Hello Experts,
I think I have encountered an error in the functionality of the S_ALR_87013431 "Confirmation Using Operation List" in ECC 6.0.
When I select the "collective time confirmation" checkbox, the intended functionality is (form the transaction help) "If you select this field, the report program enters the selection result directly in the collective entry screen, without previously displaying a list of results from which you can reselect."
However, if I check the box, the results still don't appear directly in the collective entry screen, but still as a list of results.
Is there some configuration missing? Have you encountered a similar error?
Thanks!
Andreas

hi
i think there is some problem with the transaction ,in easy access menu it is displayed as S_ALR_87013431 confirmation with operation selection.
i think same screen it has incorporated
you can use IW48 which fullfil your requirement
regards
thyagarajan

Similar Messages

  • What r the diff. error that can be solved using RSRV tcode?

    Hi ,
    what r the diff. error that can be solved using RSRV tcode?
    I want to know all the errors that can be solved using RSRV t code
    if any body is having good document regarding RSRV please send it to me at
    <u><b>[email protected]</b></u>
    Thanx in advance,
    ravi.

    Hi,
    Refer the below links for more details about RSRV TCODE.
    /community [original link is broken]
    http://help.sap.com/saphelp_nw04/helpdata/en/92/1d733b73a8f706e10000000a11402f/frameset.htm
    it's for bw objects consistency analysis and repair.
    from transaction code RSRV doc itself :
    Transaction RSRV: BW Data and Metadata Test and Repair Environment.
    Transaction RSRV checks the consistency of data stored in BW. It mostly examines the foreign key relationships between individual tables in the enhanced star schema of the BW system.
    The transaction interface was re-designed for SAP Portals release 3.0A. A brief guide about how to use the transaction follows.
    Starting the Transaction
    You can reach the test and repair environment
    By entering the transaction code RSRV
    From InfoObject maintenance (Transaction RSD1)
    By clicking on the "Analyze" button in the intial screen.
    After selecting a characteristic in the maintenance screen via the "Processing -> Analyze InfoObject" menu option.
    The Initial Screen
    When using the test and repair environment for the first time, the message "Values were not found for all setting parameters" draws your attention to the fact that there aren't any saved settings for your user.
    After confirming the dialog box, you reach the initial screen of the transaction. This is divided into two parts:
    1. On the left-hand side, you can see a tree structure with the pool of available tests.
    2. The right-hand side is empty at first. The tests you have selected will be put here. A selection of tests is called a Test Package here.
    Combined and Elementary Tests
    An Elementary Test is a test that cannot be divided into smaller tests and that can therefore only be executed as a whole.
    In this regard, a Combined Test determines which elementary tests are to be executed after entering the parameters. You can remove individual elementary tests from the test package before carrying out the actual test run, in order to reduce run time, for example.
    Combining a Test Package and Executing it.
    Firstly select one or more tests with drag&drop or by double-clicking. Each selected test appears as a closed folder in the view of your test package. (An exception is elementary tests without parameters: These do not appear as a folder). You can also drag a whole folder of tests from the test pool across to the right-hand screen area; all tests that are located in the hierarchical structure under this folder are then added to the test package. You can also display a short description of the test, if required. Do this right-clicking on a test and choosing "Description" from the context menu.
    Afterwards, you must supply the tests with parameters. Tests without parameters must not be given parameters. You are given notification of this when selecting them. You can enter parameters by double-clicking on a test (or a test package) or by expanding the folder of the test.
    A dialog box appears in which you must enter the required parameters. Input help is often available. After entering the parameters, a folder with the name "Parameter" is added under the test. This contains the parameter values. The test name can change in some circumstances, enabling you to see at first sight for which parameter values the test is to be executed. It is possible to select the same test several times and give it different parameters, which may even be preferable in some situations. When you have supplied the combined test with parameters, the folder with the name "Elementary Tests" is added under this one. It contains the elementary tests, from which the combined test is built. You can delete individual elementary tests in the test pool using drag & drop.
    After supplying all tests with parameters, you can start the test run by clicking on the "Execution" button. After execution, the test icons change from a gray rhombus to a red, yellow or green one, depending on whether the test had errors, warnings or was error-free.
    Test Results
