Element resets to zero after sub vi runs

Hi all,
I want to use the following code to slowly and continuously ramp up laser power. The sub vi called scan does the ramping but after it has ramped all the say up to the set power it resets to zero. I have been working for awhile trying to figure out how to the variable element set to the final desired power after the ramping has finished but I can't figure out a way that works. I'm curious if anyone has any suggestions!
Thanks, 

Well there's your problem, at least the one causing your drop: your index input will keep going up with each iteration, but your array inside the VI is only so large. Once the index goes above the array size, it tries to index past the end and will therefore output the default value of zero. To fix this, put a Select node that is controlled by your x=y? boolean output. If True, output the "Stop" input value and ignore the indexed value.
DISCLAIMER: This should fix your immediate problem that you're asking about, but your code in general will most likely have other issues. There are better ways to ramp a signal.

Similar Messages

  • Volume reset to zero after restart

    i have a problem with my system, i dont have any answer, why my front channel volume always reset to zero after i reboot my system??
    could anyone help me??
    thx before...
    sorry for my english...

    thanks a lot,i was having the same problem as well
    OP: please mark this thread as SOLVED

  • Useage stats dont reset to zero after full charge?

    hi all, i thought that, after a full charge, the useage stats, ie, time in use and standby, went to zero. i am getting the full charge indicator but the stats continue to run up and not get reset to zero. am i missing something? uj thanks.

    Are you getting the little plug icon (vs the lightening bolt) in the battery? That is when the iPhone recognizes a full charge, despite how "full" the battery actually appears. If you have been chraging via your wall unit, try to "top off" using the USB. I did that this morning, and as soon as my iPhone had completed a sync, I got the battery symbol and my usage stats reset. Some people have also reported doing it vice versa, and topping off via the wall unit if they have been charging via the USB. Good luck.

  • Why is the does indicator cluster values reset to zero after execution?

    I'm using a cluster to contain a selection of indicator. Each indicator has a propery node, the value being sent to the node is the output from a color box constant. A terminal gets associated with the indicator cluster. When I run the program the values get routed to the indicator but quickly reset to zero. If I remove an indicator from the cluster and run the program the indicator stores the value. Why is the indicator values resetting when placed in a cluster?

    I've answered this question some hour ago but I see it's still unanswered, so something went wrong.
    I think you are bumping against a race condition i.e. you read a value of a control or indicator and change it inside the same loop, LV does not accept it.
    If your cluster is an indicator you can create its local variable, change it to read mode, unboundle, change the values of the indicators you want, boundle them back and in the next loop you can set the new value of the cluster (you should use a shift register).
    You can use an alternative method that lets you change the values you want of the indicators in your cluster in the same loop. It is based on the property nodes of the cluster, see sample vi attached.For a description of the property node used open the help
    window.
    Hope it helped.
    [email protected]
    Attachments:
    cluster_updates.vi ‏19 KB

  • How can i get rid of the zeroes after sub-division of arrays?

    Hi
    i have sub-divided a long 1-D array (50000 samples) into a number of smaller sub-arrays with different lengths build in a 2-D array. What happened is, where the sub-arrays end, Labview adds zeroes to them to match the length of the biggest array (558 length). How do i get rid of the zeroes?I just need to have the actual length of each sub-array with now zeroes to it. I have attached my vi
    Thank you
    Attachments:
    Untitled2.vi ‏419 KB

    Hey guys,
    when posting examples, don't retain bad programming, even if it only occurs as a side issue. New LabVIEW users will copy everything posted here as gospel!
    Ben's workaround is sound, but please refrain form keeping a "cruncher loop". An empty loop without wait will consume all CPU and possible starve all other running processes for no good reason. That polling loop needs a small wait statement!
    An empty loop without any wait statement will:
    Will spin millions of times per second using 100% of the CPU.
    run many iterations before allowing a thread switch.
    Add 10 such loops in any program and the program will be unusable (thread gobbling!).
    Even a 1ms wait will reduce the CPU consumptions by many orders of magnitude.
    Even a 100ms delay will not noticeably delay any user actions.
    Waiting for a button press is not something that needs to be handled within nanoseconds.
    Cruncher loop!
    Easy correction: place a smal wait inside that loop!
    Message Edited by altenbach on 04-11-2007 05:12 PM
    LabVIEW Champion . Do more with less code and in less time .
    Attachments:
    cruncherloop.png ‏12 KB

  • Play counts resetting to zero after reaching 100 plays

    I've recently noticed my top played songs drop out of my 25 most played songs smart playlist. It seems to happen every time a song reaches 100 plays. Any ideas on a fix? Also is it possible to manually amend the play counts to get the 2 songs that this has happened to back to their correct play count?

