Help w/ lab connetion
setting up a lab again. here is what I have
2610 and 2501 rtrs
2912-xl and 2924-xl.. this may be a dump question. I am not able to ping from labsw2-2912 to other interfaces. am setting this lab wright or I am missing someting, the DCE and DTE connection interfaces seems to talkk to each other
CHK THE DRAWING
Hi,
You cannot ping R1 because there's no route back. On R1, configure a static route or dynamic routing protocol b/w R1 and R2
The easiest thing would be to add a static route on R1 to the 10.0.0.0 major network
ip route 10.0.0.0 0.255.255.255 [R2 serial interface ip address]
I also see that you have set up R1 and R2's serial interface ip address to 192.168.1.3. Please correct that as well. And according the diagram the default gateway on labSw2-2912-xl must be 10.0.0.3 [R1's e0/0 ip address]
HTH
Lejoe
Similar Messages
-
Decision help for lab / school
I have a small school. We are are all on 10.6.8. Classrooms, admin/teacher offices and a student Lab are the three primary groups within our org.
I currently only use general logons for students - via class. ie, Grade6 - all grade6 students log on at the same time with same logon. this works for most things, but not for some things. I want to move to individual logons for the students. but, I have to consider the rest of the network, and advantages and disadvantages of this...
Should I setup a second OD server just for the lab / students?
What are some advantages and disadvantes of putting the kids on the same OD as the the rest of the school / separating them?Here are some thoughts on that. Some advantages of a 2nd server would be to balance the workload between servers for AFP and other services. Criteria to consider here would be the number and types of services you have running on your servers. Another consideration would be your network infrastructure. I believe a single OS X server is capable of handling 175 simultaneously logged in users. How efficiently it can do this depends upon the type of work being done and how big the files that are being moved around might be. If your switching at gigabit throughout the network, with gig nics in most of the workstations, it should be fine. However YMMV. Another minor consideration woud be security for staff and admins. Good passwords for staff here should handle that consideration in your environment. If your single OD server is efficiently handling the load which you are putting it under now, I would think that there would be no need for a 2nd OD server.
-
I just bought "zen" yesterday online, and received it today, brand new, but when i power it up, all i see is a white screen, why? can someone provide me with a solution?
Thanks for that.... but still no help, i downloaded the file but wen it came to install at the end wen it says to connect mp3 to pc the software still does not recognise it yet the pc does n it wont continue n complete install?any other help pls?ps the firmware i have on my mp3 is 2..0 which is latest n i also have windows media player
-
Please Help: 3550 lab switch locked by radius server
Hi All,
Any idea? After clean up all routers and switches config files, sw3 still asks for radius username and password.
When console login and using 3550 password recovery procedure, it still asks for username and password.
When config aaa new-model, no username is asked only the passowrd cisco in typed in. (please see detail config file in the following)
Note: This is for CCIE R&S home lab rack.
==========
// radius server locks sw3
Access-Server#9
[Resuming connection 9 to sw3 ... ]
User Access Verification
Username:
Username: cisco
Password:
% Backup authentication
00:27:36: %RADIUS-4-RADIUS_DEAD: RADIUS server 150.100.1.254:1645,1646 is not responding.
00:27:36: %RADIUS-4-RADIUS_ALIVE: RADIUS server 150.100.1.254:1645,1646 has returned.
Username:
===========
sw3#sh run
Building configuration...