    The test results are written to the application log. Depending on the settings, the system jumps automatically to this display, or you can reach it by clicking on the "Display" button. The results are saved in the database, and can therefore be compared later with additional test runs.
    In the left-hand side of the window, you can see an overview of the most recent test runs. Double-clicking on a folder displays all messages under these nodes as a flat (non-hierarchical) list in the right-hand screen area. Long texts or detail data may be available for individual messages, which can be displayed with a mouse click.
    Repairs
    Some tests can repair inconsistencies and errors. Automatic correction is generally not possible: If entries are missing from the SID table for a characteristic, in which case the lost SIDs are still being used in a dimension table (and the corresponding dimension keys are still being used in the fact table) of an InfoCube, you can only remove the inconsistency by reloading the transaction data of the InfoCube. Also note that you must make repairs in the correct sequence. You must always read the documentation for the test and have a good idea about how the error occured, before making the repairs.
    After executing the test run, go from the application log back to the initial screen to make these repairs. Click on the "Fix Errors" button to start an error run. Since the dataset could have changed between the test and the repair run, the required tests are executed again before the actual repair. The results can be found in the application log once again.
    Test Packages
    The test package is deleted if you do not save the test package in the display before leaving the test environment. Choose "Test Packages -> Save Test Package" in the option menu. You can do the following via options in the "Test Package" menu:
    Load packages
    Load for processing - the package is then locked against changes by others.
    Delete and
    Schedule execution at a later date or at regular intervals in background processing
    Settings
    In the "Settings" menu option, you can make settings (adjust the size of the screen areas, for example) and save them. The settings are automatically read when starting the test environment. Support packages are being delivered with additional settings options since the test environment is under development at the moment. A message notifies the user at the start if there aren't any values for the setting options.
    Jobs Menu Option
    You can access the job overview via the Jobs -> Job Overview menu. Use this when you want to check the status of a test package you have scheduled.
    Application Log Menu Option
    You can display old logs from previous test runs in the dialog box, as well as scheduled ones. The option of deleting test logs can also be found here.
    New Selection Button
    The currently selected test package is deleted when you press this button.
    Filter Button
    After a test run, click on this button to remove all elementary tests without errors or warnings from the test package.
    Executing Test Packages in Process Chains
    You can add a process chain to the ABAP Programm RSRV_JOB_RUNNER in the process chain maintenance transaction, RSPC. To do this, use drag & drop to select the process type "ABAP Program" under "General Services" in the process type view. When maintaining process variants you will be asked for the program name and a program variant. Enter RSRV_JOB_RUNNER for the program name. Choose a program variant name and click on "Change". In the next screen you are able to either change or display an already existing variant, or create a new variant. When creating a new variant you will be asked for the following: Package name (an imput help on this is available), the detail level for the log to which the RSRV log in the process chain log is to be integrated, and a message type severity at which process chain processing should be terminated.
    The RSRV process log in the process chain is built as follows:
    First is a summary specifying whether errors, warnings, or no errors occurred for each elementary test.
    A log view of the RSRV test package at the specified detail level follows.
    Example: If you choose the value '3' for the detail level, only messages up to and including detail level 3 will be included in the log processes for the process chain. Messages occuring at a lower layer of the test package test are not displayed in this log. Please note that, unlike the application log, the process log does not propagate errors from deep detail levels to low detail levels. For example, if a single detail level 4 error occurs the summary will show that the relevant test delivered an error. However, this error will not be listed in the second part of the log.
    A complete log is always written independantly of the RSRV process log in the process chain. You can view this in the menu option "Application Log->Display Log->From Batch".
    Please note that there is currently no transport object for test packages and that consequently these cannot be transported. Process chains that execute RSRV test packages must therefore be manually postprocessed after a transport to a different system: The relevant test packages must be created.
    Hope This Helps,
    This is already there in SDN.
    Regards,
    rik

