Connecting to a remote computer

Hi all,
I have recently started working on a website using
dreamweaver. I don't have a good experience building website. I
need to connect to a emote computer to download data sitting there.
The data is stored as a text file. I need to doknow how to do that
with both option, i mean if there is a fire wall or with a
firewall.
Thanks!!

Well, the two that are networked, you could set up a 'shared'
directory, so
that either or both computers can read and write to, then
simply store this
file in this directory and both can get to it whenever.
As for the remote computer not networked to yours, well
unless you have
physical access to it, to get it onto a flash drive, portable
hard drive
etc, you are looking a bit limited, without email. Unless you
can get the
person to set up some sort of ftp access or the like, shared
directory with
password access, you might be SOOL.
Cheers,
Brendon
ps. there may be other options, but they allude me at the
moment.
"Orhan_a" <[email protected]> wrote in
message
news:ea2k51$rhc$[email protected]..
> Yes, the two computer are netwroked. no i can't email
the text file from
> the
> remote computer. Also, i need to know how to download
text file from a
> remote
> comuter which is not networked with mine. i might need
it soon.
>
> Thanks alot!!
>
>
>

Similar Messages

  • Windows VPN: Error 720 - A connection to the remote computer could not be established

    Dear all
    I have a windows7 Laptop 64bit Dell 1340.
    I was working with a UMTS card, was connected with a VPN to a windows 2003 server over PPTP and experienced a bluescreen. After this, I have the following errors when connecting to the VPN:
    "Registering your computer on the network... Error 720: A connection to the remote computer could not be established. You might need to change the network settings for this connection"
    and in the event view I receive the following:
    EventID: 1, Source RasSstp
    CoId={A3478DFD-FFA4-4E8F-9DA3-CE829BDA777B}:The initial Secure Socket Tunneling Protocol request could not be successfully sent to the server. This can be due to network connectivity issues or certificate (trust) issues. The detailed error message is provided below. Correct the problem and try again.
    I tried to use the Rarepair.exe tool but it looks to work only on windows xp. I deleted the IP and TCP settings without any luck.
    I run a registry cleaner as well with out any luck.
    Your help will be greatly appreciated!
    Marc

    Hi,
    Since it worked previously, a quick solution is to run System Restore and get back to the previous status when the issue didn’t occur.
    If system restore doesn’t help, please also try the following:
    1.    Check if you can establish the VPN via other connections except the connection through the UMTS card.
    2.    Reset the PPTP and L2TP WAN miniport with running the following commands one by one in an elevated command prompt:
    Netcfg -u MS_L2TP
    Netcfg -u MS_PPTP
    Netcfg -l %windir%\inf\netrast.inf -c p -i MS_PPTP
    Netcfg -l %windir%\inf\netrast.inf -c p -i MS_L2TP
    Then reboot the computer and see how it works.
    Meanwhile, I would like to share the following with you for your reference:
    Troubleshooting common VPN related errors
    Hope this helps. Thanks.
    Nicholas Li - MSFT

  • BB Torch - bluetooth tethering for laptop internet use: "Error 720: A connection to the remote computer could not be establishe​d

    Trying to set up Blackberry Torch for laptop tethering...bluetooth. I have connection/drivers/etc. but keep getting error message: "Error 720: A connection to the remote computer could not be established. You might need to change the network settings for this connection." Where and what do I chancge setting to so this will work?
     I have synched my phone and laptop wirelessly across other internet connection....just cant get this above to work. Anybody know how to fix this? Thanks!

