Measurement and Automation explorer or the Instrument I/O Assistant is not installed correctly.

I am having difficulties getting Labview to work with my NI card.  I have a PCI_6225 card running on a Win 7 64-bit install.  I had to download all of the drivers and installers from the NI site and during the Labview install, I recieve a prompt asking for my hardware drivers.  Since I only have the compressed hardware installer, Labview doesn't like what it sees and continues the installation of LABVIEW.  I then attempt to open an analog input channel through the Instrument I/O Assistant which displays the error seen in the image attached.  
I know the hardware works because in the Measurement and Automation client, I am able to observe the analog input I hope to collect in LABVIEW.  
Is there a fix to get LABVIEW working?  I have tried multple installs of LABVIEW and am on a administered computer through my University's IT people.  I have 'full admin' rights.  Thanks.
Attachments:
error.jpg ‏254 KB

Hello jbaxter,
When you download the Drivers from NI's website, make sure you unzip them (extract them) to a folder on your computer before you install them. If you use the NI Downloader it should prompt you to unzip and run the files after the download is complete. You need to either repair, or reinstall DAQmx and NI VISA. Make sure you download the latest versions of these first:
 http://search.ni.com/nisearch/app/main/p/bot/no/ap/global/lang/en/pg/1/sn/catnav:du,ssnav:sup/1//en/...
Then go to Control Panel»Programs and Features»National Instruments Software and click Uninstall/Change then go to DAQmx and NI-VISA and click Repair. You can then point to folder that you downloaded from NI's website (make sure this is not a zip folder, but the folder that has been extracted). Or you could choose Remove, and then reinstall them both again. Also if you are using GPIB, reinstall or repair the NI-488.2 driver.
Here are some relevant links:
http://digital.ni.com/public.nsf/allkb/DC808866AF7D5C0986256FCE006E9BAB
http://forums.ni.com/t5/LabVIEW/Again-I-O-Assistant-not-installed-correctly/td-p/1024807
http://forums.ni.com/t5/Instrument-Control-GPIB-Serial/quot-MAX-or-Instrument-I-O-Assistant-not-inst...
http://forums.ni.com/t5/LabVIEW/Install-Instrument-I-O-Assistant/td-p/1471516
Software Developer
National Instruments

Similar Messages

  • LabVIEW 8.5 - error: M&A Explorer or Instrument I/O Assistant is not installed correctly: what to do?

    Dear NI creators and users,
    I freshly installed the LabVIEW 8.5 and the default set of device drivers (on a new Windows XP machine), all of which I downloaded as disk images from our university central repository (we have a site-wide license). The first thing I tried to place in my first VI was the "Instrument I/O Assistant" and I got this message: "Measurement and Automation Explorer or Instrument I/O Assistant is not installed correctly. Please install these from the LabVIEW Driver CD." I tried to repair the installation, but no change. The M&A Explorer comes up fine, when I select it from the Tools menu, so I doubt, that the problem is there. Needless to say, the "Instrument I/O Assistant" throws the same error when double-clicked in the template file.
    Does anybody have a similar or the same experience? What can I do to solve this problem? Perhaps I should add that the computer with LabVIEW is intentionally not connencted to the internet, so in case the solution involves an update, I would very much appreciate some guidance to an off-line update
    Many thanks to all for any helpful remarks.
    Daniel
    Solved!
    Go to Solution.

    Hi Daniel,
    the following knowledge base contains some information how to troubleshoot: 
    http://digital.ni.com/public.nsf/allkb/DC808866AF7D5C0986256FCE006E9BAB?OpenDocument 
    Maybe you didn't install the NI-VISA or NI-488.2 driver. 
    I wish you Merry Christmas and a Happy New Year.
    With best regards 
    Ralf N.
    Applications Engineering
    Germany 
    PS:
    If that wouldn't work for you, download the latest driver-CD from our website and install it. ( It may take a while.  )
    http://joule.ni.com/nidu/cds/view/p/id/1079/lang/de 
    I'd recommend to use an USB-harddisk for transferring the files.  
    Message Edited by ralfn on 12-23-2008 02:29 AM