  • Error while exporting data via Tcode CNS43 by using spreadsheet(XXL) option

    Hello All,
    User tries to download data to spreadsheet via Tcode CNS43 by using spreadsheet(XXL) option. user gets following error.
    Selected key figure STUFE not contained in XXL output structure
    Message no. M5180
    Diagnosis
    You tried to export a key figure that is not contained in the definition of the internal table 'xxl_data'. The key figure, therefore, cannot be exported.
    System response
    The system ignored the key figure column when exporting.
    Procedure
    The table definition for 'xxl_data' must be corrected by the development department responsible for the application.
    Please note that user doesnt want to use 'save to file' option.
    Any help?

    Refer SAP notes 761839, 522925
    Regards

  • WebPart is raising the following error "Invalid data has been used to update the list item.The field you are trying to update may be read only"

    I have created a farm solution and then i deploy it to SharePoint server, the code looks as follow, and i use it to update a page info values (as the current page values represents old info):-
    [ToolboxItemAttribute(false)]
    public partial class VisualWebPart1 : WebPart
    // Uncomment the following SecurityPermission attribute only when doing Performance Profiling using
    // the Instrumentation method, and then remove the SecurityPermission attribute when the code is ready
    // for production. Because the SecurityPermission attribute bypasses the security check for callers of
    // your constructor, it's not recommended for production purposes.
    // [System.Security.Permissions.SecurityPermission(System.Security.Permissions.SecurityAction.Assert, UnmanagedCode = true)]
    public VisualWebPart1()
    protected override void OnInit(EventArgs e)
    base.OnInit(e);
    InitializeControl();
    using (SPSite site = new SPSite(SPContext.Current.Site.Url))
    using (SPWeb web = site.OpenWeb())
    SPList list = web.Lists["Pages"];
    web.AllowUnsafeUpdates = true;
    foreach (SPListItem items in list.Items)
    items["Author"] = "SharePoint";
    items["Created"] = "01/08/2014 01:44 PM";
    items.Update();
    list.Update();
    web.AllowUnsafeUpdates = false;
    protected void Page_Load(object sender, EventArgs e)
    but when i try adding this web part to a page i got the following error:-
    Invalid data has been used to update the list item.The field you are trying to update may be read only
    so can anyone advice?

    i only changed lines bitween 
    web.AllowUnsafeUpdates = true;
    and
    web.AllowUnsafeUpdates = false;
    and other parts of code remains without change
    so it will updates all pages in current web
    yaşamak bir eylemdir

  • Error: "Function or method not supported." when using RF List Mode on NI 5673E

    Hi,
    I am trying to use the RF List Mode in NI RFSG 5673E. I tried running the sample code "RFSG Configuration List Frequency and Power Sweep.vi" but an error would show up:
    "Error: niRFSGCreateConfigurationList.VI <ERR> The LO reported the following error: Function or method not supported." with the error code: BFFA4239. 
    I also tried running other sample codes that contain the Configuration List VI's but the same error appeared. I am using NI RFSG 1.8.5.
    I would really appreciate any help on this. Thanks!

    Hello jdlabrador,
    I setup a 5673E here and tried to run the same example.  I did not encounter an error.
    Other reports I've found pertaining to this error usually involved a large number of steps - there was not enough space on the hardware to accommodate them.  The error text you're seeing is a little different in that it states that the Create Configuration List method isn't supported for the LO.
    Do each of the modules in your 5673E (5450, 5611, 5652) pass a self-test in MAX?  
    Have you associated the 5450 and 5652 with the 5611?
    Could you post a screenshot of the fully-expanded Devices and Interfaces tree from MAX?
    Since RFSG 1.9.5 is available, it may be a good first-step to upgrade to it.  
    Best regards,
    Matthew H.
    Applications Engineer
    National Instruments

  • I'm running Mac OS X version 10.6.8 How come I get this error message "You are running an operating system that Photoshop no longer supports. Refer to the system requirements for a full list of supported platforms." When I Try to download a FREE trail?