    Hi,
    Since it worked previously, a quick solution is to run System Restore and get back to the previous status when the issue didn’t occur.
    If system restore doesn’t help, please also try the following:
    1.    Check if you can establish the VPN via other connections except the connection through the UMTS card.
    2.    Reset the PPTP and L2TP WAN miniport with running the following commands one by one in an elevated command prompt:
    Netcfg -u MS_L2TP
    Netcfg -u MS_PPTP
    Netcfg -l %windir%\inf\netrast.inf -c p -i MS_PPTP
    Netcfg -l %windir%\inf\netrast.inf -c p -i MS_L2TP
    Then reboot the computer and see how it works.
    Meanwhile, I would like to share the following with you for your reference:
    Troubleshooting common VPN related errors
    Hope this helps. Thanks.
    Nicholas Li - MSFT

  • Error 720: A connection to the remote computer could not be established.

    So I got an aircard Novatel P720. It was working fine for months. Then I installed a VPN connection. Now, I get this error.
    Error 720: A connection to the remote computer could not be established.
    Most of of what I found recommends uninstalling the WAN Miniport (IP), it seems that  I have to go thru so many hoops to get this fixed. Wondering if I would be better off rebuilding my machine from scratch again. Is there an patch or another way to get me going.
    I think this is an old issue. Lots of comments on this thru Google. I am hoping I can get a definative answer from Lenovo's itself!

    josezald wrote:
    So I got an aircard Novatel P720. It was working fine for months. Then I installed a VPN connection. Now, I get this error.
    Error 720: A connection to the remote computer could not be established.
    Most of of what I found recommends uninstalling the WAN Miniport (IP), it seems that  I have to go thru so many hoops to get this fixed. Wondering if I would be better off rebuilding my machine from scratch again. Is there an patch or another way to get me going.
    I think this is an old issue. Lots of comments on this thru Google. I am hoping I can get a definative answer from Lenovo's itself!
    Well, seeing since your having an Issue with a non Lenovo product. I dont think your going to get an official answer from Lenovo. You may get suggestions however. 
    Ignorance is no excuse!

  • Error 720 a connection to the remote computer could not be established win 8

    hello, i have this error on my windose 8, error 720 a connection to the remote computer could not be established ,for VPN connection,  how can i fix it ? 

    Hi,
    For this issue,I would like to know your VPN protocol.
    Did you use Windows in-built VPN client?
    I think the issue is related to your security software or Firewall.
    Let’s temporarily disable other security software and Windows firewall to check if that helps.
    If it doesn't work, please uninstall the third-party security software or firewall to test it.
    Also, please check your event view to see if there are some related error in it.
    Regards,
    Kelvin hsu
    TechNet Community Support

  • Client could not establish a connection to the remote computer

    Sir we are using Windows 2008 Server standard licence edition and using Microsoft Cal open licence  (Total 25). Our system are working from smoothly from 1 years. But from one week we have facing client could not establish a connection to the remote
    computer.
    Sir I am talking from Integral Bank, Jaipur Sir please solve our problem.
    With warm regards,
    Hariom
    M-09875156100
    mail : [email protected]

    Sir we are using Windows 2008 Server standard licence edition and using Microsoft Cal open licence  (Total 25). Our system are working from smoothly from 1 years. But from one week we have facing client could not establish a connection to the remote
    computer.
    Sir I am talking from Integral Bank, Jaipur Sir please solve our problem.
    With warm regards,
    Hariom
    M-09875156100
    mail : [email protected]

  • Hyper-V 2012 R2. RemoteFx. "The remote session was disconnected because there were network problems during the licensing protocol. Please try connecting to the remote computer again."

    After a Installation from Windows 8.1/windows 7 everything works fine. For example  Install updates and Software. If I connect the first time a remotefx card i can use RDP as well. But if i restart the host I get the mentioned error. What can I do. These
    Hosts are not in a domain configuration. I tried it too but there was  no difference. I didn't discovered any errors in the eventlog, too. Only an actviex error. But same errors occurs with a succsefull rdp session.
    Also strange is if i start the vm without a remotefx card it works fine again. Only session with a Remotefx card aren't possible anymore.
    Is there a bug or something. I tried it many times with the same error.
    Maybe someone can help me. 
    kind regards  
    Tobi

