Datasource replication if systems changes

Hi All,
I have a CRM system which is connected to one BI system
Say BW1---CW1 system.
Now CW1 system transports are moved to CW2.
So CW2 system is connected to BW2 now.
So now i am in BW2 system and then i am going to replicate the datasources so while doing so do i need to select the only option RSDS only right?or else do i need to select any other option like 3.x or some thing else?
I am sure just we will replicate and we will select RSDS option only,because we did the same way in CW1-BW1 as well,later in BI we migrated and then we make them as bw3.x to bi7 datasources.

HI,
If your system is upgaded to BI7 then you need to do RSDS only.After replicating some times the data sources can become ianctive you can use the following program to reactivate them.
RSDS_DATASOURCE_ACTIVATE_ALL
Cheers,
Vikram

Similar Messages

  • PLEASE HELP ME TO FIND THE SOLUTION REGARDING "LOGICAL SYSTEM CHANGED"

    HAI EVERYBODY,
    PLEASE HELP ME TO FIND THE SOLUTION REGARDING "LOGICAL SYSTEM CHANGED" during the material master replication by using middleware parameters.
    step1 : i have taken SRM client 810 and named it as CHINNISRM
    step2 : i  have taken r3 client 810 and named it as CHINNIR3
    step3: During material master replication i maintained tables like crmconsum,crmrfcpar,crmparoltp in   r3   and smofparsfa in srm client and filtered the objects and loaded the objects through r3ac3,r3ac1,r3as.
    step4 : And later i have checked in r3 queues to activate the objects,but i have seen a message like  "LOGICAL SYSTEM CHANGED:SEE 588701".according to the oss instructions i have checked in CRMPRLS table in se16 in R3 .there i found out there is one logical client  named with T90CLNT810.
    oss :588701
    Solution
    There are different cases in which different forms of processing are
    required or where several options exist:
    - The logical system name of an R/3 Backend client was changed in
    current operation. In this case, the data hangs in the outbound
    queues of the R/3 Backend system as specified under point 1 of
    the symptom. In this case, the logical system name must be
    changed back to the original value. Then the outbound queues
    can be reactivated. If no data was transferred to the EBP/CRM
    server before the change, also a correctioin of the check table
    is possible.
    - The same logical system name was used again in a new client of
    an R/3 Backend system that was linked to the EBP/CRM server. In
    this case, the data is in the inbound queue of the EBP/CRM
    server with the exception GUID_FOR_LOGSYS_CHANGED. In this
    case, the queue entries which have status SYSFAIL must be rejected, however, not the entire queues. If the new client of  the R/3 Backend system you have linked has exactly the same
    data as the old client and if it is meant to replace the old
    client (that is, this was deactivated), also a correction of
    the check tables is possible. In this case, the inbound queues
    can be reactivated after the correction.
    oss:765018
    1. If the situation in your system corresponds to the situation described
    under "Reason and Prerequisites" and if symptom 1 occurs, you can
    delete the table entry from table CRMPRLS table (there is just one
    entry). Since there is no maintenance dialog for this table and you
    cannot maintain it using transaction SE16, you must use a report to
    delete it. This report is attached to this note as correction
    instructions.
    Create the report ZZ_DELETE_CRMPRLS in your system and copy the source
    code from the correction instructions. You cannot implement this
    source code using transaction SNOTE.
    You can use the report in every plug-in or plug-in basis system, even
    if it is not specified in the validity section.
    After you have run the report, you can trigger existing queues again
    in transaction SMQ1.
    2. If the situation in your system corresponds to the situation described
    under "Reason and prerequisite" and if symptom 2 occurs, you can
    delete the entry from table CRMMLSGUID (there is just one entry).
    Since there is no maintenance entry for this table and you cannot
    maintain it using transaction SE16, you must use a report to delete
    it. This report is attached to this note as correction instructions.
    If they do not yet exist, add the following messages to message class SMOF in your logon language:
    Message Message short text
    303 User &1 is not allowed to change table &2.
    304 User &1 IS not allowed to display table &2.
    305 Logical system &1 was not found in table &2.
    306 System error! The current client was not
    found in table T000.
    Create the report ZZ_DELETE_CRMMLSGUID in your system and copy the
    source code from the correction instructions. You cannot implement
    this source code using transaction SNOTE.
    You can use the report for every release of the CRM system, even if it
    is not specified in the validity section. The only exceptions are CRM
    releases with Support Package versions that are too low such as CRM
    Release 3.0 with Support Package 12.
    After you have run the report, you can trigger existing queues again
    in transaction SMQ1 of the R/3 back-end system or transaction SMQ2 of
    the CRM system.
    so what should i do to do the replication.please suggest me .untill and unless i solve my problem i cant move to the further activity.i hope you people can solve my problem.thanks in advance.
    thanks and best regards,
    n.chakradhar

