How to configure SLiM to boot before terminal

Hi, I've just installed Archlinux for the first time in a while... it's been a while since I last used Arch and i'm having an issue with the following:
I used to be able to configure some tty5 stuff in a file I can't remember right now to be able to boot my computer directly into my display manager without having to see the login prompt from the terminal. I know it's kind of sillo to get bothered by something like this, but I'd really like to know if there is a way now with systemd to do the same.
PS: My computer DOES boot into SLiM without me doing anything, but I'm able to see the login prompt at the terminal for about a second before SLiM launches.

I guess you could simply create a unit that switches to VT7 (or any other VT you use for X11) early in the boot process.
Use Exec=/bin/chvt 7
Edit: And maybe add console=tty1 to your kernel bootline.
http://zeeky-h-bomb.blogspot.de/2012/09 … ernel.html
Last edited by progandy (2013-09-02 23:19:39)

Similar Messages

  • How to configure V240 auto-boot after power failure?

    Hi!
    How to configure automatic boot of V240 machine after power failure? After power gets resored, V240 remains in standby mode and one has to press button on front to power it up. It is not convinient because power failure can occur, for example, at night and the machine is not booted until the first user awakens :)

    Uhh... I've found publicly accessible document http://docs.sun.com/source/817-5481-11/variables.html :
    Looks like this variable controls auto-power-up behaviour:
    sc_powerstatememory
    The sc_powerstatememory variable enables you to specify the state of the host server as false (keep the host server off) or true (return the server to the state it was in when the power was removed). This is useful in the event of a power failure, or if you physically move the server to a different location.
    For example, if the host server is running when power is lost and the sc_powerstatememory variable is set to false, the host server remains off when power is restored. If the sc_powerstatememory variable is set to true, the host server restarts when the power is restored.
    The values for this variable are as follows.
    true - "Remembers" the state of the host server when power was removed and returns the server to that state when power is reapplied.
    false - Keeps the server off when power is applied.

  • How autostart Interactive program at boot before tty appears

    I'm coming from Ubuntu to Arch Linux, I'm trying to autostart an interactive program written in C++ at boot before tty1 appears.
    I have created a file called /etc/systemd/system/myapp.service with the following contents:
    [Unit]
    Description=myapp
    [Service]
    Type=oneshot
    ExecStart=/home/xxx/myapp.exe start
    StandardOutput=tty
    RemainAfterExit=yes
    [Install]
    WantedBy=multi-user.target
    And then run
    sudo systemctl enable myapp
    Unfortunately, it does not work as expected:
    1. I can't interact with myapp
    2. I do not want tty1 to appear until the program ends
    Last edited by mafrek (2013-09-05 07:30:45)

    thank you . thank you . thank you .
    the secret thing in magic line `StandardInput=tty`
    my final  /etc/systemd/system/myapp.service
    contents:
    [Unit]
    Description=myapp
    After=sysinit.target
    [Service]
    Type=oneshot
    StandardInput=tty
    StandardOutput=tty
    RemainAfterExit=yes
    ExecStart=/home/xxx/myapp.exe start
    ExecStop=/home/xxx/myapp.exe stop
    [Install]
    WantedBy=multi-user.target
    AND i disable tty1
    sudo systemctl disable [email protected]
    Now tty1 is my app (-:
    Another problem )-:
    ExecStop=/home/xxx/myapp.exe stop
    not working, i want run myapp with stop parameter on shutdown/reboot system
    thanks for ( Trilby, progandy )
    Last edited by mafrek (2013-09-06 09:43:13)

  • Satellite U940-108 - How to configure BIOS to boot dual OS from SSD / HDD

    How can i configure the BIOS to boot multi os ssd and HDD?
    I want to boot from SSD one os and other os from HDD,
    When i try to do it i have windows error?
    Can you help me

    Hi
    I assume you want to install the OS (which one???) on the internal mSATA 32GB SSD?
    This mSATA SSD is used for caching (hybrid boot) in order to boot Windows 8 faster.
    I would recommend you to install the second OS on the HDD.
    For that you should create new partition which could be used for OS installation.
    Then boot from the Windows installation disk and install the 2nd OS on the new created partition.

