Implausible meter reading flag-table/field

Hi
Is there any flag goes into the DB against implausible meter reading against any business/technical master data, please specify the table/field if known.
Gaurav Upadhyaya

Hi Gaurav,
As mentioned above, the field ABLSTAT (Meter Reading Status) in table EABL would let you know if a meter reading is plausible or not. The values of implausible meter reads are:
2     Automatically Locked
3     Locked by Agent
U can reach the table EABL as follows:
ANALAG (installation) using tables EABLG by getting the meter read doc no.
Hope this helps
Thank you,
Binno Don Thomas

Similar Messages

  • EL 27 Correction of Implausible Meter Reads

    Hi All,
    I am trying to release impalusible Meter Readings via TCode EL27, by entering a Premise. Two things are happening:
    1. Direct Release of MR occurs . (no idividual correction screen opens)
    2. Individual Correction screen opens. (no direct release)
    I debugged quite a few cases and have reached a few conclusions:
    FOR INDIVIDUAL CORRECTION SCREEN TO OPEN:
    Pre-requisite = Value of ORIGIN_ESTIM = 6
    With this pre u2013 requisite, when there is 1 installation, with 1 register then in EL27, individual correction screen will open and MRu2019s can be edited.
    FOR DIRECT RELEASE:
    Apart from the above prerequisite & condition, FOR u201CANY OTHERu201D CONDITION, the correction screen will not open and MRu2019s cannot be edited.
    Value of Origin_estim can be viewed on the individual correction screen "Execute Correct Implausible Meter Reading Results" screen; Forecast data tab--> Origin
    Values of Origin:
    1 - Past MR results
    2 - Period Consumption
    3 - Reference value
    4 - Proration
    5 - External Determination
    6 - Estimation not Possible
    Also, is this phenomenon of direct release/ correction screen display DEPENDENT on MR REASON???
    Thanks in advance,
    Prajakt Dhumal
    Edited by: prajakt k dhumal on Oct 28, 2010 9:28 AM

    Hello,
    It should be possible to get to the correction screen by selecting the line you want to correct an click on 'correct'...
    You could skip this and release directly but there should be always an option to go into the correction screen as long as the meter reading is "still implausible".
    Only time this happens is if the meter reading is automatically plausible e.g. if no extrapolation was possilbe. You should get a
    message about this.
    It will only enter the correction screen if there is an "invalid meter reading result". If it is valid now (without doing changes) there is no need for correction anymore therefore it is released immediately.
    The correction screen is not build to handle more than one meter reading at a time. Hence there is no way you correct more than one meter reading at the same time i.e. count_eabl >= 2.
    Hope this is helpful ...
    Regards
    Olivia

  • What is Meter reading validations (System defined & User defined)

    Hi Experts,
    1 )How to configure Meter Readings (Technical Control Parameters, MR Control, MR Notes etc)
    2) what is Meter reading validations (System defined & User defined) and how to configure it.
    3) What is Register Relationships,Device Groupings & Device Allocations and how to configure.
    Kindly explain with examples.
    Thanks in advance.
    Regards,
    Shabnum

    hi,
    Meter Validation Steps:
    1.     The Validation Process begins with Meter Reading Order Creation when the expected consumption is determined for the meter reading to be recorded for each register. The meter reading status is u201C0u201D or un-entered at this time.
    2.     The meter reading is entered via an upload program as part of the batch processing or entered manually.
    This result is validated or evaluated against the permitted range of allowable meter reads/consumption for that register.  The expected consumption is the basis for determining the range of the minimum and maximum values for the meter reading.
    If the result is plausible, or valid, for all registers of the meter, the billing order becomes billable and the contract/installation is passed to billing for further processing. The meter reading status is updated to u201C1u201D or billable.
    If the meter reading is validated as implausible, the meter reading result is transferred to the List of Implausibles for further processing (EL70). The status of the meter reading is u201C2u201D or automatically blocked. One or more independent validations can be failed in this validation process.
    3.     During processing, the agent can release the meter reading for billing; the status is updated to u201C4u201D, released by clerk. The reading is accepted as measured. The agent can also process the implausible meter reading result using transaction code: EL27 Execute Correct Implausible Meter Reading Results. EL27 is recommended for individual processing.
    SAP Easy Access  Utility Industry  Device Management  Meter Reading  Correction of Meter Reading Results  Implausible Results (Transaction EL27)
    EL70 is recommended for processing of implausibles for mass processing.  It is not on the menu, however, one way to open the screen is:
    SAP Easy Access  Utilities  Device Management  Meter Reading  Correction of Meter Reading Results  Implausible Results
    Once the screen opens, click on the List button on the application toolbar
    4.     The agent may also correct the meter reading. If this corrected read is validated as within range, the status is updated to u201C1u201D, billable.
    5.     Alternatively, the reading can be determined to require follow up action and a service order is executed from the IC for re-read. A read status has been configured to support this flagging of the account for follow-up service order processing.
    6.     When the service order is returned from the field, the CSR releases corrects, resets or possibly estimates the meter reading depending on the outcome of the service order processing.
    7.     The meter reading is then passed to the billing engine for billing execution when the reading is validated as plausible.
    -Siva

