GPIB and DAQ card access from JSDK 1.4.2

Dear Friends,
I have done many projects (by jsdk-1.4.2) of data acquisition and control with serial ports (COM-1 and COM-2) by RS-232C method.
But is it possible to access the GPIB card or Data Acquisition card of National Instruments (USA) for control and exchange data with some external instrument?
Can any body suggest anything ?
With best regards,
Avijit Das

You could use JVM 1.3.X because it uses SSL from the Internet Explorer, not the JSSE SSL.
Apart of this, you could see if the implementation of PKCS#11 for the forthcoming J2SDK 1.5 works with your card AND if JSSE can use the PKCS#11 Sun Provider. Download the beta and try it.

Similar Messages

  • How to synchronize the data acquisition from both GPIB and DAQ card

    I want to begin/stop acquiring the data from GPIB and PCI6024E card into Labview at the same time. Since the acquisition from GPIB is quite slow comparing to the one from DAQ card, I can not put both of them in the same loop structure. Is it possible to synchronize them?
    Thank you!

    Hi,
    I wanted to save data acquired from NI-DAQ (for example, NI 9234) in a file using the DAQ-mx ANSI C Code. The response I got was as follows:-
    One way to do it is with TDMS logging. DAQmx comes with functions designed to log to a TDMS file. This is a special file type that is used for collecting data in a logical format. It can be displayed in a TDMS viewer where data is separated into groups and channels. NI-DAQmx provides examples for how to log to TDMS. Look at the TDMS examples in the C:\Users\Public\Documents\National Instruments\NI-DAQ\Examples\DAQmx ANSI C\Analog In\Measure Voltage directory.
    However, now I want to know is there a way that using that same C code, can we save the data in a .txt file format (Text File) instead of a TDMS file? We actually want to access that file through MATLAB (that's why we want to save it in text format).
    Also on an other note, is there a way we can access & open TDMS files by MATLAB?
    Thanks,
    Sauvik Das Gupta

  • FPGA and DAQ card synchroniz​ation

    Hi, we are controlling and acquiring data from multiple hardware devices (including translational stages and photodetectors). Until last week, we used to peform all control and acquisition using a PCIe 7852R FPGA board. However, we decided to switch the acquisition part to a PCIe 6363 DAQ card to improve the voltage resolution. During testing, I found that the internal clocks in the FPGA and the DAQ cards are slightly mismatched (not just a phase delay, but a difference in time-period).
    I know this because I generated a square wave (period = 20us) using the FPGA and acquired it using the DAQ card (at a rate of 200kHz, i.e., 1 sample every 5us). I observed that the acquired square shifts by 5us every 5 seconds or so. Such a shift does not occur if the generation and acquisition is done using the same board. Therefore, the only explanation is that the clock frequencies of FPGA and DAQ cards differ. According to my calculation, percentage difference between their clock times must be 5us/5s = 0.0001%. 
    Therefore, I am wondering if there is anyway to synchronise the clocks between them. Or, is there a way I can drive the DAQ device based on the FPGA clock, or vice versa? Also, please let me know if there is something trivial that I have fix.
    Thank you very much.
    Regards,
    Varun
    Solved!
    Go to Solution.

    Hi GerdW,
    Thank you for your reply. 
    I understand both solutions you have suggested. I had conceptually thought about the first one (to control the sampling rate). However, I still haven't figured out how to accurately generate a 200kHz square wave - I think I can figure that one out this morning.
    However, I am unsure how to implement the second option. I presume the default internal clock inside the DAQ is running at 100MHz or so. Therefore, inorder to obtain the same performance while using an external clock, I would have to generate at least a 80MHz TTL clock-out from the FPGA. Could you please tell me how I can do that? I couldn't find any clock-out capabilities on my FPGA. Or would I have to generate a clock of my own using Single-Cycle-Timed-Loops?
    Not only did you provide two different solutions, your reply suggested that I wasn't wrong in interpreting that the clock periods of our FPGA and DAQ must be slightly off. 
    Thank you very much.
    Regards,
    Varun