  • How to configure exhausting sick pay before STD

    I would like to find out if is possible to configure exhausting sick pay hours first when an employee is placed on STD.
    In essence they want to use all sick hours before the STD pay kicks in.
    Thank you in advance

    Were you able to successfully configure the STD in SAP Payroll?  We have a similar requirement and I was wondering if you could share any information or documentation. 
    Thanks,
    Cyndi

  • HOw to configure iSCSI remote boot on a SUN Server

    For virtualization I need to use iSCSI remote boot from the SUN Server X2270 to a Disc Storage!
    I've installed the "Intel® Gigabit ET Dual-Port Server Adapters" into this server.
    During the boot time, I didn't see the message "Press <Ctrl-D> to ru setup..." or any message about "Intel iSCSI Remote Boot"! It is like the machine didn't see this Intel Card...
    I didn't known any more what to do? as anyone an Idea about this problem?
    Regards,
    nm

    Log into the global zone and run :
    # shutdown -y -g0 -is
    This should bring down the global zone to su mode and halt the other zones (notice Halt)
    However I believe there is a bug presently where this does not always happen and you are still able to telnet to the local zones.
    Local zone admin could always run zoneadm -z <zone-name> halt on each zone (notice halt not single-user).
    Once global zone in in single-user mode install the patch as normal, when the global is done it will bring up each local zone to single-user mode to add the patch too.
    118833-36 may need patch add and -G option as this patch also has been experiencing some issues, in which case I believe you would need to do the patch add process on each zone manually
    Once the global zone is brought back up again it should bring up the local zones as well.
    Let us know if you experience the locals not being halted as mentioned above and need to do it manually.

  • How to configure windows services alerts in SCOM 2012 for all agent servers. For eg, Terminal Services, Netlogon, RPC etc..

    Hi,
    I need to configure different windows services alerts in SCOM 2012. Below are some of the windows services I need to monitor through SCOM.
    Serivce: Windows Management Instrumentation
    Service: Netlogon
    Service: Remote Procedure Call (RPC)
    Service: Server Service
    Service: Terminal Services
    Service: Windows Time
    Service: Workstation
    Service : WWW Publishing Service
    Could some one please assist or share me the details, how to configure these services for windows agent servers.
    Thanks..
    Regards, Rajeev Parambil

    Hi,
    A certain set of services are monitored by default on all agents:
    DNS Client
    DHCP Client
    RPC
    Workstation
    Server
    For all the other services you could create a service monitor.
    A nice blog series outlining this process can be found here: http://www.bictt.com/blogs/bictt.php/2011/03/16/scom-monitoring-a-service-part1
    It's doing common things uncommonly well that brings succes. Check out my SCOM link blog:
    SCOM link blog

  • [SOLVED]How to configure pptp vpn start on boot with netcfg?

    I've configured 2 profiles:
    eth0 and ppp0, where ppp0 is a pptp vpn tunnel.
    $ ls /etc/network.d/
    eth0  examples  interfaces  ppp0
    $ cat /etc/network.d/ppp0
    CONNECTION='ppp'
    INTERFACE='ppp0'
    PEER='dxt'
    PPP_TIMEOUT=10
    $ cat /etc/conf.d/netcfg
    # Enable these netcfg profiles at boot time.
    #   - prefix an entry with a '@' to background its startup
    #   - set to 'last' to restore the profiles running at the last shutdown
    #   - set to 'menu' to present a menu (requires the dialog package)
    # Network profiles are found in /etc/network.d
    NETWORKS=(eth0 ppp0)
    # Specify the name of your wired interface for net-auto-wired
    WIRED_INTERFACE="eth0"
    # Specify the name of your wireless interface for net-auto-wireless
    WIRELESS_INTERFACE="wlan0"
    Manually, I can start up ppp0 correctly.
    $ sudo netcfg -u ppp0
    :: ppp0 up                                                                                                                                                                 [ BUSY ] Using interface ppp0
    Connect: ppp0 <--> /dev/pts/3
    CHAP authentication succeeded
    MPPE 128-bit stateless compression enabled
    Cannot determine ethernet address for proxy ARP
    local  IP address 10.100.3.132
    remote IP address 10.100.3.1
                                                                                                                                                                               [ DONE ]
    $ ip addr list dev ppp0
    8: ppp0: <POINTOPOINT,MULTICAST,NOARP,UP,LOWER_UP> mtu 1496 qdisc pfifo_fast state UNKNOWN qlen 3
        link/ppp
        inet 10.100.3.132 peer 10.100.3.1/32 scope global ppp0
    But after booting, only eth0 is up. How to configure ppp0 to start on boot with netcfg?
    Last edited by rchiang (2012-12-21 01:09:32)

