Hello All,
I am trying to build a RejectedMessageHandler process to send notification to administrator if any message has been rejected by Adapters.
I read this document.
http://www.oracle.com/technology/products/integration/adapters/pdf/Adapter_TN_004_Adapter_ErrorManagement.pdf
Then I downloaded the RejectionMessage.wsdl and JCAErrorHandling.xsd from SOA server. Then use the RejectedMessage in JCAErrorHandling.xsd as the input type for this Async RejectedMessageHandler process.
The add rejectedMessageHandlers information in bpel.xml of my Adapter test process to call the RejectedMessageHandler process.
<property name="rejectedMessageHandlers">
bpel://default|RejectedMessageHandler|initiate|RejectedMessage
</property>
The un-well formatted message will go to the defined directory, but no RejectedMessageHandler instnace has been created.
Any suggestion.
Regards,
Kerr
Hi Kerr,
<property name="rejectedMessageHandlers">
bpel://<bpel-domain[:<password>]>|<process-name>|<operation-name>|<input-message-part-name>
</property>
(<password> for domain if not "bpel" - can be encrypted - "[]" means optional)
for example
<property name="rejectedMessageHandlers">
bpel://default|JCA-RejectionHandler|handleRejection|message
</property>
This rejection handler will send the bad message to another (designated error handling) BPEL process. The user can thus define a process with a Receive operation of his own choosing (WSDL and BPEL src) - the only constraint is on the Message Type of the message that will be sent to this rejection handler. It must be declared to have the type "RejectedMessage". This can conveniently be achieved by importing the "xmllib" resident WSDL "RejectionMessage.wsdl" which defines such a message:
<message name="RejectionMessage">
<part name="message" element="err:RejectedMessage"/>
</message>
An xmllib WSDL import (from another WSDL) is achieved using the "well-known" URL
<import namespace="http://xmlns.oracle.com/pcbpel/rejectionHandler"
location="http://localhost:9700/orabpel/xmllib/jca/RejectionMessage.wsdl"/>
i.e. the Receive operation WSDL which the user defines for his Rejection Handler BPEL Process would simply contain this import and then the port type would reference this:
<definitions ...
xmlns:rej="http://xmlns.oracle.com/pcbpel/rejectionHandler"
<portType name="MyRejectionHandlerPortType">
<operation name="myHandleRejectionOperation">
<input message="rej:RejectionMessage"/>
</operation>
</portType>
WSIF Based Rejection Handler
<property name="rejectedMessageHandlers">
wsif://<wsif-wsdl-location>|<operation-name>|<input-message-part-name>
</property>
for example
<property name="rejectedMessageHandlers">
wsif://file:/C:/orabpel/samples/test/ErrorTest/FileAdapterWrite.wsdl|write|message
</property>
This last rejection handler lets the user configure any type of WSIF WSDL (JCA, EJB, JMS, HTTP, Java etc), i.e. any kind of Service which can be reached via WSIF - as the bad message handler. The exact same constraint vis-a-vis the Message Type as described above for the BPEL Process Rejection Handler also applies here.
You might want to use WSIF for the same as mentioned in : http://download-west.oracle.com/docs/cd/B31017_01/integrate.1013/b31005/life_cycle.htm#CIAGHAAD
Hope that helps!
Cheers
A
Similar Messages
-
How to build the FM data I_header and I_orgdata
hi all,
Im working on the conversion program for AVL using the following function modules
BBP_PD_AVL_GETLIST
BBP_PD_AVL_CREATE
BBP_PD_AVL_UPDATE
BBP_PD_AVL_SAVE
In the function module BBP_PD_AVL_CREATE , how to build the FM data I_HEADER and I_ORGDATA.
I'm giving 3 input in Export parameter in BBP_PD_AVL_GETLIST and E_pdlist should contain data .
but e_pdlist is not getting data...any suggestion..
after execution it was showing "Buffer table is not up to date"
with regards,
P.lokeshHi Lokesh,
We are also encountering same problem.