Current configuration : 4655 bytes
version 12.2
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
hostname sw3
aaa new-model
aaa authentication dot1x default group radius
aaa session-id common
mls qos
ip subnet-zero
ip routing
no ip domain-lookup
dot1x system-auth-control
dot1x guest-vlan supplicant
no file verify auto
interface FastEthernet0/11
switchport mode access
dot1x pae authenticator
dot1x port-control auto
dot1x guest-vlan 999
dot1x auth-fail vlan 999
interface FastEthernet0/12
switchport mode access
dot1x pae authenticator
dot1x port-control auto
dot1x guest-vlan 999
dot1x auth-fail vlan 999
interface FastEthernet0/13
switchport mode access
dot1x pae authenticator
dot1x port-control auto
dot1x guest-vlan 999
dot1x auth-fail vlan 999
interface FastEthernet0/14
switchport mode access
dot1x pae authenticator
dot1x port-control auto
dot1x guest-vlan 999
dot1x auth-fail vlan 999
interface FastEthernet0/15
switchport mode access
dot1x pae authenticator
dot1x port-control auto
dot1x guest-vlan 999
dot1x auth-fail vlan 999
interface FastEthernet0/16
switchport mode access
dot1x pae authenticator
dot1x port-control auto
dot1x guest-vlan 999
dot1x auth-fail vlan 999
interface FastEthernet0/17
switchport mode access
dot1x pae authenticator
dot1x port-control auto
dot1x guest-vlan 999
dot1x auth-fail vlan 999
interface FastEthernet0/18
switchport mode access
dot1x pae authenticator
dot1x port-control auto
dot1x guest-vlan 999
dot1x auth-fail vlan 999
interface FastEthernet0/19
switchport mode dynamic desirable
channel-group 1 mode desirable
interface FastEthernet0/20
switchport mode dynamic desirable
channel-group 1 mode desirable
interface FastEthernet0/21
switchport mode dynamic desirable
interface FastEthernet0/22
switchport mode dynamic desirable
interface FastEthernet0/23
switchport mode dynamic desirable
channel-group 2 mode desirable
interface FastEthernet0/24
switchport mode dynamic desirable
channel-group 2 mode desirable
interface GigabitEthernet0/1
switchport mode dynamic desirable
interface GigabitEthernet0/2
switchport mode dynamic desirable
interface Vlan1
no ip address
shutdown
ip classless
ip http server
ip http secure-server
radius-server host 150.100.1.254 auth-port 1645 acct-port 1646
radius-server source-ports 1645-1646
radius-server key ciscotry to do password recovery per cisco doc, but config.text file is missing from flash dir:
switch: dir flash:
Directory of flash:/
2 -rwx 5276 syslog
3 -rwx 0 env_vars
4 -rwx 7131928 c3550-ipservicesk9-mz.122-25.SEE.bin
5 drwx 64 crashinfo
24 -rwx 326 system_env_vars
7 drwx 192 c3550-i9q3l2-mz.121-13.EA1a
26 -rwx 24 private-config.text -
I want to get and set windows system time through lab view
Hi
I want to get and set windows system time with the help of lab view 8.5.
please help me out.
ekanthYou can use the call library function node. Once you drop it on your block diagram double click it and you will be able to select the dllyou want to use. Choose kernel32.dll and you will see methods listed called getsystemtime and setsystemtime. Use those
CLA, LabVIEW Versions 2010-2013 -
Looping through nested datasets
My apologies in advance if this has been asked before, but the search function on these forums doesn't appear to be working at the moment...
Using: Spry 1.6.1
Dreamweaver CS5
IE 7 and 8, Firefox 4, and Chrome 10
The question:
I have a parent xml dataset, with two nested datasets, like this:
var dsCourse = new Spry.Data.XMLDataSet("menu2.xml", "menu");
var dsTopic = new Spry.Data.NestedXMLDataSet(dsCourse, "topic");
var dsLessons = new Spry.Data.NestedXMLDataSet(dsTopic, "lesson");
The data displays properly in the html, using regions, etc. However, when I try looping through them using javascript:
topics = dsTopic.getData();
for (var t = 0; t < topics.length; t++) { //loop through the topics dataset
dsTopic.setCurrentRowNumber(t);
var top = dsTopic.getCurrentRow();
alert('current topic row name: ' + top["@name"]); //for debug purposes, display the topic name
var rows = dsLessons.getData();
for (var i = 0; i < rows.length; i++) { //loop through the lessons dataset
dsLessons.setCurrentRowNumber(i);
alert("lesson name is: " + rows[i]['name']);//display the lesson name
It will perform both loops properly, displaying the correct information for each dataset in Firefox 4, but in IE 7 and 8, and in Chrome it will list each of the Topics correctly, but only displays the first set of lessons.
