LMS DFM - Wrong Port Alert on 3560-8 Port Switch

Hi,
there is a strange Port Util. Alert from DFM reporting High Util. on Port 1.9 which not exists on this Switch.
Beside this it reports a WS-C3560-49PS but it is a WS-C3560-8 with 8 Ports without PoE:
Here the Alert:
STATUS                  = Cleared
SEVERITY                = Informational
MANAGED OBJECT          = SWITCH
MANAGED OBJECT TYPE     = Switches and Hubs
EVENT DESCRIPTION       = HighUtilization::Component=PORT-SWITCH/1.9 [->cisco WS-C3560-48PS];ComponentClass=Port;ComponentEventCode=1057;TrafficRate=7706065.0  BYPS;DuplexMode=FULLDUPLEX;UtilizationThreshold=65;MaxSpeed=100000000;Type=E
NOTIFICATION ORIGINATOR = Fault Management Module
And here the Switch:
SWITCH#show int status 
Port      Name               Status       Vlan       Duplex  Speed Type
Fa0/1                        notconnect   4            auto   auto 10/100BaseTX
Fa0/2                        notconnect   4            auto   auto 10/100BaseTX
Fa0/3                        notconnect   4            auto   auto 10/100BaseTX
Fa0/4                        notconnect   4            auto   auto 10/100BaseTX
Fa0/5                        notconnect   4            auto   auto 10/100BaseTX
Fa0/6                        notconnect   4            auto   auto 10/100BaseTX
Fa0/7                        notconnect   4            auto   auto 10/100BaseTX
Fa0/8                        notconnect   14           auto   auto 10/100BaseTX
Gi0/1                      connected    trunk      a-full  a-100 10/100/1000BaseTX
Any idea?
Thanks
Herwig

these switches do not have a fan ...
/* Style Definitions */
table.MsoNormalTable
{mso-style-name:"Normale Tabelle";
mso-tstyle-rowband-size:0;
mso-tstyle-colband-size:0;
mso-style-noshow:yes;
mso-style-priority:99;
mso-style-parent:"";
mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
mso-para-margin:0cm;
mso-para-margin-bottom:.0001pt;
mso-pagination:widow-orphan;
font-size:10.0pt;
font-family:"Calibri","sans-serif";
mso-bidi-font-family:"Times New Roman";}
Compact Switches
Cisco Catalyst 2960-8TC-L
8 Ethernet 10/100 ports; compact size with no fan
1 dual-purpose port (10/100/1000 or SFP)
Cisco Catalyst 2960PD-8TT-L
8 Ethernet 10/100 ports; compact size with no fan
1 10/100/1000 PoE input port
Cisco Catalyst 2960G-8TC-L
7 Ethernet 10/100/1000 ports; compact size with no fan
1 dual-purpose port (10/100/1000 or SFP)
DFM uses the CISCO-STACK-MIB for the fan status; You can poll 1.3.6.1.4.1.9.5.1.2.9 to see what the switch returns. The values can be interpreted using this list from http://tools.cisco.com/Support/SNMP/do/BrowseOID.do?local=en&translate=Translate&objectInput=chassisFanStatus
1 : other
2 : ok
3 : minorFault
4 : majorFault
The reason for this could be BugID CSCsh15007 for IOS 12.2(35)SE; It is fixed in 12.2(35)SE1;
For a solution, you need to upgrade the IOS.

Similar Messages

  • Managed Ports in DFM not generating alert

    I've just added a new 3750 switch in DFM. It is in known status and the ports that I want to managed are set to TUE. However, I do not get any alert in DFM console whenever one of the managed ports go down. I have tried to delete and rediscover this device from DFM but still the same.

    I missed that you said you "typed" the shutdown command.  This won't work.  If a managed port/interface is shutdown, then DFM considers that a healthy state.  That is, the administrator has said, "this port is not being used."  No event will be generated.  To really test DFM, you need to "no shut" the port, then unplug it.  That should generate an event after about four minutes.

