METER READING STATUS PROBLEM

I have a quick question friends...As we create the billing order it has a status field in EABL that is ABLSTAT.. now i ahve invoiced  ameter read and its still showing its status in EABL as 1 like all the invoiced meter read has status 1...but if i go and see the meter ead status in EL31 it shows me 7 which it drives tthrough a funciton module 'ISU_reading_status******'  So is it a configuration errror that status in EABL doesnt not get updated ...if so what can be solution for this.....

Hello,
Additionality there is some information available in the Wiki on this topic..
http://wiki.sdn.sap.com/wiki/display/UIndustry/MeterReadingStatus
Regards
Olivia

Similar Messages

  • What is Meter reading validations (System defined & User defined)

    Hi Experts,
    1 )How to configure Meter Readings (Technical Control Parameters, MR Control, MR Notes etc)
    2) what is Meter reading validations (System defined & User defined) and how to configure it.
    3) What is Register Relationships,Device Groupings & Device Allocations and how to configure.
    Kindly explain with examples.
    Thanks in advance.
    Regards,
    Shabnum

    hi,
    Meter Validation Steps:
    1.     The Validation Process begins with Meter Reading Order Creation when the expected consumption is determined for the meter reading to be recorded for each register. The meter reading status is u201C0u201D or un-entered at this time.
    2.     The meter reading is entered via an upload program as part of the batch processing or entered manually.
    This result is validated or evaluated against the permitted range of allowable meter reads/consumption for that register.  The expected consumption is the basis for determining the range of the minimum and maximum values for the meter reading.
    If the result is plausible, or valid, for all registers of the meter, the billing order becomes billable and the contract/installation is passed to billing for further processing. The meter reading status is updated to u201C1u201D or billable.
    If the meter reading is validated as implausible, the meter reading result is transferred to the List of Implausibles for further processing (EL70). The status of the meter reading is u201C2u201D or automatically blocked. One or more independent validations can be failed in this validation process.
    3.     During processing, the agent can release the meter reading for billing; the status is updated to u201C4u201D, released by clerk. The reading is accepted as measured. The agent can also process the implausible meter reading result using transaction code: EL27 Execute Correct Implausible Meter Reading Results. EL27 is recommended for individual processing.
    SAP Easy Access  Utility Industry  Device Management  Meter Reading  Correction of Meter Reading Results  Implausible Results (Transaction EL27)
    EL70 is recommended for processing of implausibles for mass processing.  It is not on the menu, however, one way to open the screen is:
    SAP Easy Access  Utilities  Device Management  Meter Reading  Correction of Meter Reading Results  Implausible Results
    Once the screen opens, click on the List button on the application toolbar
    4.     The agent may also correct the meter reading. If this corrected read is validated as within range, the status is updated to u201C1u201D, billable.
    5.     Alternatively, the reading can be determined to require follow up action and a service order is executed from the IC for re-read. A read status has been configured to support this flagging of the account for follow-up service order processing.
    6.     When the service order is returned from the field, the CSR releases corrects, resets or possibly estimates the meter reading depending on the outcome of the service order processing.
    7.     The meter reading is then passed to the billing engine for billing execution when the reading is validated as plausible.
    -Siva

  • Implausible meter reading flag-table/field

    Hi
    Is there any flag goes into the DB against implausible meter reading against any business/technical master data, please specify the table/field if known.
    Gaurav Upadhyaya

    Hi Gaurav,
    As mentioned above, the field ABLSTAT (Meter Reading Status) in table EABL would let you know if a meter reading is plausible or not. The values of implausible meter reads are:
    2     Automatically Locked
    3     Locked by Agent
    U can reach the table EABL as follows:
    ANALAG (installation) using tables EABLG by getting the meter read doc no.
    Hope this helps
    Thank you,
    Binno Don Thomas