How did you solve your problem?
Would really appreciate your help.
Thanks,
Kezia -
How to stop the running process chain
How to stop the running process chains or infopackges...just qm status change is enought?
BI - SM 37 - Kill the Job
ECC - SM 50 - Kill the job -
How to stop the backup process....
How to stop the backup process....
Okay, so it happens nearly everytime you synch your iPhone with your iTunes? Easy. As soon as it starts, hit the "X" in the bar where the backup process is being shown, this does NOT STOP the synching process, ONLY the backup process.
HOWEVER, keep in mind that a few times during the week (depends how often you synch ur iPhone) it will be good to let the backup process let run fully.
There we go. Problem solved...i agree its what i do i backup whenever i add a new app, or take more pics etc its exactly what i do its what ive been saying on all these threads talking about backups etc, im hoping in 2.0.1 will be bug fixes about this sort of thing...
-
How to get the all process orders and outbound deliveries based on material
Hi Team ,
I need one help from you regarding the MB 56 transaction.
My doubt is : How to get the all process orders and outbound deliveries based on material, plant and batch?
Please help me regarding this.
Thanks & Regards,
Srikanth.Hi,
You can use ST05,to trace the program and find out,
hope it will help you...
thanks and regards,
veera. -
How to determine the Parent process information in Oracle BPMS 10g
Hi ,
I am trying to retrieve the parent process information given the instanceId and Process Id of an instance of a process from a different process.
I am getting the instanceId of the instance in workspace using the Fuego.Papi.ProcessService and by creating the Filter.
I tried using the ProcessInstance.parent but it needs to be instantiated using the instance details of my referred instance, which i am not able to do.
Can some one shed some light on how to get the parent process details from the referred instance.
Thanks,
shravan.Hi,
If you mean to increase the request timeout i.e the time when a request is submitted to the server and the response is sent by the server it can be done in httpd.conf file located in $OracleHome/Apache/Apache/conf directory.
The attribute to be used for setting timeout is "Timeout". By default teh value is 600 seconds i.e 5 minutes.
After making these changes , run command dcmctl updateConfig -ct OHS and restart the HTTP Server. Please note these commands need to be run only if the httpd.conf changes are done through text editor.
Hope this helps.
Smita -
How to restart the Successfully processed messages
Hi,
I have IDOC to File Scenario
we posted the idoc from R/3 and it has processed successfully.
Now again i want to process that idoc again with out going to R/3.
How to restart the Successfully processed message from MONI.
we have one option in MONI Restart. this is not working for Successfully processed messages.
How to achieve this
Regards
SumanHello Suman..
XI: Restarting successfully processed messages..
Go through this : Michal Krawczyk Blog This will really helpful to you..
/people/michal.krawczyk2/blog/2005/11/09/xi-restarting-successfully-processed-messages
Reward Points If it is Helpful...
Thanks,
Satya Kumar.. -
How to synchronise the job processing from the program.
How to synbchronize the job processing when we are creating jobs from the program.
Thanks,
Ramana.hi,
yes you can do this..
try this
create a two screen suppose 9000 and 9001..
then right click on your program name...
create a TCODE say TONE..
in this give the screen number 9000..
now again right click on the program name
create a TCODE say Tsecond
in this give the screen number 9001...
hope this will help you..
Regards
Ritesh J -
How to learn the Business Process and how it is related to BI?
Dear Experts,
How to learn the Business Process? for example the business process from finance to sales. As I am more involved in technical development of BI; I dont know or having very hard time to understand what the business process. And how the Business Process is related to BI?
I think if I don't understand the business process than it is very hard to satisfy the User requirements. If you have any documentation please feel free to forward it to [email protected]
I wish you happy new year. Thank you in advance.
Aslam.If only plan data entered, try to delete the planning data before delete the object and then re-create it again. Otherwise you may have to leave it as is and change the description for the usage by the different company code.
