Interface for Procurement Using Catalogs (OCI)

Hello all,
I like to have a lot of explications for this cutomizing for a flow PM.I would like call a catalog if I create order PM never pass to EBP sytem.
If I finish this customizing Interface for <b>Procurement</b> <b>Using Catalogs (OCI)</b> in R/3 system who R/3 taking all informations for a catalog when a order PM has been created.
There is a button to use a catalog if a transaction IW31 or IW32 has been executed or not?
This version SAP is ECC5.
Thanks for your response.

Hi Mady,
here are high level steps for PM/OCI:
- SPRO: Maintenance and Service Orders -> Interface for Procurement Using Catalogs (OCI) --> Define Catalogs
- SPRO: Maintenance and Service Orders -> Interface for Procurement Using Catalogs (OCI) --> Assign Catalog to Order Type
As of SAP ECC 5.00, PLM Extension (EA_PLM 500), you can call up an external catalog in a maintenance order or service order, a maintenance task list or a network, and copy services from this catalog into the order or task list or network.
You also now have the option of storing multiple catalogs for each of the following criteria:
- Order type and planning plant
- Task list category and plant
- Network type and plant
If all this customizing is OK, a little "Catalog" button will appear in maintenance or service order transaction.
Rgds
Christophe

Similar Messages

  • Interface for Procurement using Catalogs

    Hi Gurus,
    My client is implementing Punchout Catalog from SAP ECC 6.0. we are not into SRM server. I made the settings in Web services ID and Description and i am able to do shopping from Vendors URl and return back to SAP ECC.
    Now 1) they want to populate the Vendor name automatically into SAP, which is not getting carried.
             2) I want to link the Punchout Catalog to Work order scenario also. For that i need to define the Order type and Catalog in the Link "Interface for Procurement Using Catalog" under the node Plant Maintenance and Customer service which i am not getting.
    Please advice me what needs to be done or what settings or any BADI needs to be activated on this issue.
    Thanks for your response in advance,
    Thanks,
    Saakithyan.

    Hi.
    1.  I would guess that it is your vendors catalog that maps vendor ID/Name wrong. Check the source before exiting from the catalog (or add /h as hook_url parameter for test purposes)
    2. Here you need to active an extension in SPRO. I think it is EA-SCM (Activate Business Functions)
    You can also maintain the PM-catalogs, call structure etc. in the following tables without activating the extension:
    V_TMW3T Define catalog
    V_TMW03 Call structure
    V_TMW02 Assign catalog to plant and order type
    IOCI_FCONV convert HRML to SAP-fields
    IOCI_FCON2 Convert HTML Field values
    brgs Ziggy

  • Interface Project System to Catalog OCI

    I am trying to implement SciQuest within Project Systems SPRO >  Project Systems > Material > Interface for Procurement Using Catalog (OCI) and I am difficulty navigating around SciQuest site.  The actual punch out works but when I click on 'Add to Cart' an IE session opens.  Has anyone experienced this type of behavior in other catalogs?  Is there certain configuration that the vendor (e.g. SciQuest) has to adhere to since this is done directly in R/3.  I am familiar with SAP SRM which is web based and this just works, however, when I do this in R/3 it is acting as if it was web based as is not.
    Any help would be greatly appreciated.
    Kind Regards,
    Sabina McLaughlin

    I haven't worked/implemented OCI but your post made me to search some resources on this.
    Found few OSS  (mentioned below) notes related to Catalog connection and hope this provides you with some leads.
    1092900
    1092923
    Link in SAP Help.
    http://help.sap.com/saphelp_crm20c/helpdata/en/0F/F2573901F0FE7CE10000000A114084/frameset.htm
    Regards
    Sreenivas

  • SAP HR Interface for Organizational Charting (HR-OCI) 6.0

    Do you need to have a SAP portal to use HR-OCI 6.0?  Do you also need to use ESS or MSS?  We are on SAP ECC 6.0.  We currently don't have a SAP portal, but we are looking into using HR-OCI to extract the Organizational Chart for a third party vendor.  Is this still possible?
    Thanks,
      Mark

    see this might be helpful:
    SAP Human Resources - Organizational Charting Interface (HR-OCI) [original link is broken]

  • Procurement using Catalogs

    How to do Procurement using Task lists and Catalogs.

