Clarification on SendToVRU node

Hi All,
We have ICM  integrated with CVP using Type 10 network vru. 
I see there is one particular Label and correlation ID returned back to cvp when it encounters send to vru node for establishing VRU leg.
And there are many labels configured under this Routing client and do not see any default label for it.
I have gone through some documents and all mention just that a special label will be transferred to CVP.
I have also got to know from seniors that the very first label configured for this routing client will be returned.
I would like to have some clarification on which label will be returned and if it is sending very first label configured, is there any cisco document I can reference?
Thanks all in advance

there is nothing such very first label.
the net vru label is returned to routing client when script encounters send to VRU.
it is also sent out to routing clients when script has to run micro app or CVP application and it has not encountered a send to VRU node in Script execution.
ICM will decide what label to which routing client based on network VRU explored label configuration.
the label will be appended with corr id and send to the routing client.
if routing client is CVP:
now if your routing client is CVP, the label will map to VXML gateway and the VXML gateway will be configured with bootstrap application.
the bootstrap application will send htttp CALL request to call servers IVR service and the DNIS as the label.
now based on max DNIS length configured on CVP, CVP will figure out its a post routed call and split DNIS and corr id and present it ICM using request instruction.
ICM identifies the call and the node passes from success path.
and looking at the all of above , the call is also at VXML gateway port so ICM can now request CVP to send VXML docs to gateway for execution those are nothing but your micro apps or studio app.
if Routing client is CUCM:
if CUCM is the routing client, the ICM will send label back to CUCM with corr id appended.
CUCM has to pass label to CVP call server, CUCM does this using route pattern configured to match the pattern with label. corr id should also go to CVP.
once the label reaches CVP as DNIS, CVP does the same this as discussed above. it checks the length of DNIS and splits the corr id and DNIS and presents to ICM.
ICM identifies the call and sends one more label back to CVP to reach VXML gateway.
now the story follows as above discussed with CVP. 
Hope that clears out your doubt

Similar Messages

  • PCS calls are failing through "SendToVRU" node.

    Hi All
    we are using icm enabled PCS and getting problem that calls are failing through the send to VRU node.
    Actually we are getting Handoff.tcl errors on our monitoring system. From CVP error log we found that those errors are against PCS calls only and from ICM script we found the above.For reference i am attaching screenshot.
    Kindly help if anyone faced the same issue and got the solution.

    Not much info is provided, but are the calls which failing belong to a particular language? check below mentioned link and see if it applies for you.
    https://tools.cisco.com/bugsearch/bug/CSCtk13452/?referring_site=ss

  • Unable to play SWF media embedded in PDF

    Hello,
    Adobe Reader does not play SWF media embedded in PDFs, if SWF version is higher than 6. I get the error "The media clip cannot be played in rhe manner that the author intended. You may need to upgrade your player software or install new player software".
    I have installed Adobe Reader 9.3.0 and Acrobat Flash Player 10. Acrobat Flash Player plays all my SWF files without problem in Firefox browser .
    If I change version byte to 6 in the SWF media,  Reader happily plays it.
    Best regards,
    Angelina

    Does the ICM script make it through the SendtoVRU node successfully?  If so then on the gateway run
    debug http client error
    term mon
    This will show you any issues that are actually happening with playing media......
    Does the router call log on the AW show any error that you can paste?  Paste a screenshot of the ICM script maybe?
    Chad

  • CVP- call orginated CVP as media server

    In icm scripting, under  user.microapp.media_server vlaue  node I am using  the formula concaetnate("http://",call.RoutingClient,"7000/CVP/audio")
    to use the media server same as the call orginated call server.
    This works fine for all calls orginated from CVP. But calls orginated from cucm is not bring the right cvp server from
    call.RoutingClient. Instead it is always bringing CUCM routing client eventhough I used this node after sendtoVRU node.
    Anyone know how can I get the right call server for a cucm orginated call.

    As far as i can understand , you are using the CUCM Routing Client to send the Call to the Router , so you are usingas
    CTI Route Point registered with the Agent PG IP Address ...
    and as far as i know , in order to make it work like you want , i.e : change the routing client to CVP Route Client , you will need a Translation Route Node ....
    i would really be HAPPY to know any other method ...
    Thanks a lot ,
    Ahmed Salah

  • ICM Scripting. value on variable Call.RoutingClient

    Scenario:
    - UCCE 8.5 with CVP 8.5 - Type 10 NVRU
    -  Call initiated from a IP Phone dialing a CTI RP.
    -  CUCM is the routing client of the original call.
    -  UCCE script launch.
    -  Eventually the call hits a SendToVRU node.
    - At this time the NVRU label is sent back to CUCM. CUCM then sends the call to the CVP Call Server, and the routing client changes to be the CVP Call Server.
    - Afterward the call re-enters the UCCE script and I would expect variable Call.RoutingClient to contain the name of the CVP Call Server but still holds the name of the CUCM routing client.
    - Curiously the value of Call.RoutingClientId changes to the dbid (RCID) of the corresponding CVP Call Server routing client, which is normal because the RCID is used by the router to send the labels to the right routing client.
    Thus, I am curious why the disconnect between Call.RoutingClient and Call.RoutingClientID on CUCM originated calls after the routing client changes from CUCM to CVP Call Server.
    Which value should I expect on variable Call.RoutingClient? The original routing client, or the current routing client?

