Change boolean indicator type across entire VI

I have a VI with hundreds of round boolean indicators.  I would like to change them to rectangular.  The only way I know to do this right now is to right click, then choose Replace and navigate to the rectangular type.  If I select several indicators at a time, this right-click context menu is no longer avaialble.
Is there a way to do this across the entire VI, either by editing a params file somewhere or by being able to select many at the same time/

bmishoe wrote:
thank you, I'll see what I can do...
Here's a Quick Drop plugin that'll do what you describe.  Change the style constant in the For loop to change what it replaces the selected objects with.
This VI is in LabVIEW 2012 and was not made pretty.
Jim
You're entirely bonkers. But I'll tell you a secret. All the best people are. ~ Alice
Attachments:
QD_ReplaceIndicator.vi ‏34 KB

Similar Messages

  • Digital Input VI boolean indicator

    I am using the Example VI Digital Input as part of Fieldpoint.
    It works fine on its own.
    That is, I can place a voltage across the terminals of the DI module and the respective Boolean LED lights up on the front panel.
    I'd like to use the VI as a subVI for another program.
    I wired the connectors of Digital Input.VI connector pane such that the Fieldpoint IO Input and Boolean indicator array have connectors.
    I placed the Digital Input.VI in the block diagram of another VI and created an indicator on that VI to see the status of the array within the Digital Input.VI.
    Running the higher level VI and the boolean array on it is disabled (greyed out) but the boolean array on the Digital Input.VI is working properly.
    Any ideas?
    I'm just looking for a way to obtain a status bit type response to be used elsewhere.
    If one of the DI module channels is set high then the bit would be set (LED on) in my higher level VI.

    Alright, found that if I just take out the guts (Fieldpoint IO, FP Read, Type, Boolean indicator) and use that in my VI all works well.
    Now all I need to do is determine what bits are set and act on set bits.

  • Change exchange rate type

    Hi,
    How can I change exchange rate type for posting principle flow in case of fixed term deposit. System by default takes M type. I want to change it to S type.Define  I have already changed exchange rate type in calculation indicator and Company Code Additional Data but it doesn't work.
    Thanks

    Hi,
    By default the exchange rate type M will only be picked.  The setting you make under calculation indicator is only for securities and loans area.
    For you requirement, pls check the note 450171 and see the appropriate place where you have to do the modification.
    Regards,
    Ravi

  • Saving large tiff files we see a lot of times the lines in the saved file that have either missing ( white) pixels or they appear as a black line across entire file or portion of it

    saving large tiff files we see a lot of times the lines in the saved file that have either missing ( white) pixels or they appear as a black line across entire file or portion of it

    Due to the current unavailability of clairvoyants and mind-readers in the forum, we respectfully request you supply sensible, complete details.
    BOILERPLATE TEXT:
    Note that this is boilerplate text.
    If you give complete and detailed information about your setup and the issue at hand,
    such as your platform (Mac or Win),
    exact versions of your OS, of Photoshop (not just "CS6", but something like CS6v.13.0.6) and of Bridge,
    your settings in Photoshop > Preference > Performance
    the type of file you were working on,
    machine specs, such as total installed RAM, scratch file HDs, total available HD space, video card specs, including total VRAM installed,
    what troubleshooting steps you have taken so far,
    what error message(s) you receive,
    if having issues opening raw files also the exact camera make and model that generated them,
    if you're having printing issues, indicate the exact make and model of your printer, paper size, image dimensions in pixels (so many pixels wide by so many pixels high). if going through a RIP, specify that too.
    A screen shot of your settings or of the image could be very helpful too,
    etc.,
    someone may be able to help you (not necessarily this poster, who is not a Windows user).
    Please read this FAQ for advice on how to ask your questions correctly for quicker and better answers:
    http://forums.adobe.com/thread/419981?tstart=0
    Thanks!

