hello to all
I built a test stand with three "card's" with the assistance of MAX (Measure & automation Explorer) virtual,
Now I want to make the following.
I want to write in Labview the name of some of cards. Of such form that soon Labview says to me. In where is this card and his data (information, chanel number, card number etc).
As I can make the inquiry, between Labview and max. It is possible using of Labview?.
Can I get these data with Labview without inquiry on MAX?
The goal of this program, it is to be able to identify the cards that are had installed, without having to use MAX.
can be solved to this problem using activex or Visa?. I believe that Visa requires of a hardware,but I am working with simulations ( I don't have a hardware).
[email protected]

Depending on what kind of "cards" you are using the ModInst vi's my do what you want.   They work with NI-SCOPE, NI-FGEN, NI-HSDIO, NI-DMM, NI-RFSG, and NI-SWITCH cards and will tell you the what of these devices you have installed, their name and attributes.  If your cards use different drives you will need another solution.
Brian

Similar Messages

  • Difference between Business Objects Explorer and Polestar

    Hi all,
    can anyone help me out with the main differences between Business Objects Explorer and Polestar.
    thanks & regards
    immanuel.

    Explorer is the new product name for Polestar.  There have been a few versions of Explorer released since it was called Polestar, but you can find the latest 'whats new' doc here which lists the latest additions:
    http://help.sap.com/businessobject/product_guides/boexplXI32/en/exp32_whats-new_en.pdf
    For one, Explorer now comes in two editions... Standard and Accelerated.  The Explorer Standard edition allows reporting off of Universes, just as the original Polestar product did.  Explorer Accelerated allows reporting off of SAP BWA indexes as well as Business Objects universes.  Both versions now allow uploading of excel files to report off of.  You can export an Information Space to a Webi doc or Excel file.  Users can now save favorite links to an Information Space.  Sorting has been improved as well as graphing functions and overall display.  You'll have to install the latest build of Explorer - "Explorer 3.2 SP1" and compare.  I don't know of a document or matrix that compares Polestar to Explorer.  The two are basically the same product with a number of enhancements added to the Explorer line.

  • Conectivity between existent SAP Systems and migrated system to MSCS Cluste

    Hi
    I have an existing SAP NW PI 7.0 (Abap + Java on Windows 2003 - SQLServer 2005) and plan to migrate to a cluster with new hardware (MSCS).
    I have to prepare for the installation by creating a homogeneous copy of the database but I'm a little bit confused.
    -Can I use backup/restore method or only can use import/export with R3load tools? The target system is windows and sql server same versions.
    -If I can use backup/restore... what is the rigth sequence to the installation? Can I use sapinst with mixed high availability options and System copy options?
    -I need to use in the target system the same hostname and IP address of the actual system, so in the Follow-Up Activities we do not change the configuration between the actual system (SAP NW PI) and other existent systems in the landscape... but I do not know what is the location in the cluster to this hostname and IP:
    *The central instance will be in the local disks in the node 1. Is the node 1 the rigth option to use the hostname and IP of the actual system?
    *The SAP Cluster group has a virtual hostname and IP, it has message and enqueu services. Is the sap cluster group he rigth option to use the hostname and IP of the actual system?
    How is the communication between the other systemas and the new clustered system?
    Thanks for your help

    Can I use backup/restore method or only can use import/export with R3load tools? The target system is windows and sql server same versions.
    You should follow the SAP guidlines in performing a homogeneous system copy.
    I need to use in the target system the same hostname and IP address of the actual system, so in the Follow-Up Activities we do not change the configuration between the actual system (SAP NW PI) and other existent systems in the landscape... but I do not know what is the location in the cluster to this hostname and IP
    This is not possible.  If you follow the SAP instructions for installing NW 7.0 in MSCS you will create two cluster groups: DBGroup and SAPGroup.  You will therefore have two virtual IP addresses, one for SAP cluster group and one for DB cluster group.  If you retain the current IP address/hostname for the virtual SAPGroup, you will need to follow the SAP guidelines for performing a SAP system copy to find where to change the database hostname/IP addresses to point to your new DBGroup.
    The central instance will be in the local disks in the node 1. Is the node 1 the rigth option to use the hostname and IP of the actual system?
    If you are meaning the ASCS then this should be installed on the disks that are part of the SAPGroup in the cluster.
    If you mean the dialog instance (or the Central Instance of a Java stack) then this can be on a local disk for node 1, and not in the cluster.
    The SAP Cluster group has a virtual hostname and IP, it has message and enqueu services. Is the sap cluster group he rigth option to use the hostname and IP of the actual system
    Yes, this will be the message server host for ASCS.

