EDIFACT

Hi,
How to do the mapping in EDIFACT ?
Input is XML schema and output is EDIFACT schema. can u tell me the procedure for the mapping.
Vinoth

The BizTalk EDI Tutorials will get you started:
http://msdn.microsoft.com/en-us/biztalk/gg153503.aspx
http://msdn.microsoft.com/en-us/library/aa560270.aspx
The procedures are the same for EDIFACT and X12.

Similar Messages

  • File name structure for picking up X12/EDIFACT documents from an FTP Server

    According to some documents, and posts in this forum, the file name for a document retreived from an FTP server by B2B has to be in the following format: %TPName%_%X12 Doc Type%_%X12 Version_1_12345.dat
    Why is this format required? Is it possible to obtain all this information for the Header Envelopes of each X12 or even EDIFACT EDI Document?

    Thanks Ramesh.
    I did specify the propery oracle.tip.adapter.b2b.edi.identifyFromTP=Group, but I was still not getting the expected results. Now I played around for a while and now I identified the problem . When I specify the property oracle.tip.adapter.b2b.edi.identifyFromTP=Group, I should use the Group ID when I create the agreement so that the agreement would be identified by using group id. I think I got that working now.
    I have one question on the trading partner end point URL in FILE/FTP. When I specify the endpoint URL for a trading partner would that be used to pull the document from the trading partner or push the documents to trading partner?
    In my testing even though I specified the end point URL for the trading partner using FILE protocol, when I put the message in that URL ( folder), it did not pull the message from that URL ( this trading partner is the initiator for that EDI 204 message). But when I put the messages into the host partner's end point URL, it got pulled and processed successfully. I am little confused on the usage of trading partner end point URL for the FILE/FTP protocols . Could you explain me little bit or point me to a documnet where it is expalined in detail?
    Bala

  • Open PI :  how to trigger EDIFACT adaptor

    Hi all,
    we imported open source EDIFACT adaptor to our PI 7.1 EHP1  system. Adaptor seems running.
    i imported EANCOM_2002.xsd  as external definition, create my outbound Service Interface and create my sender Communication channel with EDIFACT adaptor.
    I cant trigger adaptor, i tried below url  but nothing happened, in communication channel nothing happen.
    Is there any idea to use EDIFACT adaptor? i want to try a simple example.
    thanks.
    url;
    http://xxxx.xxxx.com:50900/EdifactHttpAdapter/servlet/EdifactAdapterFacade?FS=CC_BC_EDIFACT_EDIFACT_SND&TS=BS500DEV&IF=SI_EANCOM_2002_OUT&NS=http://xxxxx.com/EDIFACT
    also tried this in html file;
    <FORM action="http://xxxx.xxxx.com:50900/EdifactHttpAdapter/servlet/EdifactAdapterFacade?FS=CC_BC_EDIFACT_EDIFACT_SND&TS=BS500DEV&IF=SI_EANCOM_2002_OUT&NS=http://xxxxx.com/EDIFACT" method="post">
       <P>
       <TEXTAREA name="thetext" rows="20" cols="80">  
    UNBUNOA:2111222333:1222333444:1060705:154512345'UNH1ORDERS:D:01B:UN:EAN010'BGM220::91009239'DTM137:20060705:102'DTM2:20060705:102'NADBY5400152201228::9'NADSU5410256000099::9'NADDP5400152201228::9'CUX2:EUR:9'LIN1+5410256410013:SRV'PIA1388:SA::91'QTY21:10'PRIAAA:15.99::LIU'UNSS'UNT141'UNZ112345'
       </TEXTAREA>
       <INPUT type="submit" value="Send"><INPUT type="reset">
       </P>
    </FORM>

    without AS2 protocol
    If you don't want AS2 protocol, why do you need AS2 connector? If the requirement is only changing EDIFACT to and XML message, you don't need an entire Adapter. Just an adapter module will also be enough. If you want a free module, you may use Open PI Conversion Module in your regular adapters e.g. file adapter.
    Regards,
    Prateek Raj Srivastava

  • B2B in PI 7.0 - EDIFACT format to IDOC and vice versa

    We need to establish B2B scenario in PI 7.0
    IDOC to EDIFACT and EDIFACT to IDOC.
    Please let me know the solution without using any third party adapter like seeburger.
    Any example scenario of the same case will be helpful

    Hi ,
    If you are decided to not using SeeBurger then its difficult to implement B2B Scenario
    Your requirement IDOC 2 EDIFACT or Vice VERSA, you have to do more analyzation about EDIFACT.
    You can acheive using Adapter module, you have to about EJB's stuff to write Adapter module to support EDIFACT Message, Search for info about Adapter Module in SDN you wil find some lot off stuff about Adapter MODULE.
    then coming to mapping its really challenging to do Mapping between IDOC TO EDIFACT.
    You have to alalyze the EDIFACT Structure .
    I implemented B2B scebario in my project SeeBurger.
    Regards,
    Raj

  • Mapping Problem ORDERS Idoc to Edifact

    Hi,
    I have a mapping problem with the IDOC ORDERS:
    I get the IDOC with several E1EDP01. Each E1EDP01 has several E1EDPT1, where i want only the first one (which I get over the TDID value). Each E1EDPT1 has min. 1 E1EDPT2.
    Now I have to map each field TDLINE from first two E1EDPT2 of the first E1EDPT1 to the Edifact fields /LIST/S_UNB/S_UNH/G_SSG25/S_LIN/S_IMD[1]/C_C273/D_7008 (from the first E1EDPT2) and, if a second E1EDPT2 exists in /LIST/S_UNB/S_UNH/G_SSG25/S_LIN/S_IMD[1]/C_C273/D_7008_2.
    I use following UDF:
    //a = TDLINE
    //b = Number of entry in the List
    int pos =Integer.parseInt(b[0]);
    if ( pos < a.length )
    result.addValue(a[pos]);
    else
    result.addValue(ResultList.SUPPRESS);
    Unfortunatly, I think becaus of the context problems (not every E1EDPT1 has two E1EDPT2), it's not working. Could somebody help me with this problem?
    Thanks in advance
    Dominic

    Dear Dominic ,
    I had same problem when I was trying to do the same thing for FTX segment.
    Your UDF is fine but you don't need else condition.
    //a = TDLINE
    //b = Number of entry in the List
    int pos =Integer.parseInt(b[0]);
    if ( pos < a.length )
    result.addValue(a[pos]);
    for C_C273 assigned contant value and
    D_7008 assigned TDLINE but change the context to E1EDPT1
    and for D_7008_2
    TDLINE(context to E1EDPT1 )
                                                      ====>UDF====>D_7008_2
    Contant(=1)
    It should work becasue my map is working fine. If not let me know error message.
    Thanks
    Shubhankar

  • DESADV01 E1EDP07 segment per line item causes EDIFACT error

    When a Sales Order has the PO Number + Date populated, the subsequent outbound Delivery IDoc (DESADV01) contains a parent E1EDP07 segment for every child line item segment (E1EDP09).  For a SO without PO Date, the IDoc is created with a single E1EDP07 with multiple child E1EDP09 segments.  This is standard SAP - do you need to code around this?
    The first scenario causes an error in EDIFACT mapping, as a limit of 9 RFF segments is allowed (E1EDP07 is a level 1 segment).  Partner systems reject this.