  • SQL Server reporting server 2005 having error. 'The report server is not responding. Verify that report server is running and can be accessed from this computer'

    Hi team,
    I got below error message in SQL Server 2005 reporting service.
    ''The report server is not responding. Verify that report server is running and can be accessed from this computer'
    also in reports, i am getting below error:
    "The encrypted value for the "LogonCred" configuration setting cannot be decrypted. (rsFailedToDecryptConfigInformation)
    Get Online Help
    The report server has encountered a configuration error. See the report server log files for more information. (rsServerConfigurationError)
    Get Online Help "
    Please find below log:
    <Header>
      <Product>Microsoft SQL Server Reporting Services Version 9.00.4060.00</Product>
      <Locale>en-US</Locale>
      <TimeZone>Eastern Daylight Time</TimeZone>
      <Path>F:\Program Files\Microsoft SQL Server\MSSQL.6\Reporting Services\LogFiles\ReportServer__07_28_2014_09_08_41.log</Path>
      <SystemName>MFLDDDBS04</SystemName>
      <OSName>Microsoft Windows NT 5.2.3790 Service Pack 2</OSName>
      <OSVersion>5.2.3790.131072</OSVersion>
    </Header>
    w3wp!webserver!1!7/28/2014-09:08:41:: i INFO: Reporting Web Server started
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing ConnectionType to '1'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing IsSchedulingService to 'True'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing IsNotificationService to 'True'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing IsEventService to 'True'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing PollingInterval to '10' second(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing WindowsServiceUseFileShareStorage to 'False'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing MemoryLimit to '60' percent as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing RecycleTime to '720' minute(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing MaximumMemoryLimit to '80' percent as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing MaxAppDomainUnloadTime to '30' minute(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing MaxQueueThreads to '0' thread(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:41:: i INFO: Initializing IsWebServiceEnabled to 'True'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing MaxActiveReqForOneUser to '20' requests(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing MaxScheduleWait to '5' second(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing DatabaseQueryTimeout to '120' second(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing ProcessRecycleOptions to '0'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing RunningRequestsScavengerCycle to '60' second(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing RunningRequestsDbCycle to '60' second(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing RunningRequestsAge to '30' second(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing CleanupCycleMinutes to '10' minute(s) as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing DailyCleanupMinuteOfDay to default value of '120' minutes since midnight because it was not specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing WatsonFlags to '1064'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing WatsonDumpOnExceptions to 'Microsoft.ReportingServices.Diagnostics.Utilities.InternalCatalogException,Microsoft.ReportingServices.Modeling.InternalModelingException'  as specified in Configuration
    file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing WatsonDumpExcludeIfContainsExceptions to 'System.Data.SqlClient.SqlException,System.Threading.ThreadAbortException'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing SecureConnectionLevel to '0'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing DisplayErrorLink to 'True'  as specified in Configuration file.
    w3wp!library!1!7/28/2014-09:08:42:: i INFO: Initializing WebServiceUseFileShareStorage to 'False'  as specified in Configuration file.
    w3wp!resourceutilities!1!7/28/2014-09:08:42:: i INFO: Reporting Services starting SKU: Enterprise
    w3wp!resourceutilities!1!7/28/2014-09:08:42:: i INFO: Evaluation copy: 0 days left
    w3wp!library!1!7/28/2014-09:08:42:: e ERROR: Throwing Microsoft.ReportingServices.Diagnostics.Utilities.ServerConfigurationErrorException: The report server has encountered a configuration error. See the report server log files for more information., CryptUnprotectData:
    Win32 error:13;
     Info: Microsoft.ReportingServices.Diagnostics.Utilities.ServerConfigurationErrorException: The report server has encountered a configuration error. See the report server log files for more information.
    w3wp!library!1!7/28/2014-09:08:42:: e ERROR: Throwing Microsoft.ReportingServices.Diagnostics.Utilities.FailedToDecryptConfigInformationException: The encrypted value for the "LogonCred" configuration setting cannot be decrypted., ;
     Info: Microsoft.ReportingServices.Diagnostics.Utilities.FailedToDecryptConfigInformationException: The encrypted value for the "LogonCred" configuration setting cannot be decrypted. ---> Microsoft.ReportingServices.Diagnostics.Utilities.ServerConfigurationErrorException:
    The report server has encountered a configuration error. See the report server log files for more information.
       at Microsoft.ReportingServices.Diagnostics.DataProtectionLocal.UnprotectData(Byte[] data, Int32 dwFlags, Boolean transitoryData)
       at Microsoft.ReportingServices.Diagnostics.DataProtectionLocal.LocalUnprotectData(String data, Boolean transitoryData)
       at Microsoft.ReportingServices.Diagnostics.RSConfiguration.DecryptCatalogData(String encryptedData, String element)
       --- End of inner exception stack trace ---