    Hi Tobi,
    Thank you for posting in Windows Server Forum.
    For a workaround, please try to perform the two steps.
    1. Do NOT enable RDP 8 on the Windows 7 SP1 VM.  You should install RDP 8 and update the ICs though.
    2. Change the connection setting on the client from "Automatically detect" to "LAN"
    Please check again below thread for information.
    a. "The remote session was disconnected
    because there were network problems during the licensing protocol" after enabling RemoteFX Windows 8 VM
    (Please recheck answer by “dgeddes”)
    b. "The remote session
    was disconnected because there were network problems during the licensing protocol" After Installing RemoteFX
    Hope it helps!
    Thanks,
    Dharmesh

  • Connecting from a remote computer / name resolution issues

    My work has two SQL Server 2005 databases, one installed on a Windows XP machine (running some equipment) and one installed on a Windows 7 machine (backing up the files from the XP instance).  Both computers run only the default instance.  I had
    replication set up and functioning (data being created on the XP maching was being replicated to the Win 7 machine) for the last three weeks in July.  I recently noticed that the replication is no longer working (the files were no longer being copied),
    and when I tried to check the status I got an error about named pipes, or, if I disabled named pipes "tcp provider error 0 no such host is known".
    At the time I found the replication problem, I could connect to both databases through SSMS on the Windows 7 machine.  On the XP machine, I could use SSMS to browse to the Win 7 instance but SSMS would not connect to the Win 7 instance by name (same
    errors about no such host known); the connection does go through by IP address.  I can ping from the Win 7 machine to the XP machine both by IP address and by name.  I could ping from the XP machine to the Win 7 machine by IP address but NOT by name.
    I tried running the workgroup wizard on the XP machine, thinking this might help with the name resolution problem.  In the wizard, I changed the workgroup name to a new name.  I changed the workgroup name on the Win 7 machine to match.
    This change did not affect the ping status - I can still ping by both name and IP address from the Win 7 machine, and still only the IP address works from the XP machine.  However, now SSMS on the Win 7 machine no longer sees the XP machine!  Trying
    to log in with either the machine name and the IP address, I now get a "timeout expired" message, and the SSMS login browser does not show the XP machine on the network.
    Any pointers on where to look for the cause of this problem would be very welcome.

    There was some problem (bug?) with the remote connections flag on the Win 7 server.  Someone had posted in the comments to a technet article that unchecking the remote connections box, restarting the server, then re-checking it helped them.  I
    tried it, and that fixed the problem with the Win 7 machine being unable to see the XP machine.
    Olaf's suggestion about the Hosts file fixed the problem with the XP machine having to use the IP address - now it can connect by name as well.
    Now I just have left the problem of a broken subscription to my replication, but that's a separate issue so I'll consider this thread closed.  Thanks to everyone who offered suggestions.

  • Connection to the remote computer by socket

    the computer which i want to access from my home is the computer of mine in the company. and i want to do this with socket programming.i will execute a java program listening the port 5101 for example at work.
    my intranet IP is 10.10.20.84 (i think this is private IP)
    but if i visit;
    http://www.ilanonurajans.com/ip_ogren.asp
    the IP is different from this (i think this is the public IP)
    so how can i create the socket?
    Socket clientSocket=new Socket("***.***.***.***",5101); //public one
    or
    Socket clientSocket=new Socket("10.10.20.84",5101); //private one
    thanx

    Let me see if i understand you correctly you want to access your work pc from your home pc right? So the serverSocket will be on your work pc.
    IF this is the case it won't be easy to do so. This is because you are behind something known as a NAT (network adress translation). Since you have a different public and private ip you can't reach your pc from outside of the internal network. The only way to accieve this is if you have access to the router that manages your nat at work and make it foreward all incomming connections on your port to your pc. If you do that you need to do
    Socket clientSocket=new Socket("***.***.***.***",5101); //public one
    If you can't configure the router there is no way to do what you want.
    HTH
    Lima