    Hi,
    Segment field should be optional, so check the posting keys in OB41, check the GL account which hit this posting and check the FIeld status in OBC4 and make the segment field as optional.
    while posting the transactions you can check in more then Profit center and segment details will be updated in the postings.
    try out, this might help. check the new ledger document types also.
    Regards,
    Padma

  • Using B2B for sending PAYMUL files in EDIFACT format

    Hi B2B Gurus,
    One of our client has the following requirement.
    1) Create Payment batches in Oracle AP and Format the payments using an EDI format program.
    2) Translate the EDI format file into PAYMUL EDIFACT format.
    3) Send the PAYMUL file across to the bank and receive the acknowledgments.
    At the moment our client uses the services of a third party vendor to take care of the EDI translation, document management and transportation
    features.
    Would it be possible to achieve the above requirement using Oracle B2B Integration + Adapters?
    If yes, would request you to provide me with the Adapters we need to buy (license required) and also the components that would be required to achieve the above functionality.
    Thanks and Regards,
    B2B Naive
    Edited by: user5546779 on Feb 9, 2010 11:05 PM

    Hi,
    Oracle B2B can translate the EDI XML to native EDI format and vice-versa. It has support for both the flavours of EDI - EDIFACT and X12. It has the support for almost all the transport protocols as well. Moreover, for any customization, there is facility of java callouts as well.
    Would it be possible to achieve the above requirement using Oracle B2B Integration + Adapters?From the high level requirement you posted, I can say that it is very much possible to achieve this using Oracle Integration B2B product only.
    If yes, would request you to provide me with the Adapters we need to buy (license required) and also the components that would be required to achieve the above functionality.Now this will vary as per your network design, solution design and detailed requirements but at high level you need to buy only Oracle B2B. First of all you should decide the scope and requirements and then go for estimation. After that decide whether you may go with 10g version or you need 11g (as it has various supports which are not there in 10g).
    For the start, below documents may help you out -
    http://www.oracle.com/technology/products/integration/b2b/pdf/edi_cookbook_oracle_b2b.pdf
    http://www.oracle.com/technology/products/integration/b2b/pdf/B2B_TN_002_B2B_Standards_Supported.pdf
    http://www.oracle.com/technology/products/integration/b2b/pdf/B2B_TN_014_Questionaire_Sizing.pdf
    http://www.oracle.com/technology/products/integration/b2b/pdf/B2B_TN_015_Questionaire_SI_Assessement.pdf
    http://www.oracle.com/technology/products/integration/b2b/pdf/B2B_TN_016_Questionaire_Trading_Partner.pdf
    http://www.oracle.com/technology/products/soa/b2b/collateral/b2b_11g_ds.pdf
    http://www.oracle.com/technology/products/integration/b2b/Oracle_B2B_10g.html
    Regards,
    Anuj

  • Trading Partner Agreement Not found error in EDI EDIFACT Scenario

    Hello all,
    I am getting the following error in the trace file in the EDI EDIFACT over Generic Exchange Scenario,i have verified the agreement effective to date,i also have checked the enq_orders.properties & enq_ordrsp.properties on both the servers and the FromParty Name and ToParty Name are shown correctly.so where does the actual problem occur can anyone plz help me out to solve this issue.
    MsgID = C0A8010111EF3AC936E0000068CB7800
    ReplyToMsgID = null
    FromParty = Acme
    ToParty = Acme
    EventName = Exception
    DoctypeName = Exception
    DoctypeRevision = 1.0
    MsgType = 3
    payload length = 1820
    *&lt;Exception xmlns="http://integration.oracle.com/B2B/Exception" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"&gt;*
    *&lt;correlationId&gt;null&lt;/correlationId&gt;*
    *&lt;b2bMessageId&gt;C0A8010111EF3AC936E0000068CB7800&lt;/b2bMessageId&gt;*
    *&lt;errorCode&gt;AIP-50547&lt;/errorCode&gt;*
    *&lt;errorText&gt;Trading partner agreement not found for the given input values: From partyNAME "Acme", To partyNAME "Acme", Business action name "Process_ORDERS"; also verify agreement effectiveToDate&lt;/errorText&gt;*
    *&lt;errorDescription&gt;*
    *&lt;![CDATA[Machine Info: (mcity94)*
    *Description: Unable to identify the trading partner agreement from the given input values. Also verify agreement effectiveToDate*
    *StackTrace:*
    *Error -:  AIP-50547:  Trading partner agreement not found for the given input values: From party[NAME|http://forums.oracle.com/forums/] "Acme", To partyNAME "Acme", Business action name "Process_ORDERS"; also verify agreement effectiveToDate*
    **     at oracle.tip.adapter.b2b.tpa.RepoDataAccessor.getAgreementNameByBaTPName(RepoDataAccessor.java:2225)**
    **     at oracle.tip.adapter.b2b.tpa.TPAIdentifier.identifyTPA(TPAIdentifier.java:181)**
    **     at oracle.tip.adapter.b2b.tpa.TPAProcessor.processTPA(TPAProcessor.java:511)**
    **     at oracle.tip.adapter.b2b.tpa.TPAProcessor.processIncomingTPA(TPAProcessor.java:229)**
    **     at oracle.tip.adapter.b2b.engine.Engine.processIncomingMessage(Engine.java:1715)**
    **     at oracle.tip.adapter.b2b.engine.Engine.incomingContinueProcess(Engine.java:2404)**
    **     at oracle.tip.adapter.b2b.engine.Engine.handleMessageEvent(Engine.java:2303)**
    **     at oracle.tip.adapter.b2b.engine.Engine.processEvents(Engine.java:2258)**
    **     at oracle.tip.adapter.b2b.data.MsgListener.onMessage(MsgListener.java:500)**
    **     at oracle.tip.adapter.b2b.data.MsgListener.run(MsgListener.java:348)**
    **     at java.lang.Thread.run(Thread.java:534)**
    *]]&gt;*
    *&lt;/errorDescription&gt;*
    *&lt;errorSeverity&gt;2&lt;/errorSeverity&gt;*
    *&lt;/Exception&gt;*
    Thanx
    Sunny
    Edited by: sunny kay on Jan 20, 2009 7:45 AM

    Hi
    Since the error states "Process_ORDERS" as the Business action I assume you are trying to enq the ORDERS document from Acme to GlobalChips. The issue then would be due to the fact that there is a trailing space character after the GlobalChips
    Please check for a space (or spaces) after
    to = GlobalChips
    Also ensure that the UI has the trading partner with the same spelling ie. GlobalChips and not Globalchips
    Thanks,
    --Arun                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       

  • How to PI and UN/EDIFACT scenarios?

    Hi folks,
    I’ll start soon a new PI project with EDI scenarios. It will be my first XI-EDI project and I don’t have any experience with this kind of scenarios. I already read some documentation, as well as some info at SDN, but I still have some inconsistencies:
    How to start? Which is the sequence of steps to configure such scenarios?
    Do I need Conversion Agent?
    Can I use any adapter of AE or I am limited to B2B adapters?
    We are going to work with UN/EDIFACT protocol for a network gas - http://www.edigas.org/ if anyone has experience or did some similar scenarios that could guide me I would appreciate very much.
    Thanks in advance and regards,
    Ricardo.

