Compatibility of daqmx driver versions

Hallo,
I am developing a c# project for the NI USB-6008 (however without using the measurement studio).
In order to be able to use the software, the costumer will have to install the daqmx driver. It seems that the best way to do this (considering the size of the installed files) is by installing the daqmx runtime enginge. As far as I know the version of this runtime engine has to be equal to the version of the daqmx driver used during development (is this correct?). However when installing the runtime enginge (or generally the daqmx driver) there is also installed an update service. Thus my question is:
1) Does the update service also change the version of the daqmx driver? Or does it "just" install critical updates of it which keep the version unchanged resp. such that it is still compatible with that version?
In other words: how can I be sure that the version of the daqmx driver of the user will be compatible to the version of my development system (with which the whole software was tested)?
2) For my c# project I have to add the two reference NationalInstruments.Common and NationalInstruments.DAQmx. When adding these references the respective version of them is shown. I assume that the neccessary version for the daqmx runtime engine has to be the same like the one shown for NationalInstruments.DAQmx. Is this correct? And what about the version of the NationalInstruments.Common library. How can I be sure that it is compatible to the one of the user?
Thank you for your reply,
Sebastian

Hi SebBr,
To address your first question, the version of the NI-DAQmx run-time engine installed on your customers' computers must be equal to or greater than the version with which you developed your software. The run-time engine is backwards compatible.
To address your second question, when distributing NI-DAQmx .NET applications, you have to distribute both the run-time engine and the version of the .NET libraries you used while building your application. You can distribute these .NET assemblies conveniently by using the MStudioDAQmx merge modules that install with .NET development support for DAQmx.
To reiterate, for the customer machine:
-NI-DAQmx run-time needs to be of equal or later version than the one you used during development
-The NI-DAQmx .NET assemblies need to match the versions you used while building (compiling) your .NET application.
Let me know if you have any questions!
Daniel D.
National Instruments
Automated Test Software R&D

Similar Messages

  • MyDAQ is not recognized under Window7 (32b) - "upgrade" to older driver version??

    Hi,
    although my myDAQ appears in the Windows device manager without exclamation marks and the blue LED lights up, the myDAQ does not appear in MAX and I am not able to use it.
    Starting up NI myDAQ Troubleshooting Utility yields the following strange error message:
    Device Drivers Installed (Failed)
    - Using DAQmx Driver Version 9.3.5f2 . Please upgrade to version 9.1.1 or higher before using the myDAQ device. (Critical Failure)
    - Using ELVISmx Driver Version 4.3.89.0. Driver version exceeds requirement.
    Any idea what's going on there?
    Best regards,
    Christian

    Hi Christian,
    I would recommend you to UPgrade to the latest driver version 9.5.
    That should hopefully solve the problem.
    Cheers, RMathews

  • Mydaq required daqmx driver

    Hello,
    I have problem with my system to make it recognize the NI mydaq device.
    I have the newest DAQmx driver, version 9.7.0.
    When I run the Trubleshooting utility, I get this error msg:
    Using DAQmx Driver Version 9.7.0 . Please upgrade to version 9.1.1 or higher before using the myDAQ device. (Critical Failure)"
    This look stupid, why the NI MyDAQ cannot cooperate with the newest DAQmx driver?? Do I have to upgrade my DAQmx driver to 9.1.1. ??? But I need the newest driver for my LabView projects, so this looks to be a dead-end...?
    Any advice how to solve this problem?
    Thanks!

    Strange enough, but the NI MyDAQ started to work. I can use the features of the ELVIS Instrument Launcher too (scope, DMM, etc.).
    What is more strange, the Troubleshoting utility is still telling me that non-sense error message about problematic DAQmx driver version...