  • Catalyst 3560 24 port-PoE switch powers on but no STAT LED and console not responding

    I rebooted my Catalyst 3560 24 port PoE switch and when it turned on only the STAT LED went green the other LEDs are off.  I get no response from the console port using putty and the cable I used before this happened.  I tested the cable on another switch and it works fine with putty.  What can I do with this switch?

    This unit was purchased before I came to our company.  There is no support or maint contract.  I'm sure the unit is several years old...we'll call the vendor and see what they'll do..not expecting much.

  • 3560 V2 48pt Switch - second transceiver port not active

    I have a 3560 V2 48port switch that is working in a live environment and has a transceiver connected into one of the two transceiver ports and is working without issue.
    I am connecting a second fibre run to this switch. I have connected the transceiver with the fibre cable connected into the second transceiver port on the switch. However, I am seeing no activity at all. As I test I connected it into the currently working port and saw activity so I know the fibre run, fibre cable and transceiver are all functioning correctly. The issue seems to be with the second transceiver port.
    Is this a fault or is this something that needs to be configured in order to 'enable' the second port.
    Thanks,
    Seán

    If the cabling and the optics are all good, then maybe the interface is in shutdown mode.
    try this
    config t
    interface x/x (this is the interface you have the fiber connected to)
    no sh
    exit
    exit
    wr
    To verify the interface is up or down
    sh ip int brie gix/x
    If the above suggestion does not help, try crossing the fiber strands on one side of the connection.
    HTH

  • Using 3560 8 port PoE to power up 1252 dual radio AP for b\g clients

    Hi,
    We have a couple of 3560 8 port PoE switches that we plan to use to power up 1252 APs (not ordered yet). Now since the 3560 switch will only support one radio, is it possible to order a pre installed dual radio 1252 AP, disable the 5 Ghz one and enable the 2.4 Ghz, so that b/g clients can access the network, until a PoE+ switch is purchased?
    All help is appreciated
    Thanks

    Slight misconception here.  The 3560 will power the AP and both radios, so long as you are running 4.2.112.0 or higher on the WLC, or 12.4(10b)JDC or higher for an autonomous AP.  The caveat here, is you will run in a degraded state for N rates.
    The below link describes the power to N rate relationship:
    http://www.cisco.com/en/US/docs/wireless/controller/release/notes/crn421120.html#wp366903

  • PoE problem with 3560-48 port

    I am trying to power a door entry system which is 802.3af compliant (clas 3) from a 48 port 3560. It works on a 24 port version and on an HP switch but it will not work with the 48 port variant. The error log says "power Imax error". Looking at the documentation, although the switch cannot support all 48 ports at the full 15.4W, it should be able to intelligently manage power delivery to support up to 24 devices (I only need it to support 1), but this is not happening. Does anyone have any thoughts on this problem?
    Thank you.

    The cause of this Message is output in the following condition.
    1. Either IEEE 802.3af power device or Cisco power device is detected.
    2. Power is given to the device, but link is not up with (5 or 10 seconds), and power thenwill be removed and this error message is generated.
    These features have been added to Cisco IOS Release 12.1(19)EA1c .
    Ability to provide power to connected Cisco prestandard and IEEE 802.3af-compliant powered devices from all Catalyst3750-24PS, 3750-48PS, 3560-24PS, and 3560-48PS switch 10/100 Ethernet ports if the switch detects that there is no power on the circuit.

  • 3560 and legacy switches

    My IT director is considering upgrading our network with several 3560 gbic switches, however we we wondering if the gigabit ports on the 3560 would allow use to set the port speed at 100mb to attach our exsisting Intel 500 series switches?

    The SFP ports in the switch are gigabit only. But we have 10/100/1000T ports on certain models such as WS-C3560G-24TS-S/WS-C3560G-24TS-E etc which can operate at 100Mbps.