    Hi,
    this might be helpful:
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/6dc02f5d-0601-0010-cd9d-f4ff9a7e8c33
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/135b0b94-0701-0010-f6a9-86a14057544a
    Regards
    Patrick

  • Mapping iDoc to EDIFACT: Segment Count

    Hi experts,
    I am mapping a DELVRY05 iDoc to an EDIFACT DESADV document. Everythings fine so far, but I'm encountering troubles with filling the EDIFACT UNT Segment with the number of segments in the generated message.
    I am using the OPI2 conversion module and so I get a nice xml structure for the EDIFACT message. Is there a way to count created xml nodes? I think this would solve my issue.
    Thanks for your answers!

    That is an example for the source idoc
    <?xml version="1.0" encoding="UTF-8"?>
    <DELVRY05>
       <IDOC BEGIN="1">
          <EDI_DC40 SEGMENT="1">
             <TABNAM>EDI_DC40</TABNAM>
             <MANDT>100</MANDT>
             <DOCNUM>0000000002603007</DOCNUM>
             <DOCREL>700</DOCREL>
             <STATUS>30</STATUS>
             <DIRECT>1</DIRECT>
             <OUTMOD>2</OUTMOD>
             <IDOCTYP>DELVRY05</IDOCTYP>
             <MESTYP>DESADV</MESTYP>
             <SNDPOR>SAPKTS</SNDPOR>
             <SNDPRT>LS</SNDPRT>
             <SNDPRN>KTS100</SNDPRN>
             <RCVPOR>A000000016</RCVPOR>
             <RCVPRT>KU</RCVPRT>
             <RCVPFC>WE</RCVPFC>
             <RCVPRN>0004088156</RCVPRN>
             <CREDAT>20101123</CREDAT>
             <CRETIM>115322</CRETIM>
             <SERIAL>20101123115321</SERIAL>
          </EDI_DC40>
          <E1EDL20 SEGMENT="1">
             <VBELN>0080775647</VBELN>
             <VSTEL>0132</VSTEL>
             <VKORG>0130</VKORG>
             <LGNUM>132</LGNUM>
             <INCO1>EXW</INCO1>
             <INCO2>Leonding</INCO2>
             <ROUTE>009999</ROUTE>
             <VSBED>25</VSBED>
             <BTGEW>0.500</BTGEW>
             <NTGEW>0.500</NTGEW>
             <GEWEI>KGM</GEWEI>
             <VOLUM>0.000</VOLUM>
             <ANZPK>00000</ANZPK>
             <PODAT>20101123</PODAT>
             <POTIM>115321</POTIM>
             <E1EDL22 SEGMENT="1">
                <VSTEL_BEZ>Neuson Ersatzt.Linz II</VSTEL_BEZ>
                <VKORG_BEZ>Neuson Linz</VKORG_BEZ>
                <LGNUM_BEZ>LVS Neuson Linz Ersat. II</LGNUM_BEZ>
                <INCO1_BEZ>Ab Werk</INCO1_BEZ>
                <ROUTE_BEZ>NK Linz</ROUTE_BEZ>
                <VSBED_BEZ>Spedition</VSBED_BEZ>
             </E1EDL22>
             <E1EDL21 SEGMENT="1">
                <LFART>LF</LFART>
                <EXPKZ>X</EXPKZ>
                <LIFSK>10</LIFSK>
                <LPRIO>00</LPRIO>
                <KDGRP>02</KDGRP>
                <TRAGR>0100</TRAGR>
                <TRSPG>03</TRSPG>
                <E1EDL23 SEGMENT="1">
                   <LFART_BEZ>Auslieferung</LFART_BEZ>
                   <LIFSK_BEZ>zu verpacken</LIFSK_BEZ>
                   <KDGRP_BEZ>Handel</KDGRP_BEZ>
                   <TRAGR_BEZ>Transportgr. NK</TRAGR_BEZ>
                </E1EDL23>
             </E1EDL21>
             <E1EDL18 SEGMENT="1">
                <QUALF>ORI</QUALF>
             </E1EDL18>
             <E1ADRM1 SEGMENT="1">
                <PARTNER_Q>AG</PARTNER_Q>
                <PARTNER_ID>0004088156</PARTNER_ID>
                <LANGUAGE>EN</LANGUAGE>
                <FORMOFADDR>Firma</FORMOFADDR>
                <NAME1>Caterpillar Ltd.</NAME1>
                <STREET1>Peckleton Lane</STREET1>
                <POSTL_COD1>LE9 9JT</POSTL_COD1>
                <CITY1>Leicester</CITY1>
                <TELEPHONE1>14558258-00</TELEPHONE1>
                <COUNTRY1>GB</COUNTRY1>
             </E1ADRM1>
             <E1ADRM1 SEGMENT="1">
                <PARTNER_Q>SP</PARTNER_Q>
                <PARTNER_ID>0006006873</PARTNER_ID>
                <LANGUAGE>DE</LANGUAGE>
                <NAME1>DHL Express</NAME1>
                <STREET1>BleibtreustraÃu0178e 2</STREET1>
                <POSTL_COD1>1110</POSTL_COD1>
                <CITY1>Wien</CITY1>
                <TELEPHONE1>1 76600-3286</TELEPHONE1>
                <TELEFAX>1 76600-3475</TELEFAX>
                <COUNTRY1>AT</COUNTRY1>
                <REGION>W</REGION>
             </E1ADRM1>
             <E1ADRM1 SEGMENT="1">
                <PARTNER_Q>WE</PARTNER_Q>
                <PARTNER_ID>0004088156</PARTNER_ID>
                <LANGUAGE>EN</LANGUAGE>
                <FORMOFADDR>Firma</FORMOFADDR>
                <NAME1>Caterpillar Ltd.</NAME1>
                <STREET1>Peckleton Lane</STREET1>
                <POSTL_COD1>LE9 9JT</POSTL_COD1>
                <CITY1>Leicester</CITY1>
                <TELEPHONE1>14558258-00</TELEPHONE1>
                <COUNTRY1>GB</COUNTRY1>
             </E1ADRM1>
             <E1ADRM1 SEGMENT="1">
                <PARTNER_Q>OSP</PARTNER_Q>
                <PARTNER_ID>0132</PARTNER_ID>
                <LANGUAGE>DE</LANGUAGE>
                <NAME1>Neuson Ersatzt. Linz II</NAME1>
                <COUNTRY1>AT</COUNTRY1>
             </E1ADRM1>
             <E1ADRM1 SEGMENT="1">
                <PARTNER_Q>OSO</PARTNER_Q>
                <PARTNER_ID>0130</PARTNER_ID>
                <LANGUAGE>DE</LANGUAGE>
                <COUNTRY1>AT</COUNTRY1>
             </E1ADRM1>
             <E1EDT13 SEGMENT="1">
                <QUALF>006</QUALF>
                <NTANF>20101123</NTANF>
                <NTANZ>000000</NTANZ>
                <NTEND>20101123</NTEND>
                <NTENZ>000000</NTENZ>
                <ISDD>00000000</ISDD>
                <ISDZ>000000</ISDZ>
                <IEDD>00000000</IEDD>
                <IEDZ>000000</IEDZ>
             </E1EDT13>
             <E1EDT13 SEGMENT="1">
                <QUALF>003</QUALF>
                <NTANF>20101123</NTANF>
                <NTANZ>000000</NTANZ>
                <NTEND>20101123</NTEND>
                <NTENZ>000000</NTENZ>
                <ISDD>00000000</ISDD>
                <ISDZ>000000</ISDZ>
                <IEDD>00000000</IEDD>
                <IEDZ>000000</IEDZ>
             </E1EDT13>
             <E1EDT13 SEGMENT="1">
                <QUALF>001</QUALF>
                <NTANF>20101123</NTANF>
                <NTANZ>000000</NTANZ>
                <NTEND>20101123</NTEND>
                <NTENZ>000000</NTENZ>
                <ISDD>00000000</ISDD>
                <ISDZ>000000</ISDZ>
                <IEDD>00000000</IEDD>
                <IEDZ>000000</IEDZ>
             </E1EDT13>
             <E1EDT13 SEGMENT="1">
                <QUALF>007</QUALF>
                <NTANF>20101123</NTANF>
                <NTANZ>000000</NTANZ>
                <NTEND>20101123</NTEND>
                <NTENZ>000000</NTENZ>
                <ISDD>00000000</ISDD>
                <ISDZ>000000</ISDZ>
                <IEDD>00000000</IEDD>
                <IEDZ>000000</IEDZ>
             </E1EDT13>
             <E1EDT13 SEGMENT="1">
                <QUALF>010</QUALF>
                <NTANF>20101123</NTANF>
                <NTANZ>000000</NTANZ>
                <NTEND>20101123</NTEND>
                <NTENZ>000000</NTENZ>
                <ISDD>00000000</ISDD>
                <ISDZ>000000</ISDZ>
                <IEDD>00000000</IEDD>
                <IEDZ>000000</IEDZ>
             </E1EDT13>
             <E1EDT13 SEGMENT="1">
                <QUALF>015</QUALF>
                <NTANF>20101123</NTANF>
                <NTANZ>000000</NTANZ>
                <NTEND>20101123</NTEND>
                <NTENZ>000000</NTENZ>
                <ISDD>00000000</ISDD>
                <ISDZ>000000</ISDZ>
                <IEDD>00000000</IEDD>
                <IEDZ>000000</IEDZ>
             </E1EDT13>
             <E1EDL33 SEGMENT="1">
                <ALAND>AT</ALAND>
                <EXPVZ>3</EXPVZ>
                <IEVER>3</IEVER>
                <E1EDL34 SEGMENT="1">
                   <EXPVZ_BEZ>StraÃu0178enverkehr</EXPVZ_BEZ>
                   <IEVER_BEZ>StraÃu0178enverkehr</IEVER_BEZ>