    The way I see it, the originating CUCM is a factor to determine which CVP Call Server will handle the call. After that, which VXML GW, VXML Server or media server decisions are made based on the location of the CVP Call Server and no so much the CUCM. To ensure that the closest VXML GW is use you need to use either different Network VRU labels for the CVP Call Server routing clients, or other mechanisms. CUCM will decide only which CVP Call Server the call connects in first place, and after that all decisions are off CUCM realm.
    Below is a more detailed description of what I am trying to accomplish.
    When the originating party dials the CUCM Route Point that triggers and associated ICM script. Eventually the script reaches the SendToVRU node and sends the label defined for the CUCM peripheral on the Network VRU. That  is a first transfer to a CVP Call Server and CUCM will handle it because at this time CUCM is still the routing client.
    When CUCM receives the label a decision is made either by CUCM route patterns with static routes (this is my case), SIP Proxy or H.323 GK, to which CVP Call Server to send the call.  If you have different CUCM clusters you can have different labels and make different decision (the Bangalore cluster send calls to CVP Call Servers in Bangalore, the London cluster uses CVP Call Server in London, and so on). If you have only one cluster serving agents all over the planet I don't think there is much room to fine control the CVP Call Server decision based on the actual location of the agent's phone that is what really matters.
    Anyway. when the call is connected to the CVP Call Server the routing client functions are passed to the CVP Call Server and CUCM is at that time totally out of the picture as far as routing decisions go.  
    The call re-enters the ICM Script now with a CVP Call Server being the routing client, and the CVP Call Server Routing Client Network VRU label is sent this time to the CVP Call Server looking for a VXML GW. That is a second transfers that is performed behind the scenes and is not expliticly seen on the ICM script.
    All the above works just fine.
    The challenge I am having is that I am using CVP Combos (VXML and CVP Call Server together) and I want to use the VXML Server that is co-resident with the CVP Call Server handling the call.  Obviously I don't have a SIP proxy or a CSS on the solution.
    To achieve that I have created ip host entries on the VXML GW to match the CVP Call Server routing client. For example if my CVP Call Server routing client name is CVP01 I have the following entries on the VXML GW
    ip host CPV01 10.0.0.1
    ip host CVP01-backup 10.0.0.2
    and on my ICM script I  want to use variable {Call.RoutingClient} to create the VXML Server url that goes in the microapp.media_server variable.
    That achieves two purposes,  first that I always use the co-resident VXML server to service the call, and second provides a basic redundancy through the CVP IVR -backup mechanism.
    It works just fine on the inbound calls because the value on Call.RoutingClient is correct, referring to the name of the routing client for the CVP Call Server handling the call.
    The problem is that for the CUCM originated calls, even if the routing client changed to be one of the CVP Call Servers, the value on the variable Call.RoutingClient still refers to the CUCM routing client name.
    Again, variable Call.RoutingClientID value is always correct. The issue is with the value on the Call.RoutingClient.
    I would assume that both should be consistent, and they are not at this time. There are workarounds but there are not as clean as I would like.
    The cleanest workaround I have come up with is to define ip host entries on the VXML GW to  match the CUCM routing client name, but I think that is confussing for  anyone reading the GW configuration that will wonder why the reference  to CUCM.
    So far at this time on the ICM script I have a bunch of IF Nodes to check the Call.RoutingClientID and then create the right VXML Server URI based on the the related name, but all is just to account for the fact that calls originated by CUCM have the wrong value on the Call.RoutingClient variable. All this I believe can be avoided if the values on the variables were consistent.
    I would like to hear some opinions from Cisco developers on this matter.

  • SAP Note #723909 Clarification needed: 2G heap for server nodes

    We mare upgrading from Enterprise 4.7 to ERP 6.0 SP12. For our ESS/MSS we will use standalone Java NW 7.0 SP14 with XSS SP12. Our portal servers and ERP ABAP are Unix Solaris 9 or 10 64-bit. The portal servers are 4CPU x 16G. We use three server nodes on our central instance and three server nodes on our dialog instance.  All server nodes have 2G heap.
    Recent load tests indicate we are reaching memory limits in the server nodes. THis causes frequent full GC with tenured objects deleted (very time consuming). We want to increase heap size > 2GB.  Note 723909 seems to say this can be done for 64-bit systems, but SAP appears to recommend additional server nodes with 2G heap. I think this is because of GC performance with large heap.
    - Are we supported with heap > 2G?
    - Are there still concerns with GC when heap > 2G?
    - Are there other reasons why heap should be no higher than 2G?
    Thanks in advance

    - Are we supported with heap > 2G?
    - Are there still concerns with GC when heap > 2G?
    - Are there other reasons why heap should be no higher than 2G?
    You´ve answered your questions yourself
    To have a fast J2EE engine you need to absolutely make sure all the heap is covered in physical memory. No swapping should take place at all. Once the system starts swapping in and out, you will loose a lot of performance.
    How big is your Oracle SGA? If you can decrase it so all the heaps (+ dispatcher heap) will fit in physical memory you can increase more. We use 2.5 - 3 GB heap (for BI) with three server nodes.
    Markus

  • How do I use the Index Values property node with a multidimensional array.