  • Im having trouble connecting my macbookpro to the tv. im using a mini display port to hdmi adapter, when i switch tv/video to hdmi on the tv nothing pops up, and i dont have the arrangement tap on the display settings, please help!

    im having trouble connecting my macbookpro to the tv. im using a mini display port to hdmi adapter, when i switch tv/video to hdmi on the tv nothing pops up, and i dont have the arrangement tap on the display settings, please help!

    I've found that the order of operations, so-to-speak, can be important when hooking up mini display port to HDMI.  I have the most success with the following operations in this order:
    1)  Plug HDMI cable into mini displayport adapter (the cable should not be plugged into either the TV or the computer at this point)
    2)  Plug the mini displayport end of your new super-cable to the computer.
    3)  Plug the HDMI end into your TV.
    4)  Switch inputs on your TV to the proper input.
    5)  If still nothing on the TV, try a different HDMI port on your TV.
    Hopefully this helps!  Good luck.

  • How do I port forward or open a port on the Airport time capsule to hook p a security system?

    I have an airport time capsule and a security system.  The installer doesn't know anything about using routers etc, especially on a mac.  They say I have to port forward or open a port specifically of this device.  I have very few skills when doing this IT type.  Is this hard to do?  Can I do it myself?  He wants to get an IT guy out?  $55 an hour, how long would it take?  Thanks in advance for anyone who can help!

    The method is here.
    AirPort - Port Mapping Basics using AirPort Utility v6.x
    If you need to get someone in, it depends.. The TC can be recalcitrant.. due to your setup of it following the apple guides.. and it depends on the security system and how simple that is.
    There are multiple issues.. for example how do you find your IP address from the web when you have dynamic IP from your ISP.
    Do you intend to setup dynamic DNS? Can the camera /dvr system handle Dynamic DNS?
    I recommend you read very carefully the instructions for what has been installed.. because merely opening the port is only a small part of the issues involved in remote access to the security system.

  • How can I write to port C and read from port A&B simultaneously using 6503 DIO-24

    I attempting to read from Port A and B which are grouped together and at the same time I want to write to Port C. The problem I having now is that every time I want to read from Port A and B, Port C seems to be effected. I have only used the easy dio's vi this may be the root of my prblem

    Hello,
    You will need to use the advanced digital VIs to accomplish what you are trying to do.
    The Easy DIO VI's are simply a combination of two DIO advanced VI, so you will use the same two advanced VI with a little different calling method. We want to call both PORT Config VI first to configure two ports for read and one port for write. Then we can simply read and write to the ports as desired, perhaps in a loop.
    The best place to start would be to look at the LabVIEW examples for Digital Input and Output operations. In LabVIEW, go to Search Examples then under I/O interfaces select DAQ (or Data Acquisition)-> Digital Input and Output->Immediate Digital Input and Output. From her you will want to look at the examples under the 8255 chip which is the chip on
    the DIO-24. I would recommend looking at Read from two digtial ports and the Write to one digital port VI's.
    From here you will simply need to combine the two together. One note: you will want to make sure that both port config VI are called before either Port Read or Port Write VIs.

  • Can i connect thunderbolt duo hard drive to the mini display port of a late 2008 macbook pro which do not have thunderbolt port, but have mini display port.

    hi, i have a late 2008 15 inch macbook pro, which have a mini display port.
    I noticed that thunderbolt and mini display port looks a like. So, my question is :
    can i connect thunderbolt duo hard drive to the mini display port of a late 2008 macbook pro which do not have thunderbolt port, but have mini display port.
    thank you

    ken94538,
    no, you’d need a Thunderbolt-to-FireWire adapter or Thunderbolt-to-USB adapter to be able to access your Thunderbolt hard drive from your 2008 MacBook Pro.