    Hi Vivek,
    In Reporting Services, values for LogonUser, LogonDomain, and LogonCred are created when the report server connection is configured to use a domain account. As to the error that “The encrypted value for the "LogonCred" configuration setting cannot be decrypted”,
    we can know that it relates to the domain account for report server connection.
    To fix this issue, we can refer to the following steps:
    Log in to SQL Server Database Engine in SQL Server Management Studio.
    Under Security folder, give sufficient permissions for your domain account.
    Open your Reporting Services Configuration (go to Start -> All Programs -> Microsoft SQL Server 2005 -> Configuration Tools -> Reporting Services Configuration)
    Navigate to the Database Setup tab, select ‘Service Credentials’ as the Credentials Type, then type your domain account and password in there. Press Apply.
    Restart the Report Server services.
    Reference:
    http://social.msdn.microsoft.com/Forums/sqlserver/en-US/2d05b404-83aa-4fb2-bba6-52b587e890ec/sql-2005-rs-configuration-tool-encryption-key-error
    Hope this helps.
    Thanks,
    Katherine Xiong
    Katherine Xiong
    TechNet Community Support

  • Broblem with property node and DAQ-card

    Hi!
    I am using NI DAQ-card to control mini relays and I have a following broblem. I use a "binary" button to control the DAQ-assistant and so on the relays. I have made property node of the "binary" button and set it to value mode(write). When I change the value of property node, the "binary" button in user interface works properly, but the the relay doesn't change the state.

    The boolean array constant that you are writing to the property node is empty. That is it has been defined as a boolean array, but it has no elements.
    The array constant on the left is an empty boolean array. Notice that all teh boolean constants are grayed out. This indicates that none of the constants are 'active'. The array on the right contains 8 active elements. Note that the 8 elemants are more solid in color adn the the 9th element is grayed out.
    What you need to do is define your boolean array with the proper constants to turn on or off the proper digital lines.
    EdMessage Edited by Ed Dickens on 05-25-2005 09:15 AM
    Ed Dickens - Certified LabVIEW Architect - DISTek Integration, Inc. - NI Certified Alliance Partner
    Using the Abort button to stop your VI is like using a tree to stop your car. It works, but there may be consequences.
    Attachments:
    emptyarrays.png ‏2 KB

  • Delphi and DAQ Card

    Hi,
    for a particular project I'm working on, I'm using a National
    Instruments LAB-PC-1200AI card. The thing is, I have to be using Delphi as a
    programing language rather than LabView which makes things rather tricky.
    Does anyone know how I can access the card (in particular use the digital
    I/O lines) with this language? Are there any libraries/function libraries
    that can be accessed through Delphi or even C++ ? What about the Nidaq
    drivers, are they DLL files that contain functions that I can access through
    Delphi?
    Thankful of any feedback,
    Duncan Rumbold