  • Instrument IO Assistant is not installed correctly

    Hi
    I am using LabVIEW 8.6, and I want to use Instrument I/O assistant in the code as attachment. but it shows "measurement & automation explorer or the instrument I/O assistant is not installed correctly. please install these form the LabVIEW driver CD".
    I've installed dcd-aug08-1 and could not find dcd-aug08-2.
    I tried to use "instrument I/O assistant" in another code, and it worked!?
    Please  give me some suggeation
    Thanks very much
    cynitha
    Attachments:
    Counter_Timer-Table.vi ‏134 KB

    actually I want to change the source from "simulate signal" to signal of NI USB 5132. I tried "Instrument I/O assistant" but failed.
    NI USB 5132 can run well in my laptop.
    Could any one give me any suggestion?
    Thanks
    Cynitha

  • Is it possible to change the resolution of indivdual channels in measurement and automation explorer using a VI

    Hi
    I'm acquiring data on 8 analog input channels using a PCI-6052 E card. The data on channels 5 thru 8 is going to be between +1V and -1V. So for greater resolution I'm manually changing the range of these channels to +1V to -1V in the measurement and automation explorer. Is there a way by which I can make these changes directly using a VI ?
    Thanks,
    Shiv

    Hi
    Yes you can, but only if you use the "AI Config" VI. AI config allows different gains for different channels. The "channels" and "input limits" inputs of the VI accepts arrays. The first element of the input limits array corresponds to the first element of the channel array. Check the "cont acq&chart (buffered).vi" in the LV examples. There you see what I mean!
    Regards,
    Luca

  • How do I increase the field of view in Measurement and Automation Explorer (MAX) Version 3.1.1.3003

    I am using Measurement and Automation Explorer Version 3.1.1.3003 to view pictures on a pc that are being sent from a video camera looking through a microscope.  The image I see in the viewfinder of the microscope is MUCH smaller than the image that is displayed on the pc screen.  Looking through the viewfinder of the microscope, I can see ~20 mm across the object, but the display from the camera in NI-MAX shows ~4.5 mm across the object.  How can I change how much of an object is displayed on the screen in NI-MAX?
    The camera is attached to the microscope with a camera adapter on the top of the microscope.  The lenses the camera "looks" through and the lenses used when one looks through the viewfinder are the same, so theoretically, there should be no difference in what is displayed on the pc and what is seen through the viewfinder.  We have ruled out the microscope and camera as the cause of the problem, which narrows it down to the NI-MAX software itself.
    I saw in the forums that you can zoom out on an image; however, this does not change the distance across an image that is seen, just makes the picture of the same ~4.5 mm across the object smaller in size.
    Any ideas or suggestions?

    I have attached a picture of the object's image being displayed on the pc monitor.  Where the field of view (FOV) in the microscope is almost 30 mm, the FOV displayed onscreen is about 7 mm.  After contacting companies various times I discovered there was a reducing lens that goes in the C-mount adaptor, but it is over $300. 
    I thought maybe that the FOV could be changed in in NI Measurement and Automation Exploer (NI-MAX).  Any ideas? 
    Attachments:
    field of view.png ‏2437 KB

  • Measurement and Automation Explorer not installed correctly

    I have a trial version of LabView 8.5.  Upon trying to change the Instrument I/O Assistant, I get "Measurement and Automation Explorer not installed correctly.  Please install from driver CD."  Well, I don't have the CD since this was a trial download.
    Basically, what I am trying to do is this:  I want to pull 4 variables/tags from an Allen Bradley PLC and log them to an Excel spreadsheet.  I am using RSLinx to communicate with the PLC, and LabView to compile the info. 
    Any help would be appreciated.

    Any Ideas?  I have the program running right now, and I'm kinda in a bind.  I also tried RSView32 Works to log the info, but there isn't enough flexibility in logging.  I need to log flow rate test results from a large automated machine.  The mahcine does a number of operations, but we are most concerned with these four tags (since it conducts four tests at once).  The problem is, the cycle time varies with the lot of product.  Some products require more time as the process is more delicate.  So, I can't use a time-interval logging method.
    As for variable change, I can't do that either because it records the 4 test results in series; not all at the same time.  That, and if the test is aborted (no tube), the previous test result value stays in the tag until there is a successful test.
    I found a variable that changes once per cycle.  I'd like to log the four tags once per cycle.
    BUT I can't do anything until I get the I/O Wizard working. 