    Hi ,
    Can you pl give more detail about your problem / requirement.
    Do you want info on Task list & Catalog related to QM?
    Regards
    K.M.Arun

  • Procurement using webbased catalogs

    Hello everyone,
    we are using the OCI (Open Catalog Interface) for procurement (me51n, me21n) in an ECC 6.0 which works fine with one default catalog. Now we are looking for an solution for connecting several vendor catalogs with the SAP-system. Our options so far are:
         1) Setting up a website where you can select different vendor catalogs.
         2) Coding an selection screen which is referring to different vendor catalogs stored in customizing.
         3) Using a 3rd party application which is not really an option.
    Are there any other alternatives or best is there an SAP-standard for this problem?
    Best regards,
    Micha

    Hi Micha,
    There is very little documentation available for an OCI connection to MM. So could you please elaborate how you did set up that connection in the customizing?
    All I could find was SPRO - Materials Management - Purchasing - Environment Data - Web Services: ID and Description.
    Both PM and PS seem to offer a lot more option for their OCI integration, like assigning different catalog, converting field values etc.
    Kind regards,
    Marcus

  • Interface for Web

    Hi,
    We are using SAP BPC 7.5 NW SP08(admin and client). We have created a new user called SALES_UAT form the BPC frontend by importing the user from the Adtive Directory. We have assigned the relevant task profiles and also member access profiles to that new user. We can log-in to the Interface for Excel using that user SALES_UAT.
    But when we are clicking on the Interface for Web it is asking for the relevant username and password. We are giving Username as SALES_UAT and the relevant password. But even if we give the correct username and password it is logging into Interface for Web as BPC_SYSADMIN.
    Do we need to give other access to the new user SALES_UAT so that he can log into Interface for Web?
    Thanks,
    Appu

    Hi Appu,
    Please check if you have given correct access to the user specially in task profile. Also delete cookies and history from the internet page and try logging once again.
    Hope this works.
    Rgds,
    Poonam

  • Create OCI catalog for SRM using Web Dynpro

    Hi all,
    Have you ever implemented an OCI catalog for SRM using web-dynpro?
    Please provide details.
    Regards,
    PooYee

    Hi PooYee,
    the BSP application would run the WD catalog and communicate with SRM.
    In a certain way it would "wrap" the WD catalog application and enable accessing the http header.
    This of course is not a trivial implementation.
    Send me a mail and maybe I can give you some more ideas.
    regards, Ulli

  • How to configure one dsl connection and one public ip in cisco router and map to one interface for using exchange server

    how to configure one dsl connection and one public ip in cisco router and map to one interface for using exchange server

    Hi ,
     Have you got any additional public IP Address from your service provider , If yes on router you can have static route for those additional IP Address pointing to your ASA  outside interface . 
    Accordingly you can configure NAT 
    HTH
    Sandy . 

  • Using one Message Interface for all mappings

    Hi Folks,
    I am using a BPM in which i m getting a file from file system which have system ID in it.
    I am having three send Synchronous step following that.
    What i need is to use the Message interface for file to be used for receiver determination based on system id in case of Synchronous interfaces.
    DO i need to include this File msg. interface in each mapping, if i do so will it be possible to send req. and get response for synchronous call.
    OR is there any way to to use the file msg. interface for each mapping.
    we are on SP17,I also tried Extended mapping but i am having SYNCHRONOUS send steps.
    Plz help me out
    Sachin

    Bhavesh
    <i>1. You receiver a file in your BPM . This has a field called SYSTEM ID?
    2. On the basis of the System ID field you need to determine the Receiver to which the Synchronous Request message has to be sent?</i>
    Sorry for that...because I was confused with jai's ans.. that's why said like that
    <b>You are absolutely correct</b>
    This is what i want to do.
    i can't use switch step here.  my BPM looks like this
    RecFile->sync send->transformation1->transformation2->sync send2->transformation3->BLOCK
    in BLOCK
    Sync Send3->transformation4 and so on...
    I am using three different Sync ABS Interface for each Sync send steps.
    In receiver determination i want to get the data from respective R/3 system based on system ID i.e. logical system in File MI.
    Say if it T90CLNT90 then get data from BS_SAPR3_4.6 else from BS_4.7
    Sachin
    Message was edited by:
            Sachin Dhingra