    You could also use National Instruments ComponentWorks. They are a suite of
    32 bit ActiveX controls complete with controls for UI, Acqusition and
    Analysis. They also come with examples for VB, VC and Delphi. Download an
    evaluation version at http://www.natinst.com/cworks/cw_eval.htm
    Greg McKaskle wrote in message
    news:[email protected]..
    > ...
    > What about the Nidaq
    > > drivers, are they DLL files that contain functions that I can access
    through
    > > Delphi?
    > >
    >
    > You should have the CD that came with the DAQ board. If not, you can
    > download the driver from the NI ftp site. I believe that it comes
    > with Delphi examples, and yes, the NIDAQ drivers are a DLL and a DLL
    > interface.
    >
    > Greg McKaskle

  • Is there any difference b/w Crystal reports accessed from Crystal reports XI R2 and Crystal reports accessed from BO Eneterprise Crystal Reports Explorer

    Post Author: Sriramkusumanchi
    CA Forum: Crystal Reports
    Hi All,
    We are using BO XI R2 version.
    1. Under this version, the BO Enterprise product consists of Crystal Reports Explorer feature through which we can develop the crystal reports.
    2. And under the same version, the Crystal Reports XI R2 product consists of Crystal Reports feature through which we can develop crystal reports.
    I want to know, wheher there is any difference in the features for developing crystal reports through point 1 and point 2. If yes, then which product is the better option to go for Crystal reports development. (please note: I want the all the scheduling, automatic printing, printing on pre printed forms, etc features to be supported)
    Please help us to solve this confusion ASAP.

    Hi Nancy,
    The server info still needs to be updated. Are you setting location for each subreport also?
    Possibly this registry key will help, I only have CR 2008 installed so you'll have adjust for what ever you are using:
    HKEY_CURRENT_USER\Software\Business Objects\Suite 12.0\Crystal Reports\DatabaseOptions - VerifyStoredProceduresOnFirstRefresh = No
    and
    VerifyStoredProceduresOnSetLocation = No
    And
    VerifyWhenDBDriverUpgraded = No
    And
    ViewOutOfPlaceSubreports = No
    Close CR designer before making any changes. And the usual warning about modifying the registry.
    Thank you
    Don

  • How to monitor DAQ card outputs during TestStand operation?

    I am trying to debug a rare failure mode on a test station that runs on TestStand. TestStand controls measurement equipment through a PCI-GPIB controller and a DUT and DUT switch box through two NI-DAQmx devices; PCI-6509, and PCI-6534. I believe that root cause of the failure is due to the software not putting the DUT into the correct state for the test. In order to check this I need to monitor the changes on the GPIB and DAQ cards. I was able to use NI Spy to monitor the commands on the GPIB bus but I have not been able to monitor the state of DAQ cards. Is there a tool that will allow me to pause TestStand during its operation and look at what logic states the PCI-6509 and PCI-6534 outputs are in? Or at least monitor the I/O of the PCI-6509 and PCI-6534 cards similar to what NI SPY offers for the GPIB cards?
    Regards,
    David

    I am not aware of a tool similar to NI SPY for I/O cards.
    However you can introduce a break point at the point of interest in a test sequence(step).TestStand will stop execution at that point.
    You can then manually verify the I/O status using a DMM .
    Hope this helps.

  • Mac and Windows internet access

    Hi
    I've got my MacBook configured to startup in Windows XP or Mac OS X. Mostly I use Mac (of course) which is where I access the internet. But I have a need to access the internet via the Windows side and it won't. I have tried the Wizard but to no avail. Has anybody any suggestions of what I need to do.
    Wendy

    Apple Setup.exe
    XP is bad on security so it may try to run automatically.
    HOW TO and more is in the Boot Camp FAQ and PDF guide (access from Boot Camp Assistant as well)
    http://www.apple.com/support/bootcamp/
    Your Mac OS X DVD has a Windows /BootCamp volume that only shows up when in Windows. You can copy that to your XP system as well and run from there.