  • Compatability Issues With Latest Version of DAQmx

    This one has got me stumped, so I thought I would go to the message boards.
    I am running some equipment that returns a voltage thru a NI USB-6361. The company that has hired me was using an older version of LabView (I cannot tell you which one, 2012 I think). Further, they are using DAQmx 9.5.5, which came with the USB-6361. My problem is getting my computer to A)recongnize the USB and B)still keep all my DAQmx VI Icons when I am programming. If I roll back the DAQmx software ti 9.5.5, I lose my Icons, but if I stay with DAQmx 9.9 I can see the USB in MAX, but that is it. In MAX I cannot create a task or anything. It shows it as "Not present"  I am using LabView 2013, and I have done everything I can think of. Has anyone had this problem? How do I fix it. I thought DAQmx 9.9 was supposed to be compatable with this device. Thanks in advance for the help.
    Solved!
    Go to Solution.

    Have a look at this:
    Compatibility LabVIEW & DAQmx
    If you are using LabVIEW 2013 then you need to have at least DAQmx 9.7.5.
    Regards, Jens
    EDIT: And yes, DAQmx 9.9 should be compatible with your USB 6361

  • What version of the DAQmx driver is compatible with DAQmx 8.5.11.22

    Hi;
    I have a a new software in charge.
    It's including NAtionalInstruments.DAQmx V8.5.11.22 and NationalInstruments.Commun V8.1.11.168.
    Does somebody know what is the driver version, that I need to install before deploying ?
    Regards
    Join: the error shown at runtime
    Attachments:
    ErrorAtRuntime.jpg ‏15 KB

    DAQmx is a driver.  So I'm really confused at your question.
    What software are you using?  Based on the version numbers, it look a lot like you ae using TestStand, but I can't say for certain.  Is there more to the error window?  You seem to have cut part of it off.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • I use labview 8.0 and i can not run daqmx driver for pcmcia 6062e daq card

    i use labview 8.0 on window xp .when i installed a PCMCIA daq card 6062E, i could not run daqmx driver.It is fine to see that the traditional version is working well.When i install daq card sometimes it is working well with traditional driver  but mostly i see error on reading an analog input from PCMCIA daq device.An error called 'base adress' occures .I use last version of driver that is daqmx 8.0.1. and i have installed this correctly but again i could not  see any signal on the test panel for daq-mx driver.I don't know what is the problem.Also when i install PCMCIA daq card Please reply this message.I need your helps.
    Thanks

    Hello,
    Thanks for your reply.I will try to answer your questions.
    I have checked the Device Mananger and I have seen that the device is detected by Windows  XP.  For another question the card shows up under both NI-DAQmx Devices and Traditional NI-DAQ (Legacy) Devices consistently in the Measurement & Automation Explorer.I use a way that I reset the driver for traditional NI-DAQ in MAX,and then i reset the device for NI-DAQmx driver in MAX and again i tried to run the test panel of DAQmx driver but again i saw a wrong signal or noise signal on the test panel i could not see the sinusoidal signal that i connected. i do get the test panels to run with the card using the DAQmx driver,  But could not run the DAQ diagnostic utility.The error was as i specified below.
    03.05.2006 09:49:35
    Results saved to:  C:\Documents and Settings\serkan\Desktop\Diagnostic Results.txt
    Selected Device: Dev1
    Device Type: DAQCard-6062E
    Serial Number: 107509E
    Device Support: (PASS)
    NI-DAQmx Version: 8.0 (PASS)
    Device Reset: (FAIL)
    Error -50002 occurred at an unidentified location
    Possible reason(s):
    The specified device is not a valid device. The operation could not be completed as specified.
     ------ DIAGNOSTIC UTILITY ABORTED -----
    And for your last question i can say that i have used the DAQ card on other laptops.But the results were the same.İ hope to see your reply
    Thanks,
    Serkan Buhan
    Electrical-Elecronics Engineer
    Researcher
    TUBITAK-BILTEN

  • DAQmx driver for DAQ 6009? Need DAQ Assistant in Block Panel palette.