  • Netctl: Using same ethernet interface for PPPoE and LAN

    Configuration overview
    One ethernet interface connected to a switch which has both the LAN and my ADSL router (running in bridge mode).
    My Arch PC should connect via PPPoE (possibly multiple connections) to the ISP and be able to access the LAN simultaniously. (Connection sharing is another goal, but that is not yet relevant...)
    The main reason for not changing the setup is that some other people on the LAN use their own ISP accounts over the same line.
    I currently have two netctl profiles, adsl (PPPoE) and ethernet (LAN).
    I also want the ability to run two PPPoE sessions simultaniously (with routing to determine which data uses which connection). (This is not currently relevant, but have been in the past and might be again in the future...)
    The problem:
    I'm unable to connect to both the ethernet and ADSL profiles simultaniosly.
    I tried to switch to Network manager, but it has a known bug preventing the same interface from being used for both plain LAN and PPPoE.
    The workaround that currently seem to work, is to use ifconfig to manually add an IPv4 address to the ethernet interface after connecting the PPPoE session.
    The systax for a PPP profile also have the unusual feature that its "Interface" value refers to the underlying interface, rather than the created PPP interface.
    I currently have it working on my Ubuntu HDD and previusly had it working on Gentoo.
    (Under a standard Windows XP / 7, it works with a single connection, but multiple simultanious PPPoE connections require soem non-standard tools...)
    The Ubuntu setup
    eth0 is set up by NetworkManager (I didn't have the option to avoid that one...) and I have the PPPoE connections configured in my /etc/interfaces: (ppp0 is not currently in use, was previously)
    auto lo
    iface lo inet loopback
    iface ppp0 inet ppp
    pre-up /sbin/ifconfig eth0 up # line maintained by pppoeconf
    provider dsl-provider-local
    auto ppp1
    iface ppp1 inet ppp
    pre-up /sbin/ifconfig eth0 up # line maintained by pppoeconf
    provider dsl-provider-intl
    I then have these files under /etc/ppp/peers: (with the name mathing the "provider" line) An example below. (passwords are in the /etc/ppp/*-secrets files)
    unit 0 # This specifies that the created connection uses ppp0, differs in others.
    noipdefault
    hide-password
    noauth
    persist
    plugin rp-pppoe.so eth0
    user "myuser@radius-domain"
    Arch setup:
    ADSL profile:
    Description='ISPName'
    Interface=enp4s0
    Connection=pppoe
    User='username@radius-server'
    Password='mysecret'
    ConnectionMode='persist'
    #UsePeerDNS=true
    # Override default LCP parameters from /etc/ppp/options
    LCPEchoInterval=15
    LCPEchoFailure=10
    Ethernet profile:
    Description='A basic static ethernet connection'
    Interface=enp4s0
    Connection=ethernet
    IP=static
    Address=('192.168.0.8/24')
    Solutions / Workarounds
    1. Manually configuring a IP after connecting PPPoE
    2. Not using netctl for pppoe, rather using the pppoe-setup tool
    3, Figuring out the correct netctl setup for this scenario - which is what I need your help for...
    Possibly related links
    https://bbs.archlinux.org/viewtopic.php?id=163956
    https://wiki.archlinux.org/index.php/Sh … Connection - Insists that an extra interface is needed for sharing connections - which is not a fundemental Linux requirement

    I used to use ubuntu & if you reboot into it (if you can) & run:
    $ ifconfig
    you will see eth0 & ppp1
    ppp1 will be set as the default gateway.
    Your issue in Arch is that you currently want the PPPoE interface to be the same as your LAN, this will not work at best you will need to bridge the 2 BUT I think what you should do is use the networkmanager profile as a guide & have  netctl create an adsl interface called ppp1 & set that as the default gateway
    thus:
    Description='ISPName'
    Interface=ppp1
    Connection=pppoe
    User='username@radius-server'
    Password='mysecret'
    ConnectionMode='persist'
    #UsePeerDNS=true
    # Override default LCP parameters from /etc/ppp/options
    LCPEchoInterval=15
    LCPEchoFailure=10
    I think this will work, try it & good luck
    PS:
    I do not use netctl as I use dhcp but you might even be able to configure netctl to set ppp1 as default gateway as a "post-up" command OR just create a systemd service to do it after the relevant netctl services are up
    Last edited by t0m5k1 (2013-06-18 17:56:02)

  • Tables used for Advanced Product Catalog

    Hi All,
    Can i get the tables used for Advanced Product Catalog. i.e. Catalog group and its attributes and peoples assigned and items assigned to that catalog.
    Its a bit urjent. Please help me.
    Thanks in advance.
    Regards,
    Pavitra.