  • Odd even number and Boolean indicator

    Hi all,
    For example, I have these numbers from 0 to 112233. It will start counting from 0 and shown it on an output indicator. When it is even number (0,2 or 4,...) the Boolean indicator will become false, but when it is odd number (1,3 or,...) the Boolean indicator will become true.
    I'd like to ask if it is possible to detect the values changing in output indicator when it start counting numbers from 0, and then the Boolean indicator will become false or true depending on even or odd number shown on an output indicator? How can I do that?
    Thank you!

    johnsold wrote:
    It may not be that much faster. In the little test VI Q&R takes 581 ms for 10^8 iterations while AND takes 503 ms. That is 78 ps difference. Hardly enough time for a coffee break. Unless you drink really fast.
    Yes, both are "fast enough" for all practical purpose. Even thought they are nealy identical in speed, the Q&R shows more variability in execution time (10% variability), while the AND is singificantly more stable (>1% variability).
    (Make sure you disable debugging for a 10x speedup overall)
    It also seems that the AND code folds better. If we change the control to a diagram constant, the AND version speeds up by a factor of two, even though no folding is shown anywhere inside the sequence structure. I have no idea what that means.
    LabVIEW Champion . Do more with less code and in less time .

  • Custom table needs to be updated based on changes in Info type P0000

    Hi All,
       I have a requirement wherein when we make changes to info type P0000 this should be reflected to a custom table.
    If i create a new record, delete an existing record or make changes to a record in INFOTYPE P0000 this should also be reflected in my custom table.
       My custom table has 5 fields from info type p0000 and some custom fieds.
       please can you let me know exactly which user exit to use to acchieve the solution. and where exactly i can put the logic.
    Thanks,
    Mars

    Hi Venkat,
      I tried to code in the method AFTER_INPUT and executed but there are few thing which i have come across.
    1. when ever i create a new record in PA40 and each time i save the screens of PA40 this method is called and based on check it tries to update the table taht many times.
    2. The logic which i have used in the BADI implementations is as below:
      DATA: l_text TYPE string,
                 l_answer TYPE string,
                 lw_split TYPE XXXX.  (custom table)
      IF old_innnn NE new_innnn.
        lw_split-mandt = sy-mandt.
        lw_split-pernr = new_innnn-pernr.
        lw_split-begda = new_innnn-begda.
        lw_split-endda = new_innnn-endda.
        l_text = 'Does this employee need a split STIP?'.
            Display a pop up message to the user.
        CALL FUNCTION 'POPUP_TO_CONFIRM'
          EXPORTING
            titlebar                    = 'Choose'
            text_question               = l_text
            text_button_1               = 'Yes'
            text_button_2               = 'No'
            default_button              = '1'
            display_cancel_button       = space
         IMPORTING
            answer                      = l_answer
         EXCEPTIONS
            text_not_found              = 1
            OTHERS                      = 2.
        IF sy-subrc EQ 0.
          IF l_answer EQ '1'.
            lw_split-stflg = 'Yes'.
          ELSE.
            lw_split-stflg = 'No'.
          ENDIF.
        ENDIF.
        MODIFY TABLE  XXXX FROM lw_split.
        CALL FUNCTION 'BAPI_TRANSACTION_COMMIT'
          EXPORTING
            wait = 'X'.
      ENDIF.
    3. when i try to activate this chunk of code it gives me error  saying "XXXX" is unknown. i tried to declare it under TABLES but in Vain.
    4 I have also tried to use the modify statement in IN_UPDATE instead of updating custom table in same method but its giving me same error "XXXX" is unknown. i tried to declare it under TABLES but in Vain.
    can you let me know your view on this. The above chunk of code is in case of creating a new record in P0000 info type.
    Thanks,
    Mars
    Edited by: Mars878 on Oct 13, 2009 9:18 AM

  • Sharing an Indicator Value Across VI's

    Hi all LabView rookie so go easy on me,
    Basically I'm running a video in one VI using Windows Media Player and I extract the current position in the video using a Property Node which then writes this value to a double integer indicator. I want to share this indicator value across another VI whilst this video is running but I'm not sure how to do it. I'm pretty much using this to run the video:
    https://decibel.ni.com/content/docs/DOC-25131
    Thanks for any help.