  • VPN ERROR 619 :: A connection to the remote computer could not be established, so the port used for this connection was closed

    I have been searching endlessly for this issue. Every time I try to connect to a VPN connection I get the error above. Thank you for any relevant input concerning this matter. My NIC is Qualcomm Atheros and I'm in Win8.1 x64.

    everything normal before?
    is there any changes before this issue happen?
    turn off your antivirus and firewall, update the latest VPN client software, if still not working go to security settings and change the VPN type automatic to PPTP. And also change data encryption configuration to Optional and select CHAP & MS-CHAP v2.
    If still not working try with other internet connection and try to contact your VPN provider

  • HT2452 i downloaded a new java - but having problems connecting to a remote computer. how can I go back to how my imac was configured 2 hours ago?

    greetings.
    is there a way to restore my iMac to how it was 2 hours ago? kinda like a system restore in PC if I wanted to revert back..  any ideas?  I downloaded a new Java and I dont know how to configure it.  When trying to log into my work computer it said old version of Jave not supported but earlier in the day I had no problems.  Now I can't get past the launch page on my SecureID -  does this sound familiar to anyone or is it foreign??  Not sure if i need to call my comapany's desktop support

    Hi Bill,
    Locate the version of Java that’s installed on your Mac OS X system.
    1. Open the Utilities folder and run the Terminal application.
    2. Type java -version and press Enter.
    (space between java & -v important)
    The version of Java that you have installed will then be displayed on the screen.
    Java for OS X 2012-006: How to re-enable the Apple-provided Java SE 6 applet plug-in and Web Start functionality
    http://support.apple.com/kb/HT5559

  • Rsh - connecting using user name that does not exist on remote computer

    hi
    is it possible to connect to a remote computer as, for example John, if user account John does not exist on the remote computer but is listed in .rhosts?
    this is what i have written in .rhosts on the remote computer ( Work ):
    home root
    home John
    when I connect as root:
    rlogin -l root Work
    everythings fine, but when I try to connect as John I get the incorrect login message
    I know the message above probably answers my question, but I want to be sure

    If the user id exists, you can bypass the authentication with .rhosts or /etc/hosts.equiv files; but you can't login to a remote machine as an anonymous user.

  • No more connections available to this remote computer...Urgent Help for File server...