    Check Note: 372415.1 - What Table Do I Use to Query For User Defined Attributes
    https://metalink.oracle.com/metalink/plsql/ml2_documents.showDocument?p_database_id=NOT&p_id=372415.1
    Electronic Technical Reference Manual (eTRM) should be also helpful
    http://etrm.oracle.com/

  • Service Interfaces for Credit Management using WS-RM

    Hi,
    We are implementing FSCM Credit Management on EHP 5 without using PI. For this we are WS-RM and have configured following service interfaces:
    CreditCommitmentNotification_In
    CreditCommitmentNotification_Out
    CreditWorthinessQuery_In
    CreditWorthinessQuery_Out
    However, when we create sales order, credit check is not being perfomed. Do we need any other service interface for implementing Credit Management?

    Hello,
    I am using ECC 6 ehp 5 Which Enables you to Implement FSCM services via WS-RM (Web Service Reliable Messaging) instead of having to use Previously PI.
    I require to implement the scenario is:
    Credit Management (FSCM) and Integration with FICA without requiring PI.
    I think I have covered all the technical configuration, but do not know how to test credit management and integration with FI-CA, appreciate if you can do to get a guide.
    As indicated by the WSRM configuration guide, run the report SRT_ADMIN_CHECK and the result is:
    Cross-checking system settings
    bgRFC destination is Operational
    bgRFC destination is registered supervisor
    WSRM event handler is activated
    Task is active watcher
    Data collector for monitoring is not activated
    ICF All nodes are active for SOAP Runtime
    Ending cross-check of system settings
    thank you for your help.
    Regards.

  • Can I use iphone in BMW via usb interface for phone call and ipod functions

    Can I use iphone in BMW via usb interface for phone call and ipod functions

    Why don't you check the manual for your car or ask your dealer?

  • CcBPM - How to use 1 Message Interface for 2 different Business System

    Hi,
    I have this bpm scenario below :
    JDBC QUERY (ASYN) ---> RFC (SYNC) -
    > JDBC INSERT (ASYN) -
    > MAIL (ASYN).
    So Both JDBC INSERT and MAIL using the same data input from RFC response for instance i will named as  MI_RFC_RES_ASYN_ABS. I have problem to configure in the integration directory, how make the xi smart enough to routing in the correct business system.
    JDBC -
    > BS_JDBC and MAIL -
    > BS_MAIL base on the send step in BPM because the interface is the same.
    Cheers
    Fernand

    Hi,
    If you want to send the same mesg to diff systems and also need to have the control on seq,
    then define 2 diff abstract interfaces for messages going out of BPM (with same message type so that structure is same).
    One will be used to define send step for JDBC and other for BPM.
    Define 2 send steps in BPM one for JDBC and other for mail using these abstract interfaces.
    Now you will have 2 receiver determinations.
    Since recr is determined based on sender system interface name and name space,
    system name ( BPM ) and name space will be same for both the messages going out of BPM.
    for JDBC abstract interface BS_JDBC will be recvr.
    and for Mail abstract interface BS_MAIL will be your receiver.
    hope it answers your qn.
    Regards
    Pushkar

Maybe you are looking for

  • Error while generating a flat file from oracle database

    i have imported three knowledge modules for the interafce. LKM SQL to SQL IKM SQL to FILE Append CKM oracle I have tried executing the interface in following ways 1. checked the staging area different from target and choosed SUNOPSIS_MEMORY_ENGINE. t

  • ITunes deleted all the music on my ipod - help!

    I purchased a fourth generation black and white screen 20GB ipod that had some music on it. I've been listening to the music for about a week without bothering to connect up to my computer. Today I installed the software that came with the ipod and u

  • Installation Hassle For Photoshop CS4

    I bought a Bamboo Fun Wacom Tablet that came with Photoshop Elements 6.0. Under Wacom's Privilege Program, I bought Adobe Photoshop CS4 for $299. http://www.wacom.com/privileges/privileges.cfm?id=55&tablet=BambooFun https://store1.adobe.com/cfusion/s

  • Using two dll or one to ensure rate

    Hi, I have a project in Veristand and the rate of the target (PXI) is 1 kHz.  Because of the specific application is easier to use two models (dll) and tu pass the output of one model(A) to the input of the other model (B). By doing that do I still e

  • How to copy a textflow?

    Dear Sirs, I need make a copy of textflow, but I'm having difficulties. I try to use the deepCopy, but it also copies the header <textflow /> , and when I insert in another textFlow, it's duplicate: var el1: FlowElement = textflow.deepCopy(); textFlo