    I am using a 2D array to store operator inputs on my front panel.  I only want to display one element to the operator at a time.  I am trying to use the Index Values property node to change the displayed element.  However, I can only get the Rows index to work.  How do I direct the Columns index as well?  The help says to use one per dimension.  I need clarification on what this is talking about.  I've tried adding a second element to the property node, 2 seperate property nodes, and diferent wiring techniques. (series, parallel)

    If you only wire up one of the inputs (col or row) what you get out is a 1D array of either the column or row. If you wire controls to both, then you will get one element out of the array. Getting a single element in a 2D array requires you to specify both a row and column.
    Message Edited by Dennis Knutson on 02-08-2007 08:34 AM
    Attachments:
    Index 2D Array.PNG ‏2 KB

  • Root.sh failed at second node OUL 6.3 Oracle GRID 11.2.0.3

    Hi, im installing a two node cluster mounted on Oracle Linux 6.3 with Oracle DB 11.2.0.3, the installation went smooth up until the execution of the root.sh script on the second node.
    THe script return this final lines:
    CRS-4402: The CSS daemon was started in exclusive mode but found an active CSS daemon on node nodo1, number 1, and is terminating
    An active cluster was found during exclusive startup, restarting to join the cluster
    Start of resource "ora.crsd" failed
    CRS-2800: Cannot start resource 'ora.asm' as it is already in the INTERMEDIATE state on server 'nodo2'
    CRS-4000: Command Start failed, or completed with errors.
    Failed to start Oracle Grid Infrastructure stack
    Failed to start Cluster Ready Services at /u01/app/11.2.0/grid/crs/install/crsconfig_lib.pm line 1286.
    /u01/app/11.2.0/grid/perl/bin/perl -I/u01/app/11.2.0/grid/perl/lib -I/u01/app/11.2.0/grid/crs/install /u01/app/11.2.0/grid/crs/install/rootcrs.pl execution failed
    In $GRID_HOME/log/node2/alertnode.log It appears to be a Cluster Time Synchronization Service issue, (i didn't synchronyze the nodes..) however the CTSS is running in observer mode, wich i believe it shouldn't affect the installation process. After that i lost it...there's an entry CRS-5018 indicating that an unused HAIP route was removed... and then, out of the blue: CRS-5818:Aborted command 'start' for resource 'ora.asm'. Some clarification will be deeply apreciated.
    Here's the complete log:
    2013-04-01 13:39:35.358
    [client(12163)]CRS-2101:The OLR was formatted using version 3.
    2013-04-01 19:40:19.597
    [ohasd(12338)]CRS-2112:The OLR service started on node nodo2.
    2013-04-01 19:40:19.657
    [ohasd(12338)]CRS-1301:Oracle High Availability Service started on node nodo2.
    [client(12526)]CRS-10001:01-Apr-13 13:41 ACFS-9459: ADVM/ACFS is not supported on this OS version: '2.6.39-400.17.2.el6uek.i686'
    [client(12528)]CRS-10001:01-Apr-13 13:41 ACFS-9201: Not Supported
    [client(12603)]CRS-10001:01-Apr-13 13:41 ACFS-9459: ADVM/ACFS is not supported on this OS version: '2.6.39-400.17.2.el6uek.i686'
    2013-04-01 19:41:17.509
    [ohasd(12338)]CRS-2302:Cannot get GPnP profile. Error CLSGPNP_NO_DAEMON (GPNPD daemon is not running).
    2013-04-01 19:41:17.618
    [gpnpd(12695)]CRS-2328:GPNPD started on node nodo2.
    2013-04-01 19:41:21.363
    [cssd(12755)]CRS-1713:CSSD daemon is started in exclusive mode
    2013-04-01 19:41:23.194
    [ohasd(12338)]CRS-2767:Resource state recovery not attempted for 'ora.diskmon' as its target state is OFFLINE
    2013-04-01 19:41:56.144
    [cssd(12755)]CRS-1707:Lease acquisition for node nodo2 number 2 completed
    2013-04-01 19:41:57.545
    [cssd(12755)]CRS-1605:CSSD voting file is online: /dev/oracleasm/disks/ASM_DISK_1; details in /u01/app/11.2.0/grid/log/nodo2/cssd/ocssd.log.
    [cssd(12755)]CRS-1636:The CSS daemon was started in exclusive mode but found an active CSS daemon on node nodo1 and is terminating; details at (:CSSNM00006:) in /u01/app/11.2.0/grid/log/nodo2/cssd/ocssd.log
    2013-04-01 19:41:58.549
    [ohasd(12338)]CRS-2765:Resource 'ora.cssdmonitor' has failed on server 'nodo2'.
    2013-04-01 19:42:10.025
    [gpnpd(12695)]CRS-2329:GPNPD on node nodo2 shutdown.
    2013-04-01 19:42:11.407
    [mdnsd(12685)]CRS-5602:mDNS service stopping by request.
    2013-04-01 19:42:29.642
    [gpnpd(12947)]CRS-2328:GPNPD started on node nodo2.
    2013-04-01 19:42:33.241
    [cssd(13012)]CRS-1713:CSSD daemon is started in clustered mode
    2013-04-01 19:42:35.104
    [ohasd(12338)]CRS-2767:Resource state recovery not attempted for 'ora.diskmon' as its target state is OFFLINE
    2013-04-01 19:42:44.065
    [cssd(13012)]CRS-1707:Lease acquisition for node nodo2 number 2 completed
    2013-04-01 19:42:45.484
    [cssd(13012)]CRS-1605:CSSD voting file is online: /dev/oracleasm/disks/ASM_DISK_1; details in /u01/app/11.2.0/grid/log/nodo2/cssd/ocssd.log.
    2013-04-01 19:42:52.138
    [cssd(13012)]CRS-1601:CSSD Reconfiguration complete. Active nodes are nodo1 nodo2 .
    2013-04-01 19:42:55.081
    [ctssd(13076)]CRS-2403:The Cluster Time Synchronization Service on host nodo2 is in observer mode.
    2013-04-01 19:42:55.581
    [ctssd(13076)]CRS-2401:The Cluster Time Synchronization Service started on host nodo2.
    2013-04-01 19:42:55.581
    [ctssd(13076)]CRS-2407:The new Cluster Time Synchronization Service reference node is host nodo1.
    2013-04-01 19:43:08.875
    [ctssd(13076)]CRS-2412:The Cluster Time Synchronization Service detects that the local time is significantly different from the mean cluster time. Details in /u01/app/11.2.0/grid/log/nodo2/ctssd/octssd.log.
    2013-04-01 19:43:08.876
    [ctssd(13076)]CRS-2409:The clock on host nodo2 is not synchronous with the mean cluster time. No action has been taken as the Cluster Time Synchronization Service is running in observer mode.
    2013-04-01 19:43:13.565
    [u01/app/11.2.0/grid/bin/orarootagent.bin(13064)]CRS-5018:(:CLSN00037:) Removed unused HAIP route: 169.254.0.0 / 255.255.0.0 / 0.0.0.0 / eth0
    2013-04-01 19:53:09.800
    [u01/app/11.2.0/grid/bin/oraagent.bin(12922)]CRS-5818:Aborted command 'start' for resource 'ora.asm'. Details at (:CRSAGF00113:) {0:0:223} in /u01/app/11.2.0/grid/log/nodo2/agent/ohasd/oraagent_oracle/oraagent_oracle.log.
    2013-04-01 19:53:11.827
    [ohasd(12338)]CRS-2757:Command 'Start' timed out waiting for response from the resource 'ora.asm'. Details at (:CRSPE00111:) {0:0:223} in /u01/app/11.2.0/grid/log/nodo2/ohasd/ohasd.log.