  • Issues between the Internet Explorer and Adobe acrobat

    Hello,
    Every time I click on a link in Internet Explorer, it goes and opens Adobe Acrobat 6 and this displays this error message:
    The Adobe Acrobat/Reader That is Running can not be used to view PDF files in a Web Browser.
    Please exit Adobe Acrobat/Reader and try again.
    How do I resolve this problem?
    Thanks in advance for the support.

    Hey Goyo1973,
    If the option is unchecked, check it and then try opening the PDF in browser. It should work.
    Cheers

  • Conection between 7.3.3 and 10g

    Hello world!
    I have 2 db. One is Oracle 10g (Windows XP, installed on my desktop) and another one is Oracle 7.3.3 (installed on the same desktop but on the virtual machine with Windows NT).
    I've tried to make connection from my 10g db (for instance, with sqlplus) but get this error message - ORA-03115.
    From doc -
    ORA-03115:     unsupported network datatype or representation
    Cause:     A user bind or define, or an Oracle function, is not supported by this heterogeneous Net8 connection.
    Action:     Upgrade the older version of Oracle and try again.
    It is possible somehow to maintain data exchange between those two versions.
    I interested in any ideas about bi-directional communication - even exp/imp.

    user9098610 wrote:
    The obvious question is "Why?" 7.3.3 is from a time when dinosaurs roamed the earth.The reason is quite simple - I have two systems - old one (on 7.3.3) and new system developed by our company.
    And data between those systems should be daily synchronised (at night). It is desire of our customer.It simply is not going to happen.
    I once had a system where we were stuck with an 8.1 client that had to connect to 10.2 database. It required 2 things:
    1) the 8.1 had to be patched up to terminal release (8.1.0.4??)
    2) we had to build an 8.1.0.4 database to act as a go-between. It had a db link to the 10.2, and and every app object in the 10.2 database had a corresponding synonym in the 8.1 db.
    Don't know if this will work in your situation or not. It's a real kludge. Hopefully your management is starting to see the false economy of not staying reasonably current on their databases. When I was running 7.3 databases (that was where I got started with Oracle) it was on Windows 3.1. Are you as far behind on OS as you are on databases? Or does your management think databases can fall behind while everything else is kept current?

  • Last query about Internet Explorer and Labview

    Hi there!
    Ok, I've managed to open URL in Internet Explorer from within LabView
    (thanks Dennis Knutson), but is there any way to include IE browser in
    a labview container to make it part of a project, without using
    ActiveX (coz compatibility troubles) ???
    thanks a lot!!!
    Mesca

    Mesca,
    Yes, but it is the long hard way. You can use the System Exec.vi to launch IE from the command line. If you give it a URL as a parameter on the command line (iexplore.exe http://www.ni.com), then IE will open that page. The downside to this is that this is all you can do. Once you launch the browser, it is a separate program that you have no hooks into. You would have to launch a new browser window for each page you want to launch.
    Randy Hoskin
    Applications Engineer
    National Instruments
    http://www.ni.com/ask

  • Measurement and Automation Explorer does not recognize two identical USB 3.0 cameras at once. How do I fix this?

    I am running a set up which uses 2 identical USB Point Grey cameras of the same model (FL3-U3-13S2M-CS). Both USB cameras are plugged into the computer (blue USB cables). 
    When I open up Measurement and Automation Explorer and look under "NI-IMAQdx Devices" in the configuration tree, LavVIEW only recognizes one of the two USB cameras. Measurement and Automation Explorer only lists one camera, in which it recognizes it as "Point Grey Camera". Why this is occurring? How can I get LabVIEW to recognize two separate cameras of the same model? 
    Attachments:
    PointGreyCamera.JPG ‏2847 KB
    DualUSB.JPG ‏2932 KB
    MeasurementAutomationExplorer.JPG ‏99 KB

    That's about the old NI-IMAQ for USB cameras. IMAQdx has built in support for DirectShow connected cameras. IMAQdx should be able to use more than one DirectShow camera at the same time, but the Point Grey DirectShow driver may have some issues.
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Difference Between Explorer and Explorer Accelerated?