  • Function Module/BAPI  for Meter Reading Entry(EL28)

    Hi Experts,
    Can anyone tell me about BAPI/Function Module for EL28(Meter Reading Entry).Standard FM is preferable.
    Thanks & Regards,
    Radharaman Haldar
    Moderator note - Thread locked, no research.
    Edited by: William Eastman on Mar 8, 2011 5:17 PM

    ISU_VALIDATION_DEPENDENT & ISU_DETERMINE_VALIDATION.
    The above two function module is used for the validation of Plausible or Implausible meter reading.

  • MRO and Meter Read report and reconciliation

    Hi,
    I am creating Meter read orders for all MRU's in a portion and need to reconcile the number of orders created and after the read results have been received, i again need to check for how many orders reads have been received and how many are still open.
    What is the standard way of doing this. I am aware of using EABL and EABLG. Will again need to understand what is a better way.
    Thanks,
    Monis Shakeel

    we have a custom report which counts the number of orders, & results every day. After a few days the orders are filled (mostly) & business processes monitor the outstanding open orders.
    The report is based on the schedule records (TE417 & TE418) as well as the meter reading results tables (EABL/G)
    Alternatively:  transaction EL32 can be used to monitor meter reading data.
    SAP Utilities --> Device Management --> Meter Reading --> Basic Settings --> Define Automatic Monitoring of Meter Reading Data
    However we've never used this functionality so I have very limited experience with its subtleties.
    user exit EDMLADUE is utilized here.
    I'd be interested in any 'better way' you end up pursuing.

  • DM - Meter Reading Workflow functionality

    Hi all,
    I have a customer's requirement that the estimated MR should be "corrected" automatically in case the next actual MR arrives and it is less then the estimation done before.
    Can anybody help me via the customizing and the development (if any required)?
    I have found the Customizing section Define Automatic Monitoring of Meter Reading Data, that works in co-operation with the function module EXIT_SAPLEL01_020, but I am not sure if this is the recommended way of solving this problem.
    Thanks in advance for your feedback, regards,
    Bou.Lis

    Hi Bou.Lis,
    Standard SAP Triggers the event ASSESSED in the Business object - ISUCONTRCT.  Use this to assess the meter reads and estimate the reads.
    Obviously you may also need to cancel the billing documents if you are adjusting the meter reads for the period billed. In that scenario you can use BILLDOCAUT -> BDOCSFORREVERSAL and BILLDOCAUT -> ADJREVERSETAB.
    For re-estimation you can leverage using the FM ISU_ACTION_ASSESSING. This FM estimates for all the registers, so you might want to customize and re-estimate only for implausible meter reads registers.
    I would recommend working with a solid workflow developer who has IS-U knowledge.
    Hope this helps.
    Sai

  • How to read table fields form a table  having length of 7 characters

    HI all,
    could you please tell me how to read table fields from a table having length 7 characters, i have requirement that in my ztable i have 30 fields out of which 20 fields are location fields, i want to select 20 fields which have 7 characters length.
    please could any body suggest me on this issue.
    thanks,
    sre.

    hi,
    try like this
    create a data variable of type i as
    data: len type i.
    create internal table for 20 fields as
    data:begin of itab,
               fld 1 type .......
            end of itab.
    data:itab type itab1 occurs 0 with header line.
    loop at itab2. // original internal table which all fields.
    read table itab2 with index sy-tabix.
    len = strlen (itab2-fld).
    if len eq 7.
          move itab2 itab1.
          append itab1.
    endif.
    endloop.
    if helpful reward some points.
    with regards,
    Suresh.A

  • In which table recorded meter reading exits?

    Hi All,
    Can anyone tell me in which table recorded meter reading stored?
    Thanks in advance

    Hi,
    Meter reading is stored in EABL table in filed V_ZWSTAND.
    Regards,
    Pranaya

  • Update Flag Field for Same Day in a Given Month Every Year in a Flag Table.