    2013-04-01 19:53:12.779
    [u01/app/11.2.0/grid/bin/oraagent.bin(12922)]CRS-5019:All OCR locations are on ASM disk groups [DATA], and none of these disk groups are mounted. Details are at "(:CLSN00100:)" in "/u01/app/11.2.0/grid/log/nodo2/agent/ohasd/oraagent_oracle/oraagent_oracle.log".
    2013-04-01 19:53:13.892
    [u01/app/11.2.0/grid/bin/oraagent.bin(12922)]CRS-5019:All OCR locations are on ASM disk groups [DATA], and none of these disk groups are mounted. Details are at "(:CLSN00100:)" in "/u01/app/11.2.0/grid/log/nodo2/agent/ohasd/oraagent_oracle/oraagent_oracle.log".
    2013-04-01 19:53:43.877
    [u01/app/11.2.0/grid/bin/oraagent.bin(12922)]CRS-5019:All OCR locations are on ASM disk groups [DATA], and none of these disk groups are mounted. Details are at "(:CLSN00100:)" in "/u01/app/11.2.0/grid/log/nodo2/agent/ohasd/oraagent_oracle/oraagent_oracle.log".
    2013-04-01 19:54:13.891
    [u01/app/11.2.0/grid/bin/oraagent.bin(12922)]CRS-5019:All OCR locations are on ASM disk groups [DATA], and none of these disk groups are mounted. Details are at "(:CLSN00100:)" in "/u01/app/11.2.0/grid/log/nodo2/agent/ohasd/oraagent_oracle/oraagent_oracle.log".
    2013-04-01 19:54:43.906
    [u01/app/11.2.0/grid/bin/oraagent.bin(12922)]CRS-5019:All OCR locations are on ASM disk groups [DATA], and none of these disk groups are mounted. Details are at "(:CLSN00100:)" in "/u01/app/11.2.0/grid/log/nodo2/agent/ohasd/oraagent_oracle/oraagent_oracle.log".
    2013-04-01 19:55:13.914
    [u01/app/11.2.0/grid/bin/oraagent.bin(12922)]CRS-5019:All OCR locations are on ASM disk groups [DATA], and none of these disk groups are mounted. Details are at "(:CLSN00100:)" in "/u01/app/11.2.0/grid/log/nodo2/agent/ohasd/oraagent_oracle/oraagent_oracle.log".
    2013-04-01 19:55:43.918
    [u01/app/11.2.0/grid/bin/oraagent.bin(12922)]CRS-5019:All OCR locations are on ASM disk groups [DATA], and none of these disk groups are mounted. Details are at "(:CLSN00100:)" in "/u01/app/11.2.0/grid/log/nodo2/agent/ohasd/oraagent_oracle/oraagent_oracle.log".
    2013-04-01 19:56:13.922
    [u01/app/11.2.0/grid/bin/oraagent.bin(12922)]CRS-5019:All OCR locations are on ASM disk groups [DATA], and none of these disk groups are mounted. Details are at "(:CLSN00100:)" in "/u01/app/11.2.0/grid/log/nodo2/agent/ohasd/oraagent_oracle/oraagent_oracle.log".
    2013-04-01 19:56:53.209
    [crsd(13741)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 20:07:01.128
    [crsd(13741)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 20:07:01.278
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 20:07:08.689
    [crsd(15248)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 20:13:10.138
    [ctssd(13076)]CRS-2412:The Cluster Time Synchronization Service detects that the local time is significantly different from the mean cluster time. Details in /u01/app/11.2.0/grid/log/nodo2/ctssd/octssd.log.
    2013-04-01 20:17:13.024
    [crsd(15248)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 20:17:13.171
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 20:17:20.826
    [crsd(16746)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 20:27:25.020
    [crsd(16746)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 20:27:25.176
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 20:27:31.591
    [crsd(18266)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 20:37:35.668
    [crsd(18266)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 20:37:35.808
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 20:37:43.209
    [crsd(19762)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 20:43:11.160
    [ctssd(13076)]CRS-2412:The Cluster Time Synchronization Service detects that the local time is significantly different from the mean cluster time. Details in /u01/app/11.2.0/grid/log/nodo2/ctssd/octssd.log.
    2013-04-01 20:47:47.487
    [crsd(19762)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 20:47:47.637
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 20:47:55.086
    [crsd(21242)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 20:57:59.343
    [crsd(21242)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 20:57:59.492
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 20:58:06.996
    [crsd(22744)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 21:08:11.046
    [crsd(22744)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 21:08:11.192
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 21:08:18.726
    [crsd(24260)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 21:13:12.000
    [ctssd(13076)]CRS-2412:The Cluster Time Synchronization Service detects that the local time is significantly different from the mean cluster time. Details in /u01/app/11.2.0/grid/log/nodo2/ctssd/octssd.log.
    2013-04-01 21:18:22.262
    [crsd(24260)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 21:18:22.411
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 21:18:29.927
    [crsd(25759)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 21:28:34.467
    [crsd(25759)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 21:28:34.616
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 21:28:41.990
    [crsd(27291)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 21:38:45.012
    [crsd(27291)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 21:38:45.160
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 21:38:52.790
    [crsd(28784)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 21:43:12.378
    [ctssd(13076)]CRS-2412:The Cluster Time Synchronization Service detects that the local time is significantly different from the mean cluster time. Details in /u01/app/11.2.0/grid/log/nodo2/ctssd/octssd.log.
    2013-04-01 21:48:56.285
    [crsd(28784)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 21:48:56.435
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 21:49:04.421
    [crsd(30272)]CRS-1012:The OCR service started on node nodo2.
    2013-04-01 21:59:08.183
    [crsd(30272)]CRS-0810:Cluster Ready Service aborted due to failure to communicate with Event Management Service with error [1]. Details at (:CRSD00120:) in /u01/app/11.2.0/grid/log/nodo2/crsd/crsd.log.
    2013-04-01 21:59:08.318
    [ohasd(12338)]CRS-2765:Resource 'ora.crsd' has failed on server 'nodo2'.
    2013-04-01 21:59:15.860
    [crsd(31772)]CRS-1012:The OCR service started on node nodo2.