    Hi Guys,
    I need urgent help regards to our school File server which is having "No more connection to this remote computer error"
    on SMB Shares where I usually authenticate with a domain username it used to work fine since till 3 weeks ago.
    Now I can browse the SMB shares with only IP... Netbios gets straight away this error message from non-domain joined pc's where the computer needs to connect to the SCCM distribution point on this file server.
    Strangely, Domain joined pc's does not have this problem at all they can use Netbios or IP no problem at all. But someone from a standalone laptop or desktop who needs to access shares through netbios gets this message.
    Can someone help me please?
    I did check DNS yet there is no problem on DNS I checked PTR record for the server to make sure it is not turned in to multihome accidently but nothing at all.
    I also did a NETMON where I captured the data from server and the client I get these errors:
    205 4:54:35 PM 16/12/2013
    7.3299179 10.2.1.96
    10.2.0.13 TCP
    TCP:Flags=......S., SrcPort=49312, DstPort=Microsoft-DS(445), PayloadLen=0, Seq=1771710719, Ack=0, Win=8192 ( Negotiating scale factor 0x2 ) = 8192
    {TCP:22, IPv4:21}
    206 4:54:35 PM 16/12/2013
    7.3299668 10.2.0.13
    10.2.1.96 TCP
    TCP:Flags=...A..S., SrcPort=Microsoft-DS(445), DstPort=49312, PayloadLen=0, Seq=2167618331, Ack=1771710720, Win=8192 ( Negotiated scale factor 0x8 ) = 2097152
    {TCP:22, IPv4:21}
    207 4:54:35 PM 16/12/2013
    7.3301468 10.2.1.96
    10.2.0.13 TCP
    TCP:Flags=...A...., SrcPort=49312, DstPort=Microsoft-DS(445), PayloadLen=0, Seq=1771710720, Ack=2167618332, Win=16425 (scale factor 0x2) = 65700
    {TCP:22, IPv4:21}
    208 4:54:35 PM 16/12/2013
    7.3301468 10.2.1.96
    10.2.0.13 SMB
    SMB:C; Negotiate, Dialect = PC NETWORK PROGRAM 1.0, LANMAN1.0, Windows for Workgroups 3.1a, LM1.2X002, LANMAN2.1, NT LM 0.12, SMB 2.002, SMB 2.???
    {SMBOverTCP:23, TCP:22, IPv4:21}
    209 4:54:35 PM 16/12/2013
    7.3307974 10.2.0.13
    10.2.1.96 SMB2
    SMB2:R   NEGOTIATE (0x0), GUID={8447F237-5219-D48A-40C0-29092450C68E}
    {SMBOverTCP:23, TCP:22, IPv4:21}
    210 4:54:35 PM 16/12/2013
    7.3314064 10.2.1.96
    10.2.0.13 SMB2
    SMB2:C   SESSION SETUP (0x1) {SMBOverTCP:23, TCP:22, IPv4:21}
    211 4:54:35 PM 16/12/2013
    7.3318815 10.2.0.13
    10.2.1.96 SMB2
    SMB2:R  - NT Status: System - Error, Code = (22) STATUS_MORE_PROCESSING_REQUIRED  SESSION SETUP (0x1), SessionFlags=0x0
    {SMBOverTCP:23, TCP:22, IPv4:21}
    212 4:54:35 PM 16/12/2013
    7.3324012 10.2.1.96
    10.2.0.13 SMB2
    SMB2:C   SESSION SETUP (0x1) {SMBOverTCP:23, TCP:22, IPv4:21}
    215 4:54:35 PM 16/12/2013
    7.3339977 10.2.0.13
    10.2.1.96 SMB2
    SMB2:R  - NT Status: System - Error, Code = (109) STATUS_LOGON_FAILURE  SESSION SETUP (0x1)  
    {SMBOverTCP:23, TCP:22, IPv4:21}
    216 4:54:35 PM 16/12/2013
    7.3341805 10.2.1.96
    10.2.0.13 TCP
    TCP:Flags=...A.R.., SrcPort=49312, DstPort=Microsoft-DS(445), PayloadLen=0, Seq=1771711788, Ack=2167619070, Win=0 (scale factor 0x2) = 0
    {TCP:22, IPv4:21}
    217 4:54:35 PM 16/12/2013
    7.3357089 10.2.1.96
    10.2.0.13 TCP
    TCP:Flags=......S., SrcPort=49313, DstPort=Microsoft-DS(445), PayloadLen=0, Seq=2943201172, Ack=0, Win=8192 ( Negotiating scale factor 0x2 ) = 8192
    {TCP:27, IPv4:21}
    218 4:54:35 PM 16/12/2013
    7.3357422 10.2.0.13
    10.2.1.96 TCP
    TCP:Flags=...A..S., SrcPort=Microsoft-DS(445), DstPort=49313, PayloadLen=0, Seq=3718656547, Ack=2943201173, Win=8192 ( Negotiated scale factor 0x8 ) = 2097152
    {TCP:27, IPv4:21}
    219 4:54:35 PM 16/12/2013
    7.3359768 10.2.1.96
    10.2.0.13 TCP
    TCP:Flags=...A...., SrcPort=49313, DstPort=Microsoft-DS(445), PayloadLen=0, Seq=2943201173, Ack=3718656548, Win=16425 (scale factor 0x2) = 65700
    {TCP:27, IPv4:21}
    220 4:54:35 PM 16/12/2013
    7.3359768 10.2.1.96
    10.2.0.13 SMB2
    SMB2:C   NEGOTIATE (0x0), GUID={8213462D-2600-D1B1-11E3-65FC4BCDE707}
    {SMBOverTCP:28, TCP:27, IPv4:21}
    221 4:54:35 PM 16/12/2013
    7.3364173 10.2.0.13
    10.2.1.96 SMB2
    SMB2:R   NEGOTIATE (0x0), GUID={8447F237-5219-D48A-40C0-29092450C68E}
    {SMBOverTCP:28, TCP:27, IPv4:21}
    222 4:54:35 PM 16/12/2013
    7.3369702 10.2.1.96
    10.2.0.13 SMB2
    SMB2:C   SESSION SETUP (0x1) {SMBOverTCP:28, TCP:27, IPv4:21}
    223 4:54:35 PM 16/12/2013
    7.3373474 10.2.0.13
    10.2.1.96 SMB2
    SMB2:R  - NT Status: System - Error, Code = (22) STATUS_MORE_PROCESSING_REQUIRED  SESSION SETUP (0x1), SessionFlags=0x0
    {SMBOverTCP:28, TCP:27, IPv4:21}
    224 4:54:35 PM 16/12/2013
    7.3377060 10.2.1.96
    10.2.0.13 SMB2
    SMB2:C   SESSION SETUP (0x1) {SMBOverTCP:28, TCP:27, IPv4:21}
    227 4:54:35 PM 16/12/2013
    7.3390552 10.2.0.13
    10.2.1.96 SMB2
    SMB2:R  - NT Status: System - Error, Code = (109) STATUS_LOGON_FAILURE  SESSION SETUP (0x1)  
    {SMBOverTCP:28, TCP:27, IPv4:21}
    Regards,
    Gokhan