  • Trying change my credit card info from previously lost credit card but can't since it says I'm accessing from new device and asks for security code for a card i no longer have. What can I do?

    I've recently gotten a new laptop and replaced my damaged iphone. Apparently these 2 scenarios qualify as "new devices". This is fine but I also had lost my credit card previously that was connected to my iTunes account, and got a new one with all different numbers. When I try to change my billing information to this new card it won't let me because it says
    "Your account has been accessed from a new device, and you must verify your payment information before you can make purchases."
    and it asks for the security code of the card I had lost and replaced! I am not able to change my billing info to my new card thus because I can't get past this.
    Can anyone please help?

    Contact iTunes Customer Service and request assistance
    Apple  Support  iTunes Store  Contact Us

  • Data-acquisition with NI 6036E DAQ card & GPIB using an external trigger

    Hi all,
    I hope somebody could give me some help with the following and answer some questions:
    Simple system description:
    Labview 6.1
    PCI-GPIB card
    6036E DAQ card
    In my system, I am using an external analog trigger signal (A) for continuous data-acquisition. Characteristics of the analog trigger signal (A) are: ~40 Hz, signal height +1.48V, triggered by rising edge (the analog trigger signal (A) could be changed to a TTL signal). Each data-acquisition is done within ~1.0 ms after the rising edge of the trigger pulse. The timing of the data-acquisition and analyzing procedure is controlled by execution in a sequence structure placed in a loop.
    Now, I connected a power meter to the system, to measure the laser power during the data-acquisition. The power meter has two options to provide the laser power data:
    a) via analog signal output (voltage corresponds to laser power in watts)
    b) via GPIB (direct output reading of laser power in watts).
    Problem:
    During a certain point in my data-acquisition sequence structure (defined by a frame), I want to use the next occuring analog trigger signal (A) to acquire 1 value from the power meter.
    How do I do this in Labview programming for the following two situations?
    a) If I connect the analog output from the power meter to an analog input channel of the 6036E DAQ card. The analog trigger (A) would be connected to a second analog input channel (In case the analog trigger signal (A) is changed to a TTL signal it would be connected to the PFI0/Trig input pin on the DAQ card).
    b) If I use the GPIB connection of the power meter. The analog trigger (A) would be connected to a second analog input channel (In case the analog trigger signal (A) is changed to a TTL signal it would be connected to the PFI0/Trig input pin on the DAQ card).
    An other possibility would be to trigger the power meter directly, so it outputs constantly power meter values at ~40 Hz. How could I than acquire 1 power meter value (at a certain time im my sequence structure) via analog input at DAQ card or GPIB?
    Additional questions:
    How do I configure the PFI0/Trig pin on the 6036E DAQ board individually as an INPUT?
    How do I use an analog trigger signal (A) as counting signal for a loop, or as an activation signal for a sequence structure which includes GPIB commands?
    It would be very nice if somebody could give me some help.
    Kind regards,
    beam

    Hi beam,
    I just want to verify that I understand your situation correctly:
    An external trigger signal (A) is wired to one of your input channels (e.g. CH0) to trigger data acquisition of a second channel (e.g. CH1). Your power meter is connected to an analog input channel, which you would like to trigger with a certain rising edge at some of your sequence structure.
    Problem:
    During a certain point in my data-acquisition sequence structure (defined by a frame), I want to use the next occuring analog trigger signal (A) to acquire 1 value from the power meter.
    How do I do this in Labview programming for the following two situations?
    a) If I connect the analog output from the power meter to an analog input channel of the 6036E DAQ card. The analog trigger (A) would be connected to a second analog input channel (In case the analog trigger signal (A) is changed to a TTL signal it would be connected to the PFI0/Trig input pin on the DAQ card).
    If a task has been configured to acquire signal from one analog channel, it's not possible to run a second analog input task or to add a second channel on the fly. You had mentioned that it's possible to read from the instrument through GPIB. Is it possible to perform a software trigger such that at a certain frame of your structure, when the trigger signal A reaches voltage "x", a GPIB command is written to your power meter to query a measurement reading?
    Additional questions:
    How do I configure the PFI0/Trig pin on the 6036E DAQ board individually as an INPUT?
    You do not need to explicitly configure the PFI0 line as an input. If you want to use it as an input such that it acts as an analog trigger, simply wire the trigger signal to this pin. When configuring the trigger in your software, specify PFI0 as the trigger source.
    How do I use an analog trigger signal (A) as counting signal for a loop, or as an activation signal for a sequence structure which includes GPIB commands?
    You can try using the Limit VI to find out when the trigger signal reaches a certain level, and count how many times this level is reached. Similarly, you can use this as the condition to execute GPIB commands.
    Hope this helps,
    Lesley