    Hi,
    I am trying to formulate an update query for a flag table in our database which contains dates, and flag columns. Currently the system have dates for the next ten years. The flags are updated with values 0 or 1 if a particular date falls under the required criteria.
    I need to update flag column for the same day of the month in every year. e.g. 2nd Sunday of October. The value should be updated to all years in the table. Currently I am using the following query to update the current year.
    UPDATE FILTERCALENDAR SET YEAR_WINDOW=1 WHERE c_date = NEXT_DAY( TO_DATE('OCT-2013','MON-YYYY'), 'SUNDAY') + (2-1)*7;
    and for next year Like
    UPDATE FILTERCALENDAR SET YEAR_WINDOW=1 WHERE c_date = add_months(NEXT_DAY( TO_DATE('OCT-2013','MON-YYYY'), 'SUNDAY') + (2-1)*7,+12)-1;
    This is not an excellent way to do it as it does not take care of leap years and it does not scan and update values in the whole table for all years correctly.
    Can any one help me to resolve this please.
    Hamidch

    Resolved by doing the following:
    Just query the years from your table (list of distinct years) and use the above query on them.
    SELECT DISTINCT TO_CHAR(c_date, 'yyyy') FROM FILTERCALENDAR
    Or use this predicate
    WHERE c_date = next_day(last_day(add_months (c_date, -1)), 'SUNDAY') + 7
    AND TO_CHAR(c_date, 'mm') = '10'

  • Attaching search help to SCREEN FIELDS AND TABLE FIELDS

    Hello experts,
    Himanshu here.
    Could you please explain how we can assign search Help to a screen field AND TABLE FIELDS in ABAP?
    Please reply at the earliest,as we have some deliverables to be met
    Thanks

    Hi,
    In the initial screen of the ABAP Dictionary, select object class Search help, enter the name of the search help and choose Create.
    A dialog box appears in which you must select the type of search help.
    Select Collective search help and choose .
    The maintenance screen for collective search helps is displayed.
    Enter an explanatory text in the field Short text.
    You can for example find the search help at a later time using this short text.
    In the Definition tab page enter the parameters of the collective search help.
    Select the Imp flag if it is an import parameter. Select the Exp flag if it is an export parameter.
    Define the types for the parameters of a collective search help by assigning a data element. Enter the name of the data element that describes the contents of the search help parameter in the Data element field.
    You can assign the parameter a default value in the Default value field.
    In exceptions it could be necessary to change the standard process defined by the search help. You can implement the deviation from the standard using a search help exit.
    In this case enter the name of the search help exit in the corresponding field.
    On the Included search helps tab page, define the search helps that you want to include in the collective search help.
    You can include elementary search helps and collective search helps.
    Use the Hide flag to control whether an included search help should appear in the dialog box for selecting the elementary search help. If the flag is set, the search help is not offered.
    It makes sense to hide search help inclusions if one or more search paths in the standard system should not be used in a concrete R/3 System. Similarly, search help inclusions can also be already hidden in the standard system because they only can be used meaningfully in a few R/3 Systems. You have to cancel the flag in this case.
    Position the cursor one after the other on each allocated search help and choose Parameter assignment.
    In the next screen, enter the parameter names of the elementary search helps to which the corresponding parameters of the collective search help should be assigned in the field Reference parameter.
    You can select the parameters contained in the included search help using the input help. Create a proposal for the assignment with Proposal.
    Save your entries.
    A dialog box appears in which you have to assign a development class to the search help.
    Choose .
    Result
    The collective search help is activated. You can find information about the activation flow in the activation log, which you can display with Utilities ® Activation log. If errors occurred when the collective search help was activated, the activation log is automatically displayed.
    Do not forget to link the search help to a screen field. The search help attachment is not part of the search help definition; it is part of the object definition to which the search help is attached.
    regards,
    veeresh.

  • Help with writing and retrieving data from a table field with type "LCHR"

    Hi Experts,
    I need help with writing and reading data from a database table field which has a type of "LCHR". I have given an example of the original code but don't know what to change it to in order to fix it and still read in the original data that's stored in the LCHR field.
    Basically we have two Function modules, one that saves list data to a database table and one that reads in this data. Both Function modules have an identicle table which has an array of fields from type INT4, CHAR, and type P. The INT4 field is the first one.
    Incidentally this worked in the 4.7 non-unicode system but is now dumping in the new ECC6 Unicode system.
    Thanks in advance,
    C
    SAVING THE LIST DATA TO DB
    DATA: L_WA(800).
    LOOP AT T_TAB into L_WA.
    ZDBTAB-DATALEN = STRLEN( L_WA ).
    MOVE: L_WA to ZDBTAB-RAWDATA.
    ZDBTAB-LINENUM = SY-TABIX.
    INSERT ZDBTAB.
    READING THE DATA FROM DB
    DATA: BEGIN OF T_DATA,
                 SEQNR type ZDBTAB-LINENUM,
                 DATA type ZDBTAB-RAWDATA,
               END OF T_TAB.
    Select the data.
    SELECT linenum rawdata from ZDBTAB into table T_DATA
         WHERE repid = w_repname
         AND rundate = w_rundate
         ORDER BY linenum.
    Populate calling Internal Table.
    LOOP AT T-DATA.
    APPEND T_DATA to T_TAB.
    ENDLOOP.