    I'm running Mac OS X version 10.6.8 How come I get this error message "You are running an operating system that Photoshop no longer supports. Refer to the system requirements for a full list of supported platforms." When I Try to download a FREE trail?

    Hi Brizill,
    Please refer to the help document below to understand the technical specifications for the same:
    System requirements | Photoshop
    Regards,
    Sheena

  • Error in activity confirmation using CATS

    Dea all,
    While doing activity confirmation using cats in the transaction CATA following error is occuring:
    CATS: Transfer to Project System
    No records for transfer to PS
    kindly help.
    regards,
    sudhir

    Hi
    First record the time in CAT2 t.code
    Then transfer the time to project system using CAT5 t.code.
    Do you followed the above t.codes?
    In selection screen what are the selection parameters have you maintained?
    Thanks
    S.Murali

  • Qa32-confirm the operation before proceeding error even though operation is confirmed.

    Hi,
    In qa32, while doing ud and while saving, it is showing the error message as confirm the operation before proceeding.even though the operations are confirmed. we are doing the co1f conformation.please find the screenshots for the issue.
    we are 3 in process inspections operations with operation nos 25,65,75. The 25,65 operations we are closing in qa32 with force closer. i.e when operation 75 doing ud, the inspection operations 25,65 happening force closer. But in order even though operations are confirming also,it is showing the below error message while doing ud in qa32. Please help me on this. why it is showing that error message even though operations are confirmed.
    Regards,
    Mastan.

    Memory errors have nothing to do with actual lack of RAM. The file is damaged or references a potentially critical external component like a specific printer driver whose info has been stored in the file, a font, a color profile, a linked image or whatever. You need to figure out those problems instead of blindly throwing more resources art the program. As a start, try to open the file on another system. If it works you can limit the investigation to the specific machine and even if it doesn't it may give you a more meaningful warning that helps to diagnose the error.
    Mylenium

  • UIX Tip - maybe of use to somebody - confirm Delete operation with Javascript popup

    It was easier than I thought it would be to convert my Javascript Delete Confirmation message that I had developed for my JSP over to UIX:
    By default UIX would generally do something along the lines of:
    <submitButton text="Delete" ctrl:event="delete" />
    which generates the following html:
    <a href="# onclick="submitForm('viewForm',1,{'event':'delete');return false">
    If you want to popup a Javascript window asking the user to confirm the operation you can do:
    <submitButton text="Delete" ctrl:event="delete">
    <boundAttribute name="onClick">
    <fixed javaType="string">javascript:if (confirm("WARNING: You will not be able to revert this operation. This operation will also fail if there are dependant objects!")){return true;}else{return false;}</fixed>
    </boundAttribute>
    </submitButton>
    this will generate the following html:
    <a href="#" onclick="return _chain('javascript:if (confirm(&quot;WARNING: You will not be able to revert this operation.  This operation will also fail if there are dependant objects!&quot;)){return true;}else{return false;}','submitForm(\'viewForm\',1,{\'event\':\'delete\'});return false',this,event,true)">
    Matt.