    Dear cheemz,
    Thank you for posting this to the user forums.  I took a look at your code and can offer a couple of tips & tricks.
    At the end of the code you can expand the merge errors function to handle errors from multiple sources.  Note that the merge errors function does not concatenate errors; it returns the first error that it finds and if it finds no errors then it returns the first warning.
    You should also place boolean controls inside their respective event structure to restore their latch mechanical action behaviour.
    There may be a conflict from having the event structure timeout and the wait until next ms multiple function, so I would remove the wait until next ms multiple function from inside your while loop - it plays no role in the code.
    You code does look very good though - well done!
    As for the global variables issue - there is a chance that you can get race conditions with variables, so to try to mitigate this you should try to pass data around with global scope by using a functional global variable.  It stores the data in an uninitialised shift register; https://decibel.ni.com/content/docs/DOC-2143
    Since labVIEW is a dataflow language, a function only executes when all it's inputs have values and a function is only returned once all it's outputs have values.  The best way to force dataflow is to use the error cluster, so you could have an error in and error out as terminals in your subvi and make this the first thing that your main VI does (pass the error cluster).
    I hope this information helps and you are enjoying using LabVIEW.
    Kind Regards,
    Robert Ward
    Applications Engineer, NI

  • When I convert documents from pages to word, the format is changed partially and at times entirely. Any solution for this?

    When I convert documents from pages to word, the format is changed partially and at times entirely. Any solution for this?

    Gig Harbor Tina wrote:
    ...Is it possible that the server at work is somehow affecting these attachments?
    I can't say, but if that's the answer, trying to get it fixed might be impossible. Instead, I'd suggest compressing your attachments to create a .zip file. Decompression at the other end would take no time, and if the server changes the attachment's file type, just change it back to .zip.

  • System style boolean indicator

    Experts,
    Does anyone have a nice tidy way of displaying a boolean indicator in a system style? A checkbox does not seem like a good idea to me as it implies the user is able to click on it and change it. I could disable and grey it but again this implies something different.
    What I am after is a simple and neat method of displaying a boolean status to the user. I am using a small-ish boolean off the modern pallette at the moment, but it does not really fit in with the rest of the system scheme.
    Thanks
    Neil
    nrp
    CLA
    Solved!
    Go to Solution.

    Another option takes a bit of digging around in the control editor:
    1. Create a new custom control, starting with a system listbox. Once dropped, change to Customize Mode (click the wrench/spanner in the toolbar), right click on the border of the list box and choose to copy to clipboard.
    2. Create another new custom control, this time starting with a modern LED. Switch to the customize mode and right click on the border of the control and choose to paste from clipboard at the same size. 
    3. Repeat for false as well as true and resize parts to suit.
    4. I ended up with something like this:
    Attachments:
    System LED.ctl ‏4 KB

  • I can't put numbers on the decimals. It only allow ,00 as decimals. If i put 33.00 it's ok but i i put 33.44 when i press enter changes to 3344 as an entire number, i've try everything and can't find the solution. This should be a basic thing.