    Hi Anuj,
    The unicode flag is active.
    When I run our report and then to try and save the list data a dump is happening at the following point
    LOOP AT T_TAB into L_WA.
    As I say, T_TAB consists of different fields and field types whereas L_WA is CHAR 800. The dump mentions UC_OBJECTS_NOT_CONVERTIBLE
    When I try to load a saved list the dump is happening at the following point
    APPEND T_DATA-RAWDATA to T_TAB.
    T_DATA-RAWDATA is type LCHR and T_TAB consists of different fields and field types.
    In both examples the dumps mention UC_OBJECTS_NOT_CONVERTIBLE
    Regards
    C

  • How can i get to know what is the reason for implausible meater reading?

    Hi All,
    I am new to this SAP -ISU.
    can any body tell me how can i get the reason for implausible meater reading.
    my requirement is to get the unbilled meters becasuse of unrealibility of meter reader.
    here what i understood is if meater reading is not in a position to bill so it means meater reading may be in implausible state. so i want to know the reason for implausible meater reading so that i get the meters which are not billed because of unreliasility of meter reader.
    in which table these reasons get store.
    if any body knows about these please reply me ASAP.
    Thanks in Advance.

    At the very least, you will receive EXACTLY the same product you sent in.  You may get a newer product.  It's Apple's choice.

  • ALV fields which are not referenced to data dictionary table fields

    Hello,
    I am using function module reuse_alv_popup_to_select.
    How do I display fields in ALV which are not referenced to
    data dictionary table fields.
    I am showing 4 columns in alv out of which first column is checkbox
    and remaining 3 columns are from data dictionary and it works fine.
    Now I need to add one more column which is of type checkbox.
    I have added this field in my ITAB as flag(1) type C.
    When I add this flag field in the field catalog, I get exception.
    Regards,
    Vishal.

    Hey guys,
    Finally I got rid of such a stupid problem.
    There were no problem in the code.
    while assigning fieldname to field catalog I had given fieldname
    in lowercase.
    I changed it to uppercase and problem got solved.
    Thanks,
    Vishal.

  • BAPI for meter reading order (MRO) Reversal

    Hi Experts,
    Please let me know if there is any FM or BAPI for meter reading order reversal, Similar to EL37
    Regards
    Bikas