    Thanks a lot for your instruction.
    netcfg works now!
    chris_l wrote:
    Did you
    systemctl enable [email protected]

  • How to configure Grub or enable dual boot Windows7 & Oracle Enterprise Linux6

    Hi,
    I had Windows 7 installed on my PC and later on I have installed Oracle Linux6 (Server).
    While installation I didn't get any option to configure dual boot and now I am unable to boot Windows7.
    If I do fsdik -l command on Linux prompt, I get the result:
    # fdisk -l
    Disk /dev/sda: 160.0 GB, 1600041885696 bytes
    255 heads, 63 sectors/track, 19457 cylinders
    Units = cylinders of 16065 * 512 = 8225280 bytes
    Sector size (logical/physical): 512 bytes / 512 bytes
    I/O size (minimum.optimal): 512 bytes / 512 bytes
    Disk identifier: 0x9143f05b
    Device           Boot     Start     End     Blocks          Id     System
    /dev/sda1       *          1          1305    10482381     83     Linux
    /dev/sda2                  1306     6405    40960000      7       HPFS/NTFS
    /dev/sda3                  6405     12779  51200000      7       HPFS/NTFS
    /dev/sda4                  12779    19458 53646336      7       HPFS/NTFS
    I check the grub config file at /boot/grub/menu.lst but I do not see any entry for windows here.
    Please advise how to configure grub or other way to make the dual boot options enable and use windows and linux.
    Thanks in Advance.
    Anand

    Could you post your menu.lst file?
    It's not clear which exact partition Windows 7 is on from fdisk -l, but you could try adding this to your menu.lst file:
    title Microsoft Windows 7
    root (hd0,1)
    savedefault
    makeactive
    chainloader +1

  • How can I get Firefox to boot before windows?

    My hard drive will not boot or read. I'm using Windows 7 and apparently it's a virus infected nothing works except for the blue screen of death. Can't I use Firefox to boot my computer instead of windows? How do I get to boot during the start up?

    Start your '''Computer''' in safe mode with networking.
    '''[http://encyclopedia2.thefreedictionary.com/Linux+Safe+Mode Starting The Computer In Safe Mode;<br>Free Online Encyclopedia]'''
    If the menu has a '''Repair''' option, try using it.
    If you can't fix this yourself, you will need a tech. Good luck.

  • How to configure multiple IP-Adresses on one NIC in OVM

    Hi guys,
    we have some OVM Servers 2.2.1 installed. They all have three NICs in them (eth0-2). For eth0 and eth2 we need multiple IP-Adresses configured to work with our storage solution. The configuration should look like this:
    eth0:0 - 192.168.31.x
    eth0:1 - 192.168.33.x
    eth1 - 192.168.0.x
    eth2:0 - 192.168.32.x
    eth2:1 - 192.168.34.x
    I tried creating gonfig files ifcfg-eth0:0 in /etc/sysconfig/network-scripts with the following content
    DEVICE=eth0:0
    BOOTPROTO=static
    ONBOOT=yes
    NETMASK=255.255.255.0
    IPADDR=192.168.31.3
    TYPE=Ethernet
    HWADDR=00:1b:21:06:f0:fa
    But it does not work. Neither eth0:0 nore an additional xenbr is configured when i restart.
    I can configure multiple ip addresses for xenbr0 by calling something like "ifconfig xenbr0 192.168.31.x". But these settings get lost as sonn as i reboot the server.
    I have already searched google, forums and blogs for a solution but could not find one. I thought that this should be a pretty common task. In "normal" linux it is not an issue at all.
    Has somebody any experience with a setup like this? I would really apreciate your help.
    Thanks
    Marek