    I can't put numbers on the decimals. It only allow ,00 as decimals. If i put 33.00 it's ok but if i put 33.44 when i press enter changes to 3344 as an entire number, i've try everything and i can't find the solution. This should be a basic thing. How frustrating !!

    pedrofromsydney wrote:
    €          55,555.00
    that's the result i get. Still why can't i just type for ex. 29.55 and stay like that on the cell ? Why does it always change to 2955 or 2955.00. ??
    I don't understand this
    It appears you have the cell formatted to Currency, with the default two decimal places.
    What I don't understand, though is how Numbers arrived at a result of fifty five thousand five hundred fifty five on your entering the exact keystrokes in Yvan's post:
    an equals sign, followed by five ones, followed by a forward slash, followed by a 2.
    Here's the result I get:
    Could you do the following:
    Open a NEW Numbers document using the Blank template.
    Drag the Row and Column control (bottom right corner) to reduce the table to two columns and three rows.
    Enter the words "My table" in cell A1.
    Click on cell B2 to select it, then enter the formula 
    =11111/5
    Use only those eight keystrokes; do not include any commas, periods or other characters not shown.
    Click on B2 again to select it.
    Open the inspector and choose the Cell Format button.
    Do not make any changes in the Inspector window.
    Drag the Inspector window to the position shown in my screen shot.
    Take a screen shot that includes the Formula bar, the Table (with cell B2 selected) and the Cell Format Inspector pane (the same screen area as in my screen shot above).
    Post the screen shot in a reply to this post.
    I'm hoping there will be some clues as to what's happening here in the screen shot. Procedure for taking and posting a shot of part of the screen follows.
    Regards,
    Barry
    SCREEN SHOTS (Selected area)
    Place the mouse pointer at the top left corner of the area you want to include.
    Press shift-command-4.
    The mouse pointer will change to a plus sign on a circle.
    Hold down the mouse button and drag to the bottom right corner of the area you wan to capture.
    Release the mouse button.
    The screen shot will be saved to your desktop with the name "Picture 1" (The number will be different if you have taken other screen shots).
    POSTING
    In the Compose frame, place the Insertion point at the location you want the picture to be inserted.
    Click the camera icon above the compose frame to open the Insert Image dialogue.
    Click Choose file to open the Choose dialogue.
    If necessary, navigate to the Desktop and click on the 'by date column header to sort the files by date, most recent at the top.
    Select the most recent picture file.
    Click Choose.
    Wait for the picture's file name to appear beside Choose file.
    Click insert image.
    Done.
    B.

  • APO-DP - Change in Calculation Type of Key Figure in Production Environment

    Hi Team,
    I wish to know how to make a change in Calculation Type of Key Figure in Production Environment. I wish to change calculation type from "P" to "S" and also wish to enter Disaggregated Key Figure.
    Regards,
    Tarun Jha

    HI,
    The TR will not move the changes as you are expecting here.
    Any changes to planning area, below 5.0 need to de-intialize the planning area.
    just like
    1. hold the latest back up
    2. de-intialize planning area
    3. make the required changes to planning area
    4. initialize planning area and do conisistency checks
    5. load back the data to planning area at all CVC level
    all the steps need to perfom, in Dev and Quality and Production servers,
    Plan the activity for a weekend so that users will not get disturb*
    All the best
    ARUN R Y

  • My iCloud storage payment is going to be going through is 7 days but the card on file needs to be changed. How do I change he payment type?

    My iCloud storage payment is going to be going through is 7 days but the card on file needs to be changed. How do I change he payment type?

    Welcome to Apple Support Communities
    To change your payment, read > http://support.apple.com/kb/ht1918

  • How do i change the media type on a digital booklet when they option bar is greyed out?

    I downloaded an album a couple days ago which came with a digital booklet. I am trying to put it on my phone but need to change the media type to book to be able to do this. whenever I go to the get info tab, the options tab is completely greyed out and wont let me do anything to it. I have tried selecting read only on the file and it did not work. I have windows 8. If there's is any different way of getting this on my phone, anything would be great!

    The item must not be read only if you want to change it.
    In the new Get Info dialog the Media Kind is in a light grey. Next to that will be the word Music. Hover over it and you should see that it is part of a drop down list control, click and select Book.
    tt2

  • I tried to change the file type of the movie, but now I am unable to open/edit it in iMovie, HELP !

    I tried to change the file type of the movie, but now I am unable to open/edit it in iMovie, HELP !