    Do I understand things right?  The Ni USB DAQ 6009 is supported in DAQmx base and not DAQmx, or is this only true for the 6008? I need the DAQ Assistant in my LV 2009 Block Panel palette.  Do I go to my Ni-DAQmx 8.8 CDs, or do I download something.  Maybe I have the DAQmx base already?  I'm going to search my palette and NI Max.  I am also going to look at http://www.ni.com/support/daq/version_portable.htm#du.   If I'm going about this all wrong, please help.
    Thanks
    Norm

    Hi Dennis
    My DAQmx Cds are 8.8.  I don't  have a selection for the DAQ Assistant on my block panel palette, so I'm looking to get an update for my DAQmx driver for my USB 6009 DAQ that I'll be using with my  student software for LabVIEW 2009 version 9.0.  I've looked at a NI document "NI-DAQmx and NI-DAQ Driver Support: Portable Devices"  that was published on Jan 17, 2013.  It says for Windows 7 I should be using 9.6mx, but this document make no reference to a version of LabVIEW.  The date of the document is 1/17/13; maybe it is refering to  only to version LabVIEW 2013.  Can you help?  
    From what I've read I believe I need to use DAQmx and not DAQmx base, but I can't help wondering if the DAQmx base has something to do with the "NI DAQmx Device Basics" that I see on the right side of the screen when I'm in NI MAX getting ready to run the test panels.    ????? 
    Thank you for your time
    N.D.

  • Creating an application which uses NI-Daqmx driver

    Hello,
    I'm developing an application which uses NI-Daqmx driver and I need to deliver this application to end users.
    I currently have NI-DAQmx 9.7.0 installed on my computer which needed an installation of 1.55 GB.
    I got complaints from customers who want this application to run on a new machine without the need of installation of NI-DAQmx driver.
    My project contains the necessary dlls (NationalInstruments.Common.dll and NationalInstruments.DAQmx.dll) as referenced and I expect that build of the application along with these dlls work on a different machine somehow.
    Is there any way to provide such output that customers don't need to install NI-DAQmx?
    Do I have to add additional references to the project? If so, which ones should they be?
    Or can I have a smaller custom required installation of this driver which will not bother the customers?
    PS: I tried the output of the sample projects on a different machine which don't have NI-DAQmx installed. I got the same error.
    Thanks in advance.

    Greetings,
    You can have them install the DAQmx runtime engine which correlates with the version of DAQmx which is being used in the program you're distributing. This can be found on our website.
    Search "daqmx runtime engine x.x" and replace the x.x with your version number.
    Regards,
    Brandon V.
    Applications Engineer
    National Instruments 

  • Is Adobe Elements 10 compatable with Mac OX version 10.9.2 ?

    Is Adobe Elements 10 compatable with Mac OX version 10.9.2 ?
    I have just bought a new Mac and would like to know if Elements 10 will work on it please.

    flon
    I am strictly an Elements Windows user but try to find common ground between Premiere Elements Windows and Mac to give a viable response to Premiere Elements Mac questions.
    On this one, I suspect that the bottom line is going to be "try it" and see what happens in your specific computer environment.
    Please review the discussion in the following thread
    Re: Premiere Elements 10 crashes on disc templates
    Also, you are in for major display problems with Premiere Elements 10 on a computer that uses a NVIDIA GeForce video card/graphics card.
    There the fix is to roll back the driver version to May 2013 in order to get Premiere Elements 10 to function properly.
    Please review, consider, and then let us know the outcome when your schedule permits.
    Thank you.
    ATR

  • I am running Photoshop CC 2014 on Windows 8.1 with an AMD quad core processor and AMD E1-2100 APU with AMD Radeon HD 8210 Graphics Card. I have installed the latest driver version 13.152.0.0. When I activate puppet warp, the mesh appears over the image an

    I am running Photoshop CC 2014 on Windows 8.1 with an AMD quad core processor and AMD E1-2100 APU with AMD Radeon HD 8210 Graphics Card. I have installed the latest driver version 13.152.0.0. When I activate puppet warp, the mesh appears over the image and I can place the first pin.  However, when I go to add the second pin, Photoshop crashes. I have tried with on a new, blank file, with just a few lines on it, but, as soon as I place the first pin, the image disappears, and then, as soon as I click anywhere else in the image, Photoshop crashes. I have followed all the online advice about settings under the Preferences/Performance interface, but nothing fixes the problem. Can anyone please help?