    Hi,
    configuring IP aliasses seems to work the same way like configuring VLANs. You will have to configure the appropriate bridges at system startup manually.
    E.g. this little script is what I use to configure VLANs and briges on my OVM:
    #!/bin/bash
    echo "Configuring VLANs and bridges\n"
    echo "Configuring VLAN 24 on eth2"
    vconfig add eth2 24
    brctl addbr br2.24
    brctl addif br2.24 eth2.24
    ifconfig eth2.24 up
    ifconfig br2.24 up
    echo "Configuring VLAN 31 on eth2"
    vconfig add eth2 31
    brctl addbr br2.31
    brctl addif br2.31 eth2.31
    ifconfig eth2.31 up
    ifconfig br2.31 up
    This script is run at startup by init using this startup skript in /etc/init.d, which is what I think you're missing as you can already seem to bring up the needed IPs manually - you'd have to change the chkconfig accordingly, that is make sure that the config script gets startet after the network has been brought up, like this: # chkconfig: 2345 11 91
    [root@oraclevm01 ~]# cat /etc/init.d/vlan-config
    #! /bin/bash
    # vlan-config configure VLANs
    # chkconfig: 2345 11 89
    # description: Configures VLANs at boot time before the \
    # network is started.
    ### BEGIN INIT INFO
    # Provides: $vlan
    ### END INIT INFO
    # Source function library.
    . /etc/init.d/functions
    if [ ! -f /etc/vlan-config ]; then
    exit 0
    fi
    # See how we were called.
    case $1 in
         start)
                   # configure vlans
                   /etc/vlan-config
              echo $"Usage: $0 {start}"
              exit 1
    esac
    exit 0
    Hth,
    budy
    Edited by: budachst on Jun 29, 2011 8:11 AM

  • How to configure link between 2921 and SM-D-ES3G-48-P EtherSwitch Service Module

    hi,
    I can't do that like the procedure given by Cisco.
    http://www.cisco.com/en/US/partner/docs/routers/access/interfaces/software/feature/guide/eesm_sw.html#wp1942894
    Cisco Procedure :
    interface gi10/0
    ip address x.x.x.x x.x.x.x
    service-module gigabitethernet 1/0 session
    My result :
    R2921-8CPITR-1(config)#int gi 1/1
    R2921-8CPITR-1(config-if)#ip address 2.2.2.2 255.255.255.192
    % IP addresses may not be configured on L2 links.
    R2921-8CPITR-1(config-if)
    R2921-8CPITR-1(config)#interface gigabitEthernet 1/1.1 ?
    % Unrecognized command
    R2921-8CPITR-1(config)#interface gigabitEthernet 1/1 ?
      <cr>
    R2921-8CPITR-1(config)#
    the session is not possible also ?
    R2921-8CPITR-1#service-module gigabitEthernet 1/1 sess
                                                      ^
    % Invalid input detected at '^' marker.
    R2921-8CPITR-1#
    The routeur said that it's not a L3 port, so how to configure it to allow communication between the 2921 and the card ?
    Is there a bug with that version I'm in 15.1(4)M4 ????
    R2921-8CPITR-1#sh ver
    Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.1(4)M4, RELEASE SOFTWARE (fc1)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2012 by Cisco Systems, Inc.
    Compiled Tue 20-Mar-12 18:57 by prod_rel_team
    ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
    R2921-8CPITR-1 uptime is 19 hours, 21 minutes
    System returned to ROM by power-on
    System restarted at 16:00:45 GAB Fri Sep 14 2012
    System image file is "flash0:c2900-universalk9-mz.SPA.151-4.M4.bin"
    Last reload type: Normal Reload
    This product contains cryptographic features and is subject to United
    States and local country laws governing import, export, transfer and
    use. Delivery of Cisco cryptographic products does not imply
    third-party authority to import, export, distribute or use encryption.
    Importers, exporters, distributors and users are responsible for
    compliance with U.S. and local country laws. By using this product you
    agree to comply with applicable laws and regulations. If you are unable
    to comply with U.S. and local laws, return this product immediately.
    A summary of U.S. laws governing Cisco cryptographic products may be found at:
    http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
    If you require further assistance please contact us by sending email to
    [email protected].
    Cisco CISCO2921/K9 (revision 1.0) with 479232K/45056K bytes of memory.
    Processor board ID FGL1618119E
    6 Gigabit Ethernet interfaces
    2 terminal lines
    DRAM configuration is 64 bits wide with parity enabled.
    255K bytes of non-volatile configuration memory.
    250880K bytes of ATA System CompactFlash 0 (Read/Write)
    License Info:
    License UDI:
    Device#   PID                   SN
    *0        CISCO2921/K9          FGL1618119E
    Technology Package License Information for Module:'c2900'
    Technology    Technology-package           Technology-package
                  Current       Type           Next reboot
    ipbase        ipbasek9      Permanent      ipbasek9
    security      None          None           None
    uc            None          None           None
    data          None          None           None
    Configuration register is 0x2102
    R2921-8CPITR-1#