                </E1EDL34>
             </E1EDL33>
             <E1EDL28 SEGMENT="1">
                <ROUTE>009999</ROUTE>
                <ROUID>NK LINZ</ROUID>
                <DISTZ>0.000</DISTZ>
                <E1EDL29 SEGMENT="1">
                   <ROUTE_BEZ>NK Linz</ROUTE_BEZ>
                </E1EDL29>
             </E1EDL28>
             <E1EDL24 SEGMENT="1">
                <POSNR>000010</POSNR>
                <MATNR>000000001000248477</MATNR>
                <MATWA>000000001000003928</MATWA>
                <ARKTX>PNEUMATIC SPRING</ARKTX>
                <ORKTX>Gasfeder 350N/L185/Hub64</ORKTX>
                <SUGRD>0001</SUGRD>
                <MATKL>000040900</MATKL>
                <WERKS>0131</WERKS>
                <LGORT>E002</LGORT>
                <LFIMG>1.000</LFIMG>
                <VRKME>ST</VRKME>
                <LGMNG>1.000</LGMNG>
                <MEINS>ST</MEINS>
                <NTGEW>0.500</NTGEW>
                <BRGEW>0.500</BRGEW>
                <GEWEI>KGM</GEWEI>
                <VOLUM>0.000</VOLUM>
                <LADGR>0131</LADGR>
                <TRAGR>0100</TRAGR>
                <VKBUR>0131</VKBUR>
                <VTWEG>02</VTWEG>
                <SPART>01</SPART>
                <GRKOR>000</GRKOR>
                <POSEX>000000</POSEX>
                <VFDAT>00000000</VFDAT>
                <EXPIRY_DATE_EXT>0</EXPIRY_DATE_EXT>
                <VGBEL>0001416863</VGBEL>
                <VGPOS>000020</VGPOS>
                <ORMNG>         1.000</ORMNG>
                <EXPIRY_DATE_EXT_B>0</EXPIRY_DATE_EXT_B>
                <E1EDL25 SEGMENT="1">
                   <LGORT_BEZ>Ersatzteill. 02</LGORT_BEZ>
                   <LADGR_BEZ>Neuson Ersatzteile</LADGR_BEZ>
                   <TRAGR_BEZ>Transportgr. NK</TRAGR_BEZ>
                   <VKBUR_BEZ>Neuson Ersatzteile</VKBUR_BEZ>
                   <VTWEG_BEZ>NK Ersatzteile</VTWEG_BEZ>
                   <SPART_BEZ>Produktsparte 01</SPART_BEZ>
                </E1EDL25>
                <E1EDL26 SEGMENT="1">
                   <PSTYV>ZERS</PSTYV>
                   <MATKL>000040900</MATKL>
                   <PRODH>409</PRODH>
                   <UMVKZ>1</UMVKZ>
                   <UMVKN>1</UMVKN>
                   <UEBTO>0.0</UEBTO>
                   <UNTTO>0.0</UNTTO>
                   <E1EDL27 SEGMENT="1">
                      <PSTYV_BEZ>Normalpos Ersatzteil</PSTYV_BEZ>
                      <MATKL_BEZ>Gasfeder</MATKL_BEZ>
                      <PRODH_BEZ>Gasfeder</PRODH_BEZ>
                      <WERKS_BEZ>Wacker Neuson Linz GmbH ET</WERKS_BEZ>
                   </E1EDL27>
                </E1EDL26>
                <E1EDL35 SEGMENT="1">
                   <STAWN>83024900</STAWN>
                   <EXPRF>10000</EXPRF>
                   <EXART>1</EXART>
                   <HERKL>FR</HERKL>
                   <GRWRT>          0.00</GRWRT>
                   <E1EDL36 SEGMENT="1">
                      <STXT1>Beschläge und ähnliche Waren, aus</STXT1>
                      <STXT2>unedlen Metallen, für anderweit nicht</STXT2>
                      <STXT3>genannte Zwecke (ausg. Scharniere, Lauf-</STXT3>
                      <STXT4>rädchen oder -rollen und Baubeschläge)</STXT4>
                      <EXPRF_BEZ>Ausfuhr o. voran. zollr. Best.</EXPRF_BEZ>
                      <EXART_BEZ>Kauf/Verkauf</EXART_BEZ>
                      <HERKL_BEZ>Frankreich</HERKL_BEZ>
                   </E1EDL36>
                </E1EDL35>
                <E1EDL43 SEGMENT="1">
                   <QUALF>C</QUALF>
                   <BELNR>0001416863</BELNR>
                   <POSNR>000020</POSNR>
                   <DATUM>20101123</DATUM>
                </E1EDL43>
                <E1EDL41 SEGMENT="1">
                   <QUALI>001</QUALI>
                   <BSTNR>TEST FAH</BSTNR>
                   <BSTDT>20101123</BSTDT>
                </E1EDL41>
             </E1EDL24>
          </E1EDL20>
       </IDOC>
    </DELVRY05>
    and thats what for the moment is the output for the EDIFACT before OPI2 conversion module. UNT segment count is hardcoded set to 1.
    <?xml version="1.0" encoding="UTF-8"?>
    <ns0:EDIFACTMessage xmlns:ns0="http://cbsgmbh.com/xi/EDIFACT/99A">
       <Header>
          <SenderID>Test_SenderSystem</SenderID>
          <ReceiverID>Test_ReceiverSystem</ReceiverID>
          <MessageType>EDIFACTMessage</MessageType>
       </Header>
       <ListOfDespatchAdvises>
          <DespatchAdvise>
             <HEADING>
                <UNH>
                   <UNH01>0000000002603007</UNH01>
                   <UNH02>
                      <S00901>DESADV</S00901>
                      <S00902>D</S00902>
                      <S00903>98B</S00903>
                      <S00904>UN</S00904>
                   </UNH02>
                </UNH>
                <BGM>
                   <BGM01>
                      <C00201>351</C00201>
                   </BGM01>
                   <BGM02>
                      <C10601>0000000002603007</C10601>
                   </BGM02>
                   <BGM03>9</BGM03>
                </BGM>
                <DTM>
                   <DTM01>
                      <C50701>11</C50701>
                      <C50702>00201011230000</C50702>
                   </DTM01>
                </DTM>
                <DTM>
                   <DTM01>
                      <C50701>132</C50701>
                      <C50702>00201011230000</C50702>
                   </DTM01>
                </DTM>
                <DTM>
                   <DTM01>
                      <C50701>137</C50701>
                      <C50702>00201011230000</C50702>
                   </DTM01>
                </DTM>
                <MEA>
                   <MEA01>PD</MEA01>
                   <MEA02>
                      <C50201>G</C50201>
                   </MEA02>
                   <MEA03>
                      <C17401>KGM</C17401>
                      <C17402>0.500</C17402>
                   </MEA03>
                </MEA>
                <MEA>
                   <MEA01>PD</MEA01>
                   <MEA02>
                      <C50201>N</C50201>
                   </MEA02>
                   <MEA03>
                      <C17401>KGM</C17401>
                      <C17402>0.500</C17402>
                   </MEA03>
                </MEA>
                <MEA>
                   <MEA01>PD</MEA01>
                   <MEA02>
                      <C50201>WT</C50201>
                   </MEA02>
                   <MEA03>
                      <C17401>KGM</C17401>
                      <C17402>0.500</C17402>
                   </MEA03>
                </MEA>
             </HEADING>
             <DETAIL>
                <CPS>
                   <CPS01>1</CPS01>
                   <CPS03>3</CPS03>
                </CPS>
                <SG16>
                   <LIN>
                      <LIN02>000010</LIN02>
                   </LIN>
                   <PIA>
                      <PIA01>1</PIA01>
                      <PIA02>
                         <C21201>0001416863</C21201>
                         <C21202>PO</C21202>
                      </PIA02>
                   </PIA>
                   <PIA>
                      <PIA01>1</PIA01>
                      <PIA02>
                         <C21201>000020</C21201>
                         <C21202>PL</C21202>
                      </PIA02>
                   </PIA>
                   <PIA>
                      <PIA01>1</PIA01>
                      <PIA02>
                         <C21201>TEST FAH</C21201>
                         <C21202>ON</C21202>
                      </PIA02>
                   </PIA>
                </SG16>
             </DETAIL>
             <SUMMARY>
                <UNT>
                   <UNT01>1</UNT01>
                   <UNT02>0000000002603007</UNT02>
                </UNT>
             </SUMMARY>
          </DespatchAdvise>
       </ListOfDespatchAdvises>
    </ns0:EDIFACTMessage>