The xml looks like:
<topic name="Claims" default="true" complete="false">
<lesson>
<name>Getting Started</name>
<score>0</score>
</lesson>
<lesson>
<name>Adding a Claim</name>
<score>0</score>
</lesson>
<lesson>
<name>Adding a Claimant</name>
<score>0</score>
</lesson>
<topic name="Bills" default="false" complete="false">
<lesson>
<name>Bill Components</name>
<score>0</score>
</lesson>
etc.
For what it's worth, all of the topics and lessons display properly in the html using spry regions, etc. It only appears to have an issue in javascript. And then only in IE. Is there, perhaps, a better way to do this that I'm not aware of?
Thanks in advance!
JonathanThis might help http://labs.adobe.com/technologies/spry/samples/data_region/NestedXMLDataSample.html
Gramps -
Adobe CS6 Applications not opening after installation via AAMEE
I setup AAMEE with the desired CS6 apps, disabled updates, installed the AAMEE package on the master image then deployed it out to several Mac labs. Most of the clients are fine but on some, when I try to open Photoshop or Illustrator, etc., the icon appears in the dock along with the Adobe Application Manager icon. Both icons appear and disappear simultaniously, and theres no way to force quit anything. Does anyone know how to fix this? Please help, the labs need to be CS6 ready by this Friday..
Here is the error log I get, and it keeps repeating:
"1/9/13 10:51:49.290 PM PDApp: CFURLCreateWithString was passed this invalid URL string: '/System/Library/Frameworks/' (a file system path instead of an URL string). The URL created will not work with most file URL functions. CFURLCreateWithFileSystemPath or CFURLCreateWithFileSystemPathRelativeToBase should be used instead."
Thanks!Yep.
Having the same problems here too. There does not seem to be any rhyme or reason for this either. First, this was happening only on a couple of my Macs, now it seems to be affecting over 50% of them on campus.
I am wondering if there was a bug in a recent Adobe CS6 update that I may have pushed out when using RUM.
Adobe. I need help and quick. We are due an Ofsted inspection soon and this does not look good at all. -
Spacing of Spry Menu submenu items, and inserting background images
Hiya, need a bit of help, could someone possibly guide me with this?
I've created a Spry Menu in DW CS5 - so far, so good.. However I'm pretty new to CSS Styles so need pointers at what to change to get the result I need. I've created the spry menu, however the submenu dropdown items are not flush to the ones above, theres a 1px horz gap between each item and while it looks okay, its particularly visible in Firefox and Chrome and would prefer no spacing at all..
The live site is at http://www.ebm.co.uk/2011site/indexnavbar2.html
if you take a look at the drop down menu bar you'll see what i mean - what do I need to do to remove the spacing?
I also want to replace the solid colour with images, where do I specify the images for 1) top menu item 2) submenu item and 3) 'hover' item, and do I need to make any areas transparent?
Any advice would be much appreciated.. thanks!
ChrisThis is a good place to start http://www.dwcourse.com/dreamweaver/ten-commandments-spry-menubars.php.
Also this might help http://labs.adobe.com/technologies/spry/samples/menubar/CenteringHorizontalMenuBarSample.h tml
Gramps -
Anybody know how to hide/display a panel. I want to be able
to hide certain panels/tabs with dynamic data.There is a lot of info about the Spry Widgets at the Adobe
website. See if
the first example here will help.
http://labs.adobe.com/technologies/spry/samples/tabbedpanels/tabbed_panel_sample.htm
Regards,
..Trent Pastrana
www.fourlevel.com
"parkingtech" <[email protected]> wrote in
message
news:fdsjan$cvl$[email protected]..