  • How can I use a GPIB and AT-MIO-16L with a common NI-DAQ?

    I'm using a GPIB card for recording data and a AT-MIO-16L for sending an analog output to my instrument. Earlier, both the devices (GPIB and AT-MIO-16L) were running correctly. Until I reformated my hard disk. Now I'm trying to install NI-DAQ 6.1.1 for AT-MIO-16L but that doesn't detect my GPIB card. On the other hand if I use NI 488.2 along with MAX 1.7 or MAX 2.2, I'm unable to use AT-MIO-16L. Is there a way I could get both my devices running on a common platform?

    NI-DAQ is not supposed to detect your GPIB and NI-488 software will not detect your daq board. When you installed MAX, was this from a LabVIEW driver install CD that also put a new version of NI-DAQ on your pc. Open MAX and check your currently installed versions of NI-DAQ and NI-488. They should both be listed. If you have a new version of NI-DAQ than 6.1, you can uninstall the newer version and install 6.1.

  • Accessing DAQ-Card 1200 in LabVIEW?

    I configured Daq-Card 1200 in MAX, set the input and output values and so on. How can I now access the card in LabVIEW. Should there be maid any additional configuring under LabVIEW since first time I set up in and out values in MAX there was a place I could set different values to different channels but this time the configuration window lacked many things it used to have.

    When you configure the device in MAX, MAX assigns Device Number to the DAQ Cards starting with 1.
    In labview you can open up DAQ example and run it by specifying correct device number and channel number from which you want to acquire data. You do not need special configuration in labview.
    Hope this helps
    A Rafiq
    National Instruments
    http://www.ni.com/ask

  • Read/acquire signal from remaining empty channels of NI9205 by modifying the vi of ATI Force/Torque Transducer which uses the first 6 channelsof DAQ card.

    Hello,
    I am using force/torque transducer by ATI Automation. It provides me with its own vi to measure and write the data of the 6 signals (3 axes Forces, 3 axes torques)
    Following is my Ni system: -
    cDAQ 9172 chassis: Slot 5 - NI 9401, Slot 6 - NI 9205, Slot 8 - NI 9237. (Excitation voltage to the sensor/transducer (0-5V) using 9237).
    I connect the 6 signals from the transducer cable to channels ai0,1,2,3,4,5 in NI 9205(differential). The vi uses a calibration 6*6 matrix to finally display the calibrated voltage data.
    Now, I wish to use the remaining availabe channels that empty in 9205, namely ai17, ai18, ai19 for other signal measurements.
    ai17 channel is connected to Hall sensor  that gives out a square waveform corresponding to the rotor rpm. ai18, ai19 is connected to rotor-motor power supply's voltage and current signal respectively.
    But I am not able to access these 17, 18,19 channels from ATI company's vi. The vi loads the complete DAQ card (9205), uses only first 6 channels, hence the array data wire consists of only 6 channels. I can split these into 6 individual signals only.
    If I use a separate DAQ task to read channels ai17,18,19, then I get the error that this channels are reserved for some other task. Please tell me how can I access all the remaining channels apart from the first 6.
    I am attaching the vi here.
    Steps to run the "MEASUREMENT main.vi" : -
    Load calibration file:-  FT8840.cal;
    Load DAQ card: NI 9205
    Load ctr0 of NI 9401 (I am using this counter for rpm measurement purpose, this is my addition to the actual vi) 
    Attachments:
    DAQ - Copy.zip ‏574 KB

    There's nothing I can do to help.  I don't have your hardware to be able to modify your code and to set it up to make sure it runs properly.  Most people on the forum probably don't either.  This is where you'll have to put your programming and LabVIEW skills to work to solve your problem and make it run the way you want to.  If you run into a specific problem and get stuck, then please post back.