  • EDIFACT File TO IDOC Archive directory file name.

    HI Experts,
    I have EDIFACT file to IODC scenario. I have  multiple source file locaiton but only one Archive location directory.But I have three different kind of file coming form three different location.
    we can only have one archive directory per service, is it possible to manipulate the file name so we can tell if files were successful or failed?
    For example, FileName1.txt, if it was successful, it would move to the archive directory and rename to u201CFileName1.txt.PASSu201D,
    if it failed it would move to archive directory like u201CFileName1.txt.FAILu201D. Is this functionality possible?
    Or will we just have to rely on Alert Categories to tell us when files have failed?
    Kindly give your valuable suggestion.
    Regards,
    Sumit Gupta

    >
    sumit gupta wrote:
    > HI Experts,
    >
    > I have EDIFACT file to IODC scenario. I have  multiple source file locaiton but only one Archive location directory.But I have three different kind of file coming form three different location.
    >
    > we can only have one archive directory per service, is it possible to manipulate the file name so we can tell if files were successful or failed?
    > For example, FileName1.txt, if it was successful, it would move to the archive directory and rename to u201CFileName1.txt.PASSu201D,
    > if it failed it would move to archive directory like u201CFileName1.txt.FAILu201D. Is this functionality possible?
    > Or will we just have to rely on Alert Categories to tell us when files have failed?
    >
    > Kindly give your valuable suggestion.
    >
    > Regards,
    > Sumit Gupta
    When you say success or failure does it mean a successful IDoc created in SAP? if so you will have to use a BPM and on successful creation fo the IDoc write the file out with the PASS name else FAIL name.
    you can also look at employing  scripts but there is no standard feature for this requirement. I gather alert is a better option.

  • Handling EDIFACT Files in File adapter without going for Seeburger adapters

    Hi Guys,
    Is it possible to convert the EDIFACT files into XML using File content conversion?
    We got some requirement where we need to exchange EDIFACT files like DESADV and ORDERS with our partner. I know we can handle these EDI formats using Seeburger adapters like BIC,AS2.
    I'm just wondering is it possible to handle these files using FCC in File adapter or Is it recommended to go for Seeburger?
    Thanks
    Deepthi

    Hi,
    its better to opt for seeburger for EDI data processings..
    http://www.sdn.sap.com/irj/scn/index?rid=/library/uuid/20ed5d5b-b188-2c10-76a2-997a616e48a9
    http://www.cbs-consulting.com/EN/Services/ProcessesApplications/SAP__TechnologyConsulting/OpenPI/OpenPI__n,naviExpand=.html__nnn=true
    Check the above links can be helpful..
    HTH
    Rajesh

  • Converting INVOIC02 idoc to EDIFACT INVOIC message (Using Adapter Module

    Hi Friends,
    We are sending customer idoc (INVOIC02) from R/3 to external system through PI. We want to generate EDIFACT output file (message type : INVOIC).
    Is it possible to convert IDoc message to EDI file format through java adapter module ? Will adapter module support this  without using Seeburger adapter ?
    kindly clarify, friends.
    Kind regards,
    Jegathees P.