  • Hyperion Smart View meta read problem

    hi
    I created a template for users in smart view.I was testing with some native users.
    the template which i created was with all the dimension and I Descendants dimensions.
    some users are having write back functionality.
    i used Meta Read filters for some users who will be only having access to a particular dimension and member.
    At first i created a template with all the dimension and descendants and did save the report and I logged in with native users in to the same template.When i click on member selection I am able to see the applied filter( Meta Read) is working properly.But by default when i login with the same user at first i am getting an message saying that for some members you are are not having permission upto there i am fine.
    My question is
    Is there a better work around.So that when the user logs in smart view the template which provided he should only see the members for which he is having permission and the rest of members for which he is not having permission should disappear.
    Thank in Advance
    Thanks
    Kris
    Edited by: user9363364 on Mar 30, 2010 1:08 PM

    You most likely have a SV template set up and are trying to share that template, correct? The functions are looking for the SV xla in the bin folder, so if SV is installed in different paths, then your SV template will produce that error. When you first open the template and you get the update links, select edit, then browse to where the user has SV installed and go to the bin folder. This should update those functions.

  • Error while uploading meter reads through BAPI_MTRREADDOC_UPLOAD

    Hi,
    I am trying to estimate and upload meter reads on an installation through function module ISU_REGISTER_ESTIMATE and BAPI_MTRREADDOC_UPLOAD respectively. The output estimated read from ISU_REGISTER_ESTIMATE is fed to BAPI_MTRREADDOC_UPLOAD after removing decimal places, comma etc.
    While this works perfectly each time, there is one instance where this arrangement is not working. If the previous read is too large ( and plausible), in certain cases BAPI_MTRREADDOC_UPLOAD fails to upload the next read and gives an error with error description 'Format of MR 17737 not valid (MR document number 105677 ) '.
    As I said, both the function modules are workinf fine most of the times. However at certain instances it ends up with this error. Anyone encountered this problem before?
    All suggestions are welcome !
    Thanks in advance,
    AM

    Hi,
    Message - 'Format of MR 17737 not valid (MR document number 105677 ) signifies that number of pre-decimal places and number of post decimal places do not match with your register group configuration.
    Since, you are suggesting that your logic works in most of the cases, I think when meter overflow happens and while you are converting it to actual read - this reading do not match with pre-decimal and post decimal places.
    You need to double click on register group for a device, where you are facing this issue and then compare your calculated read in your code.
    Hope this helps.
    Regards,
    Avinash

  • Automatic creation of meter reading order with RR 01 after move in

    Hi Experts,
    I am working with DM module of SAP ISU. Currently I am facing a problem that after move-in a periodic order with RR 01 is created automatically by the system.
    Ex: Move in date is 01.01.2010. Monthly Portion is used with Schedule record 01.01.2010, 01.02.2010, 01.03.2010, 01.04.2010 and so on.
    If current system date is 20.07.2010 then Meter reading order is created automatically by the system for sch MRD 01.08.2010.
    Please let me know how to overcome this problem
    Thanks in advance.

    Thanks for your reply but I have cheked SPRO setting the suggested check box is already uncheked.
    I beleive the setting you have suggested is meant for default meter reading during move in but my problem is automatic creation of meter reading order with reason 01 during move in

  • Mails trun automatically to read status

    Dear All ,
       We are facing one problem in our mail sender adapter. sometimes the mails in inbox  turn as read from unread status automatically.   We don't know what is the exact resaon. We are using IMAP protocol. Please Help us
    Regards
    Xi User

    This could happen when there is some problem in reading those mails. At that moment, for imap cases, the mail is changed to Read status but is not processed. Could you see any error at that time in Communication channel monitoring. Also have a look at SAP Note 1241039.
    Regards,
    Prateek

  • "Read" status of e-mail will not sync wirelessly between Lotus Notes and 8520??