  • Problems with Measurement and Automation Explorer (MAX)

    Hello LabVIEWers,
    I have been having a serious problem getting MAX to start and to remain stable. Here are the specifics:I am running LabVIEW 8.5 Full Development System on a Dell PC with 1GB of RAM and plenty of hard drive space. The OS is XP Pro and I also have McAfee Enterprise Virus Scan software.  MAX will start-up and appear to run for a few minutes and then the software bombs out. I get a "Measurement and Automation Explorer has encountered a problem and has to close" pop-up message. To fix the problem, I have uninstalled all NI software using MSI Blast. I have wiped the registry clean of NI keys as per instructions in previous posts. I have deleted any remaining NI software on teh hard drive including C:\program files\national instruments and C:\Documents and Settings\All Users\Application Data\National Instruments. I have then restarted the machine and did a complete fresh install from CD's, DVD's, and the harddrive (CD's written to hardrive and DVD written to harddrive first). I installed first the LabVIEW and then I installed the Device Drivers. I restarted the machine between installs. I have even installed the updated NIDAQ 8.6. After which I set protections on the NI directories to read/write. Ok, basically I have done all these things numerous times and I still cannot get things to work correctly.
    I was able to get into MAX for a little while (it is somewhat stable immediately after a fresh reinstall). I defined 4 Simulated DAQmx devices and none of them acted like they were simulated. I received various errors saying that the device was not found or could not be started. So I basically could not run my software with the simulated devices. LabVIEW sometimes seems to work ok but just now, I got a "Error loading nidmm_32.dll, initialization routine failed" error. I also get the same error for nilvaiu.dll. Both of these DLLs are in the C:\Program Files\IVI\Bin and  c:\windows\system32 directories respectively and prior to the last time I started the software, all worked ok with LabVIEW.
    Is my computer failing? Are there any other options to getting this installed without probems?
    Please help.
    Michael Froehlich

    Duplicate Post
    Keep discussion here
    National Instruments
    WSN/Wireless DAQ Product Support Engineer

  • Error -2147220733 occurred at DAQ Assistant (in Measurement and Automation Explorer)

    Ok!  Just before the weekend I figured out how to make channels in Measurement and Automation Explorer for inputs through a couple different NI input devices (USB-9211A & PCI-6229 DAQ).  Things were going well.  Loaded up the computer today, added a few more channels.  Worked fine.  Now all of a sudden, any channel I make has an error and if I try modifying existing channels and saving, I get same error:
    "This global channel currently has an error.  You can save the global channel, but it cannot be used until all errors have been fixed.  Press "Yes" to save anyway, or "No" to cancel and show the error."
    If I hit yes, the channel is non functional.  After hitting no, I get:
    "Error -2147220733 occurred at DAQ Assistant.  Possible Reason(s): "
    with no possible reasons listed.  I tried restarting the program.  I tried restarting the computer.  I verified connections.  Searched for the above stated error number on ni.com, google.ca, and in the MAX help files, and found absolutely nothing.  I have no clue what to do.  Any help would indeed be very much appreciated.

    Hi there,
    This is my first time on here and I've only been using this software for a couple of days so it's possible I'm making a trivial error but I thought I'd post here anyway as I can't find anything on the net about my problem.
    I also get an error while trying to save:
    Error -2147220733 occurred at DAQ Assistant
    Possible Reason(s):
    Requested Code: -2147220733
    But mine comes about in different circumstances to the one in the original post on this thread by Kahless. I was editting a VI logger task and within that I was trying to edit an NI-DAQmx Task. I was trying to change the clock settings, specifically I was attempting to change the Rate (Hz) from the 1k default to just 20, or 200. I got the error while trying to save so changed it back to 1k, but the error persisted even though I'd set it back to what it was.
    I thought at first it might be simply that I was trying to edit an NI-DAQmx task within VILogger, so I tried making the ammendment directly but the problem was still there. 
    Any ideas?
    Many thanks.