    Hi santysharma, thanks for the reply, i have two ethernet interfaces: eth0 (public network 192.168.1.0) and eth1 (private network 10.5.3.0), there is no device using that ip range, here's the output of route command:
    (Sorry for the alignment, i tried to tab it but the editor trims it again)
    Kernel IP routing table
    Destination Gateway Genmask Flags Metric Ref Use Iface
    default 192.168.1.1 0.0.0.0 UG 0 0 0 eth0
    private * 255.255.255.0 U 0 0 0 eth1
    link-local * 255.255.0.0 U 1002 0 0 eth0
    link-local * 255.255.0.0 U 1003 0 0 eth1
    public * 255.255.255.0 U 0 0 0 eth0
    And the /etc/hosts file
    127.0.0.1 localhost localhost.localdomain localhost4 localhost4.localdomain4
    ::1 localhost localhost.localdomain localhost6 localhost6.localdomain6
    10.5.3.1 nodo1.cluster nodo1
    10.5.3.2 nodo2.cluster nodo2
    192.168.1.13 cluster-scan
    192.168.1.14 nodo1-vip
    192.168.1.15 nodo2-vip
    And the ifconfig -a
    eth0 Link encap:Ethernet HWaddr C8:3A:35:D9:C6:2B
    inet addr:192.168.1.12 Bcast:192.168.1.255 Mask:255.255.255.0
    inet6 addr: fe80::ca3a:35ff:fed9:c62b/64 Scope:Link
    UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
    RX packets:34708 errors:0 dropped:18 overruns:0 frame:0
    TX packets:24693 errors:0 dropped:0 overruns:0 carrier:0
    collisions:0 txqueuelen:1000
    RX bytes:48545969 (46.2 MiB) TX bytes:1994381 (1.9 MiB)
    eth1 Link encap:Ethernet HWaddr 00:0D:87:D0:A3:8E
    inet addr:10.5.3.2 Bcast:10.5.3.255 Mask:255.255.255.0
    inet6 addr: fe80::20d:87ff:fed0:a38e/64 Scope:Link
    UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
    RX packets:0 errors:0 dropped:0 overruns:0 frame:0
    TX packets:44 errors:0 dropped:0 overruns:0 carrier:0
    collisions:0 txqueuelen:1000
    RX bytes:0 (0.0 b) TX bytes:5344 (5.2 KiB)
    Interrupt:23 Base address:0x6000
    lo Link encap:Local Loopback
    inet addr:127.0.0.1 Mask:255.0.0.0
    inet6 addr: ::1/128 Scope:Host
    UP LOOPBACK RUNNING MTU:16436 Metric:1
    RX packets:20 errors:0 dropped:0 overruns:0 frame:0
    TX packets:20 errors:0 dropped:0 overruns:0 carrier:0
    collisions:0 txqueuelen:0
    RX bytes:1320 (1.2 KiB) TX bytes:1320 (1.2 KiB)
    Now that i'm thinking i've read somewhere that ipv6 was no supported...yet there's no relation with the 169.254.x.x ip range.