    Same issue here.
    I just waited a few minutes and the interface went down and back up, this time it was a L3 interface.
    My guess is that it was booting the switch module IOS, and it detected it until it was fully booted:
    Apr 11 05:26:52.091: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
    Apr 11 05:26:52.091: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
    Apr 11 05:26:52.091: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
    Apr 11 05:26:52.091: %LINK-3-UPDOWN: Interface GigabitEthernet1/0, changed state to up
    Apr 11 05:26:52.795: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
    Apr 11 05:26:53.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
    Apr 11 05:26:53.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
    Apr 11 05:26:53.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
    Apr 11 05:26:53.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0, changed state to up
    Apr 11 05:27:46.895: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
    Apr 11 05:27:46.895: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
    Apr 11 05:27:46.947: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
    Apr 11 05:27:47.031: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
    Apr 11 05:27:47.083: %LINK-5-CHANGED: Interface GigabitEthernet1/0, changed state to administratively down
    Apr 11 05:27:47.895: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
    Apr 11 05:27:48.083: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0, changed state to down
    Apr 11 05:27:49.283: %IP-5-WEBINST_KILL: Terminating DNS process
    Apr 11 05:27:52.499: %LINK-3-UPDOWN: Interface GigabitEthernet1/1, changed state to up
    Apr 11 05:27:53.087: %SYS-5-RESTART: System restarted --
    Cisco IOS Software, C2951 Software (C2951-UNIVERSALK9-M), Version 15.1(4)M5, RELEASE SOFTWARE (fc1)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2012 by Cisco Systems, Inc.
    Compiled Tue 04-Sep-12 16:50 by prod_rel_team
    Apr 11 05:27:53.255: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
    Apr 11 05:27:53.499: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1, changed state to up
    Apr 11 05:28:21.435: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up
    Apr 11 05:29:22.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1, changed state to down
    Apr 11 05:29:22.095: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
    Router>en
    Router#sh ip int brief
    Interface                  IP-Address      OK? Method Status                Protocol
    Embedded-Service-Engine0/0 unassigned      YES unset  administratively down down
    GigabitEthernet0/0         unassigned      YES unset  administratively down down
    GigabitEthernet0/1         unassigned      YES unset  administratively down down
    GigabitEthernet0/2         unassigned      YES unset  administratively down down
    GigabitEthernet1/0         unassigned      YES unset  administratively down down
    GigabitEthernet1/1         unassigned      YES unset  up                    down
    Vlan1                      unassigned      YES unset  down                  down
    Router#
    Apr 11 05:29:46.106: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1, changed state to upconf t
    Enter configuration commands, one per line.  End with CNTL/Z.
    Router(config)#int g1/0
    Router(config-if)#ip add 1.1.1.1 255.255.255.0
    Router(config-if)#no shut
    Router(config-if)#
    Apr 11 05:30:09.046: %LINK-3-UPDOWN: Interface GigabitEthernet1/0, changed state to up
    Apr 11 05:30:10.046: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0, changed state to up
    Router(config-if)#end

  • How to Configure my url in Apache server?

    i have an Apache webserver.i want to give url as desired say.http://intranet.com. Now iam giving my machine ip address as "127.0.101:9000 "to get my html page displayed from a remote terminal in a intranet network.
    How to configure the apache so that i can replace the ip address with my desired name url type. Please help me.

    How to configure the apache so that i can replace the
    ip address with my desired name url type. Please help
    me.Apache cannot do anything about this . It is your network DNS and DHCP that does this for you .If u edit the hosts file in a pc on ur lan ,then u can invoke from this m/c with the string as long as ur m/c isnt re-booted .This is assuming that u do not have a static IP adress .