    There is an alternative to Seeburger.
    DataDirect also has complete EDI-XML conversion by way of deploying a module which is called from an adapter. The range of parameters with the conversion is also quite extensive, allowing tolerance for partners who may have included non-standard EDI qualifiers and such.  The XML tags make for easier mapping.  StylusStudio XML Suite includes the EDI<->XML adapter so you can try the conversions each way directly in that package.  If you are happy with it, you need to then purchase the package from DataDirect.  We did this and implemented EDI for X12 and EDIfact, including Orders and Invoices and some other messages.  The communications part was not included.  We wrote the EDI files and used a separate process to actually send and receive the files. The IDoc <-> EDI mapping  was done using the normal graphical mapping of SAP PI. The Stylus Studio package includes the functionality to generate the XSD, which we imported to SAP PI.

  • OPI2 EDIFACT adapter - Module Exception Error

    Hi,
    We are on pI 7.0. Deployed open source custom EDI adapter (OPI2).
    Scenario: IDOC - - - xi -- - EDIFACT
    When I executed the scenario, I get the following error in comm channel monitoring.
    2010-10-14 14:19:52 Success Message successfully received by messaging system. Profile: XI URL: http://xidev:50000/MessagingSystem/receive/AFW/XI Credential (User): PIISUSER
    2010-10-14 14:19:52 Success Using connection EDIFACT_http://cbsgmbh.com/xi/EDIFACT/Adapter. Trying to put the message into the receive queue.
    2010-10-14 14:19:52 Success Message successfully put into the queue.
    2010-10-14 14:19:52 Success The message was successfully retrieved from the receive queue.
    2010-10-14 14:19:52 Success The message status set to DLNG.
    2010-10-14 14:19:52 Success Delivering to channel: CC_EDIFACT_Orders_recv
    2010-10-14 14:19:52 Success MP: Entering module processor
    2010-10-14 14:19:52 Success MP: Processing local module localejbs/opi2/edifact/CryptModule
    2010-10-14 14:19:52 Error MP: Exception caught with cause com.sap.aii.af.mp.module.ModuleException caused by: java.lang.NullPointerException
    2010-10-14 14:19:52 Error Exception caught by adapter framework: null
    Please help,
    mk

    Hi,
    I have removed "CRYPT" module from communication channel modules list since I am not using any encryption at this time. However, I get different error as below.
    MP: Exception caught with cause com.sap.aii.af.mp.module.ModuleException: Configuration lookup failed caused by: com.sap.aii.af.mp.module.ModuleException: Address normalization (alternativeID) is not defined for : agency = UNB  ZZZ  117, schema = UNBID, partyId = EDI_ATMEL
    Note: I have maintained AS2 ZZZ 117, AS2ID in both sender party & receiver party identifiers. Also, I have referred sender party and sender business system in receiver agreement header mapping.
    Please help,
    MK

  • B2B EDIFACT over Internet AS2 - 5081: XEngine error - Invalid guideline.