  • Web service invocation problem on host hostname and port 8000 protocol : http logical port name : LP_WS_SMDAGENT_MONITORING

    hello colleagues,
    In the phase Connect Diagnostics dont show the Agent available in SLD, but when go to SLD i have the agents,
    Error,
    Connect Diagnostics Agent
    The table does not contain any data
    Agent availables in all SLD
    SOAP:1.007 SRT: Unupported xstream found: ("HTTP Code 401 : Unauthorized")
    Web service invocation problem on host hostname and port 8000 protocol : http logical port name : LP_WS_SMDAGENT_MONITORING
    Thanks

    OK, then pls follow below steps;
    - Go to step 'Create Users' in solman_setup System Preparation scenario and make sure the user SM_INTERN_WS has a green status. Use the 'Test Login' button to make sure the user is not locked and has correct credentials maintained in solman_setup
    - Immediately after checking the user status, navigate to Configure Connectivity->Enable Web Services and execute again the 'Create Logical Ports' automatic activity, in order to propagate the correct credentials to the Logical Port definitions.
    - If the above operation is not successful, repeat the two steps above, providing a different user Id in 'Create Users' step, eg SM_INTERN_W1. This will prevent situations where the user gets locked by Logical Ports using an obsolete password.
    Let me know the results.
    Regards,
    Vivek

  • ECC6 integrated ITS default port 8000 changed to http port 80

    We want the ECC6 integrated ITS default port 8000 changed to http port 80.  The integrated ITS Cat2 transaction is currently working on http port 8000.  I changed the icm/server_port_0(Instance Profile) and the ICM Monitor Active Services(smicm – services) to use port 80.  Cat2 transaction fails http fails after system restart.  I have reverted back to 8000 and all is now working again.  Is there more work that needs to be carried out or is port 80 is supported?

    is your application server in domain?
    if its in domain and when used sapides.<xxxx>.com if you get DNS not found, may be browser is looking up internet, put your domain in the exception in tools->internet options->connection->lan settings->proxy->advanced
    "<i>This server does not support HTTPS! It is therefore potentially unsafe to send your password</i>" i just a warning message and you should still be able to log on.
    (if you want to hide this info let me know)
    <i>and i never could logon into R/3 !!</i>
    do you also see a message that SSO2 is not configured? if yes follow the steps explained in OSS note no.517860
    when you say never could logon what happens,
    a) the field for user id pwd disabled? - click on the basic authentication button to get the log on pop up
    b) error messages?
    Regards
    Raja

  • Is there a way to output a buffered pattern on port 0 and input on ports 1,2, and 3 of the 6534 card while using an external clock to vary scan rate using LabVIEW?

    I am using a 6713 board to clock my 6534 board and want to output from the buffer a patten continuously on port 0 and read from ports 1,2,and 3 at the same time and clock speed.

    Hello;
    Unfortunately, you can't combine a 24 bit group by bundling 3 ports in the same group. Valid group sizez are 8 bits, 16 bits and 32 bits only. To accomplish that task, you will need an extra 6534 board, then configure that board to do a 32bit pattern input acquisition, and discard the data from one of the four ports.
    You can definitely synchronize both 6534s with the 6713 throug the RTSI bus. To synchronize all boards together, just route the AO Update clock from the 6713 board to one of the RTSI lines, and use two more instances of the Route.vi to route from that same RTSI line to the PCLK lines of the two 6534s.
    Hope this helps.
    Filipe A.
    Applications Engineer
    National Instruments

  • USB001 Port Did not show in Port List?

    sir,
    When i want to install my printer driver, USB001 or USB002 Port did not show in port list.
    How can i install this port manually, please send me link for manual setup.
    Regards,
    Sameer Ali 

    Read the installation instructions in your printer's user manual.  Most USB printers must be connected to the computer first because they are classified as Plug-n-Play.  Once the printer is recognized you should them be prompted for the location
    of the printer software to be installed.Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread. ”

Maybe you are looking for