  • I use labview 8.0 and i can not run daqmx driver for pcmcia 6062e daq card

    i use labview 8.0 on window xp .when i installed a PCMCIA daq card 6062E, i could not run daqmx driver.It is fine to see that the traditional version is working well.When i install daq card sometimes it is working well with traditional driver  but mostly i see error on reading an analog input from PCMCIA daq device.An error called 'base adress' occures .I use last version of driver that is daqmx 8.0.1. and i have installed this correctly but again i could not  see any signal on the test panel for daq-mx driver.I don't know what is the problem.Also when i install PCMCIA daq card Please reply this message.I need your helps.
    Thanks

    Hello,
    Thanks for your reply.I will try to answer your questions.
    I have checked the Device Mananger and I have seen that the device is detected by Windows  XP.  For another question the card shows up under both NI-DAQmx Devices and Traditional NI-DAQ (Legacy) Devices consistently in the Measurement & Automation Explorer.I use a way that I reset the driver for traditional NI-DAQ in MAX,and then i reset the device for NI-DAQmx driver in MAX and again i tried to run the test panel of DAQmx driver but again i saw a wrong signal or noise signal on the test panel i could not see the sinusoidal signal that i connected. i do get the test panels to run with the card using the DAQmx driver,  But could not run the DAQ diagnostic utility.The error was as i specified below.
    03.05.2006 09:49:35
    Results saved to:  C:\Documents and Settings\serkan\Desktop\Diagnostic Results.txt
    Selected Device: Dev1
    Device Type: DAQCard-6062E
    Serial Number: 107509E
    Device Support: (PASS)
    NI-DAQmx Version: 8.0 (PASS)
    Device Reset: (FAIL)
    Error -50002 occurred at an unidentified location
    Possible reason(s):
    The specified device is not a valid device. The operation could not be completed as specified.
     ------ DIAGNOSTIC UTILITY ABORTED -----
    And for your last question i can say that i have used the DAQ card on other laptops.But the results were the same.İ hope to see your reply
    Thanks,
    Serkan Buhan
    Electrical-Elecronics Engineer
    Researcher
    TUBITAK-BILTEN

Maybe you are looking for

  • Link on a report to Activity

    Hi, I would like to create a report based on appointments. I woudl like to have a link to open the record when user click on the subject or another field. I succeed to do it with opportunity but it doesn't work for activities. Can you correct my link

  • MS Outlook send/receive data file missing

    Whenever I open up MS Outlook 2007, I get an error message: "outlook cannot start because a data file to send and receive mail cannot be found. To add a data file, such as a person folder file, double-click the mail icon in windows control panel." I

  • How to create a DLL in CVI which can be used in MFC?

    I want to create a DLL in CVI and use the DLL in MFC. But even if I tried many ways, I cannot reach the objective. There are always link errors. Could you give me some instructions about it?

  • My ipod touch camera hasnt been opening and ive already restarted my ipod multiple times. Any tips please?!

    My ipod touch hasnt been open the camera even though ive restarted the ipod sooo many times. Does anyone have any ideas to share? Please and thank you!

  • Reflective access-list in a WS-C3560G-24TS

    I have a reflective access-list in a switch doesn't seem to work. What I want is allow our campus traffic (141.225.0.0/16) to flow freely, and block outside traffic come in except for certain users. Allow inside network (141.225.216.0/24) to go outsi