    Thank you very much! This is exactly what I was looking for.
    I appreciate your time and effort in solving my question : )

  • Can we change the data type of a field based on the value of the field

    HI Gurus,
    My Requirement is as below -- Could you please guide me
    in the Printable Adobe form -- for ex - as usual for dates fields in the Object Pallette the object type is a date/time field  and for quantity/currency fields corresponding fields are taken
    now in case the either the date, quantity or currency is initial in place of displaying 0.00 or empty date we need to display N/A (Not Applicable)
    for this I would like to change the data type of the field
    to put it simply --
    we need to change the data type of date field from DATE&TIME to Char type to hold N/A or  Quantity field to Char field to hold N/A
    how can we realize this in SAP adobe forms
    Thanks in Advace
    Ramchander Rao.K

    Hello Ramchander,
         You cannot change the data type of the field at run time in Adobe forms because the type of field you choose at the time of design level is associated with the data type itself.
    If you want to achieve your requirement, then your main idea should be to set the data type as CHARACTER itself while designing the field in the adobe form itself. CHAR field will comfortably hold the value of Calculation/amount field, Currency field, Amount, Date, Time HHMMSS, Unit Accuracy, Currency key, Floating point number, Numeric text, Client, Language and many other data types.
    After designing the field as TEXT field in Adobe form you have two options.
    Option 1:
    Select the Date field initially as type TEXT field or CHAR field in Adobe forms.
    Suppose the name of the field is TEXTFIELD1, then write the Javascript code on this field in Initialize event as below.
    if ( this.rawvalue == null )
         this.rawvalue = "N/A";
    If the field is not blank, then it will show the date. Else it will show "N/A".
    Option 2:
    Select the Date field initially as type TEXT field or CHAR field in Adobe forms. Do the formatting part in ABAP itself. It will increase the performance. Avoid Javascript as much as possible.
    Suppose you have a DATE variable l_dats of type DATS. Then take another variable l_date of type CHAR. Then write the below ABAP code.
    MOVE l_dats TO l_date.
    IF l_date IS INITIAL.
         l_date = 'N/A'.
    ENDIF.
    Bind the l_date to the TEXT field in the form.
    Even in this case, if the field is not blank, then it will show the date. Else it will show "N/A".
    But I will suggest you to use Option 2 of keeping the AMOUNT, QUANTITY, DATE, TIME fields etc as CHAR or TEXT fields in Adobe form and do the required formatting in ABAP itself.

Maybe you are looking for

  • How to add custom error message in standard application log of change doc.

    Hi, While saving chnage document I need to add raise an error on specific condition. As Error messages is being shown in application log I added custom message in include LCRM_1O_UIF15 by using BAL_LOG_MSG_ADD FM however it is not showing in the scre

  • ITunes Won't Authorize for Automatic Downloads & Account Information Viewing

    Hi, So I've been having a problem signing into iTunes for the last few days now. First off, I've isolated the problem to my MacBook Pro and verified that Mac OS X/iTunes were both up to date. I've reinstalled iTunes and restarted. I've tried re-athor

  • CKPT : Terminating instance due to Error 472

    Hi All, I got the above error and the system stopped and restarted on the DR side. Snippet from Alert file before shutdown =========================== Wed Nov 27 22:39:12 2013 Thread 1 advanced to log sequence 10770   Current log# 2 seq# 10770 mem# 0

  • Windows 7 freezes / hangs when playing video or audio on any media player

    I've had this issue since installing Windows 7 (32 bit) over 2 months ago and have been actively seeking a fix for the majority of those two months. In windows XP pro (32 bit), I had no issues whatsoever. The problem manifests itself as a complete ha

  • Mbox 2 Mini for Yosemite?

    Hello, i have two computers running on yosemite, and my mbox2 mini works on one (an older computer) and not on the new laptop i got in fall 2014. the driver does install, and it appears in my system preference, but there is no firmware, and it states