    That is an odd bug. I read one report that iTunes 11 has a playcount bug where if you have "crossfade" enabled it won't increment the play counts. I haven't personally verified that one.
    As for manually incrementing the play counts. This Stack Exchange thread offers several possible methods: http://apple.stackexchange.com/questions/76576/how-do-i-correct-wrong-itunes-pla y-counts

  • Unsuccessful Login Notification Does Not Reset To Zero

    Dear all,
    os: OUL5x64
    ebs R12 12.0.6
    db 10.2.0.4
    when users connect to the application and login with the wrong password
    On 12.0.6 in Production:
    When attempting to login the applications Find that Unsuccessful login notification always
    displays a cumulative count of unsuccessful logins every time. It does not reset to zero
    after you successfully login.
    Please advise how to fix this notification.
    Thanks,

    Hi,
    Please see (Note: 848921.1 - Unsuccessful Login Notification Does Not Reset To Zero).
    Regards,
    Hussein

  • Add 3 zero after every n element in an array

    Hi, I have an array that has 50 elements ( 0 and 1) . I would like to add 3 zero after every 5 elements . As below for the first 10 elements
    10101010111111101001 should become  10101010110001111101001000
    could you please help me on this one ? I would greatly appreciate if youd attach the code for it
    thanks

    Approach with for loop
    "In theory, theory and practice are the same. In practice, they’re not."

  • How can main vi detect whether sub-vi closes after opening and running it by user?

    Hi I learned more using the call by reference node function.
    From what I know is that, after opening and running subvi by means of method nodes.
    So after running it, "call by reference" node stays active and there is no flow of data coming out of it till it is closed.
    However what if I do not want to use this "call by reference" node as I have multiple sub-vis to choose. So how does the main program detect that any one of sub-vi is closed by user?
     regards,
    Clement

    Hi Clement,
    first: you may run the vi with the option "wait until completion" set to false, the call-by-reference node will return promptly.
    2nd:
    There are many options to signal the completion of the subvi to the main vi: globals (easiest, but may lead to race conditions), LV2-style global, queues. You can even check the status of the subvi (running or not) via vi server.
    Best regards,
    GerdW
    CLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 on WinXP+Win7+cRIO
    Kudos are welcome

  • Have been advised by my email provider (recently blocked account requiring password reset) that they will only reset the password after a proven anti viru and malware scan has been done on ipad and iphone. Is this necessary and if so what do i use

    Have been advised by my email provider (recently blocked account requiring password reset) that they will only reset the password after a proven anti virus and malware scan has been done on ipad and iphone. Is this necessary and if so what do i use

    As KP has pointed out, there actually aren't any anti-virus programs in the App Store. There are a few that allow you to scan e-mail or stuff like that, and a few that provide you with information about malware and new threats for other systems. But none are available that can scan your iOS device for malware, because the security restrictions in iOS do not permit any apps to have that kind of access to anything. Which means that you also cannot be infected with a virus (unless you have jailbroken your device).
    If your account got compromised, that had nothing whatsoever to do with your iPad. Someone simply hacked it remotely. Happens all the time. It's really amazing that, in this day and age, e-mail providers are so ignorant of technology and how their own systems get compromised that they would try to require you to run software that does not exist!

  • Mass Contract Update - Item price become zero after Tax Code change

    HI Guru,
    I have issue on the contract net price which become zero after change in Tax code of item.
    Took the opportunity to update contracts to reflect the changing VAT code (from V0 to V1 for some items) from the Trx code: MEMASSCONTRACT. However, having run the transactions (ME33K) above the contracts are now displaying zero prices on the Item Overview.  The conditions are all correct (PB00) and the follow on purchase orders seem to be picking up the correct prices but we need to resolve the issue of zero prices on the item overview. 
    Please help me in this why it is happening like this? & what is the solution for it.
    Thanks in advance
    Praveen Katageri

    Hi,
    If pricing picking , just check  validity period ( Valid from & Valid to) in  condition of the  Info record.Also check any scale is used & price active or not in condition of Info record.
    Regards,
    Biju K

  • When are Redolog files reset to zero size? Manual reset possible?