    Hi chakradhar,
    Did you find a solution to your issue? We are facing a similar issue and looking to figure out how this can be resolved.
    BR// 420

  • Logical system changed

    HAI EVERYBODY,
    PLEASE HELP ME TO FIND THE SOLUTION REGARDING "LOGICAL SYSTEM CHANGED" during the material master replication by using middleware parameters.
    step1 : i have taken SRM client 810 and named it as CHINNISRM
    step2 : i have taken r3 client 810 and named it as CHINNIR3
    step3: During material master replication i maintained tables like crmconsum,crmrfcpar,crmparoltp in r3 and smofparsfa in srm client and filtered the objects and loaded the objects through r3ac3,r3ac1,r3as.
    step4 : And later i have checked in r3 queues to activate the objects,but i have seen a message like "LOGICAL SYSTEM CHANGED:SEE 588701".according to the oss instructions i have checked in CRMPRLS table in se16 in R3 .there i found out there is one logical client named with T90CLNT810.
    can anyone please give me the solution
    thanks and regards
    n,chakradhar

    Also u need to delete the entry with the old logical system name in TABLE CRMPRLS in MM.
    Check SAP Note # 765018

  • How to restore iTunes library after operating system changed?

    How to restore iTune library after operating system changed on the laptop? The syn is not working because it doesn't recognize the computer.

    Recovering your iTunes library from your iPod or iOS device: Apple Support Communities
    Syncing to a "New" Computer or replacing a "crashed" Hard Drive: Apple Support Communities
    Sync Your iOS Device with a New Computer Without Losing Data - How-To Geek

  • CO01 - system changes sch.start time given by the user (fwd sched., no cap. check, no shifts defined)

    Dear Experts,
    I am facing a very strange issue. Whenever I am trying to manually create and schedule a discrete production order  in ECC 6.0, with 1-forward scheduling (in CO01 transaction), by giving scheduled start date and time and pressing the "Schedule" button; the system changes the start time given by me (the date remains) and executes the scheduling with that start time.
    For example, when I want to produce 12072 PCs, and I give 08:00 as shceduled start time, the system changes it to 15:59, adds the operation times correctly and defines the 'correct' scheduled end date (again, with fwd scheduling type!).
    There is some logic on how the system changes the scheduled start time given by me. Below a certain production quantity, the issue doesn't come up, lead time scheduling is carried out, as it is expected. So the problem only occurs, when the order qty exceeds a certain limitation. In that case the order cannot be scheduled to a certain time phrame (between 07:59 and 15:59), so the system changes the scheduled start time given by me (whenever the order falls into the mentioned period). Depending on the order qty the mentioned period (to which the order cannot be scheduled) is changing.
    I made the following checks in the system:
    production calendar is set correctly, it is not blocking the production
    all the applied work centers are available from 00-24 hrs
    no shifts has been defined on any of the WCs, production is enabled in 00-24 hrs
    there is no other production scheduled on any of the work centers, capacity load is 0% on all of them, as it has been checked in CM03
    order scheduling was performed with '1-forward' scheduling type
    anyway, capacity check is switched off in the system
    formulas on the work centers are all correct, the processing time calculated based on them is also correct (No queue, wait, setup, etc. times are set in the system, we are only using processing times.)
    no error messages
    As far as I know, in the above case lead time scheduling must be carried out, the system is simply 'not allowed' to change the start date given by me, just add operation times to the start and define the scheduled end date.
    Thank you in advance,
    T