    This is a totally supported technique, and a good one.
    To pick at nits, you don't need to start "onClick" handlers with "javascript:". Save yourself a whopping
    11 bytes by trimming that off. With a bit of slyness, you could boil this down to:
    <boundAttribute name="onClick">
       <fixed javaType="string">return confirm("WARNING: You will not be able to revert this operation.  This
    operation will also fail if there are dependant objects!");</fixed>
    </boundAttribute>... or, just extract that into a script, like:
      <script><contents>function makeSure()
      return confirm("WARNING: You will not be able to revert this operation.  This operation will also fail
    if there are dependant objects!");
    }</contents></script>
      <submit text="Delete" ctrl:event="delete" onClick="return makeSure()"/>

  • Error al iniciar "USING OPERATING SYSTEM"

    Hola,
    Tengo un ThinkCentre Edge 72 el cual al iniciar el equipo aparece el mensaje "using operating system" y de ahí no pasa.
    He intentado entrar en la BIOS para restablecer los valores por defecto pero no entra en BIOS directamente aparece de nuevo ese mensaje.
    Alguien tiene idea de que puede ser?.
    Saludos y gracias,

    Hola RichiRS. Por lo que comentas puede ser un problema de la información contenida en el disco (particiones, sistemas de archivos, etc) y por eso el sistema operativo no arranca.
    Mi recomendación es que saques el disco y lo conectes a otro equipo (directo por cable SATA o bien utilizando un dock) para que puedas ver si tienes acceso a la información.
    Saludos.
    IPnaSh
    First Spanish Community Guru - Colaborador ad honorem

  • Error in creating a process using runtime class - please help

    Hi,
    I am experimenting with the following piece of code. I tried to run it in one windows machine and it works fine. But i tried to run it in a different windows machine i get error in creating a process. The error is attached below the code. I don't understand why i couldn't create a process with the 'exec' command in the second machine. Can anyone please help?
    CODE:
    import java.io.*;
    class test{
    public static void main(String[] args){
    try{
    Runtime r = Runtime.getRuntime();
         Process p = null;
         p= r.exec("dir");
         BufferedReader br = new BufferedReader(new InputStreamReader(p.getInputStream()));
         System.out.println(br.readLine());
    catch(Exception e){e.printStackTrace();}
    ERROR (when run in the dos prompt):
    java.io.IOException: CreateProcess: dir error=2
    at java.lang.Win32Process.create(Native Method)
    at java.lang.Win32Process.<init>(Win32Process.java:63)
    at java.lang.Runtime.execInternal(Native Method)
    at java.lang.Runtime.exec(Runtime.java:550)
    at java.lang.Runtime.exec(Runtime.java:416)
    at java.lang.Runtime.exec(Runtime.java:358)
    at java.lang.Runtime.exec(Runtime.java:322)
    at test.main(test.java:16)
    thanks,
    Divya

    As much as I understand from the readings in the forums, Runtime.exec can only run commands that are in files, not native commands.
    Hmm how do I explain that again?
    Here:
    Assuming a command is an executable program
    Under the Windows operating system, many new programmers stumble upon Runtime.exec() when trying to use it for nonexecutable commands like dir and copy. Subsequently, they run into Runtime.exec()'s third pitfall. Listing 4.4 demonstrates exactly that:
    Listing 4.4 BadExecWinDir.java
    import java.util.*;
    import java.io.*;
    public class BadExecWinDir
    public static void main(String args[])
    try
    Runtime rt = Runtime.getRuntime();
    Process proc = rt.exec("dir");
    InputStream stdin = proc.getInputStream();
    InputStreamReader isr = new InputStreamReader(stdin);
    BufferedReader br = new BufferedReader(isr);
    String line = null;
    System.out.println("<OUTPUT>");
    while ( (line = br.readLine()) != null)
    System.out.println(line);
    System.out.println("</OUTPUT>");
    int exitVal = proc.waitFor();
    System.out.println("Process exitValue: " + exitVal);
    } catch (Throwable t)
    t.printStackTrace();
    A run of BadExecWinDir produces:
    E:\classes\com\javaworld\jpitfalls\article2>java BadExecWinDir
    java.io.IOException: CreateProcess: dir error=2
    at java.lang.Win32Process.create(Native Method)
    at java.lang.Win32Process.<init>(Unknown Source)
    at java.lang.Runtime.execInternal(Native Method)
    at java.lang.Runtime.exec(Unknown Source)
    at java.lang.Runtime.exec(Unknown Source)
    at java.lang.Runtime.exec(Unknown Source)
    at java.lang.Runtime.exec(Unknown Source)
    at BadExecWinDir.main(BadExecWinDir.java:12)
    As stated earlier, the error value of 2 means "file not found," which, in this case, means that the executable named dir.exe could not be found. That's because the directory command is part of the Windows command interpreter and not a separate executable. To run the Windows command interpreter, execute either command.com or cmd.exe, depending on the Windows operating system you use. Listing 4.5 runs a copy of the Windows command interpreter and then executes the user-supplied command (e.g., dir).
    Taken from:
    http://www.javaworld.com/javaworld/jw-12-2000/jw-1229-traps.html