    Solution has been found, 
    After doing bit of a backtrack, site DC's were out of sync with PDC with time.
    Also Time service was shutdown on PDC which has been enabled and pointed to the Australian pool ntp IP address.
    Everything is back on track now.
    Regards,
    Gokhan Cil

  • JDBC connect from remote computer fails

    Hi all,
    I have successfully installed the XE server and I can connect over JDBC from clients running locally on the machine where the XE server is installed.
    However when I try to connect from a remote computer using the same client I get an error saying: The Network Adapter could not establish the connection
    I can ping the machine with XE installed and all firewalls on the machines are turned off.
    Any ideas on the subject of JDBC remote connect to XE server? Or is it simply that it is not supported?
    Appreciate all the help I can get.
    Thanks,
    /Anders

    On my machine I have the listener bound to local interface.
    Listener.ora has hostname in it, and this is the listener status:
    As status shows the hostname is resolved to localhost, on this machine I am unable (with this configuration) to share the db to other machines (I do not have oracle client on my other pc, but telnet is unable to connect to port 1521).
    Changing hostname to ipaddres solves.
    [andrea@bones ~]$ lsnrctl status
    LSNRCTL for Linux: Version 10.2.0.1.0 - Beta on 15-DEC-2005 21:28:51
    Copyright (c) 1991, 2005, Oracle.  All rights reserved.
    Connecting to (DESCRIPTION=(ADDRESS=(PROTOCOL=TCP)(HOST=bones)(PORT=1521)))
    STATUS of the LISTENER
    Alias                     LISTENER
    Version                   TNSLSNR for Linux: Version 10.2.0.1.0 - Beta
    Start Date                15-DEC-2005 21:28:40
    Uptime                    0 days 0 hr. 0 min. 11 sec
    Trace Level               off
    Security                  ON: Local OS Authentication
    SNMP                      OFF
    Default Service           XE
    Listener Parameter File   /usr/lib/oracle/xe/app/oracle/product/10.2.0/server/network/admin/listener.ora
    Listener Log File         /usr/lib/oracle/xe/app/oracle/product/10.2.0/server/network/log/listener.log
    Listening Endpoints Summary...
      (DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)(HOST=localhost.localdomain)(PORT=1521)))
      (DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)(HOST=localhost.localdomain)(PORT=8080))(Presentation=HTTP)(Session=RAW))
    Services Summary...
    Service "PLSExtProc" has 1 instance(s).
      Instance "PLSExtProc", status UNKNOWN, has 1 handler(s) for this service...
    Service "XE" has 1 instance(s).
      Instance "XE", status READY, has 1 handler(s) for this service...
    Service "XEXDB" has 1 instance(s).
      Instance "XE", status READY, has 1 handler(s) for this service...
    Service "XE_XPT" has 1 instance(s).
      Instance "XE", status READY, has 1 handler(s) for this service...
    The command completed successfully
    [andrea@bones ~]$