    Jiaul,
    please find the screenshots.
    1.Mark for Relevant finite scheduling in scheduling or capacity tab - yes
    2.Can be used for multiple operation - yes
    3.Capacity Planner Group set up - yes
    Caetano,
    in my case the order scheduled start date is exactly the same as the operation start date. The problem is that this date cannot be manually scheduled to a certain time interval, the system changes the scheduled start date specified by me. (Like there was a "blocked period".)
    Thank you,
    T

  • Eliminate entering password to make system changes

    How can I eliminate entering a password when an app whats to make system changes - seems redundant since I am the administrator

    I'm having a similar problem, since the 10.5.1 upgrade (I downloaded the 110MB version, as Apple readily admits that there are problems when using Software Update for upgrades).
    I ran Disk Utility to repair permissions on my boot drive, and it prompted me for my administrator password (something that I've only had to do since the upgrade to 10.5). This time, the user name was blank (usually it fills in the user name with the account name I'm logged in under). I entered the information, and got the error. Double checked everything, and still no luck. After a third attempt, I was told I had to wait a while before trying again.
    I'm hoping there's some simple fix or something I can easily to type in. I don't want to wait a few more weeks for Apple to release another patch, and I don't want to have to step back to an even more unstable version so I can use Disk Utility.
    ~Trilo~

  • Monitor system change status using Solman

    Is it possible to setup a CCMS monitor that causes an alert whenever the system change option is modified in SE06? Last week we had to open our production environment to make a change and then forgot to close it. The result was the system was left open for a few days before we realized the mistake.
    Any help is appreciated.
    I have found another way to monitor this scenario
    Edited by: Ed Mrowiec on Jul 13, 2010 9:05 AM

    Hi Rayyan,
    All of the readings regarding changing Oracle passwords state that they should be done in Brtools because it updates certain SAP tables with the new password information while doing it diterctly under SQLPLUS will only update Oracle
    All the SAP tables are owned by schema user and not system or SYS users. Both these users are used only by Oracle processes. Hence it has to be changed by SQL command.
    Hope this is useful.
    Regards,
    Deepak Kori

  • How to transport FM retraction configuration if source-system changes?

    Hi experts,
    I have configured FM retraction in ERP through SPRO connecting it to my Dev source system in my Dev ERP. What do I need to do to transport this configuration to my production ERP and make sure the BI source-system changes from Dev to Prod as well? Is there some kind of souce-system mapping as there is in the BI side for the extraction?
    For example, I have everything set-up for source-system BWD and I want it to change to BWP when I transport the configuration from ERP dev to ERP prod.
    Thanks
    Edited by: Pedro Fontes Pais on Dec 2, 2008 6:36 PM

    Hi Christian,
    Thanks for your reply, but I didn't get anywhere in OKE7 & OKE8 to include the credit records I made in KSAZ in a Transport.
    Can you elaborate it more.
    Thanks
    Amit Goyal

  • Device id of the root file system changes

    I have noticed that sometimes the device id of the root file system changes (it typically get incremented by one). This seems to happen after an abnormal shutdown. After a normal shutdown and reboot the device id reverts back to what it was previously.
    / is on a local disk (not NFS or anything like that) and I'm talking about the device id you can obtain via the following command:
    stat / | cut -d' ' -f1
    Any idea why this is happening?

    boot up a (any) live CD, cp -a, generate a new grub.cfg/adjust menu.lst and don't forget to update your fstab - done.
    Just done it myself.

  • System change in BW for enabling Formula editor

    I have a basis related question in BW.
    While trying to add the process type 'Decision between Multiple Alternatives' to my process chain in quality and production systems, I get a 'system not modifiable message' when I try to create a formula in the subsequent screen . I know this is because the systems are disabled against any customising and repository changes. Which setting(s) do I change to get this to work ?
    I tried changing SCC4 to allow repository changes and some settings in tcode RSWBO004 'System change option' but they had no effect. Any ideas as to what namespace setting I need to enable to allow the formula editor screen to be displayed ?
    I work in BW and was trying my hands at SCC4/system change etc hence am asking it in this forum. This is more of a BW relevant question rather than a generic basis question.