  • Need Info on Time Confirmation using IW41/IW42

    Hi PM Exterts.,
    Time confirmation of Operations is being done through IW41/IW42 by customer.
    The customer enters the 'Actual Hrs' & 'Work ends on' date and the 'Work Start on' date/time is calculated based on this.
    While listing the confirmations (from IW47), there are quite a few entries where the 'Work Start on' time is default (say 08:00:00).
    What are the possibilities for this error (or) wrong calculation...? I tried to replicate the issue in QA, but it is working perfectly...
    Kindly suggest.

    Have you checked the config on execution of control parameters in IMG ? Does you dates and time are dfaulting in IW41 ?
    Normally it should show up the same dates in IW47 as well.
    Check the ocnfig and tables.
    Mahee

  • HTTP Error 405 - The HTTP verb used to access this page is not .....

    Goodmorning,
    I've installed BO XI R3 SP4 on a 2k3-server with IIS 6.0. I wanted to configurate the SSO. After changing the web.config file and restart of the IIS , I get the following error :
    HTTP Error 405 - The HTTP verb used to access this page is not allowed.
    Internet Information Services (IIS)
    The frame where you normally are using for authentication has this error, the frame around is normal.
    Hope someony can help, thx in advance

    I can't fin a upload button , so the file in plain text gepasted
    Hope it is readable :
    #Software: Microsoft Internet Information Services 6.0
    #Version: 1.0
    #Date: 2012-02-29 12:19:21
    #Fields: date time s-sitename s-ip cs-method cs-uri-stem cs-uri-query s-port cs-username c-ip cs(User-Agent) sc-status sc-substatus sc-win32-status
    2012-02-29 12:19:21 W3SVC1 10.13.0.119 GET /InfoViewApp/logon.aspx - 80 - 10.13.0.119 Mozilla/4.0(compatible;MSIE7.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:19:21 W3SVC1 10.13.0.119 GET /InfoViewApp/res/schema.blue/default.css.ashx - 80 - 10.13.0.119 Mozilla/4.0(compatible;MSIE7.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:19:21 W3SVC1 10.13.0.119 GET /InfoViewApp/js/utils.js.ashx - 80 - 10.13.0.119 Mozilla/4.0(compatible;MSIE7.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:19:21 W3SVC1 10.13.0.119 GET /InfoViewApp/js/helpSystem.js.ashx - 80 - 10.13.0.119 Mozilla/4.0(compatible;MSIE7.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:19:21 W3SVC1 10.13.0.119 GET /InfoViewApp/common/appService.aspx service=skinning&resource=img&img=img.banner.logon.pattern 80 - 10.13.0.119 Mozilla/4.0(compatible;MSIE7.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:19:21 W3SVC1 10.13.0.119 GET /InfoViewApp/listing/blank.aspx - 80 - 10.13.0.119 Mozilla/4.0(compatible;MSIE7.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:19:21 W3SVC1 10.13.0.119 GET /InfoViewApp/common/appService.aspx service=skinning&resource=img&img=img.banner.logo 80 - 10.13.0.119 Mozilla/4.0(compatible;MSIE7.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:19:21 W3SVC1 10.13.0.119 GET /InfoViewApp/logon/logon.aspx parameter=logonService 80 - 10.13.0.119 Mozilla/4.0(compatible;MSIE7.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:19:21 W3SVC1 10.13.0.119 POST /PlatformServices/Shared/Logon/Logon.aspx - 80 - 10.13.0.119 Mozilla/4.0(compatible;MSIE7.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 405 0 1