    Hi,
    When get message from TP on EDI EDIFACT over Internet AS2-1.1 - INVOIC
    Get an error: "5081: XEngine error - Invalid guideline."
    Version: Oracle Application Server Integration B2B, Release 10.1.2, Build B2B_10.1.2.4.0_GENERIC_091027.
    Log:
    2012.03.26 at 14:51:52:051: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:cloneSelector Enter
    2012.03.26 at 14:51:52:051: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:cloneSelector Return = oracle.tip.adapter.b2b.document.edi.ISelectorImpl@18f729c
    2012.03.26 at 14:51:52:052: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Param Name = SeverityConfig
    2012.03.26 at 14:51:52:052: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Value = null
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:cloneSelector Enter
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:cloneSelector Return = oracle.tip.adapter.b2b.document.edi.ISelectorImpl@ad97f5
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:reset Enter
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:reset Leave
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:cloneSelector Enter
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:cloneSelector Return = oracle.tip.adapter.b2b.document.edi.ISelectorImpl@d38976
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup Enter
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = InterchangeReceiverQual, val = []
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [null]
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = InterchangeSenderID, val = [SEDIS-SVS]
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [SEDIS-SVS]
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = InterchangeReceiverID, val = [DSPGROUPSBI05]
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [DSPGROUPSBI05]
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = Standard, val = [EDIFACT]
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [EDIFACT]
    2012.03.26 at 14:51:52:059: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = InterchangeControlVersion, val = [4]
    2012.03.26 at 14:51:52:060: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [4]
    2012.03.26 at 14:51:52:060: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = ec_DataNodeName, val = [Interchange]
    2012.03.26 at 14:51:52:060: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = InterchangeSenderQual, val = []
    2012.03.26 at 14:51:52:060: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [null]
    2012.03.26 at 14:51:52:060: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup return = true
    2012.03.26 at 14:51:52:060: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup return = true
    2012.03.26 at 14:51:52:060: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Param Name = ecsFileKey
    2012.03.26 at 14:51:52:060: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Value = AC16026A13648E5FAB3000001EB90540
    2012.03.26 at 14:51:52:094: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValueBlob Param Name = ecsOptFileBlob
    2012.03.26 at 14:51:52:094: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValueBlob Param Name = ecsFileBlob
    2012.03.26 at 14:51:52:564: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getStream Enter
    2012.03.26 at 14:51:52:564: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getStream Leave
    2012.03.26 at 14:51:52:565: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Param Name = SeverityConfig
    2012.03.26 at 14:51:52:566: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Value = null
    2012.03.26 at 14:51:52:807: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:setControlNumber sName = Interchange, controlNumber = 30000000000022
    2012.03.26 at 14:51:52:808: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:setControlNumber return = true
    2012.03.26 at 14:51:52:809: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Param Name = TPName
    2012.03.26 at 14:51:52:809: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Value = SIEMENS
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doCommit Enter
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doCommit NodeGUID = {757D76FE-7742-11E1-B54E-00265524F072} position = 0
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doCommit Leave
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:cloneSelector Enter
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:cloneSelector Return = oracle.tip.adapter.b2b.document.edi.ISelectorImpl@1e5c339
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup Enter
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = TransactionMessageVersionNumber, val = [D]
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [D]
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = TransactionID, val = [INVOIC]
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [INVOIC]
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = TransactionMessageReleaseNumber, val = [05A]
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [05A]
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = ec_DataNodeName, val = [Transaction]
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup key = TransactionAssociationAssignedCode, val = []
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup param = [null]
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup return = true
    2012.03.26 at 14:51:52:810: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doLookup return = true
    2012.03.26 at 14:51:52:811: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Param Name = ecsFileKey
    2012.03.26 at 14:51:52:811: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Value = BA78E50BF81BC5B0E04016AC6B024E8E-274-1-8
    2012.03.26 at 14:51:52:811: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValueBlob Param Name = ecsOptFileBlob
    2012.03.26 at 14:51:52:811: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValueBlob Param Name = ecsFileBlob
    2012.03.26 at 14:51:52:820: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Param Name = TPName
    2012.03.26 at 14:51:52:820: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:getValue Value = SIEMENS
    2012.03.26 at 14:51:52:821: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doCommit Enter
    2012.03.26 at 14:51:52:821: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doCommit NodeGUID = {757D82F2-7742-11E1-B54E-00265524F072} position = 0
    2012.03.26 at 14:51:52:821: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.ISelectorImpl:doCommit Leave
    2012.03.26 at 14:51:52:842: Thread-18: B2B - (DEBUG) iAudit report :
    Error Brief :
    5081: XEngine error - Invalid guideline.
    iAudit Report :
    <?xml version="1.0" encoding="UTF-16"?><AnalyzerResults Guid="{757D026E-7742-11E1-B54E-00265524F072}" InterchangeReceived="1" InterchangeProcessed="1" InterchangeAccepted="0"> <ExecutionDate>Monday, March 26, 2012</ExecutionDate> <ExecutionTime>02:51:52 PM (IST)</ExecutionTime> <AnalyzerReturn>Failed</AnalyzerReturn> <NumberOfErrors>1</NumberOfErrors> <ErrorByCategory> <Category Name="Rejecting"> <Severity Name="Normal">1</Severity> </Category> </ErrorByCategory> <Status>Finished</Status> <DataFile> <FilePath/> <FileName/> <LastModified/> <FileSize/> <DataURL>file://</DataURL> </DataFile> <Interchange Guid="{757D76FE-7742-11E1-B54E-00265524F072}" InterchangeAckCode="R" TransactionSetsReceived="1" TransactionSetsProcessed="1" TransactionSetsAccepted="0" RError="0" NError="0" OtherWI="0"> <DataXPointer> <StartPos>11</StartPos> <Size>9684</Size> </DataXPointer> <GuidelineInfo> <GuidelineFile> <FilePath>ByteStream</FilePath> <FileName>ByteStream</FileName> <LastModified/> <FileSize/> <GuidelineURL>file://ByteStream</GuidelineURL> </GuidelineFile> <DetailGuidelineInfo> <IID>4</IID> <ID>SS</ID> <Name>SERVICE SEGMENTS</Name> <GroupID>0</GroupID> <Standard>EDIFACT</Standard> <StdVersion>SYNTAX MESSAGES 4</StdVersion> </DetailGuidelineInfo> </GuidelineInfo> <NodeInfo> <Links> <Link Name="InterchangeControlVersion">4</Link> <Link Name="InterchangeSenderID">SEDIS-SVS</Link> <Link Name="InterchangeSenderQual"/> <Link Name="InterchangeReceiverID">DSPGROUPSBI05</Link> <Link Name="InterchangeReceiverQual"/> <Link Name="Standard">EDIFACT</Link> </Links> <Properties> <Property Name="CharSet">UNOB</Property> <Property Name="InterchangeControlVersion">4</Property> <Property Name="InterchangeDirectoryVersion"/> <Property Name="InterchangeEncoding">1</Property> <Property Name="InterchangeSyntaxReleaseNumber"/> <Property Name="InterchangeSenderID">SEDIS-SVS</Property> <Property Name="InterchangeSenderQual"/> <Property Name="InterchangeSenderAddress"/> <Property Name="InterchangeSenderSubAddress"/> <Property Name="InterchangeReceiverID">DSPGROUPSBI05</Property> <Property Name="InterchangeReceiverQual"/> <Property Name="InterchangeReceiverAddress"/> <Property Name="InterchangeReceiverSubAddress"/> <Property Name="InterchangeDate">20120326</Property> <Property Name="InterchangeTime">0300</Property> <Property Name="InterchangeControlNumber">30000000000022</Property> <Property Name="InterchangeRecipientRefPas"/> <Property Name="InterchangeRecipientRefPasQual"/> <Property Name="InterchangeAppReference"/> <Property Name="InterchangePriorityCode"/> <Property Name="InterchangeAckRequested"/> <Property Name="InterchangeAgreementID"/> <Property Name="InterchangeUsageIndicator">1</Property> <Property Name="DecimalSeparator">0x2e</Property> <Property Name="ElementDelimiter">0x2b</Property> <Property Name="ReleaseCharacter">0x3f</Property> <Property Name="RepeatingSeparator">0x2a</Property> <Property Name="SegmentDelimiter">0x270xd0xa</Property> <Property Name="SubelementDelimiter">0x3a</Property> <Property Name="InterchangeChildCount">1</Property> <Property Name="InterchangeTrailerControlNumber">30000000000022</Property> </Properties> </NodeInfo> <Transaction Guid="{757D82F2-7742-11E1-B54E-00265524F072}" TransactionAckCode="R" RError="1" NError="0" OtherWI="0"> <DataXPointer> <StartPos>87</StartPos> <Size>9585</Size> </DataXPointer> <GuidelineInfo> <GuidelineFile> <FilePath>ByteStream</FilePath> <FileName>ByteStream</FileName> <LastModified/> <FileSize/> <GuidelineURL>file://ByteStream</GuidelineURL> </GuidelineFile> <DetailGuidelineInfo> <IID>4</IID> <ID>SS</ID> <Name>SERVICE SEGMENTS</Name> <GroupID>0</GroupID> <Standard>EDIFACT</Standard> <StdVersion>SYNTAX MESSAGES 4</StdVersion> </DetailGuidelineInfo> </GuidelineInfo> <NodeInfo> <Links> <Link Name="TransactionID">INVOIC</Link> <Link Name="TransactionMessageVersionNumber">D</Link> <Link Name="TransactionMessageReleaseNumber">05A</Link> <Link Name="TransactionAssociationAssignedCode"/> </Links> <Properties> <Property Name="TransactionControlNumber">30000000000022</Property> <Property Name="TransactionID">INVOIC</Property> <Property Name="TransactionControllingAgency">UN</Property> <Property Name="TransactionMessageVersionNumber">D</Property> <Property Name="TransactionMessageReleaseNumber">05A</Property> <Property Name="TransactionAssociationAssignedCode"/> <Property Name="TransactionDirectoryVersion"/> <Property Name="TransactionMessageSubFunctionID"/> <Property Name="TransactionCommonAccessRef"/> <Property Name="TransactionSenderSequenceNumber"/> <Property Name="TransactionTransferPosition"/> <Property Name="TransactionMessageSubsetID"/> <Property Name="TransactionMessageSubsetVersion"/> <Property Name="TransactionMessageSubsetRelease"/> <Property Name="TransactionSubsetControllingAgency"/> <Property Name="TransactionImplementationID"/> <Property Name="TransactionImplementationVersion"/> <Property Name="TransactionImplementationRelease"/> <Property Name="TransactionImplemControllingAgency"/> <Property Name="TransactionScenarioID"/> <Property Name="TransactionScenarioVersion"/> <Property Name="TransactionScenarioRelease"/> <Property Name="TransactionScenarioControlAgency"/> <Property Name="TransactionChildCount">376</Property> <Property Name="TransactionTrailerControlNumber">30000000000022</Property> </Properties> </NodeInfo> <TransactionErrors> <Error ErrorCode="{AD01846F-A68B-409D-A264-AA1ECAE7FBA3}" Severity="Normal" Category="Rejecting" Index="1" ID="50810000"> <ErrorBrief>5081: XEngine error - Invalid guideline.</ErrorBrief> <ErrorMsg>Failed guideline.</ErrorMsg> <ErrorObjectInfo> <Parameter Name="ErrorLevel">0</Parameter> <Parameter Name="Name">XEngine</Parameter> <Parameter Name="_ec_dn_guid_">{757D82F2-7742-11E1-B54E-00265524F072}</Parameter> <Parameter Name="_ec_file_name_"/> <Parameter Name="_ec_index">0</Parameter> <Parameter Name="ec_error_scope">Transaction</Parameter> </ErrorObjectInfo> <ErrorDataInfo> <Part1/> <ErrData/> <Part3/> <DataXPointer> <StartPos>0</StartPos> <Size>0</Size> </DataXPointer> </ErrorDataInfo> </Error> </TransactionErrors> </Transaction> </Interchange></AnalyzerResults>
    2012.03.26 at 14:51:52:843: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:processIncomingDocument sErrorGuid = {AD01846F-A68B-409D-A264-AA1ECAE7FBA3}
    2012.03.26 at 14:51:52:843: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:processIncomingDocument sDescription = Failed guideline.
    2012.03.26 at 14:51:52:843: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:processIncomingDocument sBrDescription = 5081: XEngine error - Invalid guideline.
    2012.03.26 at 14:51:52:844: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:processIncomingDocument added Hash Key = {757D82F2-7742-11E1-B54E-00265524F072}
    2012.03.26 at 14:51:52:844: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:processIncomingDocument Error Scope = Transaction
    2012.03.26 at 14:51:52:844: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:processIncomingDocument exit
    Thanks for help
    Adi