  • How to configure RAID 5 sys using SAS controller for APP CS4

    Hi I would like to know how to configure my 3 HardDrives (600GB each) on RAID 5 connected to SAS controller to work smoothly with PremierePro CS4. Mainly to store scratch disk, and all preview files, etc.. At present it shows as one big hard drive in C:\ It shows as follows: OS(C 0.98 TB free of 1.08TB I would like to have at least one HDD out of 3 to store my scratch disk files and preview files... I have installed only CS4 Master Collection + Windows 7 64bit Ultimate as OS in this machine. Following is my system configuration: Intel Xeon E5620, 2.4GHz processor/12M Cache, 5.86GT/S, QPI, Turbo, HT, 4C Intel 5520 Chipset 12GB DDR3 RDIMM Memory,1333MHz, ECC Three 600GB (15000rpm) SAS HardDrives Perc6/i SAS/SATA Harware RAID card All SAS Drives, RAID 5, 3 drive configuration BlueRayBurner1GB PCIe X16 nVidia Quadro FX3800 ,Dual monitor DP+1 DVI Capable I am in a little bit strife on this. I am in a little bit strife on this and Open for any good and effective suggestions are much appreciated. Thanks Nathapushpa

    You even have three more connectors free on your Perc controller, so you could add three more disks, without using any motherboard connectors.
    I think you have two alternative approaches:
    1. Add a smallish disk as a boot disk, i.e. a 150 GB Velociraptor and install OS and programs there and let your raid5 exist as it is, or
    2. Add another 600 GB to your raid5 to make it a four disk array.
    Of course you could also do both. Breaking the raid out to individual disks means that all data on the current raid will be lost, unless you have a backup available, but it will still mean a fresh install of OS & programs, so remember to deactivate Adobe before you do anything to your disk setup like in alternative 1 or breaking out the array.

  • How to configure multiple IP addresses on one NIC?

    Hi,
    I just installed a OVM Server in version 3.2.1 and the according VMManager. Now i wanted to try to configure the Server/Server Pool. Now i come across a problem, which was already a big problem in OVM 2 while configuring the Networks.
    All our OVM Servers have three NICs in them. One is for VMs and Management, the others are for connection to our SAN (Dell PowerVault MD 3220i). My problem is, that due to the network setup, the two NICs for storage need two IP addresses in two different networks each. This shouldn't be a problem, because usually in linux all you have to do is configure something like eth1:1. I remember having huge trouble configuring it in our OVM 2 cluster up to the point where I had to write a shell script to configure the second IP.
    Anyways, I have configured two of the storage networks on eth1 and eth2 of the VM Server. Now i cannot configure any more IP addresses, because eth1 and eth2 are not available anymore for configuration in a third network. I really hoped that it would be possible in OVM 3 to configure multiple IP addresses. And probably it is only my lack of knowledge of how to configure it.
    So any advice is well appreciated.
    Thanks!
    Regards,
    Marek Hubatka

    You should be able to do this by using "VLAN Groups".
    http://docs.oracle.com/cd/E35328_01/E35332/E35332.pdf
    Check out the VLAN groups section. You must great the VLAN groups before you can assign them to interfaces.

Maybe you are looking for

  • Problem with IBM JVM or the Thread

    Hi All, I have a class which implements Runnable. The purpose of the program is to read a file and count the number of lines present in that. I am using the IBM JVM. The logic runs like this.. For each 2048 bytes read , it spawns a new thread with th

  • I'm having trouble finding carton hd on the app store

    I'm having trouble finding carton hd on the App Store

  • Margins, footer, TOC issues

    I have 2 issues formatting my newsletter. After going through forum postings for the last year and experimenting a bit, my need of having a TOC entry without visible Heading text has gotten a workaround. Apparently doing anything with Headings and te

  • Re-install Photoshop without the disc or registration number

    My computer is starting to run really slow and it consistently freezes up when I run Photoshop and other applications. I want to reset my computer to its factory settings to get rid of any virus or other bad programs that were installed. However, I d

  • My calendars were erased today

    I have not upgraded to Lion.  When I opened up my iCal this morning AFTER I synced my iPad all the calendars were gone.  I had about 7 calendars, months of appointments, critical accounts to keep up with, etc. Can I get any of this back?  I still hav