    2012-02-29 12:32:05 W3SVC1 127.0.0.1 GET /InfoViewApp/logon.aspx - 80 - 127.0.0.1 Mozilla/4.0(compatible;MSIE8.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:32:05 W3SVC1 127.0.0.1 GET /InfoViewApp/res/schema.blue/default.css.ashx - 80 - 127.0.0.1 Mozilla/4.0(compatible;MSIE8.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:32:05 W3SVC1 127.0.0.1 GET /InfoViewApp/js/utils.js.ashx - 80 - 127.0.0.1 Mozilla/4.0(compatible;MSIE8.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:32:05 W3SVC1 127.0.0.1 GET /InfoViewApp/js/helpSystem.js.ashx - 80 - 127.0.0.1 Mozilla/4.0(compatible;MSIE8.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:32:05 W3SVC1 127.0.0.1 GET /InfoViewApp/listing/blank.aspx - 80 - 127.0.0.1 Mozilla/4.0(compatible;MSIE8.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:32:05 W3SVC1 127.0.0.1 GET /InfoViewApp/common/appService.aspx service=skinning&resource=img&img=img.banner.logon.pattern 80 - 127.0.0.1 Mozilla/4.0(compatible;MSIE8.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:32:05 W3SVC1 127.0.0.1 GET /InfoViewApp/common/appService.aspx service=skinning&resource=img&img=img.banner.logo 80 - 127.0.0.1 Mozilla/4.0(compatible;MSIE8.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:32:05 W3SVC1 127.0.0.1 GET /InfoViewApp/logon/logon.aspx parameter=logonService 80 - 127.0.0.1 Mozilla/4.0(compatible;MSIE8.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 200 0 0
    2012-02-29 12:32:05 W3SVC1 127.0.0.1 POST /PlatformServices/Shared/Logon/Logon.aspx - 80 - 127.0.0.1 Mozilla/4.0(compatible;MSIE8.0;WindowsNT5.2;Trident/4.0;.NETCLR1.1.4322;.NETCLR2.0.50727;.NETCLR3.0.4506.2152;.NETCLR+3.5.30729) 405 0 1
    2012-02-29 12:33:17 W3SVC1 10.13.0.119 OPTIONS /c$ - 80 - 10.13.8.13 Microsoft-WebDAV-MiniRedir/6.1.7601 200 0 0
    2012-02-29 12:33:17 W3SVC1 10.13.0.119 PROPFIND /c$ - 80 - 10.13.8.13 Microsoft-WebDAV-MiniRedir/6.1.7601 501 0 0
    2012-02-29 12:33:17 W3SVC1 10.13.0.119 PROPFIND /c$ - 80 - 10.13.8.13 Microsoft-WebDAV-MiniRedir/6.1.7601 501 0 0
    2012-02-29 12:33:17 W3SVC1 10.13.0.119 PROPFIND /c$ - 80 - 10.13.8.13 Microsoft-WebDAV-MiniRedir/6.1.7601 501 0 0
    2012-02-29 12:33:17 W3SVC1 10.13.0.119 PROPFIND /c$ - 80 - 10.13.8.13 Microsoft-WebDAV-MiniRedir/6.1.7601 501 0 0
    Thx in advance for your reply

  • Validation error message in a confirmation box.

    To provide any validation error messages i am using the throw OAException, but that displays at the top of the page where many times users dont even notice it. i want to be able to instead display the error msg in a confirmation box that has just the OK button to make sure user has seen the message......
    how do i do that ? (i do not want to use the DialogPage becos that takes me to another page and also is not for raising exceptions).
    thank you.