    I was wondering if anyone could possibly give me links to documents that outline the differences between SAP Businessobjects Explorer and Businessobjects Explorer Accelerated. Or even just documents that outline their functionality without getting into techical specs too much.
    I have found a few, but they all seem to be too general or specific. I understand enough to get that the Accelerated version has an add-on that allows you to connect to your BWA blades, but are there any other differences?
    Thanks!

    Did you already check this book 'Inside SAP BusinessObjects Explorer' by Ingo Hilgefort?
    http://www.sap-press.com/products/Inside-SAP-BusinessObjects-Explorer.html
    Xavier

  • Help, Ni-Daq channel names and labview program error 10001?

    Can anyone please help me, I have inherited a role that I know nothing about. I have managed to get an NT pc to now recognise the SC-2345 board, set up and configure two channels and test them in Measurement and Automation program, this I managed after getting error 10401 and looking within these message boards which are very good.
    I have then started a labview program, previously written by ex-employee, and now get error 10001, after trawling the FAQ and forums I think that I have a naming error in the virtual channels created, how do I find out what the channels should be named within the Labview program, do I need to load an editor etc and then open a config file?
    Sorry if this seams like a simple error, but I am trying to learn the software from a book that is a little tattered.
    Regards

    Hi,
      error 10001 can be caused by a few things including an incorrect scanning order.
    If you'd like to post your code back onto here (or if it's large, ftp it to ftp.ni.com/incoming and let use know the name of the zip file you've packaged it into), then we can see what the DAQ section is supposed to be doing and hopefully provide some clues as to where to look for the information / why the error is occuring.
    The first thing to do is go back to Measurement and Automation explorer and try setting up a global task that refers to the channels you're interested in.
    This removes the programming side of things, since you select from drop down lists, to verify that you can communicate correctly with the hardware at the rates and across the channels that you want.
    These links is going to be your best learning point for getting up an running with the program.
    http://digital.ni.com/public.nsf/allkb/DD52ABD7C15F0B15862562910074F09E
    http://zone.ni.com/devzone/cda/tut/p/id/3116
    http://zone.ni.com/devzone/cda/tut/p/id/4656
    In terms of LabVIEW, there's several I/O controls you can use which will list the hardware channels you have configured or the global tasks you have created in Measurement and Automation explorer. (see the last link above)
    Another option is to look at our Alliance Partners if you need things configured and up and running in a hurry.
    http://www.ni.com/alliance
    If you just need a little pointer on getting kicked off, then you could see if you local sales engineer is available to go through things with you for an hour if they're in your area at a convenient time (for the UK / Ireland, please call in on 01635 572410 and ask to go through to sales), or we do offer start-up assistance (but that's something you need to purchase) to get a day's onsite assistance with getting your hardware up and running and starting you off with advice / examples on your application (note this is an effort based thing rather than a results based guarantee)
    Finally you could consider coming on one of our courses on LabVIEW and / or Data Acquisition to learn more about the software / hardware and be better prepared to handle the implementation yourself.
    Hope that helps
    Sacha Emery
    National Instruments (UK)
    Message Edited by SachaE on 03-23-2007 11:49 AM
    // it takes almost no time to rate an answer

  • Devantech USB-I2C converter and labview

    Hi,
    I bought a USB-I2C converter from Devantech. The driver sw installs a
    virtual COM port for the USB communication.
    With the demo program it works but I can not manage to get it to work with
    the Labview 6.1 serial vi's.
    Is there anybody who has experience with this?
    Regards,
    Marc

    bmw318 wrote:
    Hi,
    can you give me an example how to send a string command to it? I also tried hyperterminal but  not use... What am I doing wrong?????
    Marc
    Well there should be some documentation with the device that describes the commands you can send to it, to do the things it should do. We can not help you with that as we do not have that device.
    Once you get those commands you will probably want to use HyperTerminal to try and play with it a little. You can also go into Measurement & Automation Explorer and selecting your port you can use the Interactive Control Panel to do similar. If you have gotten some communication in that way and have an understanding of how the device works you can start coding in LabVIEW.
    Basically until you can get some basic communication with the device from HyperTerminal, trying to make it work in LabVIEW is wasted time.
    Rolf Kalbermatter
    Message Edited by rolfk on 03-10-2009 10:00 AM
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Linear actuator, motor controller and labview. Establishing connection.