    Hello Bikas,
    Though this is an old post, thought of replying for the sake of googlers who might look for a solution for your query...the below code works!
    *---Begin Of Code
      TYPES : BEGIN OF ty_meter_orders_data,
               anlage   TYPE eablg-anlage,
               adatsoll TYPE eablg-adatsoll,
               ablesgr  TYPE eablg-ablesgr,
              END OF ty_meter_orders_data.
      DATA : lt_meter_orders_data TYPE STANDARD TABLE OF ty_meter_orders_data,
                  xy_ieabl_delete   TYPE  eabl_tab,
                  xy_ieablg_delete  TYPE  eablg_tab,
                  xy_ietrg_delete   TYPE  etrg_tab,
                  x_anlage type anlage,
                  x_retro_upd_date type adatsoll,
                  y_return type char1.
      DATA : y_obj TYPE  isu17_meterread.
    *--Get the needed data for reversal
      SELECT a~anlage
             a~adatsoll
             a~ablesgr
        FROM eablg AS a
        INNER JOIN eabl AS b ON a~ablbelnr = b~ablbelnr
        INTO TABLE lt_meter_orders_data
        WHERE a~anlage = x_anlage AND
              a~adatsoll >= x_retro_upd_date AND
              b~ablstat = '0'. "MR Order
      IF sy-subrc = 0.
        SORT lt_meter_orders_data BY anlage ablesgr adatsoll.
        DELETE ADJACENT DUPLICATES FROM lt_meter_orders_data COMPARING anlage ablesgr adatsoll.
        SORT lt_meter_orders_data BY adatsoll DESCENDING.
        LOOP AT lt_meter_orders_data ASSIGNING FIELD-SYMBOL(<fs_meter_orders_data>).
          CALL FUNCTION 'ISU_O_METERREAD_OPEN'
            EXPORTING
              x_anlage              = <fs_meter_orders_data>-anlage
              x_adatsoll            = <fs_meter_orders_data>-adatsoll
              x_ablesgr             = <fs_meter_orders_data>-ablesgr
              x_select2             = '5'
              x_wmode               = '6'
            IMPORTING
              y_obj                 = y_obj
            EXCEPTIONS
              not_found             = 1
              foreign_lock          = 2
              internal_error        = 3
              input_error           = 4
              existing              = 5
              number_error          = 6
              general_fault         = 7
              system_error          = 8
              manual_abort          = 9
              gasdat_not_found      = 10
              no_mrrel_registers    = 11
              internal_warning      = 12
              not_authorized        = 13
              not_qualified         = 14
              anpstorno_not_allowed = 15
              already_billed        = 16
              dev_already_prep      = 17
              OTHERS                = 18.
          IF sy-subrc = 0.
            CALL FUNCTION 'ISU_O_METERREAD_ACTION'
              EXPORTING
                x_okcode             = 'PSAV'
              CHANGING
                xy_obj               = y_obj
              EXCEPTIONS
                cancelled            = 1
                failed               = 2
                action_not_supported = 3
                system_error         = 4
                input_error          = 5
                not_customized       = 6
                OTHERS               = 7.
            IF sy-subrc = 0.
              CALL FUNCTION 'ISU_O_METERREAD_ACTION'
                EXPORTING
                  x_okcode             = 'SAVE'
                TABLES
                  yt_eabl_delete       = xy_ieabl_delete[]
                  yt_eablg_delete      = xy_ieablg_delete[]
                  yt_etrg_delete       = xy_ietrg_delete[]
                CHANGING
                  xy_obj               = y_obj
                EXCEPTIONS
                  cancelled            = 1
                   failed               = 2
                  action_not_supported = 3
                  system_error         = 4
                  input_error          = 5
                  not_customized       = 6
                  OTHERS               = 7.
              IF sy-subrc = 0.
                COMMIT WORK.
              ENDIF.
            ENDIF.
            CALL FUNCTION 'ISU_O_METERREAD_CLOSE'
              CHANGING
                xy_obj = y_obj.
    * Implement suitable error handling here
          ELSE.
            y_return = 'E'.
          ENDIF.
        ENDLOOP.
        IF y_return <> 'E'.
          y_return = 'S'.
        ENDIF.
      ELSE
    *    RAISE no_mtr_read_ordrs_found.
      ENDIF.
    *---End of Code
    Thanks.
    Mohammed.

  • Read/write table rather than calling BAPI

    Hi experts,
    I need set "Deliv. compl." flag as true .
    set NOMOREGR='X' when call BAPI_GOODSMVT_CREATE
    I want to read/write table rather than calling BAPI, but I don't know what's the table,what's the field.
    who can tell me?  How to find that?
    I pressed "F1" key in the checkbox (Deliv. compl. flag), then I clicked "Technical infomation", and I got "MEPO1313-ELIKZ", but it's a struct, not a table.
    Many thanks.

    I happened to recall something about MEPO from way back when.... and the "EPO" suggested EKPO and EKKO to me...
    However, I utilize WHERE-USED function a lot.  For instance, in this case, one might go into SE11, enter ELIKZ into the data type field, and select WHERE-USED.  This takes a bit of research since field ELIKZ is used often as completion indicator, LOEKZ as deletion indicator, etc.
    Best wishes,
    Dave

Maybe you are looking for

  • Make adobe form -read only after Submit button

    Hi, I have an Interactive form withuser input fields. I am submitting it via E-mail.How do I make it read only after I click Submit ? I am using javscript for sending e-mail. rgds vara

  • Can I sync music from my phone to my laptop?

    My laptop broke and i lost all the songs on my itunes, however, i still have the songs on my iphone. Is there a way I can put my songs from my iphone bacak onto my computer. This is very frustrating.

  • Black Ink problems.... again....

    I'm going to be a lazy turd here and just put my problem up rather than investigate the 21 pages of dialogue that might contain the answer. So my hp 7515 grays out when I try to print in black. It will print fine the first half of a page, and by the

  • Scroll Slider for  text and image

    I have been looking to improve on a text only news scroller I have on my website and introduce one which scrolls up text with an associated image. There is one on the Goal.com website which is quite cool. It pauses too. Does anyone know of a tutorial

  • Each time i tried download on itune it tells me to contact support

    even when i tried to download a free applicztion its still request me to pay