    Hi,
    You have to use OADailogue region to achieve this. Please follow below code units to create a dialogue page and display an error message.
    OADialogPage dialogPage = new OADialogPage(OAException.WARNING, message, null, "", "");
    String yes = pageContext.getMessage("AK", "FWK_TBX_T_YES", null);
    String no = pageContext.getMessage("AK", "FWK_TBX_T_NO", null);
    dialogPage.setOkButtonItemName("DeleteYesButton");
    dialogPage.setNoButtonItemName("DeleteNoButton");
    dialogPage.setOkButtonToPost(true);
    dialogPage.setNoButtonToPost(true);
    dialogPage.setRetainAMValue(true);
    dialogPage.setPostToCallingPage(true);
    dialogPage.setOkButtonLabel(yes);
    dialogPage.setNoButtonLabel(no);
    java.util.Hashtable formParams = new java.util.Hashtable(1);
    formParams.put("foo","value");
    dialogPage.setFormParameters(formParams);
    pageContext.redirectToDialogPage(dialogPage);
    Thanks
    Bharat

  • Error while creating resource group using non-globalzones.

    Dear all,
    Hi techs please guide me how to create failover resource group in nongloablzones.
    I'm getting error while creating resource group using non-globalzones.
    My setup:
    I have two node cluster running sun cluster 3.2 configured and running properly.
    node1: sun5
    nide2: sun8
    I have create non-globalzone "zone1" in node:sun5
    I have create non-globalzone "zone2" in node:sun8
    node:sun5# clrg create -n sun5:zone1,sun8:zone2 zonerg
    *(C160082) WARNING: one or more zones in the node list have never been fully booted in the cluster mode,verify that correct zone name was entered.*
    kindly guide me how to create Apache resource group using non-glabalzones, i'm new to sun cluster 3.2. please guide me step by step information.
    Thanks in advance,
    veera
    Edited by: veeraa on Dec 19, 2008 1:54 AM

    Hi Veera,
    Actually you are getting a warning message where one of two things could have happened. Either you specified an incorrect zone name or one of the zones has not been fully booted. It's likely that you haven't booted the zones, so please follow this:
    zoneadm list -iv
    If zone1 or zone2 are not running then boot and configure them
    zoneadm -z <zone> boot
    zlogin -C <zone>
    After that you can continue to follow the step by step instructions at
    http://docs.sun.com/app/docs/doc/819-2975/chddadaa?a=view
    These may also help
    http://blogs.sun.com/Jacky/entry/a_simple_expample_about_how
    http://blogs.sun.com/SC/en_US/entry/sun_cluster_and_solaris_zones
    Regards
    Neil

Maybe you are looking for

  • Can not save PDF as Postscript

    After installing Acrobat 8 on a MAC Pro Intel OSX 10.4.10 I can not use the Print dialog and selecting PDF Save as Postscript. I keep geting the message, Saving A PDF when printing is not supported. This does not occur on a MAC G5 running OSX 10.4.10

  • All of my music are frozen and I can't access it. How do I fix this?

    I cannot access any of my music or movies. I had my ipod touch linked to itunes trying to edit my music, then it started to update and after just my music and movies weren't accessible. Everything else works and my music and movies weren't deleted. I

  • Two Cuda gpu's non sli in photoshop

    Ok I finally just build another computer. In building I found out my old 8800gt card was not the culprate of an earilier problem so it actually usable!  I currently have gts250 installed...I know I know it was sidegrade not neccisarly much of an upgr

  • Generate report to view mailbox folder statistics

    hi, can someone advise how I run and save a report to a txt file to show the number of mails  in each inbox of every mailbox on the exchange 2007 server? `joe prior

  • Sudden Onset Image Thumbnail Issue

    I seem to be having some issue with image files. Since this morning, images tend to be a little corrupted, and I've been noticing that choose the "get info" tab, the thumbnails in the upper left corner are missing. Looks like this: http://i44.tinypic