    Overiew:
    I have a 12VDC linear actuator (potentiometer built in) connected to power and Jrk 21v3 USB Motor Controller with Feedback (http://www.pololu.com/catalog/product/1392). The USB motor controller connects to the computer through USB, actuator's feedback wires connect to the motor controller.
    Problem:
    Establishing connection between the motor controller and labview.
    What I have done so far:
    I installed drivers to the motor controller and windows detects it. NI MAX detects my motor controller (pic attached), but for some reason, when i try to access it through daq assistant in labview it doesnt see it. I also tried accessing it through VISA with no results..
    Help will be appreciated.
    Thanks
    Peter
    Solved!
    Go to Solution.
    Attachments:
    problem.jpg ‏124 KB

    You have a few things you need to look into:
    When you installed the software, did it install a USB > Virtual Com Port dll such as FTDIchip or similar? If so, when you hook up your device, it'll reveal itself as a normal (new) Com Port in Device Manager. You then need to try to talk to that com port.
    If you are trying to use the native USB on the board (as MAX has detected for you), then you'll need to use the .NET framework code provided by the manufacturer (probably written in C#), and make your own Constructors in LabVIEW. If you've never done this, it isn't trivial.
    I would call the manufacturer and just tell them what you are trying to do. They've probably dealt with LabVIEW before, and may have an example to get you started.
    edit: For fun, I followed the link you provided (which doesn't really work). I searched their site for "LabVIEW", and indeed got several hits. This one thing I downloaded (can't resist looking at code) was a gigantic turd ball. However, it did appear to use a normal Com port.
    Richard

  • Id like to be able to initialize my 7344 Motion Controller card from within Labview and not through motion and automation explorer

    Every time I boot my PC , I have to reinitialize my 7344 through Motion and Automation Explorer  in order for it to work. Does anyone have any suggestions as to how to initialize it from within labview itself?
    thanks

    Hi,
    I am sending you a Vi for initializing the controller.The only thing you have to do is that you need to use sequence structure. In the first sequence you need to use the VI which is attached i.e 0 (default). Then the next sequence will be the program itself.
    So that as soon as you run your vi the first thing done will be initialising controller using LabVIEW. Then your program will run.
    Here the led in the front panel will glow green only the first time you are initializing.The next time it will be dim but no doubt your initializing will be taking place.Hope this vi solves your problem.
    Thxs
    Manish Karnik
    Application Engineer
    Cruiser Controls
    Mumbai, India. 
    Attachments:
    Initializing controller.vi ‏42 KB

  • Problems with Measurement and Automation Explorer (MAX)

    Hello LabVIEWers,
    I have been having a serious problem getting MAX to start and to remain stable. Here are the specifics:I am running LabVIEW 8.5 Full Development System on a Dell PC with 1GB of RAM and plenty of hard drive space. The OS is XP Pro and I also have McAfee Enterprise Virus Scan software.  MAX will start-up and appear to run for a few minutes and then the software bombs out. I get a "Measurement and Automation Explorer has encountered a problem and has to close" pop-up message. To fix the problem, I have uninstalled all NI software using MSI Blast. I have wiped the registry clean of NI keys as per instructions in previous posts. I have deleted any remaining NI software on teh hard drive including C:\program files\national instruments and C:\Documents and Settings\All Users\Application Data\National Instruments. I have then restarted the machine and did a complete fresh install from CD's, DVD's, and the harddrive (CD's written to hardrive and DVD written to harddrive first). I installed first the LabVIEW and then I installed the Device Drivers. I restarted the machine between installs. I have even installed the updated NIDAQ 8.6. After which I set protections on the NI directories to read/write. Ok, basically I have done all these things numerous times and I still cannot get things to work correctly.
    I was able to get into MAX for a little while (it is somewhat stable immediately after a fresh reinstall). I defined 4 Simulated DAQmx devices and none of them acted like they were simulated. I received various errors saying that the device was not found or could not be started. So I basically could not run my software with the simulated devices. LabVIEW sometimes seems to work ok but just now, I got a "Error loading nidmm_32.dll, initialization routine failed" error. I also get the same error for nilvaiu.dll. Both of these DLLs are in the C:\Program Files\IVI\Bin and  c:\windows\system32 directories respectively and prior to the last time I started the software, all worked ok with LabVIEW.
    Is my computer failing? Are there any other options to getting this installed without probems?
    Please help.
    Michael Froehlich