-
My designs are not showing, how long is the approval process
My designed personas are not showing, how long is the approval process
== This happened ==
Not sure how often
== Next day after uploadingA few days to a week, give or take.
-
How to write the Business Process
Can anybody please give me the link on How to write the Business Process for <b>IC_C03</b>... we have done the blue print and going to write the documentation for this info provider.
So please provide the related links..........Probably the best thing to do is go to your boss/team lead/project manager/client contact and ask them what documentation they want you to produce and what should go in it. No-one here can guess at that.
Gareth. -
How to simulate the escalation process
Hi All,
Can somebody tell me how to simulate the escalation process in service?I need to know whether all configuration in my system has done or not done yet....
In my system if there's a problem in customer system for more than 7 hour, then system will detect the problem and send an sms/email to the person responsible in some level (ex: level 1 for SLG 95%), if the customer system still have a problem for more than 10 hour, then system will send an sms to person responsible in level 2, etc.
I want to know how can I simulate this escalation process in CRM service manually. I'm using CRM 5.0. Any helpful answer will be rewarded. Thank you.
Rgds,
Aleluya sap.Hi Aleluya,
You can use date types which will have the times at which the trigger of mail is supposed to happen and once the current date and time is equal to say date type 1 there can be an action setup to send a mail to a particular partner function .
Also you can use status condition for controlling the mails ..
hope it helps
Cheers!
Raj -
How to check the parent process chain of a meta chain
Hello Friends,
Recently I joined a new project, which is of environment BW 3.0. I am trying to find the dependent process chain's parent, but could'nt able to find them. I went through all the process chains manually to check whther the dependent process chain is mentioned in them, but could'nt find any......
Can any of you help me to know how to find the parent process chain of a meta chain ?
I really appreciate your time, will be awarding points to any answers.......
Thanks,Hello Radhan,
thanks for your quick reply. I searched the table based on your advice, but i could'nt get the parent process chain's name. Can you throw some more ideas please..........
Thanks, -
How to continue the running process behind the model dialogue box options ?
How to continue the running process behind the model dialogue box options like this
In Updation of K7 user press the Cancel Button
New dialogue box appear with Yes/No options.
But the backend updation is going on... not Pause the updation.
Like this how to do ?
Please provide me code.I don't know, if you mean you have done your form or you have solved the problem.
It's visible your code is only partly reflecting your screenshot, and that's okay to demonstrate the problem you have given a fine example.
As you marked my suggestion as solution this may not be needed anymore, but here's how I modified your code and used a self made QuestionBox instead of messagebox.
The essential part is defining a callback method and letting the QuestionBox call back there. It's not essential I used RAISEEVENT, but it's fine as it has all the behaviour and parameters needed to call back.
Public oTestFrm
oTestFrm=Createobject("MyForm_Model_to_NonModel")
oTestFrm.Show
Define Class MyForm_Model_to_NonModel As Form
onxx = 0
Add Object lbl_DispValue As Label With Top=90, Left = 120, Width = 50, Height=30, Caption=''
Add Object cmd_Start As CommandButton With Top=120, Left = 120, Width = 50, Height=30, Caption='Start'
Add Object cmd_Stop As CommandButton With Top=120, Left = 190, Width = 50, Height=30, Caption='Stop', Enabled =.F.
Procedure cmd_Start.Click
This.Enabled =.F.
Thisform.cmd_Stop.Enabled =.T.
Thisform.onxx = 0
Do While Thisform.onxx < 90000000
DoEvents
Thisform.onxx = Thisform.onxx +1
Thisform.lbl_DispValue.Caption = Transform(Thisform.onxx)
Enddo
This.Enabled =.T.
Thisform.cmd_Stop.Enabled =.F.
Thisform.lbl_DispValue.Caption = ''
Procedure cmd_Stop.Click
* Here, I want NO PAUSE -- (Show running numbers continuously...)
* how to control Model to NonModel in Messagebox.