    HI,
    This is my first post and I realize that this might not be the right area to post this question but my question did not seem to fit anywhere else.
    I was recently issued a BB 8520 at my new company and we work in a Lotus Notes environment and I believe it is version 7.
    This is not happening to anyone else that I know of in our company but when I read an e-mail in Lotus Notes from my desktop, wireless sync will not mark it read on my Blackberry. Also when I read an e-mail on my BB, it will not mark it read in Lotus Notes. However if I delete an e-mail in Lotus Notes, it will delete it from my BB via wireless sync. Finally, when my BB is attached to my desktop via USB, and I do a manual sync from Blackberry Desktop Manager, it will sync the "read" status of my e-mails between Lotus Notes and my BB.
    So I guess my question is why are most sync functions working via wireless sync between my e-mail in Lotus Notes and my BB, but not the "read" status of an e-mail? And I know that it works for other users in our company so it's really bothering as it is a whipping to have check e-mails that are still marked as unread (in both Lotus Notes and my BB) when I have already read them.
    Thank you and I would really appreciate any help or information that I could provide to our IT Admin at work to help him solve my problem.
    Thank you,
    Matt

    Hi and welcome to the forums!
    Looks like you posted in the right device forum and your post is very clear!
    First open the main message queue, menu key options, email reconciliation, is wireless reconcile on?
    Some "light reading" that may address the issue as well is attached below.
    Let us know how it goes!
    Thanks,
    Bifocals
    Unread marks synchronization is inconsistent between BlackBerry smartphone and IBM Lotus Notes
    Click Accept as Solution for posts that have solved your issue(s)!
    Be sure to click Like! for those who have helped you.
    Install BlackBerry Protect it's a free application designed to help find your lost BlackBerry smartphone, and keep the information on it secure.

  • VISA Read function Read buffer problem in serial communication

    Hi,  I use VISA write and read function in serial communication app, the device continuously sends 0x00 if it is not receive a request from Labview program running on PC.
    And the request sent by labview is programmable. I met a weird problem, each time the request changes, the VISA read buffer output port still shows the last request firstly, from second time, shows the right request.
    It works like: Req code: ... 50, 51,51,51,50....;  VISA Read buffer: ...50, 50, 51, 51, 51, 51, 50....
    Please refer to the program.
    Attachments:
    readOne_test.vi ‏21 KB

    How are you running this?  You don't have a while loop around it.  Is it part of a larger VI?  Please don't tell me you are using the run continuously button.
    You don't have any wait statement between you VISA Write and your bytes at port.  So it is very likely the receive buffer is still empty since you didn't give your VI time to wait for the device to turn around and give a reply.  If you read 0 bytes, your VISA read string will be empty.  How does your decoder subVI (which you didn't include) handle an empty string?

  • Meter Reading date – estimating EL30

    Morning,
    Do you know how can I change the meter reading date when I run the estimation process through transaction EL30?
    See the problem.
    This customer has a custom estimation development. But, I see that meter reading date in the estimation enhancement is set with the scheduled meter reading date.
    However, I would need to change this date to the system-date when the estimation is triggered through tx. EL30.
    Is there any enhancement before the estimation module, to change the meter reading date automatically?
    Thanks.

    Hi,
    use function module ISU_DB_TE418_SELECT_DAT_TUR_NX or ISU_DB_TE418_SLCT_N_ADATSOLL_T for the next date and ISU_DB_EANL_SINGLE_ALL_TS to get the MRU of the installation first.
    KR
    Uwe

  • Meter reading in IFCU

    Hi Experts ,
    I am facing one problem while entering the fuel consumption along
    with the Meter reading in IFCU.
    In IFCU , system allowes me to enter the fuel comsumption but the Kilometer
    entry field is gray.
    I checked all the custamisation setting ....
    Plz tell me , if i missed out some thing.
    Thanks in Advance

    Hello Dear
                   have u defined measuring position in measuring points , and same in spro in fleet managment
    Jitender

  • Creation of Meter Reading Order

    Hi,
    My uploading program creating Meter Reading order using the function module ISU_S_METERREAD_CREATE. MRO is created Successfully for Meter Reading Reason 06. The Problem is Metering scheme is not Displaying in the Table EANL for the particular Subinstallation.
    Any one help me pls.
    Thanks in Advance
    Lakshmi

    Hi,
    Use Blocking Reason in ES31 (installation: Billing/Meter Reading control Tab)...During meter reading order creation, prevents meter reading orders from being created for the registers allocated to the installation.