  • Difference among Model node creation, model attribute creation and the field creation in database through AET?

    Hello Friends,
    To display the field on the View, we can create the field via 3 ways:
    1) By creating the model attribute
    2) By creating the model node using the GENIL object and using its attributes in view
    3) Creating the field in Database structure using AET
    But, i am not aware that in exactly what kind of business scenarios we use the above 3 methods to create the field.
    Could you help me out to clarify the same.

    Hi Dev,
    1). By creating the model attribute: we will use this option in case of the field is avaibla in stanadrd sap system. It might be in another under child context nodes and we will use BOL relations to access the attribute.
    2).  By creating the model node using the GENIL object and using its attributes in view: We will use this option incase of there is no standard provision to use. Means you want to create any custom assignment block with custom attributes then you can go for this option. More over we can use AET to create custom genil object. We have an option Create Table in AET.
    3).Creating the field in Database structure using AET: We will use this option incase of there is no attribute in database relevant to your requirement then we will go for AET enhancement.
    Hope this might give you little clarification..
    Best Regards,
    Dharmakasi.

  • Context Mapping: child-nodes of non-mapped parent nodes

    I am somewhat curious about Context Mapping in WebDynpro.
    Which parents nodes need to be mapped in order to map child nodes ? Does a child node has more than one parent node (e.g. grandparent - two steps above) ?
    A.1  -
    MAPPED----
    >    B.1
      - A1.1   NOT MAPPED
      - A1.2   NOT MAPPED
            - A.1.2.1     MAPPED TO>    B.1.2.4
            - A.1.2.2   NOT MAPPED
      - A1.3   NOT MAPPED
    Is it sufficient that only one of these parent nodes (e.g. direct parent node not mapped, but parent node of this parent node is mapped) need to be mapped so that the child node can be mapped ?
    Is this assumption true or not ?
    The SAP library states:
    "Conversely, child nodes of non-mapped parent nodes cannot be mapped, otherwise this would result in irresolvable conflicts at runtime with respect to the parent-child relation in the context and the mapping relation." (http://help.sap.com/saphelp_nw04/helpdata/de/51/a3384162316532e10000000a1550b0/content.htm)
    This statement is not absolutely clear on this issue.

    Let me put it this way
    You have a node vehicle and you have a child node for that the car. The car node have parameters car1, car2.
    Let the vehicle node have parameters veh1 and veh2
    Then if you map vehicle node one to any other node (say in the comp. controller) you have the option of mapping its children i.e veh1,veh2 and carnode.
    You can have that veh1 is mapped and veh2 is not mapped.
    vehicle node(mapped)
    veh1(may or may not be mapped)
    veh2(may or may not be mapped)
    car node(may or may not be mapped)
    If instead you try to map only the car node the vehicle node will also get mapped automatically but not it's child parameters like veh1 and veh2.
    vehicle node(mapped)
    veh1(may or may not be mapped)
    veh2(may or may not be mapped)
    car nodemapped)
    car1(may or may not be mapped)
    car2(may or may not be mapped)
    Hope this would help.
    Do revert for further clarification
    Regards
    Noufal

  • Child element of target node in message mapping getting suppressed

    Hello All,
                      I am having  mapping where i am trying  to generate the target node based on some condition of the source structure ,this is working fine ,I am able to generate the target node once the condition gets satisfied ,but the problem is one of the  child elements of the same node is not getting populated,its getting suppressed,i have some condition for the same
    I checked  the  queues its showing value as
    SUPPRESS
    Value
    Value ( in grey )
    But still element is not getting generated..
    I have added a condition used at the node function and apart from other condition of element..
    If some body have the solution for the same,please help me out
    Thanks in advance
    Rajesh

    Hi Rajesh,
    The Error is mostly cause of that the node and your child are in same context.
    You got to remember that the parent node creates the context, and then the child element puts the value in it.
    Try putting your child element to a higher context then mapwithdefault for your supress and then removecontext.
    This Issue, you got to work it out with the node functions,
    I had the same kind of issue in my mapping, it was rectified with the help of node functions as mapwithdefault, removecontext.
    Further unless one sees the mapping of your issue it is a bit difficult to imagine it and answer it.
    For more clarifications please give the full hierarchy, and the condition. As of now try with the node functions.
    Thanks
    Ashmi