    As far as I know redolog files contain all stuff which is changed during operation of an Oracle database.
    However I wonder if there are events when these files are AUTOMATICALLY reset to zero.
    I guess it is when I do a full offline backup.
    Is this correct?
    Are there any other events when this happens automatically ?
    How can I manually reset/initialize Redolog files to an empty state?
    Peter

    What did you mean empty redo logfile?
    if you mean zero size on redolog files....
    We can not reset redo log files to empty (zero).
    I guess it is when I do a full offline backup.That mean your database offline... no operation, so no redo log generate. but not mean you can make redo log empty anyway...
    If you mean redo log file no need for instance recovery.
    redo log groups have "INACTIVE" status -> is no longer needed for instance recovery. It may be in use for media recovery. It might or might not be archived.
    check from v$log
    UNUSED - Online redo log has never been written to. This is the state of a redo log that was just added, or just after a RESETLOGS, when it is not the current redo log.
    CURRENT - Current redo log. This implies that the redo log is active. The redo log could be open or closed.
    ACTIVE - Log is active but is not the current log. It is needed for crash recovery. It may be in use for block recovery. It may or may not be archived.
    CLEARING - Log is being re-created as an empty log after an ALTER DATABASE CLEAR LOGFILE statement. After the log is cleared, the status changes to UNUSED.
    CLEARING_CURRENT - Current log is being cleared of a closed thread. The log can stay in this status if there is some failure in the switch such as an I/O error writing the new log header.
    INACTIVE - Log is no longer needed for instance recovery. It may be in use for media recovery. It might or might not be archived.;)

  • "fpsane.cpp" in line 269 appears when trying to save ma VI after the 1st run!

    Hi LV-users,
    this is a problem some of you may had before. But I still don't know how to solve this problem.
    LV crashes when I try to save my VI after the 1st run telling me about the fpsane.cpp-error. It also tells about "INSANE object at FPHP+3EE4 in my VI" and it says
    "{sub } (0x10)wave chart" and so on.
    I wonder if their is a mistake in a sub VI, maybe because I'm working with references for my wave charts and their histograms which have to be saved if the acquired datapoints are not within tolerance.
    I already upgrades my LV-Version to 6.02 and so on...I read about this solution in the Discussion Forum.
    I added my VI and Sub VIs using references.
    Can anybo
    dy give me some advice?
    Thanks, Kathrine
    Attachments:
    2405_D_Kurven_in_Cluster.vi ‏199 KB
    Kurven_Sichtbar.vi ‏38 KB
    3_Historie_speichern_B.vi ‏51 KB

    Insane error are not due to your programming. There are several good pages on our site that discuss solving these errors. Goto www.ni.com >> support >> advanced search (it is at the bottom--click on the words). This lauches the best way to search our site because under option 2, you can limit your search to resources of interests. Enter insane in the all the words field and search everything. One of the first hits is a knowlegbase that discusses solving this issue.
    Jeremy Braden
    National Instruments

  • PCI-6601 - Group Config error -10444 after 9 hours running

    We developed a vi in order to acquire from the unique dma channel of the PCI-6601 counter 4 multiplexed inputs for a period measurement. We use the national VI buffered_measured_period_TIO. Each cycle the VI is supplied with one of the 4 input line.
    Everything works fine until the 32211 second of measurement (about 9 hours) and after we receive the -10444 error on the group config block and the card freezes (not the software). We need to switch off and on again the PC to start again.
    The cycle of measurement is exactly the one from the original Ni Vi and each cycle the reset is performed.
    Looking in the database we found a similar problem after a long running (10hours) and a PCI-6602.
    We suppose that after s
    everal initialization some internal counter goes in overflow (maybe the TAskID counter?).
    Does exist any explanation and workouround to solve this?
    Is it possible initialize the card only one time for the 4 channel and how?
    Regards
    Andrea Pede