    Hello Anuj,
    Thanks for your replay.
    Please guide me at how do I need to do the match between the Document Protocol and the Payload
    Payload file:
    UNA:+.?*'
    UNB+UNOB:4::1+SEDIS-SVS+DSPGROUPSBI05+20120326:0300+30000000000022++++++1'
    UNH+30000000000022+INVOIC:D:05A:UN'
    BGM+389+AS2 TEST'
    MOA+124:6123.70'
    UNT+376+30000000000022'
    UNZ+1+30000000000022'
    TP and HOME Document Protocol log:
    2012.03.26 at 14:51:52:041: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceB2BMsg From Document Protocol Parameters
    2012.03.26 at 14:51:52:041: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupApplicationPassword = null
    2012.03.26 at 14:51:52:041: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupTime = #SystemTime(HHMM)#
    2012.03.26 at 14:51:52:041: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeControlNumber = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeAgreementIdentifier = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeSenderInternalID = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupControlNumber = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeReceiverID = SEDIS-SVS
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeSenderQual = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter DecimalSeparator = 0x2e
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeProcessingPriority = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeReceiverInternalSubID = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter ElementDelimiter = 0x2b
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeRecipientRefPassword = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter CharSet = UNOA
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeTime = #SystemTime(HHMM)#
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeECSFileBlob
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeRecipientRefPasswordQual = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter TagDelimiter = 0x3d
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter RepeatingSeparator = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupECSFileBlob
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter TPName = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter ReplacementChar = 0x7c
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter ReleaseCharacter = 0x3f
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupSenderQual = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeCharacterEncoding = null
    2012.03.26 at 14:51:52:042: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter SegmentDelimiter = 0x27
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeApplicationRef = null
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeControlVersion = 4
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupDate = #SystemDate(YYMMDD)#
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeReceiverQual = null
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupReceiverQual = null
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter ImplementationClass = oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter SkipUNA = FALSE
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter Standard = EDIFACT
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter SubelementDelimiter = 0x3a
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter AcknowledgementOption = T2
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupAgencyCode = UN
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeServiceCodeList = null
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeDate = #SystemDate(YYMMDD)#
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeReceiverInternalID = null
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeTestIndicator = null
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeSenderID = SEDIS-SVS
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupAssociationCode = null
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupReceiverID = SEDIS-SVS
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupReleaseNumber = null
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter AcknowledgementType = CONTRL
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupSenderID = SEDIS-SVS
    2012.03.26 at 14:51:52:043: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter FunctionalGroupCreation = TRUE
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeSenderInternalSubID = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupVersion = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceB2BMsg To Document Protocol Parameters
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupApplicationPassword = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupTime = #SystemTime(HHMM)#
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeControlNumber = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeAgreementIdentifier = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeSenderInternalID = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupControlNumber = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeReceiverID = DSPGROUPSBI05
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeSenderQual = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter DecimalSeparator = 0x2e
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeProcessingPriority = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeReceiverInternalSubID = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter ElementDelimiter = 0x2b
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeRecipientRefPassword = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter CharSet = UNOA
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeTime = #SystemTime(HHMM)#
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeECSFileBlob
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeRecipientRefPasswordQual = null
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter TagDelimiter = 0x3d
    2012.03.26 at 14:51:52:044: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter RepeatingSeparator = null
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupECSFileBlob
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter TPName = null
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter ReplacementChar = 0x7c
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter ReleaseCharacter = 0x3f
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupSenderQual = null
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeCharacterEncoding = null
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter SegmentDelimiter = 0x27
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeApplicationRef = null
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeControlVersion = 4
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupDate = #SystemDate(YYMMDD)#
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeReceiverQual = null
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupReceiverQual = null
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter ImplementationClass = oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter SkipUNA = FALSE
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter Standard = EDIFACT
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter SubelementDelimiter = 0x3a
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter AcknowledgementOption = T2
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupAgencyCode = UN
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeServiceCodeList = null
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeDate = #SystemDate(YYMMDD)#
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeReceiverInternalID = null
    2012.03.26 at 14:51:52:045: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeTestIndicator = null
    2012.03.26 at 14:51:52:046: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeSenderID = DSPGROUPSBI05
    2012.03.26 at 14:51:52:046: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupAssociationCode = null
    2012.03.26 at 14:51:52:046: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupReceiverID = DSPGROUPSBI05
    2012.03.26 at 14:51:52:046: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupReleaseNumber = null
    2012.03.26 at 14:51:52:046: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter AcknowledgementType = CONTRL
    2012.03.26 at 14:51:52:046: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupSenderID = DSPGROUPSBI05
    2012.03.26 at 14:51:52:046: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter FunctionalGroupCreation = TRUE
    2012.03.26 at 14:51:52:046: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter InterchangeSenderInternalSubID = null
    2012.03.26 at 14:51:52:046: Thread-18: B2B - (DEBUG) oracle.tip.adapter.b2b.document.edi.EDIDocumentPlugin:traceParameters Parameter GroupVersion = null
    Thanks
    Adi

  • XI supports EDIFACT without SAP Conversion Agent and others.

    Hello.
    Somebody knows the best way to convert EDIFACT message using XI?
    What I can do this without using softwares of conversion like:
    - SAP Conversion Agent;
    - Seeburger;
    - BIC Mapper and others.
    Thanks very much in advance.

    Hi,
    See for converting the EDI XML to EDI you need to have a mapping program at the adapter module which does the conversion. For this module you need a BIC tool of seeburger which provides the different module program for EDI to XML and XML-EDI. This program needs to be deployed on XI and through adapter it has to be called for conversion.
    Here is the link for your reference:
    /people/ricardoandres.maienza/blog/2007/04/06/edifact-to-xml--stylus-studio-solution
    http://www.stylusstudio.com/edi/EDIFACT_translate.html
    The steps to convert EDI to XML / XSD can be found at the following link:
    http://www.stylusstudio.com/edifact_to_xml.html
    Stylus studio download link: http://www.stylusstudio.com/xml_download.html
    Thanks and Regards,
    Chirag Gohil

Maybe you are looking for