    Hi Daya,
       The object changeability option does not seem to help in this case. The formula builder or process type 'Decision between Multiple Alternatives' is not to be seen. FYI, the technical name for the formula builder is 'RSFO'. So there might be some setting around this.
    Thanks..

  • Master data in SRM when backend system change

    Hi SRM Gurus,
    Our scenario is ECC5 as backend system integrated with SRM 4.0(  SSP scenario and  iwith Catalog CCM2.0) Tech Implementation scenario is Extended classic .
    Now our backend system will be changed to ECC6 from ECC 5.
    ECC6 is installed on separate server for implementing changes in FI  ( separate Dev, QA, Prod environment )
    Question is that when we integrate SRM4.0 with ECC6, all master data (product categories, products & vendor master) needs to be replicated from ECC6 to SRM4.0
    As SRM system will remain same what will happen to present master data in Production system.
    As deletion is not suggested what is the correct approach.
    We can delete this master data in SRM Dev and QA.
    Can we keep master data pertaining to ECC5 as it is in SRM.
    Any idea as to what type of impacts one can expect if backend system changed from ECC5 to ECC6? Is there a recommended approach for this?
    I already referred note SAP note 418886 /995771.
    Regards,
    Avinash

    Hi
    By changing to ECC6.0 you would be entering a new backend system. Since the master data in SRM is linked to the respective backend system, it should not impact you.The old master data would still be there but linked to old backend system. You can let the data remain as it is if you want.
    Regards
    Sanjeev

  • Software components can keep modifiable in bw 3.5 system change options

    hello experts,
    can we keep software components modifiable in bw 3.5 production in system change option (se06)
    it very urgent

    Hi
    Transaction SE06 - Processing After Installation of the CTO
    Transaction SE06 has to be executed once in every newly installed R/3 System. This applies to an R/3 standard installation as well as the installation of a copy of an existing R/3 system.
    Transaction SE06 provides the following functions for processing after installation:
    Generating basic settings of the Change and Transport Organizer Closing other requests and tasks  Setting the system change option
    Meaning of the system name The system name (SID) is defined during the installation with R3setup and cannot be changed subsequently.
    When you choose names, make sure that there are no naming conflicts with existing systems. Under no circumstances may two systems within an SAP system group have the same name.
    The installation type of the R/3 System is specified in the initial screen:
    R/3 standard installation
    The R/3 System was installed from the SAP CD using R3setup. It is assumed that the system is running on a correct, delivered version of the R/3 System. No adjustments based on corrections or repairs have been made.
    If you set up an R/3 System that originated from a database copy using this option, problems could arise when you upgrade or modify objects with the Change and Transport Organizer.
    Database copy or database migration
    The R/3 System was created on the basis of a copy. R3setup provides utilities to do this. The R/3 System needs to be assigned a new and independent role within the SAP system group or outside of it.
    Before you connect the new R/3 System to the SAP system group, you have to give it a name that has not yet been used in the group.
    You should avoid using a previously used system name as this could cause serious complications and may also lead to the loss of information.
    If you have installed your SAP System as a copy of an existing SAP System then you must configure the CTS after installation.
    In SAP Systems installed with R3setup from the SAP CD the basic settings for the CTS are generated during the configuration of the  Transport Management System. You do not need to perform any processing after installation.
    Transaction SE06 provides the following functions for processing after installation:
    Generating basic settings of the Change and Transport System
    Setting the system change option
    Closing foreign requests and tasks
    You must specify the installation type of the SAP System on the initial screen:
    Standard installation
    The SAP System was installed from the SAP CD using R3setup. It is assumed that the SAP System is running as a correct, delivered version. No adjustments based on corrections or repairs have been made.
    If you set up an SAP System that originated from a database copy using this option, problems could arise when you upgrade the system or modify objects with the Transport Organizer.
    Database copy or database migration
    The SAP System was created on the basis of a copy. R3setup provides utilities to do this. The SAP System needs to be assigned a new and independent role within the SAP system group or outside of it.
    Before you connect the new SAP System to the SAP system group, you have to give it a name that has not yet been used in the group.
    Do not use an existing system name since this could cause serious conflicts and may lead to the loss of data.