  • Thru code how to create a context node n context attribute for a table

    Hi Friends....i need some clarification...according to my requirement i need 2 create contx node n ctx attribute for a table..i.e through the code(implemention NWDS) means this has 2 b done in dynamically...
          More clearly according to the structure of a table in MySql DB the same table structure  has 2 b designe in my view ..suppose my table(MySql) have 20 col's(name,dept,desig..) n 300 recoreds ..i hav to show that structure in view.
    waiting for reply..frndzzzzzzzz

    Hi Rajeshkelam,
    Take a Value Node say "Employee".
    Create 20 Value attributes (name, dept, desig..) under the Value Node(Employee).
    Then Create a Dynamic Table using the "Employee" Value Node.
    check this threads.
    Dynamic table creation
    Dynamic Table
    Regards,
    Mithu

  • Search with "Current Node + All Subfolders" not functioning correctly

    Hi,
    We are having an issue with the search function of SCCM 2012 Admin Console. We have built multi-level folder structure to SCCM which matches our organizational unit structure in AD.
    The issue occurs when trying to search with "Current Node + All Subfolders" option in a folder to get listing of all collections nested in the structure. As a result we get incomplete list of collections and majority of them are not showing
    up. Sometimes the console even crashes when trying to do this kind of search. Note that this behaviour only occurs when searching inside a folder, not in the device collections root node.
    We managed to trace the SQL query in the above situation from SMSProv.log, and it is as follows:
    select  all SMS_Collection.SiteID,SMS_Collection.CollectionType,SMS_Collection.CollectionVariablesCount,SMS_Collection.CollectionComment,SMS_Collection.CurrentStatus,SMS_Collection.HasProvisionedMember,SMS_Collection.IncludeExcludeCollectionsCount,SMS_Collection.IsBuiltIn,SMS_Collection.IsReferenceCollection,SMS_Collection.LastChangeTime,SMS_Collection.LastMemberChangeTime,SMS_Collection.LastRefreshTime,SMS_Collection.LimitToCollectionID,SMS_Collection.LimitToCollectionName,SMS_Collection.LocalMemberCount,SMS_Collection.ResultClassName,SMS_Collection.MemberCount,SMS_Collection.MonitoringFlags,SMS_Collection.CollectionName,SMS_Collection.PowerConfigsCount,SMS_Collection.RefreshType,SMS_Collection.ServiceWindowsCount from vCollections AS SMS_Collection  where (SMS_Collection.SiteID
    in (select  all Folder##Alias##810314.InstanceKey from vFolderMembers AS Folder##Alias##810314 
    where (Folder##Alias##810314.ObjectTypeName = N'SMS_Collection_Device'
    AND Folder##Alias##810314.ContainerNodeID in
    (16777237,16777374,16777384,16777385,16777375,16777376,16777377,16777378)))
    AND SMS_Collection.CollectionType = 2) order by SMS_Collection.CollectionName
    From this we noticed that not all ContainerNodeIDs are searched, but a list of only 8 ContainerNodeIDs. These ContainerNodeIDs remain the same if the search is done again in the same folder. The same behaviour repeats also in other folders with a different
    list of ContainerNodeIDs.
    For clarification I'll attach a picture which shows our folder structure with ContainerNodeIDs and ParentContainerIDs. We have also marked the containers which were present in SQL statement. From this you can clearly see there should have been far more ContainerNodeIDs
    than listed in the SQL query. Is this a bug in the admin console or could this be a problem with our site database? Is anyone else experiencing similar issues? We have written a custom
    powershell script that reads containers from SMS_ObjectContainerNode WMI-class recursively and is able to return complete list of folders and their subfolders, so we assume that our site database and WMI on site server is functioning correctly.
    We noticed this on CU2 (could have been present also earlier) and updating to CU3 did not fix the problem. Currently we are running SCCM 2012 SP1 CU3 with one primary site. All components besides distribution point is running on the site server. Distrubution
    point is running on a separate server. Our SQL server is running on the site server.
    Best Regards,
    Juha-Matti

    Sorry for the very long delay. I created the ticket in the autumn of last year and just received the final verdict to this issue.
    Microsoft support said they were able to reproduce the problem and that they contacted the product group about this issue. It turns out that this behaviour is by design (wait, what?) and since it is by design there is nothing they
    can/will do about it.
    So the only choice is to request a tailored customization for SCCM2012, which probably in this case (as it is by design) would cost.
    I feel a bit puzzled: how can it be by design if it clearly does not work?

  • Oracle 11gR2 RAC setup with ASM option running on two nodes . Seeking help

    Hi ,
    Recently we have migrated to 11gR2 extended RAC for one of our application using ASM . Its a two node RAC setup . We are using ASM Normal redundancy feature maintaining two failure group .
    I need few clarification regarding our new DR set up .
    We are planning to have EMC SRDF replication from any of node storage ( Either 1 or 2) to the DR disks .
    Its stright to use when we use the normal file systems . In case of ASM , I am not sure how this replication will work ? and on which level the replication should happen ?
    Do i need an ASM instance up and running on DR server , Which will recognize the disks as it is once DR disks are separated from prod replication and assigned to the server ?
    What should be prerequisite on DR server before we can start the srdf replication (EMC) and make it work .
    Thanks for All your Valuble suggestion .