> Anybody know how to hide/display a panel. I want to be
able to hide
> certain panels/tabs with dynamic data. -
I downloaded the beata version of cs6 extended but I can't find any of the extended features like 3D
Hi Madsurfdog,
Are you able to view the 3D menu in CS6 beta or that option is greyed out?
This is how the menu bar looks like in my PS CS6 Beta.
Please go to the below link and download and install the latest build for CS6 beta and check if that helps.
http://labs.adobe.com/downloads/photoshopcs6.html
Regards
Arpit Kapoor -
Hi, I'm working in a website that must be 100% compatible with iPads. So I am wondering about the use of spry widgets and general javascript coding.
What is your experience in iPad oriented sites? What should I avoid in this webpages.
Any comment org suggestion will be appreciated.Hi
This may help - http://labs.thesedays.com/2010/07/16/10-tips-for-designing-mobile-websites/. Don't forget to read the comments as a few useful tips are included.
PZ -
Time to pass data to half buffer in a double buffer acquisition
Hello all:
I'm building a DAQ system with CVI 6.0 and an old Lab-pc+. I don't have access to the hardware at the moment and I was thinking how much time it will take to DaqDBTransfer function to pass 75750 points to the halfbuffer. Someone who know this?
Other question for the group:
Imagine that I'm programming this for acquiring with Lab_ISCAN_Start and timebase 1us with sample interval 33 which means 30303,030303 Hz (3 channels, or 10101,01010 Hz/chnl). I need to know if it's certain to say that point n acquired has happened exactly at n*3.3*10E-5 seconds. which is, for example, that point 80000 has been acquired at 2,64 s. from the beginning of the Scan. And how accurate is that.
thank y
ou all in advance.Hello Gonzalo,
Be aware that this depends on the number of channels in your scan list and where it is in the scan list. In the Lab_ISCAN_Start() function there are two numbers you are concerned with. The sampInterval and the sampTimbase. (And the scanInterval if you choose to use this.)
First, determine when the particular channel you are interested in is sampled. This depends on which channel it is in the scan list. The Nth channel will be sampled at N*(sampInterval*sampTimebase) seconds.
Then, your scan period. The scan period will either be the scanInterval, or (if scanInterval is 0, 1 / (number of channels * (sampTimebase * sampInterval)).
The Mth sample of channel N will be sampled at
M*(number of channels * (sampTimebase * sampInterval))
+ N*(sampInterval*sampTimebase)
You might also look at the NI-DAQ Function Reference Help for this function for more information. This is accurate to within the base clock specification in your boards user manual.
Also, how long will it take to pass 75750 points with DaqDBTransfer? You can get a good estimate by using the above formula. Then you can guess there will be a few us of software overhead for the actual transfer.
Also, here are a few links you might find helpful.
Lab-PC+ User Manual
http://digital.ni.com/manuals.nsf/webAdvsearch/53215E9F6E1D0EA78625665E006359B4?OpenDocument&vid=niwc&node=132100_US
NI-DAQ Function Reference Manual for PC Compatibles
http://digital.ni.com/manuals.nsf/webAdvsearch/1F23F2C8FB44D660862566960071D243?
OpenDocument&vid=niwc&node=132100_US
and this is a good one...
Data Acquisition Definitions: Scan Rate, Channel Rate, Sampling Rate, Scan List, Interchannel Delay
http://digital.ni.com/public.nsf/websearch/DBE7AC32661BCF9B86
256AC000682154?OpenDocument
Anyway, I hope this helps!
Russell
Applications Engineer
National Instruments
http://www.ni.com/support -
Colored lines in the highlights
Hello All,
As you can see I am getting these lines in the white highlights. Have no idea way.