  • SE03 / SE06 System Change Option Scope

    Hi All,
    We are creating a source system from R/3 to BW in some specify step we need to change the System Change Option of the sistem in a particular client (SE06 -> System Change Option -> No Modifiable to Modifiable and Modifiable to No Modifiable).
    My question is: This changes are Cross Client?
    Or only apply to the specify client where you are logged?
    Best Regards,
    Erick Ilarraza

    On their own, Global and Compenent specific change options are not client dependent as they are not related to the logical system of the ABAP user nor the master and transaction data (tables with field MANDT as key).
    Personally, I think of it as a "call stack" of checks on whether and what you can modify. Perhaps "System Change Update-ability" would have been a better label, but that is not good English.
    As the stack is released for a user in a client (a logical program system), the system determines what can be updated at different levels of the stack as it unfolds, a bit like a spring. At the top there is SE06. At the bottom of the spring there are individual authority-checks which are system, client, program flow and context, and user access dependent.
    Depending on where in the stack you release the spring from and how you got there, your user can update parts of the stack. Often the term "logical systems" is used in connection with the client (SCC4 client), but also many others such as workflow etc.
    => If the user can pass authority-checks for access at the bottom of the stack (S_DEVELOP is the key control here), then they can also change that which the top of the stack was designed to control. If you can debug, then there is nothing which will stand in your way.
    > My question is: This changes are Cross Client?
    It depends. You still need to control access via authorizations within the client to secure access to the whole system.
    Cheers,
    Julius

  • How to skip or edit scn (system change number) for brarchive

    hi experts,
    I have searched for procedures but didnt find any accurate solution. I wanted to skip the scn or the system change number for my brarchive. I have manually transported my files in the DR site because of seems to be FTP problems. I have to skip those redologs which i have already transfered. How am i suppose to do these? I'm looking forward to a textfile or control file wherein i could edit the number of the next redolog to process or sql commands or something?
    Thanks in advance.

    Still not sure what exactly your problem is.
    You transferred redologs; are they still available in their original oraarch location?
    If no : See my answer above. Did that many times myself.
    If yes : Log files will be copied by brarchive as always. Make sure that no harm will be done if they are overwritten at a place where they already exist, and where they maybe currently are processed by another program!
    regards

  • ERROR - no available datasource for source system exist

    I tried to load the master for 0Bill_Type
    1) Install infoobject business content and Create infoobject
    2) Activate datasource in R/3
    3) Replicate datasource
    4) Assign infosource ---> the error said no available datasource for source system exist
    When I go to source system--> Object overview --> I don't see anything at all?
    Please advise what went wrong ?

    Hi Pandadda,
    I think you have not transferred the APPLICATION COMPONENT HIERARCHY yet. If not, then do the following:
    1. In your R/3 system execute TCODE = SBIW.
    2. Go to BUSINESS CONTENT DATASOURCES
    3. Execute TRANSFER APPLICATION COMPONENT HIERARCHY by clicking the CLOCK.
    Replicate you datasource then check it on your BW system
    R,
    Adwin

Maybe you are looking for

  • Display exception in Adapter monitoring

    We have a requirement in which we need to convert a specific flat file structure into XML and then pass the message using XI. For this we have deployed an EJB module which is doing this conversion from flat file to XML. This EJB is being called from

  • Unable to connect to host on port 4241

    HI SAPers, I have started the gui, now that I am trying to connect to server I am getting the following error: Error while connecting to communication partner - see preceeding messages. Could not connect to host lxxxxxxx on port 4241. java.net.Connec

  • How to send a message to many and make it look like it was sent to one?

    Hi all! I have an email to send to guidance counselors at every high school in my state , and rather than sending the same email 60 times, I'd like to send one email, but make it look to the recipient as if it was sent only to them (so the other emai

  • Materials in GR blocked stock

    Hello, is there a straightforward way, to display all materials which are currently in GR blocked stock (received with movement type 103, but not yet 105)? Many thanks in advance. Regards, Sergei

  • Python and automator google docs upload

    Hi, i made a script to upload a selected document in finder to google docs. i wanted to make this into an automation because its easy, but it fails! when i choose the run script action i can only choose /usr/bin/python for the shell... but i installe