  • Error 70025 in Measurement and Automation Explorer

    After a clean reboot of the system I receive Error -70025 ("Return Buffer is not empty..") in the Measurement and Automation Explorer. When I click on "Clear RDB" which is supposed to solve the problem, it says "Error clearing the return data buffer". In the status tab, all LEDs are flashing (Error Code varying from 0xFFFF to 0x0182).
    First, I simply tried to remove the motion controller (it's a NI PCI-7334) from the MAX tab which did not work. Then, I tried to repair the installation of all NI tools but this didn't help either.
    I'm working with NI Motion 8.4 and MAX 5.4.0f0 on Windows XP.
    Do you have any idea how to solve this problem? Currently, I cannot run the motor at all.
    Thanks,
    Jürgen
    edit: I just realize that the controlller is listed as PXI-7334 in the Windows Device Manager but in fact it is a PCI-7334. Would this explain the problem?
    update: Forcing the installation of the PCI-334 driver does not make any difference.

    Hi Jürgen,
    you can find the description of occurence and solution for this error here.
    Please try it.
    When it dosen't solve your issue please contact me again.
    Kind Regards,
    Philipp K.
    Applications Engineer | NI-Germany

  • Measurement and Automation Explorer does not recognize two identical USB 3.0 cameras at once. How do I fix this?

    I am running a set up which uses 2 identical USB Point Grey cameras of the same model (FL3-U3-13S2M-CS). Both USB cameras are plugged into the computer (blue USB cables). 
    When I open up Measurement and Automation Explorer and look under "NI-IMAQdx Devices" in the configuration tree, LavVIEW only recognizes one of the two USB cameras. Measurement and Automation Explorer only lists one camera, in which it recognizes it as "Point Grey Camera". Why this is occurring? How can I get LabVIEW to recognize two separate cameras of the same model? 
    Attachments:
    PointGreyCamera.JPG ‏2847 KB
    DualUSB.JPG ‏2932 KB
    MeasurementAutomationExplorer.JPG ‏99 KB

    That's about the old NI-IMAQ for USB cameras. IMAQdx has built in support for DirectShow connected cameras. IMAQdx should be able to use more than one DirectShow camera at the same time, but the Point Grey DirectShow driver may have some issues.
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Parallel port not detected in measurement and automation explorer

    I have installed labview 2010 in windows XP.
    The problem what I am facing is I could not find "Serial & Parallel port" option in Measurement and automation explorer.
    After seeing the similar problem in forum I have installed Ni-Daqmx 9.0.2.  But still I can not see the ports in MAX.
    I think i have attached enough document .
    If the parallel port is not detected in MAX can we send digital data to parallel port.
    I have tested parallel port with LED connecting one leg in 1st data line(pin 2) and another in gnd(pin 25).
    And my program is to blink the led for every one second but I cannot see the blinking.
    Can anyone help in this regards
    thank you
    Attachments:
    max.jpg ‏90 KB
    port setting tab1.jpg ‏30 KB
    device manager resource tab.jpg ‏34 KB

    Thank you for ur reply Smercurio
    I have changed the bios setting now 
    but still i cant see the printer port in MAX
    Regarding my vi, now i changed it please see that also 
    I have given values to element of arrays as (1,2&4) 
    Now also it is not blinking instead it is glowing all the time without blinking.
    What i have to do next.
    Attachments:
    device manger.JPG ‏43 KB
    device manger2.JPG ‏165 KB
    port test.vi ‏9 KB

  • I can't find my PCI card using Measurement and Automation Explorer

    I've installed the PCI card.. It's a PCI-DAS08. The PC I'm running is quite slow, took like an hour to install Labview. The Measurement and Automation Explorer can't seem to find the card even though it's shown in the Device Manager. I don't know how to solve this problem. Any help or tips appreciated. THANKS

    Is tha device made by NI?
    MAX only supports NI DAQ devices.
    You will need the drivers and support software from the equipment manufactuer.
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Hello.  Since accepting the upgrade to the current version of I Tunes (11.4) I have been unable to get the application to boot.  I receive the message that I Tunes was not installed correctly and Error 7 (Windows Error 193).