Photoshop CS3, Camera Raw 4.6, Mac G4, OS 10.4.11
Will get same result from Nikon D70 and Nikon D90.
Used PS Elements several years ago without this issue.
Thanks
Donfunction(){return A.apply(null,[this].concat($A(arguments)))}
function(){return A.apply(null,[this].concat($A(arguments)))}Donald Pye wrote:
It shows exactly what you have shown, ACR 4.6. Exactly how many profiles are suppose to show up in that drop done menu?
As evidenced by the above, "supposed to show up" is a difficult thing to nail down. They can be downloaded and later versions of Photoshop bring more of them, which then show up in older versions.
My CS3 with ACR 4.6 shows this:
I take it from your question that you are not seeing any other profiles in there. I did download beta profiles at one time (evidenced by the "beta" nomenclature), but ACR 4.6 came with Photoshop. I'm thinking that on all our systems where it works okay an earlier, faulty profile may have been overwritten with a new, improved copy of the same name by a later version of Photoshop, however, as all these profile files go in the same place.
Something to try: Find copies (possibly on the Adobe Labs site) of newer Camera Raw profiles for your particular cameras and copy the files into /Library/Application Support/Adobe/CameraRaw/CameraProfiles/Camera on your Mac.
A link that may help: http://labs.adobe.com/wiki/index.php/DNG_Profiles:FAQ#WhereInstall
I don't know if it's legal to provide copies of these files, but if so I would gladly send them to you.
-Noel -
I have adobe reader 11 and it isnt working anymore
I have windows 7 and my adobe reader isnt working anymore now that I have upgraded to the latest version. It opens the PDF up and then times out and says there is a error and the program is closing! I have tried repairing it and uninstalling it and then reinstalling it several times.....and nothing works. Please help.
http://labs.adobe.com/downloads/acrobatcleaner.html
Try the Acrobat and Reader Cleaner tool, then reinstall. -
Can I get stepped out put voltage signal for controls from the BNC with Labview?
Hi!
I am new user to NI Labview. I am working in controls applied in Combustion sciences. I want control the Solenoid valve ( Jefferson made,230 V, 11 W) in stepped manner. BNC (2110) is used for the input signal (Piezoelectric pressure transducers) and output signal. The maximum out put voltage from BNC is 5 V. Can I get the out put voltage in stepped and increasing order to ensure the better controls of the solenoid valve?
Also I would like to know, is it possible for me to control the working frequency ( Injecting) of the solenoid valve with the help of Lab view?
Thanks.
With Regards,
GaneshJust having the same issue there, which is real not fun, I have not tried to contact them, but looking at your experience I am not sure if I should.
My key comes from the back of a laptop o so I guess that would be a W7
OEM, and that could explain why you can't download a ISO from their website, would that also your case ?
Also could it be because we are attempting to get the ISO after the product became EOL ?
http://windows.microsoft.com/en-us/windows/lifecycle
Maybe I will give a go with the customer care people and maybe I will get a right answer ;)
Will keep you posted
Maybe you are looking for
-
BI 7.0 Infoset - Infocube - Left outer join - query
Hi Expert, A infoset contain Infocube and ODS, linked with left outer join, common fields are PO,PO item. PO account assignment ODS have three keyfields: PO Doc.,Item,account Assignment . PO Infocube <b>PO
-
Ichat video on mac with AIM on PC
I'm using ichat to use my webcam but every time i try to start a web cam conversation with someone who is using the PC version of AIM it doesn't work from my ichat. I'm wondering if there is a fix for this?
-
My T40 display (lcd) suddenly turns blank, any help
My T40 display (lcd) suddenly turns blank, any help Mo Moderator Note; please update your profile with your correct country location as per the forum rules. Products, options and services vary from market to market. Knowing your location helps us hel
-
Photoshop Drag and Drop Broken
For some reason I can't drag and drop files on Photoshop CS4. Is this a known bug? Is there a workaround?
-