    Before you decide to use EMC replication give considerable thought to the fact that you are introducing a single point of failure.
    Hardware snapshot replication is very fast. That is all it is. If you database crashes because of corruption on disk ... your replica will be equally corrupt.
    What is fast can not do what DataGuard does ... verify quality. If the point is DR. Go with DataGuard unless EMC is willing to, in writing (not verbally) give you a guarantee (in hard cash) to cover all costs if they replicate bad blocks and it causes an outage.
    And just so no one thinks I'm picking o EMC ... the same weakness exists with all of the other storage vendor's products.

  • Threading and Re-Use of buffers Using Call By Reference node (Duct Tape required)

    I have been trying to get the following information into the public domain for years and now that I have the answers, I will share with those that may be interested.
    Warning!
    Wrap your head in duct tape before reading just for safety sakes.
    My two questions have been;
    1) can LV Re-use the buffers of the calling VI when using VI Serve Call by reference?
    2) Is the UI thread used when using Call by reference?
    1. When calling a VI using the call by reference node, does the data going into the connector pane of the node get copied, or is it in-line as it would be with a properly set up subVI?
    Short answer: It is somewhere in-between.
    Long answer:
    The compiler doesn't know what VI will be called, but it does have a hint:
    the reference wired into the Call By Reference node. It uses that to get the "Prototype" for the call. So for the best performance, use a prototype that has the same "in-placeness characteristics" as the called VI. That being said, users don't know what the "in-placeness characteristics" are.
    Before I go into the details, I should say that the overhead of these copies shouldn't matter much unless it is a large data structure (an array with a lot of elements, or a cluster/class with many fields or containing large arrays etc.).
    Example 1:
    If the prototype does not modify the data then the compiler assumes that the Call By Reference node will not modify the data. However at run-time a check is made to see if the actual called VI will modify the data. If so, then a copy is made and passed in so that the original data can remain unmodified.
    Example 2:
    If the prototype contains an input that is wired through to an output in such a way that both the input and output terminals can use the same memory buffer, but at run-time a check determines that the actual called VI's input and output do not share a buffer, then a copy will be made from the actual call's output to the original VIs (combined input and output) buffer.
    I should also mention that even with this "attempt to agree with the prototype" behavior, it's not always possible to get as good performance as a regular SubVI call. For instance if you have a situation where the prototype does not modify the data and passes it through to an output then the compiler must assume that the data is modified (because as in example 2, there exist VIs that may modify it even if the actual VI called does not).
    And there are some caveats:
    1) This "using a prototype" behavior was new to 2009. Before that we used a more naive way of passing data that assumed all inputs will be modified and no outputs share a buffer with an input.
    2) This behavior is subject to change in future versions, if we find further optimizations.
    3) This behavior is the same as we use for dynamic dispatch VIs (when using LV classes)
    4) If you want to create a VI only to be used as a prototype, then you can use features of the In-Place Element Structure to control the "in-placeness characteristics" Namely the In/Out Element border nodes, the "Mark as modifier" feature of the border nodes (note the pencil icon on the In Element), and the Always Copy node.
    5) The prototype is only the first reference ever wired into the Call By Reference node. So if you do make a new prototype VI, you can't just make a reference out of it to wire to the Call By Reference node. I suggest deleting the Call By Reference node and dropping a new one.
    6) For remote calls, we always have to "make copies" by passing data over a network.
    I hope this helps, if you want any further information/clarification, then feel free to ask.
    2. Does the call by reference node execute in the UI thread? If the call is being made by a remote machine over ethernet, which thread does the host (the machine that makes the call by reference) execute on and which thread does the target (the machine that contains the VI file) execute on?
    In the local case, the Call by Reference node does not require the UI thread and can run in whatever thread the VI wants to execute in.
    When calling a remote VI, the Call by Reference node uses the UI thread (detailed below) on both the client and on the server.
    The client uses the UI thread to send the call request to the server and then again when the response comes back. The UI thread is not blocked during the time in between.
    The server receives the TCP message in the UI thread and then starts the call in the UI thread. The server also uses the UI thread to send the response back to the client. The UI thread is not blocked on the server during the execution of the VI.
    I hope people find this when they need it!
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction
    Solved!
    Go to Solution.

    I never use duct tape. I wrap my head in aluminum foil and thus get much better shielding from the aliens trying to tap my mind.
    Also easier to remove later, but why risk taking it off??
    LabVIEW Champion . Do more with less code and in less time .

Maybe you are looking for

  • Syncing with windows media player

    Do I have to have my music in itunes or can I sync with the music I have in my windows media player?

  • Issue with scene order in flash

    Hi, The order in which my scenes are arranged in the scene panel is causing my buttons to link to the incorrect scene instead of the scene listed in the code on the button. I have several(47) scenes setup with buttons linking to different scenes(see

  • How many templates are in iWeb?

    Greetings folks, I am considering setting up a website for a business I have and am wondering if there is a good selection of templates to choose from and how many? I have used Homepage to share photos before and feel that the selection of frames for

  • How did I get scratches on my iPhone 6

    i just purchased my first iPhone a couple of months ago and I already have a scratch on the touch screen

  • Regarding Attachments in Collaboration tasks

    hi, I have created tasks and have attachments along with the same. But when i open any type file other than text i get an error. Can anybody give any pointers on this? Also, Can i add attachments while creation of tasks or do i have to edit tasks and