    BOILERPLATE TEXT:
    If you give complete and detailed information about your setup and the issue at hand, such as your platform (Mac or Win), exact versions of your OS, of Photoshop and of Bridge, machine specs, such as total installed RAM, scratch file HDs, video card specs, what troubleshooting steps you have taken so far, what error message(s) you receive, if having issues opening raw files also the exact camera make and model that generated them, etc., someone may be able to help you.
    A screen shot could be very helpful too.
    Please read this FAQ for advice on how to ask your questions correctly for quicker and better answers:
    http://forums.adobe.com/thread/419981?tstart=0
    Thanks!

  • How to install the NI-DAQmx driver on a real time target PC?

    Hi, I’m painful about how I can install a PCI-6363 DAQmx on my real time desktop PC target. The PCI-6363 is directly connected to the real time PC. And I’m using LabVIEW 2011 and MAX 5.0. 
    The DAQmx device driver can be seen in software lIst in the host PC, but it can not be found in the install wizard. Is there something wrong with my host PC? or is that wrong to connect PCI-6363 with real time desktop PC?
    I would be grateful for any advice that I could get here.
    Solved!
    Go to Solution.

    Hi Zhleo,
    If you are about to use the PCI-6363 with the Real-Time Desktop you are right you need to have it installed, and then you need to deploy DAQmx driver software to the real-time target.
    To do that you access your real-time desktop under Remote Systems in MAX and start the Real-Time Software Wizard. There you should see DAQmx listed. 
    In case you do not have DAQmx listed there, see this KB: Deploying DAQmx to a Real-Time Controller or PC?
    Regards,
    Eirikur Runarsson
    Platinum Applications Engineer
    NI Denmark

  • FTDI VCP driver NI-DAQmx driver problem...

    Hi,
    I am making use of FTDI VCP driver on Windows XP to talk to a FT245R device (through USB interface).
    I also make use of NI USB-6251card to capture signal data [pulse wave form] and make use of NI-DAQmx driver S/W to talk to the device connected to the NI card.
    I observed that when there's no read/write happening on the FTDI VCP driver,  DAQmxReadAnalogF64() returns the right data. But where there's a read/write happening on the FTDI VCP driver,  DAQmxReadAnalogF64 returns corrupt data.
    This happens even if the read/writes to FTDI VCP driver and the  DAQmxReadAnalogF64 to the NI-DAQmx driver are in two different processes.
    Could you please let me know if there's any workaround?
    Thanks a lot!
    -Abraham

    Hi Ali,
    Thanks for your response.
    By Corrupt data, I mean wrong data points. So if I request 100 data point, I will get the data count as 100, but the values are junk values.
    I took your suggestion:
    I selected the test panels and aquired samples. When the FTDI VCP driver was not being exercies, I can see the correct wavefor [regular bi-phasic pulse] in the amplitude vs samples graph. But when there's activity on the FTDI VCP driver (read/write), then the graph shows junk waveform (most of it is close to zero).
    The Systems is a dual-core CPU.
    Initially we though it was due to CPU bandwidth, but looks like CPU is used some 60%.
    A collegue of mine suggested that it could be that when both the USB [NI and FTDI] draw power at the same time, we could get junk values.
    I also tried a USB hub and did not see any change - same bad values.
    I really appreciate your response.
    Thanks!
    -Abraham