    Hello.  Since accepting the upgrade to the current version of I Tunes (11.4) I have been unable to get the application to boot.  I receive the message that I Tunes was not installed correctly and Error 7 (Windows Error 193).  I have uninstalled/reinstalled I Tunes several times and this has not resolved the issue.  I also uninstalled/reinstalled Microsoft.net Framework 4 since this was suggested by Apple support.  This also has not resolved the issue.
    When I reinstall I Tunes, I get a message that the “Service ‘apple mobile device’ failed to start.”  Verify you have sufficient privileges to start system services.  I attempted to manually start the Apple Mobile Device service but get a pop up stating, “Error 1053: The service did not respond to the start or control request in a timely fashion.”Unsure what I should try next. 

    For general advice see Troubleshooting issues with iTunes for Windows updates.
    The steps in the second box are a guide to removing everything related to iTunes and then rebuilding it, which is often a good starting point unless the symptoms indicate a more specific approach. Review the other boxes and the list of support documents further down page in case one of them applies.
    Your library should be unaffected by these steps but there is backup and recovery advice elsewhere in the user tip.
    The section Install missing components has advice on breaking down the iTunes installer into the individual .msi files which might prove useful if one component, such as Apple Mobile Device Support, won't install normally.
    In your case I suggest you start with a clean download of the setup file using the direct link. If reinstalling AMDS alone doesn't work try tearing everything down again.
    tt2

  • Itunes was not installed correctly error 1114.  I have uninstalled and reinstalled using the steps several times., itunes was not installed correctly error 1114.  I have uninstalled and reinstalled using the steps several times.

    itunes was not installed correctly error 1114.  I have uninstalled and reinstalled using the steps several times., itunes was not installed correctly error 1114.  I have uninstalled and reinstalled using the steps several times.
    I have never been so close to packing the whole lot up and sending the ipad back!
    Please help!
    Kieran

    Issues installing iTunes or QuickTime for Windows
    iTunes 11.1.4 for Windows: Unable to install or open
    Troubleshooting issues with iTunes for Windows updates

  • I have uninstalled and reinstalled iTunes multiple times.  When I connect my iPod Classic I get the following message:  The software for this iPod is not installed correctly.  Please reinstall iTunes to install the required software.  Any ideas?

    I have uninstalled and reinstalled iTunes multiple times.  When I connect my iPod Classic I get the following message:  The software for this iPod is not installed correctly.  Please reinstall iTunes to install the required software.  Any ideas?

    Assuming you have windows, try uninstalling iTunes and all of its components as by following this guide exactly: Windows XP or Windows Vista/7, then reinstall iTunes.  You must follow this guide exactly or it will not be successful.  Note: uninstalling iTunes will only remove the application; it will not touch your iTunes library or data.

Maybe you are looking for

  • Ethernet configuration with SMC router and Titanium

    This concerns a Titanium Powerbook G4/500 and an SMC 2804WBR router. I plugged in a known-working Ethernet cable, and in System Preferences/Network, under Network Status for Built-In Ethernet, I got the message "The cable for Built-In Ethernet is not

  • WRVS4400N Quickvpn Trouble

    I have been using QuickVPN to connect through my WRVS4400N to a RV042 for several weeks. It then stopped connecting. After troubleshooting -> problem hardware is the WRVS4400N. I re-flased the current firmware and double checked all configurations. Q

  • RE: Statistics in the ORacle 10.2.0.4

    Hello, As we know we can gather the statistics of a table/schema throw the "DBMS_STATS" package, how to monitor(how much% has completed,timeelapsed,how much time remains) these kind of jobs. I know about the below way, can we do it in beter way, SQL>

  • Generating dynamic Attachments between bpel process activities

    Dear Experts, Please suggest me that how to handle dynamic attachments in BPEL process with JDeveloper. The requirement was need to send an attachment between activities in same BPEL process and not sending an attachment through mail. For Instance co

  • A question about sst sample driver

    I have checked the Solaris 8 version of sst SCSI sample driver. There is one thing I couldn't understand: In the definition of sst_fill_cdb, sstprivp->priv_amt is used as transfer length. This variable is set to bp->b_bcount - pkt->pkt_resid in sst_m