  • How do I read and write to text files on a remote computer's hard drive

    I would like to read and write data to a text file on a remote computer. This is easily accomplished using one of the file functions such as "write characters to file.vi". If I am already connected to the remote computer, all I need to do is specify the path to the particular file and it will work fine.
    My problem is that I want to connect to the remote computer programatically within LabVIEW (I do not want to have to use the computer's OS to establish the connection. Is there a function that I can use to do this?
    Thomas D. Schaefer
    Wells Manufacturing Corp

    Yariv,
    You should really start a new thread with a new question like this, so that more people see it. Some people look primarily at threads that have no responses yet. Also, don't post the exact same question in multiple places. Or, if you must cross-post to some other forum, make sure to mention it in your question text.
    I'm happy to be a brick in your Western Wall, but I'm not sure what the main objective is here. Is the main problem really getting access to the "X bytes received in Y seconds at Z bytes/sec" string? Or is it accomplishing the file transfer? And what OS and LabVIEW version are you running?
    I think your problem is that you the LabVIEW System Exec command does not allow for the degree of interactivity that you need if you want to issue a sequence of commands to a command-line executable. However, under Windows XP (and, presumably, other Windows versions, though I can't check), you can tell the FTP executable to use commands from a textfile script by using the -s switch, and you can override the prompts during multiple file transfers with the -i switch:
    ftp -i -s:FILEPATH SERVERNAME
    If you issue a command in this format to System Exec, and make sure to create a file at FILEPATH with your command sequence (one per line), then you should at least accomplish the FTP actions. This won't give you the transfer details in the standard output, unfortunately. However, if you just want a general sense of how much was transferred and how quickly it happened, you can code that in LabVIEW by getting the resulting file sizes and using Tick Count before and after the System Exec call to see how long the transfer took.
    Hope that helps,
    John

Maybe you are looking for

  • Moving a folder in applications to external hard drive

    Hello! So background story: I recently started moving all of my photos, music, and video library from my Macintosh HD to my external hard drive. I do have my Adobe CS4 suite installed on my Mac HD, and it is a folder inside 'Applications.' So here is

  • PM G4 867 PCI Slot - PCI 2.2 Compatability Question

    Does anyone know if a PCI 2.2 card will work on the PowerMac G4 867. I know the bus rating is 33 mhz, but I am not sure if a 2.2 card will work. Thank you to all who respond. PowerMac G4 867   Mac OS X (10.4.6)   Alt Machine: iBook 900 OS X (10.4.6)

  • Unbale to move the stock...Urgent

    Hello Friends Stock is transferred to other plant. In the said PO stock type was mentioned as "Quality Inspection", as a result material lying in Quality inspection. Unfortunately there was no Inspection Plan for said material hence Inspection was no

  • Field error when generated to pdf file

    hi all, please help. I have an oracle report generated which will show numeric figures out. eg. 500.00 when this report generated to pdf file, the numeric figures field becomes 4835.50. Does anyone comes across this issue? i checked with my software

  • How do I install PSE 11?

    I keep getting the "encountered an error while installing shared technologies". I had the program working a couple of weeks ago but then it stopped loading. I uninstalled and since have been unsuccessfully trying to re-install. Any ideas please?