    The CCMS provides a range of monitors for monitoring the SAP environments and its components. These monitors are indispensable for understanding and evaluating the behavior of the SAP processing environment. In the case of poor performance values, the monitors provide you with the information required to fine tune your SAP system and therefore to ensure that your SAP installation is running efficiently.
    The CCMS analysis monitors provide functions for
    ·        Checking the system status and the operating modes
    ·        Detecting and correcting potential problems as quickly as possible
    ·        An early diagnosis of potential problems, such as resource problems in a host or database system, which could affect the SAP system
    ·        The analysis and fine tuning of the SAP system and its environment (host and database system) to optimize the throughput of the SAP system
    Hope this helps. Please assign points and let me know if you need anything specific.
    Rgds
    Manish

  • How can you type without using capitals at the beginning of a sentence?

    How can you type something without using a capital letter at the beginning of a sentence. It always automatically outs a capital letter and I don't want one because it could be a case sensitive password?

    Tap the Shift key to turn off caps

Maybe you are looking for

  • Use of T code j1ianx19

    Hi Gurus 1) Could some one explain me how to extract the details using t code j1ianx19. What is the exact use of  t code J1ianx19. 2) What is Total Duty. Thanks & Regards naresh

  • I can't get my e-mail to work after installing Lion

    I installed Lion O.S. on my MacBook Pro and everythign works great except my e-mail, it just opens up an error screen??  Any help would be great!!

  • Configuration Manager Error

    Hi, I have got SQL 2005 Developer edition running and Websphere 6.1 installed, however when I run the LC configuration manager, at the steps where it tests the connection to websphere server, I get the following error: Failed to run JACL scripts. Doe

  • Assign Chief Position to custom OM Object Business Unit

    Hello Is it recommended or doable to assign chief position via 012 relationship to the top most custom object Business  Unit. Currently the  chief position relationships is for Org Units. We would like to keep Chief Position to OU, also if possible t

  • Creating a Login

    I'm having abit of trouble creating a login can someone rune this code and see if it works JAVA DAO package SportsUserwebsite; import java.io.*; import java.sql.*; import javax.naming.*; import javax.sql.*; import java.util.*; public class SporticusU