  • Read Status does not apply correctly when working out of a shared mailbox.

    since updating to the Exchange 2010 SP3 RU4, users have been experiencing the same issues when working out of shared mailboxes. when user 1 opens an email or manually marks the email as read the status does not change from their perspective, the email remains
    unread. however, the other users viewing the shared mailbox immediately see the status change to read. User 1 has to re-sort his email from catagory to received or from ect. As soon as the emails are resorted the status changes. alternatively, if User 1 views
    another folder and returns back. the email is marked as read.
    This problem happens with Outlook 2007 and 2010
    This happens after re-creating the profile
    opening outlook with the switches /cleanprofile /cleanviews seems to solve the problem for an hour or so.
    I have run mailbox repairs on the server for the mailboxes in question.
    changing the behaviour in tools>options>reading pane> has no effect.

    Hi Brenn,
    To narrow down the issue, we need more investigation:
    1.Does the issue occurs only in Category view? Please check if user 1 set the view to Date and email read status update.
    2.Does the issue occurs to user1's own mailbox with the same setting as shared mailbox?
    3.If the shared mailbox is in cached mode, please check Account Settings > Change > More Settings... > Adwanced > Use Cached Exchange mode > check Download shared folders.
    4.Please switch to online mode for shared mailbox and test the issue.
    Regards,
    Rebecca Tu
    TechNet Community Support

  • Mail does not correctly reflect read status of Gmail IMAP messages

    Apple Mail is no longer correctly reflecting the read status of emails that have been read on other devices/computers when viewing my Gmail IMAP inbox. Whereas my iPhone and Gmail account both show changes in items' read status immediately or on next mail retrieval, in Apple Mail the only way I have currently of updating the read status is to quit Mail and restart it. Neither automatic fetching of Mail, nor clicking "Get Mail", nor right-clicking the Inbox and choosing "Synchronize Gmail" work.
    My other IMAP account (MobileMe) does not exhibit this behaviour, but Mail.app does this with Gmail on both of my desktop computers.
    Anyone out there with a similar problem? And are there any possible solutions, or is it a bug/incompatibility with GMail?

    This problem is still occurring for me in 10.5.5 - I even tested it by creating a new gmail account with only 1 message in it, in case it was a problem with large mailboxes, and the same thing happened.
    Mail messages marked read elsewhere are not updated in Mail on the next send/receive. I wonder if everyone with this problem could report the bug at http://www.apple.com/support/feedback and see if we can get this solved in 10.5.6

  • DM - Meter Reading Workflow functionality

    Hi all,
    I have a customer's requirement that the estimated MR should be "corrected" automatically in case the next actual MR arrives and it is less then the estimation done before.
    Can anybody help me via the customizing and the development (if any required)?
    I have found the Customizing section Define Automatic Monitoring of Meter Reading Data, that works in co-operation with the function module EXIT_SAPLEL01_020, but I am not sure if this is the recommended way of solving this problem.
    Thanks in advance for your feedback, regards,
    Bou.Lis

    Hi Bou.Lis,
    Standard SAP Triggers the event ASSESSED in the Business object - ISUCONTRCT.  Use this to assess the meter reads and estimate the reads.
    Obviously you may also need to cancel the billing documents if you are adjusting the meter reads for the period billed. In that scenario you can use BILLDOCAUT -> BDOCSFORREVERSAL and BILLDOCAUT -> ADJREVERSETAB.
    For re-estimation you can leverage using the FM ISU_ACTION_ASSESSING. This FM estimates for all the registers, so you might want to customize and re-estimate only for implausible meter reads registers.
    I would recommend working with a solid workflow developer who has IS-U knowledge.
    Hope this helps.
    Sai

Maybe you are looking for