    Duplicate Post
    Keep discussion here
    National Instruments
    WSN/Wireless DAQ Product Support Engineer

  • How can I get all the options of Field Point Explorer 3.0.2 in Measuremen​t and Automation Explorer 3.1?

    I am a student using LabVIEW and Compact Field Point to implement a
    senior design project in Electrical and Computer Engineering.  We
    have LabVIEW 7.1 and a cFP-2020 and additional modules.  We are
    trying to use the CTR-500 module to output a pulse train to drive a
    stepper motor.  We have found instructions online of how to do
    this, but they all use Field Point Explorer.  The instructions
    make use of options in Field Point Explorer that are not included in
    Measurement and Automation Explorer (the software included with the
    cFP).
    I have downloaded Field Point Explorer 3.0.2 and followed the
    directions.  Now, in LabVIEW, when I using the newly created .iak
    file, I get a dialogue asking to find the SubVI: 'FP Read (Float Array
    -IO).vi'.  Included with LabVIEW are subvis for FP Read, but not
    with the float array part.  So I figure I cannot use Field Point
    Explorer created .iaks with LabVIEW 7.1.  So how cannot I access
    the same options in Measurement and Automation that I was able to find
    in Field Point Explorer?
    Thanks

    Hi,
    FieldPoint Explorer is no longer used to configure FieldPoint systems. However, I do not think that the configuring your system in FieldPoint Explorer is causing the error.
    FieldPoint systems are now setup in Measurement and Automation Explorer (MAX).  Information on setting up FieldPoint systems in MAX can be found in the MAX help under: Installed Products>> FieldPoint. Also, I recommend upgrading to the latest FieldPoint driver and version of MAX.  The FieldPoint VI's will be slightly different when you upgrade, so there is a good chance that this will eliminate the error.
    Regards,
    Hal L.

  • Is it possible to change the resolution of indivdual channels in measurement and automation explorer using a VI

    Hi
    I'm acquiring data on 8 analog input channels using a PCI-6052 E card. The data on channels 5 thru 8 is going to be between +1V and -1V. So for greater resolution I'm manually changing the range of these channels to +1V to -1V in the measurement and automation explorer. Is there a way by which I can make these changes directly using a VI ?
    Thanks,
    Shiv

    Hi
    Yes you can, but only if you use the "AI Config" VI. AI config allows different gains for different channels. The "channels" and "input limits" inputs of the VI accepts arrays. The first element of the input limits array corresponds to the first element of the channel array. Check the "cont acq&chart (buffered).vi" in the LV examples. There you see what I mean!
    Regards,
    Luca

Maybe you are looking for

  • LabVIEW Programming

    I would like to know how to specify the position of more than one cursor in an XY graph programmatically. Is there a propoerty node that can select each cursor in a graph based on their name?? Thank you

  • Canvas problem on a s60 device

    Hi i am having a problem displaying a canvas on top of the previous canvas that was displayed. basicly i have tow canvas, one is a full screen canvas and the otehr is simply a rectangle box witha txt inside... on the default colour phone emulator i c

  • HTTP Post CGI script

    I don't want to write a server, I'd just like to have the MIDlet call a CGI script to transmit some formatted UDP data to a chat server. So basically the packet will send a command to the chat server, and the chat server will return with a single str

  • Analytical Workspace Manager Script

    I am using AWM to build and maintain my OLAP cube. Up until now, I've been maintaining the cube by hand (via the maintenance wizard). I'd like to set automatically maintain my cube every night. I used the maintenance wizard to automatically create a

  • Remote Access on Home Network

    I have two Macs running 10.5.3. One is a MacBook Pro, the other is a Power Mac G4 tower upgraded w/ a dual-1.6ghz processor. When the G4 was running Tiger, I had no problem accessing it from the MacBook Pro. I could share the G4 screen and manage its