QuestionBox('Really stop the process', Thisform, 'handleanswer')
Endproc
Procedure handleanswer
Lparameters tlYes
If tlYes && means Stop
Thisform.onxx = 99999999999999999
Endif
Endproc
Enddefine
Procedure QuestionBox()
Lparameters tcMessage, toCaller, tcCallback
If Not Pemstatus(_Screen,"oForms",5)
_Screen.AddObject("oForms","Collection")
Endif
oMsgBox = Createobject("QuestionBoxForm", tcMessage, toCaller, tcCallback)
_Screen.oForms.Add(oMsgBox)
oMsgBox.Show(2)
Endproc
Define Class QuestionBoxForm As Form
Autocenter = .T.
AlwaysonTop = .T.
Minwidth = 200
Add Object label1 As Label With AutoSize=.T., WordWrap =.T.
Add Object cmdYes As CommandButton With Caption = "Yes", Width=40
Add Object cmdNo As CommandButton With Caption = "No", Width=40
Procedure Init()
Lparameters tcQuestion, toCaller, tcCallback
Thisform.label1.Caption = tcQuestion+" ?"
This.AddProperty("oCaller",toCaller)
This.AddProperty("cCallback",tcCallback)
This.Width = Max(This.Minwidth, Thisform.label1.Width)
Thisform.label1.Left = (This.Width-Thisform.label1.Width)/2
This.Height = Thisform.label1.Height+48
This.cmdYes.Left = This.Width/2 - 10 - This.cmdYes.Width
This.cmdNo.Left = This.Width/2 + 10
This.cmdYes.top = Thisform.label1.Height+24
This.cmdNo.top = This.cmdYes.top
Endproc
Procedure cmdYes.Click
#Define clYes .T.
Raiseevent(Thisform.oCaller,Thisform.cCallback,clYes)
Thisform.Release()
Endproc
Procedure cmdNo.Click
#Define clNo .F.
Raiseevent(Thisform.oCaller,Thisform.cCallback,clNo)
Thisform.Release()
Endproc
Enddefine
I didn't yet introduced a timer for counter display updates. As you see the counter hangs a bit, if you mouse over your form, but it is a way of multithreading without using a separate thread and instead keep the rest of the application active by DOEVENTS
in the long running loop code.
Bye, Olaf.
Olaf Doschke - TMN Systemberatung GmbH http://www.tmn-systemberatung.de -
TS4036 how long does the restoration process
How long does the restoration process take
Hi Dottie83,
The extraction of files should not take more than a few minutes. Please cancel and retry.
In case you still face issues consider redownloading the package again.
Alternatively you can try downloading from the direct download links available at : http://prodesigntools.com/adobe-cs6-direct-download-links.html
But make sure you follow the important steps mentioned on the page before initiating the download.
Maybe you are looking for
-
How to save as AI file in same location with all text curves?
Hi Guys, I am also looking for a script. Here are the details.... I do have lot of AI files (from different paths), which are completly work done. So I just need to make them (all files) a copy with all text curves in the same path should create fo
-
How can I put a "esc" character in the command line of the Iinstrument I/O Assistant?
Hello I'm trying to prepare a VI for a device (Ultrasonic detector) connected to my RS-232 serial port, and which requires commands and enquires in the format The problem is very simple....since is a non printable character, how can I put it in the c
-
Alarm not working since 01-01-11
We have two 3g iPhones and since we moved into 2011 neither of the alarms activate at the set time. The countdown timers work ok.
-
The app store thinks all my apps were bought with the same id
When i try to update all my apps (or individually) it always asks me for my main id, but i use 3 different ids, that all have paid apps. i can confirm all apps that will not update have been bought with the other two ids (not the main one). when i tr
-
Using BT HomeHub as a print server
I have an epson printer which I have been using for a couple of weeks with my new mac, and I also have to share it with my brother who uses XP. I connected the printer to the Hub (BT HomeHub v1.5) USB port and managed to make it print through windows