    Hi Andrea,
    What is probably happening is that your memory is becoming increasingly fragmented and after 9 hours there are no continuous blocks of memory available. If you are continuously reconfiguring your counters, that is what is morelikely causing the problem. I included an example that uses all 8 counters and only needs to configure them once. A couple other suggestions:
    1) What happens when you create a larger buffer? Can you run the program for longer?
    2) Have you tried running a disk defrag program on your memory? One suggestion I found on the net was mem-turbo from a shareware site.
    3) What happens if you only use 1 counter? Does the error still occur?
    4) Some issues (including error 10444) with the NI-DAQ driver and analog input were solved
    by upgrading to NI-DAQ 6.9.3. What is your current computer configuration (software, hardware, driver version etc.)? This might help narrow the problem down.
    Simultaneous Buffered-Event Counting on All Eight Counters of the 6602 or 6608 Devices
    http://sine.ni.com/apps/we/niepd_web_display.display_epd4?p_guid=B45EACE3DC9F56A4E034080020E74861&p_node=DZ52325&p_source=External
    Hope that helps. Have a good day.
    Ron
    Applications Engineering
    National Instruments

  • ITunes/Photoshop Elements Photo Sync Fails After PSE Upgrade

    After upgrading from Photoshop Elements version 9 to version 13, the iTunes "Sync Photos from Photoshop Elements" feature no longer works.
    iTunes continues to show the albums from version 9, and photo syncing any of the albums causes iTunes to fail into an un-ending loop without an error message. Photo syncing from other folders works fine.  I temporarily re-installed Elements 9 and iTunes photo sync began to work, but using the old version 9 photo catalog.
    Is there a fix that will get iTunes to sync with Elements 13 photo albums? Are there files or registry entries that need to be re-pointed to the Elements 13 photo catalog?
    I'm running Windows 7 with SP1 and iTunes 12.0.1.26 on a very capable HP PC.
    All help appreciated.
    Thanks ... Tom

    While I haven't heard a solution to posts I've made to both Adobe and iTunes sites, I have found a manual workaround.
    The catalog files that iTunes uses are of the format "catalog.pseXdb". 
    In my case, the new catalog is "catalog.pse13db" and the old is "catalog.pse9db". These files are found in catalog folders like: C:\ProgramData\Adobe\Elements Organizer\Catalogs\Elements 9 Catalog
    With iTunes and PSE closed,
    1) copy the catalog.pse13db file to the "Elements 9 Catalog folder. 
    2) rename the old catalog.pse9db file to keep it and deactivate it
    3) rename catalog.pse13db to catalog.pse9db
    iTunes will continue to use the older catalog file, but it now has new catalog contents.  The manual part is that this will need to be done prior to each time you want to sync new catalog content to your devices.
    Somewhere around PSE version 7, the catalog file format changed, so this technique may not work for upgrades from about v7 upward.

Maybe you are looking for

  • Thtmlb:cellerator: color in a single row

    Hi, I have a thtmlb:cellerator which is showing 5 rows. I want that las row has a background color in yellow (for example). I have tried to do this in the iterator, in method IF_HTMLB_TABLEVIEW_ITERATOR~RENDER_CELL_START, setting the value of paramet

  • Custom field in 'Notes and Attachment" tab of shopping cart

    Hi All, I am working in SRM 7.0 classic scenario and i have requirement in which i need to add custom field in 'Notes and Attachment" tab of the shopping cart portal. I have added those fields in structure --- INCL_EEW_PD_ITEM_CSF and INCL_EEW_PD_ITE

  • Thumbnails created when I creat document in easy DMS

    Hello, Can somebody help to analyze this problem?  When I creat a document and attach an original file to the document in easy DMS, there will be a thumbnail created meanwhile. This is not expected, and can you tell me why and how to avoid this? Than

  • Financial Accounting - Org. Structure

    Hi Gurus, Please tell me about FI Org Structure? What all things should be included in FI Org Structure? It will be good if you explain me through example. waiting for your reply. Thank You

  • Mass component substitution in Task List

    Hi Gurus, I'have so many Task Lists, and total have hundreds of line operations. But, now there material substitution. Let say, previously in Taks List using Material/Component "A", and now material "A" substituted become material/compenent "B". How