  • Oracle RDB driver – Version 3.01.00.01 Connectivity Issue

    I have a SQL Server 2000 extended stored procedure connecting to an Oracle RDB data server via an ODBC connection (using Oracle RDB driver – Version 3.01.00.01). The SQL Server 2000 runs on a Windows 2000 Server.
    This extended stored procedure opens up multiple database connections and maintains them for processing. Usually, everything runs fine.
    However, every so often, we have connectivity issues. What happens is as follows:
    When we bring a station down and then try to reconnnect, our connection is denied, and we get the error: "recv() unexpected close Ret 0 Err#0 UNKNOWN Unknown WINSOCK Error 0". (This error is logged by the .dll running in the SQL Server processing space.) From the first time we receive a connectivity error like this until the Oracle RDB box is rebooted, we cannot establish another new ODBC connection to that Oracle RDB box --- whether we are trying to establish it programmatically or just via a "test connection" in the ODBC dialogue on the SQL Server box.
    We can, however, establish an ODBC connection to another, identically configured, Oracle RDB box from the SQL Server box (without restarting the SQL Server box).
    Has anyone had experience with instable connections from Windows system using the Oracle RDB driver to connect to the Oracle RDB? If not, can anyone point me in a direction that would help me research this? I am more familiar with SQL Server than Oracle, and the Oracle DBA on the other end isn't very accessible.
    I'd really appreciate any help anyone can give me.
    Thanks!

    I got same error.. Are you already solve that problem? how? please help me. Thanks

  • I need to use a Driver Version 1.4 for my my Sharp printer.  When I add the printer, it is driver version 1.3?

    I need to use Driver Version 1.4 for my Sharp printer.  When I add the printer it says Version 1.3?

    Have you asked Sharp whether they have a driver that is Mavericks compliant?

  • Driver Version Not Found" Error when installing drivers for X-fi Xtreme audio

    I recently bought the game Bioshock off steam and have been unable to play as it crashes as soon as I try to launch it. After doing some digging around I found out it was a sound problem. When I was looking at the drivers for my sound card (Sound Blaster X-Fi Xtreme Audio) I noticed that the driver called:?XFXA_PCDRV_LB__04_0079.exe has a fix for Bioshock. However when I install the driver I get the error "Driver version not found". I am positi've it is the correct driver for my sound card. I am on Windows 7 64bit.

    Hey!
    I have Vista Ultimate x64 and I ran windows update couple days ago. There was a new update for my xtreme audio pci-e. I installed it and now my driver version in creative software update is .3.2. Before i updated i ran creative's own software update. It didn't find any new drivers. I was WTF. I think that new driver fixed my volume problem. I had problem's when there was a deep bass in a song. The sound card lowered volume levels then somehow. Now that happens no more. In vista's device control it shows the driver version as 6.0.0.203. Driver date is 7 october 2008.

Maybe you are looking for

  • Import Duty 10% & Additive Cost

    Hi Guru, Is there possibilty to create % in additive cost. Eg Import need to be incorporate into the costing run of the raw material. If can, please advice how to do it and cannot advice how to bring this cost into the coting run. Hope to hear from y

  • OS 9 and MS Word ?

    Last week I downloaded a MS Office update. There are four sign-ons to the machine. When my daughter tries to load Word the machine says something about looking for OS 9 ? The other 3 sign-ons on the computer boot Word normally in OS 10.4.11. All othe

  • Entity Object ACCESSOR

    I use a view object VO1 which relies on 2 entity objects EO1 and EO2. Neither has been set to readonly in VO1. I set in EO2, a set metod (for one attributes) which use an accessor to EO1 (by its Association). When I insert an EO2 object on an existin

  • Multi Camera Function

    I use 6 cameras when shooting the local roller derby events. I currently use FCE and have to scale down the 6 video feeds to little boxes so they will all fit on the canvas, then choose which angle I am going to use, cut that section out of the time

  • Error code question

    I have a g4 which has stopped running and I need a little help. On start up it stops at the grey apple screen and doesn't boot up. I can boot up in target mode and are able to see the drive just fine. I ran an apple Hardware test and got a error code